SCALE MASTER II V Multi-Scale Digital Plan Measure

44
Multi-Scale Digital Plan Measure SCALE MASTER ® II V2.0 User’s Guide

Transcript of SCALE MASTER II V Multi-Scale Digital Plan Measure

Page 1: SCALE MASTER II V Multi-Scale Digital Plan Measure

Multi-Scale Digital Plan Measure

SCALE MASTER® II V2.0

User’s Guide

UG6130E-C 4/4/03 12:39 PM Page 1

Page 2: SCALE MASTER II V Multi-Scale Digital Plan Measure

Preliminary InformationIntroduction . . . . . . . . . . . . . . . . . . . .3Key Definitions . . . . . . . . . . . . . . . . .4Adjusting the Wheel . . . . . . . . . . . . .8

Using the Scale Master IIImperial/Metric Modes . . . . . . . . . .9“Rolling” a Measurement . . . . . . .10Built-in Scales . . . . . . . . . . . . . . . . . .12Changing Measurement Units . . .13Converting Between Scales . . . . . .14Locking Scale Settings . . . . . . . . . .15Using Memory Function . . . . . . . .15Programming Mode . . . . . . . . . . . .18Setting Custom Scales . . . . . . . . . . .19Using Custom Scale/Ruler . . . . . .22Setting an Auto-Count Value . . . . .23Setting a Constant Value (+K) . . . .25Finding Area and Volume . . . . . . .27Connecting to a PC (optional) . . . .31

AppendixError/Auto-Range Function . . . . .34Interference . . . . . . . . . . . . . . . . . . .34Battery/Automatic Shut-Off . . . . .35Battery Replacement . . . . . . . . . . . .35Turning the Click & Beep On/Off . . .35Full Reset/All Clear . . . . . . . . . . . .35Register Values/Settings . . . . . . . .36Specifications . . . . . . . . . . . . . . . . . .38Repair and Return . . . . . . . . . . . . . .39Limited Warranty . . . . . . . . . . . . . .40

TABLE OF CONTENTS

2 – Scale Master ®I I v2 .0

UG6130E-C 4/4/03 12:39 PM Page 2

Page 3: SCALE MASTER II V Multi-Scale Digital Plan Measure

Introduction

The Scale MasterII Multi-Scale DigitalPlan Measure has been specificallydesigned to simplify take-offs fromarchitectural and engineering drawings.

◆ Finds linear measurements ofany shape

◆ Finds rectangular areas andvolumes

◆ Converts between scales anddimensions

◆ Built-in push button counter

◆ Auto-Count function

◆ Constant (+K) function

◆ Subtract function

◆ Eight Custom Scales that let youdefine and roll in any scale

PRELIMINARY INFORMATION

3 – User’s Guide

UG6130E-C 4/4/03 12:39 PM Page 3

Page 4: SCALE MASTER II V Multi-Scale Digital Plan Measure

Key Definitions

[Off/On] – Power On/Off switchTurn power On or Off. Turningpower Off clears the display and allvalues previously stored in Mem-ory. Turning the unit Off does notclear scales or modes.

[Lock] – Lock switch Locks the mode and scale so that theycannot inadvertently be changed. It isadvised to operate in the lockedposition unless you are specificallysetting or changing scales.

[Set] – Set key Used to enter a value or to place theunit into a programming mode. Ifalready in a programming mode,[Set] will store the displayed valueand exit the programming mode.

[Sub] – Subtract key Used to toggle the measuring modebetween positive and negative di-rection. While in the negative direc-tion, rolling the unit will subtract therolled distance from any previouslyrolled distances or from zero. When

4 – Scale Master ®I I v2 .0

UG6130E-C 4/4/03 12:39 PM Page 4

Page 5: SCALE MASTER II V Multi-Scale Digital Plan Measure

[Sub] is pressed simultaneously with[Count], [+K] or [M+], the unit willsubtract the appropriate value.

[Count] – Count keyUsed to increase the Count value byone. Count is active in all modes.Pressing [Reset] and [Count] simulta-neously will clear the count.

[+K] – Constant key Used to add a pre-set “constant”value to the displayed measuredvalue. To set a constant value, youpress [Set] [+K] to place the unit inprogramming mode.

[Rcl] – Recall key Used to recall stored values. Whenyou press [Rcl] [Rcl], the last valuerolled is displayed.

[Mode] – Mode key Used to cycle through the followingscale modes (in sequence):

1) Architectural (ARCH); 2) Engineering 1 (ENG 1)3) Engineering 2 (ENG 2);4) Map (MAP); 5) Custom (CUSTOM).

