siemens.com/ruggedcom Brochure Edition 09/2014 RUGGEDCOM Multi-Service Platform Modular Managed Layer 2 / 3 Ethernet Switches, Routers and Security Appliances Answers for industry. © Siemens AG 2014

Transcript of RUGGEDCOM - Multi-Service Platform

Page 1: RUGGEDCOM - Multi-Service Platform

siemens.com/ruggedcom

BrochureEdition 09/2014

RUGGEDCOM Multi-Service PlatformModular Managed Layer 2 / 3 Ethernet Switches, Routers and Security Appliances

Answers for industry.

SIE_RX_BRO_v14_09_2014.indd 1SIE_RX_BRO_v14_09_2014.indd 1 23.09.2014 13:54:4623.09.2014 13:54:46

© Siemens AG 2014

Page 2: RUGGEDCOM - Multi-Service Platform

2 Common features and benefits

ContentsCommon features and benefits 2 – 3

RUGGEDCOM technology 4 – 5

Hardware portfolio 6 – 7

Certification and use cases 8 – 9

Modules 10 – 13

Order options 14 – 15

SIE_RX_BRO_v14_09_2014.indd 2SIE_RX_BRO_v14_09_2014.indd 2 23.09.2014 13:55:1623.09.2014 13:55:16

© Siemens AG 2014

Page 3: RUGGEDCOM - Multi-Service Platform

3Common features and benefits

RUGGEDCOM Multi-Service PlatformsCommon Features and BenefitsLowest total cost of ownership

◾ No hassle upgrades in the field, and the flexibility to adapt to the changing network

Reliability ◾ Utility grade reliability designed in from the very beginning ◾ Current field demonstrated MTBF of 180 years ◾ Designed as per MIL-HDBK-217F reliability guidelines ◾ HALT analysis to enhance product robustness

Carrier grade performance ◾ Layer 2 and layer 3 switching and a rich set of WAN,

serial, switching, routing and management features

Immunity ◾ IEEE 1613 class 2 error-free for substations ◾ IEC 61850-3 performance for substations ◾ Class-B emissions for demanding installations

Suitable for all environments ◾ Certified to several industry standards: power, rail,

ITS, and MIL-STD ◾ Available in various form factors ◾ Best-in-class warranty, support, and services ◾ Expandable with external applications, appliances

and utilities

SIE_RX_BRO_v14_09_2014.indd 3SIE_RX_BRO_v14_09_2014.indd 3 23.09.2014 13:55:2723.09.2014 13:55:27

© Siemens AG 2014

Page 4: RUGGEDCOM - Multi-Service Platform

4 RUGGEDCOM technology

RUGGEDCOM products have been specifically designed and tested to withstand the demands of the mission-critical environments.

Reliable operation in harsh electrical installations ◾ IEC 61850-3 and IEEE 1613 (electric power substations) ◾ IEC 61000-6-2 and IEC 61800-3 (industrial environments) ◾ NEMA TS-2 (traffic control equipment) ◾ EN 50121-4 (railway applications) ◾ EN 50155 (equipment on-board rail vehicles)

Error-free operation in high EMI environments ◾ Zero Packet Loss technology for fiber-based networking

devices ◾ IEEE 1613 class 2 error-free performance under EMI stress ◾ Fiber optic ports supporting both short and long haul fiber

Operation in industrial temperature range ◾ -40°C to +85°C normal operation ◾ Passive cooling – no fans

High availability ◾ Integrated single or redundant power supplies ◾ Universal high-voltage range: 88 – 300 VDC or 85 – 264 VAC ◾ Low voltage DC: 12 VDC (9 – 15 VDC), 24 VDC (10 – 36 VDC)

or 48 VDC (36 – 72 VDC) ◾ Dual power supplies can be powered independently,

from different input voltagesDurable installations

◾ Full metal enclosure ◾ Heavy duty mounting ◾ Industrial terminal blocks for power and I/O connection

The proliferation of IP networking technology from the office to industrial environments, for use in real-time, mission critical, control applications requires a level of immu-nity to electromagnetic interference (EMI) well beyond what is currently delivered by commercial grade networking products. In fact, even the EMI immunity requirements pre-scribed by IEC 61000-6-2 (Generic Standards – Immunity for Industrial Environments) are inadequate for many environments.

One such environment is the electric utility substation, where EMI levels can be significantly higher than those of the generic industrial environment defined in IEC 61000-6-2. In order to address this risk, both the IEC and IEEE have developed and issued new standards addressing EMI immunity requirements for communica-tions networking equipment in electric utility substations.

