ROOF REPLACEMENT HASTINGS PARK GARDEN AUDITORIUM

12
HASTINGS PARK GARDEN AUDITORIUM ROOF REPLACEMENT 2901 EAST HASTINGS STREET, VANCOUVER, B.C. COVER PAGE R-0.0 0 DMN AMa N.T.S. HASTINGS PARK GARDEN AUDITORIUM ROOF REPLACEMENT Sheet Title Project Name Drawn By Designed By RJC Project Number Sheet Number Revision MARCH 14, 2018 Date Scale VAN.100502.0005 2901 EAST HASTINGS, VANCOUVER, B.C. No. Revision Date By amachula P:\VAN\100500\VAN.100502.0005 - Hastings Park Garden Auditorium Roof Replacement\Drafting\VAN.100502.0005 (I) R-0.0 CP.dwg 18-03-14 13:47:40 Seal All drawings, plans, models, designs, specifications and other documents prepared by Read Jones Christoffersen Ltd. ("RJC") and used in connection with this project are instruments of service for the work shown in them (the "Work") and as such are and remain the property of RJC whether the Work is executed or not, and RJC reserves the copyright in them and in the Work executed from them, and they shall not be used for any other work or project. These drawings are "design drawings" only. They may not be suitable for use as shop drawings. Use of these drawings as base drawings for "shop drawings" is not permitted unless written permission containing certain conditions and limitations is obtained from RJC. The work "as constructed" may vary from what is shown on these drawings. Use of these drawings is limited to that identified in the Revision column. Do not construct from these drawings unless marked "Issued for Construction" by RJC in the Revision column, and then only for the parts noted. The drawings shall not be used for "pricing", "costing", or "tender" unless so indicated in the Revision column. "Pricing" or "Costing" drawings are not complete and any prices based on such drawings must allow for this. 3. 2. 1. Drawing Notes Read Jones Christoffersen Ltd. 1285 West Broadway, Suite 300 Vancouver, BC V6H 3X8 Canada 604-738-0048 604-738-1107 Engineers rjc.ca tel fax ISSUED FOR CLIENT REVIEW DEC 08/17 DMN ISSUED FOR 100% CLIENT REVIEW FEB 01/18 DMN ISSUED FOR BUILDING PERMIT FEB 07/18 DMN ISSUED FOR BID MAR 14/18 DMN

Transcript of ROOF REPLACEMENT HASTINGS PARK GARDEN AUDITORIUM

Page 1: ROOF REPLACEMENT HASTINGS PARK GARDEN AUDITORIUM

HASTINGS PARK GARDEN AUDITORIUMROOF REPLACEMENT

2901 EAST HASTINGS STREET,VANCOUVER, B.C.

COVER PAGE

R-0.0 0

DMN

AMa N.T.S.

HASTINGS PARK GARDENAUDITORIUM ROOFREPLACEMENT

Sheet Title

Project Name

Drawn By

Designed By

RJC Project Number

Sheet Number Revision

MARCH 14, 2018Date

Scale

VAN.100502.0005

2901 EAST HASTINGS,VANCOUVER, B.C.

No. Revision Date By

amachula P:\VAN\100500\VAN.100502.0005 - Hastings Park Garden Auditorium Roof Replacement\Drafting\VAN.100502.0005 (I) R-0.0 CP.dwg 18-03-14 13:47:40

Seal

All drawings, plans, models, designs, specifications and other documentsprepared by Read Jones Christoffersen Ltd. ("RJC") and used in connectionwith this project are instruments of service for the work shown in them (the"Work") and as such are and remain the property of RJC whether the Workis executed or not, and RJC reserves the copyright in them and in the Workexecuted from them, and they shall not be used for any other work or project.

These drawings are "design drawings" only. They may not be suitable foruse as shop drawings. Use of these drawings as base drawings for "shopdrawings" is not permitted unless written permission containing certainconditions and limitations is obtained from RJC. The work "as constructed"may vary from what is shown on these drawings.

