Lessons Learned from the Design & Operation of the First Full- Scale Post-Aerobic Digester (PAD)
Samuel Jeyanayagam, PhD, PE, BCEE, WEF FellowVice President & Regional WW Solutions Lead – US North
Bruce Johnson, PE, BCEE, IWA FellowWastewater Treatment Technology Fellow
29 Aug. 2018
![Page 2: Samuel Jeyanayagam,PhD, PE, BCEE, WEF Fellow€¦ · Samuel Jeyanayagam, PhD, PE, BCEE, WEF Fellow Vice President & Regional WW Solutions Lead –US North. Bruce Johnson, PE, BCEE,](https://reader035.fdocuments.us/reader035/viewer/2022062506/5f07cdd17e708231d41ed445/html5/thumbnails/2.jpg)
Safety Moment: Motion Induced Blindness
![Page 3: Samuel Jeyanayagam,PhD, PE, BCEE, WEF Fellow€¦ · Samuel Jeyanayagam, PhD, PE, BCEE, WEF Fellow Vice President & Regional WW Solutions Lead –US North. Bruce Johnson, PE, BCEE,](https://reader035.fdocuments.us/reader035/viewer/2022062506/5f07cdd17e708231d41ed445/html5/thumbnails/3.jpg)
Motion Induced Blindness
• When driving, if you fix your gaze on the road straight ahead, you may suffer a momentary loss of peripheral vision & may not see a vehicle or person approaching from the side.
• Always use the “eyes moving” technique when driving, to reduce the risk of motion induced blindness.
![Page 4: Samuel Jeyanayagam,PhD, PE, BCEE, WEF Fellow€¦ · Samuel Jeyanayagam, PhD, PE, BCEE, WEF Fellow Vice President & Regional WW Solutions Lead –US North. Bruce Johnson, PE, BCEE,](https://reader035.fdocuments.us/reader035/viewer/2022062506/5f07cdd17e708231d41ed445/html5/thumbnails/4.jpg)
Use “Eyes Moving” Technique
![Page 5: Samuel Jeyanayagam,PhD, PE, BCEE, WEF Fellow€¦ · Samuel Jeyanayagam, PhD, PE, BCEE, WEF Fellow Vice President & Regional WW Solutions Lead –US North. Bruce Johnson, PE, BCEE,](https://reader035.fdocuments.us/reader035/viewer/2022062506/5f07cdd17e708231d41ed445/html5/thumbnails/5.jpg)
Learning Objectives
• Explain the Post Aerobic Digestion (PAD) process• Describe the benefits of PAD• Recognize drivers for adopting PAD• Identify what it would take to implement PAD
![Page 6: Samuel Jeyanayagam,PhD, PE, BCEE, WEF Fellow€¦ · Samuel Jeyanayagam, PhD, PE, BCEE, WEF Fellow Vice President & Regional WW Solutions Lead –US North. Bruce Johnson, PE, BCEE,](https://reader035.fdocuments.us/reader035/viewer/2022062506/5f07cdd17e708231d41ed445/html5/thumbnails/6.jpg)
Presentation Outline
• What is PAD?• Benefits of PAD• Case Studies• Take Home Messages
![Page 7: Samuel Jeyanayagam,PhD, PE, BCEE, WEF Fellow€¦ · Samuel Jeyanayagam, PhD, PE, BCEE, WEF Fellow Vice President & Regional WW Solutions Lead –US North. Bruce Johnson, PE, BCEE,](https://reader035.fdocuments.us/reader035/viewer/2022062506/5f07cdd17e708231d41ed445/html5/thumbnails/7.jpg)
What is Post Aerobic Digestion (PAD)?
• Aerobic digestion after mesophilic anaerobic digestion
Aerobic DigesterAnaerobic
Digester
DewateringWAS + Primary Sludge
History• First investigated by Prof. John Novak (Virginia Tech)• Further developed by him working with Dr. Sudhir
Murthy (DCWater Innovations Team)
Licensing rights are owned by Ovivo
![Page 8: Samuel Jeyanayagam,PhD, PE, BCEE, WEF Fellow€¦ · Samuel Jeyanayagam, PhD, PE, BCEE, WEF Fellow Vice President & Regional WW Solutions Lead –US North. Bruce Johnson, PE, BCEE,](https://reader035.fdocuments.us/reader035/viewer/2022062506/5f07cdd17e708231d41ed445/html5/thumbnails/8.jpg)
• PAD tank is just an aerobic digester with respect to equipment
• PAD sludge age:– Typically, 5 to 10 days (driven by N removal requirements) – Longer SRT (20 d) provides higher VSR; but requires larger tank.
