Roof Hatches Heat and Smoke Vents Sidewalk and Floor … · ¤ Roof Hatches ¤ Heat and Smoke Vents...

26
Roof Hatches Heat and Smoke Vents Sidewalk and Floor Doors Distributed by: BEST MATERIALS LLC Ph: 800-474-7570, 602-272-8128 Fax: 602-272-8014 Email: [email protected] www.bestmaterials.com

Transcript of Roof Hatches Heat and Smoke Vents Sidewalk and Floor … · ¤ Roof Hatches ¤ Heat and Smoke Vents...

♦♦♦♦♦ Roof Hatches♦♦♦♦♦ Heat and Smoke Vents♦♦♦♦♦ Sidewalk and Floor Doors

Distributed by: BEST MATERIALS LLCPh: 800-474-7570, 602-272-8128 Fax: 602-272-8014Email: [email protected] www.bestmaterials.com

SINCE 1902

All information is subject to change without notice. Dimensions and specifications shown are within manufacturing tolerances.© Copyright, January 2008, Commercial Products Group of Hart & Cooley, Inc. All Rights Reserved.

ExperienceMilcor brings over 105 years of experience in themanufacturing of a broad range of products.

EngineeringEvery Milcor vent, hatch or door product isengineered to meet the specific in-userequirements of the application for which itwas designed.

SelectionThe Milcor product line contains the items to meetyour construction needs.

On-Time DeliveryMilcor appreciates the need for on-time delivery ofour products to meet your schedules.

Product Index

QualityMilcor smoke vents, roof hatches and floor doorsprovide superior performance features unequaledelsewhere in the industry.

WarrantyMilcor warrants all goods sold to be free from defects inworkmanship, but limits liability to five years from dateof shipment and expressly to the replacement of goodsnot complying with this warranty; or, at our election, acredit to original purchaser for the original purchaseprice paid less 1/60th of the price for each month elapsedfrom the original invoice date to the date of claimagainst this warranty.

Electric motors, special finishes and any other optionalspecial components required shall be warrantedseparately by the manufacturers of those products.

Roof Access HatchesOverall Product Benefits and Options 3Single Leaf: Spring Mounted in Cover 4Single Leaf: Spring Mounted in Frame 5Double Leaf 6Roof Hatch Accessories: Upright Safety Bar 7Roof Hatch Accessories: Safety Railing 7Quick Reference Chart 8Technical Specifications 10

Heat and Smoke VentsOverall Product Benefits and Options 11Big Smoky® & Low Profile 12STC-40 and STC-45 Acoustical 14UL-SKY Translucent Panel 16UL-SEE Domed 17Technical Specifications 18

Sidewalk and Floor DoorsOverall Product Benefits and Options 20Floor Doors Non-Security: Aluminum 21Floor Doors Security: Aluminum 22Floor Doors Security: Steel or Steel Frame/ Aluminum Cover 23Sidewalk & Floor Doors: Steel and Aluminum 24Technical Specifications 25

Distributed by: BEST MATERIALS LLC, Phoenix AZ602-272-8128 800-474-7570 www.bestmaterials.com

Roof Access HatchesTechnical Product Information

SINCE 1902

All information is subject to change without notice. Dimensions and specifications shown are within manufacturing tolerances.© Copyright, January 2008, Commercial Products Group of Hart & Cooley, Inc. All Rights Reserved.

LADDER ACCESSMinimum 2’6”x3’0”

SHIP STAIRMinimum 2’6”x4’6”

SERVICE STAIRMinimum 2’6”x8’0”

Stainless Steel HardwareFor Installation in highly corrosive environment, roofhatches are available with stainless steel hardware.

MotorizedRoof hatches can be equipped with motor operatorsfor opening and closing the covers from a remote 3-position selector switch.

• EASY COMPLETE OPENINGMilcor hatch covers open easily to 90 degrees. Operation isassisted by enclosed torsion bar or torsion coil spring operators.Automatic hold-open arms keep doors securely open.

• UNOBSTRUCTED OPENINGThe clear hatch opening is virtually unobstructed, with only anarrow hold-open arm at one corner and the torsion bar or springmounted out of the way in the cover or frame.

• COMPLETE SEALHeavy, closed cell, rubber gaskets factory-applied tothe units provide a barrier to weather penetrationand drafts. Latching devices with inside and outsidehandles hold hatches tightly closed.

• CHOICE OF MATERIALSHatches are available in several materials, includinggalvanized steel, aluminum, aluminum cover/galvanized steel curb or stainless steel. Galvanizedsteel is prime painted with rust inhibiting primer.

• THERMAL EFFICIENCIESHatch covers are insulated to keep heat in duringwinter and to repel the sun’s heat in summer. M,RBS and RCS Models feature composite-designcover construction for insulating efficiency. The rigidpolystyrene foam insulation in the covers providesU-factors ranging from 0.093 to 0.173. Milcor roofhatches are also available in RB, RC and RDmodels with fiberglass-insulated covers providing aU-value of 0.26. Curbs are insulated with 1" thickrigid fiberboard insulation.

• HIGH LOAD CAPACITYM, RBS and RCS models composite cover design provides load-carrying strengths to 70 psf. RB, RD and RC models can carrylive loads up to 40 psf.

• COMPLETE SELECTIONMilcor roof hatches are available in single- and double-leafconfigurations, depending upon the size of the units. Single-leafM and RBS and RD-1 models are available in 3' x 2'-6" and 3’ x3’ with a torsion bar mounted in the cover. RB, RC and mostother RD models are available in all sizes with the springsmounted on the frame, offering added strength with larger sizes.Standard size double-leaf units range from 5' x 11' to 8' x 8'.

• SPECIAL UNITSHatches can be fabricated in special sizes, shapes, or othermodifications to meet special needs. Consult the Milcor factoryfor details.

Overall Product Benefits

Selecting the ProperSize Hatch

The angle at which a person ascends to the roofdetermines the size hatch required for convenientuse. If a ladder is used, the hatch may be rathersmall since the person comes straight up to theroof. As the angle of ascent decreases, the hatchmust be larger to prevent head-bumping accidents.Recommended minimum sizes for various types ofroof access are shown above. If movement ofbulky materials through the hatch is anticipated,double-leaf hatches with openings up to 66 sq. ft.or larger are available. Recent changes to theInternational Building Code require 16 sq. ft open-ings as the standard for various structures.

Note-the second dimension on hatch sizes denotes the length on thehinge side.

Roof Hatch Options

Roof Access HatchesTechnical Product Information

SINCE 1902

All information is subject to change without notice. Dimensions and specifications shown are within manufacturing tolerances.© Copyright, January 2008, Commercial Products Group of Hart & Cooley, Inc. All Rights Reserved.

Single Leaf: Spring Mounted in Cover• Access and Ventilation

Provides convenient access to the building’s roof. Maybe open for auxiliary ventilation.

• Unobstructed OpeningNarrow hold-open arm and torsion bar are mounted outof the way in the cover. Hasp is clear of opening.

• High Load CapacityThe composite cover design on M, RBS, RCS and RD-1Models provides load-carrying strengths to 70 psf.

• Easy, Complete OpeningCovers open easily to 90°. Torsion spring and automatichold-open arms assist operation and keep doorssecurely open.

• Complete SealHeavy, mechanically-applied weather seal provides abarrier to weather and drafts. Latches with inside andoutside handles hold hatches tightly closed, allowingeasy access from inside or outside the hatch.

• Choice of MaterialsHatches are available in galvanized steel, aluminum,aluminum cover with galvanized curb or stainless steel.

• High Thermal EfficiencyCovers are insulated with 1 inch of high efficiencystyrofoam insulation. Keeps heat in during winter andrepels heat in summer. Frames are insulated with 1 inchexterior fiberboard insulation.

• Custom UnitsHatches can be fabricated in special sizes, shapes orother modifications to meet special needs such as arerequired for:• Metal Roofs • Corrosive Environments• Domed units • Curb Mounted Units• High Security • Higher r-value insulation

MaterialsGalvanized Steel, Prime Painted

Galvanized Steel, Prime Painted

Aluminum Cover, Galvanized Curb

Aluminum Cover and Curb

Model No. Lbs.M-1 185

RBS-1 155

RCS-1 120

RD-1 125

Standard Sizes and Model Number*Single Leaf Units, Spring Mounted in Cover (Second dimension is for length on hinge side.)

