RV Park Equipment - Cesco.comRV Park Equipment SURFACE - UNMETERED 3 U055C010 (Fig. M) 20 5-20R2GFI...

28

Transcript of RV Park Equipment - Cesco.comRV Park Equipment SURFACE - UNMETERED 3 U055C010 (Fig. M) 20 5-20R2GFI...

Page 1: RV Park Equipment - Cesco.comRV Park Equipment SURFACE - UNMETERED 3 U055C010 (Fig. M) 20 5-20R2GFI 2020 S P A C E (2) 5-20R2GFI U011C010 (Fig. C) 5-20R2 U010G (Fig. B) 20 GFI U040G
Page 2: RV Park Equipment - Cesco.comRV Park Equipment SURFACE - UNMETERED 3 U055C010 (Fig. M) 20 5-20R2GFI 2020 S P A C E (2) 5-20R2GFI U011C010 (Fig. C) 5-20R2 U010G (Fig. B) 20 GFI U040G

Today, most RV Parks provide electrical power for their tenants. This application presents unique requirements including user safety, rugged construction, weather protection and receptacle versatility. Midwest Electric offers a complete line of power outlet products for RV Park applications including standard power outlets, post mounted units, and metered models for both surface and pedestal units.

APPLICATION INFORMATIONRV Park Equipment

2

The 2002 National Electric Code Requires:

551-71. Type Receptacles Provided. Every recreational vehicle site with electrical supply shall be equipped with at least one 20-ampere, 125-volt receptacle. A minimum of 5 percent of all recreational vehicle sites with electrical supply, shall each be equipped with a 50-ampere, 125/250 volt receptacle conforming to the configuration as identified in Figure 551-46(c). These electrical supplies shall be permitted to include additional recep-tacles that have configurations in accordance with Section 551-81. A minimum of 70 percent of all recreational vehicle sites with electrical supply shall each be equipped with a 30-ampere, 125-volt receptacle conforming to Figure 551-46(c). This supply shall be permitted to include additional receptacle configurations conforming to Section 551-81. The remainder of all recreational vehicle sties with electrical supply shall be equipped with one or more of the receptacle configurations conforming to Section 551-81. Dedicated tent sites with a 15- or 20-ampere electrical supply shall be permitted to be excluded when determining the percentage of recreational vehicle sites with 30- or 50- ampere receptacles.

Additional receptacles shall be permitted for the connection of electrical equipment outside the recreational vehicle within the recreational vehicle park.

All 125-volt, single-phase, 15- and 20-ampere receptacles shall have listed ground-fault circuit-interrupter protection for personnel.

Figure 551-46(c). Configurations for grounding-type receptacles and attachment plug caps used for recreational vehicle supply cords and recreational vehicle lots.

551-77(b). Disconnecting Means. A disconnecting switch or circuit breaker shall be provided in the site supply equipment for disconnecting the power supply to the recreational vehicle.

Recreational Vehicle Parks are typically wired using either a loop-feed or radial-feed system as illustrated below. The most popular, and generally most economical, is the loop-feed system where each feeder services a single power outlet.

Midwest Electric offers a complete line of power outlets for recreational vehicle park application that meet the National Electrical Code: standard power outlets, post mounted power outlets (completely factory assembled and wired with loop-feed lugs in the post) and metered power outlets (ring-type and ringless). Also listed are surface mounted models with twin lugs per phase ideal for overhead loop-feed systems.

Midwest offers both the traditional metallic equip-ment and the Parkmate series of non-metallic thermoplastic units. Midwest has the unit for your unique application!

Loop-Feed System

Transformer

Radial-Feed System

Transformer

Figure 551-46(c)

Rugged Durability- All-In-One construction for factory assured terminations- Rolled edge door for cord protection- Heavy (16 gauge) galvanized zinc-coated steel - with highest quality electrodeposition finish - resists corrosion and fading- Welded flange NEMA 3R construction for lasting service in outdoor installations

User Safety- Listed by Underwriters Laboratories- Padlock provision can prevent unauthorized entry- Dead front construction prevents accidental contact with live parts- In-Use Cover allows cords to exit, while maintaining NEMA 3R Integrity

Installation Ease- All components are factory wired and assembled, reducing installation time- Power outlet door has stay-open position for user convenience- All terminals accept copper or aluminum wire - Wide range of receptacle configurations - Broad range of concentric knock-outs to accommodate wiring needs- All units with 12-2 Cu/Al equipment ground lug

Posts- Recreational vehicle park equipment available factory assembled on a padmount or earth-burial post for underground services- Factory wired from loop-feed lugs located in the post to receptacles reducing installation time- Loop-feed lugs have twin 2-250 MCM terminals per phase Cu/Al- Rolled edge post bottoms to protect service cable - Post door removable for installation ease

Features and Benefits

Page 3: RV Park Equipment - Cesco.comRV Park Equipment SURFACE - UNMETERED 3 U055C010 (Fig. M) 20 5-20R2GFI 2020 S P A C E (2) 5-20R2GFI U011C010 (Fig. C) 5-20R2 U010G (Fig. B) 20 GFI U040G

SURFACE - UNMETEREDRV Park Equipment

3

U055C010 (Fig. M)

20

5-20R2GFI

20 20

SPACE

(2) 5-20R2GFI

U011C010 (Fig. C)

5-20R2

U010G (Fig. B)

20GFI

U040G (Fig. G)

GFI

GFI

30GFI

20GFI

�����

BR32U 5-20R2

U040GTL (Fig. H)

R32U 5-20R2GFI

30 20

�����

U041C010 (Fig. I)

R32U 5-20R2GFI

30 20

�����

U041CTL010 (Fig. J)

20 20

SPACE

(2) 5-20R2GFI

UO11CTL010 (Fig. D)

20 20

SPACE

(2) 5-20R2

U011G (Fig. E)

20 20

SPACE

(2) 5-20R2

30GFI

20GFI

�����

R32U 5-20R2

U010C010 (Fig. A)

Wiring Diagrams

Fig. MODEL NUMBER

LUG TYPE RECEPTACLES CIRCUIT PROTECTION

AMP VOLTS WIRE RANGE

CABINET SIZE

HUB OPENING

LOAD & NEUTRAL BAR

UNIT WT.

STD.PKG.

A U010C010 standard 5-20R2GFI CB120 20 120 B 6x9 yes N/A 7 4B U010G standard 5-20R2GFI GFI120 20 120 B 6x9 yes N/A 7 4

C U011C010 standard (2) 5-20R2GFI(2) CB120

SPACE CB120 70 120/240 P 6x14 yes LC33N7 10 4

D U011CTL010 loop feed (2) 5-20R2GFI(2) CB120

SPACE CB120 100 120/240 W 9x17 yes LC33N1T 14 1

E U011G standard (2) 5-20R2(2) GFI120

SPACE CB120 70 120/240 P 6x14 yes LC33N7 10 4

F U011GTL loop feed (2) 5-20R2(2) GFI120

SPACE CB120 100 120/240 W 9x17 yes LC33N1T 14 1

G U040G standardR32U

5-20R2

GFI130 GFI120

SPACE CB120 70 120/240 P 6x14 yes LC33N7 10 4

H U040GTL loop feedBR32U 5-20R2

GFI130 GFI120

SPACE CB120 100 120/240 W 9x17 yes LC33N1T 14 1

I U041C010 standardR32U

5-20R2GFI

CB130 CB120

SPACE CB120 70 120/240 P 6x14 yes LC33N7 10 4

J U041CTL010 loop feedBR32U

5-20R2GFI

CB130 CB120

SPACE CB120 100 120/240 W 9x17 yes LC33N1T 14 1

K U041G standardR32U

5-20R2

CB130 GFI120

SPACE CB120 70 120/240 P 6x14 yes LC33N7 10 4

L U041GTL loop feedBR32U 5-20R2

CB130 GFI120

SPACE CB120 100 120/240 W 9x17 yes LC33N1T 14 1

M U055C010 standard14-50R

5-20R2GFICB250 CB120 70 120/240 O 6x14 yes LC33N7 10 4

30 20

�����GFI

R32U 5-20R2

U041G (Fig. K)

30 20

�����GFI

BR32U 5-20R2

U041GTL (Fig. L)

U011GTL (Fig. F)

14-50R

2050

5-20R2GFI

Page 4: RV Park Equipment - Cesco.comRV Park Equipment SURFACE - UNMETERED 3 U055C010 (Fig. M) 20 5-20R2GFI 2020 S P A C E (2) 5-20R2GFI U011C010 (Fig. C) 5-20R2 U010G (Fig. B) 20 GFI U040G

SURFACE - UNMETEREDRV Park Equipment

4

Wiring Diagrams

U355g (Fig. G)

20GFI

30 20GFI

BR32U (2) 5-20R2

U412G (Fig. H)

3030 20

(2) R32U 5-20R2GFI

U611CTL010 (Fig. I)

3030 20GFI

(2) BR32U 5-20R2

U611GTL (Fig. J)

50 20GFI

14-50R 5-20R2GFI

U055G (Fig. A) U075CTL010 (Fig. B)

SPACE

30 2050

14-50R R32U 5-20R2

UO75GTL (Fig. C)

20 20

SPACE

50

14-50R (2) 5-20R2GFI

U076C010 (Fig. D)

14-50R R32U 5-20R2GFI

SPACE

30 2050 � �� � � �20

SPACE

(2) R32U (2) 5-20R2GFI

U131CTL010 (Fig. E)

20

SPACE

SPACE

50

14-50R 5-20R2GFI

U355C010 (Fig. F)

