SAMPLE OF COOLING LOAD ESTIMATION WITH HAP

96
SAMPLE OF COOLING LOAD ESTIMATION WITH HAP

Transcript of SAMPLE OF COOLING LOAD ESTIMATION WITH HAP

Page 1: SAMPLE OF COOLING LOAD ESTIMATION WITH HAP

SAMPLE OF COOLING LOAD ESTIMATION WITH HAP

Page 2: SAMPLE OF COOLING LOAD ESTIMATION WITH HAP

HOURLY ANALYSIS PROGRAM (HAP)

◼ HAP SYSTEM DESIGN FEATURES.

◼ HAP ENERGY ANALYSIS FEATURES.

◼ USING HAP TO DESIGN SYSTEMS AND PLANTS.

◼ USING HAP TO ESTIMATE ENERGY USE AND COST.

◼ WORKING WITH PROJECTS.

◼ GENERATING INPUT DATA REPORTS.

◼ USING THE REPORT VIEWER .

Page 3: SAMPLE OF COOLING LOAD ESTIMATION WITH HAP

HOW TO START?

◼ From START MENU choose Hourly Analysis Program (HAP).

Page 4: SAMPLE OF COOLING LOAD ESTIMATION WITH HAP
Page 5: SAMPLE OF COOLING LOAD ESTIMATION WITH HAP

Click on (HAP) starting window will appear.

Page 6: SAMPLE OF COOLING LOAD ESTIMATION WITH HAP
Page 7: SAMPLE OF COOLING LOAD ESTIMATION WITH HAP

Create a New Project

Choose new on the PROJECT MENU this creates a NEW PROJECT a project is the container which holds your data.

Page 8: SAMPLE OF COOLING LOAD ESTIMATION WITH HAP
Page 9: SAMPLE OF COOLING LOAD ESTIMATION WITH HAP

New project will be established which will be contain" SAMPLE DATA. "

Page 10: SAMPLE OF COOLING LOAD ESTIMATION WITH HAP
Page 11: SAMPLE OF COOLING LOAD ESTIMATION WITH HAP

Choose Save on the Project menu you’ll be asked to name the

project from here on, save the project periodically.

Page 12: SAMPLE OF COOLING LOAD ESTIMATION WITH HAP
Page 13: SAMPLE OF COOLING LOAD ESTIMATION WITH HAP

ENTER WEATHER DATA

Click on the “Weather” item in the tree view

in the main program window. The Weather input form will appear .

Page 14: SAMPLE OF COOLING LOAD ESTIMATION WITH HAP
Page 15: SAMPLE OF COOLING LOAD ESTIMATION WITH HAP

Select MIDDLE EAST region.

Page 16: SAMPLE OF COOLING LOAD ESTIMATION WITH HAP
Page 17: SAMPLE OF COOLING LOAD ESTIMATION WITH HAP

from location menu select EGYPT.

Page 18: SAMPLE OF COOLING LOAD ESTIMATION WITH HAP
Page 19: SAMPLE OF COOLING LOAD ESTIMATION WITH HAP

from CITY MENU select CAIRO.

Page 20: SAMPLE OF COOLING LOAD ESTIMATION WITH HAP
Page 21: SAMPLE OF COOLING LOAD ESTIMATION WITH HAP

Press the OK button on the Weather input form to save the data and return to the main program window.

Page 22: SAMPLE OF COOLING LOAD ESTIMATION WITH HAP

Enter Space Data General(General)Click on the “Space” item in the tree view

in the main program window. Space information will appear in the list view double-click on the “<new default space>” item in the list view.

Page 23: SAMPLE OF COOLING LOAD ESTIMATION WITH HAP
Page 24: SAMPLE OF COOLING LOAD ESTIMATION WITH HAP

Enter data for your space.

◼ -Naming the space.

◼ -Input floor area, average ceiling height and building weight.

