2
POWER CAPACITOR ● Maximum voltage 20.70kV. ● Maximum output 750kVAr (Single Phase) ● All Polypropylene (APP) film dielectric. ● Ultra low losses. ● Indoor or Outdoor application up to 95kV BIL. ● Superior electrical performance. Improved tank rupture characteristics. POLE MOUNTED CAPACITOR BANK ● It consists of Procap make Controller solid Dielectric Vacuum Switch, Current Sensor having high Dielectric Strength, Potential Transformer & Power Capacitor Units. ● Available at 15kV, 25kV & 35kV application ● Suitable for outdoor application ● Less space required ● Auto or Manual operated Power Factor Correction System. ● Application: Agriculture Load, Induction Furnance, Distribution Transformer and Heavy Industrial Load OPEN RACK SUBSTATION BANK ● Shunt Compensation ● Capacitors available in internal and external fuse protection ● Range: Maximum Power : 60MVAR or more System Voltage : 11kV-230kV Capacitor : APP Film Type M.V. PAD MOUNTED CAPACITOR BANK ● Shunt Compensation (Fixed and Automatic) ● Capacitors available in external fuse protection ● Range: Maximum Power : 9MVAR System Voltage : 6kV-11kV Capacitor : APP Film Type Outdoor PT up to 72 KV Outdoor CT up to 72 KV Indoor PT up to 36 KV Indoor CT up 36 kV Cast Resin Material ISO 9001:2008

description

RPV Electro Technology Philippines Corporation Core 6 Leaflet which is for Medium Voltage Equipment & Devices.

Transcript of RPV Medium Voltage Equipment & Devices

Page 1: RPV Medium Voltage Equipment & Devices

POWER CAPACITOR

● Maximum voltage 20.70kV. ● Maximum output 750kVAr (Single Phase) ● All Polypropylene (APP) film dielectric. ● Ultra low losses. ● Indoor or Outdoor application up to 95kV BIL. ● Superior electrical performance. Improved tank rupture characteristics.

POLE MOUNTED CAPACITOR BANK

● It consists of Procap make Controller solid Dielectric Vacuum Switch, Current Sensor having high Dielectric Strength, Potential Transformer & Power Capacitor Units. ● Available at 15kV, 25kV & 35kV application ● Suitable for outdoor application ● Less space required ● Auto or Manual operated Power Factor Correction System. ● Application: Agriculture Load, Induction Furnance, Distribution Transformer and Heavy Industrial Load

OPEN RACK SUBSTATION BANK

● Shunt Compensation ● Capacitors available in internal and external fuse protection ● Range: Maximum Power : 60MVAR or more System Voltage : 11kV-230kV Capacitor : APP Film Type

M.V. PAD MOUNTED CAPACITOR BANK

● Shunt Compensation (Fixed and Automatic) ● Capacitors available in external fuse protection ● Range: Maximum Power : 9MVAR System Voltage : 6kV-11kV Capacitor : APP Film Type

Outdoor PT up to 72 KV Outdoor CT up to 72 KV

Indoor PT up to 36 KV Indoor CT up 36 kV

Cast

Res

in

Mate

rial

ISO

90

01:2

00

8

Page 2: RPV Medium Voltage Equipment & Devices

POLE MOUNTED CAPACITY : 10-333kVA VOLTAGE : up to 36kV

PAD MOUNTED CAPACITY : 100-5,000kVA VOLTAGE : up to 36kV

OIL IMMERSED CAPACITY : 25-1,000kVA VOLTAGE : up to 36kV

POWER TRANSFORMER CAPACITY : 1MVA-30MVA VOLTAGE : up to 72kV

CAST RESIN CAPACITY : 100-15,000kVA VOLTAGE : up to 36kV

ISO 9001 - 2008

ISO 14001 Type Test Report for Oil Type Transformer

Type Test Report for Cast Resin Transformer

Also manufactured Amorphous Type Transformer

Vacuum Circuit Breakers

• Rated breaking time of all types - 3 cycle • Nuclear power certification ANSI C37.06 / EED1100 • Developed the first domestic Embedded VCB • Passed KERI, KEMA, CESI development test • Standard Specification: IEC 62271-100 [M2, E2, C2 Class]

Vacuum Contact Switches

• Rated breaking time 6.3kA(16.4kA peak) • Minimize switch surge through optimal VI design • Standard Specification: IEC 60470, IEC 60282-1 • Realization of mechanical interlock between VCSs or with other devices

Load Break Switch/Auto Section Switch

• Maximum fuse combined capacity in the country-Max. 100A • LA & PF external combination structure • Easy to design single-body panel through optimal form design • Standard Specification: IEC 62271-105, IEC 60265-1, KEMC1126 • Compatible structure for LBS and ASS

Vacuum Transfer Switch

• Medium Voltage load transfer with Vacuum Interrupter • Easy maintenance with drawable structure • Small and light weight for 2 stage installation • Rating: 7.2kV 400/600A 12.5kA/sec Transfer Sequence: A ↔ off ↔ B

Current Limit Power Fuse

• Standardized external size with IEC & DIN Std • Excellent current limiting & cut off characteristics. • Optimal strikers (ensure tripping performance with LBSI • Rating: 7.2kV 50kA 24/25.8kV 40kA

• Minimized installation space (63% compared with MCSGI) • SF₆ gas free, environment friendly