20GFI

SPACE

SPACE

50

14-50R 5-20R2

Lighted

A U055G standard14-50R

5-20R2GFICB250 GFI120 70 120/240 P 6x14 yes LC33N7 10 4

B U075CTL010 loop feed

14-50R BR32U

5-20R2GFI

CB250, CB130 CB120

SPACE CB120 100 120/240 W 9x17 yes LC55N1T 16 1

C U075GTL loop feed

14-50R BR32U 5-20R2

CB250, CB130 GFI120

SPACE CB120 100 120/240 W 9x17 yes LC55N1T 16 1

D U076C010 standard14-50R

(2) 5-20R2GFI

CB250 (2) CB120

SPACE CB120 100 120/240 U 9x17 yes LC55NT 16 1

E U131CTL010 loop feed(2) 5-20R2GFI

(2) BR32U

(2) CB120 (2) CB130

SPACE CB120 100 120/240 U 14x21 yes LC55NT1 28 1

F U355C010 standard14-50R

5-20R2GFI

CB250 CB120

SPACE CB120 100 120/240 U 9x17 yes LC55N1 16 1

G U355G standard14-50R 5-20R2

CB250 GFI120

SPACE CB2100 100 120/240 U 9x17 yes LC55N1 15 1

H U412G standardBR32U

(2) 5-20R2CB130

(2) GFI120 70 120/240 U 9x17 yes LC33N1 16 1

I U611CTL010 loop feed(2)BR32U 5-20R2GFI

(2) CB130 CB120 80 120/240 W 9x17 yes LC33N1T 16 1

J U611GTL loop feed(2) BR32U

5-20R2(2) CB130

GFI120 80 120/240 W 9x17 yes LC33N1T 15 1

K U775C010 standard

(2) 14-50R BR32U

5-20R2GFI

(2) CB250T CB130

CB120T 100 120/240 W 9x17 yes N/A 15 1

L U041CTLL10 loop feedBR32U

5-20R2GFICB130 CB120 100 120/240 W 9X17 no LC33N1T 14 1

M U075CTLL10 loop feed

BR54U BR32U

5-20R2GFI

CB250, CB130 CB120 SPACE 100 120/240 W 9x17 no LC55N1T 16 1

3020

50

R32U

(2) 14-50R 5-20R2GFI

U775C010 (Fig. K) U041CTLL10 (Fig. L)

BR32U 5-20R2GFI

�����

30 20

14-50R BR32U 5-20R2GFI

30 2050

U075CTLL10 (Fig. M)

Fig. MODEL NUMBER

LUG TYPE RECEPTACLES CIRCUIT PROTECTION

AMP VOLTS WIRE RANGE

CABINET SIZE

HUB OPENING

LOAD & NEUTRAL BAR

UNIT WT.

STD.PKG.

GFI

Page 5: RV Park Equipment - Cesco.comRV Park Equipment SURFACE - UNMETERED 3 U055C010 (Fig. M) 20 5-20R2GFI 2020 S P A C E (2) 5-20R2GFI U011C010 (Fig. C) 5-20R2 U010G (Fig. B) 20 GFI U040G

SURFACE - METEREDRV Park Equipment

MODEL NUMBER

RECEPTACLES CIRCUIT PROTECTION

AMP VOLTS WIRE RANGE

CABINET SIZE

HUB OPENING

LOAD & NEUTRAL BAR

UNIT WT.

STD.PKG.

RING TYPE RINGLESS

A M004C0105-20R2GFI (2) 14-50R

(2) CB250 CB120 100 120/240 AA 9x30 yes LC55N1 26 1

B M011C010 R011C010(2) CB120

SPACE CB120(2) CB120

SPACE CB120 100 120/240 AA 9x30 yes LC33N1 25 1

C M011G R011G(2) GFI120

SPACE CB120(2) GFI120

SPACE CB120 100 120/240 AA 9x17 yes LC33N1 21 1

D M041C010

CB130 CB120

SPACE CB120

CB130 CB120

SPACE CB120 100 120/240 AA 9x30 yes LC33N1 24 1

E M041G R041GBR32U 5-20R2

CB130 GFI120

SPACE CB120 100 120/240 AA 9x30 yes LC33N1 25 1

F M055C010 R055C01014-50R

5-20R2GFICB250 DB120 70 120/240 AA 9x30 yes LC33N1 25 1

G M055G R055G14-50R 5-20R2

CB250 GFI120 70 120/240 AA 9x30 yes LC33N1 25 1

H M075C010

14-50R BR32U

5-20R2GFI

CB250, CB130 GFI120

SPACE CB120 100 120/240 AA 9x30 yes LC55N1 25 1

M004C010 (Fig. A)

20 20

SPACE

(2) 5-20R2GFI

M011C010 (Fig. B)R011C010

M011G (Fig. C)R011G

20 20

SPACE

(2) 5-20R2

M041C010 (Fig. D)

M041G (Fig. E)R041G

30 20

�����GFI

R32U 5-20R2

R32U 5-20R2GFI

30 20

�����

Wiring Diagrams

14-50R

2050

5-20R2GFI

M055C010 (Fig. F)R055C010

M055G (Fig. G)R055G

50 20GFI

14-50R 5-20R2GFI

M075C010 (Fig. H)

2050 50

(2) 14-50R 5-20R2GFI

5

14-50R R32U 5-20R2GFI

30 2050

SPACE

GFI

Page 6: RV Park Equipment - Cesco.comRV Park Equipment SURFACE - UNMETERED 3 U055C010 (Fig. M) 20 5-20R2GFI 2020 S P A C E (2) 5-20R2GFI U011C010 (Fig. C) 5-20R2 U010G (Fig. B) 20 GFI U040G

20

SPACE

SPACE

50

14-50R 5-20R2GFI

M355C010 (Fig. C) M355G (Fig. D)R355G

20GFI

SPACE

SPACE

50

14-50R 5-20R2

M041C010U (Fig. E)

20

SPACE

SPACE

50

14-50R 5-20R2GFI

M355C010U (Fig. H)

BR32U 5-20R2GFI

30 20

�����

M055C010U (Fig. F)R055C010U

14-50R

2050

5-20R2GFI

M075C010U (Fig. G)

14-50R BR32U 5-20R2GFI

30 2050

M076C010 (Fig. B)R076C010

20 20

SPACE

50

14-50R (2) 5-20R2GFI

M075G (Fig. A)

30 20GFI

50�

14-50R BR32U 5-20R2

�����

SPACE

SURFACE - METEREDRV Park EquipmentWiring Diagrams

Bottom Feed

FigMODEL

NUMBERRECEPTACLES CIRCUIT

PROTECTION AMP VOLTS WIRE

RANGECABINET

SIZEHUB

OPENINGLOAD & NEUTRAL

BARUNIT WT.

STD.PKG.

RING TYPE RINGLESS

A M075G

14-50R BR32R 5-20R2\

CB250, CB130 GFI120

SPACE CB120 100 120/240 AA 9x30 yes LC55N1 25 1

B M076C010 R076C01014-50R

(2) 5-20R2GFI

CB250 (2) CB120

SPACE CB120 90 120/240 AA 9x30 yes LC55N1 26 1

C M355C01014-50R

5-20R2GFI

CB250, CB120 (2) SPACE

CB120 100 120/240 AA 9x30 yes LC55N1 25 1

D M355G R355G14-50R 5-20R2

CB250 GFI120

(2) SPACE CB2100 100 120/240 AA 9x30 yes LC55N1 25 1

E M041C010UBR32U

5-20R2GFICB130, CB120 SPACE CB120 100 120/240 2 9x30U yes LC33N1 25 1

F M055C010U R055C010U14-50R

5-20R2GFICB250 CB120 70 120/240 AA 9x30U yes LC33N1 25 1

G M075C010U

14-50R BR32U

5-20R2GFI

CB250, CB130 CB120

SPACE CB120 100 120/240 2 9x30U yes LC55N1 25 1

H M355C010U14-50R

5-20R2GFICB250, CB120

(2) SPACE CB120 100 120/240 2 9x30U yes LC55N1 25 1

6

Page 7: RV Park Equipment - Cesco.comRV Park Equipment SURFACE - UNMETERED 3 U055C010 (Fig. M) 20 5-20R2GFI 2020 S P A C E (2) 5-20R2GFI U011C010 (Fig. C) 5-20R2 U010G (Fig. B) 20 GFI U040G

PEDESTAL - UNMETEREDRV Park Equipment

Fig.

MODEL NUMBER

RECEPTACLES CIRCUIT PROTECTION

AMP VOLTS WIRE RANGE

CABINET SIZE

HUB OPENING

LOAD & NEUTRAL BAR

UNIT WT.

STD.PKG.

A U004CP6010(2) 14-50R 5-20R2GFI

(2) CB250 CB120 100 120/240 T2 9PT no LC55N1 47 1

B U011CP6010 (2) 5-20R2GFI(2) CB120

SPACE CB120 70 120/240 T2 9PT no LC33N7 32 1

C U011GP6 (2) 5-20R2(2) GFI120

SPACE CB120 70 120/240 T2 9PT no LC33N7 32 1

D U040GP6R32U

5-20R2

GFI130 GFI120

SPACE CB120 70 120/240 T2 9PT no LC33N7 32 1

E U041CP6010R32U

5-20R2GFI

CB130 CB120

SPACE CB120 70 120/240 T2 9PT no LC33N7 32 1

F U041GP6R32U

5-20R2

CB130 GFI120

SPACE CB120 70 120/240 T2 9PT no LC33N7 32 1

G U042GP6R32U

5-20R2GFI130 MAIN

CB130, CB120 30 120/240 T2 9PT no LC33N7 32 1

H U055CP601014-50R

5-20R2GFI CB250, CB120 70 120/240 T2 9PT no LC33N7 32 1

I U075CP6010

14-50R BR32U

5-20R2GFI

CB250, CB130 CB120

SPACE CG120 100 120/240 T2 9PT no LC55N1 47 1

7

U004CP6010 (Fig. A)

50

(2) 14-50R 5-20R2GFI

20 5050

POST

U011CP6010 (Fig. B)

(2) 5-20R2GFI

20 20

SPACE

POST POST

U011GP6 (Fig. C)

POST

20 20

SPACE

(2) 5-20R2

U040GP6 (Fig. D)

POST

30GFI

20GFI

�����

R32U 5-20R2

U041CP6010 (Fig. E)

R32U 5-20R2GFI

30 20

�����

U041GP6 (Fig. F)

POST

30 20

�����GFI

R32U 5-20R2

U042GP6 (Fig. G)

POST

3030GFI

20

main

R32U 5-20R2

U055CP6010 (Fig. H)

POST

2050

14-50R 5-20R2GFI

U075CP6010 (Fig. I)

14-50R R32U 5-20R2GFI

POST

Wiring Diagrams

30 2050

�����

GFI

GFI

Page 8: RV Park Equipment - Cesco.comRV Park Equipment SURFACE - UNMETERED 3 U055C010 (Fig. M) 20 5-20R2GFI 2020 S P A C E (2) 5-20R2GFI U011C010 (Fig. C) 5-20R2 U010G (Fig. B) 20 GFI U040G

PEDESTAL - UNMETEREDRV Park Equipment

Fig.

