RS422/BBV Coax Telemetry Interface 16 channel Installation manuals_Folder/Index folder/CTI 16... ·...

20
Building Block Video Ltd., 17 Apex Park, Diplocks Industrial Estate, Hailsham, East Sussex, BN27 3JU UK. Tel: +44(0)1323 842727 Fax: +44(0)1323 842728 Support: +44(0)1323 444600 www.bbvcctv.com CTI/16 RS422/BBV Coax Telemetry Interface 16 channel Building Block Video Ltd 17 Apex Park Diplocks Industrial Estate Hailsham, East Sussex, BN27 3JU, UK Tel: + 44 (0) 1323 842727 Fax: + 44 (0) 1323 842728 Support: + 44 (0) 1323 444600 www.bbvcctv.com Installation Guide

Transcript of RS422/BBV Coax Telemetry Interface 16 channel Installation manuals_Folder/Index folder/CTI 16... ·...

Building Block Video Ltd.,

17 Apex Park,

Diplocks Industrial Estate,

Hailsham, East Sussex, BN27 3JU UK.

Tel: +44(0)1323 842727

Fax: +44(0)1323 842728

Support: +44(0)1323 444600 www.bbvcctv.com

CTI/16 RS422/BBV Coax Telemetry Interface 16 channel

Building Block Video Ltd

17 Apex Park

Diplocks Industrial Estate

Hailsham, East Sussex, BN27 3JU, UK

Tel: + 44 (0) 1323 842727

Fax: + 44 (0) 1323 842728

Support: + 44 (0) 1323 444600 www.bbvcctv.com

Installation Guide

CTI16 Manual V15.4 April 2014 Page 3/20

Contents

Pre-installation checks & safety procedures 4 Introduction 5 Unpacking 5 Technical Specification 6 CTI/16 & CTI/8 Software version history 6 Test Mode 7 Setting the protocol & baud rate 8 Address setting 9 Advanced features table 10 CTI/16 Connection details 11 Diagnostic LEDs 12 Intellex DVR controlling domes up the coax via CTI/16 telemetry interface 13 DVX to CTI/16 driving RX100/VCL 14 Vicon matrix controlling CTI/16 with 360 Vision domes 15 2060 Dennard domes with up the coax control & 4 local alarms 16 Philips Bi-Phase matrix to CTI/16 driving an RX55X 17

CTI16 Manual V15.4 April 2014 Page 4/20

PRE-INSTALLATION CHECKS AND SAFETY PROCEDURES

Unpacking - Inspect the packaging for signs of damage. If damage has occurred, advise the carrier and/or the suppliers immediately. Unpack the receiver carefully and check that all the items are present and correct (see checklist on box). If any item is missing contact the supplier.

Retain packaging - The shipping carton is the safest container in which to transport the unit. Retain undamaged packaging for possible future use.

IMPORTANT SAFETY PRECAUTIONS

Read & retain instructions - All relevant safety, installation and operating instructions should be read & retained before attempting to install, connect or operate the unit.

Water and moisture - Do not expose the internal electronics of this unit to water or dampness.

Power sources - This unit should be operated only from the supplied power supply.

Servicing - Servicing of the unit should only be undertaken by qualified service personnel.

Damage requiring service - Servicing by qualified personnel should be carried out under the following conditions:

(a) When the power supply cord or plug is damaged; (b) If liquid has been spilled, or objects have fallen into, the unit; (c) If the internal electronics of the unit have been exposed to rain or water; (d) If the unit does not operate normally by following the operating instructions. (e) If the unit has been dropped or the enclosure is damaged;

Replacement parts - If replacement parts are required, ensure that only replacement parts recommended by the product manufacturer are used.

Safety check - Upon completion of any service or repairs to the unit, safety checks should be performed to ensure that the unit is in proper operating condition.

Coax grounding - If an outside cable system is connected to the unit, be sure the cable system is grounded.

Pre-installation checks - It is recommended that the unit be bench-tested prior to installation on the site.

Adhere to Safety Standards - All normal safety precautions as laid down by British Standards and the Health and Safety at Work Act should be observed.

WARNING TO PREVENT DANGER OF FIRE OR SHOCK, DO NOT EXPOSE THE INTERNAL COMPONENTS OF THIS EQUIPMENT TO RAIN OR MOISTURE.

