R&S®CMW500 Test & Measurement Data Sheet | 05.00 … · Wideband Radio Communication Tester...

34
Test & Measurement Data Sheet | 05.00 R&S®CMW500 Wideband Radio Communication Tester Specifications

Transcript of R&S®CMW500 Test & Measurement Data Sheet | 05.00 … · Wideband Radio Communication Tester...

Page 1: R&S®CMW500 Test & Measurement Data Sheet | 05.00 … · Wideband Radio Communication Tester Specifications ... WCDMA specifications ... except fnonharmonic = 3900 MHz

Test

& M

easu

rem

ent

Data

She

et |

05.0

0R&S®CMW500Wideband RadioCommunication TesterSpecifications

Titel + Rück_CMW500.indd 1 25.11.2008 18:05:23

Page 2: R&S®CMW500 Test & Measurement Data Sheet | 05.00 … · Wideband Radio Communication Tester Specifications ... WCDMA specifications ... except fnonharmonic = 3900 MHz

2 R&S®CMW500 Wideband Radio Communication Tester Version 05.00, November 2008

CONTENTS General technical specifications ................................................................................................................................... 5

RF generator...........................................................................................................................................................................................5 Modulation source: arbitrary waveform generator (ARB) (R&S®CMW-B110A option)........................................................................7

RF analyzer.............................................................................................................................................................................................7 Power meter ........................................................................................................................................................................................8 Spectrum measurements ....................................................................................................................................................................9

RF Path 2 with RF TRX (R&S®CMW-B570 option) and RF Frontend (BASIC) (R&S®CMW-B590A option) .........................................9 Timebase ..............................................................................................................................................................................................10

Timebase TCXO................................................................................................................................................................................10 Timebase basic OCXO (R&S®CMW-B690A option) .........................................................................................................................10 Timebase highly stable OCXO (R&S®CMW-B690B option)..............................................................................................................10 Reference frequency inputs/outputs..................................................................................................................................................10

GSM specifications – mobile station test ................................................................................................................... 11 GSM RF generator (prerequisite: R&S®CMW-B110A option) ..............................................................................................................11

GSM GEN (R&S®CMW-KG200 option).............................................................................................................................................11 GSM WINIQSIM2 (R&S®CMW-KW200 option).................................................................................................................................11

GSM RF analyzer (R&S®CMW-KM200 option).....................................................................................................................................11 Modulation analysis...........................................................................................................................................................................12 Power versus time measurement......................................................................................................................................................12 Spectrum due to modulation measurement ......................................................................................................................................12 Spectrum due to switching measurement .........................................................................................................................................12

WCDMA specifications – mobile station (UE) test ..................................................................................................... 13 WCDMA RF generator (prerequisite: R&S®CMW-B110A option).........................................................................................................13

WCDMA GEN (R&S®CMW-KG400 option), WCDMA HSPA GEN (R&S®CMW-KG401 option).......................................................13 WCDMA WINIQSIM2 (R&S®CMW-KW400 option), WCDMA HSDPA WINIQSIM2 (R&S®CMW-KW401 option), WCDMA HSUPA WINIQSIM2 (R&S®CMW-KW402 option) ..........................................................................................................................................13

WCDMA RF analyzer (R&S®CMW-KM400 option and R&S®CMW-KM401 option) .............................................................................14 Modulation analysis...........................................................................................................................................................................14 Spectrum measurements ..................................................................................................................................................................15 Power meter ......................................................................................................................................................................................15

GPS specifications........................................................................................................................................................ 16 GPS RF generator (prerequisite: R&S®CMW-B110A option) ...............................................................................................................16

GPS WINIQSIM2 (R&S®CMW-KW620 option) .................................................................................................................................16 DVB specifications........................................................................................................................................................ 16

DVB RF generator (prerequisite: R&S®CMW-B110A option) ...............................................................................................................16 DVB WINIQSIM2 (R&S®CMW-KW630 option)..................................................................................................................................16

TD-SCDMA specifications – mobile station (UE) test ................................................................................................ 17 TD-SCDMA RF generator (prerequisite: R&S®CMW-B110A option)....................................................................................................17

TD-SCDMA WINIQSIM2 (R&S®CMW-KW750 option) and TD-SCDMA ENH. WINIQSIM2 (R&S®CMW-KW751 option)................17 TD-SCDMA RF analyzer (R&S®CMW-KM750 option)..........................................................................................................................17

Page 3: R&S®CMW500 Test & Measurement Data Sheet | 05.00 … · Wideband Radio Communication Tester Specifications ... WCDMA specifications ... except fnonharmonic = 3900 MHz

Version 05.00, November 2008 R&S®CMW500 Wideband Radio Communication Tester 3

Modulation analysis...........................................................................................................................................................................18 Code domain .....................................................................................................................................................................................19 Spectrum measurements ..................................................................................................................................................................19 Power meter ......................................................................................................................................................................................19

CDMA2000® 1xRTT specifications – mobile station test ........................................................................................... 20 CDMA2000® 1xRTT RF generator (prerequisite: R&S®CMW-B110A option).......................................................................................20

CDMA2000® WINIQSIM2 (R&S®CMW-KW800 option).....................................................................................................................20 CDMA2000® RF analyzer (R&S®CMW-KM800 option) ........................................................................................................................20

Modulation analysis...........................................................................................................................................................................21 Code domain .....................................................................................................................................................................................22 Spectrum measurements ..................................................................................................................................................................22 Power meter ......................................................................................................................................................................................22

CDMA2000® 1xEV-DO specifications – access terminal test .................................................................................... 23 CDMA2000® 1xEV-DO RF generator (prerequisite: R&S®CMW-B110A option) ..................................................................................23

1xEV-DO WINIQSIM2 (R&S®CMW-KW880 option)..........................................................................................................................23 CDMA2000® 1xEV-DO RF analyzer (R&S®CMW-KM880 option) ........................................................................................................23

Modulation analysis...........................................................................................................................................................................24 Code domain .....................................................................................................................................................................................25 Spectrum measurements ..................................................................................................................................................................25 Power meter ......................................................................................................................................................................................25

WiMAX® specifications – mobile station test ............................................................................................................. 26 WiMAX® RF generator (prerequisite: R&S®CMW-B110A option) .........................................................................................................26

WiMAX® WINIQSIM2 (R&S®CMW-KW700 option) ...........................................................................................................................26 WiMAX® RF analyzer (R&S®CMW-KM700 option) ...............................................................................................................................26

Power measurement .........................................................................................................................................................................27 Modulation analysis...........................................................................................................................................................................27 Spectrum measurements ..................................................................................................................................................................28

Digital I/Q 1 to 4 (R&S®CMW-B510A option) .............................................................................................................. 29 Digital I/Q interface ...............................................................................................................................................................................29 AUX interface........................................................................................................................................................................................29 Included extras......................................................................................................................................................................................29

General data .................................................................................................................................................................. 30 Ordering information .................................................................................................................................................... 32

Recommended extras for manual operation.........................................................................................................................................33 Recommended extras...........................................................................................................................................................................33

Page 4: R&S®CMW500 Test & Measurement Data Sheet | 05.00 … · Wideband Radio Communication Tester Specifications ... WCDMA specifications ... except fnonharmonic = 3900 MHz

4 R&S®CMW500 Wideband Radio Communication Tester Version 05.00, November 2008

Specifications apply under the following conditions:

Data valid for R&S®CMW500 or R&S®CMW280 unless otherwise stated. Data without tolerance limits is not binding. Based on a 24-month calibration interval unless otherwise stated. 15 minutes warm-up time at ambient temperature, specified environmental conditions met, calibration cycle adhered to, and all internal automatic adjustments performed. "Typical values" are designated with the abbreviation "typ." These values are verified during the final test but are not assured by Rohde & Schwarz. "Nominal values" are design parameters that are not assured by Rohde & Schwarz. These values are verified during product development but are not specifically tested during production. In line with the 3GPP/3GPP2 standard, chip rates are specified in Mcps (million chips per second), whereas bit rates and symbol rates are specified in kbps (thousand bits per second) or ksps (thousand symbols per second). Mcps, kbps, and ksps are not SI units.

During the production process, each instrument is calibrated in line with defined procedures. All measurement results, including measurement uncertainties of the calibration system, have to be within the published specification limits to release the individual instrument. The expanded measurement uncertainties of the calibration system used in the production process are determined with a coverage factor of k = 2 (normally approx. 95 % probability).

CDMA2000® is a registered trademark of the Telecommunications Industry Association (TIA - USA). “WiMAX Forum“ is a registered trademark of the WiMAX Forum. “WiMAX,“ the WiMAX Forum logo, “WiMAX Forum Certified,“ and the WiMAX Forum Certified logo are trademarks of the WiMAX Forum.