MODEL NUMBER

RECEPTACLES CIRCUIT PROTECTION

AMP VOLTS WIRE RANGE

CABINET SIZE

HUB OPENING

LOAD & NEUTRAL BAR

UNIT WT.

STD.PKG.

A

U075CP6031 (Factory Installed

TV/TELE)

14-50R BR32U

5-20R2GFI

CB250, CB130 CB120

SPACE CG120 100 120/240 T2 9PT no LC55N1 47 1

B U075CP6010D*

14-50R BR32U 5-20R2

CB250, CB130 GFI120

SPACE CB120 100 120/240 T2 9PT no LC55N1 47 1

C U075GP6

14-50R BR32U 5-20R2

(2) CB130, (2) CB120

SPACE CB120 100 120/240 T2 9PT no LC55N1 47 1

D U131CP6010(2) BR32U

(2) 5-20R2GFI

(2) CB130, (2) CB120

SPACE CB120 100 120/240 T2 9PT no LC55N1 47 1

E U355GP614-50R 5-20R2

CB250, GFI120 (2) SPACE CB120 100 120/240 T2 9PT no LC55N1 47 1

F U412CP6010BR32U

(2) 5-20R2GFICB130

(2) CB120 70 120/240 T2 9PT no LC33N1 47 1

G U412GP6BR32U

(2) 5-20R2CB130

(2) GFI120 70 120/240 T2 9PT no LC33N1 51 1

H U611CP6010(2) BR32U 5-20R2GFI

(2) CBI130 CB120 80 120/240 T2 9PT no LC33N1 47 1

I U775CP6010

(2) 14-50R BR32U

5-20R2GFI

(2) CB250T CB130

CB120T 125 120/240 T2 9PT no N/A 97 1

U075CP6031 (Fig. A)

14-50R BR32U 5-20R2GFI

30 2050

U075CP6010D (Fig. B)

14-50R BR32U 5-20R2GFI

POSTPOST POST POST

POST

U075GP6 (Fig. C)

14-50R BR32U 5-20R2

U131CP6010 (Fig. D)

� �

SPACE

� � � �20

(2) BR32U (2) 5-20R2GFI

U355GP6 (Fig. E)

POST

20GFI

SPACE

SPACE

50

14-50R 5-20R2

U412CP6010 (Fig. F)

2030 20

BR32U (2) 5-20R2GFI

U412GP6 (Fig. G)

POST

20GFI

30 20GFI

BR32U (2) 5-20R2

U611CP6010 (Fig. H)

POST

3030 20

(2) BR32U 5-20R2GFI

U775CP6010 (Fig. I)

POST

3020

50

R32U

(2) 14-50R 5-20R2GFI

Wiring Diagram

*Post depth dimension is non-standard (4-3/8”)

SPACE

30 20GFI

50�

SPACE

30 2050

SPACE

8

Page 9: RV Park Equipment - Cesco.comRV Park Equipment SURFACE - UNMETERED 3 U055C010 (Fig. M) 20 5-20R2GFI 2020 S P A C E (2) 5-20R2GFI U011C010 (Fig. C) 5-20R2 U010G (Fig. B) 20 GFI U040G

PEDESTAL - UNMETEREDRV Park Equipment

A U011GP4 (2) 5-20R2(2) GFI120

SPACE CB120 70 120/240 T2 9PT no LC33N7 32 1

B U040GP4 R32U

5-20R2

GFI130 GFI120

SPACE CB120 70 120/240 T2 9PT no LC33N7 32 1

C U041CP4010 R32U

5-20R2GFI

CB130 CB120

SPACE CB120 70 120/240 T2 9PT no LC33N7 32 1

D U041GP4 R32U

5-20R2

CB130 GFI120

SPACE CB120 70 120/240 T2 9PT no LC33N7 32 1

E U075CP4010

14-50R BR32U

5-20R2GFI

CB250, CB130 CB120

SPACE CG120 100 120/240 T2 9PT no LC55N1 47 1

F U075GP4

14-50R BR32U 5-20R2

(2) CB130, (2) CB120

SPACE CB120 100 120/240 T2 9PT no LC55N1 47 1

G U611CP4010 (2) BR32U 5-20R2GFI

(2) CBI130 CB120 80 120/240 T2 9PT no LC33N1 47 1

H U775CP4010

(2) 14-50R BR32U

5-20R2GFI

(2) CB250T CB130

CB120T 125 120/240 T2 9PT no N/A 97 1

PAD MOUNT

U611CP4010 (Fig. G)

PAD MOUNT

3030 20

(2) BR32U 5-20R2GFI

U775CP4010 (Fig. H)

PAD MOUNT

3020

50

R32U

(2) 14-50R 5-20R2GFI

U011GP4 (Fig. A)

20 20

SPACE

(2) 5-20R2

U040GP4 (Fig. B)

30GFI

20GFI

�����

BR32U 5-20R2

U041CP4010 (Fig. C)

BR32U 5-20R2GFI

30 20

�����

U041GP4 (Fig. D)

30 20

�����GFI

BR32U 5-20R2

U075CP4010 (Fig. E)

14-50R BR32U 5-20R2GFI

U075GP4 (Fig. F)

14-50R BR32U 5-20R2

PAD MOUNTPAD MOUNTPAD MOUNTPAD MOUNT

PAD MOUNTPAD MOUNT

Wiring Diagrams

9

30 2050

�����

30 20GFI

50�

�����

Page 10: RV Park Equipment - Cesco.comRV Park Equipment SURFACE - UNMETERED 3 U055C010 (Fig. M) 20 5-20R2GFI 2020 S P A C E (2) 5-20R2GFI U011C010 (Fig. C) 5-20R2 U010G (Fig. B) 20 GFI U040G

PEDESTAL - UNMETEREDRV Park Equipment

A U004CB6010(2) 14-50R 5-20R2GFI

(2) CB250 CB120 100 120/240 S 9PT no LC55N1 62 1

B U011GB6 (2) 5-20R2(2) GFI120

SPACE CB120 70 120/240 T2 6PT no LC33N7 47 1

C U041CB6010R32U

5-20R2GFI

CB130 CB120

SPACE CB120 70 120/240 T2 6PT no LC33N7 47 1

D U041GB6R32U

5-20R2

CB130 GFI120

SPACE CB120 70 120/240 T2 6PT no N/A 47 1

E U042GB6R32U

5-20R2GFI120 MAIN

(2) CB120 30 120 T2 6PT no LC33N7 47 1

F U055GB614-50R 5-20R2

CB250 GFI120 70 120/240 T2 6PT no LC33N7 47 1

G U075CB6010

14-50R BR32U

5-20R2GFI

CB250, CB130 CB120

SPACE CB120 100 120/240 S 9PT no LC55N1 62 1

H

U075CB6031 (Factory Installed

TV/TELE)

14-50R BR32U

5-20R2GFI

CB250, CB130 CB120

SPACE CB120 100 120/240 S 9PT no LC55N1 62 1

I U075GB6

14-50R BR32U 5-20R2

CB250, CB130 GFI120

SPACE CB120 100 120/240 S 9PT no LC55N1 62 1

J U611CB6010(2) BR32U 5-20R2GFI

(2) CB130 CB120 80 120/240 T2 9PT no LC33N1 62 1

Fig.

MODEL NUMBER

RECEPTACLES CIRCUIT PROTECTION

AMP VOLTS WIRE RANGE

CABINET SIZE

HUB OPENING

LOAD & NEUTRAL BAR

UNIT WT.

STD.PKG.

U004CB6010 (Fig. A)

(2) 14-50R 5-20R2GFI

2050 50 2050 50

U011GB6 (Fig. B)

20 20

SPACE

(2) 5-20R2

20 20

SPACE

U041CB6010 (Fig. C)

R32U 5-20R2GFI

30 20

�����

30 20

�����

U041GB6 (Fig. D)

30 20

�����GFI

R32U 5-20R2

30 20

�����GFI

U042GB6 (Fig. E)

3030GFI

20

main

R32U 5-20R2

3030GFI

20

main

U055GB6 (Fig. F)

50 20GFI

14-50R 5-20R2GFI

50 20GFI

U075CB6010 (Fig. G)

14-50RBR32U5-20R2GFI

U075CB6031 (Fig. H)

14-50RBR32U5-20R2GFI

U075GB6 (Fig. I)

14-50RBR32U5-20R2

U611CB6010 (Fig. J)

3030 20

(2) BR32U 5-20R2GFI

3030 20

POST POST POST

Wiring Diagrams

Back to Back

POST POST

POST POST POST POST POST

30 2050

SPACE

30 2050

SPACE

30 20GFI

50�

SPACE

30 2050

SPACE

30 2050

SPACE

30 20GFI

50�

SPACE

10

Page 11: RV Park Equipment - Cesco.comRV Park Equipment SURFACE - UNMETERED 3 U055C010 (Fig. M) 20 5-20R2GFI 2020 S P A C E (2) 5-20R2GFI U011C010 (Fig. C) 5-20R2 U010G (Fig. B) 20 GFI U040G

PEDESTAL - UNMETEREDRV Park Equipment

Lighted

U011GB4 (Fig. A)

(2) 5-20R2

U041GB4 (Fig. B)

R32U 5-20R2

U075CB4010 (Fig. C)

14-50RR32U5-20R2GFI

U611CB4010 (Fig. D)

(2) R32U 5-20R2GFI

3030 20 3030 20

PADMOUNT

PADMOUNT

30 20

�����GFI

30 20

�����GFI

PADMOUNT

20 20

SPACE

20 20

SPACE

PADMOUNT

30 20

�����

30 20

�����

POST

R32U 5-20R2GFI

U041CB6L10 (Fig. E)

POST

U041GP6L (Fig. G)

R32U 5-20R2

POST

30 20

�����GFI

U041CP6L10 (Fig. F)

R32U 5-20R2GFI

30 20

�����

POST

U075CB6L10 (Fig. H)

30 2050

�����

30 2050

�����

POST

30 2050

�����

30 2050

�����

30 2050

�����

POST

30 2050

�����

BR54UBR32U5-20R2GFI

U075CP6L10 (Fig. I)

BR54UBR32U5-20R2GFI

U075GP6L (Fig. J)

BR54UBR32U5-20R2

Fig.