Use of these drawings is limited to that identified in the Revision column.Do not construct from these drawings unless marked "Issued forConstruction" by RJC in the Revision column, and then only for the partsnoted. The drawings shall not be used for "pricing", "costing", or "tender"unless so indicated in the Revision column. "Pricing" or "Costing" drawingsare not complete and any prices based on such drawings must allow for this.

3.

2.

1.

Drawing Notes

Read Jones Christoffersen Ltd.

1285 West Broadway, Suite 300Vancouver, BC V6H 3X8 Canada

604-738-0048604-738-1107

Engineersrjc.ca

telfax

ISSUED FOR CLIENT REVIEW DEC 08/17 DMN

ISSUED FOR 100% CLIENTREVIEW FEB 01/18 DMN

ISSUED FOR BUILDING PERMIT FEB 07/18 DMN

ISSUED FOR BID MAR 14/18 DMN

Page 2: ROOF REPLACEMENT HASTINGS PARK GARDEN AUDITORIUM

WOOD FRAMING

GENERAL NOTES

DESIGN PARAMETERS

NON-BUILDING ENVELOPE ELEMENTS

FIELD REVIEW BY RJC

GENERAL SCOPE OF WORK

ABBREVIATIONS

STAGING

HASTINGS PARK GARDENAUDITORIUM ROOFREPLACEMENT

Sheet Title

Project Name

Drawn By

Designed By

RJC Project Number

Sheet Number Revision

MARCH 14, 2018Date

Scale

VAN.100502.0005

2901 EAST HASTINGS,VANCOUVER, B.C.

No. Revision Date By

amachula P:\VAN\100500\VAN.100502.0005 - Hastings Park Garden Auditorium Roof Replacement\Drafting\VAN.100502.0005 (I) R-1.1 SPAGN.dwg 18-03-14 13:47:58

Seal

All drawings, plans, models, designs, specifications and other documentsprepared by Read Jones Christoffersen Ltd. ("RJC") and used in connectionwith this project are instruments of service for the work shown in them (the"Work") and as such are and remain the property of RJC whether the Workis executed or not, and RJC reserves the copyright in them and in the Workexecuted from them, and they shall not be used for any other work or project.

These drawings are "design drawings" only. They may not be suitable foruse as shop drawings. Use of these drawings as base drawings for "shopdrawings" is not permitted unless written permission containing certainconditions and limitations is obtained from RJC. The work "as constructed"may vary from what is shown on these drawings.

Use of these drawings is limited to that identified in the Revision column.Do not construct from these drawings unless marked "Issued forConstruction" by RJC in the Revision column, and then only for the partsnoted. The drawings shall not be used for "pricing", "costing", or "tender"unless so indicated in the Revision column. "Pricing" or "Costing" drawingsare not complete and any prices based on such drawings must allow for this.

3.

2.

1.

Drawing Notes

Read Jones Christoffersen Ltd.

1285 West Broadway, Suite 300Vancouver, BC V6H 3X8 Canada

604-738-0048604-738-1107

Engineersrjc.ca

telfax

SITE PLAN AND GENERALNOTES

R-1.1 0

DMN

AMa N.T.S.

ISSUED FOR CLIENT REVIEW DEC 08/17 DMN

ISSUED FOR 100% CLIENTREVIEW FEB 01/18 DMN

ISSUED FOR BUILDING PERMIT FEB 07/18 DMN

ISSUED FOR BID MAR 14/18 DMN

Page 3: ROOF REPLACEMENT HASTINGS PARK GARDEN AUDITORIUM

HASTINGS PARK GARDENAUDITORIUM ROOFREPLACEMENT

Sheet Title

Project Name

Drawn By

Designed By

RJC Project Number

Sheet Number Revision

MARCH 14, 2018Date

Scale

VAN.100502.0005

2901 EAST HASTINGS,VANCOUVER, B.C.

No. Revision Date By

amachula P:\VAN\100500\VAN.100502.0005 - Hastings Park Garden Auditorium Roof Replacement\Drafting\VAN.100502.0005 (I) R-2.1 RP.dwg 18-03-14 13:24:49

Seal

All drawings, plans, models, designs, specifications and other documentsprepared by Read Jones Christoffersen Ltd. ("RJC") and used in connectionwith this project are instruments of service for the work shown in them (the"Work") and as such are and remain the property of RJC whether the Workis executed or not, and RJC reserves the copyright in them and in the Workexecuted from them, and they shall not be used for any other work or project.