3' 0" x 2' 6" 3' 0" x 3' 0"Model No. Lbs.M-3x3 254

-

RCS-3x3 190

-

*Special made-to-order sizes are available for each model

Concealedtorsion spring

Composite coverconstruction with

rigid styrofoaminsulation

Closed cell rubberweather seal

90° ClearOpening withautomatic holdopen arm

100% Clearopening

Lock-bolt latchesinto curb slot

Distributed by: BEST MATERIALS LLC, Phoenix AZ602-272-8128 800-474-7570 www.bestmaterials.com

Roof Access HatchesTechnical Product Information

SINCE 1902

All information is subject to change without notice. Dimensions and specifications shown are within manufacturing tolerances.© Copyright, January 2008, Commercial Products Group of Hart & Cooley, Inc. All Rights Reserved.

Weather Seal

Spring Latch with Inside & OutsideHandles & Inside Padlock Hasp

Automatic Hold Open Arm

Cover

1" Fiberglass Insulation orStyrofoam Insulation

Liner

CounterFlashing

31/2" Flange *Hatch SizeDimensions are to the Inside of Curb

12"Curb

1" FiberboardInsulation

Enclosed SpringOperator

Single Leaf: Spring Mounted in Frame• Access and Ventilation

Provides convenient access to the building’s roof. May be openedfor auxiliary ventilation.

• Multiple SizesUsing heavy-duty enclosed torsion spring design, which is mountedin the hatch frame, the opening assist is especially enhanced whenused on larger units.

• Powerful Load CapacityRB, RD and RC models handle live loads up to 40 psf, standardindustry strength. Milcor’s M, RBS RCS and RDS models, withcomposite cover design, provide load-carrying strengths to 70 psf.

• Complete SealHeavy, mechanically-applied weather seal provides a barrier toweather and drafts. Latches with inside and outside handles holdhatches tightly closed, allowing easy access from inside or outsidethe hatch.

• Choice of MaterialsHatches are available in galvanized steel, aluminum, aluminumcover with galvanized curb or stainless steel.

• High Thermal EfficiencyM, RBS, RBS-S, RDS-S and RCS covers are liner bonded to a 1 or2 inch core of rigid styrofoam-type insulation for high efficiencythermal protection. RB, RD and RC covers contain the industrystandard 1” of rigid fiberglass insulation. Both types keep the heat induring the winter and the heat out in the summer. Curbs have 1”exterior fiberboard as a standard feature.

• Custom UnitsHatches can be fabricated in special sizes, shapes or othermodifications to meet special needs, such as required with:• Smoke Hatches • Skylight Domes• High Security • Curb Mounted Units• Metal Roofs • Corrosive Environments

MaterialsGalvanized Steel

Galvanized Steel

Galvanized Steel

Alum Cover/ Galv Curb

Alum Cover/ Galv Curb

Alum Cover and Curb

Standard Sizes and Model Numbers*Single Leaf Units, Spring mounted in Frame (Second dimension is for length on hinge side.)

4' 0" x 4' 0"Model No. Lbs.RB-4x4 365

M-7 365

RBS-4X4 271

-

-

-

Model No. Lbs.RB-3 425

M-3 395

RBS-3 335

RCS-3 230

RC-3 307

RD-3 248

**2' 6" x 8' 0"2' 6" x 4' 6"Model No. Lbs.RB-2 255

M-2 265

RBS-2 225

RCS-2 140

RC-2 174

RD-2 136

Model No. Lbs.RB-1 205

- -

RBS-S (Smoke) 155

- -

RC-1 160

RDS-S (Smoke) 85

3' 0" x 2' 6"

*Special made-to-order sizes are available for each model.**Covers larger than 4’ 6” have a 2-point snap latch with inside and outside handles and inside padlock hasp.

3' 0" x 3' 0"Model No. Lbs. -

-

-

-

-

RD-3x3 155

SINCE 1902

All information is subject to change without notice. Dimensions and specifications shown are within manufacturing tolerances.© Copyright, January 2008, Commercial Products Group of Hart & Cooley, Inc. All Rights Reserved.

Hatch Size Dimensions are to inside the curb

Weather Seal

AutomaticHold-Open Arm

1" FiberboardInsulation

CounterFlashing

Curb

Weather Seal

2-Point Latch on EachLeaf. Inside Padlock Haspon Female Leaf

12”

1" Fiberglass Insulation

AutomaticHold-Open Arm

31/2" 31/2"Enclosed Torsion CoilSpring Operator

12” 1/2”

Double Leaf: Spring Mounted in Frame

• Automatic Hold-Open ArmsHold-open arms automatically lock the doors at 90o toprevent over-travel when doors are opened.

• Flawless Weather SealSloped covers are mounted to steel pintle hinges andare made weathertight with a closed-cell rubber seal.

• Choice of MaterialsHatches are available in galvanized steel, aluminum, oraluminum covers with a galvanized curb.

• Effective Insulations1 inch insulation in cover and on curb keeps heat induring winter months and repels heat throughout thesummer.

• Custom UnitsHatches can be fabricated in special sizes, shapes orother modifications to meet special needs, such asrequired with:• Skylight Domes • High Security• Curb Mounted • Metal Roofs

Standard Sizes and Model Number*Double Leaf Units (Second dimension is for length on hinge side.)

MaterialsGalvanized Steel, Prime PaintedAluminum Cover, Galvanized CurbAluminum Cover and Curb

Model No. Lbs.RB-4 1831RC-4 1220RD-4 1055

Model No. Lbs.RB-5 2060RC-5 1332RD-5 1166

Model No. Lbs. - -RC-6 1220RD-6 1055

5' 0" x 11' 0" 8' 0" x 8' 0"6' 0" x 11' 0"

*Special made to order sizes are available for each model.Units over 7’0” in either direction may require shipment in two sections. Units exceding sizes above may require removable center mullion.

Sloped Cover

• Provides Large Roof OpeningMilcor Double-Leaf Roof Hatches are designed for access whereadditional opening size is required.

• Easy, Complete OpeningHeavy-duty torsion coil spring operators, enclosed and located inframe, provide easy opening and closing of the hatch covers. Atwo-point latch assures tight, secure closure. Operating handles areprovided for access from inside or outside.

Roof Access HatchesTechnical Product Information

Distributed by: BEST MATERIALS LLC, Phoenix AZ602-272-8128 800-474-7570 www.bestmaterials.com

SINCE 1902

All information is subject to change without notice. Dimensions and specifications shown are within manufacturing tolerances.© Copyright, January 2008, Commercial Products Group of Hart & Cooley, Inc. All Rights Reserved.

Pipe: 1-1/4" ID A53Grade B seamed steel

Galvanizedbrackets

Pipe Plugs: Weatherand light resistant forpipe ends

Chain System: 3/16" proofcoil ASTM specification,zinc plated with quick linkand “S” hook

Bolts: Hex head bolts 3/8",grade Z, zinc plated withmanufacturer’s standardwashers inside and outside

Upright Safety Bar

Safety Railing

The Milcor Upright Safety Bar is designed to assist in the safepassage when exiting and entering the roof hatch. A heavy-duty, hinged steel mechanism allows the upward and downwardmovement of the bright yellow safety bar.

No need to attach bar to center of ladder rungs. Milcor’sUpright Safety Bar has been designed to provide the safest wayto exit and enter a roof hatch without restricting the opening orfooting on the top rungs of the ladder.

The Milcor safety rail is designed to aid in safe passagethrough the roof hatch and to protect the roof opening whilethe hatch is open. The railing system consists of a top rail,mid-rail and chain or optional swinging gate with the hatchcurb acting as the toe plate.

Rail, Upright Assembly

Pin, Pmot-Railtube

Pal-Nut, 3/8" Plated (2 req’d)

3 5 3/4" R e f .

3 5 1/2" R e f .

Quality Design andConstruction

• Simple and safe lift-and-lock into place movement.• Side location for safer and more convenient passage.

• Automatically locks when fully extended.• Shipped as a separate unit. Also available assembled to roof hatch.• Designed for hatches 4-foot and smaller on the ladder side.• Designed to provide approximately 42" height above ladder.

Curb mounted boltedbrackets

Roof Access Hatch AccessoriesTechnical Product Information

MEETS OSHA REQUIREMENTS

Strong Steel ConstructionMaintains Original Strength.