In response to these requirements, Siemens RUGGEDCOM technology withstands all of the EMI type tests required by IEC 61850-3 without experiencing any communica-tions loss or delays. Products featuring this technology also qualify as IEEE 1613 class 2 error-free devices.

This innovation is known as Zero Packet Loss technology and it is designed to provide the same level of EMI immu-nity, performance relaying, and reliability as protective relaying devices.

RUGGEDCOM technology

Zero Packet LossRugged Rated

SIE_RX_BRO_v14_09_2014.indd 4SIE_RX_BRO_v14_09_2014.indd 4 23.09.2014 13:55:2823.09.2014 13:55:28

© Siemens AG 2014

Page 5: RUGGEDCOM - Multi-Service Platform

5

Electric Power

Transportation

Industrial Automation

Informationbackbone for all industries

RUGGEDCOM technology

IEC 61850 standard for communications in substations is composed of ten parts, which outlines a complete frame-work for substation automation, including EMI (electro-magnetic interference), immunity and environmental requirements (IEC 61850-3) for communications networks in substations.

The EMI immunity requirements of IEC 61850-3 are derived from IEC 61000-6-5 (Immunity for Power Station and Substation Environments), which defines a set of potentially destructive EMI type tests designed to simulate both continuous and transient EMI phenomena in the substation.

This standard has a minimum requirement that the net-working equipment operates without any physical damage, reset or latch-up during the application of a variety of destructive EMI immunity type tests.

IEEE 1613 is an industry standard for communications net-working devices in electric power substations. It specifies ratings, environmental performance and testing require-ments for communications networking devices installed in electric power substations.

Within the standard, two classes of devices are defined, based on the outcome of a specific set of potentially destructive EMI type tests (EMI stress) designed to simu-late EMI phenomena in the substation. These type tests are derived from the same type tests applied to mission critical protective relays (i.e. C37.90.).

Class 1 — these devices are allowed to experience data errors, loss, or delays when exposed to EMI stress.

Class 2 — these devices must provide error-free (i.e. no data errors, delays or loss) operation when exposed to EMI stress.

Neither class of device must experience any permanent damage under EMI stress.

Siemens RUGGEDCOM family qualifies as IEEE 1613 Class 2 error-free devices, putting these products in a class of their own.

IEC 61850 IEEE 1613

SIE_RX_BRO_v14_09_2014.indd 5SIE_RX_BRO_v14_09_2014.indd 5 23.09.2014 13:55:3323.09.2014 13:55:33

© Siemens AG 2014

Page 6: RUGGEDCOM - Multi-Service Platform

6 Hardware portfolio

Common featuresManagement Layer 2 (switching) Layer 3 (routing) SecurityWeb UI QoS MPLS Integrated firewallHTTPS RSTP, eRSTP, MSTP DHCP IPSecSSH SNTP VRRPv2 and VRRPv3 VPNRMON L2TPv2, L2TPv3 PIM SM HTTPSSNMP Port rate limiting OSPF VLANsCLI Link backup BGP SNMPv3Remote Syslog Port mirroring Traffic prioritization Port-based access controlReal-time line traces Broadcast storm filtering WAN interfaces MAC-based port securityUSB mass-storage Cellular interfaces RADIUSSerial console IS-IS Brute Force Attack prevention

Dead peer detection

RUGGEDCOM RX1500 RUGGEDCOM RX1501 RUGGEDCOM RX1510 RUGGEDCOM RX1511 ◾ 2 redundant power modules ◾ 4 slots for line module

◾ 1 power module ◾ 6 slots for line modules

◾ 2 redundant power modules ◾ 4 slots for line modules

◾ 1 power module ◾ 2 slots for line modules

Hardware portfolio

Available pluggable transceiversType Part number Distance Mode/speed Wavelength Connector

SFP

6GK6000-8FE51-0AA0 2 km

100 BaseFX 1310 nm

LC

6GK6000-8FE52-0AA0 20 km6GK6000-8FE53-0AA0 50 km6GK6000-8FE54-0AA0 90 km6GK6000-8FG51-0AA0 500 m 1000 BaseSX 850 nm6GK6000-8FG52-0AA0 10 km