These drawings are "design drawings" only. They may not be suitable foruse as shop drawings. Use of these drawings as base drawings for "shopdrawings" is not permitted unless written permission containing certainconditions and limitations is obtained from RJC. The work "as constructed"may vary from what is shown on these drawings.

Use of these drawings is limited to that identified in the Revision column.Do not construct from these drawings unless marked "Issued forConstruction" by RJC in the Revision column, and then only for the partsnoted. The drawings shall not be used for "pricing", "costing", or "tender"unless so indicated in the Revision column. "Pricing" or "Costing" drawingsare not complete and any prices based on such drawings must allow for this.

3.

2.

1.

Drawing Notes

Read Jones Christoffersen Ltd.

1285 West Broadway, Suite 300Vancouver, BC V6H 3X8 Canada

604-738-0048604-738-1107

Engineersrjc.ca

telfax

ROOF PLAN

R-2.1 0

DMN

AMa 1/8"=1'-0"

ISSUED FOR CLIENT REVIEW DEC 08/17 DMN

ISSUED FOR 100% CLIENTREVIEW FEB 01/18 DMN

ISSUED FOR BUILDING PERMIT FEB 07/18 DMN

ISSUED FOR BID MAR 14/18 DMN

Page 4: ROOF REPLACEMENT HASTINGS PARK GARDEN AUDITORIUM

SECTION

SECTION

HASTINGS PARK GARDENAUDITORIUM ROOFREPLACEMENT

Sheet Title

Project Name

Drawn By

Designed By

RJC Project Number

Sheet Number Revision

MARCH 14, 2018Date

Scale

VAN.100502.0005

2901 EAST HASTINGS,VANCOUVER, B.C.

No. Revision Date By

amachula P:\VAN\100500\VAN.100502.0005 - Hastings Park Garden Auditorium Roof Replacement\Drafting\VAN.100502.0005 (I) R-3.1 BS.dwg 18-03-14 13:25:05

Seal

All drawings, plans, models, designs, specifications and other documentsprepared by Read Jones Christoffersen Ltd. ("RJC") and used in connectionwith this project are instruments of service for the work shown in them (the"Work") and as such are and remain the property of RJC whether the Workis executed or not, and RJC reserves the copyright in them and in the Workexecuted from them, and they shall not be used for any other work or project.

These drawings are "design drawings" only. They may not be suitable foruse as shop drawings. Use of these drawings as base drawings for "shopdrawings" is not permitted unless written permission containing certainconditions and limitations is obtained from RJC. The work "as constructed"may vary from what is shown on these drawings.

Use of these drawings is limited to that identified in the Revision column.Do not construct from these drawings unless marked "Issued forConstruction" by RJC in the Revision column, and then only for the partsnoted. The drawings shall not be used for "pricing", "costing", or "tender"unless so indicated in the Revision column. "Pricing" or "Costing" drawingsare not complete and any prices based on such drawings must allow for this.

3.

2.

1.

Drawing Notes

Read Jones Christoffersen Ltd.

1285 West Broadway, Suite 300Vancouver, BC V6H 3X8 Canada

604-738-0048604-738-1107

Engineersrjc.ca

telfax

BUILDING SECTIONS

R-3.1 0

DMN

AMa 1/8"=1'-0"