Page 5: R&S®CMW500 Test & Measurement Data Sheet | 05.00 … · Wideband Radio Communication Tester Specifications ... WCDMA specifications ... except fnonharmonic = 3900 MHz

Version 05.00, November 2008 R&S®CMW500 Wideband Radio Communication Tester 5

General technical specifications

RF generator Frequency range 70 MHz to 3300 MHz

up to 6000 MHz with R&S®CMW-KB036 option

Frequency resolution 0.1 Hz Frequency uncertainty same as timebase + frequency resolution

Output level range

70 MHz to 100 MHz continuous wave (CW) –130 dBm to –15 dBm peak envelope power (PEP) up to –15 dBm overranging (PEP) up to –10 dBm

100 MHz to 3300 MHz continuous wave (CW) –130 dBm to –5 dBm peak envelope power (PEP) up to –5 dBm overranging (PEP) up to 0 dBm

3300 MHz to 6000 MHz continuous wave (CW) –120 dBm to –15 dBm peak envelope power (PEP) up to –15 dBm overranging (PEP) up to –10 dBm

RF1 COM, RF2 COM

maximum input DC level 0 V DC 70 MHz to 100 MHz

continuous wave (CW) –120 dBm to –2 dBm peak envelope power (PEP) up to –2 dBm overranging (PEP) up to +3 dBm

100 MHz to 3300 MHz continuous wave (CW) –120 dBm to +8 dBm peak envelope power (PEP) up to +8 dBm overranging (PEP) up to +13 dBm

3300 MHz to 6000 MHz continuous wave (CW) –110 dBm to –2 dBm peak envelope power (PEP) up to –2 dBm overranging (PEP) up to +3 dBm

RF1 OUT

maximum input DC level 0 V DC Output level uncertainty in temperature range +20 °C to +35 °C,

no overranging

output level >–120 dBm 70 MHz to 100 MHz <1.2 dB 1 100 MHz to 3300 MHz <0.6 dB 1

RF1 COM, RF2 COM

3300 MHz to 6000 MHz <1.2 dB 1 output level >–110 dBm

70 MHz to 100 MHz <1.6 dB 1 100 MHz to 3300 MHz <0.8 dB 1

RF1 OUT

3300 MHz to 6000 MHz <1.6 dB 1 Output level uncertainty in temperature range +5 °C to +45 °C,

no overranging

output level >–120 dBm 70 MHz to 100 MHz <2.0 dB 1 100 MHz to 3300 MHz <1.0 dB 1

RF1 COM, RF2 COM

3300 MHz to 6000 MHz <2.0 dB 1 output level >–110 dBm

70 MHz to 100 MHz <2.0 dB 1 100 MHz to 3300 MHz <1.0 dB 1

RF1 OUT

3300 MHz to 6000 MHz <2.0 dB 1

1 Valid for a 12-month calibration interval.

Page 6: R&S®CMW500 Test & Measurement Data Sheet | 05.00 … · Wideband Radio Communication Tester Specifications ... WCDMA specifications ... except fnonharmonic = 3900 MHz

6 R&S®CMW500 Wideband Radio Communication Tester Version 05.00, November 2008

Output level linearity with fixed RF output attenuator setting

in temperature range +20 °C to +35 °C, GPRF generator list mode, level range 0 dB to –30 dB

RF1 COM, RF2 COM no overranging <0.2 dB, typ. <0.1 dB

Output level resolution 0.01 dB typical values after 1 h warm-up time, always returning to same level and frequency, no temperature change, insignificant time change

output level ≥–80 dBm <0.01 dB

Output level repeatability

output level <–80 dBm <0.05 dB

VSWR 70 MHz to 3300 MHz <1.2 3300 MHz to 5000 MHz <1.5

RF1 COM, RF2 COM

5000 MHz to 6000 MHz <1.6 70 MHz to 3300 MHz <1.5 3300 MHz to 5000 MHz <1.5

RF1 OUT

5000 MHz to 6000 MHz <1.6

Attenuation of 2nd harmonic RF1 COM, RF2 COM 70 MHz to 6000 MHz, P < –10 dBm >30 dB RF1 OUT 70 MHz to 6000 MHz, P < 0 dBm >30 dB

Attenuation of 3rd harmonic RF1 COM, RF2 COM 70 MHz to 6000 MHz, P < –10 dBm >40 dB RF1 OUT 70 MHz to 6000 MHz, P < 0 dBm >40 dB

>5 kHz offset from carrier, for output level >–40 dBm, for full scale CW signal

400 MHz to 3300 MHz, except fnonharmonic = 3900 MHz – fcarrier, except fnonharmonic = 3900 MHz

>60 dB

3300 MHz to 3600 MHz >25 dB

Attenuation of nonharmonics

3600 MHz to 6000 MHz, except fnonharmonic = 2 × fcarrier – 6400 MHz

>40 dB

Phase noise single sideband, 70 MHz to 3300 MHz Carrier offset ≥1 MHz <–120 dBc, 1 Hz

Phase noise single sideband, 3300 MHz to 6000 MHz Carrier offset ≥1 MHz <–117 dBc, 1 Hz

Signal-to-noise ratio 70 MHz to 3300 MHz RF1 COM, RF2 COM 5 MHz offset from carrier,

for output level >–30 dBm >95 dB, typ. >101 dB, 1 kHz (>125 dB, typ. >131 dB, 1 Hz)

Signal-to-noise ratio 3300 MHz to 6000 MHz RF1 COM, RF2 COM 5 MHz offset from carrier,

for output level >–30 dBm >92 dB, 1 kHz

Page 7: R&S®CMW500 Test & Measurement Data Sheet | 05.00 … · Wideband Radio Communication Tester Specifications ... WCDMA specifications ... except fnonharmonic = 3900 MHz

Version 05.00, November 2008 R&S®CMW500 Wideband Radio Communication Tester 7

Modulation source: arbitrary waveform generator (ARB) (R&S®CMW-B110A option) Memory size 1.024 Gbyte

I 16 bit Q 16 bit

Word length

marker 4 bit to 16 bit Sample length with 4-bit marker up to 227.55 Msample

minimum 400 Hz Sample rate maximum 100 MHz

RF analyzer VSWR

70 MHz to 3300 MHz <1.2 3300 MHz to 5000 MHz <1.5

RF1 COM, RF2 COM

5000 MHz to 6000 MHz <1.6

Inherent spurious response without input signal 70 MHz to 6000 MHz,

except 4000 MHz, 4800 MHz, 5600 MHz, 6000 MHz

<–100 dBm

Spurious response for full scale single tone input signal 70 MHz to 3300 MHz <–55 dB 3300 MHz to 3700 MHz, except fin = 6400 MHz – fselected, except fin = 6400 MHz – 0.5 × fselected

<–40 dB

3700 MHz to 6000 MHz, except fin = 6400 MHz – 0.5 × fselected

<–40 dB

Harmonic response 2nd harmonic

fin = 70 MHz to 1650 MHz, fselected = 140 MHz to 3300 MHz

<–30 dB RF1 COM, RF2 COM

fin = 1650 MHz to 3000 MHz, fselected = 3300 MHz to 6000 MHz

<–30 dB

Harmonic response 3rd harmonic

fin = 70 MHz to 1100 MHz, fselected = 210 MHz to 3300 MHz

<–50 dB RF1 COM, RF2 COM

fin = 1100 MHz to 2000 MHz, fselected = 3300 MHz to 6000 MHz

<–50 dB

Phase noise single sideband, 70 MHz to 3300 MHz Carrier offset ≥1 MHz <–120 dBc, 1 Hz

Phase noise single sideband, 3300 MHz to 6000 MHz Carrier offset ≥1 MHz <–117 dBc, 1 Hz

Trigger Trigger sources BASE: external TRIG A,

BASE: external TRIG B, GPRF: free run, GPRF: IF power, GPRF: BB generator, WCDMA: DCCH TTI trigger, WCDMA: frame trigger, WCDMA: HS-DPCCH trigger, WCDMA: slot trigger, WCDMA: TPC trigger

Page 8: R&S®CMW500 Test & Measurement Data Sheet | 05.00 … · Wideband Radio Communication Tester Specifications ... WCDMA specifications ... except fnonharmonic = 3900 MHz

8 R&S®CMW500 Wideband Radio Communication Tester Version 05.00, November 2008

Power meter 70 MHz to 3300 MHz Frequency range

up to 6000 MHz with R&S®CMW-KB036 option

Frequency resolution 0.1 Hz Resolution bandwidths Gaussian, 1 kHz to 10 MHz, in 1/3/5 steps,

bandpass, 1 kHz to 30 MHz, in 1/3/5 steps, RRC, α = 0.1, 3.84 MHz, RRC, α = 0.22, WCDMA filter, 1.2288 MHz, CDMA filter

Expected nominal power setting range for ADC full scale 70 MHz to 100 MHz –37 dBm to +42 dBm 2 100 MHz to 3300 MHz –47 dBm to +42 dBm 2

RF1 COM, RF2 COM

3300 MHz to 6000 MHz –37 dBm to +42 dBm 2 Level range

70 MHz to 100 MHz continuous power (CW) –74 dBm 3 to +34 dBm peak envelope power (PEP) up to +42 dBm 2

100 MHz to 3300 MHz continuous power (CW) –84 dBm 3 to +34 dBm peak envelope power (PEP) up to +42 dBm 2

3300 MHz to 6000 MHz continuous power (CW) –74 dBm 3 to +34 dBm peak envelope power (PEP) up to +42 dBm 2

RF1 COM, RF2 COM

maximum input DC level 0 V DC Level uncertainty in temperature range +20 °C to +35 °C

70 MHz to 100 MHz <1.0 dB 4 100 MHz to 3300 MHz <0.5 dB 4

RF1 COM, RF2 COM

3300 MHz to 6000 MHz <1.0 dB 4 Level uncertainty in temperature range +5 °C to +45 °C

70 MHz to 100 MHz <1.2 dB 4 100 MHz to 3300 MHz <0.7 dB 4

RF1 COM, RF2 COM

3300 MHz to 6000 MHz <1.2 dB 4 Level linearity with fixed expected nominal power setting

in temperature range +20 °C to +35 °C, level range 0 dB to –40 dB

RF1 COM, RF2 COM <0.3 dB Level resolution 0.01 dB

typical values after 1 h warm-up time, always returning to same level and frequency, no temperature change, insignificant time change

input level ≥–40 dBm <0.01 dB

Level repeatability

input level <–40 dBm <0.03 dB Dynamic range 70 MHz to 3300 MHz, RBW →1 kHz,

with fixed expected nominal power setting >100 dB

Expected nominal power setting for full dynamic range RF1 COM, RF2 COM –8 dBm to +42 dBm 2

Dynamic range 3300 MHz to 6000 MHz, RBW → 1 kHz,

with fixed expected nominal power setting >97 dB

Expected nominal power setting for full dynamic range RF1 COM, RF2 COM +2 dBm to +42 dBm 2

2 The maximum permissible continuous power is +34 dBm due to thermal limits. 3 RBW → 1 kHz. 4 Valid for a 12-month calibration interval.

