Schematics Update User Bulletin

download Schematics Update User Bulletin

of 26

Transcript of Schematics Update User Bulletin

  • 8/13/2019 Schematics Update User Bulletin

    1/26

    Schematics Update

    Release 12.0.SP6

    User Bulletin

  • 8/13/2019 Schematics Update User Bulletin

    2/26

    Disclaimer

    Information of a technical nature, and particulars of the product and its use, is given by AVEVASolutions Ltd. without warranty. However, it is acknowledged that there may be errors or omissions inthis publication.

    Neither the author nor AVEVA Solutions Ltd. shall be liable to any person or entity for any actions,claims, loss, or damage arising from the use or possession of any information, particulars, or errors inthis publication, or any incorrect use of the product, whatsoever.

    Copyright

    All rights reserved. The information contained in this document is commercially sensitive, and shall notbe copied, reproduced, stored in a retrieval system, or transmitted without the prior written permission ofAVEVA Solutions Ltd. Where such permission is granted, it expressly requires that this Disclaimer andCopyright notice is prominently displayed at the beginning of every copy that is made.

    Neither whole nor part of the product described in this publication may be adapted, reproduced, reverseengineered, or copied in any material or electronic form without the prior written permission of AVEVASolutions Ltd.

    Neither whole nor part of the product described in this publication may be incorporated into any third-party software, product, machine, or system without the prior written permission of AVEVA SolutionsLtd.

    The AVEVA products described in this guide are to be installed and operated strictly in accordance withthe terms and conditions of the respective license agreements, and in accordance with the relevant UserDocumentation. Unauthorised or unlicensed use of the product is strictly prohibited.

    First published 2010.

    AVEVA Solutions Ltd and its subsidiaries.

    AVEVA Solutions Ltd, High Cross, Madingley Road, Cambridge, CB3 0HB, United Kingdom.

    TrademarksAVEVA is the registered trademark of AVEVA Solutions Ltd. Unauthorised use of the AVEVA trademarkis strictly forbidden.

    Microsoft, Windows, and Windows XP are trademarks or registered trademarks of the MicrosoftCorporation, registered in the USA and elsewhere.

    Intel is a trademark or registered trademark of the Intel Corporation, registered in the USA andelsewhere.

    Any other product name or logo is the copyright, trademark, or registered trademark of its respectiveowner.

  • 8/13/2019 Schematics Update User Bulletin

    3/26

    12/10/2010 3

    Contents

    Schematics Update Release 1Release 12.0.SP6 1User Bu l let in 11. In t roduct ion 4

    1.1 About this Software Release 41.2 About this Manual 41.3 Software Distribution & Installation 41.4 AVEVA Schematic Model Products Portfolio 51.5 Operating Environment 5

    1.5.1 PC hardware configuration 51.6 Upgrading from the 12.0.SP6 Release 5

    2. AVEVA Diagrams 72.1 Flow Direction Enhancements 72.2 Area Shapes 82.3 Auto Formatting Rules 92.4 Release Diagram Sheets to 3D and Performance of the SaveWork Command10 2.5 Update of Multiple Diagrams 112.6 Save As with Copy of DB Data 122.7 Session defaults 132.8

    DWG File Export Enhancements 14

    2.9 New Excel Import / Export Function 152.10 Export Consistency Check Result to File 16

    3. Schematic 3D Integrator 173.1 Line List Comparison 173.2 Comparison Colour Key 183.3 Print Compare Report and Export Compare Report to Excel 193.4 New Diagram Viewer 20

