7
Date received: 06/10/14 Date of issue: 04/11/14 Report consists of 5 test reports. Sample name: ANJA SAMPLE N° 183991 List performed tests: 1. Drop test - Dynamic - ANSI- BIFMA X5.1-2011/8 2. Stability test ANSI-BIFMA X5.1-2011/12 3. Leg strength test - Front application ANSI-BIFMA X5.1-2011/18 4. Leg strength test - Side application ANSI-BIFMA X5.1-2011/18 5. Seating durability test - Cyclic - ANSI-BIFMA X5.1-2011/11 CANTARUTTI S.R.L. VIA MAGGIORE 14 33040 PREMARIACCO (UD) ITALIA The sample name and, when relevant, its description, are given by the orderer, and CATAS does not assume responsibility on this matter. This test report relates to the sample submitted for the test and no others. Additions, deletions or alterations are not permitted. This test report must always be reproduced in its entirety. Unless otherwise stated, sampling has been carried out by the orderer. Page 1 of 2 This document is validated by digital signature and time stamping in accordance with the Italian laws and the European Directives which regulate the electronic signature systems. Managing Director Dr. Andrea Giavon Defects before testing: None Overall dimensions: 460 x 460 x 830 (h) mm CATAS S.p.A. Iscr. Reg. Imprese Udine nr. iscr. C.F. 01818850305 Reg. Impr. UD 20663 P. IVA : 01818850305 C.Soc. 1.003.650,00 i.v. centro ricerche-sviluppo e laboratori prove settori legno-arredo, ambiente e alimenti Sede: Via Antica, 24/3 33048 S. Giovanni al Nat. UD Tel. 0432.747211 r.a. Fax 0432.747250 http://www.catas.com e-mail: [email protected] Filiale: Via Braille, 5 20851 Lissone MB Tel. 039.464567 Fax 039.464565 e-mail: [email protected]

Transcript of SAMPLE N° 183991 - JR Furniturejamesrichardsonfurniture.com.au/app/themes/jrfurniture/...TEST...

Page 1: SAMPLE N° 183991 - JR Furniturejamesrichardsonfurniture.com.au/app/themes/jrfurniture/...TEST REPORT 183991 / 3 Date received: 06/10/14 Date of test: 09/10/14 Date of issue: 04/11/14

Date received: 06/10/14

Date of issue: 04/11/14

Report consists of 5 test reports.

Sample name: ANJA

SAMPLE N° 183991

List performed tests:1. Drop test - Dynamic - ANSI- BIFMA X5.1-2011/8 2. Stability test ANSI-BIFMA X5.1-2011/12 3. Leg strength test - Front application ANSI-BIFMA X5.1-2011/18 4. Leg strength test - Side application ANSI-BIFMA X5.1-2011/18 5. Seating durability test - Cyclic - ANSI-BIFMA X5.1-2011/11

CANTARUTTI S.R.L. VIA MAGGIORE 14 33040 PREMARIACCO (UD) ITALIA

The sample name and, when relevant, its description, are given by the orderer, and CATAS does not assume responsibility on this matter. This test report relates to the sample submitted for the test and no others. Additions, deletions or alterations are not permitted. This test report must always be reproduced in its entirety. Unless otherwise stated, sampling has been carried out by the orderer.

Page 1 of 2

This document is validated by digital signature and time stamping in accordance with the Italian laws and the European Directives which regulate the electronic signature systems.

Managing Director Dr. Andrea Giavon

Defects before testing: None

Overall dimensions: 460 x 460 x 830 (h) mm

CATAS S.p.A. Iscr. Reg. Imprese Udine nr. iscr. C.F. 01818850305 Reg. Impr. UD 20663 P. IVA : 01818850305 C.Soc. € 1.003.650,00 i.v.

centro ricerche-sviluppo e laboratori prove settori legno-arredo, ambiente e alimenti

Sede: Via Antica, 24/3 33048 S. Giovanni al Nat. UD Tel. 0432.747211 r.a. Fax 0432.747250 http://www.catas.com e-mail: [email protected]