MODEL NUMBER

RECEPTACLES CIRCUIT PROTECTION

AMP VOLTS WIRE RANGE

CABINET SIZE

HUB OPENING

LOAD & NEUTRAL BAR

UNIT WT.

STD.PKG.

A U011GB4 (2) 5-20R2(2) GFI120

SPACE CB120 70 120/240 T2 6PT no LC33N7 47 1

B U041GB4 R32U

5-20R2

CB130 GFI120

SPACE CB120 70 120/240 T2 6PT no N/A 47 1

C U075CB4010

14-50R BR32U

5-20R2GFI

CB250, CB130 CB120

SPACE CB120 100 120/240 S 9PT no LC55N1 62 1

D U611CB4010(2) BR32U 5-20R2GFI

(2) CB130 CB120 80 120/240 T2 9PT no LC33N1 62 1

E U041CB6L10R32U

5-20R2GFICB130, CB120 SPACE CB120 100 120/240 T2 6PT no LC33N1 42 1

F U041CP6L10R32U

5-20R2GFICB130, CB120 SPACE CB120 100 120/240 T2 6PT no LC33N1 30 1

G U041GP6LR32U

5-20R2CB130 CB120 SPACE CB120 100 120/240 T2 6PT no LC33N1 30 1

H U075CB6L10

BR54U BR32U

5-20R2GFI

CB250, CB130 GFI120

SPACE CB120 100 120/240 T2 9PT no LC55N1 62 1

I U075CP6L10

BR54U BR32U

5-20R2GFI

CB250, CB130 GFI120

SPACE CB120 100 120/240 T2 9PT no LC55N1 36 1

J U075GP6L

BR54U BR32U 5-20R2

CB250, CB130 GFI120

SPACE CB120 100 120/240 T2 9PT no LC55N1 62 1

Back to BackPAD MOUNT

Wiring Diagram

11

GFI GFI

Page 12: RV Park Equipment - Cesco.comRV Park Equipment SURFACE - UNMETERED 3 U055C010 (Fig. M) 20 5-20R2GFI 2020 S P A C E (2) 5-20R2GFI U011C010 (Fig. C) 5-20R2 U010G (Fig. B) 20 GFI U040G

PEDESTAL - UNMETEREDRV Park Equipment

A U041CB4L10R32U

5-20R2GFICB130, CB120 SPACE CB120 100 120/240 T2 6PT no LC33N1 42 1

B U041CP4L10R32U

5-20R2GFICB130, CB120 SPACE CB120 100 120/240 T2 6PT no LC33N1 30 1

C UO41GP4LR32U

5-20R2CB130 CB120 SPACE CB120 100 120/240 T2 6PT no LC33N1 30 1

D UO75CB4L10

BR54U BR32U

5-20R2GFI

CB250, CB130 GFI120

SPACE CB120 100 120/240 T2 9PT no LC55N1 62 1

E U075CP4L10

BR54U BR32U

5-20R2GFI

CB250, CB130 GFI120

SPACE CB120 100 120/240 T2 9PT no LC55N1 36 1

F UO75GP4L

BR54U BR32U 5-20R2

CB250, CB130 GFI120

SPACE CB120 100 120/240 T2 9PT no LC55N1 62 1

LightedPAD MOUNT

30 20

�����

30 20

�����

R32U 5-20R2GFI

U041CB4L10 (Fig. A) U041CP4L10 (Fig. B)

R32U 5-20R2GFI

30 20

�����

U041GP4L (Fig. C)

R32U 5-20R2

30 20

�����GFI

U075CB4L10 (Fig. D)

30 2050

�����

30 2050

�����

BR54UBR32U5-20R2GFI

30 2050

�����

U075CP4L10 (Fig. E)

BR54UBR32U5-20R2GFI

30 2050

�����

U075GP4L (Fig. F)

BR54UBR32U5-20R2

PAD MOUNT PAD

MOUNT PAD MOUNT

PAD MOUNT PAD

MOUNTPAD MOUNT

Wiring Diagrams

12

GFI

Page 13: RV Park Equipment - Cesco.comRV Park Equipment SURFACE - UNMETERED 3 U055C010 (Fig. M) 20 5-20R2GFI 2020 S P A C E (2) 5-20R2GFI U011C010 (Fig. C) 5-20R2 U010G (Fig. B) 20 GFI U040G

PEDESTAL - METEREDRV Park Equipment

Fig. MODEL NUMBER

RECEPTACLES CIRCUIT PROTECTION

AMP VOLTS WIRE RANGE

CABINET SIZE

HUB OPENING

LOAD & NEUTRAL BAR

UNIT WT.

STD.PKG.

RING TYPE RINGLESS

A M004CP6010(2) 14-50R 5-20R2GFI

(2) CB250 CB120 100 120/240 T2 9PT no LC88X1 48 1

B M041CP6010 R041CP6010BR21U

5-20R2GFI

CB130 CB120

SPACE CB120 100 120/240 T2 9PT no LC33N1 53 1

C M041GP6 R041GP6BR32U 5-20R2

CB130 GFI120

SPACE CB120 100 120/240 T2 9PT no LC33N1 59 1

D M055GP614-50R 5-20R2

CB250 GFI120 70 120/240 T2 9PT no LC33N1 59 1

E M075CP6010 R075CP6010

14-50R BR32U

5-20R2GFI

CB250, CB130 CB120

SPACE CB120 100 120/240 T2 9PT no LC55N1 59 1

F

M075CP6031 (Factory Installed

TV/TELE)

R075CP6031 (Factory Installed

TV/TELE)

14-50R BR32U

5-20R2GFI

CB250, CB130 CB120

SPACE CB120 100 120/240 T2 9PT no LC55N1 59 1

G M075GP6 R075GP6

14-50R BR32U 5-20R2

CB250, CB130 GFI120

SPACE CB120 100 120/240 T2 9PT no LC55N1 59 1

H M355CP6010 R355CP601014-50R

5-20R2GFI

CB250 CB120

(2) SPACE 100 120/240 T2 9PT yes LC55N1 59 1

2050 50

(2) 14-50R 5-20R2GFI

M004CP6010 (Fig. A) M041CP6010 (Fig. B)R041CP6010

BR32U 5-20R2GFI

30 20

�����

M041GP6 (Fig. C)R041GP6

30 20

�����GFI

BR32U 5-20R2

M055GP6 (Fig. D)

50 20GFI

14-50R 5-20R2GFI

POST POST POST POST

M075CP6010 (Fig. E)R075CP6010

14-50R BR32U 5-20R2GFI

30 2050

SPACE

M075CP6031 (Fig. F)R075CP6031

30 2050

SPACE

14-50R BR32U 5-20R2GFI

M075GP6 (Fig. G)R075GP6

14-50R BR32U 5-20R2

30 20GFI

50�

SPACE

M355CP6010 (Fig. H)R355CP6010

20

SPACE

SPACE

50

14-50R 5-20R2GFI

POST POST POST POST

Wiring Diagrams

13

Page 14: RV Park Equipment - Cesco.comRV Park Equipment SURFACE - UNMETERED 3 U055C010 (Fig. M) 20 5-20R2GFI 2020 S P A C E (2) 5-20R2GFI U011C010 (Fig. C) 5-20R2 U010G (Fig. B) 20 GFI U040G

PEDESTAL - METEREDRV Park Equipment

PAD MOUNT

M355GP6 (Fig. A)R355GP6

20GFI

SPACE

SPACE

50

14-50R 5-20R2

M655GP6 (Fig. C)

20 GFI

SPACESPACE

SPACE

SPACE

SPACE

SPACE

SPACE

SPACE

SPACE

50

14-50R 5-20R2

20GFI

SPACE

SPACE

50

M355GP6028 (Fig. B)

14-50R 5-20R2

M775CP6010 (Fig. D)

3020

50

R32U

(2) 14-50R 5-20R2GFI

POST POST POST POST

M041CP4010 (Fig. E)

2050 50

(2) 14-50R 5-20R2GFI

M041GP4 (Fig. F)

30 20

�����GFI

R32U 5-20R2

M075CP4010 (Fig. G)

14-50R R32U 5-20R2GFI

30 2050

SPACE

M075CP4031 (Fig. H)

14-50R R32U 5-20R2GFI

30 2050

SPACE

M075GP4 (Fig. I)

30 20GFI

50�

SPACE

14-50R R32U 5-20R2

M355GP4 (Fig. J)

20GFI

SPACE

SPACE

50

14-50R 5-20R2

PADMOUNT

PADMOUNT

PADMOUNT

PADMOUNT

PADMOUNT

PADMOUNT

A M355GP6 R355GP614-50R 5-20R2

CB250 GFI120

SPACE CB120 100 120/240 T2 9PT no LC55N1 59 1

BM355GP6028(9” or 14” post) R655GP6

14-50R 5-20R2

CB250 GFI120

SPACE CB2100 100 120/240 T2 9PT no LC55N1 59 1

C M655GP614-50R 5-20R2

CB250, GF120 SPACE CB2200B SPACE (5) CB120

200A. MAX 200 120/240 T2 14PT no LC1212PC 89 1

D M775CP6010

(2) 14-50R BR32U

5-20R2GFI

(2) CB250T CB130

CB120T 125 120/240 T2 9PT no 59 1

E M041CP4010(2) 14-50R 5-20R2GFI

(2) CB250 CB120 100 120/240 T2 9PT no LC88X1 48 1

F M041GP4BR32U 5-20R2

CB130 GFI120

SPACE CB120 100 120/240 T2 9PT no LC33N1 59 1

G M075CP4010

14-50R BR32U

5-20R2GFI

CB250, CB130 CB120

SPACE CB120 100 120/240 T2 9PT no LC55N1 59 1

H

M075CP4031 (Factory Installed

TV/TELE)

14-50R BR32U

5-20R2GFI

CB250, CB130 CB120

SPACE CB120 100 120/240 T2 9PT no LC55N1 59 1

I M075GP4

14-50R BR32U 5-20R2

CB250, CB130 GFI120

SPACE CB120 100 120/240 T2 9PT no LC55N1 59 1

J M355GP414-50R 5-20R2

CB250 GFI120

SPACE CB120 100 120/240 T2 9PT no LC55N1 59 1

Fig. MODEL NUMBER

RECEPTACLES CIRCUIT PROTECTION

AMP VOLTS WIRE RANGE

CABINET SIZE

HUB OPENING

LOAD & NEUTRAL BAR

UNIT WT.

