SAVIOUR - 4.imimg.com4.imimg.com/data4/UQ/QT/MY-8496973/cl_bharti-enterprise.pdf · The protection...
Transcript of SAVIOUR - 4.imimg.com4.imimg.com/data4/UQ/QT/MY-8496973/cl_bharti-enterprise.pdf · The protection...
![Page 1: SAVIOUR - 4.imimg.com4.imimg.com/data4/UQ/QT/MY-8496973/cl_bharti-enterprise.pdf · The protection area of Rp of ESE LA is calculated according to French standard NFC 17-102, thus](https://reader033.fdocuments.us/reader033/viewer/2022060709/60758a774d68963e9159a8fe/html5/thumbnails/1.jpg)
G E L E A R T H I N G E L E C T R O D E
SAVIOUR OF YOUR VALUABLE
SAVIOUR OF YOUR VALUABLE
AN ISO 9001-2008 & CRISIL RATED COMPANY
![Page 2: SAVIOUR - 4.imimg.com4.imimg.com/data4/UQ/QT/MY-8496973/cl_bharti-enterprise.pdf · The protection area of Rp of ESE LA is calculated according to French standard NFC 17-102, thus](https://reader033.fdocuments.us/reader033/viewer/2022060709/60758a774d68963e9159a8fe/html5/thumbnails/2.jpg)
www.vashudhaearthing.com
THE COMPANY Today, world seems to be smaller place. Almost everybody in using smart gadgets like mobile, laptops.television, industrial equipment and electronic appliances for comfort and effcient productivity.
We have accepted that nobody can live without electricity and if it is, so what are the measurements
for keeping them safe from electricity uctuations? After many years of relentless R&D process, in the
year 2006, we came up with the throbbing idea of making industrial earthing products with the name
of Shri Vasudha Gel Earthing electrode.
Earthing is the first essential and mandatory part of electrical maintenance, Shri Vasudha Gel Earthing
is maintenance free yet it ensures the safety of human life, appliances and machineries with great
ease.
![Page 3: SAVIOUR - 4.imimg.com4.imimg.com/data4/UQ/QT/MY-8496973/cl_bharti-enterprise.pdf · The protection area of Rp of ESE LA is calculated according to French standard NFC 17-102, thus](https://reader033.fdocuments.us/reader033/viewer/2022060709/60758a774d68963e9159a8fe/html5/thumbnails/3.jpg)
G E L E A R T H I N G E L E C T R O D E
VISION
“
“
To make a product that saves and serves
the entire human kind with ease.
A Product to reckon with great built quality.
MISSION
We are on a mission of safety awareness, a mission to make life better and safer“
“
![Page 4: SAVIOUR - 4.imimg.com4.imimg.com/data4/UQ/QT/MY-8496973/cl_bharti-enterprise.pdf · The protection area of Rp of ESE LA is calculated according to French standard NFC 17-102, thus](https://reader033.fdocuments.us/reader033/viewer/2022060709/60758a774d68963e9159a8fe/html5/thumbnails/4.jpg)
www.vashudhaearthing.com
WHAT IS EARTHING?In electrical engineering, ground or earth (symbol: ⏚) can refer to the reference point in an electrical circuit
from which voltages are measured, a common return path for electric current, or a direct physical connection
to the Earth.
WHY EARTHING?Unfortunately, our electrical ecosystem is not perfect. It is constantly attacked by high voltages, fault currents,
surges, short circuits & lightning all of which can turn deadly. So, any structure which has electricity running
through it needs earthing for the protection of property and life.
What are the factors that determine the life of an earthing system?Since the earthing system works underground, lot of environmental factors come into play to decide the life of
the earthing system. They include
Soil conditions
Moisture content
Climate changes
Soil resistivity
Types of soil
(Normal, sandy, semi rocky, rocky etc.)
Acidity levels of the soil
Basic maintenance schedule
Apart from the above, it is very crucial that the installation of the earthing system is done as per specifications;
non adherence will not only drastically reduce service life of the system but also hinder earth resistance results.