1000 BaseLX 1310 nm6GK6000-8FG53-0AA0 25 km6GK6000-8FG54-0AA0 70 km 1550 nm6GK6000-8FB51-0AA0 10 km

1000 BaseBX

1310 nm TX1490 nm RX6GK6000-8FB51-0AA0 40 km

6GK6000-8FB52-0AA0 10 km 1490 nm TX1310 nm RX6GK6000-8FB52-0AA0 40 km

SFP+6GK6000-8FT51-0AA0 10 km 10 G BaseLR 1310 nm6GK6000-8FT53-0AA0 40 km 10 G BaseER 1550 nm6GK6000-8FT52-0AA0 80 km 10 G BaseZR

SIE_RX_BRO_v14_09_2014.indd 6SIE_RX_BRO_v14_09_2014.indd 6 23.09.2014 13:55:3723.09.2014 13:55:37

© Siemens AG 2014

Page 7: RUGGEDCOM - Multi-Service Platform

7Hardware portfolio

Connectivity

RX15xx RX5000 MX5000Power Screw terminal / plug terminal Screw terminal10 Gbps None SFP+, up to 80 kmGigabit LC, SC, M12 (A, X-coded), RJ45, SFP – up to 70 km LC, SC, RJ45, SFP – up to 25 km LC, micro-D, SFP – up to 25 kmFast Ethernet

LC, SC, ST, MTRJ, RJ45, M12 (D, A, X-coded), SFP – up to 90 km

LC, SC, ST, MTRJ, RJ45, SFP– up to 90 km

LC, ST, micro-D, RJ45– up to 90 km

APE RJ45, USB, DVI

None

10 FL ST – up to 2 kmT1 RJ48 (channelized)E1 RJ48, BNC (channelized)DDS RJ48 (56k master/slave, 64k slave)

Cellular SMA (antennas), 2FF (mini-SIM), GSM, EDGE, HSPA, EVDO (network)

Serial RJ45 (RS232, RS422, RS485)Chassis DB9/RJ45 console, RJ45 managemet, USB DB9 console, RJ45 management, USB

RUGGEDCOM RX1512 RUGGEDCOM RX5000 RUGGEDCOM MX5000 RUGGEDCOM MX5000RE ◾ Internal DC power supply ◾ 2 slots for line modules

◾ 2 redundant power modules ◾ 6 slots for line modules

◾ 2 redundant power modules ◾ 6 slots for line modules ◾ MIL-STD certified

◾ 2 redundant power modules ◾ 6 slots for line modules ◾ Fan control and alarm unit ◾ MIL-STD certified ◾ IP65 enclosure

Use case: electric powerG

_RC

M0_

XX

_000

37

IED

Industrial Ethernet

Power

MU MU IED

IEDIED

IED

Industrial Ethernet Station Bus with IEC 61850

Layer 2 and 3 router and switch with WAN interfaces

Layer 2 and 3 router and switch with WAN interfaces

IEDIED

IED

Industrial Ethernet Process Bus with IEC 61850

IED

C

B

A

SIE_RX_BRO_v14_09_2014.indd 7SIE_RX_BRO_v14_09_2014.indd 7 23.09.2014 13:55:4323.09.2014 13:55:43

© Siemens AG 2014

Page 8: RUGGEDCOM - Multi-Service Platform

8

Use case: traffic management

Certification and use cases

RUGGEDCOM RX1500

RUGGEDCOM RX1501

RUGGEDCOM RX1510

RUGGEDCOM RX1511

RUGGEDCOM RX1512

RUGGEDCOM RX5000

RUGGEDCOM MX5000

Power 2 1 2 1 1 (internal) 2 210 GigE None 2 2Gigabit 8 4 8 4 4 24 24100 TX 24 36 24 12 12 96 48100 FX 24 36 24 12 12 48 48Serial 24 36 24 12 12 48 48APE 2 2 2 2 1

None10FL 12 18 12 6 6T1/E1 4 4 4 4 4DDS 4 4 4 2 2Cellular 8 12 8 4 4

Certification and use cases

Port density

Traffic Management Center

Variable MessageSign

Vehicle Detector

IP Camera

RUGGEDCOMRX5000

RUGGEDCOMRX1510

G_R

CM

0_X

X_0

0005Industrial Ethernet

(Fiber Optic)

Industrial Ethernet (Copper)

SIE_RX_BRO_v14_09_2014.indd 8SIE_RX_BRO_v14_09_2014.indd 8 23.09.2014 13:56:0823.09.2014 13:56:08

© Siemens AG 2014

Page 9: RUGGEDCOM - Multi-Service Platform

9

Use case: railway control

Certification and use cases

Comprehensive certification

Product TUV

UL –

Sie

men

s

FCC

part

15

CISP

R22

KEM

A (IE

C 61

850)

