4
Features Surface Omega-type seal Movement High movement capacity ASTM E-1399 Class I: Thermal Class II: Wind Class III: Seismic Omegatec 1300 : A01 SEAL EXPANSION JOINT Concrete to Concrete | Steel to Steel 50 - 250 mm ( 2 - 10” ) Expansion Gaps System Options Gap width(s) 50, 80, 100, 140, 200, 250 mm Height(s) 13, 18 mm Metal type(s) Galvanised Steel clamping system Colour(s) Black Fire barrier 120-240 minutes Waterproofing Max. water pressure 1.75 MPa Pre-assembly in factory Contact Vexcolt Traffic Frequency per day - - - - - www.vexcolt.com APPLICATIONS Immersed Tunnels Bored Tunnels Aqueducts Roads & Bridges Submersed Structures VEXCOLT | United Kingdom | T : +44 (0) 1752 894133 | E : [email protected] | W : www.vexcolt.com

Transcript of SEAL EXPANSION JOINT - Vexcoltvexcolt.com/pdf/omegatec1300/omegatec_1300_a01.pdf · SEAL EXPANSION...

Page 1: SEAL EXPANSION JOINT - Vexcoltvexcolt.com/pdf/omegatec1300/omegatec_1300_a01.pdf · SEAL EXPANSION JOINT ... Seal Fully Open Seal Fully Closed Height Stud Fixing Radius Width Number

Features

Surface Omega-type seal

Movement High movement capacity ASTM E-1399 Class I: Thermal Class II: Wind Class III: Seismic

Omegatec 1300 : A01

SEAL EXPANSION JOINT Concrete to Concrete | Steel to Steel

50 - 250 mm ( 2 - 10” ) Expansion Gaps

System Options

Gap width(s) 50, 80, 100, 140, 200, 250 mm Height(s) 13, 18 mmMetal type(s) Galvanised Steel clamping systemColour(s) BlackFire barrier 120-240 minutesWaterproofing Max.waterpressure1.75MPaPre-assemblyinfactory ContactVexcolt

Traffic Frequency per day

- - - - -

www.vexcolt.com

APPLICATIONS

Immersed Tunnels

Bored Tunnels

Aqueducts

Roads & Bridges

Submersed Structures

VEXCOLT | United Kingdom | T : +44 (0) 1752 894133 | E : [email protected] | W : www.vexcolt.com

Page 2: SEAL EXPANSION JOINT - Vexcoltvexcolt.com/pdf/omegatec1300/omegatec_1300_a01.pdf · SEAL EXPANSION JOINT ... Seal Fully Open Seal Fully Closed Height Stud Fixing Radius Width Number

VEXCOLT | United Kingdom | T : +44 (0) 1752 894133 | E : [email protected] | W : www.vexcolt.com

Omegatec 1300 : A01

SEAL EXPANSION JOINTConcrete to Concrete | Steel to Steel

50 - 250 mm ( 2 - 10” ) Expansion Gaps

Joint Gap Movement Water Pressure Product Dimensions Product

Location Width Capacity (mm) Seal Fully Open Seal Fully Closed Height Stud Fixing Radius Width Number

B (mm) ± [Total] Mpa Mpa H1 (mm) (mm) A (mm) C (mm)

Concrete-Concrete Steel - Steel

50 +40/-30 [70]0.75 1.75

13M24

25 210 1300-A01-050

80 +60/-40 [100] 40 240 1300-A01-080

100 +70/-50 [120]0.50 1.20

50 260 1300-A01-100

140 ± 70 [140] 70 300 1300-A01-140

200 ± 90 [180] 0.30 0.80M30

100 360 1300-A01-200

250 ± 100 [200] 0.25 0.75 18 120 410 1300-A01-250

Expansion Joint Selection Criteria Load Rating Product Details

Page 3: SEAL EXPANSION JOINT - Vexcoltvexcolt.com/pdf/omegatec1300/omegatec_1300_a01.pdf · SEAL EXPANSION JOINT ... Seal Fully Open Seal Fully Closed Height Stud Fixing Radius Width Number

20

0.20

0.00

0.40

0.60

0.80

1.00

1.20

1.40

1.60

1.80

2.00

30 40 50 60 70 90

GAP WIDTH (mm)

NominalGap Width

NominalGap Width

WA

TER

PR

ESSU

RE

(Mp

a)

80 40

0.20

0.00

0.40

0.60

0.80

1.00

1.20

1.40

1.60

1.80

2.00

50 60 70 80 90 110 120 130 140

GAP WIDTH (mm)

WA

TER

PR

ESSU

RE

(Mp

a)

