ROSEMOUNT TANK GAUGING SYSTEM · Radar level gauge and radar level transmitter—independent level...

5
Always ready for your next challenge ROSEMOUNT TANK GAUGING SYSTEM ACCURACY EFFICIENCY SAFETY

Transcript of ROSEMOUNT TANK GAUGING SYSTEM · Radar level gauge and radar level transmitter—independent level...

Always ready for your next challenge

ROSEMOUNT TANK GAUGING SYSTEM

AC

CU

RA

CYEFFICIENCY

SAFE

TY

Future-proof design

New level of safety

Renowned accuracy

5900S Radar Level Gauge

Non-contact radar gauge for applications with high requirements on level measurement and overfill prevention.

Big words, we know. But Rosemount Tank Gauging System really takes tank gauging to another level. You will be better equipped to handle the ever-increasing demands on efficiency, safety and accuracy. You get a complete and flexible tank gauging system, giving you total freedom.

Ready to improve efficiencyThe Rosemount Tank Gauging System is based on the open industry standard Foundation™ fieldbus. This makes it easy to install exactly the devices you need today as well as adding or replacing units tomorrow. Having access to reliable and accurate tank content information in real time is key to high plant efficiency, as your operators can handle even more tanks, fill the tanks higher and better utilize the storage capacity. Rosemount Tank Gauging System takes you to top efficiency and lets you stay there.

Ready to improve safetyWith no moving parts, radar technology is fundamentally reliable. But Rosemount Tank Gauging System takes safety further than ever before. The 5900S gauge with a 2-in-1 feature can, for example, be delivered to meet SIL 3 requirements for overfill prevention.

Ready to improve accuracyFor decades, Rosemount radar tank gauges have been the obvious choice when precision is critical. The 5900S gauge builds upon this legacy by offering level measurement accuracy of ±0.5 mm (0.02 in.). But even if accuracy is important, the need can vary. That is why we include gauging solutions all the way from operational control only, to custody transfer performance with full inventory management functionality.

Welcome to a new era in tank gauging

TankMaster

Tank gauging software for inventory and custody transfer functions. Calculations can be based on API, ISO and other major industry standards. Smart Wireless

Gateway

Connects wireless devices on the tanks with the host system.

Whatever your next step,

you will be ready

The precision instruments of tank gauging

There are always new challenges to face in a tank storage facility. Expansion or refurbishing projects mean you have to connect new equipment to your in stallation. This is also the case when you replace damaged or outdated technology. Rosemount Tank Gauging System lets you meet your challenges so you can maintain high plant efficiency and protect the value of your tank gauging investment.

Practically unlimitedThanks to the use of an open commun-ications standard (Foundation™ fieldbus), Rosemount Tank Gauging System lets you combine gauging devices freely within your system. The bus-powered, two-wired Tankbus is self-configured and intrinsically safe allowing cabling without conduits which means lower installation cost. Long-

distance communication to the control room can be made via our TRL2 fieldbus or other major fieldbus standards. Wireless data transmission is also an option. This is especially valuable when it is necessary to cross roads or when distance or ground conditions make cabling expensive.

Upgrade graduallyThere are numerous tank farms with gauging based on older technology, even in fairly recent installations. But don’t worry. Rosemount Tank Gauging System can emulate gauges from other manufacturers. This means you can add Rosemount radar level gauges to your existing system.

Open and scalable

Two-wire bus or wireless

Emulation capabilities

www

5900S RadarLevel Gauges

644 with SpotTemperature

SmartWirelessTHUM

2230 GraphicalField Display

2410 Tank HubFn1 2 34 5 67 8 9. 0 -

FieldCommunicator

5300 GuidedWave Radar

565 Multiple Spot TemperatureSensor

2240S Multi- Input TemperatureTransmitter

765 Multiple Spot Temperature with Water Level Sensor

2240S

565

5900S

2410 THUM

5900S

3051S

2120 Liquid Level Switch 3051S Pressure

Transmitter

765

2160/65/75 FieldCommunication Unit

2180 FieldBus Modem

TankMasterPC Workstationin Network TankMaster.net

for web access

AlternativeConnectionto DCS

To DCS

AlternativeConnectionto DCS

Smart Wireless Gateway

5300

5400/5300

2410

644

2410

2410

2230

5900S2240S5400

3051S

5400 RadarLevel Transmitter

2410

644

5900S

5900S with LPG/LNG antenna

Pressurized or cryogenic liquefied gas

Strong echo even under surface boiling conditions

5900S with horn antenna

Fixed roof tanks without still-pipe

200–400 mm (8-16 in.) nozzles

Oil products and chemicals except for sticky liquids

5900S with parabolic antenna

Best choice in tanks without still-pipe

Demanding environ-ments with sticky or condensing liquids such as asphalt

5900S with still-pipe array antenna

New or existing still-pipes

Crude oil tanks with floating roofs

Gasoline tanks with/without inner floating roofs

5900S

2410

2410

2230

THUM

5900S

3051S

5900S RadarLevel Gauges

5400T RadarLevel Gauge

3051S PressureTransmitter

644 with SpotTemperature

SmartWirelessTHUM

2230 GraphicalField Display

2410 Tank Hub

5300T RadarLevel Gauges

AverageTemperatureSensor

2240S Multi Input TemperatureTransmitter

WLS WaterLevel Sensor

5900S RadarLevel Gauges

5400T RadarLevel Gauge

3051S PressureTransmitter

644 with SpotTemperature

SmartWirelessTHUM

2230 GraphicalField Display

2410 Tank Hub

5300T RadarLevel Gauges

AverageTemperatureSensor

2240S Multi Input TemperatureTransmitter

WLS WaterLevel Sensor

2240S

644

Rosemount Tank Gauging System gives you precise data for certified custody transfer, inventory management, and loss control. The level measurement accuracy of ±0.5 mm (0.02 in.), together with the highest precision average tem perature measurement, ensures exact net volume calculations. In cases where medium accuracy is sufficient, we offer a number of cost-effective gauging instruments.