• Can reuse existing tankage• Can also serve as solids holding prior to dewatering• Heat generating process - digester contents are typically
around 35oC– May require cooling during warm summer conditions
Features of the PAD Process
![Page 9: Samuel Jeyanayagam,PhD, PE, BCEE, WEF Fellow€¦ · Samuel Jeyanayagam, PhD, PE, BCEE, WEF Fellow Vice President & Regional WW Solutions Lead –US North. Bruce Johnson, PE, BCEE,](https://reader035.fdocuments.us/reader035/viewer/2022062506/5f07cdd17e708231d41ed445/html5/thumbnails/9.jpg)
Benefits of PAD
1. Additional volatile solids removal (VSR)2. Sidestream treatment3. Struvite stabilization4. Enhanced dewaterability & reduced polymer use5. Reduced biosolids odor
![Page 10: Samuel Jeyanayagam,PhD, PE, BCEE, WEF Fellow€¦ · Samuel Jeyanayagam, PhD, PE, BCEE, WEF Fellow Vice President & Regional WW Solutions Lead –US North. Bruce Johnson, PE, BCEE,](https://reader035.fdocuments.us/reader035/viewer/2022062506/5f07cdd17e708231d41ed445/html5/thumbnails/10.jpg)
• Provides an additional 10 to 40% VSR across PAD
• Overall VSR (anaerobic + aerobic) can be >70%
• Reduced solids handling requirements and costs
* Novak et. al. (2009)
Volatile Solids Reduction (VSR)
![Page 11: Samuel Jeyanayagam,PhD, PE, BCEE, WEF Fellow€¦ · Samuel Jeyanayagam, PhD, PE, BCEE, WEF Fellow Vice President & Regional WW Solutions Lead –US North. Bruce Johnson, PE, BCEE,](https://reader035.fdocuments.us/reader035/viewer/2022062506/5f07cdd17e708231d41ed445/html5/thumbnails/11.jpg)
From Novak et. al (2009)
Avg. VSR =50% in meso. anaerobic digester; 20 d SRT
Avg. VSR = 62% in PAD
DC Water Results
![Page 12: Samuel Jeyanayagam,PhD, PE, BCEE, WEF Fellow€¦ · Samuel Jeyanayagam, PhD, PE, BCEE, WEF Fellow Vice President & Regional WW Solutions Lead –US North. Bruce Johnson, PE, BCEE,](https://reader035.fdocuments.us/reader035/viewer/2022062506/5f07cdd17e708231d41ed445/html5/thumbnails/12.jpg)
• They either remain attached to the cell's outer surface, or are secreted into the bulk liquid.
• EPS can constitute 50% to 90% of a biofilm's total organic matter
• Measured as VS
The Fate of Exocellular Polymer Substances is Central to PAD Performance
Some EPS, (e.g. those containing proteins called lectins) are degraded only aerobically
• Exocellular polymer substances (EPS) are natural polymers of high molecular weight secreted by microorganisms into their environment.
• EPSs are mostly composed of: Polysaccharides & Proteins DNA, Lipids, & Humic substances
• EPS are the construction material of bacterial cells
![Page 13: Samuel Jeyanayagam,PhD, PE, BCEE, WEF Fellow€¦ · Samuel Jeyanayagam, PhD, PE, BCEE, WEF Fellow Vice President & Regional WW Solutions Lead –US North. Bruce Johnson, PE, BCEE,](https://reader035.fdocuments.us/reader035/viewer/2022062506/5f07cdd17e708231d41ed445/html5/thumbnails/13.jpg)
• Anaerobic digestion releases significant amounts of ammonia & phosphate– Dewatering can return nutrient loads back to the head of the plant
• Low Flow ≈ 1% of influent flow• >800 mg/L Ammonia-N (15-40% of Infl. TN Load)• 100 – 700 mg/L Ortho-P (5-40% of Infl. TP Load)
• PAD can be operated to remove ammonia & nitrate:– Continuous aeration: Nitrification only (requires alkalinity addition). Ammonia
converted to nitrate, which will be in the centrate– Intermittent aeration or Low DO: Simultaneous nitrification denitrification (SND).