![Page 5: SAVIOUR - 4.imimg.com4.imimg.com/data4/UQ/QT/MY-8496973/cl_bharti-enterprise.pdf · The protection area of Rp of ESE LA is calculated according to French standard NFC 17-102, thus](https://reader033.fdocuments.us/reader033/viewer/2022060709/60758a774d68963e9159a8fe/html5/thumbnails/5.jpg)
G E L E A R T H I N G E L E C T R O D E
A commitment for Genuine MaterialIt is important to remember that when you select Earthing Electrodes, M.O.C. (Metal of Conductor) is play a big
role. Specially for New era earthing electrode which is known as Chemical Earthing, Gel Earthing or
Maintenance Free Earthing, when you are selecting it, you are not selecting product, you are selecting a
solution. The quality of Gel earthing which is used to drive your valuables, Does it mean the difference between
HD-Hot Dip Galvanized Iron and Galvanized Iron? Major difference will occur in Electrode's life, in HDG and
Non-HDG Electrodes. Even in copper electrodes difference will occur in conductivity also.
Recent industry research has revealed that there are many products in the market that do not provide the HD
(Hot-Dip Galvanizing) which is very much affect to your earthing life and result in ohms value as well as for
them to perform properly. This is a result of poor manufacturing and the use of sub-standard components to
save production costs. The quality of your HD Electrodes also mean the difference between a safe and long life
earthing system.
Hot-Dip Galvanizing is the process of coating fabricated steel by immersing it in a bath of molten zinc. There
are three fundamental steps in the hot-dip galvanizing process; galvanizing and inspection.
GENUINE MATERIAL
Please check THE HOLOGRAM
for authentication
![Page 6: SAVIOUR - 4.imimg.com4.imimg.com/data4/UQ/QT/MY-8496973/cl_bharti-enterprise.pdf · The protection area of Rp of ESE LA is calculated according to French standard NFC 17-102, thus](https://reader033.fdocuments.us/reader033/viewer/2022060709/60758a774d68963e9159a8fe/html5/thumbnails/6.jpg)
www.vashudhaearthing.com
Shree Vasudha has developed –First ever GEL Earthing, The world class product is manufactured to replace the
traditional methods of earthing. After a consistent R&D and with over decades of expertise and a true backing
of almost 13-14 years of R & D has helped in evolve innovative cost effective & environment friendly solutions
for your grounding requirements under the registered brand name Shree Vasudha (Gel Earthing Electrode) &
our special hygroscopic compound named Shree Vasudha, Vasudha Plus and Vasudha Extra Plus. By utilizing
metal alloys and natural chemical compositions, the Gel Earthing Electrode is able to provide a multifaceted
proactive earthing protection strategy. The Earthing Electrode is manufactured from custom-made I.S.I tube
to ensure maximum conductivity and prolonged service life. The Gel Earthing Electrode contains a conductor
rich crystalline mixture that will protect the main earth electord in the soil. This will ensure a highly conductive
state for the fault current to pass on to earth.
SHREE VASHUDHA GEL EARTHING
WHAT IS BACK FILL COMPOUNDSWe have developed our unique back-fill-compound. Our unique back-fill-compound is a combination of
natural earth minerals, which having the hygroscopic property, to retain the moisture for a long time. During
Installation with proper water pouring, our B.F.C. powder convert into the “Gel” & its quality to retain the
moisture upto twenty times its dry volume as well as it create a gel layer surrounding of our electrode.
To achieve quality and cost-effective solution, we are having Vasudha, Vasudha Plus and Vasudha Extra Plus-
three different types of B.F.C.
Our B.F.C. is a combination of corrosion free and highly conductive minerals
![Page 7: SAVIOUR - 4.imimg.com4.imimg.com/data4/UQ/QT/MY-8496973/cl_bharti-enterprise.pdf · The protection area of Rp of ESE LA is calculated according to French standard NFC 17-102, thus](https://reader033.fdocuments.us/reader033/viewer/2022060709/60758a774d68963e9159a8fe/html5/thumbnails/7.jpg)
G E L E A R T H I N G E L E C T R O D E
EARLY STEAMER EMISSION LIGHTNING ARRESTOR (NFC 17-102)
LARGER ZONE OF PROTECTION Standard describes the main measures of the protecting buildings against direct lightning strokes using an early steamer emission lightning conductor. The Principal of protecting buildings against lightning is based on the electro-geometrical model.
In Early Steamer Emission Lightning Protection- a Lightning rod equipped with a system which creates the triggering advance of the upward ladder when compared with a simple rod (S.R.) Lightning conductor in the same conditions.
Rp
H
Simply, a Rod which does not having specific triggering advance device is not an Early Steamer Emission Lightning Arrester.
The protection area depends on a number of factors: Gain in triggering time T of the chosen ESE model. Depending on the protection level required on a given site, according to the lightning risk assessment guide (NFC 17-102) Actual height of the lightning air terminal above the surface area to be protected.