5 – User’s Guide

UG6130E-C 4/4/03 12:39 PM Page 5

Page 6: SCALE MASTER II V Multi-Scale Digital Plan Measure

When in programming mode, thiskey moves the cursor back to theprevious item programmed.

[Scale] – Scale key Used to cycle through the variousscales within each scale mode.When in the programming mode,this key moves the cursor forwardto the next item to be programmed.

[M+] – Memory key Used to add and store a displayedvalue into Memory. When pressed,the value is added to memory, thedisplay is cleared to “0,” and the in-dicator “M” lights. When in pro-gramming mode, this key advancesthe flashing digit or units by one.

[Length] – Length key Used to store a value in the Lengthregister or recall the current valuestored in the Length register.

[Width] – Width key Used to store a value in the Widthregister, or recall the current valuestored in the Width register.

6 – Scale Master ®I I v2 .0

UG6130E-C 4/4/03 12:39 PM Page 6

Page 7: SCALE MASTER II V Multi-Scale Digital Plan Measure

[Sq/Cu] – Area/Volume key Used to set or view height andcalculate area and volume:

1) The first press of this key calcu-lates and displays the area us-ing values stored in the Lengthand Width registers.

2) The second press calculates anddisplays the volume usingLength, Width and Height.

3) The third press displays the valuestored as Height.

When you press [Set] [Sq/Cu], youcan set a fixed height. While youare in the programming mode,pressing [Set] will store the value asheight and return the unit to nor-mal operation.

[Reset]Used to reset the display. Whenpressed simultaneously with anotherkey, it clears the value of that key(i.e., [Reset] [Length] clears the valuestored in the Length register).

7 – User’s Guide

UG6130E-C 4/4/03 12:39 PM Page 7

Page 8: SCALE MASTER II V Multi-Scale Digital Plan Measure

Adjusting the Wheel

The Celcon® polymer wheel can be ad-justed for each user’s preference. Toadjust the wheel, take a small, flat-headjeweler’s screwdriver and slightly ro-tate the screw located near the wheeltip. Rotating the screw about 1/4 to1/3 turn should be sufficient. Rotatingthe screw within those two valuesshould adjust the wheel between freespinning (which is too loose) to skid-ding (which is too tight).

Rotate to Adjust Wheel

8 – Scale Master ®I I v2 .0

UG6130E-C 4/4/03 12:39 PM Page 8

Page 9: SCALE MASTER II V Multi-Scale Digital Plan Measure

Imperial/Metric Modes

The Scale Master II is set up to useImperial (English) dimensionalunits by default. The Scale Master IIcan be set up to use Metric scalesby using the following sequence:

1) Turn unit off via switch.

2) Press and hold [SUB] key.

3) Turn unit on via switch.

4) Release [SUB] key.

While in Metric mode, MET will re-main lit in the scale box.

Repeat the procedure above toswitch back to Imperial mode.

USING THE SCALE MASTER II

9 – User’s Guide

UG6130E-C 4/4/03 12:39 PM Page 9

Page 10: SCALE MASTER II V Multi-Scale Digital Plan Measure

“Rolling” a Measurement

To take a measurement with the ScaleMaster II:

1) Switch the unit on. If the displaydoes not show zero (0), press the[Reset] key to clear the display.

2) Select your type of scale by press-ing the [Mode] key. Then press the[Scale] key to select your scale.

3) Begin rolling. The display will reg-ister your measurements. Whenyou roll the unit, be sure to hold theunit upright (see picture 1 - nextpage).

Also make sure you start and stopat the exact points you are measur-ing. Otherwise your roll may notbe accurate (see picture 2).

4) To store your measurement, pressthe appropriate key (ex. [Length] tolabel as length, [Width] to label aswidth, etc).

5) Press [Reset] to reset the unit andbegin a new measurement.

10 – Scale Master ®I I v2 .0

UG6130E-C 4/4/03 12:39 PM Page 10

Page 11: SCALE MASTER II V Multi-Scale Digital Plan Measure

11 – User’s Guide

UG6130E-C 4/4/03 12:39 PM Page 11

Page 12: SCALE MASTER II V Multi-Scale Digital Plan Measure

Built-In Scales

Imperial (English) Units

Architect Engineer-I Engineer-II MapARCH ENGI ENGII MAP1 foot= 1 inch= 1 inch= 1 inch=