    4. Schemat ic Model Manager 214.1 New Excel Import / Export function 214.2 New Diagram Viewer 22

    5. AVEVA Instrum entat ion Data Update Ad d-in 235.1 Filtering Function 235.2 Cable Data Interface 24

    http://sena1_offline/users/lena.strand/Release%20Documentation/Bulletins/12.0.SP6_Bulletin/User%20Bulletin%20Schematics%20Add-on%20Pack%20for%20120sp6_v3.doc%23_Toc274214207http://sena1_offline/users/lena.strand/Release%20Documentation/Bulletins/12.0.SP6_Bulletin/User%20Bulletin%20Schematics%20Add-on%20Pack%20for%20120sp6_v3.doc%23_Toc274214207http://sena1_offline/users/lena.strand/Release%20Documentation/Bulletins/12.0.SP6_Bulletin/User%20Bulletin%20Schematics%20Add-on%20Pack%20for%20120sp6_v3.doc%23_Toc274214208http://sena1_offline/users/lena.strand/Release%20Documentation/Bulletins/12.0.SP6_Bulletin/User%20Bulletin%20Schematics%20Add-on%20Pack%20for%20120sp6_v3.doc%23_Toc274214208http://sena1_offline/users/lena.strand/Release%20Documentation/Bulletins/12.0.SP6_Bulletin/User%20Bulletin%20Schematics%20Add-on%20Pack%20for%20120sp6_v3.doc%23_Toc274214209http://sena1_offline/users/lena.strand/Release%20Documentation/Bulletins/12.0.SP6_Bulletin/User%20Bulletin%20Schematics%20Add-on%20Pack%20for%20120sp6_v3.doc%23_Toc274214209http://sena1_offline/users/lena.strand/Release%20Documentation/Bulletins/12.0.SP6_Bulletin/User%20Bulletin%20Schematics%20Add-on%20Pack%20for%20120sp6_v3.doc%23_Toc274214209http://sena1_offline/users/lena.strand/Release%20Documentation/Bulletins/12.0.SP6_Bulletin/User%20Bulletin%20Schematics%20Add-on%20Pack%20for%20120sp6_v3.doc%23_Toc274214208http://sena1_offline/users/lena.strand/Release%20Documentation/Bulletins/12.0.SP6_Bulletin/User%20Bulletin%20Schematics%20Add-on%20Pack%20for%20120sp6_v3.doc%23_Toc274214207
  • 8/13/2019 Schematics Update User Bulletin

    4/26

    12/10/2010 4

    1. Introduction

    1.1 About this Software ReleaseThe 12.0.SP6 Schematics Update Release is supplied on a DVD-R, which self-installs using

    standard Microsoft installation procedures. The full software suite is usually loaded onto individual

    PCs running Windows, with the license server and file loaded onto a networked Windows server.

    The 12.0.SP6 Schematics Update Release is deployed as fix release no 8 on top of either AVEVA

    PDMS 12.0.SP6.or AVEVA Hull & Outfitting 12.0.SP6. So it is a pre-requisite to first install 12.0.SP6

    before applying the 12.0.SP6 Schematics Update Release. Any error corrections and minor

    improvements delivered as part of previous hotfixes have been rolled up and are included into the

    12.0.SP6 Schematics Update Release. In addition to this the 12.0.SP6 Schematics Update

    Release also includes a number of new features for the Schematics applications, which are

    AVEVA Diagrams, AVEVA Schematic Model Manager and AVEVA Schematic 3D Integrator.

    Please note that 12.0.SP6 onwards requires Flexman 5 and an appropriate licenseit will notwork with Flexman 3 or 4. For further details of Flexman License Server releases, please seehttp://support.aveva.com/support/United_Kingdom/Flexman/Flexman_Software_Profiles.htm.

    1.2 About this Manual

    This manual gives an overview of changes in the Schematic Model Applications since the

    12.0.SP6 Service Pack. It is primarily aimed at users upgrading from that release. Users that

    upgrade from previous releases will have to also refer the User Bulletins for 12.0.SP6 to obtain a

    complete understanding of the full functional scope of this release.

    1.3 Software Distribution & Installation

    Please note that the installation process has been changed for 12.0.SP4 onwards. The installers

    now use standard Microsoft Installer (MSI) technology, which facilitates silent installations through

    standard MSI means. They are usually triggered by use of a setup.exe file.

    http://support.aveva.com/support/United_Kingdom/Flexman/Flexman_Software_Profiles.htmhttp://support.aveva.com/support/United_Kingdom/Flexman/Flexman_Software_Profiles.htmhttp://support.aveva.com/support/United_Kingdom/Flexman/Flexman_Software_Profiles.htm
  • 8/13/2019 Schematics Update User Bulletin

    5/26

    12/10/2010 5

    1.4 AVEVA Schematic Model Products Portfolio

    The AVEVA Schematic Model Product portfolio consists of the following products all based on the

    AVEVA Design Platform and Dabacon database technologies. These are add-on applications to

    12.0.SP6 as follows.