CTI16 Manual V15.4 April 2014 Page 5/20

INTRODUCTION

GENERAL The CTI/16 is designed to provide conversion from RS422/485 data to BBV Coax Telemetry based systems. Up the Coax telemetry allows upgrading of static cameras to PTZ without the need for additional cabling. One RS422/485 input that is dipswitch selectable. The Baud Rates & Parity for Pelco P/D & Vicon Protocols are variable. Sixteen individual outputs are provided. Each output connects to a single receiver. Each unit is supplied with a break out box and 0.5mtr Cat 6 patch cable. Multiple CTI/16 can be cascaded together giving up to 256 camera outputs.

Please Note: Camera address will be limited to the maximum number supported by the individual

protocol.

Please note: Menu Access commands of cameras can vary between control equipment even if using

the same protocol.

For Example: In Pelco D protocol - dome menu access commands can be either Goto Preset 95 or

Save Preset 95. Enter = Goto Preset 1 or Iris Open / Close Protocols currently supported are:

BBV,

Pelco P/D,

Pelco P DM,

VCL,

Dennard,

Philips,

Sensormatic RS422,

Molynx,

Vicon. The CTI/16 has been tested with the BBV FBM/256 Matrix & Starcard Converter, BBV TX1500/96 Matrix & Starcard Converter, Pelco KBD300, DM DS2, VCL VCTM16 Matrix & Maxcom 8 Matrix & Keyboard, Philips Allegiant 32 Camera Matrix LTC8301/50 & Bi – Phase to RS232 Converter LTC8780/50, American Dynamics Intellex LT V4 Software, Molynx TTX600 Keyboard & TTX6164T Matrix and Vicon VI411-DVC Keyboard

Unpacking

Inspect the packaging for signs of damage. If damage has occurred, advise the carriers and/or the suppliers immediately. Unpack the interface carefully and check all the items are included:

CTI/16 RS422/BBV Coax Telemetry Interface 16 channel X

CAT6 patch cable X

Break out box X

Mounting brackets X

9 to 12Vdc PSU X

Manual X

CTI16 Manual V15.4 April 2014 Page 6/20

Technical Specification

Power Requirements 9 to 12Vdc PSU 500mA

Inputs 2 Wire RS485, 2 Wire RS422 Simplex and 4 Wire Full Duplex (switch selectable input protocol) Maximum Cable Distance Belden 8723 = 1200m

Outputs 16 x BBV Coax Telemetry Maximum Cable Distance RG59 = 250m CT125 = 500m

Supported Protocols

Facilities LED as power indication

Boxed Dimensions Supplied in 19” 1 U rack mountable case Length 425mm

Depth 110mm Height 43mm

Installation The unit is designed to either be fitted into a 19” rack or wall mounted via the fixing brackets supplied

CTI/16 Manual & Software Version History Version 15.4 April 2014 -1. Updated layout to Protocols pages 5&6 -2. Visio drawings updated from Rx100 to Rx10X Version 15.2 June 2010 -1. Change to the Test mode page Version 15A June 2010 -1. Change to the Sensormatic commands on page 9 Version 15 11 December 2009 -1. Added Test feature. Pan Left & Right via dipswitches Version 1 8 May 2008 - 1. CTI/8 Released Version 13 15 October 2007 -1. Bug fix for address 27 in Dennard RS485 Protocol Version 12 10 October 2007 -1. Bug fix for address 2 & 3 in Dennard RS485 Protocol Version 11 3 September 2007 -1. Updated Support of VCL Telemetry from Maxcom 8 Matrix -2. Manual Update Version 10 15 August 2007 -1. Bug fix of VCL Telemetry from Maxcom 8 Matrix Version 9 10 July 2007 -1. Updated Support of VCL Telemetry from Maxcom 8 Matrix Version 8 17 March 2007 -1. Updated support of Hash Command release time

-2. Manual update. Version 7 13 February 2007 -1. Added continuous sending of telemetry for legacy coax receivers Version 6 8 January 2007 - 1. Molynx Protocol Speed table recalibration Version 5 11 December 2006 - 1. Bug fix for Accumulative Delays in Pelco P & D and Dennard RS485 Routines

- 2. Updated watchdog routine - 3. Added support for Sensormatic RS422 Protocol - 4. Added support for Molynx RS485 Protocol - 5. Added support for Vicon RS485 Protocol variable Baud Rate

Version 4 18 November 2005 - 1. Added support for Pelco P/D Protocol variable Baud Rate & Parity settings. - 2. Added support for Pelco P DM Auxiliary outputs.