1/32” 10.0’ 300.0’ 1.0 Mile1/16” 20.0’ 333.3’ 1.5 Mi3/32” 30.0’ 400.0’ 2.0 Mi1/8” 40.0’ 416.6’ 3.0 Mi3/16” 50.0’ 500.0’ 4.0 Mi1/4” 60.0’ 583.3’ 5.0 Mi3/8” 83.3’ 600.0’ 6.0 Mi1/2” 100.0’ 625.0’ 10.0 Mi3/4” 166.6’ 666.6’ 20.0 Mi1/1 (1”) 200.0’ 750.0’ 24.0 Mi3/2 (11/2”) 250.0’ 1,000.0’ 25.0 Mi2/1 (2”) 1,200.0’3/1 (3”) 2,000.0’4/1 (4”) 3,000.0’

12 – Scale Master ®I I v2 .0

UG6130E-C 4/4/03 12:39 PM Page 12

Page 13: SCALE MASTER II V Multi-Scale Digital Plan Measure

Metric Units

Architect Engineer-I Engineer-II MapARCH ENGI ENGII MAP

1:1 1:100.0 1:1,000 1:100k1:2 1:125.0 1:1,250 1:125k1:3 1:150.0 1:1,500 1:200k1:4 1:200.0 1:1,625 1:250k1:5 1:250.0 1:2,000 1:500k1:10 1:300.0 1:2,500 1:1,000k1:20 1:400.0 1:5,000 1:2,000k1:25 1:500.0 1:6,000 1:2,500k1:30 1:10k1:40 1:12.5k1:50 1:20k1:75 1:25k

1:50k

Note: See “Imperial/Metric Modes” for in-structions on how to change fromImperial and Metric settings.

Changing Measurement Units

A) Press [Sub] and [Scale] simultane-ously to toggle between Feet-Inchand Decimal Feet format (Imperial[English] Mode only).

13 – User’s Guide

UG6130E-C 4/4/03 12:39 PM Page 13

Page 14: SCALE MASTER II V Multi-Scale Digital Plan Measure

You can also convert values fromImperial Units (English) to MetricUnits within the Imperial mode.

B) Press [Set] [Mode] and continuepressing [Mode] to cycle throughavailable units of measurement.

Converting Between Scales

The Scale Master II can automaticallyconvert values between scales. For ex-ample, 20 feet rolled in 1/16” scale willbe converted to 10 feet in 1/8” scale.You may want to roll a value in onescale and then add that exact value(unconverted) in another scale.

1) Roll a value and press the Memorykey [M+]. Change scales.

2) Roll another value and press [M+].

3) Press [Rcl] [M+] to recall the com-bined total.

14 – Scale Master ®I I v2 .0

UG6130E-C 4/4/03 12:39 PM Page 14

Page 15: SCALE MASTER II V Multi-Scale Digital Plan Measure

Locking Scale Settings

Your Scale Master II comes equipped witha lock switch that prevents inadvertentlychanging drawing scales. When the lockis activated, a lock symbol will bedisplayed in the LCD. While active, theScale and Mode cannot be revised (otherthan removal of the battery).

Using the Memory Function

The Memory function allows you toadd rolled or counted values. But youcannot add dimensioned (rolled) andnon-dimensioned (counted) values.

To add rolled values:

1) Roll the first value*. Press [M+].The display resets to “0,” the Mem-ory indicator “M” lights and thevalue is added to Memory.

2) Roll the next value. Press [M+]. Thisvalue is added to your previousvalue stored in Memory.

15 – User’s Guide

UG6130E-C 4/4/03 12:39 PM Page 15

Page 16: SCALE MASTER II V Multi-Scale Digital Plan Measure

3) You can continue to add values us-ing the [M+] key. Press [Rcl] [M+] toreview the total in Memory.

*Note: For Count values, you must pressthe [Count] key to count your val-ue. Then press [Rcl] [Count] tomove the count value to the maindisplay. Press [M+] to add this val-ue to Memory.

The annunciator “M” will displaywhen a value is stored in Memory.

16 – Scale Master ®I I v2 .0

UG6130E-C 4/4/03 12:39 PM Page 16

Page 17: SCALE MASTER II V Multi-Scale Digital Plan Measure

Other Memory Function Keystrokes

[Set] [M+]Replaces the contents of Memorywith the displayed value.

[Set] then [Sub] and [M+] simultaneously

Replaces the contents of Memorywith the negative of the value inthe main display.

[Sub] and [M+] simultaneouslySubtracts the value in the maindisplay from the value stored inMemory.

[Reset] and [M+] simultaneouslyClears the Memory register.