Remove ammonia & nitrate.• Benefits:
– Reduced recycle loads – Nitrifier bioaugmentation
Sidestream Treatment
At DC Water: • Ammonia removal from 2,500 mg/L to < 200 mg/L
at a 6 day SRT and 50/50 Aer/Non-aerated cycle• Nitrate < 200 mg/L
![Page 14: Samuel Jeyanayagam,PhD, PE, BCEE, WEF Fellow€¦ · Samuel Jeyanayagam, PhD, PE, BCEE, WEF Fellow Vice President & Regional WW Solutions Lead –US North. Bruce Johnson, PE, BCEE,](https://reader035.fdocuments.us/reader035/viewer/2022062506/5f07cdd17e708231d41ed445/html5/thumbnails/14.jpg)
• Struvite is Magnesium Ammonium Phosphate (MAP)• Forms because:
– Anaerobic digestion releases: Mg, NH3, & PO4
– Turbulence releases CO2 causing pH increase & struvite formation
• Nuisance struvite scaling in pipes & equipment can be an operational nightmare
• PAD stabilizes struvite formation in the high solids environment of the PAD tank– Struvite crystals are incorporated into the biosolids
stream & prevented from scaling piping & equipment– Down time & mitigation costs avoided– Phosphorus removal achieved
Struvite Stabilization
Chemical structure of struvite
![Page 15: Samuel Jeyanayagam,PhD, PE, BCEE, WEF Fellow€¦ · Samuel Jeyanayagam, PhD, PE, BCEE, WEF Fellow Vice President & Regional WW Solutions Lead –US North. Bruce Johnson, PE, BCEE,](https://reader035.fdocuments.us/reader035/viewer/2022062506/5f07cdd17e708231d41ed445/html5/thumbnails/15.jpg)
• EPS binds substantial amount of water in multiple structured layers.
• Results in gel-like consistency, which is difficult to extract during dewatering.
• PAD destroys EPS & allows:– More water to be removed– Dryer cake solids to be produced– Lower polymer consumption– Cost savings to be achieved
Dark rods are bacteria
Light areas around the cells are EPS
Dewaterability Enhancement
![Page 16: Samuel Jeyanayagam,PhD, PE, BCEE, WEF Fellow€¦ · Samuel Jeyanayagam, PhD, PE, BCEE, WEF Fellow Vice President & Regional WW Solutions Lead –US North. Bruce Johnson, PE, BCEE,](https://reader035.fdocuments.us/reader035/viewer/2022062506/5f07cdd17e708231d41ed445/html5/thumbnails/16.jpg)
• Spokane County WRF (Spokane, Washington, USA)• Northern Treatment Plant (Denver, Colorado, USA)• Boulder WWTP (Boulder, Colorado, USA
Case Studies
![Page 17: Samuel Jeyanayagam,PhD, PE, BCEE, WEF Fellow€¦ · Samuel Jeyanayagam, PhD, PE, BCEE, WEF Fellow Vice President & Regional WW Solutions Lead –US North. Bruce Johnson, PE, BCEE,](https://reader035.fdocuments.us/reader035/viewer/2022062506/5f07cdd17e708231d41ed445/html5/thumbnails/17.jpg)
• Greenfield, 8 MGD average, MBR facility• First started treating wastewater in late 2011• First full scale PAD plant in North America
Spokane County Regional Water Reclamation Facility (WRF)
![Page 18: Samuel Jeyanayagam,PhD, PE, BCEE, WEF Fellow€¦ · Samuel Jeyanayagam, PhD, PE, BCEE, WEF Fellow Vice President & Regional WW Solutions Lead –US North. Bruce Johnson, PE, BCEE,](https://reader035.fdocuments.us/reader035/viewer/2022062506/5f07cdd17e708231d41ed445/html5/thumbnails/18.jpg)
Centrifuge
Centrate
AnaerobicDigesters
Waste Solids
Raw
Chemically Enhanced Primary Treatment
Step Feed Bioreactor
Membranes
PAD
Spokane County Regional WRF
![Page 19: Samuel Jeyanayagam,PhD, PE, BCEE, WEF Fellow€¦ · Samuel Jeyanayagam, PhD, PE, BCEE, WEF Fellow Vice President & Regional WW Solutions Lead –US North. Bruce Johnson, PE, BCEE,](https://reader035.fdocuments.us/reader035/viewer/2022062506/5f07cdd17e708231d41ed445/html5/thumbnails/19.jpg)