Altit

ude

(40,

000f

t)

Railw

ay

EN50

155

NTS

– EM

I

NTS

– M

WS

DC M

AGNE

T TE

ST –

NAV

AL

CE D

ecla

ratio

n –

Siem

ens

CCC

(Chi

na)

Wai

ver

CCC

(Chi

na)

HS C

odes

RCM

(Aus

tralia

) –

Siem

ens

KCC(

Kore

a)

– Si

emen

s

RUGGEDCOM RX1500 • • • • • • • • •RUGGEDCOM RX1501 • • • • • • • • •RUGGEDCOM RX1510 • • • • • • • • • •RUGGEDCOM RX1511 • • • • • • •RUGGEDCOM RX1512 • • • • • • •RUGGEDCOM RX5000 • • • • • • • • • • • •RUGGEDCOM MX5000RE • • • • • • •

Industrial Ethernet Industrial Ethernet (Fiber Optic)

Industrial Ethernet(over VDSL)

Depot / StationSerial

RailwaySignaling

Passenger Information and Safety

Control Centre

RUGGEDCOM RX5000

RUGGEDCOMRS900L

RUGGEDCOMRS930L

RUGGEDCOMRS400

RUGGEDCOMRX1500

SCALANCE XR324-4M PoE TS

G_R

CM

0_X

X_0

0009

SIE_RX_BRO_v14_09_2014.indd 9SIE_RX_BRO_v14_09_2014.indd 9 23.09.2014 13:56:0923.09.2014 13:56:09

© Siemens AG 2014

Page 10: RUGGEDCOM - Multi-Service Platform

10 Modules

Modules

Hot-swappable RUGGEDCOM RX1500 modules

MTRJ

100FX

2

1

MTRJ

1

13

24

2

3

4

100FX

SC

100FX

TX

2

RX

TX

1

RX

ST

100FX

TX

2

RX

TX

1

RX

LC

100FX

TX2RX

TX1RX

SFP

1000X

TX2RX

TX1RX

SFP

100FX

2

3

4

5

6

1

LC

100FX

TX1RX

TX2RX

TX3RX

TX4RX

13

24

M12

1000T

1

2

M12 BYPASS

1000T

1

2

RJ45

1000T

1

2

ST

10FL

1 2

1

2

3

3

RX

TX

RX

TX

RX

TX

APE

RESET

DDTPWR

USB

ETH

DVI-D

APE

M12

100TX

1

3

2

4

M12 BYPASS

100TX

1

3

2

4

RJ45

SERIAL

2

3

4

5

6

1

DDS

DDS

RX TX

CELL

CELL

ANT1

ANT2

RX DIV1

RX DIV2

CELL

CELL

LINK/ACT

ANT

RX DIV

T1/E1

T1/E1

RX TX12

1

2

T1/E1

T1/E1

RX TX

T1/E1

T1/E1

RX TX1234

1

2

3

4

E1

E1

RX TX1

RX

TX

E1

E1

RX TX12

RX

TX

1

RX

TX

2

85–264VAC, 88–300VDC

FAILSAFE

PM

-/N

+/L

OU

T: 3.3VDC, 50W

IN: 100-240VAC, 50-60H

z, 1.2A 125/250V --- , 1.2A

36–72VDC

FAILSAFE

PM

-

+

OU

T: 3.3V , 50W IN

: 36-72V , 1.8A

15–36VDC

FAILSAFE

PM

-

+

OU

T: 3.3V , 50W IN

: 13-36V , 5.2A

9–15VDC

FAILSAFE

PM

-

+

OU

T: 3.3V , 50W IN

: 13-36V , 5.2A

SIE_RX_BRO_v14_09_2014.indd 10SIE_RX_BRO_v14_09_2014.indd 10 23.09.2014 13:56:1123.09.2014 13:56:11

