2
Area density 150 g/m² Fire resistance, EN 13501-1, EN 11925-2 E Resistance to water penetration, EN 13111 W1 Resistance to air penetration 0,05 m³/m² h 50 Pa Transmission of water vapour Sd, EN 12572 0,02 m Tensile strength, longitudinal direction, EN 12311-1 350 N/50 mm Tensile strength, transverse direction, EN 12311-1 210 N/50 mm Nail tear resistance, longitudinal direction, EN 12310-1 190N 190 N/50 mm Nail tear resistance, transverse direction, EN 12310-1 225N 225 N/50 mm Elongation, longitudinal direction 100 % Elongation, transverse direction 125 % Temperature range -40°C / +80°C UV stability, EN 13859-1 3 months Numéro de certificat / certificate number 17-001 http://evaluation.cstb.fr FLEXIBLE ROOFING MEMBRANES E S T 1 D1 R2 BENEFITS OF THE PRODUCT FIELDS OF APPLICATION AEROMAX R2, the universal roofing membrane, offers good permeability to water vapour and is particularly suitable for ventilated sloping roofs. The actual functional membrane, a high-permeance polyethylene film, is protected by a non-woven sheet that is tear-proof and UV-resistant. It is waterproof and protects the roofing underlay from harm in the event of any accidental infiltrations by water or snow. It is also airtight and contributes effectively to optimising the performance of the heat insulation for the roof. The membrane can be fitted in direct contact with the insulation. This allows you to save 20mm space compared with a non-breathable membrane, which needs a gap of 20mm underneath for ventilation purposes. The lower side, lined with a protective non-woven fabric layer, is also guaranteed to be easy and safe to fit to a timber shell. Please follow the fitting instructions. In terms of fire safety, the AEROMAX R2 membrane is not intended to constitute the ceilings of buildings occupied for residential purposes or establishments open to the public. ROOFING UNDERLAY MEMBRANE FOR CENTRE DISTANCE OF 60cm 3 MONTH UV EXPOSURE UP TO ALTITUDES OF 900m DENSITY 150g / m² W1 WATER RESISTANCE 3 LAYER COMPOSITE ROLL 1,5mx50m 3mx50m AEROMAX R2 60cm HIGH PERMEABILITY TO WATER VAPOUR FITTED IN DIRECT CONTACT WITH THE INSULATION TR2 FOR CENTRE DISTANCE OF 60cm BETWEEN RAFTERS ITTED ON CONTINOUS OR DISCONTINOUS SUBSTRATE ON THE UNDERLAY OR FACADE (AS HOUSE WRAP) COMPOSITION : 3 layers PP-PP-PP ENVIRONNEMENT ROOFING UNDERLAY To see compatible accessories for perfect airproofing or waterproofing, please refer to the table of features and compatible products STANDARDS/CERTIFICATES CE marking in accordance with EN 13859-1 Conforms to CPT 3560 version 2-07/2009 13

Transcript of ROOFING UNDERLAY MEMBRANE FOR CENTRE DISTANCE OF … · 2021. 3. 16. · Nail tear resistance,...

Page 1: ROOFING UNDERLAY MEMBRANE FOR CENTRE DISTANCE OF … · 2021. 3. 16. · Nail tear resistance, longitudinal direction, EN 12310-1 190N 190 N/50 mm Nail tear resistance, transverse

Area density 150 g/m²Fire resistance, EN 13501-1, EN 11925-2 EResistance to water penetration, EN 13111 W1Resistance to air penetration 0,05 m³/m² h 50 PaTransmission of water vapour Sd, EN 12572 0,02 m Tensile strength, longitudinal direction, EN 12311-1 350 N/50 mmTensile strength, transverse direction, EN 12311-1 210 N/50 mmNail tear resistance, longitudinal direction, EN 12310-1 190N 190 N/50 mmNail tear resistance, transverse direction, EN 12310-1 225N 225 N/50 mmElongation, longitudinal direction 100 %Elongation, transverse direction 125 %Temperature range -40°C / +80°CUV stability, EN 13859-1 3 months

Numéro de certificat / certificate number17-001

http://evaluation.cstb.fr

FLEXIBLE ROOFING MEMBRANES

EST

1D1R2

BENEFITS OFTHE PRODUCT

FIELDS OFAPPLICATION

AEROMAX R2, the universal roofing membrane, offers good permeability to water vapour and is particularly suitable for ventilated sloping roofs. The actual functional membrane, a high-permeance polyethylene film, is protected by a non-woven sheet that is tear-proof and UV-resistant. It is waterproof and protectsthe roofing underlay from harm in the event of any accidental infiltrations by water or snow. It is also airtight and contributes effectively to optimising the performance of the heat insulation for the roof.The membrane can be fitted in direct contact with the insulation. This allows you to save 20mm space compared with a non-breathable membrane, which needs a gap of 20mm underneath for ventilation purposes. The lower side, lined with a protective non-woven fabric layer, is also guaranteed to be easy and safe to fit to a timber shell. Please follow the fitting instructions. In terms of fire safety, the AEROMAX R2 membrane is not intended to constitute the ceilings of buildings occupied for residential purposes or establishments open to the public.