    AVEVA Diagrams Used for creating P&IDs, HVAC and Cable diagrams. It saves both

    the diagram and the engineering objects in the Schematic Model

    database.

    AVEVA Schematic

    Model Manager

    Provides unrivalled features for the consolidation of all P&ID data

    for a project, independently of the P&ID authoring tool.

    AVEVA Schematic 3D

    Integrator

    Provides an integrated Schematic / 3D environment that allows

    customers to build their 3D model in a controlled manner, directly

    from the information on a P&ID, and enables consistency checks

    between the Schematic model and the 3D model.

    1.5 Operating Environment

    1.5.1 PC hardware configuration

    Please refer to the Minimum Systems Requirements Manual.

    1.6 Upgrading from the 12.0.SP6 Release

    The 12.0.SP6 Schematics Update Release is fully compatible with 12.0.SP6 data with the followingexception:

  • 8/13/2019 Schematics Update User Bulletin

    6/26

    12/10/2010 6

    Note!:The following settings files for AVEVA Diagrams will need to be manually upgraded:

    DiagramsAttributePresentation.xml

    DiagramsDefaultSettings.xml

    The files that are included in the 12.0.SP6 delivery may contain additional settings that have been

    added in this release. If these files will be manually overwritten with the previous files holdingapplication settings done by users, the new settings will no longer be visible in e.g. the Diagrams

    Options dialogue.

    Recommended procedure:

    1. Back up the current versions of these files

    2. Install the 12.0.SP6 Schematics Update Release

    3. Merge the files by either copying and inserting new settings from the new files into the old

    ones or by copying and applying user settings from the old files into the new ones. It is

    recommended to use an XML merging tool for this task. One example of an XML merge

    tool is XMLDiffMerge from IBM.

  • 8/13/2019 Schematics Update User Bulletin

    7/26

  • 8/13/2019 Schematics Update User Bulletin

    8/26

    12/10/2010 8

    2.2 Area Shapes

    The new Area Shape function allows the assignment of attribute values to schematic items based

    on their location in the diagram drawing. An area shape can for instance represent a room, a

    package, a spec or any other entity.

    By dropping a schematic item inside the border of the area, the attribute value associated with the

    area shape will be applied to the schematic item. For example, the Location attribute of an

    equipment item can receive a value of 202 when the item is dropped or moved into the area

    representing room 202.

    For More Information

    See also User GuideAVEVA Diagrams / Working with Diagrams / Area Shape.

  • 8/13/2019 Schematics Update User Bulletin

    9/26

  • 8/13/2019 Schematics Update User Bulletin

    10/26

    12/10/2010 10

    2.4 Release Diagram Sheets to 3D and Performance ofthe SaveWork Command

    A new function for releasing diagrams to 3D is now available. This function will allow users to

    selectively create SVG viewer files and set release status for a diagram or sheet at a time.

    Together with this function there is also a new option for Savework behaviour, whereby it is

    possible to specify that SVG files should not be created on SaveWork and only by the Release

    Diagram to 3D function. If this feature is enabled, then the performance of Savework can be

    significantly improved, as the creation of SVG files may take some time to execute.

    For More Information

    See also User GuideAVEVA Diagrams / Working with Diagrams / File Handling / Save Work andSVG Creation.

  • 8/13/2019 Schematics Update User Bulletin

    11/26

  • 8/13/2019 Schematics Update User Bulletin

    12/26

    12/10/2010 12

    2.6 Save As with Copy of DB Data

    In previous releases, the user would manually have to redefine the items on a diagram created by

    the SaveAs function. A new possibility has now been introduced to get a copy of all related

    database items when a diagram is created by the SaveAs function. An options dialogue provides apossibility to affect how some special cases will be handled.