17 – User’s Guide

UG6130E-C 4/4/03 12:39 PM Page 17

Page 18: SCALE MASTER II V Multi-Scale Digital Plan Measure

Programming Mode

The Scale Master II allows you to pre-set values into frequently used keys,including:

◆ Custom Scales (4 Imp/4 Met)

◆ Auto-Count distance

◆ +K (Constant) value

◆ Height value

To begin setting values, press the [Set]key and then the desired key to be pro-grammed. The following keys are usedin programming mode:

[Scale] advances the cursor to thenext item.

[Mode] moves the cursor back to theprevious item.

[M+] changes the value within anitem.

[Reset] exits the programming modewithout saving any values.

[Set] exits and saves changes.

18 – Scale Master ®I I v2 .0

UG6130E-C 4/4/03 12:39 PM Page 18

Page 19: SCALE MASTER II V Multi-Scale Digital Plan Measure

Setting Custom Scales

You can program and store eight Cus-tom Scales: four in Imperial (English)and four in Metric Units. The defaultunits of measurement for Imperial areFeet-Inches “FT-IN” and for Metric, Mil-limeters “MM.” If all custom scale set-tings are filled, the unit will start overfrom one.

You can set a custom scale two ways:by “rolling in” a known distance or bysetting the exact distance.

“Rolling” a Custom Scale

1) Press [Mode] until 1:CUS_x (x beinga number 1-4) appears in the scalebox display.

2) Press [Set] [Scale]. “ROLL” will ap-pear in the main display.

3) Roll desired dimension. “ROLLING“now appears in the main display.

19 – User’s Guide

UG6130E-C 4/4/03 12:39 PM Page 19

Page 20: SCALE MASTER II V Multi-Scale Digital Plan Measure

4) Press [Scale]. The appropriate an-nunciator will begin flashing “FT-IN“ for Imperial Mode, “MM” forMetric Mode.

5) If you want to change the units ofmeasurement, press [M+]. You canrepeatedly press this key until youreach the desired unit of measure-ment. Then press the [Scale] key tobegin setting the distance.

6) Press [M+] to increment the dis-tance. When you have reached thecorrect number, press [Scale] to ad-vance to the next digit. You canpress the [Mode] key to move backone digit.

7) Once the desired value has beenset, press [Set] to store value and ex-it the programming mode.

Note: Pressing [Reset] will exit the pro-gramming mode without saving anyvalue as the Custom Scale.

20 – Scale Master ®I I v2 .0

UG6130E-C 4/4/03 12:39 PM Page 20

Page 21: SCALE MASTER II V Multi-Scale Digital Plan Measure

Setting a Custom Scale

1) Press [Mode] until 1:CUS_x (x beinga number 1-4) appears in the scalebox display.

2) Press [Set] [Scale]. “ROLL” will ap-pear in the main display.

3) Press [Scale] again to begin enter-ing the custom scale. The appro-priate annunciator will beginflashing “FT-IN” for Imperial Mode,“MM” for Metric Mode.

5) If you want to change the units ofmeasurement, press [M+]. You canrepeatedly press this key until youreach the desired unit of measure-ment. Then press the [Scale] key tobegin setting the distance.

6) In Imperial mode, the scale will beone inch to whatever you set. InMetric mode, it will be one mil-limeter to whatever you set. Press[M+] to increment the distance.When you have reached the correctnumber, press [Scale] to advance to

21 – User’s Guide

UG6130E-C 4/4/03 12:39 PM Page 21

Page 22: SCALE MASTER II V Multi-Scale Digital Plan Measure

the next digit. You can press the[Mode] key to move back one digit.

7) Once the desired value has beenset, press [Set] to store the valueand exit the programming mode.

Press [Rcl] [Scale] to verify the currentCustom Scale.

Using the Custom Scale/Ruler

The default value (after a full reset) forany Custom Scale is one-to-one (onefoot equals one foot). This lets you useyour Scale Master II as a rolling ruler (inFeet-Inches), which is especially usefulfor measuring irregular shapes.

1) To reset your Custom Scale settingto a one-to-one ratio, press [Reset]and [Sub] simultaneously.

2) Then press the [Mode] key until the“Custom” mode appears.

Begin rolling. To roll in decimal feet in-stead of feet-inches (Imperial only),press [Sub] and [Scale] simultaneously.

22 – Scale Master ®I I v2 .0

UG6130E-C 4/4/03 12:39 PM Page 22

Page 23: SCALE MASTER II V Multi-Scale Digital Plan Measure

Setting an Auto-Count Value

The Scale Master II has an Auto-Countmode that allows you to count howmany times you’ve rolled a certain dis-tance. You will hear a beep each timeyou roll that distance.