Works everywhereRosemount Tank Gauging System suits all kinds of applications and tanks: pressurized and non-pressurized, with fixed or floating roofs, with or without still-pipes. This makes it the perfect choice for refineries, tank terminals, fuel depots, LNG plants and more.

The best there isWith Rosemount Tank Gauging System you enjoy precise tank gauging. More accurate

billing, better tank utilization and higher safety are some of the benefits. No moving parts also make the gauges reliable, virtually maintenance-free and long lasting. Simply put, the money you invest is soon paid back and turned into years of profits.

We invented radar tank gauging, delivered our first radar level gauge in 1975 and have since then delivered over 100 000 units all over the world—more than anyone else. Emerson´s tank gauging representatives are located worldwide, providing you with service and support from highly trained service engineers in more than 80 countries.

Taking safety to a higher level

When every drop counts, you can

count on radar technology

Wide range of overfill prevention options The pioneer in radar-based tank gauging

Unique 2-in-1 feature

SIL 2 and SIL 3 safety

Continuous surveillance

Accuracy of ±0.5 mm (0.02 in.)

Precise net volume calculations

All tank storage applications

World market leader

Proven performance

Always close at hand

... fo

r marin

e tankers

(1975)

… fo

r on-sh

ore ta

nks with

custody

transfe

r accura

cy (1984)

… w

ith 2-in

-1 and 3-in

-1

(2002)

… w

ith w

ireless

comm

unications

(2009)

… w

ith 2-in

-1 and SIL 3 sa

fety

(2010)

… w

ith SIL 2 certi

fication

(2007)

We introduced the world’s first radar level gauge …

Lawmakers, corporate management, members of the community—demands for increased safety come from just about everywhere. Rosemount Tank Gauging System allows you to meet existing and future requirements and protect plant assets, the environment and human lives.

World’s first high precision SIL 3 radarIn addition to measuring level, a 5900S radar level gauge can be used for overfill and dry-run prevention. Together with other radar devices and switches (see examples below)

and tank hubs you can achieve SIL 2/SIL 3 certified level alarm functionality. The 5900S is also available with two independent radar gauges in one housing (2-in-1) enabling SIL 3.

Radar never sleepsRosemount radar level gauges are always in operation. This is not the case with passive devices like traditional switches, where you can only be sure they are working at the very instant you run a test. With two separate gauges, you can compare the results and immediately spot if one gauge is not working.

5900S + 5900S

Dual radar gauges for level and overfill measurements. SIL 2 certified with the possibility to achieve SIL 3 safety level.

5900S + 5300/5400

Radar level gauge and radar level transmitter—independent level and continuous high-level alarm. Suitable for SIL 2 safety.

5900S + 2120

Radar level gauge and point level switch. Suitable for SIL 2 safety.

5900S (2-in-1)

Two radar gauges in one housing—independent level and overfill measurements. SIL 2 and SIL 3 safety.

The contents of this publication are presented for information purposes only, and while efforts have been made to ensure their accuracy, they are not to be construed as warranties or guarantees, expressed or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available on request. We reserve the right to modify or improve the designs or specifications of our products at any time without notice. Rosemount Tank Radar AB accepts no responsibility for any errors that may appear in this publication.

© R

osem

ount

Tan

k Ra

dar A

B. R

ef.N

o. 0

0803

-010

0-51

00, R

ev A

A, S

epte

mbe

r 201

4

Emerson Process ManagementRosemount Tank Gauging

Box 130 45SE-402 51 GöteborgSWEDENTel: +46 31 337 00 00Fax: +46 31 25 30 22E-mail: [email protected]

Emerson Process ManagementRosemount Tank Gauging North America Inc.

6005 Rogerdale RoadMail Stop NC 13677072 TX HoustonUnited StatesPrimary Phone: +1 281 988 4000Secondary Phone: +1 800 722 2865E-mail: [email protected]

Emerson Process ManagementRosemount Tank Gauging Middle East & Africa.

P. O Box 20048ManamaBahrainTel: +973 1722 6610Fax: +973 1722 7771E-mail: [email protected]

The Emerson logo is a trademark and service mark of Emerson Electric Co. Rosemount and the Rosemount logotype are registered trademarks of Rosemount Inc. PlantWeb is a registered trademark of one of the Emerson Process Management group of companies.HART and WirelessHART are registered trademarks of the HART Communication Foundation.All other marks are property of their respective owners. © 2014 Rosemount Tank Radar AB. All rights reserved.

Emerson Process ManagementAsia Pacific Pte Ltd

1 Pandan CrescentSINGAPORE 128461Tel: +65 6777 8211Fax: +65 6777 0947Email: [email protected]

Emerson Process ManagementLatin America

1300 Concord Terrace, Suite 400Sunrise Florida 33323United StatesTel: +1 954 846 5030