    For More Information

    See also User GuideAVEVA Diagrams / Working with Diagrams / File Handling / Save As with

    Copy of Data.

  • 8/13/2019 Schematics Update User Bulletin

    13/26

    12/10/2010 13

    2.7 Session defaults

    A new Default Attributes feature has been introduced for assigning default values to items created

    during the program session. Values will be set for any items where the chosen attribute is

    applicable.

    Also, the previously available Default Groups and Default System functions have been combined

    together with Session Defaults into a common dialogue. This dialogue is available from the

    Session Defaults panel in the status bar at the bottom right hand corner of the application window.

    For More Information

    See also User GuideAVEVA Diagrams / Getting Started / Making Settings for the Program

    Session / Set Up Default Groups, Default System and Default Attributes.

  • 8/13/2019 Schematics Update User Bulletin

    14/26

    12/10/2010 14

    2.8 DWG File Export Enhancements

    The DWG export function has been enhanced with a possibility to manage layers. Any layers

    created in the Visio drawing will be preserved into the created DWG file. It is also possible to

    configure the usage of ByLayer for colours, line widths and line patterns.

    For More Information

    See also User GuideAVEVA Diagrams / Utilities / DWG Export.

  • 8/13/2019 Schematics Update User Bulletin

    15/26

    12/10/2010 15

    2.9 New Excel Import / Export Function

    A new Excel Import / Export function is available in Diagrams as well as Schematic Model

    Manager. This function can be used for importing data from Excel files into a Schematic Model

    database. It includes a possibility to configure element types and attribute mappings. Suchconfigurations can be named and saved for re-use at a later time. During import there is also

    highlighting of changes with Accept / Reject options for each record or attribute.

    For More Information

    See also User GuideAVEVA Diagrams / Working with Diagrams / Importing and Exporting Data to

    the DB.

  • 8/13/2019 Schematics Update User Bulletin

    16/26

    12/10/2010 16

    2.10 Export Consistency Check Result to File

    A new feature has been added to allow the export of a consistency check result. After having done

    a consistency check for a diagram, the user can right click and choose Export to. In the Save

    As dialog it is possible to choose text file format or Excel file format.

    For More Information

    See also User GuideAVEVA Diagrams / Working with Diagrams / Main Gui Components /

    Message Log and Working with Diagrams / Main Gui Components / Consistency Check.

  • 8/13/2019 Schematics Update User Bulletin

    17/26

    12/10/2010 17

    3. Schematic 3D Integrator

    Here follows a list of new enhancements included in the 12.0.SP6 Schematics Update Release

    release. For more information about these features, please refer to the Schematic 3D IntegratorUser Guide.

    3.1 Line List Comparison

    In addition to the existing capabilities for Schematic P&ID3D comparison, there is now also a

    new possibility for line list comparison. In case the schematic model is loaded with line list data

    rather than the full P&ID-based connectivity model, then this data can now be compared against

    3D model data. This includes comparison of From/To line list attributes against 3D connectivity, as

    well as comparison of other attribute values between lines and 3D pipes.

    For More InformationSee also User GuideSchematic 3D Integrator / Integrator Controls / How to use the Bar

    Menu / Line List Options.

  • 8/13/2019 Schematics Update User Bulletin

    18/26

    12/10/2010 18

    3.2 Comparison Colour Key

    A colour key window for comparison colours is now available. This window shows an explanation

    for the colours used for presenting differences in the 3D and Schematics views.

    For More Information

    See also User GuideSchematic 3D Integrator / Integrator Controls / How to use the Bar

    Menu / Display.

  • 8/13/2019 Schematics Update User Bulletin

    19/26

    12/10/2010 19

    3.3 Print Compare Report and Export Compare Report toExcel

    The integrator compare report can now be printed and exported to Excel. These functions operateson the list view found in the Details tab of the comparison report and allow the main results of

    comparison to be printed or exported to a single Excel worksheet. This worksheet will show a side-

    by-side match of objects and includes comparison status and comparison comment.