Page 9: R&S®CMW500 Test & Measurement Data Sheet | 05.00 … · Wideband Radio Communication Tester Specifications ... WCDMA specifications ... except fnonharmonic = 3900 MHz

Version 05.00, November 2008 R&S®CMW500 Wideband Radio Communication Tester 9

Spectrum measurements FFT spectrum analyzer (R&S®CMW-KM010 option)

70 MHz to 3300 MHz Frequency range up to 6000 MHz with R&S®CMW-KB036 option

Frequency span 1.25 MHz, 2.5 MHz, 5 MHz, 10 MHz, 20 MHz, 40 MHz

FFT length 1k, 2k, 4k, 8k, 16k Detector peak, rms Level range see general technical specifications Level uncertainty for centerfrequency and detector → peak see general technical specifications

Dynamic range

70 MHz to 3300 MHz, for FFT length →16k and span → 5 MHz (equivalent to RBW →781 Hz)

>100 dB

Expected nominal power setting for full dynamic range

RF1 COM, RF2 COM –8 dBm to +42 dBm 5 Dynamic range 3300 MHz to 6000 MHz,

for FFT length →16k and span → 5 MHz (equivalent to RBW →781 Hz)

>97 dB

Expected nominal power setting for full dynamic range

RF1 COM, RF2 COM +2 dBm to +42 dBm 5 Inherent spurious response without input signal see general technical specifications

RF Path 2 with RF TRX (R&S®CMW-B570 option) and RF Frontend (BASIC) (R&S®CMW-B590A option) 6 The R&S®CMW-B570 and the R&S®CMW-B590A makes the second RF path (RF Path 2) available on the front of the instrument with three additional RF connectors RF3 COM, RF4 COM and RF3 OUT. RF3 COM equivalent to RF1 COM see general technical specifications RF4 COM equivalent to RF2 COM see general technical specifications RF3 OUT equivalent to RF1 OUT see general technical specifications

5 The maximum permissible continuous power is +34 dBm due to thermal limits. 6 R&S®CMW500 only.

Page 10: R&S®CMW500 Test & Measurement Data Sheet | 05.00 … · Wideband Radio Communication Tester Specifications ... WCDMA specifications ... except fnonharmonic = 3900 MHz

10 R&S®CMW500 Wideband Radio Communication Tester Version 05.00, November 2008

Timebase

Timebase TCXO Max. frequency drift in temperature range +5 °C to +45 °C ±1 × 10–6 Max. aging at +25 °C,

after 14 days of continuous operation ±1 × 10–6/year

Timebase basic OCXO (R&S®CMW-B690A option) Max. frequency drift in temperature range +5 °C to +45 °C ±5 × 10–8 Retrace at +25 °C,

after 24 hours power ON / 2 hours power OFF / 1 hour power ON

±2 × 10–8

Max. aging at +25 °C, after 10 days of continuous operation

±1 × 10–7/year ±1 × 10–9/day

Warm-up time at +25 °C, the frequency is in the range that is 10 times the frequency drift (±5 × 10–7)

approx. 10 min

Timebase highly stable OCXO (R&S®CMW-B690B option) in temperature range +5 °C to +45 °C, referenced to +25 °C

±5 × 10–9 Max. frequency drift

with instrument orientation ±1 × 10–9 Retrace at +25 °C,

after 24 hours power ON / 2 hours power OFF / 1 hour power ON

±5 × 10–9

Max. aging at +25 °C, after 10 days of continuous operation

±3 × 10–8/year ±5 × 10–10/day

Warm-up time at +25 °C, the frequency is in the range that is 10 times the frequency drift (±5 × 10–8)

approx. 10 min

Reference frequency inputs/outputs Synchronization input BNC connector REF IN, rear panel

sinewave 10 MHz to 80 MHz, step: 1 Hz Frequency squarewave (TTL level) 1 MHz to 80 MHz, step: 1 Hz

Max. frequency variation ±10 × 10–6 Input voltage range 0.5 V to 2 V, rms Impedance 50 Ω

Synchronization output 1 BNC connector REF OUT 1, rear panel Frequency 10 MHz from internal reference or

frequency at synchronization input Output voltage >1.4 V, peak-to-peak Impedance 50 Ω

Page 11: R&S®CMW500 Test & Measurement Data Sheet | 05.00 … · Wideband Radio Communication Tester Specifications ... WCDMA specifications ... except fnonharmonic = 3900 MHz

Version 05.00, November 2008 R&S®CMW500 Wideband Radio Communication Tester 11

GSM specifications – mobile station test

GSM RF generator (prerequisite: R&S®CMW-B110A option) GSM450 band 460 MHz to 468 MHz GSM480 band 488 MHz to 496 MHz GSM750 band 747 MHz to 762 MHz GSM850 band 869 MHz to 894 MHz GSM900 band 921 MHz to 960 MHz GSM1800 band 1805 MHz to 1880 MHz

Frequency range

GSM1900 band 1930 MHz to 1990 MHz

GSM GEN (R&S®CMW-KG200 option) Output level range depending on PAR see general technical specifications Output level uncertainty see general technical specifications Output level resolution see general technical specifications

Signal quality <1°, rms Phase error GMSK <4°, peak

Error vector magnitude (EVM) 8PSK <2 %, rms

GSM WINIQSIM2 (R&S®CMW-KW200 option) GMSK, B × T = 0.3 GSM_GMSK.WV (PAR = 0 dB),

GMSKDIGMOD.WV (PAR = 0 dB) Arbitrary waveform files

8PSK GSM_EDGE.WV (PAR = 3.23 dB), EDGEDIGMOD.WV (PAR = 3.22 dB)

Output level range depending on PAR see general technical specifications Output level uncertainty waveform file used:

GMSKDIGMOD.WV or EDGEDIGMOD.WV

see general technical specifications

Output level resolution see general technical specifications

Signal quality <1°, rms Phase error GMSK

waveform file used: GSM_GMSK.WV <4°, peak Error vector magnitude (EVM) 8PSK

waveform file used: GSM_EDGE.WV <2 %, rms

GSM RF analyzer (R&S®CMW-KM200 option) GSM450 band 450 MHz to 458 MHz GSM480 band 478 MHz to 486 MHz GSM750 band 777 MHz to 792 MHz GSM850 band 824 MHz to 849 MHz GSM900 band 876 MHz to 915 MHz GSM1800 band 1710 MHz to 1785 MHz

Frequency range

GSM1900 band 1850 MHz to 1910 MHz

Trigger Trigger sources BASE: external TRIG A,

BASE: external TRIG B, GPRF: BB generator, GSM: free run, GSM: IF power, GSM: acquisition

Page 12: R&S®CMW500 Test & Measurement Data Sheet | 05.00 … · Wideband Radio Communication Tester Specifications ... WCDMA specifications ... except fnonharmonic = 3900 MHz

12 R&S®CMW500 Wideband Radio Communication Tester Version 05.00, November 2008

Modulation analysis Level range –28 dBm to +42 dBm 7

<0.6°, rms Inherent phase error GMSK <2°, peak

Inherent EVM 8PSK <0.8 %, rms Frequency measurement uncertainty <35 Hz + drift of timebase,

see general technical specifications Inherent I/Q offset <–50 dB

GMSK bandpass, 900 kHz, RRC filter, α = 0.16 Filter 8PSK windowed raised-cosine filter in line with

3GPP TS 45.005

Burst power measurement Level uncertainty bandpass, 900 kHz, RRC filter, α = 0.16 see general technical specifications

Power versus time measurement Filter selectable Gaussian, 500 kHz or 1 MHz

filter → 500 kHz, Gaussian, with fixed expected nominal power setting

GMSK >72 dB, rms

Dynamic range

8PSK >69 dB, rms Expected nominal power setting for full dynamic range

RF1 COM, RF2 COM –8 dBm to +42 dBm 7

result >–40 dB typ. <0.1 dB Relative measurement uncertainty –60 dB ≤ result ≤ –40 dB typ. <0.5 dB