© Siemens AG 2014

Page 11: RUGGEDCOM - Multi-Service Platform

11Modules

Hot-swappable RUGGEDCOM RX5000 modules

CM

LT/ACO

MGMT

CONSOLE

FAILSAFE

CF-C

ARD

ALARM

USB

CPU

ALARM

SM-8G/L2

1TX

RX

1000X

2TX

RX

Switch

ALARM

SM-8G/L2

1000X

TX

1

RX

TX

2

RX

Switch

ALARM

1

2

SM-8G/L2

1000T

Switch

ALARM

1

2

SM-8G/L2

1000T

Switch

ALARM

TX

1

LM-100FX

RX

TX

2

RX

TX

3

RX

TX

4

RX

TX

5

RX

TX

6

RX

TX

7

RX

TX

8

RX

SC

ALARM

TX1

LM-100FX

RX

TX2RX

TX3RX

TX4RX

TX5RX

TX6RX

TX7RX

TX8RX

LC

ALARM

LM-100TX

21

43

65

87

Micro-D

ALARM

LM-100TX

P1

P3

P5

P7

P2

P4

P6

P8

P9

P11

P13

P15

P10

P12

P14

P16

RJ45

ALARM

LM-SERIAL

1 5

62

3 7

4 8

DB9

ALARM

51

62

73

84

LM-100FX

MTRJ

ALARM

1

LM-1000X

TX

RX

2TX

RX

3TX

RX

4TX

RX

LC

ALARM

1

2

3

4

LM-100FX

MTRJ

ALARM

1

LM-1000X

TX

RX

2

TX

RX

3

TX

RX

4

TX

RX

SC

ALARM

3

4

LM-1000T

1

2

RJ45

ALARM

3

4

LM-1000T

1

2

Micro-D

PM

+/L

-/N

IN: 1

00-2

40VA

C, 5

0-60

Hz,

1.2

A

1

25/2

50V

, 1.2

AO

UT:

12V

DC,

84W

Power

PM

Power

SIE_RX_BRO_v14_09_2014.indd 11SIE_RX_BRO_v14_09_2014.indd 11 23.09.2014 13:56:1323.09.2014 13:56:13

© Siemens AG 2014

Page 12: RUGGEDCOM - Multi-Service Platform

12 Modules

Feature key mapping

Mechanical characteristics

Features required Switching hardware required Feature key to order

L2 Switching, VLAN, QoS, MSTP, RSTP, eRSTP, SNTP, L2TP, Port Rate Limiting, Broadcast Storm Filtering, Port Mirroring, SNMP, RMON, CLI, Web UI, Hot-Swap, USB main storage, Serial

Layer 2 L2SE

All L2SE features, as well as: L3 Switching, DHCP, VRRP, PIM, OSPF, BGP, IS-IS, RIP, T1/E1, Cell, DDS, Traffic Prioritization, Firewall, MPLS, IS-IS, Brute Force Attack prevention

Layer 2 L3SEL2HW

Layer 3 L3SEL3HWAll L3SE features, as well as: IPSec, VPN, dead peer detection

Layer 2 L3SECL2HWLayer 3 L3SECL3HW

RUGGEDCOM RX1500

RUGGEDCOM RX1501

RUGGEDCOM RX1510

RUGGEDCOM RX1511

RUGGEDCOM RX1512

RUGGEDCOM RX5000

RUGGEDCOM MX5000

Ingress Protection IP 40Maximum weight 5 kg 3.5 kg 2.5 kg 16 kgWidth 440 mm (19“) 240 mm 155 mm 115 mm 440 mm (19“)Depth 300 mm 200 mm 220 mmHeight 44 mm (1U) 125 mm (3 U) 176 mm (4U)Maximum Heat Dissipation

65 W 222 BTU/hr

35 W 120 BTU/hr

30 W 102 BTU/hr

110 W 375 BTU/hr

Feature keys are upgradeable by purchasing an upgrade package. Upgrading switching hardware requires replacement of the chassis (RUGGEDCOM RX15xx) or control module (RUGGEDCOM RX5000 / RUGGEDCOM MX5000).

Modules

SIE_RX_BRO_v14_09_2014.indd 12SIE_RX_BRO_v14_09_2014.indd 12 23.09.2014 13:56:1623.09.2014 13:56:16

© Siemens AG 2014

Page 13: RUGGEDCOM - Multi-Service Platform

Modules 13

Utility grade processing platform for critical applications

Integrated applications

Orderable as a line module for the RUGGECOM RX1500 product family

◾ Windows 7 embedded ◾ CheckPoint GAiA ◾ Debian Linux

2 physically separated Gigabit Ethernet interfaces for: ◾ Industrial ◾ IPSec/VPN site links ◾ IDS (requires Services contract) ◾ Secure access (RUGGEDCOM CROSSBOW) ◾ Protocol conversion (RUGGEDCOM ELAN) ◾ Customer applications