To program in Auto-Count mode:

1) Press [Set] [Count] to enter Auto-Count programming mode. Theappropriate annunciator will beginflashing “FT-IN” for Imperial Mode,“MM” for Metric Mode. The Auto-Count annunciator “AUTO”will ap-pear in the scale box display.

2) If you want to change the units ofmeasurement, press [M+]. Repeat-edly press this key until you reachthe desired unit of measurement.Then press the [Scale] key to beginsetting the distance.

3) Press [M+] to increment the dis-tance. When you have reached thecorrect number, press [Scale] to ad-vance to the next digit.

23 – User’s Guide

UG6130E-C 4/4/03 12:39 PM Page 23

Page 24: SCALE MASTER II V Multi-Scale Digital Plan Measure

4) Press [Set] to save changes and putthe unit into Auto-Count measur-ing mode.

5) Roll a distance. The unit will beepeach time you roll the programmeddistance. The count number in thescale box will increment.*

6) Press [Set] [Count] or [Set] [Reset][Count] to exit Auto-Count mode.

*Note: The count number will incrementuntil it reaches 999; after that, anasterisk (*) will appear in the scalebox display and the unit will con-tinue counting from one. To displaythe total accumulated count num-ber on the main display, press [Rcl][Count]. Press [Count] again (i.e.,[Rcl] [Count] [Count]) to recall theset Auto-Count value.

24 – Scale Master ®I I v2 .0

UG6130E-C 4/4/03 12:39 PM Page 24

Page 25: SCALE MASTER II V Multi-Scale Digital Plan Measure

Setting a Constant Value (+K)

This key is used to add a pre-pro-grammed value to the displayed mea-sured value.

If the value is not “live,” then pressingthis key will first reset the display, thenadd the constant value. When a con-stant value is added, the value in thedisplay remains a “live” value.

To set a constant:

1) Press [Set] [+K]. The appropriateannunciator will begin flashing “FT-IN” for Imperial Mode, “MM” forMetric Mode. The constant annun-ciator (a small k) will appear in thescale box display.

2) To change the units of measure-ment, press [M+]. You can repeat-edly press this key until you reachthe desired unit of measurement.Press [Scale] to begin setting thedistance. The first zero will startflashing.

25 – User’s Guide

UG6130E-C 4/4/03 12:39 PM Page 25

Page 26: SCALE MASTER II V Multi-Scale Digital Plan Measure

3) Press [M+] to increment the dis-tance. When you have reached thecorrect number, press [Scale] to ad-vance to the next digit. Press[Mode] to move back one digit.

4) Once the desired value has beenset, press [Set] to save this valueand exit the programming mode.

Other Constant Function Keystrokes

[Rcl] [+K]Allows you to verify the currentconstant value.

[Sub] and [+K] simultaneouslySubtracts the constant value fromthe displayed value.

[Reset] and [+K] simultaneouslyResets the constant value to zero.

26 – Scale Master ®I I v2 .0

UG6130E-C 4/4/03 12:39 PM Page 26

Page 27: SCALE MASTER II V Multi-Scale Digital Plan Measure

Finding Area and Volume

The Scale Master II can calculate areaand volume once you have your valuesset for length, width, and (for volumecalculation only) height. The length,width and height register values arestored in semi-permanent memory.These values will not be cleared whenyou press [Reset] by itself. These valueswill only clear if you:

1) turn off the unit (clears length andwidth only)

2) press [Reset] then the register (clears one value at a time)

3) press [Sub] and [Reset] simultaneously (clears all values)

Once you have rolled or set yourheight value, it will be used for all sub-sequent volume calculations unlessyou change it.

Finding Area

1) Roll the first dimension and press[Length]. This value is stored as thelength and the main display willreset to zero (0).

27 – User’s Guide

UG6130E-C 4/4/03 12:39 PM Page 27

Page 28: SCALE MASTER II V Multi-Scale Digital Plan Measure

2) Roll the second dimension andpress [Width]. This value is storedas the width and the main displaywill reset to zero.

3) Press [Sq/Cu] to calculate the area.

Finding Volume

1) Roll the first dimension and press[Length].

2) Roll the second dimension andpress [Width].

3) Storing a height value (if you havepreviously set a height, skip to step 4):a. To Roll and Store a Height:

i. Roll the third dimension andpress [Set] [SQ/CU]. The displaywill show the rolled value andthe unit of measure will beginflashing.

ii. If you do not want to changethe unit of measure, go tostep iii. To change the unit ofmeasure, press [M+] until youreach the desired unit.

iii. Press [Set] to set the value asheight and the display willclear to zero.