Burst power measurement Level range –50 dBm to +42 dBm 7 Level uncertainty filter → 500 kHz or 1 MHz, Gaussian see general technical specifications

Spectrum due to modulation measurement Expected nominal power setting for full dynamic range

RF1 COM, RF2 COM –8 dBm to +42 dBm 7

Test method relative measurement, averaging Filter Gaussian, 30 kHz, 5 pole Measurement at an offset of ± 100/200/250/400/600/800/1000/1200/1400

/1600/1800 kHz

offset ≥ 1200 kHz GMSK >74 dB

Dynamic range

8PSK >70 dB

Spectrum due to switching measurement Expected nominal power setting for full dynamic range

RF1 COM, RF2 COM –8 dBm to +42 dBm 7

Test method absolute measurement, Max Hold Filter Gaussian, 30 kHz, 5 pole Measurement at an offset of ± 400/600/1200/1800 kHz

offset ≥ 1200 kHz GMSK >72 dB

Dynamic range

8PSK >68 dB

7 The maximum permissible continuous power is +34 dBm due to thermal limits.

Page 13: R&S®CMW500 Test & Measurement Data Sheet | 05.00 … · Wideband Radio Communication Tester Specifications ... WCDMA specifications ... except fnonharmonic = 3900 MHz

Version 05.00, November 2008 R&S®CMW500 Wideband Radio Communication Tester 13

WCDMA specifications – mobile station (UE) test Standard 3GPP FDD

WCDMA RF generator (prerequisite: R&S®CMW-B110A option) WCDMA band 1 2110 MHz to 2170 MHz WCDMA band 2 1930 MHz to 1990 MHz WCDMA band 3 1805 MHz to 1880 MHz WCDMA band 4 2110 MHz to 2155 MHz WCDMA band 5 869 MHz to 894 MHz WCDMA band 6 875 MHz to 885 MHz WCDMA band 7 2620 MHz to 2690 MHz WCDMA band 8 925 MHz to 960 MHz WCDMA band 9 1844.9 MHz to 1879.9 MHz WCDMA band 10 2110 MHz to 2170 MHz WCDMA band 11 1475.9 MHz to 1500.9 MHz WCDMA band 12 728 MHz to 746 MHz WCDMA band 13 746 MHz to 756 MHz

Frequency range

WCDMA band 14 758 MHz to 768 MHz

WCDMA GEN (R&S®CMW-KG400 option), WCDMA HSPA GEN (R&S®CMW-KG401 option) Output level range depending on PAR see general technical specifications Output level uncertainty see general technical specifications Output level resolution see general technical specifications

Signal quality Error vector magnitude (EVM) composite EVM <4 %, rms

WCDMA WINIQSIM2 (R&S®CMW-KW400 option), WCDMA HSDPA WINIQSIM2 (R&S®CMW-KW401 option), WCDMA HSUPA WINIQSIM2 (R&S®CMW-KW402 option)

with R&S®CMW-KW400 option TM4CPICH.WV (PAR = 8.34 dB), 3GPPDEFAULT.WV (PAR = 10.65 dB)

with R&S®CMW-KW401 option WCDMA_DL_HSDPA.WV (PAR = 10.08 dB)

Arbitrary waveform files

with R&S®CMW-KW402 option WCDMA_DL_HSUPA.WV (PAR = 10.12 dB)

Output level range depending on PAR see general technical specifications with R&S®CMW-KW400 option waveform file used: 3GPPDEFAULT.WV

see general technical specifications

with R&S®CMW-KW401 option waveform file used: WCDMA_DL_HSDPA.WV

see general technical specifications

Output level uncertainty

with R&S®CMW-KW402 option waveform file used: WCDMA_DL_HSUPA.WV

see general technical specifications

Output level resolution see general technical specifications

Signal quality composite EVM, with R&S®CMW-KW400 option waveform file used: 3GPPDEFAULT.WV

<4 %, rms

composite EVM, with R&S®CMW-KW401 option waveform file used: WCDMA_DL_HSDPA.WV,

<4 %, rms

Error vector magnitude (EVM)

composite EVM, with R&S®CMW-KW402 option waveform file used: WCDMA_DL_HSUPA.WV

<4 %, rms

Page 14: R&S®CMW500 Test & Measurement Data Sheet | 05.00 … · Wideband Radio Communication Tester Specifications ... WCDMA specifications ... except fnonharmonic = 3900 MHz

14 R&S®CMW500 Wideband Radio Communication Tester Version 05.00, November 2008

WCDMA RF analyzer (R&S®CMW-KM400 option and R&S®CMW-KM401 option)

WCDMA band 1 1920 MHz to 1980 MHz WCDMA band 2 1850 MHz to 1910 MHz WCDMA band 3 1710 MHz to 1785 MHz WCDMA band 4 1710 MHz to 1755 MHz WCDMA band 5 824 MHz to 849 MHz WCDMA band 6 830 MHz to 840 MHz WCDMA band 7 2500 MHz to 2570 MHz WCDMA band 8 880 MHz to 915 MHz WCDMA band 9 1749.9 MHz to 1784.9 MHz WCDMA band 10 1710 MHz to 1770 MHz WCDMA band 11 1427.9 MHz to 1452.9 MHz WCDMA band 12 698 MHz to 716 MHz WCDMA band 13 777 MHz to 787 MHz

Frequency range

WCDMA band 14 788 MHz to 798 MHz Statistics Statistical count 1 to 1000 Values current, average, minimum/maximum,

standard deviation Trigger Trigger sources BASE: external TRIG A,

BASE: external TRIG B, GPRF: BB generator, WCDMA: free run, WCDMA: free run (fast sync), WCDMA: IF power, WCDMA: DCCH TTI trigger, WCDMA: frame trigger, WCDMA: HS-DPCCH trigger, WCDMA: slot trigger

Modulation analysis Filter 3.84 MHz, RRC, α = 0.22, WCDMA filter Level range –28 dBm to +42 dBm 8

with R&S®CMW-KM400 option QPSK, WCDMA Analysis modes with R&S®CMW-KM400 option and R&S®CMW-KM401 option

WCDMA + HSDPA, WCDMA + HSUPA, WCDMA + HSPA

numeric results and standard deviation error vector magnitude (EVM), magnitude error (ME), phase error (PE), frequency error, I/Q origin offset, I/Q imbalance, UE power, power steps, phase discontinuity, CDP, CDE

Measured parameters

graphical EVM versus time, EVM versus chip, ME versus time, ME versus chip, PE versus time, PE versus chip, FE versus time, UE versus time, PS versus slot, PD versus slot, CDP versus slot, CDE versus slot, CD monitor

8 The maximum permissible continuous power is +34 dBm due to thermal limits.

Page 15: R&S®CMW500 Test & Measurement Data Sheet | 05.00 … · Wideband Radio Communication Tester Specifications ... WCDMA specifications ... except fnonharmonic = 3900 MHz

Version 05.00, November 2008 R&S®CMW500 Wideband Radio Communication Tester 15

Error vector magnitude (EVM) Measurement range up to 25 %, rms Inherent EVM <2.5 %, rms Measurement length half-slot, 1 slot, multislot (1 to 120)

Frequency error Measurement range ±3 kHz Frequency measurement uncertainty

<35 Hz + drift of timebase, see general technical specifications

I/Q origin offset Inherent I/Q offset for average ≥10 measurements <–55 dB

I/Q imbalance Inherent I/Q imbalance <–50 dB

Spectrum measurements Adjacent channel leakage ratio rms detector Filter 3.84 MHz, RRC, α = 0.22, WCDMA filter

first adjacent channel at ±5 MHz >54 dB Dynamic range second adjacent channel at ±10 MHz >57 dB

Expected nominal power setting for full dynamic range

RF1 COM, RF2 COM –4 dBm to +42 dBm 9

for –33 dBc first adjacent channel level <0.5 dB Uncertainty for –43 dBc second adjacent channel level <0.5 dB

Measurement length 1 slot (2560 chips)

Power meter UE power measurement rms detector Filter bandpass, 6.3 MHz, RRC, α = 0.22 Level range –55 dBm to +42 dBm 9 Level uncertainty see general technical specifications Measurement length half-slot, 1 slot

Off power measurement rms detector Filter 3.84 MHz, RRC, α = 0.22, WCDMA filter Noise floor –72 dBm Level uncertainty see general technical specifications +

uncertainty due to noise floor

9 The maximum permissible continuous power is +34 dBm due to thermal limits.

Page 16: R&S®CMW500 Test & Measurement Data Sheet | 05.00 … · Wideband Radio Communication Tester Specifications ... WCDMA specifications ... except fnonharmonic = 3900 MHz

16 R&S®CMW500 Wideband Radio Communication Tester Version 05.00, November 2008

GPS specifications Standard GPS

GPS RF generator (prerequisite: R&S®CMW-B110A option) GPS band

L1 1575.42 MHz Frequency range

L2 1227.6 MHz

GPS WINIQSIM2 (R&S®CMW-KW620 option) Arbitrary waveform file GPS_DEFAULT.WV (PAR = 3.66 dB)

Output level range depending on PAR see general technical specifications Output level uncertainty waveform file used:

GPS_DEFAULT.WV see general technical specifications

Output level resolution see general technical specifications

DVB specifications Standard DVB-T

DVB RF generator (prerequisite: R&S®CMW-B110A option) VHF band III

channels 5 to 12 174 MHz to 230 MHz UHF band IV

channels 21 to 34 470 MHz to 582 MHz UHF band V

Frequency range

channels 35 to 69 582 MHz to 862 MHz

DVB WINIQSIM2 (R&S®CMW-KW630 option) Arbitrary waveform file DVB-T_SCRAMBLED_16QAM_3SEC_

TESTFILE.WV (PAR = 13.23 dB) Output level range depending on PAR see general technical specifications Output level uncertainty waveform file used:

DVB-T_SCRAMBLED_16QAM_3SEC_ TESTFILE.WV

see general technical specifications

Output level resolution see general technical specifications

Page 17: R&S®CMW500 Test & Measurement Data Sheet | 05.00 … · Wideband Radio Communication Tester Specifications ... WCDMA specifications ... except fnonharmonic = 3900 MHz

Version 05.00, November 2008 R&S®CMW500 Wideband Radio Communication Tester 17

TD-SCDMA specifications – mobile station (UE) test Standard TD-SCDMA CWTS

TD-SCDMA RF generator (prerequisite: R&S®CMW-B110A option) TD-SCDMA band I

channels 9512 to 9588 1900 MHz to 1920 MHz channels 10062 to 10113 2010 MHz to 2025 MHz

TD-SCDMA band II channels 9262 to 9538 1850 MHz to 1910 MHz channels 9662 to 9938 1930 MHz to 1990 MHz

TD-SCDMA band III

Frequency range

channels 9562 to 9638 1910 MHz to 1930 MHz

TD-SCDMA WINIQSIM2 (R&S®CMW-KW750 option) and TD-SCDMA ENH. WINIQSIM2 (R&S®CMW-KW751 option)

with R&S®CMW-KW750 TD-SCDMA_DEFAULT.WV (PAR = 3.14 dB), TD-SCDMA_PTWLOW.WV (PAR = 2.67 dB)

Arbitrary waveform files

with R&S®CMW-KW750 and R&S®CMW-KW751

TD-SCDMA-DL_12K2.WV (PAR = 5.41 dB)

Output level range depending on PAR see general technical specifications Output level uncertainty waveform file used:

TD-SCDMA_PTWLOW.WV see general technical specifications

Output level resolution see general technical specifications Signal quality Error vector magnitude (EVM) composite EVM,

waveform file used: TD-SCDMA_DEFAULT.WV

<4 %, rms

TD-SCDMA RF analyzer (R&S®CMW-KM750 option) TD-SCDMA band I

channels 9512 to 9588 1900 MHz to 1920 MHz channels 10062 to 10113 2010 MHz to 2025 MHz

TD-SCDMA band II channels 9262 to 9538 1850 MHz to 1910 MHz channels 9662 to 9938 1930 MHz to 1990 MHz

TD-SCDMA band III

Frequency range

channels 9562 to 9638 1910 MHz to 1930 MHz Statistics Statistical count 1 to 1000 Values current, average, minimum/maximum,

standard deviation Trigger Trigger sources BASE: external TRIG A,

BASE: external TRIG B, GPRF: BB generator, TD-SCDMA: free run, TD-CDMA: IF power

Page 18: R&S®CMW500 Test & Measurement Data Sheet | 05.00 … · Wideband Radio Communication Tester Specifications ... WCDMA specifications ... except fnonharmonic = 3900 MHz

18 R&S®CMW500 Wideband Radio Communication Tester Version 05.00, November 2008

Modulation analysis Filter

1.28 MHz, RRC, α = 0.22, TD-SCDMA filter

Level range –28 dBm to +42 dBm 10 Analysis modes TD-SCDMA uplink DPCH,

DPCH + HSDPA numeric results and standard deviation error vector magnitude (EVM),

magnitude error (ME), phase error (PE), frequency error, I/Q origin offset, I/Q imbalance, UE power

Measured parameters

graphical EVM versus time, ME versus time, PE versus time

Error vector magnitude (EVM) Measurement range up to 25 %, rms Inherent EVM <2.5 %, rms Measurement length 1 slot, multislot (1 to 112)

Frequency error Measurement range ±3 kHz Frequency measurement uncertainty <35 Hz + drift of timebase,

see general technical specifications I/Q origin offset Inherent I/Q offset for average ≥10 measurements <–55 dB

I/Q imbalance Inherent I/Q imbalance <–50 dB

10 The maximum permissible continuous power is +34 dBm due to thermal limits.

Page 19: R&S®CMW500 Test & Measurement Data Sheet | 05.00 … · Wideband Radio Communication Tester Specifications ... WCDMA specifications ... except fnonharmonic = 3900 MHz

Version 05.00, November 2008 R&S®CMW500 Wideband Radio Communication Tester 19

Code domain Filter

1.28 MHz, RRC, α = 0.22, TD-SCDMA filter

Level range –28 dBm to +42 dBm 11 Analysis modes TD-SCDMA uplink DPCH,

DPCH + HSDPA numeric results and standard deviation code domain error (CDE) Measured parameters graphical code domain power versus code

Code domain power versus code Uncertainty <0.4 dB Measurement length 1 slot

Code domain error (CDE) Uncertainty <0.4 dB Measurement length 1 slot

Spectrum measurements Adjacent channel leakage ratio rms detector Filter

1.28 MHz, RRC, α = 0.22, TD-SCDMA filter

first adjacent channel at ±1.6 MHz >53 dB Dynamic range second adjacent channel at ±3.2 MHz >61 dB

Expected nominal power setting for full dynamic range

RF1 COM, RF2 COM –3 dBm to +42 dBm 11

for –33 dBc first adjacent channel level <0.5 dB Uncertainty for –43 dBc second adjacent channel level <0.5 dB

Measurement length 1 slot

Power meter Measured parameters numeric current rms values UE power

UE power rms detector Filter bandpass, 2.1 MHz, RRC, α = 0.22 Level range –55 dBm to +42 dBm 11 Level uncertainty see general technical specifications Measurement length 1 slot

11 The maximum permissible continuous power is +34 dBm due to thermal limits.

Page 20: R&S®CMW500 Test & Measurement Data Sheet | 05.00 … · Wideband Radio Communication Tester Specifications ... WCDMA specifications ... except fnonharmonic = 3900 MHz

20 R&S®CMW500 Wideband Radio Communication Tester Version 05.00, November 2008

CDMA2000® 1xRTT specifications – mobile station test CDMA2000® standards TIA/EIA IS-2000 Rev. 0 Standard CDMA2000® test standards TIA/EIA IS-98-F

Symbol rate 1.2288 Mcps

CDMA2000® 1xRTT RF generator (prerequisite: R&S®CMW-B110A option) band class 0 860.025 MHz to 893.985 MHz band class 1 1930.000 MHz to 1990.000 MHz band class 2 917.0125 MHz to 959.9875 MHz band class 3 832.0125 MHz to 869.9875 MHz band class 4 1840.000 MHz to 1870.000 MHz band class 5 421.675 MHz to 493.480 MHz band class 6 2110.000 MHz to 2169.950 MHz band class 7 746.000 MHz to 764.000 MHz band class 8 1805.000 MHz to 1879.950 MHz band class 9 925.000 MHz to 958.750 MHz band class 10 851.000 MHz to 939.975 MHz band class 11 421.675 MHz to 493.475 MHz band class 12 915.0125 MHz to 920.9875 MHz band class 13 2620.000 MHz to 2690 MHz band class 14 1930.000 MHz to 1995.000 MHz band class 15 2110.000 MHz to 2155.000 MHz band class 16 2624.000 MHz to 2690.000 MHz

Frequency range

band class 17 2624.000 MHz to 2690.000 MHz

CDMA2000® WINIQSIM2 (R&S®CMW-KW800 option) Arbitrary waveform files CDMA_OQPSK.WV (PAR = 5.54 dB) or

CDMA_HPSK.WV (PAR = 6.97 dB) Output level range depending on PAR see general technical specifications Output level uncertainty waveform file used:

CDMA_OQPSK.WV or CDMA_HPSK.WV see general technical specifications

Output level resolution see general technical specifications Signal quality Waveform quality (rho) waveform file used:

CDMA_OQPSK.WV or CDMA_HPSK.WV >0.99

CDMA2000® RF analyzer (R&S®CMW-KM800 option) band class 0 815.025 MHz to 848.985 MHz band class 1 1850.000 MHz to 1910.000 MHz band class 2 872.0125 MHz to 914.9875 MHz band class 3 887.0125 MHz to 924.9875 MHz band class 4 1750.000 MHz to 1780.000 MHz band class 5 411.675 MHz to 483.480 MHz band class 6 1920.000 MHz to 1979.950 MHz band class 7 776.000 MHz to 794.000 MHz band class 8 1710.000 MHz to 1784.950 MHz band class 9 880.000 MHz to 913.750 MHz band class 10 806.000 MHz to 900.975 MHz band class 11 411.675 MHz to 483.475 MHz band class 12 870.0125 MHz to 875.9875 MHz band class 13 2500.000 MHz to 2570.000 MHz band class 14 1850.000 MHz to 1915.000 MHz band class 15 1710.000 MHz to 1755.000 MHz