Does Not Become Brittle or Lose StrengthDue to Prolonged Exposure to UV Deterioration

SINCE 1902

All information is subject to change without notice. Dimensions and specifications shown are within manufacturing tolerances.© Copyright, January 2008, Commercial Products Group of Hart & Cooley, Inc. All Rights Reserved.

ModelNo.M-1RB-1RBS-1RC-1RCS-1RD-1M-3x3RCS-3x3RD-3x3M-7RB-4x4RBS-4x4M-2RB-2RBS-2RC-2RCS-2RD-2M-3RB-3RBS-3RC-3RCS-3RD-3

ModelNo.RB-4RC-4RD-4RB-5RC-5RD-5RC-6RD-6

ModelNo.RBS-SRDS-S

Item No.

3501-501-93501-112-93501-111-93501-122-93501-121-93501-132-93501-410-93501-610-93501-710-93501-515-93501-304-93501-302-93501-511-93501-115-93501-116-93501-125-93501-124-93501-135-93501-512-93501-118-93501-119-93501-128-93501-127-93501-138-9

Item No.

3501-212-93501-222-93501-232-93501-215-93501-225-93501-235-93501-228-93501-238-9

Item No.

3501-305-93501-310-9

Size

3'0"x2'6"3'0"x2'6"3'0"x2'6"3'0"x2'6"3'0"x2'6"3'0"x2'6"3'0"x3'0"3'0"x3'0"3'0"x3'0"4'0"x4'0"4'0"x4'0"4'0"x4'0"2'6"x4'6"2'6"x4'6"2'6"x4'6"2'6"x4'6"2'6"x4'6"2'6"x4'6"2'6"x8'0"2'6"x8'0"2'6"x8'0"2'6"x8'0"2'6"x8'0"2'6"x8'0"

Size

5'0"x11'0"5'0"x11'0"5'0"x11'0"6'0"x11'0"6'0"x11'0"6'0"x11'0"8'0"x8'0"8'0"x8'0"

Size

3’0”x2’6”3’0”x2’6”

TypicalAccessLadderLadderLadderLadderLadderLadderLadderLadderLadderLadderLadderLadderShip StairShip StairShip StairShip StairShip StairShip StairService StairService StairService StairService StairService StairService Stair

Access Style

Equipment AccessEquipment AccessEquipment AccessEquipment AccessEquipment AccessEquipment AccessEquipment AccessEquipment Access

Access Style

LadderLadder

ExternalCover14 Ga. Galv.14 Ga. Galv.18 Ga. Galv..090 Alum..063 Alum..090 Alum.14 Ga. Galv..063 Alum..090 Alum.14 Ga. Galv.14 Ga. Galv.18 Ga. Galv.14 Ga. Galv.14 Ga. Galv.18 Ga. Galv..090 Al.063 Alum..090 Alum.14 Ga. Galv.14 Ga. Galv.18 Ga. Galv.14 Ga. Galv..063 Alum..090 Alum.

ExternalCover14 Ga. Galv..090 Alum..090 Alum.14 Ga. Galv..090 Alum..090 Alum..090 Alum..090 Alum.

ExternalCover18 Ga. Galv..090 Alum.

InternalCover22 Ga. Galv.22 Ga. Galv.22 Ga. Galv..063 Alum..063 Alum..063 Alum.22 Ga. Galv..063 Alum..063 Alum.22 Ga. Galv.22 Ga. Galv.22 Ga. Galv.22 Ga. Galv.22 Ga. Galv.22 Ga. Galv..063 Alum..063 Alum..063 Alum.22 Ga. Galv.22 Ga. Galv.22 Ga. Galv.22 Ga. Galv..063 Alum..063 Alum.

InternalCover22 Ga. Galv..063 Alum..063 Alum.22 Ga. Galv..063 Alum..063 Alum..063 Alum..063 Alum.

InternalCover22 Ga. Galv..063 Alum.

CoverInsulation1” Rigid FoamFiberglass1” Rigid FoamFiberglass1" Rigid Foam1" Rigid Foam1" Rigid Foam1" Rigid FoamFiberglass1" Rigid FoamFiberglass1" Rigid Foam1" Rigid FoamFiberglass1" Rigid FoamFiberglass1" Rigid FoamFiberglass1" Rigid FoamFiberglass1" Rigid FoamFiberglass1" Rigid FoamFiberglass

CoverInsulationFiberglassFiberglassFiberglassFiberglassFiberglassFiberglassFiberglassFiberglass

CoverInsulation1” Rigid Foam1” Rigid Foam

OpeningOperatorTorsion BarTorsion SpringTorsion BarTorsion SpringTorsion BarTorsion SpringTorsion BarTorsion BarTorsion SpringTorsion SpringTorsion SpringTorsion SpringTorsion SpringTorsion SpringTorsion SpringTorsion SpringTorsion SpringTorsion SpringTorsion SpringTorsion SpringTorsion SpringTorsion SpringTorsion SpringTorsion Spring

OpeningOperatorTorsion SpringTorsion SpringTorsion SpringTorsion SpringTorsion SpringTorsion SpringTorsion SpringTorsion Spring

OpeningOperatorTorsion SpringTorsion Spring

Single Leaf Hatches

Double Leaf Hatches

Torsion Bar available only in Single Leaf Mounted in CoverTorsion Spring available only in Single Leaf Mounted in Frame

12” Curb

14 Ga. Galv.14 Ga. Galv.16 Ga. Galv.14 Ga. Galv.16 Ga. Galv..090 Alum.14 Ga. Galv.16 Ga. Galv..090 Alum.14 Ga. Galv.14 Ga. Galv.16 Ga. Galv.14 Ga. Galv.14 Ga. Galv.16 Ga. Galv.14 Ga. Galv.16 Ga. Galv..090 Alum.14 Ga. Galv.14 Ga. Galv.16 Ga. Galv.14 Ga. Galv.16 Ga. Galv..090 Alum.

12” Curb

14 Ga. Galv.14 Ga. Galv..090 Alum.14 Ga. Galv.14 Ga. Galv..090 Alum.14 Ga. Galv..090 Alum.

12” Curb

16 Ga. Galv..090 Alum.

Smoke Hatches (Operate as a roof hatch or heat and smoke hatch with 165 degree fusible link.

Quick Reference Roof HatchesTechnical Product Information

SINCE 1902

All information is subject to change without notice. Dimensions and specifications shown are within manufacturing tolerances.© Copyright, January 2008, Commercial Products Group of Hart & Cooley, Inc. All Rights Reserved.

Inside & OutsideHandles

YesYesYesYesYesYesYesYesYesYesYesYesYesYesYesYesYesYesYesYesYesYesYesYes

Inside &Outside Handles

YesYesYesYesYesYesYesYes

Inside &Outside Handles

YesYes

Inside PadlockHasp

YesYesYesYesYesYesYesYesYesYesYesYesYesYesYesYesYesYesYesYesYesYesYesYes

InsidePadlock Hasp

YesYesYesYesYesYesYesYes

InsidePadlock Hasp

YesYes

BottomMtg. Flg.3-1/2" wide3-1/2" wide3-1/2" wide3-1/2" wide3-1/2" wide3-1/2" wide3-1/2" wide3-1/2" wide3-1/2" wide3-1/2" wide3-1/2" wide3-1/2" wide3-1/2" wide3-1/2" wide3-1/2" wide3-1/2" wide3-1/2" wide3-1/2" wide3-1/2" wide3-1/2" wide3-1/2" wide3-1/2" wide3-1/2" wide3-1/2" wide

BottomFlange3-1/2" wide3-1/2" wide3-1/2" wide3-1/2" wide3-1/2" wide3-1/2" wide3-1/2" wide3-1/2" wide

BottomFlange3-1/2" wide3-1/2" wide

Finish

Primed GrayPrimed GrayPrimed GrayCurb Gray/ Cover MillCurb Gray/ Cover MillMill FinishPrimed GrayCurb Gray/ Cover MillMill FinishPrimed GrayPrimed GrayPrimed GrayPrimed GrayPrimed GrayPrimed GrayCurb Gray/ Cover MillCurb Gray/ Cover MillMill FinishPrimed GrayPrimed GrayPrimed GrayPrimed GrayCurb Gray/ Cover MillMill Finish

Finish

Prime PaintCurb Gray/ Cover MillMill FinishPrime PaintCurb Gray/ Cover MillMill FinishCurb Gray/ Cover MillMill Finish

Finish

Prime PaintMill Finish

PageNo.