ISSUED FOR CLIENT REVIEW DEC 08/17 DMN

ISSUED FOR 100% CLIENTREVIEW FEB 01/18 DMN

ISSUED FOR BUILDING PERMIT FEB 07/18 DMN

ISSUED FOR BID MAR 14/18 DMN

Page 5: ROOF REPLACEMENT HASTINGS PARK GARDEN AUDITORIUM

TYPICAL INTERNAL GUTTER

TYPICAL ROOF DRAIN

TYPICAL SCUPPER DETAIL AT GUTTER

TYPICAL LOW SLOPE ROOF MEMBRANEWATERPROOFING ASSEMBLY

TYPICAL ELECTRICAL CABLE PENETRATION

HASTINGS PARK GARDENAUDITORIUM ROOFREPLACEMENT

Sheet Title

Project Name

Drawn By

Designed By

RJC Project Number

Sheet Number Revision

MARCH 14, 2018Date

Scale

VAN.100502.0005

2901 EAST HASTINGS,VANCOUVER, B.C.

No. Revision Date By

amachula P:\VAN\100500\VAN.100502.0005 - Hastings Park Garden Auditorium Roof Replacement\Drafting\VAN.100502.0005 (I) R-4.1 D.dwg 18-03-14 13:54:08

Seal

All drawings, plans, models, designs, specifications and other documentsprepared by Read Jones Christoffersen Ltd. ("RJC") and used in connectionwith this project are instruments of service for the work shown in them (the"Work") and as such are and remain the property of RJC whether the Workis executed or not, and RJC reserves the copyright in them and in the Workexecuted from them, and they shall not be used for any other work or project.

These drawings are "design drawings" only. They may not be suitable foruse as shop drawings. Use of these drawings as base drawings for "shopdrawings" is not permitted unless written permission containing certainconditions and limitations is obtained from RJC. The work "as constructed"may vary from what is shown on these drawings.

Use of these drawings is limited to that identified in the Revision column.Do not construct from these drawings unless marked "Issued forConstruction" by RJC in the Revision column, and then only for the partsnoted. The drawings shall not be used for "pricing", "costing", or "tender"unless so indicated in the Revision column. "Pricing" or "Costing" drawingsare not complete and any prices based on such drawings must allow for this.

3.

2.

1.

Drawing Notes

Read Jones Christoffersen Ltd.

1285 West Broadway, Suite 300Vancouver, BC V6H 3X8 Canada

604-738-0048604-738-1107

Engineersrjc.ca

telfax

TYPICAL DETAILS

R-4.1 0

DMN

KJB/AMa AS SHOWN

ISSUED FOR CLIENT REVIEW DEC 08/17 DMN

ISSUED FOR 100% CLIENTREVIEW FEB 01/18 DMN

ISSUED FOR BUILDING PERMIT FEB 07/18 DMN

ISSUED FOR BID MAR 14/18 DMN

Page 6: ROOF REPLACEMENT HASTINGS PARK GARDEN AUDITORIUM

TYPICAL STEEP SLOPE ROOF ASSEMBLY

TYPICAL VENT STACK FLASHINGAT STEEP SLOPE ROOF

TYPICAL FLASHING DETAIL AT CURB JUNCTIONTYPICAL FLASHING DETAIL AT CORNERTYPICAL SADDLE FLASHING JOINTS

ROOF HATCH DETAIL

HASTINGS PARK GARDENAUDITORIUM ROOFREPLACEMENT

Sheet Title

Project Name

Drawn By

Designed By

RJC Project Number

Sheet Number Revision

MARCH 14, 2018Date

Scale

VAN.100502.0005

2901 EAST HASTINGS,VANCOUVER, B.C.

No. Revision Date By

amachula P:\VAN\100500\VAN.100502.0005 - Hastings Park Garden Auditorium Roof Replacement\Drafting\VAN.100502.0005 (I) R-4.2 TD.dwg 18-03-14 13:25:39

Seal

All drawings, plans, models, designs, specifications and other documentsprepared by Read Jones Christoffersen Ltd. ("RJC") and used in connectionwith this project are instruments of service for the work shown in them (the"Work") and as such are and remain the property of RJC whether the Workis executed or not, and RJC reserves the copyright in them and in the Workexecuted from them, and they shall not be used for any other work or project.

These drawings are "design drawings" only. They may not be suitable foruse as shop drawings. Use of these drawings as base drawings for "shopdrawings" is not permitted unless written permission containing certainconditions and limitations is obtained from RJC. The work "as constructed"may vary from what is shown on these drawings.