Version 3 27 June 2005 - 1. Added support for Dennard 2050 Protocol. Version 2 25 May 2005 - 1. Added support for Philips RS485 Protocol. Version 1 11 November 2005 - 1. CTI/16 Released

Support of BBV, Dennard, Philips, Pelco P & D and VCL RS485 input protocols converting to BBV Coax output protocol.

BBV422 9600

Pelco P 2400, 4800 & 9600

Pelco P DM 2400, 4800 & 9600

Pelco D 2400, 4800 & 9600

VCL 9600

Dennard 9600

Philips 9600

Sensormatic 4800

Molynx 9600

Vicon 4800, 9600, 19200

CTI16 Manual V15.4 April 2014 Page 7/20

7 81 2 3 54 6

ON

7 81 2 3 54 6

ON

SW1 Cam 1 Pan Left SW1 Cam 2 Pan Left

7 81 2 3 54 6

ON

7 81 2 3 54 6

ON

7 81 2 3 54 6

ON

7 81 2 3 54 6

ON

7 81 2 3 54 6

ON

This feature enables the Camera to be driven left or right from the Coax Telemetry Interface directly

7 81 2 3 54 6

ON

7 81 2 3 54 6

ON

7 81 2 3 54 6

ON

7 81 2 3 54 6

ON

7 81 2 3 54 6

ON

7 81 2 3 54 6

ON

7 81 2 3 54 6

ON

7 81 2 3 54 6

ON

SW2 Sets Test Mode SW1 Sets Camera Number &

Direction

SW1 Cam 3 Pan Left

SW1 Cam 4 Pan Left SW1 Cam 5 Pan Left SW1 Cam 6 Pan Left

SW1 Cam 7 Pan Left SW1 Cam 8 Pan Left SW1 Cam 9 Pan Left

SW1 Cam 10 Pan Left SW1 Cam 11 Pan Left SW1 Cam 12 Pan Left

SW1 Cam 13 Pan Left SW1 Cam 14 Pan Left SW1 Cam 15 Pan Left

SW1 Cam 16 Pan Left

7 ON = Pan Left

8 ON = Pan Right

7 81 2 3 54 6

ON

75 7 81 2 3 54 6

ON

7 81 2 3 54 6

ON

Test Mode

CTI16 Manual V15.4 April 2014 Page 8/20

Setting the Protocol and baud rate

Input Termination

7 81 2 3 54 6

ON

7 81 2 3 54 6

ON

SW2 BBV 9600 N 8 1 SW2 Pelco P 9600 N 8 1

7 81 2 3 54 6

ON

7 81 2 3 54 6

ON

7 81 2 3 54 6

ON

7 81 2 3 54 6

ON

7 81 2 3 54 6

ON

The CTI/16 will only output BBV Coax Telemetry on the 16 Coax output channels

The CTI/16 supports various RS422/485 input Protocols

7 81 2 3 54 6

ON

7 81 2 3 54 6

ON

7 81 2 3 54 6

ON

7 81 2 3 54 6

ON

7 81 2 3 54 6

ON

7 81 2 3 54 6

ON

7 81 2 3 54 6

ON

7 81 2 3 54 6

ON

SW2 Sets Protocol & Baud Rate SW1 Sets Address & Parity

SW2 Pelco P 4800 N 8 1

SW2 Pelco P 2400 N 8 1 SW2 Pelco P DM 9600 N 8 1 SW2 Pelco P DM 4800 N 8 1

SW2 Pelco P DM 2400 N 8 1 SW2 Pelco D 9600 N 8 1 SW2 Pelco D 4800 N 8 1

SW2 Pelco D 2400 N 8 1 SW2 VCL 9600 N 8 1 SW2 Dennard 9600 N 8 1

SW2 Philips 9600 N 8 1

7 81 2 3 54 6

ON

75

SW2 Sensormatic 4800 N 8 2

7 81 2 3 54 6

ON

7 81 2 3 54 6

ON

7 81 2 3 54 6

ON

7 81 2 3 54 6

ON

SW2 Molynx 9600 E 8 1

SW2 Vicon 19200 N 8 1 SW2 Vicon 9600 N 8 1 SW2 Vicon 4800 N 8 1

7 & 8 OFF = None Parity

7 & 8 ON = Odd Parity

7 OFF & 8 ON = Even Parity

CTI16 Manual V15.4 April 2014 Page 9/20

7 81 2 3 54 6

ON

7 81 2 3 54 6

ON

7 81 2 3 54 6

ON

7 81 2 3 54 6

ON