Filiale: Via Braille, 5 20851 Lissone MB Tel. 039.464567 Fax 039.464565 e-mail: [email protected]

Page 2: SAMPLE N° 183991 - JR Furniturejamesrichardsonfurniture.com.au/app/themes/jrfurniture/...TEST REPORT 183991 / 3 Date received: 06/10/14 Date of test: 09/10/14 Date of issue: 04/11/14

Date of issue: 04/11/14

Sample name: ANJA

SAMPLE N° 183991

Page 2 of 2

The sample name and, when relevant, its description, are given by the orderer, and CATAS does not assume responsibility on this matter. This test report relates to the sample submitted for the test and no others. Additions, deletions or alterations are not permitted. This test report must always be reproduced in its entirety. Unless otherwise stated, sampling has been carried out by the orderer.

Side view Rear view

Bottom view

Sample weight: Not determined

CATAS S.p.A. Iscr. Reg. Imprese Udine nr. iscr. C.F. 01818850305 Reg. Impr. UD 20663 P. IVA : 01818850305 C.Soc. € 1.003.650,00 i.v.

centro ricerche-sviluppo e laboratori prove settori legno-arredo, ambiente e alimenti

Sede: Via Antica, 24/3 33048 S. Giovanni al Nat. UD Tel. 0432.747211 r.a. Fax 0432.747250 http://www.catas.com e-mail: [email protected]

Filiale: Via Braille, 5 20851 Lissone MB Tel. 039.464567 Fax 039.464565 e-mail: [email protected]

Page 3: SAMPLE N° 183991 - JR Furniturejamesrichardsonfurniture.com.au/app/themes/jrfurniture/...TEST REPORT 183991 / 3 Date received: 06/10/14 Date of test: 09/10/14 Date of issue: 04/11/14

TEST REPORT

183991 / 1Date received: 06/10/14Date of test: 09/10/14Date of issue: 04/11/14Sample name: ANJA

Drop test - Dynamic - ANSI- BIFMA X5.1-2011/8

CANTARUTTI S.R.L.!VIA MAGGIORE 14!33040 PREMARIACCO (UD)!ITALIA

CATAS S.p.A. Iscr. Reg. Imprese Udine nr. iscr. C.F. 01818850305 Reg. Impr. UD 20663 P. IVA : 01818850305 C.Soc. € 1.003.650,00 i.v.

centro ricerche-sviluppo e laboratori prove settori legno-arredo, ambiente e alimenti

Sede: Via Antica, 24/3 33048 S. Giovanni al Nat. UD Tel. 0432.747211 r.a. Fax 0432.747250 http://www.catas.com e-mail: [email protected]

Filiale: Via Braille, 5 20851 Lissone MB Tel. 039.464567 Fax 039.464565 e-mail: [email protected]

Height of drop: 152 mm above the uncompressed seat surface

Remarks

Test results:

Number!of drops

Bag weight!kg

102 1 No defects

136 1 No defects

Test passed

pag. 1/1

The sample name and, when relevant, its description, are given by the orderer, and CATAS does not assume responsibility on this matter. This test report relates to the sample submitted for the test and no others. Additions, deletions or alterations are not permitted. This test report must always be reproduced in its entirety. Unless otherwise stated, sampling has been carried out by the orderer.

This document is validated by digital signature and time stamping in accordance with the Italian laws and the European Directives which regulate the electronic signature systems.

Managing Director Dr. Andrea Giavon

Page 4: SAMPLE N° 183991 - JR Furniturejamesrichardsonfurniture.com.au/app/themes/jrfurniture/...TEST REPORT 183991 / 3 Date received: 06/10/14 Date of test: 09/10/14 Date of issue: 04/11/14

TEST REPORT

183991 / 2Date received: 06/10/14Date of test: 09/10/14Date of issue: 04/11/14Sample name: ANJA