Use of these drawings is limited to that identified in the Revision column.Do not construct from these drawings unless marked "Issued forConstruction" by RJC in the Revision column, and then only for the partsnoted. The drawings shall not be used for "pricing", "costing", or "tender"unless so indicated in the Revision column. "Pricing" or "Costing" drawingsare not complete and any prices based on such drawings must allow for this.

3.

2.

1.

Drawing Notes

Read Jones Christoffersen Ltd.

1285 West Broadway, Suite 300Vancouver, BC V6H 3X8 Canada

604-738-0048604-738-1107

Engineersrjc.ca

telfax

TYPICAL DETAILS

R-4.2 0

DMN

AMa/KJB AS SHOWN

ISSUED FOR CLIENT REVIEW DEC 08/17 DMN

ISSUED FOR 100% CLIENTREVIEW FEB 01/18 DMN

ISSUED FOR BUILDING PERMIT FEB 07/18 DMN

ISSUED FOR BID MAR 14/18 DMN

Page 7: ROOF REPLACEMENT HASTINGS PARK GARDEN AUDITORIUM

LOW SLOPE TO STEEP SLOPE TRANSITION

GUTTER TRAY

LOWER CANOPY SECTION

CURVED CAP FLASHING AT LOWER CANOPY

BOX VENT AT SLOPED ROOF

HASTINGS PARK GARDENAUDITORIUM ROOFREPLACEMENT

Sheet Title

Project Name

Drawn By

Designed By

RJC Project Number

Sheet Number Revision

MARCH 14, 2018Date

Scale

VAN.100502.0005

2901 EAST HASTINGS,VANCOUVER, B.C.

No. Revision Date By

amachula P:\VAN\100500\VAN.100502.0005 - Hastings Park Garden Auditorium Roof Replacement\Drafting\VAN.100502.0005 (I) R-4.3 TD.dwg 18-03-14 13:25:59

Seal

All drawings, plans, models, designs, specifications and other documentsprepared by Read Jones Christoffersen Ltd. ("RJC") and used in connectionwith this project are instruments of service for the work shown in them (the"Work") and as such are and remain the property of RJC whether the Workis executed or not, and RJC reserves the copyright in them and in the Workexecuted from them, and they shall not be used for any other work or project.

These drawings are "design drawings" only. They may not be suitable foruse as shop drawings. Use of these drawings as base drawings for "shopdrawings" is not permitted unless written permission containing certainconditions and limitations is obtained from RJC. The work "as constructed"may vary from what is shown on these drawings.

Use of these drawings is limited to that identified in the Revision column.Do not construct from these drawings unless marked "Issued forConstruction" by RJC in the Revision column, and then only for the partsnoted. The drawings shall not be used for "pricing", "costing", or "tender"unless so indicated in the Revision column. "Pricing" or "Costing" drawingsare not complete and any prices based on such drawings must allow for this.

3.

2.

1.

Drawing Notes

Read Jones Christoffersen Ltd.

1285 West Broadway, Suite 300Vancouver, BC V6H 3X8 Canada

604-738-0048604-738-1107

Engineersrjc.ca

telfax

TYPICAL DETAILS

R-4.3 0

DMN

AMa AS SHOWN

ISSUED FOR CLIENT REVIEW DEC 08/17 DMN

ISSUED FOR 100% CLIENTREVIEW FEB 01/18 DMN

ISSUED FOR BUILDING PERMIT FEB 07/18 DMN

ISSUED FOR BID MAR 14/18 DMN

Page 8: ROOF REPLACEMENT HASTINGS PARK GARDEN AUDITORIUM

TYPICAL STACK VENT AT LOW SLOPE ROOFTYPICAL EXHAUST PENETRATION DETAIL

SECTION AT RIDGE

FLASHING DETAIL AT CHIMNEY

PARAPET AT CAST COPING - SOUTH ROOFCURB AT SOUTH ROOF

HASTINGS PARK GARDENAUDITORIUM ROOFREPLACEMENT

Sheet Title

Project Name

Drawn By

Designed By

RJC Project Number

Sheet Number Revision

MARCH 14, 2018Date

Scale

VAN.100502.0005

2901 EAST HASTINGS,VANCOUVER, B.C.

No. Revision Date By

amachula P:\VAN\100500\VAN.100502.0005 - Hastings Park Garden Auditorium Roof Replacement\Drafting\VAN.100502.0005 (I) R-4.4 TD.dwg 18-03-14 13:26:19