454545445555555555555555

PageNo.

66666666

PageNo.

55

WeightEstimate

185205155160120125254190155365365271265255225174140136395425335307230248

WeightEstimate

18311220105520601332116612201055

WeightEstimate

155125

Exterior CurbInsulation1” Fiberboard1” Fiberboard1” Fiberboard1” Fiberboard1” Fiberboard1” Fiberboard1” Fiberboard1” Fiberboard1” Fiberboard1” Fiberboard1” Fiberboard1” Fiberboard1” Fiberboard1” Fiberboard1” Fiberboard1” Fiberboard1” Fiberboard1” Fiberboard1” Fiberboard1” Fiberboard1” Fiberboard1” Fiberboard1” Fiberboard

1” Fiberboard

Exterior CurbInsulation1” Fiberboard1” Fiberboard1” Fiberboard1” Fiberboard1” Fiberboard1” Fiberboard1” Fiberboard1” Fiberboard

Exterior CurbInsulation1” Fiberboard1” Fiberboard

Quick Reference Roof HatchesTechnical Product Information

Single Leaf Hatches

Double Leaf Hatches

Smoke Hatches (Operate as a roof hatch or heat and smoke hatch with 165 degree fusible link.

ModelNo.M-1RB-1RBS-1RC-1RCS-1RD-1M-3x3RCS-3x3RD-3x3M-7RB-4x4RBS-4x4M-2RB-2RBS-2RC-2RCS-2RD-2M-3RB-3RBS-3RC-3RCS-3RD-3

ModelNo.RB-4RC-4RD-4RB-5RC-5RD-5RC-6RD-6

ModelNo.RBS-SRDS-S

SINCE 1902

All information is subject to change without notice. Dimensions and specifications shown are within manufacturing tolerances.© Copyright, January 2008, Commercial Products Group of Hart & Cooley, Inc. All Rights Reserved.

Guide SpecificationMilcor single leaf roof hatches with thespring mounted in cover includes models:M, RCS, RBS, and RD-1. Sizes and otherproperties are as indicated on pages 4 and8-9.

FrameM Models: 14-gauge prime-paintedgalvanized steel, with a 12" high curb,integral counterflashing, 3-1/2" widemounting flanges with pre-drilled holes,and 1" exterior fiberboard insulation.

RCS and RBS Models: 16-gauge prime-painted galvanized steel with a 12" highcurb, integral counterflashing, 3-1/2” widemounting flanges with pre-drilled holes,and 1" exterior fiberboard insulation.

RD-1 Model: Mill finish .090 aluminumwith a 12" high curb, integralcounterflashing, 3-1/2" wide mountingflanges with pre-drilled holes, and 1"exterior fiberboard insulation.

CoversM Model: High-strength, composite panelswith 14-gauge prime-painted galvanizedsteel, 22-gauge galvanized steel linerbonded to core of 1" rigid foam-typeinsulation.

RCS and RBS Model: Composite panelswith 18-gauge prime-painted galvanizedsteel exterior and 22-gauge prime-paintedgalvanized steel liner (RBS Style), or .063aluminum exterior and .063 aluminumliner, bonded to a 1" rigid foam-typeinsulation (RCS Style).

RD Model: Composite panels with 11-gauge aluminum (.090 aluminum) and .063aluminum liner bonded to a core of 1" rigidstyrofoam insulation.

Torsion BarCover operation is assisted by a torsionbar mounted within the confines of thecover.

Cover MountingCovers are mounted on steel pintle hinges,complete with closed-cell rubber weatherseal, automatic locking hold-open arms,inside and outside latching devices,handles and inside padlock hasp.

HardwareAll hardware is zinc or cadmium plated.

Single Leaf: SpringMounted in Cover

Single Leaf: SpringMounted in Frame

Guide SpecificationMilcor single leaf roof hatches with thespring mounted in frame includes models:M, RB, RBS, RC, RCS, RD and RDS. Sizesand other properties are as indicated onpages 5 and 8-9.

FrameM, RC and RB Models: 14-gauge, prime-painted galvanized steel, with a 12" highcurb, integral counterflashing, 3-1/2" widemounting flange with pre-drilled holes, and1" exterior fiberboard insulation.

RBS and RCS Models: 16-gauge prime-painted galvanized steel, with a 12" highcurb, integral counterflashing, 3-1/2" widemounting flanges with pre-drilled holes,and 1" exterior fiberboard insulation.

RD and RDS-S Models: Mill finish 11-gauge (.090 aluminum), with a 12" highcurb, integral counterflashing, 3-1/2" widemounting flanges with pre-drilled holes,and 1" exterior fiberboard insulation.

CoversM and RB Models: High-strength panelswith 14-gauge, prime-painted steel exteriorand 22-gauge galvanized steel linerbonded to core of 1" rigid foam-type (MStyle) or 1” fiberglass insulation (RB Style).

RBS and RCS Models: Composite designpanels with 18-gauge prime-paintedgalvanized steel exterior and 22-gaugeprime painted steel liner (RBS Model), or.063 aluminum exterior and .063 aluminumliner bonded to a 1" core of rigid styrofoaminsulation.

RD and RC Models: Mill finish 11-gaugealuminum (.090 aluminum) exterior with.063 aluminum liner and 1” fiberglassinsulation.

Torsion SpringCover operation is assisted by enclosedheavy-duty torsion spring operatorsattached to the curb frame.

Cover MountingCovers are mounted on steel pintle hinges,complete with closed-cell rubber weatherseal, automatic locking hold-open arms,inside and outside latching devices,handles and inside padlock hasp.

HardwareAll hardware is zinc or cadmium plated.

Guide SpecificationMilcor double leaf roof hatches withsprings mounted in the frame. Includesmodels: RB, RC, and RD. Sizes and otherproperties are as indicated on pages 6and 8-9.

FrameRB and RC Models: 14-gauge prime-painted galvanized steel with a 12" highcurb, integral counterflashing, 3-1/2" widemounting flanges with pre-drilled holes,and 1" exterior fiberboard insulation.

RD Models: Mill finish 11-gauge (.090aluminum) with a 12" high curb, integralcounterflashing, 3-1/2" wide mountingflanges with pre-drilled holes, and 1"exterior fiberboard insulation.

CoversRB Models: High-strength panels with14-gauge, prime-painted steel exteriorand 22-gauge galvanized steel linerbonded to 1” fiberglass insulation.

RD and RC Models: Mill finish 11-gaugealuminum (.090 aluminum) exterior with.063 aluminum liner with 1” fiberglassinsulation.

Torsion SpringCover operation is assisted by enclosedheavy-duty coil spring operators attachedto the curb frame.

Cover MountingCovers are mounted with astragal designon steel pintle hinges and are completewith a closed-cell rubber weather seal atdouble door closure and frame, automaticlocking hold-open arms, and a two-pointlatch system for tight, secure closure withinside and outside handles and an insidepadlock hasp.

HardwareAll hardware is zinc or cadmium plated.

Double Leaf: SpringMounted in Frame

Roof Hatch Technical SpecsTechnical Product Information

SINCE 1902

All information is subject to change without notice. Dimensions and specifications shown are within manufacturing tolerances.© Copyright, January 2008, Commercial Products Group of Hart & Cooley, Inc. All Rights Reserved.

• Vent for Heat and SmokeDesigned to automatically spring open to approximately90 degrees in the event of a fire.

Heat and smoke vents can save lives by releasing smoke,decreasing the possibility of deadly smoke inhalation tobuilding occupants. The open covers permit firefighters todouse flames directly from the rooftop location.

The covers are activated by the parting of a single ULlisted, FM approved 165°F fusible link, and automaticallylock in the fully open position. Units can be equipped withelectrical links that trigger the cover opening whenconnected to a remote smoke or fire alarm.

• Open Against Snow or WindCovers are of double-leaf construction, with each leafequipped with torsion spring operators of sufficientstrength to open against a minimum 10 psf snow or windload.

• No Over-TravelUnits are equipped with hydraulic shock absorbers tocontrol opening speed and prevent over-travel.

• No Accidental OpeningCovers will not open when subjected to a minimum 30 psfuplift pressure. This prevents accidental openings.

• Fire SafetyComplies with the requirements of a Class “A” burningbrand (UL 790).

• Easy ResetCovers latch automatically. Manual release mechanismresets automatically when covers are closed from theroof line.