7 81 2 3 54 6

ON

7 81 2 3 54 6

ON

7 81 2 3 54 6

ON

7 81 2 3 54 6

ON

7 81 2 3 54 6

ON

7 81 2 3 54 6

ON

7 81 2 3 54 6

ON

7 81 2 3 54 6

ON

7 81 2 3 54 6

ON

7 81 2 3 54 6

ON

7 81 2 3 54 6

ON

7 81 2 3 54 6

ON

SW1 Sets Address

Address Settings

The CTI/16 supports a maximum of 256 addresses

A maximum of 16 x CTI/16 can be cascaded togetherN.B. Refer to input Protocol documents for maximum address supported

i.e. Pelco P max addr = 32

Address Range 1 - 16

Address Range 17 - 32 Address Range 33 - 48 Address Range 49 - 64

Address Range 65 - 80 Address Range 81 - 96 Address Range 97 - 112

Address Range 113 - 128 Address Range 129 - 144 Address Range 145 - 160

Address Range 161 - 176 Address Range 177 - 192 Address Range 193 - 208

Address Range 209 - 224 Address Range 225 - 241 Address Range 242 - 256

CTI16 Manual V15.4 April 2014 Page 10/20

Advanced Features Table

BBV COAX OUTPUT

1# 2# 3# 4# START 1 PATROL

START 2 PATROL

START AUTOPAN

BBV Tx1500

1# 2# 3# 4# 1 PATROL 2 PATROL

AUTOPAN

PELCO SAVE PRESET 95

OR GOTO PRESET 61

GOTO PRESET 33 OR GOTO PRESET 62

GOTO PRESET 94 OR

GOTO PRESET 63 GOTO PRESET 64

GOTO PRESET 66

GOTO PRESET 67

GOTO PRESET 68

VCL GOTO PRESET 95

OR GOTO PRESET 61

GOTO PRESET 62 GOTO PRESET 63 GOTO PRESET 64 GOTO

PRESET 66 GOTO

PRESET 67 GOTO PRESET

67

DENNARD SAVE PRESET 95

OR GOTO PRESET 61

GOTO PRESET 33 OR GOTO PRESET 62

GOTO PRESET 94 OR

GOTO PRESET 63 GOTO PRESET 64

GOTO PRESET 66

GOTO PRESET 67

GOTO PRESET 67

PHILIPS AUX 46 ON

OR GOTO PRESET 61

AUX 63 ON OR

GOTO PRESET 62

AUX 100 ON/OFF OR

GOTO PRESET 63

SET 899 OR

GOTO PRESET 64

GOTO PRESET 66

GOTO PRESET 67

GOTO PRESET 67

SENSORMATIC

START PATTERN 3 REPEATED 5 TIMES

FOLLOWED BY SAVE PRESET 1

OR GOTO PRESET 61

SEE note 1

START PATTERN 3 REPEATED 5 TIMES

FOLLOWED BY SAVE PRESET 1

OR GOTO PRESET 62

SEE note 1

START PATTERN 3 REPEATED 5 TIMES

FOLLOWED BY SAVE PRESET 1

OR GOTO PRESET 63

SEE note 1

START PATTERN 3 REPEATED 5 TIMES

FOLLOWED BY SAVE PRESET 2

OR GOTO PRESET 64

SEE note 1

GOTO PRESET 71

GOTO PRESET 72

GOTO PRESET 73

MOLYNX AUX 1

OR GOTO PRESET 61

AUX 2 OR

GOTO PRESET 62

HOME OR

GOTO PRESET 63

CAMERA On/Off OR

GOTO PRESET 64

GOTO PRESET 66

GOTO PRESET 67

GOTO PRESET 67

VICON

SAVE PRESET 94 OR 95

OR GOTO PRESET 61

GOTO PRESET 62 GOTO PRESET 63 GOTO PRESET 64 GOTO

PRESET 66 GOTO

PRESET 67 GOTO PRESET

67

NOTE1. 5min time out / Goto Preset 6 to Cancel

When using BBV422 & Pelco P you can toggle wash, wipe & lights with Goto Preset commands:

Preset 81 Wash on, Preset 82 Wash off, Preset 83 Wipe on, Preset 84 Wipe off, Preset 85 Lights on & Preset 86 Lights off.

