SISTEM PENDINGIN UTAMA
-
(CWP) Circulating Water PumpMemompa air laut sebagai supply air pendingin di condenser, cooling waterheat exchanger dan produksi chlorine
-
Condensortype : two passes, reverse floe, devided water box, horizontal surface typecondensate O2 content : 0.01 cc/lcirculating water capacity : 21,660 m3/hheat transfer coeffficient : 2.883 kcal/hwater velocity in tube : o,45 kg/cm2Ttotal efective tube surface : 10,590 m2
Range Operation
* Press. Condenser =65 mmHg AbsProtection * alarm vacuum low 635 mmHg* turbine trip 572 mmHg
-
(SWBP) Sea water Booster PumpMemmpa air laut dari discharge CWP menuju CWHE sebagai media pendingin air tawar
Spesification Pompa : * type : horisontal single suction volute* capacity : 20 m2/minMotor : * type : total enclosed fan cooled* capacity : 65 KW, 440 V, 112 A, 50 Hz, 6 pole Range Operation Temp : * bearing - grease motor = 55c- grease ring/pump = 40c* gland pompa = 40c* casing motor = 75cDiff. strainer high = 0.21 kg/cm2
-
(CWHE) Cooling Water Heat Excahangermedia pendingin paralatan air tawar pada area-area turbin, boiler, maupun auxillary lainnya