ROOFING UNDERLAYMEMBRANE FOR CENTREDISTANCE OF 60cm

3 MONTHUV

EXPOSURE

UP TOALTITUDESOF 900m

DENSITY150g / m²

W1 WATERRESISTANCE

3 LAYERCOMPOSITE

ROLL1,5mx50m3mx50m

AEROMAX R2

60cm

HIGH PERMEABILITY TO WATER VAPOUR

FITTED IN DIRECT CONTACT WITH THE INSULATION

TR2 FOR CENTRE DISTANCE OF 60cm BETWEEN RAFTERS

ITTED ON CONTINOUS OR DISCONTINOUS SUBSTRATE ON THE UNDERLAY OR FACADE(AS HOUSE WRAP)

COMPOSITION :3 layers PP-PP-PP

E N V I R O N N E M E N T

ROOFINGUNDERLAY

To see compatible accessories forperfect airproofing or waterproofing, please referto the table of features and compatible products

STANDARDS/CERTIFICATESCE marking in accordancewith EN 13859-1Conforms to CPT 3560 version 2-07/2009

13

Page 2: ROOFING UNDERLAY MEMBRANE FOR CENTRE DISTANCE OF … · 2021. 3. 16. · Nail tear resistance, longitudinal direction, EN 12310-1 190N 190 N/50 mm Nail tear resistance, transverse

Area density, EN1849-2 225 g/m²Fire resistance, EN 13501-1 FResistance to water penetration, EN 13111 W1Transmission of water vapour Sd, EN 1931 0,02 m (+0,02/-0,005)Tensile strength, longitudinal direction, EN 12311-1 400 N/50 mm (+100/-100)Tensile strength, transverse direction, EN 12311-1 330 N/50 mm (+100/-30°)Elongation, longitudinal direction, EN 12311-1 100 % (+100/-50)Elongation, transverse direction, EN 12311-1 150 % (+100/-100)Nail tear resistance, longitudinal direction, EN 12310-1 250 N (+100/-25)Nail tear resistance, transverse direction, EN 12311-1 310 N (+100/-85)Temperature range -40°C à +80°C UV stability 3 mois

STANDARDS/CERTIFICATESCE marking in accordancewith EN 13859-1Complies with UTD 40.29Numéro de certificat / certificate number

19-003http://evaluation.cstb.fr

FLEXIBLE ROOFING MEMBRANES

EST

1D1R3

FIELDS OFAPPLICATION

AEROMAX R3 PREMIUM, which offers exceptional permeability to water vapour, is particularly suitable for use as a roofing underlay membrane flush with the insulation and fitted to the battens. AEROMAX R3 PREMIUM is composed of 3 layers of 100% polyolefin.The actual functional membrane, a high-permeance polyethylene film, is protected by a non-woven sheet that is tear-proof and UV-resistant. It is waterproof and protects the roofing underlay from harm in the event of any accidental infiltrations by water or snow. It is also airtight and contributes effectively to optimising the performance of the heat insulation for the roof, whilst simultaneously being easy and perfectly safe to fit, even on battens. In terms of fire safety, the AEROMAX R3 PREMIUM membrane is not intended to constitute the ceilings of buildings occupied for residential purposes or establishments open to the public.

ROOFING UNDERLAYMEMBRANE FOR CENTREDISTANCE OF 90cm

AEROMAX R3 PREMIUM

90cm

HIGH PERMEABILITY TO WATER VAPOUR

FITTED IN DIRECT CONTACT WITH THE INSULATION

TR3 FOR CENTRE DISTANCE OF 90cm BETWEENRAFTERS

PERFECTLY WINDPROOF

FITTED ON CONTINOUS OR DISCONTINOUSSUBSTRATE ON THE UNDERLAYOR FACADE (AS HOUSE WRAP)

COMPOSITION :Composite of 3 PP-PP-PP layers

E N V I R O N N E M E N T

ROOFINGUNDERLAY

BENEFITS OFTHE PRODUCT

To see compatible accessories forperfect airproofing or waterproofing, please referto the table of features and compatible products

3 MONTHUV

EXPOSURE

UP TOALTITUDESOF 900m

DENSITY225g / m²

W1 WATERRESISTANCE

3 LAYERCOMPOSITE

ROLL1,5mx50m

16