• Thermal EfficiencyInsulated covers provide a minimum thermal transmit-tance value of U = 0.093 to reduce heat loss or gain andto prevent condensation.

• Weathertight PerformanceCovers are fully gasketed for weathertight performance.The dual covers close unto a fixed channel that permitswater to flow off the unit without interfering with the coveroperation.

• Choice of MaterialsMost Milcor heat and smoke vents are available in threecombinations of materials to meet specific design criteria:• All Galvanized• All Aluminum• Aluminum Cover/Galvanized Curb

Fusible LinksWhile the standard is a 165o UL Listed fusible link, for environmentsrequiring different melt temperatures, Milcor offers fusible linksdesigned for temperatures up to 360o.

McCabe LinkThis is a multipurpose, dual-responsive and repositioning link whichreacts when subject to heat and electrical current. (Electro-ThermalLink). Available in 24 volt and 120 volt.

Explosion VentsSmoke Vents can be equipped to operate as explosion vents.

Motorized or Manual Winch OperationSmoke vents can be equipped with motor operators for opening andclosing the covers from a remote 3-position selector switch.

Metal Roof Curb MountsCurbs can be modified to fit most standard metal roof profiles.

Sloped To Maintain Level OperationCurbs can be sloped to match roof slopes providing a level surfacewhen units are installed.

Popular Smoke Vent Options

Overall Product Benefits

Heat & Smoke VentsTechnical Product Information

SINCE 1902

All information is subject to change without notice. Dimensions and specifications shown are within manufacturing tolerances.© Copyright, January 2008, Commercial Products Group of Hart & Cooley, Inc. All Rights Reserved.

Low Profile: 4'0" and 4'6" and Big Smoky® 5'0", 5'6" & 6'0"

Milcor Heat & Smoke Vents ProtectIn the Event of Smoke & Fire

Opens instantly when UL listed fusible link is exposed to atemperature of 165° to release noxious smoke and deadly gasesout of the building.

• Vent for Heat and SmokeCovers automatically spring open to approximately90 degrees in the event of fire and automaticallylock in fully open position.

• Big Smoky® = Fewer UnitsWith UL/FM approved sizes up to 6’0” x 12’0”, fewerunits are required. Meets code requirements whilesaving costs and reducing the number of rooftoppenetrations.

• Open Against Snow or WindCovers are constructed with sufficient torsion springoperators to open against a minimum 10 psf snowor wind load.

• No Over-TravelUnits are equipped with hydraulic shock absorbersto control opening speed and prevent over-travel.

• No Accidental OpeningCovers will not open when subjected to a minimumuplift pressure of 30 psf, preventing accidentalopening.

• Easy ResetCovers latch automatically and manual releasemechanism resets automatically by closing covers.

• High Thermal EfficiencyInsulated cover reduces heat loss or gain andprevents condensation.

• Fire SafetyComplies with the requirements of Class “A” burning brand test(UL 790).

• UL/ FM TestedMilcor models U-LP, U-LPA, or U-LPAG automatically operatingheat and smoke vents are tested and listed by Underwriter’sLaboratories, Inc. and Factory Mutual Research Corporation.

• Choice of MaterialsVents are available in three combinations of materials to meetspecific design criteria.

U-LP: All GalvanizedU-LPA: All AluminumU-LPAG: Aluminum Cover /Galvanized Curb

Heat & Smoke VentsTechnical Product Information

Distributed by: BEST MATERIALS LLC, Phoenix AZ602-272-8128 800-474-7570 www.bestmaterials.com

SINCE 1902

All information is subject to change without notice. Dimensions and specifications shown are within manufacturing tolerances.© Copyright, January 2008, Commercial Products Group of Hart & Cooley, Inc. All Rights Reserved.

Low ProfileBig Smoky®

Counterflashing

Opening width

Curb with fiberboardinsulation on exterior

31/2"

131/2"

Hydraulic shockabsorber

1” Rigid Composite Design Cover

Counterflashing

Opening width

Curb with fiberboardinsulation on exterior

31/2"

131/2"

Hydraulic shockabsorber

2” Rigid Foam Composite Design Cover

Standard Sizes and Model Number(Second dimension is for length on hinge side.)

Galvanized Steel Aluminum Aluminum Cover &Galvanized Curb

Sizes4'0" x 4'0"4'0" x 5'0"4'0" x 6'0"4'0" x 7'0"4'0" x 7'6"4'0" x 8'0"4'6" x 4'0"4'6" x 5'0"4'6" x 6'0"5'0" x 5'0"5'0" x 6'0"5'0" x 7'0"5'0" x 8'0"5'0" x 9'0"5'0" x 10'0"5'0" x 11'0"5'0" x 12'0"5'6" x 6'0"5'6" x 7'0"5'6" x 8'0"5'6" x 9'0"5'6" x 10'0"5'6" x 11'0"5'6" x 12'0"6'0" x 6'0"6'0" x 7'0"6'0" x 8'0"6'0" x 9'0"6'0" x 10'0"6'0" x 11'0"6'0" x 12'0"

Model No. Lbs.U-LP-4848 275U-LP-4860 325U-LP-4872 375U-LP-4884 425U-LP-4890 450U-LP-4896 475U-LP-5448 300U-LP-5460 360U-LP-5472 420U-LP-6060 385U-LP-6072 460U-LP-6084 530U-LP-6096 590U-LP-60108 650U-LP-60120 720U-LP-60132 800U-LP-60144 860U-LP-6672 500U-LP-6684 570U-LP-6696 640U-LP-66108 730U-LP-66120 800U-LP-66132 870U-LP-66144 940U-LP-7272 540U-LP-7284 620U-LP-7296 720U-LP-72108 790U-LP-72120 860U-LP-72132 940U-LP-72144 1010

Model No. Lbs.U-LPA-4848 205U-LPA-4860 241U-LPA-4872 284U-LPA-4884 327U-LPA-4890 336U-LPA-4896 359U-LPA-5448 225U-LPA-5460 270U-LPA-5472 320U-LPA-6060 285U-LPA-6072 350U-LPA-6084 405U-LPA-6096 450U-LPA-60108 495U-LPA-60120 550U-LPA-60132 608U-LPA-60144 655U-LPA-6672 380U-LPA-6684 435U-LPA-6696 487U-LPA-66108 555U-LPA-66120 610U-LPA-66132 662U-LPA-66144 715U-LPA-7272 411U-LPA-7284 472U-LPA-7296 548U-LPA-72108 601U-LPA-72120 654U-LPA-72132 715U-LPA-72144 768

Model No. Lbs.U-LPAG-4848 250U-LPAG-4860 312U-LPAG-4872 337U-LPAG-4884 385U-LPAG-4890 407U-LPAG-4896 430

- -- -- -

U-LPAG-6060 368U-LPAG-6072 414U-LPAG-6084 483U-LPAG-6096 530U-LPAG-60108 596U-LPAG-60120 647U-LPAG-60132 720U-LPAG-60144 774U-LPAG-6672 455U-LPAG-6684 531U-LPAG-6696 583U-LPAG-66108 655U-LPAG-66120 712U-LPAG-66132 792U-LPAG-66144 847U-LPAG-7272 496U-LPAG-7284 579U-LPAG-7296 636U-LPAG-72108 715U-LPAG-72120 776U-LPAG-72132 863U-LPAG-72144 910

ModelLow ProfileLow ProfileLow ProfileLow ProfileLow ProfileLow ProfileLow ProfileLow ProfileLow ProfileLow ProfileBig Smoky®Big Smoky®Big Smoky®Big Smoky®Big Smoky®Big Smoky®Big Smoky®Big Smoky®Big Smoky®Big Smoky®Big Smoky®Big Smoky®Big Smoky®Big Smoky®Big Smoky®Big Smoky®Big Smoky®Big Smoky®Big Smoky®Big Smoky®Big Smoky®

Clear Opening

Big Smoky® Low Profile

Heat & Smoke VentsTechnical Product Information

SINCE 1902

All information is subject to change without notice. Dimensions and specifications shown are within manufacturing tolerances.© Copyright, January 2008, Commercial Products Group of Hart & Cooley, Inc. All Rights Reserved.

U-LP Acoustical: STC-40 and STC-45

nnnnn Low Profile- 4’0”, 5'0", 5'6" & 6'0" Clear Opening Width

• Dual BenefitSTC-40 and STC-45 vents provide the dual benefit offire safety and protection from noise penetrationthrough the roof assembly.