RUGGEDCOM APE1402

RUGGEDCOM APE1404

RUGGEDCOM APE1402W7

RUGGEDCOM APE1404W7

RUGGEDCOM APE1404CKP

Front Ethernet Gigabit, RJ45 portBackplane Ethernet Gigabit, internal to RUGGEDCOM RX15xx chassisUSB 2 ports, USB 2.0Processor Intel Atom E660T, 32-bit, 5000 MIPS at 1.3 GHz, 512 KB cache, Intel HT and VT-xDisplay DVI portRAM 2 GB DDR-2 industrial-grade PCB-solderedOperating system Debian Linux Windows 7 embedded CheckPoint GAiASDD (fixed) 8 GB 16 GB 8 GB 16 GB 16 GB

RUGGEDCOM APE line module

Secure Remote AccessRUGGEDCOM CROSSBOW SAC can be installed internally on RUGGEDCOM RX15xx, or on RUGGEDCOM APE. Installation is possible at the time of order or in the field.

Protocol conversionRUGGEDCOM ELAN can be installed on RUGGEDCOM RX15xx or on RUGGEDCOM APE

◾ Performance limits apply to internal RUGGEDCOM ELAN installation

◾ Internal RUGGECOM ELAN installation must be ordered at the same time as the RUGGEDCOM RX1500 unit

◾ RUGGEDCOM ELAN installation in field is not possible without special procedures

Security applianceRUGGEDCOM APE can be ordered with CheckPoint GAiA for existing CheckPoint customers.

RUGGEDCOM APE with Linux can be bundled with RUGGEDCOM Services contracts for:

◾ Physical firewall (Shorewall configuration) ◾ Intrusion Detection Sensor (Snort) and Intrusion

Detection System with rules selection

e

SIE_RX_BRO_v14_09_2014.indd 13SIE_RX_BRO_v14_09_2014.indd 13 23.09.2014 13:56:1623.09.2014 13:56:16

© Siemens AG 2014

Page 14: RUGGEDCOM - Multi-Service Platform

14 Order options

RUGGEDCOM RX15xx order optionsPluggable or screw terminal power modules01 12 VDC (9 – 15 VDC)02 24 VDC (15 – 36 VDC)03 48 VDC (36 – 72 VDC) 04 88 – 300 VDC or 85 – 264 VACFixed power supply (RUGGEDCOM RX1512 only)05 11 – 72 VDC screw terminal blockSwitch hardware06 Layer 2 switch07 Layer 3 switchManufacturing modification08 Standard09 Conformal coatedMounting10 DIN and panel mount kit11 19“ rack mount kitSoftware

12 Layer 2 standard edition

13 Layer 3 standard edition

14 Layer 3 security edition

Application Processing Engine15 1.3 GHz, 2 GB RAM, 8 GB SATA, DVI-D video, 2 x USB, Linux

16 1.3 GHz, 2 GB RAM, 8 GB SATA, DVI-D video, 2 x USB, Windows 7 embedded

17 1.3 GHz, 2 GB RAM, 16 GB SATA, DVI-D video, 2 x USB, Linux

18 1.3 GHz, 2 GB RAM, 16 GB SATA, DVI-D video, 2 x USB, Windows 7 embedded

19 1.3 GHz, 2 GB RAM, 16 GB SATA, DVI-D video, 2 x USB, Checkpoint (Requires existing Checkpoint license)