• Two parallel mesophilic anaerobic digesters– Approx. 15 day SRT
• PAD– 5 to 10 days SRT with coarse bubble aeration– Provides additional VSR – Doubles as a solids storage tank when dewatering is not possible
(variable level)– Removes liquid phase inorganic nitrogen to less than 50 mg/L– Integral part of the nutrient removal system
Spokane Regional WRF PAD System
![Page 20: Samuel Jeyanayagam,PhD, PE, BCEE, WEF Fellow€¦ · Samuel Jeyanayagam, PhD, PE, BCEE, WEF Fellow Vice President & Regional WW Solutions Lead –US North. Bruce Johnson, PE, BCEE,](https://reader035.fdocuments.us/reader035/viewer/2022062506/5f07cdd17e708231d41ed445/html5/thumbnails/20.jpg)
Anaerobic Digestion
Thickening & Dewatering
CoGen & Gas Storage
Aerobic Digestion
Spokane Solids Handling System
![Page 21: Samuel Jeyanayagam,PhD, PE, BCEE, WEF Fellow€¦ · Samuel Jeyanayagam, PhD, PE, BCEE, WEF Fellow Vice President & Regional WW Solutions Lead –US North. Bruce Johnson, PE, BCEE,](https://reader035.fdocuments.us/reader035/viewer/2022062506/5f07cdd17e708231d41ed445/html5/thumbnails/21.jpg)
Biosolids handled decreased when PAD was in operation
PAD effluent NH3 decreased when PAD was in operation
PAD Performance at the Spokane Regional WRF
![Page 22: Samuel Jeyanayagam,PhD, PE, BCEE, WEF Fellow€¦ · Samuel Jeyanayagam, PhD, PE, BCEE, WEF Fellow Vice President & Regional WW Solutions Lead –US North. Bruce Johnson, PE, BCEE,](https://reader035.fdocuments.us/reader035/viewer/2022062506/5f07cdd17e708231d41ed445/html5/thumbnails/22.jpg)
Avg. rate of cumulative solids production decreased by 43% when PAD was in operation
Decreased by 12% when PAD was in operation
PAD Performance at the Spokane Regional WRF
![Page 23: Samuel Jeyanayagam,PhD, PE, BCEE, WEF Fellow€¦ · Samuel Jeyanayagam, PhD, PE, BCEE, WEF Fellow Vice President & Regional WW Solutions Lead –US North. Bruce Johnson, PE, BCEE,](https://reader035.fdocuments.us/reader035/viewer/2022062506/5f07cdd17e708231d41ed445/html5/thumbnails/23.jpg)
Operational DataAverages - Dec 2011 to Jan 2017
Ammonia-N TKN Nitrate/Nitrite-NAnaerobic Digester, mg/L ~900 ~2000
PAD, mg/L ~20 ~40
Removal Efficiency (PAD), % 98% 96% (TIN)
No supplement carbon or alkalinity addition needed
PAD Performance at the Spokane Regional WRF
![Page 24: Samuel Jeyanayagam,PhD, PE, BCEE, WEF Fellow€¦ · Samuel Jeyanayagam, PhD, PE, BCEE, WEF Fellow Vice President & Regional WW Solutions Lead –US North. Bruce Johnson, PE, BCEE,](https://reader035.fdocuments.us/reader035/viewer/2022062506/5f07cdd17e708231d41ed445/html5/thumbnails/24.jpg)
Overcoming Challenges at the First PAD Startup
• Temperature:– Air cooling system– Sprinklers (evaporative cooling) on aluminum lid– Automation and controls
• Foam:– Control temperature & process stability– Foam overflow system– Refining control over aeration cycles
• pH control – sulfuric acid addition
![Page 25: Samuel Jeyanayagam,PhD, PE, BCEE, WEF Fellow€¦ · Samuel Jeyanayagam, PhD, PE, BCEE, WEF Fellow Vice President & Regional WW Solutions Lead –US North. Bruce Johnson, PE, BCEE,](https://reader035.fdocuments.us/reader035/viewer/2022062506/5f07cdd17e708231d41ed445/html5/thumbnails/25.jpg)
Drivers for PAD• Sidestream Nitrogen Removal• Struvite Stabilization• Potential Dewatering Benefits
Northern Treatment PlantDenver, CO.