• Typical ApplicationsUsed over auditoriums and stage areas, near airports orwhere outside noise may affect the environment insidethe building.

• Open Against Snow or WindCovers are constructed with sufficient torsion springoperators to open against a minimum 10 psf snow orwind load.

• No Over-TravelUnits are equipped with hydraulic shock absorbers tocontrol cover opening speed and prevent over travel.

• No Accidental OpeningCovers will not open when subjected to minimum upliftpressure of 30 psf, preventing accidental opening.

• Fire SafetyCovers automatically spring open in the event of fireand automatically lock in fully open position.

• Easy ResetCovers latch automatically and manual releasemechanism resets automatically by closing covers.

• UL/ FM TestedModels are approved by Factory Mutual ResearchCorporation.

• MaterialsGalvanized Steel (FM Approved)

Standard Sizes and Model NumberAcoustical (ULP STC-40 & STC-45) Galvanized Steel(Second dimension is for length on hinge side.)

STC-40 STC-45ClearOpeningSize4'0" x 4'0"

4'0" x 5'0"

4'0" x 6'0"

4'0" x 7'0"

4'0" x 8'0"

5'0" x 6'0"

5'0" x 7'0"

5'0" x 8'0"

5'0" x 9'0"

5'0" x 10'0"

5'0" x 11'0"

5'0" x 12'0"

5'6" x 6'0"

5'6" x 7'0"

5'6" x 8'0"

5'6" x 9'0"

5'6" x 10'0"

5'6" x 11'0"

5'6" x 12'0"

6'0" x 6'0"

6'0" x 7'0"

6'0" x 8'0"

6'0" x 9'0"

6'0" x 10'0"

6'0" x 11'0"

6'0" x 12'0"

Model No. Lbs.U-LP STC-40-4848 910

U-LP STC-40-4860 935

U-LP STC-40-4872 960

U-LP STC-40-4884 990

U-LP STC-40-4896 1040

U-LP STC-40-6072 1030

U-LP STC-40-6084 1100

U-LP STC-40-6096 1185

U-LP STC-40-60108 1255

U-LP STC-40-60120 1400

U-LP STC-40-60132 1530

U-LP STC-40-60144 1662

U-LP STC-40-6672 1050

U-LP STC-40-6684 1130

U-LP STC-40-6696 1250

U-LP STC-40-66108 1380

U-LP STC-40-66120 1530

U-LP STC-40-66132 1675

U-LP STC-40-66144 1830

U-LP STC-40-7272 1100

U-LP STC-40-7284 1210

U-LP STC-40-7296 1330

U-LP STC-40-72108 1500

U-LP STC-40-72120 1682

U-LP STC-40-72132 1830

U-LP STC-40-72144 1995

Model No. Lbs.U-LP STC-45-4848 955

U-LP STC-45-4860 980

U-LP STC-45-4872 1005

U-LP STC-45-4884 1040

U-LP STC-45-4896 1095

U-LP STC-45-6072 1080

U-LP STC-45-6084 1155

U-LP STC-45-6096 1245

U-LP STC-45-60108 1320

U-LP STC-45-60120 1470

U-LP STC-45-60132 1605

U-LP STC-45-60144 1745

U-LP STC-45-6672 1100

U-LP STC-45-6684 1185

U-LP STC-45-6696 1310

U-LP STC-45-66108 1450

U-LP STC-45-66120 1605

U-LP STC-45-66132 1750

U-LP STC-45-66144 1920

U-LP STC-45-7272 1155

U-LP STC-45-7284 1270

U-LP STC-45-7296 1395

U-LP STC-45-72108 1575

U-LP STC-45-72120 1756

U-LP STC-45-72132 1920

U-LP STC-45-72144 2095

Heat & Smoke VentsTechnical Product Information

SINCE 1902

All information is subject to change without notice. Dimensions and specifications shown are within manufacturing tolerances.© Copyright, January 2008, Commercial Products Group of Hart & Cooley, Inc. All Rights Reserved.

Dual LatchAssembly

14ga.Galvanizedsteel liner

AcousticalGasket

165° Fusible Link

Extension Spring22ga.Galvanized SteelLiner& 14ga. Galvanized Liner

DownswingBottom Covers

Liner 22ga.Galvanized

Shock Absorber

Latch

2"FiberglassInsulation

51/2"

20"

Heavy- dutyTorsion Spring

22ga.Galvanized Steel Liner

2" Styrofoam Insulation5/8" Diameter Pivot PinsPintle Hinge

Cover 14ga.Galvanized

2" StyrofoamInsulation

STC- 40

STC- 45

STC-45 Heat and Smoke Vents carry a STC (SoundTransmission Coefficient of 45 when tested inaccordance with ASTM: E90(90). The higher the STCnumber the better the sound blocking performance.

STC-40 Heat and Smoke Vents carry a STC (SoundTransmission Coefficient of 40 when tested inaccordance with ASTM: E90(90). The higher the STCnumber the better the sound blocking performance.

STC-45 top and bottom double doorsprovide maximum sound and thermalinsulating values.

Heat & Smoke VentsTechnical Product Information

Liner22ga.Galvanized

2" Styrofoam Insulation

Gutter InsulationSame As Curb

Inside Manual Release

Heavy-dutyTorsion Spring

Dual Latch Assembly151/2"

AcousticalBarrier

2" Fiberglass Insulation

Pintle Hinge

5/8" DiameterPivot Pins

Shock Absorber

14ga. GalvanizedSteel Liner

2" Fiberglass InsulationCover 14ga.Galvanized

Extension Springs & Fusible Link Assembly

AcousticalGasket

22ga.GalvanizedSteel Liner

41/2"

SINCE 1902

All information is subject to change without notice. Dimensions and specifications shown are within manufacturing tolerances.© Copyright, January 2008, Commercial Products Group of Hart & Cooley, Inc. All Rights Reserved.

UL-SKY Low Profile Smoke Vents

Fusible Link

Manual Release

Curb 16ga. Galv.

Aluminum FrameWeather SealPolycarbonate FlatPanel

Hydraulic ShockAbsorber

Torsion Spring

Clear Opening Width31/2" 31/2"

131/2"Counter-flashing16ga.Galv.

• Vent for Heat and SmokeIn the event of fire, covers automatically springopen to approximately 90 degrees when fusiblelink melts and automatically lock in fully openposition.

• Provides Interior LightSturdy polycarbonate covers admit light to areasbeneath the roof. A variety of shading optionsare available.

• Withstand High ImpactTesting proved their ability to withstand 400ft/lbof impact without puncturing or cracking thepanels.

• UV StableSturdy cover panels allow light to areas beneaththe roof and provide long term resistance toultraviolet light.

• Open Against Snow or WindCovers are manufactured with ample torsionspring operators to open against a minimum 10psf snow or wind load.

• No Over-TravelUnits are equipped with hydraulic shockabsorbers to control opening speed and preventover-travel.

• No Accidental OpeningCovers will not open when subjected to aminimum uplift pressure of 30 psf, preventingaccidental opening.

• Easy ResetCovers latch automatically and manual releasemechanism resets automatically byclosing covers.

• Choices Available Available with aluminum or galvanized curb inwidths from 4’ to 6’ and lengths from 4’ to 8’.

Standard Sizes and Model Number(Second dimension is for length on hinge side.)