Seal

All drawings, plans, models, designs, specifications and other documentsprepared by Read Jones Christoffersen Ltd. ("RJC") and used in connectionwith this project are instruments of service for the work shown in them (the"Work") and as such are and remain the property of RJC whether the Workis executed or not, and RJC reserves the copyright in them and in the Workexecuted from them, and they shall not be used for any other work or project.

These drawings are "design drawings" only. They may not be suitable foruse as shop drawings. Use of these drawings as base drawings for "shopdrawings" is not permitted unless written permission containing certainconditions and limitations is obtained from RJC. The work "as constructed"may vary from what is shown on these drawings.

Use of these drawings is limited to that identified in the Revision column.Do not construct from these drawings unless marked "Issued forConstruction" by RJC in the Revision column, and then only for the partsnoted. The drawings shall not be used for "pricing", "costing", or "tender"unless so indicated in the Revision column. "Pricing" or "Costing" drawingsare not complete and any prices based on such drawings must allow for this.

3.

2.

1.

Drawing Notes

Read Jones Christoffersen Ltd.

1285 West Broadway, Suite 300Vancouver, BC V6H 3X8 Canada

604-738-0048604-738-1107

Engineersrjc.ca

telfax

TYPICAL DETAILS

R-4.4 0

DMN

AMa/KJB AS SHOWN

ISSUED FOR CLIENT REVIEW DEC 08/17 DMN

ISSUED FOR 100% CLIENTREVIEW FEB 01/18 DMN

ISSUED FOR BUILDING PERMIT FEB 07/18 DMN

ISSUED FOR BID MAR 14/18 DMN

Page 9: ROOF REPLACEMENT HASTINGS PARK GARDEN AUDITORIUM

SKYLIGHT AT SOUTH ROOF

CURVED PARAPET FLASHING AT SOUTH ROOFCURVED PARAPET FLASHING AT GUTTER

PARAPET ROOF ASSEMBLY AT ELECTRICAL ROOMBASE OF WALL AT ELECTRICAL ROOM ROOFDRAIN AT ELECTRICAL ROOM ROOF

TYPICAL DETAILS

R-4.5 0

DMN

AMa AS SHOWN

HASTINGS PARK GARDENAUDITORIUM ROOFREPLACEMENT

Sheet Title

Project Name

Drawn By

Designed By

RJC Project Number

Sheet Number Revision

MARCH 14, 2018Date

Scale

VAN.100502.0005

2901 EAST HASTINGS,VANCOUVER, B.C.

No. Revision Date By

amachula P:\VAN\100500\VAN.100502.0005 - Hastings Park Garden Auditorium Roof Replacement\Drafting\VAN.100502.0005 (I) R-4.5 TD.dwg 18-03-14 13:26:37

Seal

All drawings, plans, models, designs, specifications and other documentsprepared by Read Jones Christoffersen Ltd. ("RJC") and used in connectionwith this project are instruments of service for the work shown in them (the"Work") and as such are and remain the property of RJC whether the Workis executed or not, and RJC reserves the copyright in them and in the Workexecuted from them, and they shall not be used for any other work or project.

These drawings are "design drawings" only. They may not be suitable foruse as shop drawings. Use of these drawings as base drawings for "shopdrawings" is not permitted unless written permission containing certainconditions and limitations is obtained from RJC. The work "as constructed"may vary from what is shown on these drawings.