CTI16 Manual V15.4 April 2014 Page 11/20

CTI/16 Connection Details The CTI/16 unit is supplied with a Cat 6 Patch cable and a Break Out Box.

RED

BLACK

ORANGE

GREEN

YELLOW

BROWN

WHITE

1 =NC(CAT5) WHITE/ORANGE

2 =NC(CAT5) ORANGE

3 = RXA (TO Controller)(CAT5) WHITE/GREEN

4 = TXA (FROM Controller)(CAT5) BLUE

TXB (FROM Controller) = 5(CAT5) WHITE/BLUE

RXB (TO Controller) = 6(CAT5) GREEN

Gnd = 7(CAT5) WHITE/BROWN

Gnd = 8(CAT5) BROWN

RJ45 Surface Socket

FARNELL No 454-485

BLUE

Connection information

TXA (FROM Controller) DATA + from the DVR/ MATRIX to CTI16

TXB (FROM Controller) DATA - from the DVR/ MATRIX to CTI16

RXA (TO Controller) DATA + to the DVR/ MATRIX from CTI16

RXB (TO Controller) DATA - to the DVR/ MATRIX from CTI16

see RS422 NOTE

RS422 NOTE Some systems require RS422 FULL DUPLEX before they will work. Some Sensormatic systems require a 4 Wire connection.

CTI16 Manual V15.4 April 2014 Page 12/20

Diagnostic LEDs

02008 iss 3

Bit 7 Tx Termination

Bit 8 Rx TerminationBBVJ9

LD1 LD2 LD3 LD4 LD5 LD6 LD7 LD8

LD10

J19

12345678

ON

12345678

ON

SW1SW2

12345678

ON

12345678

ON

SW1SW2

SW2 BBV422 SW1 Address Range 1 - 16

LD10

LD 1-8

If there are no video sources you will see

LD1 to 8 flash in sequence.

When a video source is applied to either

input the associated LED will be on

constantly.

LD 10

LD10 will flash when the CTI/16 is

sending data to the coax driver chips,

even if there are no video sources. This

is a good way to test if the CTI/16 is

connected and configured correctly.

RS

422/485 PO

RT

PO

WE

R LE

D

PO

WE

R IN

PU

T 9 - 12 D

C 500m

A

CTI16 Manual V15.4 April 2014 Page 13/20

BBV Intellex Kit

CTI16

16 Camera Coax

Telemetry Interface

RG59 <250M

CT125 <500M

Coax from DomeRS485 to Dome

Edgeport/1

USB Converter

R

XL

OH

IT

X

Rx10X Per Dome

Please note this is a small selection of the domes that can be controlled by the

BBV Rx10X . For a full list of dome please refer to the BBV website

www.bbvcctv.com. It is important that the Rx10X must be close to the dome

within 5 meter is recommended. The CTI Card can control the full range of

BBV Coax Receivers

Rx200

AC output, Wash, Wipe, Lights for static cameras

Rx300

AC output, Pan/Tilt/Zoom/Focus + choice of Wash, Wipe, Lights or Autopan,

Random Pan.

Rx400P

AC output, Pan/Tilt/Zoom/Focus/Iris, Wash, Wipe, Lights, Autopan, 16 presets,

Preset patrol

Rx45X

Advanced Telemetry Receiver – fixed speed AC P/T head. 16 presets, 8 alarm

inputs, OSD programming menu. Remote gain control. Selectable between

230Vac or 110Vac supply. 12Vdc 500mA camera supply output. Links

selectable mains or 24Vac output. Wash, Wipe, Lights and Autopan outputs.

Rx55X

As Rx45X to drive 24Vdc high/variable speed P/T head. Wash, Wipe and

Lights outputs.