28 – Scale Master ®I I v2 .0

UG6130E-C 4/4/03 12:39 PM Page 28

Page 29: SCALE MASTER II V Multi-Scale Digital Plan Measure

b. To Enter and Store a Height:i. If you are entering a height

(instead of rolling), press [Set][SQ/CU].

ii. If you do not want to changethe unit of measure, go tostep iii. To change the unit ofmeasure, press [M+] until youreach the desired unit.

iii. Press [Scale] to begin settingthe digits. The left-most digitwill begin flashing.Press:[M+] to increment this digit[Sub] to decrement the digit[Scale] to advance to next digit[Mode] to move back one digit

iv. Once you are finished settingthe digits, press [Set] anytimeto store the value as height.The display will clear to zero.

Note: Once you set your height, you do notneed to enter it again unless you want tochange it.

4) To find volume, press [Sq/Cu]. Thefirst press calculates the area; pressthe [Sq/Cu] key again to find vol-ume. Press a third time to displaythe value stored as Height.

29 – User’s Guide

UG6130E-C 4/4/03 12:39 PM Page 29

Page 30: SCALE MASTER II V Multi-Scale Digital Plan Measure

Other Area/Volume Function Keystrokes

[Rcl] [Length]Displays the value stored in theLength register.

[Rcl] [Width] Displays the value stored in theWidth register.

[Reset] and [Length] simultaneouslyClears the value stored as Length.

[Reset] and [Width] simultaneouslyClears the value stored as Width.

[Set]then [Reset] and [Sq/Cu] simultaneously

Clears the value stored as Height.

30 – Scale Master ®I I v2 .0

UG6130E-C 4/4/03 12:39 PM Page 30

Page 31: SCALE MASTER II V Multi-Scale Digital Plan Measure

Connecting to a PC (optional)

The Scale Master II has a built-in com-puter interface connection so that youcan use it with estimating and spread-sheet software programs. Like yourkeyboard, it sends a single value fromthe main display to the selected cell inyour program.

Only the value currently on the maindisplay will be sent to the PC. You mustsend a value in order for the PC to re-ceive it. If you want to send a value,you would first roll or recall the value,then you would press [Set] to send thevalue to the PC.

If you want to temporarily override thesend function, press [Rcl] [Set]. To can-cel the override function, press the [Set]key again.

Note: For more detailed information, seethe instructions included with theinterface kit.

31 – User’s Guide

UG6130E-C 4/4/03 12:39 PM Page 31

Page 32: SCALE MASTER II V Multi-Scale Digital Plan Measure

Basic Functions PC

You can send a value using the [Set]key, then store it as Length, Width,Height, or in the memory, as you nor-mally would. Remember, for Height,press [Rcl] before pressing [Set] [Sq/Cu][Set].

[Rcl] [Set] [Sq/Cu]Stores the rolled value as height.

[Set] then [Reset] and [Sq/Cu] simultaneouslyClears the stored height value.

Memory Functions PC

[Reset] and [M+] simultaneously, then [M+]by itself

Replaces the value previouslystored in Memory with the dis-played value.

[Reset] and [M+] simultaneously, then [Sub]and [M+] simultaneously

Replaces the value previouslystored in Memory with the nega-tive of the displayed value.

32 – Scale Master ®I I v2 .0

UG6130E-C 4/4/03 12:39 PM Page 32

Page 33: SCALE MASTER II V Multi-Scale Digital Plan Measure

Auto-Count Function PC

[Rcl] [Set] [Count]Enters Auto-Count programmingmode. The next press of [Set] exitsAuto-Count mode.

[Reset] and [Count] simultaneouslyClears the Count value.

[Rcl] [Set] then [Reset] and [Count] simul-taneously

Exits the Auto-Count mode.

Set Function PC

[Rcl] [Set]Used to access the Set function forentering programming mode andaccessing special functions with-out sending a value to the PC.

[Rcl] [Set] [Reset]Exits the Set function.

Scale Function PC

[Rcl] [Set] [Scale]In Custom Scale Mode – puts youinto programming mode.

Not in Custom Scale Mode – clearsthe Set function.

33 – User’s Guide

UG6130E-C 4/4/03 12:39 PM Page 33

Page 34: SCALE MASTER II V Multi-Scale Digital Plan Measure

Error/Auto-Range FunctionError Message – If you make an incor-rect entry (such as trying to add di-mensioned and non-dimensionedvalues), the Scale Master II will displaythe word “ERROR.” Press [Reset] to clear.