Galvanized Steel Curb AluminumModel No. Lbs.UL-SKY-4848 284UL-SKY-4860 337UL-SKY-4872 390UL-SKY-4884 443UL-SKY-4896 496UL-SKY-5448 311UL-SKY-5460 364UL-SKY-5472 417UL-SKY-5484 470UL-SKY-5496 523UL-SKY-6048 337UL-SKY-6060 390UL-SKY-6072 443UL-SKY-6084 496UL-SKY-6096 549UL-SKY-6648 364UL-SKY-6660 417UL-SKY-6672 470UL-SKY-6684 523UL-SKY-6696 576UL-SKY-7248 390UL-SKY-7260 443UL-SKY-7272 496UL-SKY-7284 549UL-SKY-7296 602

Model No. Lbs.UL-SKYA-4848 202UL-SKYA-4860 240UL-SKYA-4872 278UL-SKYA-4884 316UL-SKYA-4896 354UL-SKYA-5448 221UL-SKYA-5460 259UL-SKYA-5472 297UL-SKYA-5484 335UL-SKYA-5496 373UL-SKYA-6048 240UL-SKYA-6060 278UL-SKYA-6072 316UL-SKYA-6084 354UL-SKYA-6096 391UL-SKYA-6648 259UL-SKYA-6660 297UL-SKYA-6672 335UL-SKYA-6684 373UL-SKYA-6696 410UL-SKYA-7248 278UL-SKYA-7260 316UL-SKYA-7272 354UL-SKYA-7284 391UL-SKYA-7296 429

ClearOpening Size

4'0" x 4'0"4'0" x 5'0"4'0" x 6'0"4'0" x 7'0"4'0" x 8'0"4'6" x 4'0"4'6" x 5'0"4'6" x 6'0"4'6" x 7'0"4'6" x 8'0"5'0" x 4'0"5'0" x 5'0"5'0" x 6'0"5'0" x 7'0"5'0" x 8'0"5'6" x 4'0"5'6" x 5'0"5'6" x 6'0"5'6" x 7'0"5'6" x 8'0"6'0" x 4'0"6'0" x 5'0"6'0" x 6'0"6'0" x 7'0"6'0" x 8'0"

Heat & Smoke VentsTechnical Product Information

nnnnn Low Profile 4’0”, 4’ 6”, 5'0", 5'6" & 6'0" Clear Opening Width

SINCE 1902

All information is subject to change without notice. Dimensions and specifications shown are within manufacturing tolerances.© Copyright, January 2008, Commercial Products Group of Hart & Cooley, Inc. All Rights Reserved.

UL-SEE Domed Smoke Vents

• Vent for Heat and SmokeUL-SEE Dome-shaped vents open instantly in theevent of a fire and automatically lock in fully openposition.

• Interior Light SourceSturdy polycarbonate domes allow light to areasbeneath the roof and provide long term resistance toultraviolet light. A variety of shading options areavailable.

• Design Deters CondensationAir barrier between both inner and outer domes, detersthe risk of interior condensation.

• Reduced ImpactSloped dome profile provides reduced impact of snowloads and provides water run-off.

• Open Against Snow or WindCovers are manufactured with ample torsion springoperators to open against a minimum 10 psf snow orwind load.

• No Over-TravelUnits are equipped with hydraulic shock absorbers tocontrol opening speed and prevent over-travel.

• No Accidental OpeningCovers will not open when subjected to a minimumuplift pressure of 30 psf, preventing accidental opening.

• Easy ReleaseVent design allows covers to be released manuallyfrom inside or outside without disturbing the fusible linkassembly.

• Easy ResetCovers latch automatically and manual releasemechanism resets automatically by closing covers.

• UL/ FM TestedMilcor UL-SEE automatically operating heat and smokevents are tested and listed by Underwriter’s Laborato-ries, Inc. and Factory Mutual Research Corporation.

Standard Sizes and Model Number(Second dimension is for length on hinge side.)

ClearOpening Size

4'0" x 4'0"4'0" x 5'0"4'0" x 6'0"4'0" x 7'0"4'0" x 8'0"4'6" x 4'0"4'6" x 5'0"4'6" x 6'0"4'6" x 7'0"4'6" x 8'0"5'0" x 4'0"5'0" x 5'0"5'0" x 6'0"5'0" x 7'0"5'0" x 8'0"5'6" x 4'0"5'6" x 5'0"5'6" x 6'0"5'6" x 7'0"5'6" x 8'0"6'0" x 4'0"6'0" x 5'0"6'0" x 6'0"6'0" x 7'0"6'0" x 8'0"

Galvanized Steel Curb AluminumModel No.UL-SEEA-4848UL-SEEA-4860UL-SEEA-4872UL-SEEA-4884UL-SEEA-4896UL-SEEA-5448UL-SEEA-5460UL-SEEA-5472UL-SEEA-5484UL-SEEA-5496UL-SEEA-6048UL-SEEA-6060UL-SEEA-6072UL-SEEA-6084UL-SEEA-6096UL-SEEA-6648UL-SEEA-6660UL-SEEA-6672UL-SEEA-6684UL-SEEA-6696UL-SEEA-7248UL-SEEA-7260UL-SEEA-7272UL-SEEA-7284UL-SEEA-7296

Model No.UL-SEE-4848UL-SEE-4860UL-SEE-4872UL-SEE-4884UL-SEE-4896UL-SEE-5448UL-SEE-5460UL-SEE-5472UL-SEE-5484UL-SEE-5496UL-SEE-6048UL-SEE-6060UL-SEE-6072UL-SEE-6084UL-SEE-6096UL-SEE-6648UL-SEE-6660UL-SEE-6672UL-SEE-6684UL-SEE-6696UL-SEE-7248UL-SEE-7260UL-SEE-7272UL-SEE-7284UL-SEE-7296

Lbs.240285330370420265320355430480300355400455520335390440500565370425475545630

Lbs.240285330370420265320355430480300355400455520335390440500565370425475545630

Weather Seal

AluminumExtrusionFrame

PolycarbonateOptional:Polycaronate InnerDomeHydraulic ShockAbsorber

CounterFlashing Curb Manual

ReleaseTorsionSpring

31/2"31/2" Clear Opening

Fusible Link

Heat & Smoke VentsTechnical Product Information

nnnnn Low Profile 4’0”, 4’ 6”, 5'0", 5'6" & 6'0" Clear Opening Width

Distributed by: BEST MATERIALS LLC, Phoenix AZ602-272-8128 800-474-7570 www.bestmaterials.com

SINCE 1902

All information is subject to change without notice. Dimensions and specifications shown are within manufacturing tolerances.© Copyright, January 2008, Commercial Products Group of Hart & Cooley, Inc. All Rights Reserved.

Guide SpecificationMilcor models: U-LP, U-LPA, or U-LPAGautomatically operating heat and smokevents are listed by UnderwritersLaboratories, Inc. and Factory MutualResearch Corporation. Sizes are asindicated on page 13.

FrameWelded 13-1/2" height, (16-gaugegalvanized steel (U-LP and U-LPAG), or.090 aluminum (U-LPA) curb completewith 3-1/2" pre-drilled mounting flangesand same gauge counterflashing, and 1"thick exterior fiberboard insulation.

CoversHigh-strength composite constructionwith exterior cover and liner 22-gaugegalvanized steel (U-LP), or .063aluminum (U-LPA and U-LPAG), bondedto a 2" core of rigid foam-type insulationcomplying with the requirements of Class“A” Burning brand test (UL-790) andproviding a minimum thermal transmit-tance value of U = 0.093 to detercondensation and reduce heat loss.

Operation• Covers automatically spring open toapproximately 90 degrees in the event offire, being actuated by the parting of asingle UL-listed and FM approved 165°Ffusible link, automatically locking in thefully open position.

• Covers are of double-leaf construction,with each leaf equipped with sufficienttorsion spring operators to open againsta 10 psf snow or wind load.

• Units are equipped with hydraulicshock absorbers to control cover openingspeed and prevent over-travel.

• Covers will not open when subjected toa 30 psf uplift pressure.

• Vent design allows covers to bereleased manually from inside or outsidewithout disturbing the fusible linkassembly.

• Covers latch automatically and manualrelease mechanism resets automaticallyby closing covers.

Big Smoky®Heat & Smoke Vent

Guide SpecificationMilcor models: U-LP, U-LPA, or U-LPAGautomatically operating heat and smokevents are listed by UnderwritersLaboratories, Inc. and Factory MutualResearch Corporation. Sizes are asindicated on page 13.

FrameWelded 13-1/2" height, (16-gaugegalvanized steel (U-LP and U-LPAG), or.090 aluminum (U-LPA) curb completewith 3-1/2" pre-drilled mounting flangesand same gauge counterflashing, and 1"thick exterior fiberboard insulation.

CoversHigh-strength composite constructionwith exterior cover and liner 22-gaugegalvanized steel (U-LP), or .063aluminum (U-LPA and U-LPAG), bondedto a 1" core of rigid foam-type insulationcomplying with the requirements of Class“A” Burning brand test (UL-790) andproviding a minimum thermal transmit-tance value of U = 0.173 to detercondensation and reduce heat loss.

Operation• Covers automatically spring open toapproximately 90 degrees in the event offire, being actuated by the parting of asingle UL-listed and FM approved 165°Ffusible link, automatically locking in thefully open position.