Page 25: SAMPLE OF COOLING LOAD ESTIMATION WITH HAP
Page 26: SAMPLE OF COOLING LOAD ESTIMATION WITH HAP

INTERNAL LOAD

Page 27: SAMPLE OF COOLING LOAD ESTIMATION WITH HAP
Page 28: SAMPLE OF COOLING LOAD ESTIMATION WITH HAP

Entering overhead lighting

◼ -select recessed unvented as fixture type, as lighting intensityand ballast multiplier as default.

Page 29: SAMPLE OF COOLING LOAD ESTIMATION WITH HAP
Page 30: SAMPLE OF COOLING LOAD ESTIMATION WITH HAP

Create Schedules.

◼ When entering overhead lighting data, you must choose a schedule. In the schedule drop-down list, choose the" create new schedule”

Page 31: SAMPLE OF COOLING LOAD ESTIMATION WITH HAP
Page 32: SAMPLE OF COOLING LOAD ESTIMATION WITH HAP

LIGHT SCHEDULES WINDOW WILL APPEAR.

Page 33: SAMPLE OF COOLING LOAD ESTIMATION WITH HAP
Page 34: SAMPLE OF COOLING LOAD ESTIMATION WITH HAP

There are two different profiles which the space working

Page 35: SAMPLE OF COOLING LOAD ESTIMATION WITH HAP

Working day profile

Page 36: SAMPLE OF COOLING LOAD ESTIMATION WITH HAP

Day off profile

Page 37: SAMPLE OF COOLING LOAD ESTIMATION WITH HAP

Finally choose ROOM LIGHTING schedule

Page 38: SAMPLE OF COOLING LOAD ESTIMATION WITH HAP
Page 39: SAMPLE OF COOLING LOAD ESTIMATION WITH HAP

ENTERING EQUIPMENT .

◼ Create Schedules, when entering equipment data, you must choose a schedule. In the schedule drop-down list, choose the “create new schedule”

Page 40: SAMPLE OF COOLING LOAD ESTIMATION WITH HAP
Page 41: SAMPLE OF COOLING LOAD ESTIMATION WITH HAP

There are two different profiles which the space working

Page 42: SAMPLE OF COOLING LOAD ESTIMATION WITH HAP
Page 43: SAMPLE OF COOLING LOAD ESTIMATION WITH HAP

Finally choose equipment schedule

Page 44: SAMPLE OF COOLING LOAD ESTIMATION WITH HAP
Page 45: SAMPLE OF COOLING LOAD ESTIMATION WITH HAP

ENTERING PEOPLE .

◼ Create Schedules, when entering people data, you must choose activity level .

Page 46: SAMPLE OF COOLING LOAD ESTIMATION WITH HAP
Page 47: SAMPLE OF COOLING LOAD ESTIMATION WITH HAP

Create Schedules.

◼ when entering equipment data, you must choose a schedule. In the schedule drop-down list, choose the “create new schedule”

Page 48: SAMPLE OF COOLING LOAD ESTIMATION WITH HAP
Page 49: SAMPLE OF COOLING LOAD ESTIMATION WITH HAP

There are two different profiles which the space

working

Page 50: SAMPLE OF COOLING LOAD ESTIMATION WITH HAP
Page 51: SAMPLE OF COOLING LOAD ESTIMATION WITH HAP

Finally choose PEOPLE schedule.

Page 52: SAMPLE OF COOLING LOAD ESTIMATION WITH HAP
Page 53: SAMPLE OF COOLING LOAD ESTIMATION WITH HAP

ENTERING WALL, WINDOWS AND DOORS DETAILS

◼ choose direction of exposure wall

Page 54: SAMPLE OF COOLING LOAD ESTIMATION WITH HAP
Page 55: SAMPLE OF COOLING LOAD ESTIMATION WITH HAP

CHOOSE LAYERS OF WALL

Page 56: SAMPLE OF COOLING LOAD ESTIMATION WITH HAP
Page 57: SAMPLE OF COOLING LOAD ESTIMATION WITH HAP

ENTERING ROOF DATA

Page 58: SAMPLE OF COOLING LOAD ESTIMATION WITH HAP
Page 59: SAMPLE OF COOLING LOAD ESTIMATION WITH HAP

choose direction of roof.