Auto Range Function – If value is toolarge to display in the selected units ofmeasurement, the answer will be dis-played in the next larger measurementunits instead of showing an error (for ex-ample: “10,000,000 MM” cannot be dis-played, so “10,000 M” will bedisplayed instead).

InterferenceExposure to direct light or close prox-imity to cell phones and other elec-tronic devices may cause interferencewith the Scale Master device and resultin erroneous measurements.

APPENDIX

34 – Scale Master ®I I v2 .0

UG6130E-C 4/4/03 12:39 PM Page 34

Page 35: SCALE MASTER II V Multi-Scale Digital Plan Measure

Battery/Automatic Shut-OffThe Scale Master II is powered by two3-Volt CR-2430 Lithium batteries (6volts total). To conserve battery power,the unit will shut itself off if it is notused for 5 minutes. Press any key to re-store power. All registers and settingsremain intact, including all temporaryregisters.

Battery ReplacementWhen replacing thebatteries, carefullyinsert batteries underthe metal clip. This isthe positive batteryterminal. Do not bend or force downward.

Turning the Click & Beep On/OffThe Scale Master II has a built-in wheelclick and count beep to let you knowwhen rolling or counting. To toggle theclick/beep off or on, press [Sub] and[Mode] simultaneously.

Full Reset/All ClearTo perform a complete reset of the unitand return all registers to their initialdefault values, press [Reset] and [Sub]simultaneously.

35 – User’s Guide

– Negative

+ Positive

UG6130E-C 4/4/03 12:39 PM Page 35

Page 36: SCALE MASTER II V Multi-Scale Digital Plan Measure

Register Values/Settings

Permanent Values/Settings

The following registers/settings will remain in permanent storage, onlychanging:

1) when the settings are revised;2) when the unit is reset

(“All Clear”); or3) when the batteries are changed:

Register Default DefaultSetting Imperial Metric

Mode ARCH ARCHBell Toggle ON ONScale 1/32” 1:1Height 0,000-00 00,000.00Linear FT-IN MMArea SQ FT SQ MMVolume CU FT CU MMHeight FT-IN MMCustom Scales 1:CUSxFT-IN 1:CUS x MM

36 – Scale Master ®I I v2 .0

UG6130E-C 4/4/03 12:39 PM Page 36

Page 37: SCALE MASTER II V Multi-Scale Digital Plan Measure

Semi-Permanent Values/Settings

The following registers/settings arecleared when the Scale Master II is powered down:

Register Default DefaultSetting Imperial Metric

Length 0-0 0.00Width 0-0 0.00Count 0. 0.Subtract Mode OFF OFF

37 – User’s Guide

UG6130E-C 4/4/03 12:39 PM Page 37

Page 38: SCALE MASTER II V Multi-Scale Digital Plan Measure

Specifications

Power Source:Two 3-Volt CR-2430 lithium batteries.Approximately 400 hours normal use.

Display Method:LCD with zero suppression, commas andannunciators.

Display Capacity (Main Display):9,999,999 (7 digits)

Resolution/Accuracy:

.025 Inch/99.75%

Dimensions:7.2” x 1.6” x 0.6” 182mm x 41mm x 15mm

38 – Scale Master ®I I v2 .0

UG6130E-C 4/4/03 12:39 PM Page 38

Page 39: SCALE MASTER II V Multi-Scale Digital Plan Measure

REPAIR AND RETURN

Warranty, Repair and ReturnInformationReturn Guidelines:

1. Please read the Warranty in thisUser's Guide to determine if yourCalculated Industries Scale Master®

remains under warranty beforecalling or returning any device forevaluation or repairs.

2. If your Scale Master won't turn on,check the batteries as outlined in theUser's Guide.

3. If there is a black spot on the LCDscreen, THIS IS NOT A WARRAN-TY DEFECT. The unit can berepaired. Call for a repair quotebefore returning your unit.

4. If you need more assistance, pleasego to our website at www.calculat-ed.com and click on Support, thenRepair Services FAQs.

5. If you believe you need to returnyour calculator, please speak to aCalculated Industries representativefor additional information!

Call Toll Free: 1-800-854-8075

39 – User’s Guide

UG6130E-C 4/4/03 12:39 PM Page 39

Page 40: SCALE MASTER II V Multi-Scale Digital Plan Measure

LIMITED WARRANTY

Calculated Industries, Inc. (“CII”) warrants thisproduct against defects in materials and workman-ship for a period of one (1) year from the date oforiginal consumer purchase in the U.S. If a defectexists during the warranty period, CII at its optionwill either repair (using new or remanufacturedparts) or replace (with a new or remanufacturedunit) the product at no charge.