100 BaseFX modules with 2-port modules

20 2 x 100 FX – multimode, 1300 nm, ST connectors, 2 km

21 2 x 100 FX – multimode, 1300 nm, SC connectors, 2 km

22 2 x 100 FX – multimode, 1300 nm, LC connectors, 2 km

23 2 x 100 FX – multimode, 1300 nm, MTRJ connectors, 2 km

24 2 x 100 FX – singlemode, 1300 nm, ST connectors, 20 km

25 2 x 100 FX – singlemode, 1300 nm, SC connectors, 20 km

26 2 x 100 FX – singlemode, 1300 nm, LC connectors, 20 km

27 2 x 100 FX – singlemode, 1300 nm, SC connectors, 50 km

28 2 x 100 FX – singlemode, 1300 nm, LC connectors, 50 km

29 2 x 100 FX – singlemode, 1300 nm, SC connectors, 90 km

30 2 x 100 FX – singlemode, 1300 nm, LC connectors, 90 km

RUGGEDCOM RX15xx order options10 BaseFL / 100 BaseSX with 3-port modules

31 3 x 10 FL / 100 SX – multimode, 850 nm, ST connectors, 2 km

100 BaseFX with 4-port modules32 4 x 100 FX – multimode, 1300 nm, LC connectors, 2 km

33 4 x 100 FX – multimode, 1300 nm, MTRJ connectors, 2 km

34 4 x 100 FX – singlemode, 1300 nm, LC connectors, 50 km

35 4 x 100 FX – singlemode, 1300 nm, LC connectors, 90 km

36 4 x 100 FX – SFP

Gigabit Ethernet with 2-port modules37 2 x 1000 SX – multimode, 850 nm, LC connectors, 500 m38 2 x 1000 LX – singlemode, 1300 nm, SC connectors, 10 km39 2 x 1000 LX – singlemode, 1300 nm, LC connectors, 10 km40 2 x 1000 LX – singlemode, 1300 nm, SC connectors, 25 km41 2 x 1000 LX – singlemode, 1300 nm, LC connectors, 25 km42 2 x 1000 LX – SFPWAN port options43 1 x T1/E1 RJ48 (channelized/unchannelized)44 2 x T1/E1 RJ48 (channelized/unchannelized)45 4 x T1/E1 RJ48 (channelized/unchannelized)46 1 x E1 75 Ohms BNC (channelized/unchannelized)47 2 x E1 75 Ohms BNC (channelized/unchannelized)48 1 x GSM/EDGE/HSPA49 2 x GSM/EDGE/HSPA50 1 x EVDO rev A Verizon US51 2 x EVDO rev A Verizon US52 2 x GSM/EDGE/HSPA and EVDO rev A Verizon US53 1k DDS RJ48 (56k Master/Slave 64k Slave)M12 copper Ethernet modules54 2 x 10/100/1000 TX – 8-pin, X-coded55 2 x 10/100/1000 TX – 8-pin, X-coded with controlled bypass56 2 x 10/100/1000 TX – 8-pin57 2 x 10/100/1000 TX – 8-pin, A-coded with controlled bypass58 4 x 10/100 TX – 4-pin, D-coded59 4 x 10/100 TX – 4-pin, D-coded with controlled bypass60 4 x 10/100 TX – 8-pin61 4 x 10/100 TX – 8-pin, A-coded with controlled bypassCopper Ethernet modules62 6 x 10/100 TX – RJ4563 2 x 10/100/1000 TX – RJ45Serial line module64 6 x RS232/RS422/RS485 – RJ45

Order options

SIE_RX_BRO_v14_09_2014.indd 14SIE_RX_BRO_v14_09_2014.indd 14 23.09.2014 13:56:3523.09.2014 13:56:35

© Siemens AG 2014

Page 15: RUGGEDCOM - Multi-Service Platform

15Order options

RUGGEDCOM RX5000 and RUGGEDCOM MX5000 order optionsPower modules01 88 – 300 VDC or 85 – 264 VAC screw terminal block on module02 88 – 300 VDC or 85 – 264 VAC terminal block on frontEthernet and power indicators03 Rack front mount, interfaces and LEDs on front04 Rack rear mount, no interfaces/LEDs on front panel05 Rack rear mount, front panel with power terminal blocksManufacturing modifications06 Standard07 Conformal coatedMounting08 Panel mount kit09 19“ Rack mount kitLayer 2 8 gigabit throughput switch modules10 2 x 1000 LX – singlemode, 1310 nm, SC connectors, 10 km11 2 x 1000 LX – singlemode, 1310 nm, LC connectors, 10 km12 2 x 1000 LX – singlemode, 1310 nm, SC connectors, 25 km13 2 x 1000 LX – singlemode, 1310 nm, LC connectors, 25 km14 2 x 1000 LX – SFPLayer 3 8 gigabit throughput switch modules15 2 x 10/100/1000T – RJ4516 2 x 1000 SX – multimode, 850 nm, LC connectors, 500 m17 2 x 1000 LX – singlemode, 1310 nm, SC connectors, 10 km18 2 x 1000 LX – singlemode, 1310 nm, LC connectors, 10 km19 2 x 1000 LX – singlemode, 1310 nm, SC connectors, 25 km20 2 x 1000 LX – singlemode, 1310 nm, LC connectors, 25 km21 2 x 1000 LX – SFPLayer 3 88 gigabit switch module22 2 x 10G SFP+ (empty slot)