Shree Vasudha personnel and their associates have combined experience over many years in servicing customers on many type of projects of its lightning prone areas. We have vast experience in providing direct strike protection. Our experience is involved risk management, system design, installation and commissioning in key industries groups.
The protection area of Rp of ESE LA is calculated according to French standard NFC 17-102, thus
Rp= h(2D-H)+ L (2D+ L)
![Page 8: SAVIOUR - 4.imimg.com4.imimg.com/data4/UQ/QT/MY-8496973/cl_bharti-enterprise.pdf · The protection area of Rp of ESE LA is calculated according to French standard NFC 17-102, thus](https://reader033.fdocuments.us/reader033/viewer/2022060709/60758a774d68963e9159a8fe/html5/thumbnails/8.jpg)
www.vashudhaearthing.com
OUR PRODUCTS
Model No. Length (mm) Outer Dia(mm)
Internal Strip (mm) for SIP
Terminal Point (mm)
Internal Dia (mm) for PIP
VHD 19/2
VHD 19/3
VHD 39/2
VHD 39/3
2000
3000
2000
3000
46-50
46-50
76-80
76-80
38 X 6
38 X 6
65 X 6
65 X 6
12
12
14
14
22-25
22-25
37-40
37-40
Hot dip galvanized for corrosion protection
Pipe in pipe and strip in pipe design available
Designed for fast fault current dissipation
Most suitable for soil condition with pH value between 5.0 to 8.0
Crystalline conductive material filled
Long service life
HD GI Earthing Electrodes
Copper Bonded Rods
Wide applications
High Connectivity
Copper Bonded Earthing Electrodes
Model No. Length (mm) Outer Dia(mm)
Internal Strip (mm) for SIP
Terminal Point (mm)
Internal Dia (mm) for PIP
VCB 19/2
VCB 19/3
VCB 39/2
VCB 39/3
2000
3000
2000
3000
46-50
46-50
76-80
76-80
38 X 6
38 X 6
65 X 6
65 X 6
12
12
14
14
22-25
22-25
37-40
37-40
Excellent electrical conductivity and corrosion resistance
Pipe in pipe and Strip in pipe design available.
Crystalline conductive material filled
Long Service life
![Page 9: SAVIOUR - 4.imimg.com4.imimg.com/data4/UQ/QT/MY-8496973/cl_bharti-enterprise.pdf · The protection area of Rp of ESE LA is calculated according to French standard NFC 17-102, thus](https://reader033.fdocuments.us/reader033/viewer/2022060709/60758a774d68963e9159a8fe/html5/thumbnails/9.jpg)
G E L E A R T H I N G E L E C T R O D E
Copper Earthing Electrodes
Model No. Length (mm) Outer Dia(mm)
Internal Strip (mm) for SIP
Terminal Point (mm)
VC 19/2
VC 19/3
VC 60/2
VC 60/2
VC 39/2
VC 39/3
2000
3000
2000
3000
2000
3000
46-50
46-50
60-63
60-63
76-80
76-80
32 X 5
32 X 5
50 X 5
50 X 5
50 X 5
50 X 5
12
12
12
12
14
14
Best suited for harsh environments
Very high electrical conductivity and anti-corrosion properties.
Crystalline conductive material filled
Most suitable for soil condition with pH value between 5.0 to 8.0
Long service life
Franklin Lightning Arrester
Provides conical Protection MOC:
Copper, with required Spikes for buildings and Chimneys protection.
Back Fill Compound
Having all the properties which an ideal BFC should require. It helps to reducing
soil resistivity and retain moisture and works efficiently to dissipate the fault current.
Moisture is major factor in all earthing system, Shree Vasudha Extra Plus BFC
provides enough moisture and maintains for long time. When our Extra Plus Back fill
compound mixed with water, it convert in to semi permeable conductive gel foam
around the electrode. Specifically developed for relatively dry conditions.
12.5 kgs Bag Recommendation : 25 kgs BFC for 2 meter electrodes
50 kgs. BFC for 3 meter electrodes
![Page 10: SAVIOUR - 4.imimg.com4.imimg.com/data4/UQ/QT/MY-8496973/cl_bharti-enterprise.pdf · The protection area of Rp of ESE LA is calculated according to French standard NFC 17-102, thus](https://reader033.fdocuments.us/reader033/viewer/2022060709/60758a774d68963e9159a8fe/html5/thumbnails/10.jpg)
www.vashudhaearthing.com
Telecommunication Tower
Power Transmission Tower & HT/LT Lines
Power Generation Plants
Refineries Windmills
APPLICATION :
Homes Offices Mines High Rise Building Production Plants Transformers
ESE Lightning Arrester
Provides- Early steamer emission - parabolic protection early
prorogations benefit upto 107 meters radius of protection.