100 50

0.20

0.00

0.40

0.60

0.80

1.00

1.20

1.40

60 70 80 90 100 120 130 140 150 160 170

GAP WIDTH (mm)

WA

TER

PR

ESSU

RE

(Mp

a)

110

70

0.00

80 90 100 110 120 140 150 160 170 180 190 200 210

GAP WIDTH (mm)

WA

TER

PR

ESSU

RE

(Mp

a)

130 110

0.10

0.20

0.30

0.40

0.50

0.60

0.70

0.80

0.90

0.00

120 130 140 150 160 180 190 200 210 220 230 240 250 260 270 280 290

GAP WIDTH (mm)

WA

TER

PR

ESSU

RE

(Mp

a)

170 150 160 170 180 190 200 220 230 240 250 260 270 280 290 300 310 320 330 340 340

GAP WIDTH (mm)W

ATE

R P

RES

SUR

E (M

pa)

210

0.20

0.40

0.60

0.80

1.00

1.20

1.40

0.10

0.20

0.30

0.40

0.50

0.60

0.70

0.80

0.90

0.00

NominalGap Width

NominalGap Width

Min.Gap Width

Min.Gap Width

Min.Gap Width

Min.Gap Width

Max.Gap Width

Min.Gap Width

Min.Gap Width

Max.Gap Width

Max.Gap Width

Max.Gap Width

Max.Gap Width

Max.Gap Width

NominalGap Width

NominalGap Width

SEAL EXPANSION JOINTConcrete to Concrete | Steel to Steel

50 - 250 mm ( 2 - 10” ) Expansion Gaps

Omegatec 1300 : A01-050 Omegatec 1300 : A01-080 Omegatec 1300 : A01-100

Omegatec 1300 : A01

Water Pressure Capacity vs Seal Movement Range

All Omegatec 1300 : A01sealsareformedwiththreelayersofnylonreinforcementasstandard. TheminimumwaterpressureFactorofSafetyis3.0.

VEXCOLT | United Kingdom | T : +44 (0) 1752 894133 | E : [email protected] | W : www.vexcolt.com

Page 4: SEAL EXPANSION JOINT - Vexcoltvexcolt.com/pdf/omegatec1300/omegatec_1300_a01.pdf · SEAL EXPANSION JOINT ... Seal Fully Open Seal Fully Closed Height Stud Fixing Radius Width Number

20

0.20

0.00

0.40

0.60

0.80

1.00

1.20

1.40

1.60

1.80

2.00

30 40 50 60 70 90

GAP WIDTH (mm)

NominalGap Width

NominalGap Width

WA

TER

PR

ESSU

RE

(Mp

a)

80 40

0.20

0.00

0.40

0.60

0.80

1.00

1.20

1.40

1.60

1.80

2.00

50 60 70 80 90 110 120 130 140

GAP WIDTH (mm)

WA

TER

PR

ESSU

RE

(Mp

a)

100 50

0.20

0.00

0.40

0.60

0.80

1.00

1.20

1.40

60 70 80 90 100 120 130 140 150 160 170

GAP WIDTH (mm)

WA

TER

PR

ESSU

RE

(Mp

a)

110

70

0.00

80 90 100 110 120 140 150 160 170 180 190 200 210

GAP WIDTH (mm)

WA

TER

PR

ESSU

RE

(Mp

a)

130 110

0.10

0.20

0.30

0.40

0.50

0.60

0.70

0.80

0.90

0.00

120 130 140 150 160 180 190 200 210 220 230 240 250 260 270 280 290

GAP WIDTH (mm)

WA

TER

PR

ESSU

RE

(Mp

a)

170 150 160 170 180 190 200 220 230 240 250 260 270 280 290 300 310 320 330 340 340

GAP WIDTH (mm)

WA

TER

PR

ESSU

RE

(Mp

a)

210

0.20

0.40

0.60

0.80

1.00

1.20

1.40

0.10

0.20

0.30

0.40

0.50

0.60

0.70

0.80

0.90

0.00

NominalGap Width

NominalGap Width

Min.Gap Width

Min.Gap Width

Min.Gap Width

Min.Gap Width

Max.Gap Width

Min.Gap Width

Min.Gap Width

Max.Gap Width

Max.Gap Width

Max.Gap Width

Max.Gap Width

Max.Gap Width

NominalGap Width

NominalGap Width

Omegatec 1300 : A01

SEAL EXPANSION JOINT Concrete to Concrete | Steel to Steel

50 - 250 mm ( 2 - 10” ) Expansion Gaps

Omegatec 1300 : A01-140 Omegatec 1300 : A01-200 Omegatec 1300 : A01-250

VEXCOLT | United Kingdom | T : +44 (0) 1752 894133 | E : [email protected] | W : www.vexcolt.com