STD.PKG.

RING TYPE RINGLESS

Wiring Diagrams

14

Page 15: RV Park Equipment - Cesco.comRV Park Equipment SURFACE - UNMETERED 3 U055C010 (Fig. M) 20 5-20R2GFI 2020 S P A C E (2) 5-20R2GFI U011C010 (Fig. C) 5-20R2 U010G (Fig. B) 20 GFI U040G

PEDESTAL - METEREDRV Park Equipment

Back to Back

M041CB6010 (Fig. A)

30 20

�����

30 20

�����

BR32U 5-20R2GFI

M041GB6 (Fig. B)R041GB6

30 20

�����GFI

30 20

�����GFI

R32U 5-20R2

M075CB6010 (Fig. C)R075CB6010

30 2050

SPACE

30 2050

SPACE

14-50R BR32U 5-20R2GFI

M075CB4010 (Fig. D)

30 2050

SPACE

30 2050

SPACE

14-50R R32U 5-20R2GFI

M075GB6 (Fig. E)R075GB6

30 20GFI

50�

SPACE

30 20GFI

50�

SPACE

14-50R BR32U 5-20R2

M355GB6 (Fig. F)

20GFI

SPACE

SPACE

50

14-50R 5-20R2

M655GB6 (Fig. G)

20 GFI

SPACESPACE

SPACE

SPACE

SPACE

SPACE

SPACE

SPACE

SPACE

50

20 GFI

SPACESPACE

SPACE

SPACE

SPACE

SPACE

SPACE

SPACE

SPACE

50

14-50R 5-20R2

M775CB6010 (Fig. H)

3020

50

R32U

3020

50

R32U

(2) 14-50R 5-20R2GFI

POST POST POST

POST POST POST POST

PAD MOUNT

A M041CB6010BR32U

5-20R2GFICB130, CB120 SPACE CB120 100 120/240 S 9PT no LC33N1 82 1

B M041GB6 R041GB6BR32U 5-20R2

CB130, GFI120 SPACE CB120 100 120/240 S 9PT no LC33N1 82 1

C M075CB6010 R075CB6010

14-50R BR32U

5-20R2GFI

CB250, CB130 CB120

SPACE CB120 100 120/240 S 9PT no LC55N1 82 1

D M075CB4010

14-50R BR32U

5-20R2GFI

CB250, CB130 CB120

SPACE CB120 100 120/240 S 9PT no LC55N1 82 1

E M075GB6 R075GB6

14-50R BR32U 5-20R2

CB250, CB130 GFI120

SPACE CB120 100 120/240 S 9PT no LC55N1 82 1

F M355GB614-50R 5-20R2

CB250 GFI120

(2) SPACE CB2100 100 120/240 S 9PT no LC55N1 82 1

G M655GB614-50R 5-20R2

CB250 GFI120

(9) SPACE CB120 200 120/240 S 14PT noLC1212PC N1200A4 80 1

H M775CB6010

(2) 14-50R BR32U

5-20R2GFI

(2) CB250T CB130

CB120T 125 120/240 S 9PT no 82 1

Fig. MODEL NUMBER

RECEPTACLES CIRCUIT PROTECTION

AMP VOLTS WIRE RANGE

CABINET SIZE

HUB OPENING

LOAD & NEUTRAL BAR

UNIT WT.

STD.PKG.

RING TYPE RINGLESS

Wiring Diagrams

15

20GFI

SPACE

SPACE

50

Page 16: RV Park Equipment - Cesco.comRV Park Equipment SURFACE - UNMETERED 3 U055C010 (Fig. M) 20 5-20R2GFI 2020 S P A C E (2) 5-20R2GFI U011C010 (Fig. C) 5-20R2 U010G (Fig. B) 20 GFI U040G

PEDESTAL - METEREDRV Park Equipment

Fig. MODEL NUMBER

RECEPTACLES CIRCUIT PROTECTION

AMP VOLTS WIRE RANGE

CABINET SIZE

HUB OPENING

LOAD & NEUTRAL BAR

UNIT WT.

STD.PKG.

RING TYPE RINGLESS

A M041CP6L10

BR32U 5-20R2GFI

SPACE

CB130 CB120 SPACE 100 120/240 T2 9PT yes LC33N1 50 1

B M075CB6L10

14-50R BR32U

5-20R2GFI

CB250, CB130 CB120

SPACE CB120 100 120/240 T2 9PT yes LC55N1 59 1

C

M075CB6L31 (Factory Installed

TV/TELE)

14-50R BR32U

5-20R2GFI

CB250, CB130 CB120

SPACE CB120 100 120/240 T2 9PT yes LC55N1 59 1

D M075CP6L10

14-50R BR32U

5-20R2GFI

CB250, CB130 CB120

SPACE CB120 100 120/240 T2 9PT yes LC55N1 59 1

E

M075CP6L31 (Factory Installed

TV/TELE)

14-50R BR32U

5-20R2GFI

CB250, CB130 CB120

SPACE CB120 100 120/240 T2 9PT yes LC55N1 59 1

F M041CP4L10

BR32U 5-20R2GFI

SPACE

CB130 CB120 SPACE 100 120/240 T2 9PT yes LC33N1 50 1

G M075CB4L10

14-50R BR32U

5-20R2GFI

CB250, CB130 CB120

SPACE CB120 100 120/240 T2 9PT yes LC55N1 59

H M075CP4L10

14-50R BR32U

5-20R2GFI

CB250, CB130 CB120

SPACE CB120 100 120/240 T2 9PT yes LC55N1 59 1

1

Lighted

Lighted, PAD MOUNT

M041CP6L10 (Fig. A)

30 20

�����

POST

R32U 5-20R2GFI

M075CB6L10 (Fig. B)

14-50R R32U 5-20R2GFI

30 2050

SPACE

30 2050

SPACE

POST

M075CB6L31 (Fig. C)

30 2050

SPACE

30 2050

SPACE

POST

14-50R R32U 5-20R2GFI

M075CP6L10 (Fig. D)

30 2050

SPACE

POST

14-50R R32U 5-20R2GFI

M075CP6L31 (Fig. E)

30 2050

SPACE

14-50R R32U 5-20R2GFI

M041CP4L10 (Fig. F)

30 20

�����

PADMOUNT

PADMOUNT

PADMOUNT

M075CB4L10 (Fig. G)

R32U 5-20R2GFI

POST

30 2050

SPACE

30 2050

SPACE

14-50R R32U 5-20R2GFI

M075CP4L10 (Fig. H)

30 2050

SPACE

14-50R R32U 5-20R2GFI

Wiring Diagrams

16

Page 17: RV Park Equipment - Cesco.comRV Park Equipment SURFACE - UNMETERED 3 U055C010 (Fig. M) 20 5-20R2GFI 2020 S P A C E (2) 5-20R2GFI U011C010 (Fig. C) 5-20R2 U010G (Fig. B) 20 GFI U040G

PARKRANGER NON-METALLIC RV POWER PEDESTAL

17

ALL THE AMENITIES OF HOME- Power, running water, cable TV and telephone access- Multiple options available to fulfill individual needs- Emphasis on convenience and safety- Connections grouped behind weather resistant cover for easy access and security- Lighting options provide clear view of service panel for night time connection

AESTHETICS and DESIGN FLEXIBILITY- Flip-top receptacles and other external components have been eliminated- Clean, crisp lines- Controlled lighting system for accent lighting- Custom finishes- Single or double-sided - Individual site metering to recover electrical costs

INSTALLATION, UPGRADING and MAINTENANCE ADVANTAGES- Factory assembled and wired to minimize on-site installation time and expense- Advance shipping of base sections available to facilitate rough wiring and plumbing- Easy to change or add service options with an upgrade kits- Long-term durability - Molded from GE engineered VALOX plastics- Reduces corrosion problems - Infrequent maintenance

FEATURES- Unitized Service Panel to accept electrical components, telephone, cable TV and lighting options- 100 to 200 amps for use with 120/240 volt, 1 phase, 3 W plus ground- Ambient Compensated Thermal Magnetic Circuit Breaker- Weather Resistant with VALOX thermoplastic enclosure- Corrosion Resistant internal components- Prismatic Lens with lighting options to effectively eliminate glare and create maximum illumination- Dress Panel on reverse side of all single service pedestals- Oversize Access Panel for easy installation, upgrading and quick meter reading- Base Module with loop feed terminal bar

Parkranger is a new, non-metallic power pedestal that combines all the favorite features of the old pedestals with the advanced technology and advantages of a non-metallic pedestal.