Frequency range

band class 16 2502.000 MHz to 2568.000 MHz

Page 21: R&S®CMW500 Test & Measurement Data Sheet | 05.00 … · Wideband Radio Communication Tester Specifications ... WCDMA specifications ... except fnonharmonic = 3900 MHz

Version 05.00, November 2008 R&S®CMW500 Wideband Radio Communication Tester 21

Statistics Statistical count 1 to 1000 Values current, average, minimum/maximum,

standard deviation Trigger Trigger sources BASE: external TRIG A,

BASE: external TRIG B, GPRF: BB generator, C2K: free run

Modulation analysis Filter 1.23 MHz, RRC, α = 0.22, CDMA filter Level range –28 dBm to +42 dBm 12 Analysis modes O-QPSK, HPSK

numeric results and standard deviation error vector magnitude (EVM), magnitude error (ME), phase error (PE), frequency error, rho, carrier feedthrough, I/Q imbalance, power, wideband power (8 MHz), narrowband power (1.23 MHz)

Measured parameters

graphical EVM versus time, ME versus time, PE versus time

Waveform quality (rho) Uncertainty for rho 0.9 to 1 <0.003 Measurement length 616 chips (0.5 ms)

Error vector magnitude (EVM) Measurement range up to 25 %, rms Inherent EVM <2.5 %, rms Measurement length 0.5 ms

Frequency error Measurement range ±3 kHz Frequency measurement uncertainty <35 Hz + drift of timebase,

see general technical specifications Carrier feedthrough Inherent carrier feedthrough for average ≥10 measurements <–55 dB

I/Q imbalance Inherent I/Q imbalance <–50 dB

12 The maximum permissible continuous power is +34 dBm due to thermal limits.

Page 22: R&S®CMW500 Test & Measurement Data Sheet | 05.00 … · Wideband Radio Communication Tester Specifications ... WCDMA specifications ... except fnonharmonic = 3900 MHz

22 R&S®CMW500 Wideband Radio Communication Tester Version 05.00, November 2008

Code domain Filter 1.23 MHz, RRC, α = 0.22, CDMA filter Level range –28 dBm to +42 dBm 13

numeric values of current, average, max. and min. values

code domain power (CDP), code domain error (CDE)

Measured parameters

graphical code domain power versus code, code domain error versus code

Code domain power versus code Uncertainty <0.4 dB Measurement length 616 chips (0.5 ms)

Code domain error versus code Measurement uncertainty <0.4 dB Measurement length 616 chips (0.5 ms)

Spectrum measurements Adjacent channel power rms detector, at the selected frequency

offsets

Filter 30 kHz Gaussian Frequency offset interval up to 10 adjacent channels on each side –4 MHz to +4 MHz Dynamic range >70 dB Expected nominal power setting for full dynamic range

RF1 COM, RF2 COM +1 dBm to +42 dBm 13

Uncertainty for –43 dBc adjacent channel level <0.5 dB Measurement length one power control group 1536 chips (1.25 ms)

Power meter MS power Filter narrowband bandpass, 1.25 MHz Filter wideband bandpass, 8 MHz Level range –55 dBm to +42 dBm 13 Level uncertainty see general technical specifications Measurement length 616 chips (0.5 ms)

13 The maximum permissible continuous power is +34 dBm due to thermal limits.

Page 23: R&S®CMW500 Test & Measurement Data Sheet | 05.00 … · Wideband Radio Communication Tester Specifications ... WCDMA specifications ... except fnonharmonic = 3900 MHz

Version 05.00, November 2008 R&S®CMW500 Wideband Radio Communication Tester 23

CDMA2000® 1xEV-DO specifications – access terminal test CDMA2000® 1xEV-DO standards TIA/EIA 856-2 Standard CDMA2000® 1xEV-DO test standards TIA/EIA 866-A

Symbol rate 1.2288 Mcps

CDMA2000® 1xEV-DO RF generator (prerequisite: R&S®CMW-B110A option) band class 0 860.025 MHz to 893.985 MHz band class 1 1930.000 MHz to 1990.000 MHz band class 2 917.0125 MHz to 959.9875 MHz band class 3 832.0125 MHz to 869.9875 MHz band class 4 1840.000 MHz to 1870.000 MHz band class 5 421.675 MHz to 493.480 MHz band class 6 2110.000 MHz to 2169.950 MHz band class 7 746.000 MHz to 764.000 MHz band class 8 1805.000 MHz to 1879.950 MHz band class 9 925.000 MHz to 958.750 MHz band class 10 851.000 MHz to 939.975 MHz band class 11 421.675 MHz to 493.475 MHz band class 12 915.0125 MHz to 920.9875 MHz band class 13 2620.000 MHz to 2690 MHz band class 14 1930.000 MHz to 1995.000 MHz band class 15 2110.000 MHz to 2155.000 MHz band class 16 2624.000 MHz to 2690.000 MHz

Frequency range

band class 17 2624.000 MHz to 2690.000 MHz

1xEV-DO WINIQSIM2 (R&S®CMW-KW880 option) Arbitrary waveform files EVDO_DEFAULT.WV (PAR = 4.86 dB)

Output level range depending on PAR see general technical specifications Output level uncertainty waveform file used: EVDO_DEFAULT.WV see general technical specifications Output level resolution see general technical specifications

Signal quality Waveform quality (rho) waveform file used: EVDO_DEFAULT.WV >0.99

CDMA2000® 1xEV-DO RF analyzer (R&S®CMW-KM880 option) band class 0 815.025 MHz to 848.985 MHz band class 1 1850.000 MHz to 1910.000 MHz band class 2 872.0125 MHz to 914.9875 MHz band class 3 887.0125 MHz to 924.9875 MHz band class 4 1750.000 MHz to 1780.000 MHz band class 5 411.675 MHz to 483.480 MHz band class 6 1920.000 MHz to 1979.950 MHz band class 7 776.000 MHz to 794.000 MHz band class 8 1710.000 MHz to 1784.950 MHz band class 9 880.000 MHz to 913.750 MHz band class 10 806.000 MHz to 900.975 MHz band class 11 411.675 MHz to 483.475 MHz band class 12 870.0125 MHz to 875.9875 MHz band class 13 2500.000 MHz to 2570.000 MHz band class 14 1850.000 MHz to 1915.000 MHz band class 15 1710.000 MHz to 1755.000 MHz

Frequency range

band class 16 2502.000 MHz to 2568.000 MHz

Page 24: R&S®CMW500 Test & Measurement Data Sheet | 05.00 … · Wideband Radio Communication Tester Specifications ... WCDMA specifications ... except fnonharmonic = 3900 MHz

24 R&S®CMW500 Wideband Radio Communication Tester Version 05.00, November 2008

Statistics Statistical count 1 to 1000 Values current, average, minimum/maximum,

standard deviation

Trigger Trigger sources BASE: external TRIG A,

BASE: external TRIG B, GPRF: BB generator, 1xEV-DO: free run

Modulation analysis Filter 1.23 MHz, RRC, α = 0.22, CDMA filter Level range –28 dBm to +42 dBm 14 Analysis modes dual BPSK

numeric results and standard deviation error vector magnitude (EVM), magnitude error (ME), phase error (PE), frequency error, rho, carrier feedthrough, I/Q imbalance, power, wideband power (8 MHz), narrowband power (1.23 MHz)

Measured parameters

graphical EVM versus time, ME versus time, PE versus time

Waveform quality (rho) Uncertainty for rho 0.9 to 1 <0.003 Measurement length half-slot 1024 chips (833.33 µs)

Error vector magnitude (EVM) Measurement range up to 25 %, rms Inherent EVM <2.5 %, rms Measurement length half-slot 1024 chips (833.33 µs)

Frequency error Measurement range ±3 kHz Frequency measurement uncertainty <35 Hz + drift of timebase,

see general technical specifications

Carrier feedthrough Inherent carrier feedthrough for average ≥10 measurements <–55 dB

I/Q imbalance Inherent I/Q imbalance <–50 dB

14 The maximum permissible continuous power is +34 dBm due to thermal limits.

Page 25: R&S®CMW500 Test & Measurement Data Sheet | 05.00 … · Wideband Radio Communication Tester Specifications ... WCDMA specifications ... except fnonharmonic = 3900 MHz

Version 05.00, November 2008 R&S®CMW500 Wideband Radio Communication Tester 25

Code domain Filter 1.23 MHz, RRC, α = 0.22, CDMA filter Level range –28 dBm to +42 dBm 15

numeric values of current, average, max. and min. values

code domain power (CDP), code domain error (CDE)

Measured parameters

graphical code domain power versus code, code domain error versus code

Code domain power versus code Uncertainty <0.4 dB Measurement length half-slot 1024 chips (833.33 µs)

Code domain error versus code Measurement uncertainty <0.4 dB Measurement length half-slot 1024 chips (833.33 µs)

Spectrum measurements Adjacent channel power rms detector, at the selected frequency

offsets

Filter 30 kHz Gaussian Frequency offset interval up to 10 adjacent channels on each side –4 MHz to +4 MHz Dynamic range >70 dB Expected nominal power setting for full dynamic range

RF1 COM, RF2 COM +1 dBm to +42 dBm 15

Uncertainty for –43 dBc adjacent channel level <0.5 dB Measurement length half-slot 1024 chips (833.33 µs)