Stability test ANSI-BIFMA X5.1-2011/12

CANTARUTTI S.R.L.!VIA MAGGIORE 14!33040 PREMARIACCO (UD)!ITALIA

CATAS S.p.A. Iscr. Reg. Imprese Udine nr. iscr. C.F. 01818850305 Reg. Impr. UD 20663 P. IVA : 01818850305 C.Soc. € 1.003.650,00 i.v.

centro ricerche-sviluppo e laboratori prove settori legno-arredo, ambiente e alimenti

Sede: Via Antica, 24/3 33048 S. Giovanni al Nat. UD Tel. 0432.747211 r.a. Fax 0432.747250 http://www.catas.com e-mail: [email protected]

Filiale: Via Braille, 5 20851 Lissone MB Tel. 039.464567 Fax 039.464565 e-mail: [email protected]

Type of chair: Type III

Forza min. amm. 143,372

Rear stability for chair type III60 kg

Altezza sedile 465 Seat load: Minimum force required: 143 N Measured force: 158 N

Rear stability for chair type I and II/

N

Loading discs on the seatNote: /

600Front stability Vertical load: Minimum force required: 20 N Measured force: > 20 N

Test passed

pag. 1/1

The sample name and, when relevant, its description, are given by the orderer, and CATAS does not assume responsibility on this matter. This test report relates to the sample submitted for the test and no others. Additions, deletions or alterations are not permitted. This test report must always be reproduced in its entirety. Unless otherwise stated, sampling has been carried out by the orderer.

This document is validated by digital signature and time stamping in accordance with the Italian laws and the European Directives which regulate the electronic signature systems.

Managing Director Dr. Andrea Giavon

Page 5: SAMPLE N° 183991 - JR Furniturejamesrichardsonfurniture.com.au/app/themes/jrfurniture/...TEST REPORT 183991 / 3 Date received: 06/10/14 Date of test: 09/10/14 Date of issue: 04/11/14

TEST REPORT

183991 / 3Date received: 06/10/14Date of test: 09/10/14Date of issue: 04/11/14Sample name: ANJA

Leg strength test - Front application ANSI-BIFMA X5.1-2011/18

CANTARUTTI S.R.L.!VIA MAGGIORE 14!33040 PREMARIACCO (UD)!ITALIA

CATAS S.p.A. Iscr. Reg. Imprese Udine nr. iscr. C.F. 01818850305 Reg. Impr. UD 20663 P. IVA : 01818850305 C.Soc. € 1.003.650,00 i.v.

centro ricerche-sviluppo e laboratori prove settori legno-arredo, ambiente e alimenti

Sede: Via Antica, 24/3 33048 S. Giovanni al Nat. UD Tel. 0432.747211 r.a. Fax 0432.747250 http://www.catas.com e-mail: [email protected]

Filiale: Via Braille, 5 20851 Lissone MB Tel. 039.464567 Fax 039.464565 e-mail: [email protected]

Test results:

Applied!load!

N

Load!application points!

mm

Time of!application!

minutesRemarksLeg

Right leg 334 38 from the bottom !and 25 from the edge 1 No defects

Left leg 334 38 from the bottom !and 25 from the edge 1 No defects

LegApplied!

load!N

Load!application points!

mm

Time of!application!

minutesRemarks

Right leg 503 38 from the bottom !and 25 from the edge 1 No defects

Left leg 503 38 from the bottom !and 25 from the edge 1 No defects

Test passed

pag. 1/1

The sample name and, when relevant, its description, are given by the orderer, and CATAS does not assume responsibility on this matter. This test report relates to the sample submitted for the test and no others. Additions, deletions or alterations are not permitted. This test report must always be reproduced in its entirety. Unless otherwise stated, sampling has been carried out by the orderer.

This document is validated by digital signature and time stamping in accordance with the Italian laws and the European Directives which regulate the electronic signature systems.