Page 60: SAMPLE OF COOLING LOAD ESTIMATION WITH HAP
Page 61: SAMPLE OF COOLING LOAD ESTIMATION WITH HAP

choose layer of roof .

Page 62: SAMPLE OF COOLING LOAD ESTIMATION WITH HAP
Page 63: SAMPLE OF COOLING LOAD ESTIMATION WITH HAP

ENTERING INFILTRATION DATA

Page 64: SAMPLE OF COOLING LOAD ESTIMATION WITH HAP
Page 65: SAMPLE OF COOLING LOAD ESTIMATION WITH HAP

ENTERING FLOOR TYPE DATA

Page 66: SAMPLE OF COOLING LOAD ESTIMATION WITH HAP
Page 67: SAMPLE OF COOLING LOAD ESTIMATION WITH HAP

ENTERING PARTITION

DETAILS

Page 68: SAMPLE OF COOLING LOAD ESTIMATION WITH HAP
Page 69: SAMPLE OF COOLING LOAD ESTIMATION WITH HAP

ENTER AIR SYSTEM DATA

◼ Click on the “System” item in the

tree view in the main program window. System information will appear in the list view.

◼ Double-click on the “<new default system>” item in the list view. The

System input form will appear

Page 70: SAMPLE OF COOLING LOAD ESTIMATION WITH HAP
Page 71: SAMPLE OF COOLING LOAD ESTIMATION WITH HAP

General

Naming the system

Page 72: SAMPLE OF COOLING LOAD ESTIMATION WITH HAP
Page 73: SAMPLE OF COOLING LOAD ESTIMATION WITH HAP

Select “Chilled Water Air Handling Units” as equipment type .

Page 74: SAMPLE OF COOLING LOAD ESTIMATION WITH HAP
Page 75: SAMPLE OF COOLING LOAD ESTIMATION WITH HAP

Select “VAV” as air system type

Page 76: SAMPLE OF COOLING LOAD ESTIMATION WITH HAP
Page 77: SAMPLE OF COOLING LOAD ESTIMATION WITH HAP

SYSTEM COMPONENT DATA

Ventilation air system

Page 78: SAMPLE OF COOLING LOAD ESTIMATION WITH HAP
Page 79: SAMPLE OF COOLING LOAD ESTIMATION WITH HAP

Central Cooling Data

Page 80: SAMPLE OF COOLING LOAD ESTIMATION WITH HAP
Page 81: SAMPLE OF COOLING LOAD ESTIMATION WITH HAP

SUPPLY FAN

Page 82: SAMPLE OF COOLING LOAD ESTIMATION WITH HAP
Page 83: SAMPLE OF COOLING LOAD ESTIMATION WITH HAP

Duct System Data

Page 84: SAMPLE OF COOLING LOAD ESTIMATION WITH HAP
Page 85: SAMPLE OF COOLING LOAD ESTIMATION WITH HAP

Zone Components

Space Assignments

Page 86: SAMPLE OF COOLING LOAD ESTIMATION WITH HAP
Page 87: SAMPLE OF COOLING LOAD ESTIMATION WITH HAP

THERMOSTATS

Page 88: SAMPLE OF COOLING LOAD ESTIMATION WITH HAP
Page 89: SAMPLE OF COOLING LOAD ESTIMATION WITH HAP

Sizing Data

Sizing Specification

Page 90: SAMPLE OF COOLING LOAD ESTIMATION WITH HAP
Page 91: SAMPLE OF COOLING LOAD ESTIMATION WITH HAP

ZONE SIZING

Page 92: SAMPLE OF COOLING LOAD ESTIMATION WITH HAP
Page 93: SAMPLE OF COOLING LOAD ESTIMATION WITH HAP

TO PREVIEW OUTPUT REPORT

From Reports menu choose (Print/View Design Data)

Page 94: SAMPLE OF COOLING LOAD ESTIMATION WITH HAP
Page 95: SAMPLE OF COOLING LOAD ESTIMATION WITH HAP

The output Reports window will appear and we choose any output data

Page 96: SAMPLE OF COOLING LOAD ESTIMATION WITH HAP