    For More Information

    See also User GuideSchematic 3D Integrator / How Integrator Compares Schematic and

    3D Data / Example Compare Report.

  • 8/13/2019 Schematics Update User Bulletin

    20/26

    12/10/2010 20

    3.4 New Diagram Viewer

    The SVG format diagram viewer included in Schematic 3D Integrator and Schematic Model

    Manager has been replaced by a new viewer developed by AVEVA. This means that it is no longer

    required to separately download and install the Adobe SVG viewer. In addition to not beingdependent on the Adobe viewer, the new viewer also provides an improved overlay of compare

    colours and line graphics as well as a generally clearer view of diagram graphics.

    For More Information

    See also User GuideSchematic 3D Integrator / Integrator Controls / How to Use the

    Diagram Viewer.

    Ado be SVG viewer

    AVEVA SVG viewer

  • 8/13/2019 Schematics Update User Bulletin

    21/26

    12/10/2010 21

    4. Schematic Model Manager

    Here follows a list of new enhancements included in the 12.0.SP6 Schematics Update Release

    release. For more information about these features, please refer to the Schematic Model Manager

    User Guide.

    4.1 New Excel Import / Export function

    A new Excel Import / Export function is available in Schematic Model Manager as well as

    Diagrams. This function can be used for importing data from Excel files into a Schematic Model

    database. It includes a possibility to configure element types and attribute mappings. Such

    configurations can be named and saved for re-use at a later time. During import there is also

    highlighting of changes with Accept / Reject options for each record or attribute.

    For More Information

    See also User GuideDesign Common Functionality / Excel Import and Export.

  • 8/13/2019 Schematics Update User Bulletin

    22/26

    12/10/2010 22

    4.2 New Diagram Viewer

    The SVG format diagram viewer included in Schematic Model Manager and Schematic 3D

    Integrator has been replaced by a new viewer developed by AVEVA. This means that it is no

    longer required to separately download and install the Adobe SVG viewer. In addition to not beingdependent on the Adobe viewer, the new viewer also provides a generally clearer view of diagram

    graphics.

    For More Information

    See also User GuideSchematic Model Manager / Previewing Diagrams before Export

    /Schematic Model Manager Diagram Viewer.

    Ado be SVG viewer

    AVEVA SVG viewer

  • 8/13/2019 Schematics Update User Bulletin

    23/26

    12/10/2010 23

    5. AVEVA Instrumentation Data Update Add-in

    Here follows a list of new enhancements included in the 12.0.SP6 Schematics Update Release.

    For more information about these features, please refer to the AVEVA Instrumentation DataUpdate Add-in User Guide.

    5.1 Filtering Function

    A filtering function has been added to the AVEVA Instrumentation Data Update Add-in. This

    provides a way to pre-filter the data coming from AVEVA Instrumentation before displaying it in the

    grid, and allows users to compare a subset of the entire AVEVA Instrumentation project against

    Schematic Model data.

    For More Information

    See also User GuideInstrumentation Data Update / Compare and Update Data / Filter.

  • 8/13/2019 Schematics Update User Bulletin

    24/26

    12/10/2010 24

    5.2 Cable Data Interface

    The Instrumentation Data Update Add-in can now also be used for transferring cable and

    equipment data from AVEVA Instrumentation to the PDMS catalogue and to 3D cable design. In

    addition to Diagrams and Schematic Model Manager, this Add-in can now also be hosted inParagon, in Design and in Outfitting Design, and is capable of accessing Cable and Equipment

    data stored in AVEVA Instrumentation.

    Please note that this functionality requires AVEVA Instrumentation 12.0.SP5 to be installed.

    For More Information

    See also User GuideInstrumentation Data Update / Compare and Update Data / Update

    the Target Database / Update the Design Database.

  • 8/13/2019 Schematics Update User Bulletin

    25/26

    12/10/2010 25

    This page left blank intentionally

  • 8/13/2019 Schematics Update User Bulletin

    26/26

    AVEVA Solutions Ltd., High Cross, Madingley Rd, Cambridge CB3 0HB, UK