The Next Generation of Outdoor Luxury

Page 18: RV Park Equipment - Cesco.comRV Park Equipment SURFACE - UNMETERED 3 U055C010 (Fig. M) 20 5-20R2GFI 2020 S P A C E (2) 5-20R2GFI U011C010 (Fig. C) 5-20R2 U010G (Fig. B) 20 GFI U040G

PARKRANGER TECHNICAL INFORMATION

Example: Model Number VWKJHCQW

Receptacles Model Type Option Codes Color

NEMA Circuit Code Receptacles Breaker AMPS VOLTS H 5-20R2 CB120 20 125 I 5-20R2GFI GFI120 20 125 J R32U CB130 30 125 K 14-50R CB250 50 125/250 Z None None --- ----

AAAUAWCP ACASCMCS CO BY

O = optional tan W = standard white

Paint Options

Side 2 Options

(where applicable)

VW KJH CQ _____ _____ WSide 2

Receptacle (where applicable)

Side 1 Options

Side 1 Receptacle

Model Type

VW

Other configurations available. Contact manufacturer.

Receptacle Configuration No Options

7 watt light & photo-cell

7 watt light, photo-cell & 1-TV/phone

Metered w/ 7 watt light, photo-cell, 1-TV/phone

30A/20A VWJZHAAW VWJZHAUW VWJZHCQW VWJZHCSW

50A/30/20A VWKJHAAW VWKJHAUW VWKJHCQW VWKJHCSW**Double sided availabe by adding side 2 receptacles and options shown above

MOST COMMON MODELS - Single Sided**

Wiring Diagrams

VWJZHCQW

3020 � � � � �

� � � � �

7 watt light

photo-cell(1)-TV/phone

5-20R2R32U

3020 � � � � �

� � � � �

5-20R2R32U

VWJZHAAW VWJZHAUW VWJZHCSW

3020 � � � � �

� � � � �

7 watt light

photo-cell

5-20R2R32U

3020 � � � � �

� � � � �

7 watt light

photo-cell(1)-TV/phone

digital meter

5-20R2R32U

VWKJHCSW

7 watt light

photo-cell(1)-TV/phone

digital meter

3020

��

GFI

5-20R2R32U 14-50R

7 watt light

photo-cell(1)-TV/phone

3020

��

GFI

5-20R2R32U 14-50R

VWKJHCQW

7 watt light

photo-cell

3020

��

GFI

5-20R2R32U 14-50R

VWKJHAUW

3020

��

GFI

5-20R2R32U 14-50R

VWKJHAAW18

Page 19: RV Park Equipment - Cesco.comRV Park Equipment SURFACE - UNMETERED 3 U055C010 (Fig. M) 20 5-20R2GFI 2020 S P A C E (2) 5-20R2GFI U011C010 (Fig. C) 5-20R2 U010G (Fig. B) 20 GFI U040G

13.1 16.1

41.7

7.0

14.7

13.6

INDIVIDUAL ACCESSORY CHOICESMODEL DESCRIPTIONVLIGHT 7 Watt fluorescent lightUH12AL Aluminum shroudVAMBER Amber lens coverVAPE Photo-electric sensorVKTELTV1 Tele/TV connection kitVKTELTV2 Tele/TV connection kitULUG3 4th Position lug for 3-phase loop feed #6-350VKDOOR New style door, unmeteredVKDOORM New style door, meteredUHH One pair cord & hose storage rackUBFP Backflow preventerUWATER34 3/4" Hose bibVMASTER1S 125V Electric meter kit-singleVMASTER2S 125V Electric Mmeter kit-dualVMASTER1D 125/250V Electric meter kit-singleVMASTER2D 125/250V Electric meter kit-dual

PARKRANGER OPTION INFORMATION

19

OPTION CODE DESCRIPTIONAA No OptionsAU 7W Light and Photo-cellAW 7W Light, Photo-cell and MeteredCQ 1 TV/Telephone, 7W Light and Photo-cellAC Metered OnlyAS 7W Light and MeteredCM 1 TV/Telephone and 7W LightCS 1 TV/Telephone, 7W Light, Photo-cell and MeteredCO 1 TV/Telephone, 7W Light and MeteredEK 2 TV/Telephone, 7W Light and Metered

MOST COMMON OPTION PACKAGES*

*Other configurations available. Contact Manufacturer.

Page 20: RV Park Equipment - Cesco.comRV Park Equipment SURFACE - UNMETERED 3 U055C010 (Fig. M) 20 5-20R2GFI 2020 S P A C E (2) 5-20R2GFI U011C010 (Fig. C) 5-20R2 U010G (Fig. B) 20 GFI U040G

ELECTRONIC METER WITH COUNTER

FLUORESCENT LIGHT

CABLE TV JACK TELEPHONE JACK

DIRECT BURIAL OR PAD MOUNT INSTALLATION

VALOX THERMOPLASTIC

UP TO 3 RECEPTACLES AVAILABLE

LOOP FEED LUG

R.V. POWER CENTERPARKMATE

Parkmate TV Power Centers combine appear-ance and functionality. Now, campground owners can select an attractive power center that combines all the features RVers request.

- Excellent for surface mount and post applications- Wide array of accessories: light, photoelectric sensor, telephone, cable T.V. connections and electric metering- Injection molded from VALOX engineered thermoplasitc resin- Lightweight, impact and corrosion resistant- Long, maintenance free service- Rugged, convenient and attractive- Manufactured in the quality tradition of Midwest Electric products, Inc.

Features- Listed by Underwriters Laboratories- Service Entrance rated and Listed by Underwriters Laboratories- VALOX thermoplastic enclosure and internal components are corrosion resistant- Factory wired power receptacles are available in 20 amp, 30 amp, or 50 amp configurations protected by thermal magnetic circuit breakers. Ground fault breakers are also available- Hinged cover closes over plugs and cords, maintaining a safe weather tight enclosure- Easy to wire terminal lugs accept up to 1/0 Cu/Al cable- Post features 250 KCMIL loop-feed lugs- Optional 7 watt fluorescent light illuminates receptacles for easy night time plug-in, while providing security lighting and easy identification of power center location. Light circuit is protected by a 20 amp circuit breaker. Light cover molded of LEXAN polycarbonate- Photoelectric sensor automatically turns light on and off- Telephone and cable TV jack accessory kits mount easily in power center giving your installation a neat and uncluttered appearance. Telephone jacks are PH6596 corrosion resistant outlets. Cable TV jacks are suitable for type RG-59 coax cable- Electrical rating of 100 amp max, 120/240 volt, 10-3 wire with ground- Hinged cover has a positive latch with padlocking provisions- Post dimensions 62”H (38 above grade) x 6-1/2”W x 3-1/4”D- Optional loop feed lug kit (ULOOP) available for Parkmate not on a post- Parkmate, post, and water shroud are tan in color- Standard 200A/350KCMIL lugs installed in pedestal models- Amp rating - 200 Amp on back-to-back; 100 Amp on single

20

HEAD

(100 AMP MAX)

TERMINALASSEMBLY

Page 21: RV Park Equipment - Cesco.comRV Park Equipment SURFACE - UNMETERED 3 U055C010 (Fig. M) 20 5-20R2GFI 2020 S P A C E (2) 5-20R2GFI U011C010 (Fig. C) 5-20R2 U010G (Fig. B) 20 GFI U040G

Example: Model Number VPKJHCQT

T = Standard Tan W = Optional White

Receptacles Model Type Option Codes Color

NEMA Circuit Code Receptacles Breaker AMPS VOLTS H 5-20R2 CB120 20 125 I 5-20R2GFI GFI120 20 125 J R32U CB130 30 125 K 14-50R CB250 50 125/250 Z None None --- ----

AAAUAWCP ACASCMCS CO BY

Paint Options

Side 2 Options

(where applicable)

VP KJH CQ _____ _____ TSide 2

Receptacle (where applicable)

Side 1 Options

Side 1 Receptacle

Model Type

Other configurations available. Contact manufacturer.

VKVLVMVNVOVPVQVRVSVT

PARKMATE TECHNICAL INFORMATION

Parkmate Model

Receptacle Configuration No Options 7 watt light

7 watt light & photo-cell

7 watt light photo-cell & 1-TV/Phone Metered Only

Metered w/ 7 watt light, photo-cell, 1-TV/Phone

20A/20A ZHHAAT ZHHAQT ZHHAUT HHHCQT ZHHACT ZHHCST30A/20A JZHAAT JZHAQT JZHAUT JZHCQT JZHACT JZHCST50A/20A KZHAAT KZHAQT KZHAUT KZHCQT KZHACT KZHCST30A/30A/20A JJHAAT JJHAQT JJHAUT JJHCQT JJHACT JJHCST50A/30/20A KJHAAT KJHAQT KJHAUT KJHCQT KJHACT KJHCST

Choose specific model

MOST COMMON MODELS*

*To complete model number add Model Type followed by Option code (following page) desired

VKVLVMVNVOVPVQVRVSVT

ParkmateParkmate for Post (Replacement Head ONLY)Parkmate, single head, stainless post, pad mountParkmate, single head, stainless post, burialParkmate, single head, galvanized post, pad mount Parkmate, single head, galvanized post, burialParkmate, back to back head, stainless post, pad mountParkmate, back to back head, stainless post, burialParkmate, back to back head, galvanized post, pad mountParkmate, back to back head, galvanized post, burial