LG Domes

JVC

TX_C676 Pelco Domes Pelco Esprit Bosch Domes

Panasonic

Vicon

Surveyor

Sensormatic

VCL

Honeywell

CBC C-All

View

Dennard

Domes

CBC C-ViewVIDECON

Borsatec

BT2790FF

Vista

Powerdome

Samsung

CTI16 Manual V15.4 April 2014 Page 14/20

CTI/16

Pelco D 2400 N 8 1 RS422 Simplex

OR

Pelco D 2400 E 8 1 RS422 Simplex

DVX

DVX to CTI/16 driving Rx10X

Rx10X

LAN

IP SWITCH

LAN

Coax

Tw

iste

d P

air R

S4

22

Sim

ple

x

Max Distance Coax

RG59=250mtrs

CT125=500mtrs

VCL Dome

Rx10X to

Dome Max

Distance 5mtrs

PC with DVX Viwer

CTI16 Manual V15.4 April 2014 Page 15/20

VICON KEYBOARD NETWORK

COAX

VICON SIMPLEX

Coax Distance 250M RG59 500M CT125

VICON MATRIX CONTROLLING CTI16 WITH 360 VISION DOMES

CTI16 Manual V15.4 April 2014 Page 16/20

CTI16

control to

Domes

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 B-BUS PORT

BBV SUPPLY ONLY

9VDC 500mA MAX

Rx10X/WBX

25

0M

RG

59

/ 5

00

M C

T1

25

RS422

LTC8780/50

RS232 kit

BiPHASE

2060 Dennard Domes with up the coax control and 4 local alarms

CTI16 Manual V15.4 April 2014 Page 17/20

Rx55X Multiple

protocol telemetry

receiver

R

XT

X

RS

23

2

CTI/16

Philips Bi-Phase Matrix

Philips Kbd

CoaxPhilips G3 Dome

Bi-Phase

Bi-Phase

Philips Bi-Phase Matrix to CTI/16 driving Rx55X

Coax

RS232 kit

Coax

Max Distance Coax

RG59=250m

CT125=500m

RS

42

2 S

IMP

LE

X

CTI16 Manual V15.4 April 2014 Page 18/20

Up to 250m RG59

Up to 500m CT125

Control Location

CAMERAS

7654321 8 1

MONITOR

ALARM INPUTS

KBD1RS23212V DCTWISTED

PAIR

13 12

12

11 10 9 8 7 6

25 24 23 22 21 20 19 18 17 16 15 14

5 4 3 2 1

MAXCOM8VCL

P A 7020C

20" C o lo r M on ito r

B DATA - n

B DATA + n

BBV CTI/16

BBV Rx10XBBV VA1

Pins Facing away from

you

NOT USED

NOT USED

NOT USED

DATA + DATA -

NOT USED

GND

GREENRED

YELLOWBLACK

ORANGE

BLUE WHITE

BROWN

X DATA - n

X DATA + n

GN

D.

Twisted Pair Plug

Camera Location

GND

CTI16 Manual V15.4 April 2014 Page 19/20

CTI16 Manual V15.4 April 2014 Page 20/20

Extend your BBV Warranty from 12 months to 3 years

As of the 1st September 2008 BBV have offered our

customers the opportunity to extend the standard 12 month warranty to 3 years. You must register for the extended warranty within 12 months of the date of manufacture.

How to register for the 3 year warranty

Or alternatively: Register online at: www.bbvcctv.com Simply enter your details on the ‘Warranty Cover’ page.

Registering for the new, longer 3 year warranty term is quick and easy. Either: Complete the warranty application card that comes in the box with your BBV product, and return it FREEPOST to BBV:

VAT Reg. No. 621758439 Registered in England No. 2852921 Registered office: 17 Apex Park Diplocks Way Hailsham East Sussex UK BN27 3JU

If this card is returned with the serial number of the product and the Installation company

details BBV will extend the warranty period from 12 Months to 36 Months.

I do not require any other further product information,

BBV 3 Year Warranty

Please could you send me information

especially on:

Rx100s

Rx45x & Rx55x

FBM Video Matrices

Tx1500 Video Matrices

Starcard & Starcard Converters

BBV Quad

Pick A Point

Please refer to WWW.BBVCCTV.COM for terms, conditions & exclusions

Contact Name.

Company Name.

Phone Number.

Site Name.

Address 1.

Address 2.

Address 3.

e-mail address.

Post Code.

Do you read.

Number of Units, Start Serial No. Final Serial No.