24 mgdDrivers for PAD• Use of Existing Infrastructure• Sidestream Nitrogen Removal• Reduce Disposal Cost• Struvite Stabilization• Potential Dewatering Benefits
Boulder WWTPBoulder, CO.
25 mgd
![Page 26: Samuel Jeyanayagam,PhD, PE, BCEE, WEF Fellow€¦ · Samuel Jeyanayagam, PhD, PE, BCEE, WEF Fellow Vice President & Regional WW Solutions Lead –US North. Bruce Johnson, PE, BCEE,](https://reader035.fdocuments.us/reader035/viewer/2022062506/5f07cdd17e708231d41ed445/html5/thumbnails/26.jpg)
• Baseline (No Sidestream Treatment) offers lowest capital cost
• Sidestream Treatment with PAD offers the lowest annual cost
• Equivalent life cycle costs for Baseline, PAD, and Anammox:– Consider PAD when using bio-P; TN removal; additional VSR;
and nuisance struvite mitigation are desired– Consider Anammox when N removal is desired and energy
minimization are desired.
Relative Costs
![Page 27: Samuel Jeyanayagam,PhD, PE, BCEE, WEF Fellow€¦ · Samuel Jeyanayagam, PhD, PE, BCEE, WEF Fellow Vice President & Regional WW Solutions Lead –US North. Bruce Johnson, PE, BCEE,](https://reader035.fdocuments.us/reader035/viewer/2022062506/5f07cdd17e708231d41ed445/html5/thumbnails/27.jpg)
• PAD is a new technology with significant benefits.• Key drivers for implementing PAD include the need to:
– Achieve additional VSR.– Provide chemical-free (alkalinity & carbon) sidestream treatment – Minimize struvite scaling potential.– Reduce cost of solids handling (higher cake solids & lower polymer use).
• PAD represents a relatively simple process conversion. If tankage is available, it can potentially provide a quick pay-back.
• Because PAD is a young technology, utilities interested in implementing PAD should stay abreast of lessons learned at operating facilities to fully understand plant-wide impacts.
Take Home Messages
![Page 28: Samuel Jeyanayagam,PhD, PE, BCEE, WEF Fellow€¦ · Samuel Jeyanayagam, PhD, PE, BCEE, WEF Fellow Vice President & Regional WW Solutions Lead –US North. Bruce Johnson, PE, BCEE,](https://reader035.fdocuments.us/reader035/viewer/2022062506/5f07cdd17e708231d41ed445/html5/thumbnails/28.jpg)
28
Questions?
![Page 29: Samuel Jeyanayagam,PhD, PE, BCEE, WEF Fellow€¦ · Samuel Jeyanayagam, PhD, PE, BCEE, WEF Fellow Vice President & Regional WW Solutions Lead –US North. Bruce Johnson, PE, BCEE,](https://reader035.fdocuments.us/reader035/viewer/2022062506/5f07cdd17e708231d41ed445/html5/thumbnails/29.jpg)
www.jacobs.com | worldwideDecember 27, 2018© Copyright Jacobs
Samuel Jeyanayagam, PhD, PE, BCEE, WEF FellowVice President & Regional WW Solutions Lead – US [email protected]
Bruce Johnson, PE, BCEE, IWA FellowWastewater Treatment Technology Fellow
Lessons Learned from the Design & Operation of the First Full- Scale Post-Aerobic Digester (PAD)
29 Aug. 2018