Use of these drawings is limited to that identified in the Revision column.Do not construct from these drawings unless marked "Issued forConstruction" by RJC in the Revision column, and then only for the partsnoted. The drawings shall not be used for "pricing", "costing", or "tender"unless so indicated in the Revision column. "Pricing" or "Costing" drawingsare not complete and any prices based on such drawings must allow for this.

3.

2.

1.

Drawing Notes

Read Jones Christoffersen Ltd.

1285 West Broadway, Suite 300Vancouver, BC V6H 3X8 Canada

604-738-0048604-738-1107

Engineersrjc.ca

telfax

ISSUED FOR CLIENT REVIEW DEC 08/17 DMN

ISSUED FOR 100% CLIENTREVIEW FEB 01/18 DMN

ISSUED FOR BUILDING PERMIT FEB 07/18 DMN

ISSUED FOR BID MAR 14/18 DMN

Page 10: ROOF REPLACEMENT HASTINGS PARK GARDEN AUDITORIUM

LIST OF STRUCTURAL DRAWINGS

DRAWINGS

GENERAL

ANALYSIS AND DESIGN CRITERIA

RENOVATIONSWOOD FRAMING

DESIGN LOADS

STRUCTURAL STEEL

STEEL DECK

PLYWOOD OVERLAY - LOWER LAYER

PLYWOOD OVERLAY - UPPER LAYER

TYPICAL PLYWOOD NAILING PATTERN

STRUCTURALGENERAL NOTES

Sheet Title

Project Name

Drawn By

Designed By

RJC Project Number

Sheet Number

S1.1 .Revision

JMH

HMB N/A

NOVEMBER, 2017Date

Scale

VAN.107371.0007

2901 EAST HASTINGS,VANCOUVER, B.C.

No. Revision Date By

KMills P:\VAN\107300\VAN.107371.0007 - City of Vancouver Roof Replacement Diaphragm Upgrades\Drafting\Hastings Park Garden\Hastings Park Garden - Sheets.dwg 18-03-14 10:44:19

Seal

All drawings, plans, models, designs, specifications and other documentsprepared by Read Jones Christoffersen Ltd. ("RJC") and used in connectionwith this project are instruments of service for the work shown in them (the"Work") and as such are and remain the property of RJC whether the Workis executed or not, and RJC reserves the copyright in them and in the Workexecuted from them, and they shall not be used for any other work or project.

These drawings are "design drawings" only. They may not be suitable foruse as shop drawings. Use of these drawings as base drawings for "shopdrawings" is not permitted unless written permission containing certainconditions and limitations is obtained from RJC. The work "as constructed"may vary from what is shown on these drawings.

Use of these drawings is limited to that identified in the Revision column.Do not construct from these drawings unless marked "Issued forConstruction" by RJC in the Revision column, and then only for the partsnoted. The drawings shall not be used for "pricing", "costing", or "tender"unless so indicated in the Revision column. "Pricing" or "Costing" drawingsare not complete and any prices based on such drawings must allow for this.

3.

2.

1.

Drawing Notes

Read Jones Christoffersen Ltd.

1285 West Broadway, Suite 300Vancouver, BC V6H 3X8 Canada

604-738-0048604-738-1107

Engineersrjc.ca

telfax

COORDINATION NOV 17/17 JMH

HASTINGS PARK GARDENAUDITORIUMROOF REPLACEMENT

ISSUED FOR REVIEW DEC 08/17 JMH

ISSUED FOR BUILDING PERMIT FEB 07/18 JMH

ISSUED FOR BID MAR 14/18 JMH

Page 11: ROOF REPLACEMENT HASTINGS PARK GARDEN AUDITORIUM

KEY NOTES

ROOF NOTES

DIMENSIONS

ROOF PLAN

ROOF PLANSSheet Title

Project Name

Drawn By

Designed By

RJC Project Number

Sheet Number

S2.1 .Revision

HMB 3/32"=1'-0"

Date

Scale

VAN.107371.0007

No. Revision Date By

KMills P:\VAN\107300\VAN.107371.0007 - City of Vancouver Roof Replacement Diaphragm Upgrades\Drafting\Hastings Park Garden\Hastings Park Garden - Sheets.dwg 18-03-14 10:44:19

Seal

All drawings, plans, models, designs, specifications and other documentsprepared by Read Jones Christoffersen Ltd. ("RJC") and used in connectionwith this project are instruments of service for the work shown in them (the"Work") and as such are and remain the property of RJC whether the Workis executed or not, and RJC reserves the copyright in them and in the Workexecuted from them, and they shall not be used for any other work or project.