Managing Director Dr. Andrea Giavon

Page 6: SAMPLE N° 183991 - JR Furniturejamesrichardsonfurniture.com.au/app/themes/jrfurniture/...TEST REPORT 183991 / 3 Date received: 06/10/14 Date of test: 09/10/14 Date of issue: 04/11/14

TEST REPORT

183991 / 4Date received: 06/10/14Date of test: 09/10/14Date of issue: 04/11/14Sample name: ANJA

Leg strength test - Side application ANSI-BIFMA X5.1-2011/18

CANTARUTTI S.R.L.!VIA MAGGIORE 14!33040 PREMARIACCO (UD)!ITALIA

CATAS S.p.A. Iscr. Reg. Imprese Udine nr. iscr. C.F. 01818850305 Reg. Impr. UD 20663 P. IVA : 01818850305 C.Soc. € 1.003.650,00 i.v.

centro ricerche-sviluppo e laboratori prove settori legno-arredo, ambiente e alimenti

Sede: Via Antica, 24/3 33048 S. Giovanni al Nat. UD Tel. 0432.747211 r.a. Fax 0432.747250 http://www.catas.com e-mail: [email protected]

Filiale: Via Braille, 5 20851 Lissone MB Tel. 039.464567 Fax 039.464565 e-mail: [email protected]

Test results:

Applied!load!

N

Load!application points!

mm

Time of!application!

minutesRemarksLeg

Front leg 334 38 from the bottom !and 25 from the edge 1 No defects

Rear leg 334 38 from the bottom !and 25 from the edge 1 No defects

LegApplied!

load!N

Load!application points!

mm

Time of!application!

minutesRemarks

Front leg 503 38 from the bottom !and 25 from the edge 1 No defects

Rear leg 503 38 from the bottom !and 25 from the edge 1 No defects

Test passed

pag. 1/1

The sample name and, when relevant, its description, are given by the orderer, and CATAS does not assume responsibility on this matter. This test report relates to the sample submitted for the test and no others. Additions, deletions or alterations are not permitted. This test report must always be reproduced in its entirety. Unless otherwise stated, sampling has been carried out by the orderer.

This document is validated by digital signature and time stamping in accordance with the Italian laws and the European Directives which regulate the electronic signature systems.

Managing Director Dr. Andrea Giavon

Page 7: SAMPLE N° 183991 - JR Furniturejamesrichardsonfurniture.com.au/app/themes/jrfurniture/...TEST REPORT 183991 / 3 Date received: 06/10/14 Date of test: 09/10/14 Date of issue: 04/11/14

TEST REPORT

183991 / 5Date received: 06/10/14Date of test: 27/10/14Date of issue: 04/11/14Sample name: ANJA

Seating durability test - Cyclic - ANSI-BIFMA X5.1-2011/11

CANTARUTTI S.R.L.!VIA MAGGIORE 14!33040 PREMARIACCO (UD)!ITALIA

CATAS S.p.A. Iscr. Reg. Imprese Udine nr. iscr. C.F. 01818850305 Reg. Impr. UD 20663 P. IVA : 01818850305 C.Soc. € 1.003.650,00 i.v.

centro ricerche-sviluppo e laboratori prove settori legno-arredo, ambiente e alimenti

Sede: Via Antica, 24/3 33048 S. Giovanni al Nat. UD Tel. 0432.747211 r.a. Fax 0432.747250 http://www.catas.com e-mail: [email protected]

Filiale: Via Braille, 5 20851 Lissone MB Tel. 039.464567 Fax 039.464565 e-mail: [email protected]

Seat impact test

30 mm above the uncompressed seat surface

Remarks

Height of drop:

Test results:

Number!of drops

Mass of drop!kg

57 100.000 No defects

Front corner load-ease test - cyclic -off-center

Number!of cycles Remarks

Test results:

Seat load !N

734 20.000 No defects

Test passed

pag. 1/1

The sample name and, when relevant, its description, are given by the orderer, and CATAS does not assume responsibility on this matter. This test report relates to the sample submitted for the test and no others. Additions, deletions or alterations are not permitted. This test report must always be reproduced in its entirety. Unless otherwise stated, sampling has been carried out by the orderer.

This document is validated by digital signature and time stamping in accordance with the Italian laws and the European Directives which regulate the electronic signature systems.

Managing Director Dr. Andrea Giavon