MODEL TYPE POST TYPE # HEADS1111112222

21

Page 22: RV Park Equipment - Cesco.comRV Park Equipment SURFACE - UNMETERED 3 U055C010 (Fig. M) 20 5-20R2GFI 2020 S P A C E (2) 5-20R2GFI U011C010 (Fig. C) 5-20R2 U010G (Fig. B) 20 GFI U040G

photo-cell photo-cell photo-cell

photo-cell photo-cell photo-cell

JZHCQT

3020 � � � � �

� � � � �

7 watt light

(1)-TV/phone

5-20R2R32U

3020 � � � � �

� � � � �

5-20R2R32U

JZHAAT JZHAUT JZHCST

3020 � � � � �

� � � � �

7 watt light

5-20R2R32U

30

20 � � � � �

� � � � �

7 watt light

(1)-TV/phone

digital meter

5-20R2R32U

KJHCST

7 watt light

(1)-TV/phone

digital meter

3020

��

GFI

5-20R2R32U 14-50R

7 watt light

(1)-TV/phone

3020

��

GFI

5-20R2R32U 14-50R

KJHCQT

7 watt light

3020

��

GFI

5-20R2R32U 14-50R

KJHAUT

30

20

��

GFI

5-20R2R32U 14-50R

KJHAAT

COMMON MODELS: Wiring Diagrams

PARKMATE TECHNICAL INFORMATION

22

MODEL DESCRIPTIONVLIGHT 7 Watt fluorescent lightVLOOP 1/0 Loop lug kitVAMBER Amber lens coverVAPE Photo-electric sensorVKTELTV1 Tele/TV connection kitVKTELTV2 Tele/TV connection kitULUG3 4th Position lug for 3-phase loop feed #6-350UH90ST Stainless water shroudUH90GT Galvanized water shroudUHH One pair cord & hose storage rackUBFP Backflow preventerUWATER34 3/4" Hose bibVMASTER1S 125V Electric meter kit-singleVMASTER2S 125V Electric meter kit-dualVMASTER1D 125/250V Electric meter kit-singleVMASTER2D 125/250V Electric meter kit-dual

INDIVIDUAL ACCESSORY CHOICES

OPTION CODE DESCRIPTIONAA No OptionsAU 7W Light and Photo-cellAW 7W Light, Photo-cell and MeteredCQ 1 TV/Telephone, 7W Light and Photo-cellAC Metered OnlyAS 7W Light and MeteredCM 1 TV/Telephone and 7W LightCS 1 TV/Telephone, 7W Light, Photo-cell and MeteredCO 1 TV/Telephone, 7W Light and MeteredEK 2 TV/Telephone, 7W Light and Metered

MOST COMMON OPTION PACKAGES*

*Other configurations available. Contact Manufacturer.

9 1/4”

13”

5 1/2”

8“

Page 23: RV Park Equipment - Cesco.comRV Park Equipment SURFACE - UNMETERED 3 U055C010 (Fig. M) 20 5-20R2GFI 2020 S P A C E (2) 5-20R2GFI U011C010 (Fig. C) 5-20R2 U010G (Fig. B) 20 GFI U040G

ACCESSORY MODEL DESCRIPTIONPost Extensions* EK126 6PT Post Models

EK129 9PT/9HP Post ModelsMounting Bracket 265A6218G1 For mounting FS box to post of

field installation of TV or telephone jacks

Ground Lug GL6 1/0 Ground LugStabalizer Bases FBEM9 Earth Mount Installation^Bolt-On Hub B07 3/4" Hub size

B10 1" Hub sizeB12 1-1/4" Hub sizeB15 1-1/2" Hub sizeB20 2" Hub sizeB25 2-1/2" Hub sizeB01 Closure PlateS01 Stainless Steel Closure Plate

Circuit Breaker Filler Plates 265A5003P1 1" Metal

265A5003P2 2" Metal265A5003P11 1" Plastic265A5003P12 2" Plastic

Post Stake** MS62

^^

Temporary Adapters (Not UL listed)

RV Park Accessories

*Kit Consists of: (1) Post Extension Bracket, (2) 1/2” Bolts, (2) 1/2” Nuts, (4) 1/2” Flatwashers. Dimensions: 18”L x 6”W or 9”W^Fits all posts

**Kit Consists of: (1) Post Stake Bracket, (2) 1/2” Bolts, (2) 1/2” Nuts, (4) 1/2” Flatwashers. Dimensions: 44”L x 3”W or 1”D

^^Closure Plate is standard with all Midwest products. (Standard Pkg Qty in 10 pcs.)

^^^Receptacles are complete with bracket to base mount in unit.***Bracket not included. Mounts directly on dead front.

23

Receptacles and Angle PlugsNEMA CONFIGURATIONS AMP. VOLTAGE MODEL NUMBER MODEL NUMBER MODEL NUMBER

5-20 R 20 20125 125

5-20R1 SINGLE 5-20R2 DUPLEX

ANSI C73 13-1972 R-32-U 30

AMP. 125 VOLT (Travel Trailer Use Only)

30 125 BR32U R32U*** C32U PR32U

10-30R 30 125/250 BR33 C33 PR33

14-30R 30 125/250 BR34 C34 PR3410-50R 50 125/250 BR53 C53 PR5314-50R 50 125/250 BR54U C54U PR54U18-60R 60 120/208 - C54U14-60R 60 125/250 BR64U C64U PR64U

Receptacles^^^ Angle PlugsReceptacles on Plates

AD 20 30 AD 30 20 AD 50 20

15 AMP., 125 VOLT 30 AMP., 125 VOLT 10 PK. ONLY

30 AMP., 125 VOLT 15 AMP., 125 VOLT 10 Pk. ONLY

50 AMP., 125/250 VOLT 15 AMP., 125 VOLT 10 PK. ONLY

Page 24: RV Park Equipment - Cesco.comRV Park Equipment SURFACE - UNMETERED 3 U055C010 (Fig. M) 20 5-20R2GFI 2020 S P A C E (2) 5-20R2GFI U011C010 (Fig. C) 5-20R2 U010G (Fig. B) 20 GFI U040G

RV Power OutletsCABINET

SIZEENCLOSURE

STYLE A B C KO DETAIL6x9 Fig. A 9-1/8" 7-1/4" 5-3/16" Fig. 1

6x14 Fig. A 14-3/8" 7-1/4" 5-3/16" Fig. 19x17 Fig. A 17-3/8" 9-3/4" 5-3/16" Fig. 29x30 Fig. B 30" 9-3/4" 5-3/16" Fig. 214x21 Fig. A 21-3/8" 14-3/4" 6-7/16" Fig. 33x30U Fig. C 30" 9-3/4" 5-3/16" Fig. 4

Cabinet Dimensions & Knockouts

24

E = 3/4”G = 1/2”, 3/4”, 1”N = 1/2”, 3/4”, 1”, 1-1/4”, 1-1/2”Q = 1”W = 1/2”, 3/4”, 1”, 1-1/4”, 2”

Figure 1 Figure 2 Figure 3 Figure 4

Figure A

A = 1-1/2”, 2”, 2-1/2”B = 1”, 1-1/4”, 1-1/2”C = 1-1/4”, 1-1/2”, 2”D = 3/4”, 1”, 1-1/4”

A

B C

A

B CC

Figure B Figure C

� � �

� ��

� �

��

B B

D � �� �

� �� �

�� BW

A

B

Page 25: RV Park Equipment - Cesco.comRV Park Equipment SURFACE - UNMETERED 3 U055C010 (Fig. M) 20 5-20R2GFI 2020 S P A C E (2) 5-20R2GFI U011C010 (Fig. C) 5-20R2 U010G (Fig. B) 20 GFI U040G

RV Post Dimensions

25

6PT Earth Burial

9PT Earth Burial

14PT Earth Burial

6PT Pad Mount

9PT Pad Mount

ED

A

C

B

A 62"C 19-3/4"D 6-1/2"E 3-1/4"F 18"G 6"

UNMETERED

A

C

D E

F

G

A

C

D E

F

G

B

A 36"C 17-3/4"D 6-1/2"E 3-3/4"

UNMETERED

A 64-1/2" 77-1/2"B - 45-1/4"C 19-1/8" 19-1/8"D 9" 9"E 3-1/2" 3-1/2"F 18" 18"G 6" 6"

UNMETERED METEREDA 41-1/8" 53-1/2"B - 45-1/2"C 19-3/4" 19-1/2"D 9" 9"E 3-1/2" 3-1/2"

UNMETERED METERED

A 86" 86"B - 50"C 49-1/2" 49-1/2"D 9" 9"E 3-1/2" 3-1/2"F 18" 18"G 6" 6"X 21" 38"Y 14" 14"

UNMETERED METERED

D E

G

F

D

HEADPOST

HEA

DPO

ST

HEA

DPOST

HEA

D

XX

YA

B C

KeyA = Post LengthB = Meter Center to GradeC = Terminal Bar to GradeD = Post WidthE = Post DepthF = Grade to Wire OpeningG = Wire Opening

ED

A

C

Page 26: RV Park Equipment - Cesco.comRV Park Equipment SURFACE - UNMETERED 3 U055C010 (Fig. M) 20 5-20R2GFI 2020 S P A C E (2) 5-20R2GFI U011C010 (Fig. C) 5-20R2 U010G (Fig. B) 20 GFI U040G

RV Wire Range Tables

26

TABLE B

Solid Strand Solid StrandLine 14-8 14-6 12-8 12-6Load 14-10 14-10 - -Neutral 12-8 12-6 12-8 12-6Equip. Grnd. 12-8 12-2 12-8 12-2

Connector Copper Aluminum

Small Hole

TABLE UConnector Copper Aluminum

Large Hole

Solid Strand Solid StrandLine 14-8 14-1/0 12-8 12-1/0Load 14-10 14-10 - -Neutral 12-8 12-1/0 10-8 10-1/0Neutral 14-8 14-4 12-8 12-4Equip. Grnd. 12-8 12-2 12-8 12-2

SmallHole

(loop feed)

TABLE W

Solid Strand Solid StrandLine 14-8 12-1/0 12-8 12-1/0Load 14-10 14-10 - -Neutral 12-8 12-1/0 10-8 10-1/0Neutral 14-8 14-4 12-8 12-4Equip. Grnd. 12-8 12-2 12-8 12-2

LargeHole

Copper AluminumConnector

SmallHole

TABLE AA

LargeHole

Solid Strand Solid StrandLine - 6-1/0 - 6-1/0Load 14-10 14-10 - -Neutral 12-8 12-1/0 10-8 10-1/0Neutral 14-8 14-4 12-8 12-4Equip. Grnd. 12-8 12-2 12-8 12-2