These drawings are "design drawings" only. They may not be suitable foruse as shop drawings. Use of these drawings as base drawings for "shopdrawings" is not permitted unless written permission containing certainconditions and limitations is obtained from RJC. The work "as constructed"may vary from what is shown on these drawings.

Use of these drawings is limited to that identified in the Revision column.Do not construct from these drawings unless marked "Issued forConstruction" by RJC in the Revision column, and then only for the partsnoted. The drawings shall not be used for "pricing", "costing", or "tender"unless so indicated in the Revision column. "Pricing" or "Costing" drawingsare not complete and any prices based on such drawings must allow for this.

3.

2.

1.

Drawing Notes

Read Jones Christoffersen Ltd.

1285 West Broadway, Suite 300Vancouver, BC V6H 3X8 Canada

604-738-0048604-738-1107

Engineersrjc.ca

telfax

JMH NOVEMBER, 2017

2901 EAST HASTINGS,VANCOUVER, B.C.

COORDINATION NOV 17/17 JMH

ISSUED FOR REVIEW DEC 08/17 JMH

ISSUED FOR BUILDING PERMIT FEB 07/18 JMH

HASTINGS PARK GARDENAUDITORIUMROOF REPLACEMENT

ISSUED FOR BID MAR 14/18 JMH

Page 12: ROOF REPLACEMENT HASTINGS PARK GARDEN AUDITORIUM

SECTIONSECTION

TYPICAL INTERNAL GUTTERINTERNAL GUTTERISOMETRIC VIEW

BUILDING SECTIONSSheet Title

Project Name

Drawn By

Designed By

RJC Project Number

Sheet Number

S3.1 .Revision

HMB 1/8"=1'-0"

Date

Scale

VAN.107371.0007

No. Revision Date By

KMills P:\VAN\107300\VAN.107371.0007 - City of Vancouver Roof Replacement Diaphragm Upgrades\Drafting\Hastings Park Garden\Hastings Park Garden - Sheets.dwg 18-03-14 10:44:19

Seal

All drawings, plans, models, designs, specifications and other documentsprepared by Read Jones Christoffersen Ltd. ("RJC") and used in connectionwith this project are instruments of service for the work shown in them (the"Work") and as such are and remain the property of RJC whether the Workis executed or not, and RJC reserves the copyright in them and in the Workexecuted from them, and they shall not be used for any other work or project.

These drawings are "design drawings" only. They may not be suitable foruse as shop drawings. Use of these drawings as base drawings for "shopdrawings" is not permitted unless written permission containing certainconditions and limitations is obtained from RJC. The work "as constructed"may vary from what is shown on these drawings.

Use of these drawings is limited to that identified in the Revision column.Do not construct from these drawings unless marked "Issued forConstruction" by RJC in the Revision column, and then only for the partsnoted. The drawings shall not be used for "pricing", "costing", or "tender"unless so indicated in the Revision column. "Pricing" or "Costing" drawingsare not complete and any prices based on such drawings must allow for this.

3.

2.

1.

Drawing Notes

Read Jones Christoffersen Ltd.

1285 West Broadway, Suite 300Vancouver, BC V6H 3X8 Canada

604-738-0048604-738-1107

Engineersrjc.ca

telfax

JMH NOVEMBER, 2017

2901 EAST HASTINGS,VANCOUVER, B.C.

COORDINATION NOV 17/17 JMH

ISSUED FOR REVIEW DEC 08/17 JMH

ISSUED FOR BUILDING PERMIT FEB 07/18 JMH

HASTINGS PARK GARDENAUDITORIUMROOF REPLACEMENT

ISSUED FOR BID MAR 14/18 JMH