Power meter MS power Filter narrowband bandpass, 1.25 MHz Filter wideband bandpass, 8 MHz Level range –55 dBm to +42 dBm 15 Level uncertainty see general technical specifications Measurement length half-slot 1024 chips (833.33 µs)

15 The maximum permissible continuous power is +34 dBm due to thermal limits.

Page 26: R&S®CMW500 Test & Measurement Data Sheet | 05.00 … · Wideband Radio Communication Tester Specifications ... WCDMA specifications ... except fnonharmonic = 3900 MHz

26 R&S®CMW500 Wideband Radio Communication Tester Version 05.00, November 2008

WiMAX® specifications – mobile station test Standard IEEE 802.16e-2005, OFDMA

WiMAX® RF generator (prerequisite: R&S®CMW-B110A option) WiMAX band 1 2300 MHz to 2800 MHz WiMAX band 2, prerequisite: R&S®CMW-KB036 option

3300 MHz to 3800 MHz Frequency range

WiMAX band 3, prerequisite: R&S®CMW-KB036 option

5100 MHz to 5850 MHz

WiMAX® WINIQSIM2 (R&S®CMW-KW700 option) Arbitrary waveform file in line with IEEE 802.16e-2005,

OFDMA average power WIMAX_DL_3-BURST_46_5MS.WV (PAR = 11.11 dB)

Output level range depending on PAR see general technical specifications Output level uncertainty waveform file used:

WIMAX_DL_3-BURST_46_5MS.WV add 0.15 dB to RF generator level uncertainty (see general technical specifications)

Output level resolution see general technical specifications Signal quality Error vector magnitude (EVM) ID_Cell = 0, permbase = 0, prbs_id = 0,

cp = 1/8, BW = 10 MHz, bursts: FCH, DL-MAP, data PN15, modulation type and coding rate QPSK 1/2; waveform file used: WIMAX_DL_3BURST_46_5MS.WV

<–40 dB, rms

WiMAX® RF analyzer (R&S®CMW-KM700 option) FFT size 512, 1024 Bandwidth 3.5 MHz, 5 MHz, 7 MHz, 8.75 MHz,

10 MHz Link direction uplink, downlink Subcarrier allocation DL PUSC, UL PUSC

WiMAX band 1 2300 MHz to 2800 MHz WiMAX band 2, prerequisite: R&S®CMW-KB036 option

3300 MHz to 3800 MHz Frequency range

WiMAX band 3, prerequisite: R&S®CMW-KB036 option

5100 MHz to 5580 MHz and 5620 MHz to 5850 MHz

Level setting manual mode Level range RF1 COM, RF2 COM –40 dBm to +27 dBm, rms

Statistics Statistical count 1 to 1000 Values current, average, minimum, maximum

Trigger Trigger source WiMAX: IF power

Measured parameters numeric results subframe rms power,

crest factor, error vector magnitude (all carriers, pilot carriers, data carriers), frequency error, I/Q imbalance gain, I/Q imbalance quadrature, spectrum flatness, relative

Page 27: R&S®CMW500 Test & Measurement Data Sheet | 05.00 … · Wideband Radio Communication Tester Specifications ... WCDMA specifications ... except fnonharmonic = 3900 MHz

Version 05.00, November 2008 R&S®CMW500 Wideband Radio Communication Tester 27

Power measurement Subframe rms power Level uncertainty RF1 COM, RF2 COM,

WiMAX band 1, band 2, and band 3 add 0.15 dB to RF analyzer level uncertainty (see general technical specifications) 16

Modulation analysis Error vector magnitude Measurement range from inherent EVM up to –12 dB

WiMAX band 1 UL –15 dBm ≤ input level ≤ +27 dBm <–40 dB, rms 16 –40 dBm ≤ input level < –15 dBm <–36 dB, rms 16

WiMAX band 2 UL –15 dBm ≤ input level ≤ +27 dBm <–38 dB, rms 16 –35 dBm ≤ input level < –15 dBm <–35 dB, rms 16

WiMAX band 3 UL –15 dBm ≤ input level ≤ +27 dBm <–38 dB, rms 16 –35 dBm ≤ input level < –15 dBm <–35 dB, rms 16

WiMAX band 1 DL –15 dBm ≤ input level ≤ +27 dBm <–38 dB, rms 16

WiMAX band 2 DL –15 dBm ≤ input level ≤ +27 dBm <–36 dB, rms 16

WiMAX band 3 DL

Inherent EVM

–15 dBm ≤ input level ≤ +27 dBm <–36 dB, rms 16 Measurement length 1 frame, multiframe Resolution 0.01 dB

Frequency error

FFT size 512, BW = 3.5 MHz –3.9063 kHz to +3.9063 kHz FFT size 512, BW = 5 MHz –5.468 kHz to +5.468 kHz FFT size 1024, BW = 7 MHz –3.9063 kHz to +3.9063 kHz FFT size 1024, BW = 8.75 MHz –4.8828 kHz to +4.8828 kHz

Measurement range

FFT size 1024, BW = 10 MHz –5.468 kHz to +5.468 kHz Frequency measurement uncertainty <10 Hz + drift of timebase,

see general technical specifications 16 Resolution 0.01 Hz

I/Q imbalance Inherent I/Q gain imbalance <0.1 dB 16 I/Q gain imbalance resolution 0.001 dB Inherent I/Q quadrature imbalance <0.1° rms 16 I/Q quadrature imbalance resolution 0.001°

16 Averaging across 100 bursts, UL signal definition: BW = 10 MHz, NFFT = 1024, all subchannels used, zone length: 34 DL, 18 UL.

Page 28: R&S®CMW500 Test & Measurement Data Sheet | 05.00 … · Wideband Radio Communication Tester Specifications ... WCDMA specifications ... except fnonharmonic = 3900 MHz

28 R&S®CMW500 Wideband Radio Communication Tester Version 05.00, November 2008

Spectrum measurements Spectrum flatness, relative

inner carriers: spectral lines from –Nused/4 to –1 and spectral lines from 1 to Nused/4

<0.6 dB 17

outer carriers: spectral lines from –Nused/2 to –Nused/4 and spectral lines from Nused/4 to Nused/2

<1.1 dB 17

Level uncertainty

neighbor subcarrier deviation <0.2 dB 17 Resolution 0.01 dB

Adjacent channel leakage ratio rms detector Filter rectangle 5 MHz, 10 MHz Dynamic range first adjacent channel >45 dB Expected nominal power setting for full dynamic range

RF1 COM, RF2 COM >–3 dBm

SEM rms detector Frequency span 40 MHz Supported masks IEEE Dynamic range >50 dB Expected nominal power setting for full dynamic range

RF1 COM, RF2 COM >–3 dBm

17 Averaging across 100 bursts, UL signal definition: BW = 10 MHz, NFFT = 1024, all subchannels used, zone length: 34 DL, 18 UL.

Page 29: R&S®CMW500 Test & Measurement Data Sheet | 05.00 … · Wideband Radio Communication Tester Specifications ... WCDMA specifications ... except fnonharmonic = 3900 MHz

Version 05.00, November 2008 R&S®CMW500 Wideband Radio Communication Tester 29

Digital I/Q 1 to 4 (R&S®CMW-B510A option) 18 The R&S®CMW-B510A makes the digital I/Q interface and AUX interface available on the rear of the instrument.

Digital I/Q interface The digital I/Q interface can be used for connecting the R&S®CMW to the digital I/Q interface of other Rohde & Schwarz instruments (e.g. R&S®AMU200A, R&S®EX-IQ-BOX).

DIG I/Q IN/OUT 1/3 input and output, bidirectional, half duplex 26-pin MDR connector Level LVDS Clock rate in 100 MHz Clock rate out 100 MHz

DIG I/Q OUT 2/4 output 26-pin MDR connector Level LVDS Clock rate 100 MHz

Control signals general-purpose control, for future use 6 signals 100 MHz

I/Q data Resolution for clock rate up to 100 MHz 16 bit for I and 16 bit for Q

I/Q sample rate Source internal, digital input, digital output,

AUX interface Range 1.92 MHz to 100 MHz

standard-independent 100 MHz Predefined values 19 WCDMA, LTE 1.92 MHz, 3.84 MHz, 7.68 MHz,

15.36 MHz, 30.72 MHz

I/Q enable/request rate I/Q mode 1 75 MHz, 100 MHz Digital input I/Q mode 2 0 MHz to 100 MHz I/Q mode 1 75 MHz, 100 MHz I/Q mode 2 0 MHz to 100 MHz

Digital output

I/Q mode 4 75 MHz

AUX interface The AUX interface can be used for connecting the R&S®CMW to other instruments, e.g. to trigger, clock and enable signals.