ConnectorCopper Aluminum

TABLE AR

Solid Strand Solid StrandLine 14-10 14-10 - -Load 14-10 14-10 - -Neutral - - - -Equip. Grnd. 12-8 12-2 - -

Copper AluminumConnector

TABLE T2Post Line ConnectorsSuitable for Loop Feed

#2-250 KCMIL CU #2-250 KCMIL AL

TABLE P

Solid Strand Solid StrandLine 14-8 14-2 12-8 12-2Load 14-10 14-10 - -Neutral 14-8 14-2 12-8 12-2Neutral 14-8 14-4 12-8 12-4Equip. Grnd. 12-8 12-2 12-8 12-2

ConnectorCopper Aluminum

EndHoleSide Hole

Page 27: RV Park Equipment - Cesco.comRV Park Equipment SURFACE - UNMETERED 3 U055C010 (Fig. M) 20 5-20R2GFI 2020 S P A C E (2) 5-20R2GFI U011C010 (Fig. C) 5-20R2 U010G (Fig. B) 20 GFI U040G

RV Terminal BoxesSingle Phase

Wiring Diagram Model AMP VoltageNumber of

BarsLugs per

Bar Wire Range UL

T1206 60 120/240 3 4 14-4

T1210 100 120/240 3 5 14-1/0

T1220 200 120/240 3 6 (3) 1/0-250 (3) 12-1/0

T1240 400 240 3 5 (2) 1/0-600 (3) 1/0-250

Three Phase

YES

YES

NO

T3210 100 120/240 4 5 14-1/0

T3220 200 120/240 4 6 (3) 1/0-250 (3) 12-1/0

T3610 100 600 4 5 (2) 14-1/0 (3) 1/0-250

T3620 200 600 4 6 (3) 12-1/0 (3) 1/0-250

T3640 400 600 4 5 (2) 1/0-600 (3) 1/0-250

Junction Boxes

CABINET SIZE A B C KO

DETAIL7x10 10" 7-1/4" 4" Fig. 19x17 17-1/2"\ 9-3/4" 3-1/2" Fig. 214x21 21-1/2" 14-1/2" 4-3/4" Fig. 314x26 27-3/4" 14-1/2" 4-3/4" Fig. 4

Enclosure Dimensions

C

A

B

Application Information- Save time and money by using smaller wire from junction boxes in radial feed wiring systems- Loop feed surface or non-pedestal type RV power centers- Convert overhead service to an underground system- Inter-wire multiple buildings in the park or on the farm- Splice boxes for industrial or commercial application

Features and Benefits- Heavy zinc coated steel with electro-deposition paint finish for superior corrosion protection- Rugged NEMA 3R construction protects against both vandalism and the weather- Padlock provision can protect against unauthorized access- Door has stay open position, or removes completely for total acces and easy wiring- A variety of terminal and knockout sizes provides for maximum flexibility- Junction boxes may be mounted to either a wall or a 4x4 post

AA = 1-1/2”, 2”, 2-1/2”B = 1”, 1-1/4”, 1-1/2”C = 1-1/4”, 1-1/2”, 2”D = 3/4”, 1”, 1-1/4”

E = 3/4”G = 1/2”, 3/4”, 1”N = 1/2”, 3/4”, 1”, 1-1/4”,

Figure 1 Figure 2 Figure 3 Figure 4

Model No. AMP Cabinet SizeKnockout

FigureHub Opening (Hub Not Included)

Unit Weight (LBS)

Replacement Terminal Bar

T1206 60 7x10 1 Yes 7 NI60B2T1210 100 9x17 2 Yes 8 NI100B2T1220 200 14x21 3 Yes 16 NI200T1240 400 14x26 4 3" Hub Installed 43 NI1400A1T3210 100 9x17 2 Yes 9 NI100B2T3220 200 14x21 3 Yes 17 NI200T3610 100 9x17 2 Yes 9 NI100B3T3620 200 14x21 3 Yes 18 NI200A5T3640 400 14x26 4 3" Hub Installed 44 NI400A1

� �

� �

� �

��

B B

D

��

AA

D D D D

��

� ��

AA�

27

Page 28: RV Park Equipment - Cesco.comRV Park Equipment SURFACE - UNMETERED 3 U055C010 (Fig. M) 20 5-20R2GFI 2020 S P A C E (2) 5-20R2GFI U011C010 (Fig. C) 5-20R2 U010G (Fig. B) 20 GFI U040G

Rep Offices and Warehouses

35 SEGI Tempe, AZ 85282 Phone: (480) 317-0868 FAX: (480) 317-087536 SEGI N. Salt Lake, UT 84054 Phone: (801) 544-0200 FAX: (801) 292-4164

Billings, MT 59101 Phone: (406) 248-9224 FAX: (406) 245-694337 Electro-Lines, Inc. Syracuse, NY 13208 Phone: (315) 455-5701 FAX: (315) 455-711439 T.F. Farmer Company Greensboro, NC 27415 Phone: (336) 375-1122 FAX: (336) 375-017741 L.W. French, Inc. Glen Allen, VA 23060 Phone: (804) 270-3205 FAX: (804) 270-0885 www.lwfrench.com45 Gemco Sales, Inc. Pittsburgh, PA 15201 Phone: (412) 562-9300 FAX: (412) 562-902846 J.R. Bovyer Electrical Sales of OH Brooklyn Heights, OH 44131 Phone: (330) 650-4013 FAX: (330) 650-258650 Schaeffer Sales, Inc. St. Luois, MO 63045 Phone: (314) 291-9500 FAX: (314) 291-959551 West Coast Sales Auburn, WA 98001 Phone: (253) 833-6434 FAX: (253) 833-6605

53 Curtis H. Stout, Inc. Little Rock, AR 72202 Phone: (501) 374-6694 FAX: (501) 374-139954 Hardcastle Electrical Sales Bowling Green, KY 42104 Phone: (270) 782-1303 FAX: (270) 842-917055 Electrical Products of Oklahoma Oklahoma City, OK 73116 Phone: (405) 842-8371 FAX: (405) 843-1636 Tulsa, OK 74112 Phone: (918) 663-1923 FAX: (918) 663-001556 John Moore & Assocates, Inc. La Vergne, TN 37086 Phone: (615) 287-0500 FAX: (615) 287-0662 www.jmaone.com58 Syn-Tech, Inc. Kenner, LA 70003 Phone: (504) 835-7825 FAX: (504) 835-785359 MWE, Inc. N. Kansas City, MO 64116 Phone: (800) 678-3075 FAX: (816) 842-804761 Schmitz Electrical Sales Elk Grove Village, IL 60007 Phone: (847) 364-3605 FAX: (847) 364-410762 O.T. Hall & Son, Inc. Millersville, MD 21108 Phone: (410) 987-5990 FAX: (410) 987-9691

65 Darmac Agencies Ltd. Burnaby, B.C., CANADA Phone: (604) 520-7121 FAX: (604) 524-216266 Lexco, Inc. Minneapolis, MN 55427 Phone: (763) 542-8242 FAX: (763) 542-9309 www.lesco-inc.com72 Metra Associates Deerfield Beach, FL 33442 Phone: (954) 428-4444 FAX: (954) 428-445575 Theovine, Inc. Lachine, Quebec, CANADA Phone: (514) 637-0050 FAX: (514) 637-463077 David Role & Co. Woburn, MA 01801 Phone: (781) 932-8810 FAX: (781) 932-881583 J.R. Schmidt & Associates Denver, CO 80223 Phone: (866) 779-1313 FAX: (303) 778-761385 Pollart Electrical Sales Company, Inc. Bensalem, PA 19020 Phone: (800) 372-8000 FAX: (215) 245-0773

QUALITY WEATHERPROOF ELECTRICAL EQUIPMENT

Midwest Electric Products, Inc.P.O. Box 910Mankato, MN 56002-0910Phone (507) 345-2505Fax (507) 345-2530www.midwestelectric.com

Key:Representative Headquarters LocationResident SalesmanWarehouseFactory and Headquarters

1

1 Midwest Electric Producs, Inc. Mankato, MN 56001 Phone: (507) 345-2505 FAX: (507) 345-2530 Canada, Hawaii and Puerto Rico7 Bishop & Brogdon Atlanta, GA 30303 Phone: (404) 494- 4333 FAX: (404) 344-36969 Bixler Marketing Group Council Bluffs, IA 51502-0497 Phone: (317) 577-910011 Arther Boyle Company, Inc. Indianapolis, IN 46220 Phone: (317) 577-9100 FAX: (317) 577-916112 Gumersell Cashdan, Inc. Farmingdale, NY 11735 Phone: (631) 752-9440 FAX: (631) 752-944022 G.N. Deperro Company Detriot, MI 48211 Phone: (313) 875-4010-11-12 FAX: (313) 872-554423 Electrorep Sausalito, CA 94965 Phone: (415) 332-4100 FAX: (415) 332-415025 Electra Sales of North Texax, Inc. Phone: (972) 554-8200 FAX: (972) 554-786129 E-Tel Houston, TX 77028 Phone: (713) 678-4460 FAX: (713) 678-437133 Schwind-Berry, Inc. Milwaukee, WI 53202 Phone: (414) 963-1455 FAX: (414) 963-1790 www.schwindberry.com

British Columbia

Ontario

Quebec

SpokaneAuburn

Portland

Sausalito

N. Salt Lake

Phoenix

Billings

Denver

Lubbock

Dallas

HoustonSan Antonio

Metairie

Little Rock

St. Louis

Council Bluffs

Davenport

MankatoMinneapolis

Atlanta

Deerfield Beach

62

12

39

36

1

65

77

5151

35

92383

55

22

59

36

25

50

29

66

58

53

54

1161

33

72

37

7

8546

56

75

41

Millersville

Pittsburg

Greensboro

Syracuse

Boston

Gloucester City

Indianapolis

Bowling Green

KansasCity

Des Moines

Milwaukee Elk GroveVillage Detriot Cleveland

Glen Allen