Software

26 Layer 2 standard edition

27 Layer 3 standard edition

29 Layer 3 security edition

10/100Base TX with 16-port modules34 16 x 10/100TX – RJ45

RUGGEDCOM RX5000 and RUGGEDCOM MX5000 order options100BaseFX with 8-port modules35 8 x 100 FX – multimode, 1310 nm, ST connectors, 2 km36 8 x 100 FX – multimode, 1310 nm, SC connectors, 2 km37 8 x 100 FX – multimode, 1310 nm, LC connectors, 2 km38 8 x 100 FX – multimode, 1310 nm, MTRJ connectors, 2 km39 8 x 100 FX – singlemode, 1310 nm, ST connectors, 20 km40 8 x 100 FX – singlemode, 1310 nm, SC connectors, 20 km41 8 x 100 FX – singlemode, 1310 nm, LC connectors, 20 km42 8 x 100 FX – singlemode, 1310 nm, SC connectors, 50 km43 8 x 100 FX – singlemode, 1310 nm, LC connectors, 50 km44 8 x 100 FX – singlemode, 1310 nm, SC connectors, 90 km45 8 x 100 FX – singlemode, 1310 nm, LC connectors, 90 km100BaseFX with 4-port modules46 4 x 100 FX – multimode, 1310 nm, ST connectors, 2 km47 4 x 100 FX – multimode, 1310 nm, SC connectors, 2 km48 4 x 100 FX – multimode, 1310 nm, LC connectors, 2 km49 4 x 100 FX – multimode, 1310 nm, MTRJ connectors, 2 km50 4 x 100 FX – singlemode, 1310 nm, ST connectors, 20 km51 4 x 100 FX – singlemode, 1310 nm, SC connectors, 20 km52 4 x 100 FX – singlemode, 1310 nm, LC connectors, 20 km53 4 x 100 FX – singlemode, 1310 nm, SC connectors, 50 km54 4 x 100 FX – singlemode, 1310 nm, LC connectors, 50 km55 4 x 100 FX – singlemode, 1310nm, SC connectors, 90 km56 4 x 100 FX – singlemode, 1310 nm, LC connectors, 90 kmGigabit Ethernet with 4-port modules57 4 x 10/100/1000 TX RJ4558 4 x 1000 SX – multimode, 850 nm, LC connectors, 500 m59 4 x 1000 LX – singlemode, 1310 nm, SC connectors, 10 km60 4 x 1000 LX – singlemode, 1310 nm, LC connectors, 10 km61 4 x 1000 LX – singlemode, 1310 nm, SC connectors, 25 km62 4 x 1000 LX – singlemode, 1310 nm, LC connectors, 25 km63 4 x 1000 LX – SFP blank (no transceivers)Serial line module64 8 x RS232/RS422/RS485 configurable DB9

SIE_RX_BRO_v14_09_2014.indd 15SIE_RX_BRO_v14_09_2014.indd 15 23.09.2014 13:56:3623.09.2014 13:56:36

© Siemens AG 2014

Page 16: RUGGEDCOM - Multi-Service Platform

Security informationSiemens provides products and solutions with industrial security functions that support the secure operation of plants, solutions, machines, equipment and/or networks. They are important components in a holistic industrial security concept. With this in mind, Siemens’ products and solutions undergo continuous development. Siemens recommends strongly that you regularly check for product updates.

For the secure operation of Siemens products and solutions, it is necessary to take suitable preventive action (e.g. cell protection concept) and integrate each component into a holistic, state-of-the-art industrial security concept. Third-party products that may be in use should also be considered. For more information about industrial security, visit http://www.siemens.com/industrialsecurity.

To stay informed about product updates as they occur, sign up for a product-specific newsletter. For more information, visit http://support.automation.siemens.com.

The information provided in this brochure contains merely general descriptions or characteristics of performance which in case of actual use do not always apply as described or which may change as a result of further development of the products. An obligation to provide the respective characteristics shall only exist if expressly agreed in the terms of contract. Availability and technical specifications are subject to change without notice. All product designations may be trademarks or product names of Siemens AG or supplier companies whose use by third parties for their own purposes could violate the rights of the owners.

Subject to change without prior noticeArticle No. 6ZB5531-0AF02-0BA0DR.PN.RG.14.XXBR.95.07 / Dispo 26000BR 1014 2. EB 16 EnPrinted in Germany © Siemens AG 2014

Siemens AGIndustry SectorSensors and CommunicationPostfach 48 4890026 NÜRNBERGGERMANY

www.siemens.com/automation

SIE_RX_BRO_v14_09_2014.indd 16SIE_RX_BRO_v14_09_2014.indd 16 23.09.2014 13:56:3623.09.2014 13:56:36

© Siemens AG 2014