AUX A/B bidirectional, half duplex two BNC connectors Level 3.3 V TTL Clock rate 0 MHz to 100 MHz

Included extras Digital I/Q cable (two sets) same cable as included in R&S®SMU-Z6 26-pin MDR connector

18 R&S®CMW500 only. 19 Further values in range of 400 Hz to 100 MHz can be provided on demand.

Page 30: R&S®CMW500 Test & Measurement Data Sheet | 05.00 … · Wideband Radio Communication Tester Specifications ... WCDMA specifications ... except fnonharmonic = 3900 MHz

30 R&S®CMW500 Wideband Radio Communication Tester Version 05.00, November 2008

General data RF connectors (front panel) Snap-N female, 50 Ω, compatible with

N female connectors RF1 COM, RF2 COM combined RF input and RF output RF1 OUT RF output

Remote control interfaces (front panel) 20

LAN Ethernet RJ-45 connector, 100 Mbit/s

Remote control interfaces (rear panel) R&S®CMW-B612A IEEE bus (single) interface option or

IEC 60625-2 (IEEE 488.2), 24-pin Amphenol connector

IEEE 488

R&S®CMW-B612B IEEE bus (dual) interface option 20

2 × IEC 60625-2 (IEEE 488.2), 24-pin Amphenol connector

LAN REMOTE Ethernet RJ-45 connector, 1000 Mbit/s USB REMOTE 20 USB 2.0 type B connector

Further interfaces (front panel) USB for keyboard, mouse, USB stick 3 × USB 2.0 type A connector SENSOR for R&S®NRP-Zxx power sensors DIGITAL MONITOR for external monitor,

only included in R&S®CMW-S600A or R&S®CMW-S600E configuration (front panel without display or keypad)

DVI-D connector

Further interfaces (rear panel) 1 × USB 2.0 type A connector USB for keyboard, mouse, USB stick 1 × USB 1.1 type A connector

DVI for external monitor, R&S®CMW-B620A DVI interface option

DVI-D connector

trigger input/output 2 × BNC connector TRIG A, TRIG B output trigger sources GPRF: BB generator,

WCDMA: DCCH TTI trigger, WCDMA: frame trigger, WCDMA: HS-DPCCH trigger, WCDMA: slot trigger, WCDMA: TPC trigger

Operating temperature range +5 °C to +45 °C, in line with EN 60068-2-1 and -2

Storage temperature range –25 °C to +60 °C, in line with EN 60068-2-1 and -2

Humidity +40 °C, non-condensing 80 % relative humidity, in line with EN 60068-2-78

Electromagnetic compatibility The instrument complies with the emission requirements stipulated by EN 55011 class A. This means that the instrument is suitable for use in industrial environments.

in line with EMC Directive 2004/108/EC, applied standard: EN 61326 (immunity: for industrial environment; emissions: class A)

Electrical safety in line with IEC 61010-1: 2001 (ed. 2), EN 61010-1: 2001 (ed. 2), UL61010-1 (ed. 2), CAN C22.2 No. 61010-1-04

20 R&S®CMW500 only.

Page 31: R&S®CMW500 Test & Measurement Data Sheet | 05.00 … · Wideband Radio Communication Tester Specifications ... WCDMA specifications ... except fnonharmonic = 3900 MHz

Version 05.00, November 2008 R&S®CMW500 Wideband Radio Communication Tester 31

Mechanical resistance non-operating mode Vibration sinusoidal in line with EN 60068-2-6,

MIL-PRF-28800F class 3 and 4, 5 Hz to 150 Hz, max. 2 g at 55 Hz, 55 Hz to 150 Hz, 0.5 g const.

Vibration random in line with EN 60068-2-64, 10 Hz to 300 Hz, acceleration 1.2 g rms

Shock in line with MIL-STD-810F 40 g shock spectrum

Power supply power factor correction, in line with EN 61000-3-2

Input 100 V to 240 V ±10 % (AC), max. 850 VA, 50 Hz to 60 Hz ±5 %

R&S®CMW500 single tester, non-signaling approx. 200 W Power consumption R&S®CMW280 single tester, non-signaling approx. 180 W

Display selected with R&S®CMW-S600B or R&S®CMW-S600F configuration (front panel with display and keypad)

21 cm TFT color display (8.4”)

Resolution 800 × 600 pixels (SVGA resolution) Pixel failure rate <1.1 × 10–5

W × H × D, overall 465.1 mm × 197.3 mm × 517.0 mm 18.31 in × 7.77 in × 20.35 in

Dimensions R&S®CMW500

for rackmounting 19” 1/1, 4 HU, 450 W × H × D, overall 465.1 mm × 197.3 mm × 417.0 mm

18.31 in × 7.77 in × 16.41 in Dimensions R&S®CMW280

for rackmounting 19” 1/1, 4 HU, 350 single tester, non-signaling approx. 14 kg

approx. 31 lb Weight R&S®CMW500

with typical options approx. 18 kg approx. 40 lb

single tester, non-signaling approx. 12 kg approx. 27 lb

Weight R&S®CMW280

with typical options approx. 14 kg approx. 31 lb

12 months recommended for highest accuracy, see specified RF generator and RF analyzer level uncertainty

Calibration interval

24 months add 0.2 dB to specified RF generator and RF analyzer level uncertainty

Page 32: R&S®CMW500 Test & Measurement Data Sheet | 05.00 … · Wideband Radio Communication Tester Specifications ... WCDMA specifications ... except fnonharmonic = 3900 MHz

32 R&S®CMW500 Wideband Radio Communication Tester Version 05.00, November 2008

Ordering information Designation Type Order No. Wideband Radio Communication Tester Base Unit with following accessories: power cord, operating manual (quick start guide), comprehensive documentation on CD-ROM

R&S®CMW500 1201.0002K50

Wideband Radio Communication Tester Base Unit with following accessories: power cord, operating manual (quick start guide), comprehensive documentation on CD-ROM

R&S®CMW280 1201.0002K25

For more ordering information about available options, please see our product brochure (PD 5213.9211.12) or ask your local Rohde & Schwarz expert to find the solution that is optimally suited to your needs.

Page 33: R&S®CMW500 Test & Measurement Data Sheet | 05.00 … · Wideband Radio Communication Tester Specifications ... WCDMA specifications ... except fnonharmonic = 3900 MHz

Version 05.00, November 2008 R&S®CMW500 Wideband Radio Communication Tester 33

Recommended extras for manual operation For R&S®CMW-S600B configuration (front panel with display and keypad):

Designation Type Order No. Mouse with USB interface, optical R&S®PSL-Z10 1157.7060.04

For R&S®CMW-S600A configuration (front panel without display or keypad):

Designation Type Order No. Mouse with USB interface, optical R&S®PSL-Z10 1157.7060.04 Keyboard with USB interface (US assignment) R&S®PSL-Z2 1157.6870.04 17" TFT monitor R&S®PMC3 1082.6004.12

Important information: We recommend using only the above-mentioned original PC components from Rohde & Schwarz in connection with the R&S®CMW500 and R&S®CMW280. The interaction of all components is continuously tested. Insufficiently shielded PC components may lead to EMC problems which may disturb RF measurements results.

Recommended extras Designation Type Order No. 19” Rack Adapter R&S®ZZA-411 1096.3283.00 Digital Signal Interface Module R&S®EX-IQ-BOX 21 1409.5505.02 Cable TVR 290, 26-pin MDR Connector; additional cable for R&S®CMW-B510A used with e.g. R&S®AMU200A, R&S®EX-IQ-BOX

R&S®SMU-Z6 21 1415.0201.02

21 R&S®CMW500 only.

Page 34: R&S®CMW500 Test & Measurement Data Sheet | 05.00 … · Wideband Radio Communication Tester Specifications ... WCDMA specifications ... except fnonharmonic = 3900 MHz

Certified Environmental System

ISO 14001DQS REG. NO 1954 UM

Certified Quality System

ISO 9001DQS REG. NO 1954 QM

For product brochure, see PD 5213.9211.12

and www.rohde-schwarz.com

Rohde & Schwarz GmbH & Co. KGMühldorfstraße 15 | 81671 MünchenPhone +49 89 41 290 | Fax +49 89 41 29 121 64

www.rohde-schwarz.com

R&S® is a registered trademark of Rohde & Schwarz GmbH & Co. KG Trade names are trademarks of the owners | Printed in Germany (as) PD 5213.9211.22 | Version 05.00 | November 2008 | R&S®CMW500 Subject to change *0.14 €/min within German wireline network; rates may vary in other networks (wireline and mobile) and countries.

Service you can rely onJ In 70 countries J Person-to-personJ CustomizedandflexibleJ Quality with a warrantyJ No hidden terms

About Rohde & SchwarzRohde & Schwarz is an independent group of companies specializing in electronics. It is a leading supplier of solu-tions in the fields of test and measurement, broadcasting, radiomonitoring and radiolocation, as well as secure com-munications. Established 75 years ago, Rohde & Schwarz has a global presence and a dedicated service network in over 70 countries. Company headquarters are in Munich, Germany.

Regional contactEurope, Africa, Middle East+49 1805 12 42 42* or +49 89 4129 137 [email protected] America1 888 TEST RSA (1 888 837 87 72)[email protected] America+1 410 910 79 [email protected]/Pacific+65 65 13 04 [email protected]

Rohde & Schwarz GmbH & Co. KGMühldorfstraße 15 | 81671 MünchenPhone +49 89 41 290 | Fax +49 89 41 29 121 64

www.rohde-schwarz.com

R&S® is a registered trademark of Rohde & Schwarz GmbH & Co. KG Trade names are trademarks of the owners | Printed in Germany (as) PD 5213.9211.22 | Version 05.00 | November 2008 | R&S®CMW500 Subject to change *0.14 €/min within German wireline network; rates may vary in other networks (wireline and mobile) and countries.

Titel + Rück_CMW500.indd 2 25.11.2008 18:05:23