THE WARRANTY WILL NOT APPLY TO THE PRODUCT

IF IT HAS BEEN DAMAGED BY MISUSE, ABUSE, ALTER-ATION, ACCIDENT, IMPROPER HANDLING OR OPERATION,OR IF UNAUTHORIZED REPAIRS ARE ATTEMPTED OR

MADE. SOME EXAMPLES OF DAMAGES NOT COVERED BY

WARRANTY INCLUDE, BUT ARE NOT LIMITED TO, BAT-TERY LEAKAGE, BENDING, OR VISIBLE CRACKING OF THE

LCD WHICH ARE PRESUMED TO BE DAMAGES RESULT-ING FROM MISUSE OR ABUSE.

To obtain warranty service in the U.S., ship theproduct postage paid to the CII Authorized ServiceProvider listed on the back page of the User’sGuide. Please provide an explanation of the servicerequirement, your name, address, day phone num-ber and dated proof of purchase (typically a salesreceipt). If the product is over 90 days old, includepayment of $6.95 for return shipping and handlingwithin the contiguous 48 states. (Outside the con-tiguous 48 states, please call CII for return shippingcosts.)

A repaired or replacement product assumes theremaining warranty of the original product or 90days, whichever is longer.

Non-warranty Repair Service — USA

Non-warranty repair covers service beyond thewarranty period or service requested due to damageresulting from misuse or abuse.

Contact the CII Authorized Service Provider list-ed on the back page of the User’s Guide to obtaincurrent product repair information and charges. Re-pairs are guaranteed for 90 days.

40 – Scale Master ®I I v2 .0

UG6130E-C 4/4/03 12:39 PM Page 40

Page 41: SCALE MASTER II V Multi-Scale Digital Plan Measure

Repair Service — Outside the USA

Not all countries have CII Authorized ServiceProviders or the same warranty and service policies.To obtain warranty or non-warranty repair servicefor goods purchased outside the U.S., contact thedealer through which you initially purchased theproduct.

If you cannot reasonably have the product re-paired in your area, you may contact CII to obtaincurrent product repair information and charges, in-cluding freight and duties.

Disclaimer

CII MAKES NO WARRANTY OR REPRESENTATION, EI-THER EXPRESS OR IMPLIED, WITH RESPECT TO THE PROD-UCT’S QUALITY, PERFORMANCE, MERCHANTABILITY, OR

FITNESS FOR A PARTICULAR PURPOSE. AS A RESULT, THIS

PRODUCT, INCLUDING BUT NOT LIMITED TO, KEYSTROKE

PROCEDURES, MATHEMAT-ICAL ACCURACY AND PRE-PROGRAMMED MATERIAL, IS SOLD “AS IS,” AND YOU

THE PURCHASER ASSUME THE ENTIRE RISK AS TO ITS

QUALITY AND PERFORMANCE.IN NO EVENT WILL CII BE LIABLE FOR DIRECT, INDI-

RECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAM-AGES RESULTING FROM ANY DEFECT IN THE PRODUCT OR

ITS DOCUMENTATION.The warranty, disclaimer, and remedies set forth

above are exclusive and replace all others, oral orwritten, expressed or implied. No CII dealer, agent,or employee is authorized to make any modifica-tion, extension, or addition to this warranty.

Some states do not allow the exclusion or limita-tion of implied warranties or liability for incidentalor consequential damages, so the above limitationor exclusion may not apply to you. This warrantygives you specific rights, and you may also haveother rights which vary from state to state.

41 – User’s Guide

UG6130E-C 4/4/03 12:39 PM Page 41

Page 42: SCALE MASTER II V Multi-Scale Digital Plan Measure

FCC Class B

This equipment has been certified to comply withthe limits for a Class B computing device, pursuant toSubpart J of Part 15 of FCC rules.

Legal Notices

Software copyrighted and licensed to CalculatedIndustries by Scale Master Technologies, LLC, 2003. User’s Guide copyrighted by CalculatedIndustries, 2003. Scale Master® and Calculated Industries® areregistered trademarks of Calculated Industries, Inc.

ALL RIGHTS RESERVED.

42 – Scale Master ®I I v2 .0

UG6130E-C 4/4/03 12:39 PM Page 42

Page 43: SCALE MASTER II V Multi-Scale Digital Plan Measure

How To Reach Calculated Industries

43 – User’s Guide

MailCalculated Industries, Inc.4840 Hytech DriveCarson City, NV 89706 U.S.A.

Phone1-775-885–4900

Fax1-775-885–4949

[email protected]

World Wide Webhttp://www.calculated.com