As per NFC 17-102 Norms
Incorporated with new technology
Tested at ITE (Institute for Energy Technology)
No maintenance, No additional power require
Working Actively in extreme rainy condition
With insulation system “Isolated System”
FRP Earth PIt Cover
Designed specifically for Earthing inspection Chamber. Durable
mild FRP cover and body, giving neat edge design. Solid tray
base.
TOP
150
150
BOTTOM
Length Width Height
190
180
190(Medal)
180(Corner)
Length Width Height
150
150
270
240
270(Medal)
240(Corner)
* The size of nos. of earthing electrodes should be recommend by your electrical consultant, engineers & contractors, depending on your infrastructure requirement. Ohmic value depends upon the soil & site conditions where ever it has to be used.
![Page 11: SAVIOUR - 4.imimg.com4.imimg.com/data4/UQ/QT/MY-8496973/cl_bharti-enterprise.pdf · The protection area of Rp of ESE LA is calculated according to French standard NFC 17-102, thus](https://reader033.fdocuments.us/reader033/viewer/2022060709/60758a774d68963e9159a8fe/html5/thumbnails/11.jpg)
G E L E A R T H I N G E L E C T R O D E
VHD 19 Model - We recommended this for LT application.
VHD 39 Model - We recommended this for HT application as well as lightning arrester application.
VC 19/39/60 Model - No-where only copper earthing is required.
2000 mm
3,14,000 sqmm
3000 mm
4,71,000 sqmm
3000 mm
7,53,600 sqmm
2000 mm
5,02,400 sqmm
3000 mm
5,93,460 sqmm
2000 mm
3,95,640 sqmm
V19 V39 V60
MAXIMUM SURFACE AREA:
INSTALLATION METHOD OF SHREE VASUDHA GEL EARTHING ELECTRODE
CAUTION
(1) Do not drop the Earthing Electrode. (2) Do not subject it to any kind of driving force. (3) Do not hammer it while installing the
Electrode. (4) Do not use it other than the purpose of Earthing. (5) Remove the thin plastic cover before installing the electrode. (6)
Always, place the Electrode keeping the connecting terminal on top. (7) Apply petroleum jelly over the exposed part (Terminal) of
the Electrodes to safe guard it against the corrosion.
Augur / Drill / Bore a hole of 8 - 10 Inch in diameter at a place where
earthing is to be done, to a suitable depth of 2 meters (Electrode Length)
Place the Earthing Electrode inside the pit
Mix the back fill compound nicely with the soil, which has been dug out.
Re-Fill the empty space around the Earthing Electrode with this compound
mix soil.
While re-filling the space, pour adequate water in the PIT intermittently.
Pack the soil around the Electrode tightly and nicely.
Again pour adequate water with using vibrator to create proper vacuum
at least 3 - 4 feet around the Earthing Electrode.
Test the earth resistivity of the Electrode and if the result is satisfactory,
then connect it with the equipments.
If the result is not satisfactory, then allow the Electrode some time(2/3
Weeks) for setting of the soil and then check it & connect it.
If the soil is of high resistivity i.e. Semi rocky or rocky soil, use back- fill
compound only for refilling the PIT.
Internal Strip
Outer Pipe
BFC
Filled CCM
Earth pit cover
VASUDHAS.E.E.
![Page 12: SAVIOUR - 4.imimg.com4.imimg.com/data4/UQ/QT/MY-8496973/cl_bharti-enterprise.pdf · The protection area of Rp of ESE LA is calculated according to French standard NFC 17-102, thus](https://reader033.fdocuments.us/reader033/viewer/2022060709/60758a774d68963e9159a8fe/html5/thumbnails/12.jpg)
OUR CLIENT
G E L E A R T H I N G E L E C T R O D E
“DHARKAN HOUSE”
New Balmukund Society Main Road,
Opp. Tagore School, B/h, Copper Height,
Off. Sadhu Vaswani Road, Rajkot - 360005.
GUJARAT (INDIA)
Ph. : 0281- 2577518, 2586457
Mo. : +91 85111 18512, 99980 09989
E-mail : [email protected]
Web. : www.vashudhaearthing.com
www.smartearthing.com
Cla
ssic
09327491973
HATHI MASALA
/vasudhaearthing