• Covers are of double-leaf construc-tion, with each leaf equipped withsufficient torsion spring operators toopen against a 10 psf snow or wind load.

• Units are equipped with hydraulicshock absorbers to control cover openingspeed and prevent over-travel.

• Covers will not open when subjected toa 30 psf uplift pressure.

• Vent design allows covers to bereleased manually from inside or outsidewithout disturbing the fusible linkassembly.

• Covers latch automatically and manualrelease mechanism resets automaticallyby closing covers.

Low ProfileHeat & Smoke Vent

Guide SpecificationMilcor Acoustical ULP-STC-40 automati-cally operating heat and smoke ventscarry a STC-40 acoustical rating and arelisted by Factory Mutual ResearchCorporation. Sizes are as indicated onpages 14 and 15.

FrameWelded 15-1/2" height, 14-gaugegalvanized steel curb complete with3-1/2" pre-drilled mounting flanges,same gauge counterflashing and 2" thickfiberglass acoustical insulation protectedby a 22-gauge galvanized steel liner.

Covers14-gauge galvanized exterior and 22-gauge galvanized interior liners divideacoustical insulation consisting of 2"fiberglass insulation, 1" dead air spaceand 2" rigid foam insulation with a 1/8”acoustical barrier. Acoustical gasketbetween cover and frame.

Operation• Covers automatically spring open toapproximately 90 degrees in the event offire, actuated by the parting of a singleUL-listed 165°F fusible link, andautomatically lock fully open.

• Covers are of double-leaf construction,with each leaf equipped with sufficienttorsion spring operators to open againsta 10 psf snow or wind load.

• Units are equipped with hydraulicshock absorbers to control coveropening speed and prevent over-travel.

• Covers will not open when subjectedto uplift pressure up to 30 psf.

• Vent design allows covers to bereleased manually from inside or outsidewithout disturbing the fusible linkassembly. Manual release available onstandard units only. Eliminated on ventswith optional special releases. ConsultMilcor Customer Service for special unitrequirements.

• Covers latch automatically and manualrelease mechanism resets automaticallyby closing covers.

STC-40 AcousticalHeat & Smoke Vent

NOTE:1. 14-gauge frame and coveravailable on special order for all sizes and styles of Big Smoky® and Low Profile Units.2. Call Milcor for information on other available options, such as painting, electro-thermal links, winches, other fusible linktemperatures, metal roof applications, etc.

Heat & Smoke Technical SpecsTechnical Product Information

SINCE 1902

All information is subject to change without notice. Dimensions and specifications shown are within manufacturing tolerances.© Copyright, January 2008, Commercial Products Group of Hart & Cooley, Inc. All Rights Reserved.

Guide SpecificationMilcor Acoustical ULP-STC-45 automati-cally operating heat and smoke ventscarry a STC-45 acoustical rating and areFactory Mutual approved. Sizes are asindicated on pages 14 and 15.

FrameWelded 20" height, 14-gauge galvanizedsteel curb complete with 5-1/2" pre-drilled mounting flanges and same gaugecounterflashing. A layer of 1” sheetrockand 2” fiberglass insulation is fullycovered and protected by a 22-gaugegalvanized steel liner to provide excellentsound deadening.

CoversUpper covers are 14-gauge galvanizedsteel. Acoustical insulation on uppercovers is rigid foam 2" in thickness fullybonded and protected by a 22-gaugegalvanized steel cover liner. Lowercovers are continuously hinged and are14-gauge galvanized steel. Acousticalinsulation in the lower covers is fullycovered and protected by a 22-gaugegalvanized liner.

Operation• Covers automatically spring open toapproximately 90 degrees in the event offire, actuated by the parting of a singleUL-listed 165°F fusible link, andautomatically lock in fully open position.

• Upper covers are of double-leafconstruction, equipped with sufficienttorsion spring operators to open againsta 10 psf snow or wind load. Lower coversrelease and swing down when link isbroken.

• Units are equipped with hydraulicshock absorbers to control cover openingspeed and prevent over-travel.

• Covers will not open when subjected touplift pressure up to 30 psf.

• Vent design allows covers to bereleased manually from inside or outsidewithout disturbing the fusible linkassembly. Manual release available onstandard units only. May require deletionon vents with optional special releases orwinches.

• Covers latch automatically and manualrelease mechanism resets automaticallyby closing covers. Bottom covers mustbe manually latched.

STC-45 AcousticalHeat & Smoke Vent

Guide SpecificationMilcor UL-SKY automatically operatingheat and smoke vents. Sizes are asindicated on page 16.

FrameWelded 13-1/2" height, 16-gaugegalvanized steel (UL-SKY), or .090aluminum (UL-SKYA) curb complete with3-1/2" pre-drilled mounting flanges andsame gauge counterflashing, and 1"thick exterior insulation.

CoversDamage resistant, light admitting,polycarbonate panels surrounded by anextruded aluminum frame. Consult Milcorfor tint options that are available.

Operation• Covers automatically spring open toapproximately 90 degrees in the event offire, actuated by the parting of a singleUL-listed 165°F fusible link, andautomatically lock fully open.

• Covers are of double-leaf construction,with each leaf equipped with sufficienttorsion spring operators to open againsta 10 psf snow or wind load.

• Testing proves covers will support 400ft/lb of impact.

• Units are equipped with hydraulicshock absorbers to control cover openingspeed and prevent over-travel.

• Covers will not open when subjected touplift pressure up to 30 psf.

• Vent design allows covers to bereleased manually from inside or outsidewithout disturbing the fusible linkassembly.

• Covers latch automatically and manualrelease mechanism resets automaticallyby closing covers.

UL-SKY Flat Panel SkylightHeat and Smoke Vent

Guide SpecificationMilcor UL-SEE automatically operatingheat and smoke vents are listed byUnderwriters Laboratories, Inc. andFactory Mutual Research Corporation.Sizes are as indicated on page 17.

FrameWelded 13-1/2" height, 16-gaugegalvanized steel (UL-SEE), or .090aluminum (UL-SEEA) curb complete with3-1/2" pre-drilled mounting flanges andsame gauge counterflashing, and 1"thick exterior insulation.

CoversDamage resistant, light admitting,polycarbonate outer dome with 1/8"polycarbonate inner dome, surroundedby an extruded aluminum frame. ConsultMilcor for tint options that are available.

Operation• Covers automatically spring open toapproximately 90 degrees in the event offire, actuated by the parting of a singleUL-listed 165°F fusible link, andautomatically lock fully open.

• Covers are of double-leaf construction,with each leaf equipped with sufficienttorsion spring operators to open againsta 10 psf snow or wind load.

• Units are equipped with hydraulicshock absorbers to control cover openingspeed and prevent over-travel.

• Covers will not open when subjected touplift pressure up to 30 psf.

• Vent design allows covers to bereleased manually from inside or outsidewithout disturbing the fusible linkassembly.

• Covers latch automatically and manualrelease mechanism resets automaticallyby closing covers.

UL-SEE Domed SkylightHeat & Smoke Vent

Heat & Smoke Technical SpecsTechnical Product Information

SINCE 1902

All information is subject to change without notice. Dimensions and specifications shown are within manufacturing tolerances.© Copyright, January 2008, Commercial Products Group of Hart & Cooley, Inc. All Rights Reserved.

Heavy-Duty Construction to MeetRequired LoadsSolid framing and anchoring designs and options in bothaluminum or steel construction can handle demandingapplications for foot or vehicle traffic safely.

Stainless Steel HardwareFor installation in highly corrosive environments, roofhatches are available with stainless steel hardware.

Overall Product Features

Floor & Sidewalk DoorsTechnical Product Information

Sidewalk DoorsFor Exterior Access Applications orWhere Interior Moisture ConditionsRequire Drainage Provisions.

Floor DoorsFor Interior Access To Valves, Electrical orComputer Wiring, or For Access To Upperor Lower Floor Levels.

Locking and Latching DoorsWhere addtional security is needed, floor and sidewalk doorsare available with mortise cylinder locks and recessed padlockhasps. Contact the factory for other lock and latching options.

Special Wheel LoadingGA and GD style sidewalk doors are available with H-10 andH-20 wheel loading. They are designed for off-street usewhere not subjected to high volume traffic.

Milcor Floor &Sidewalk Doors Are

Built To BeDependable

and Long-Lasting

DoubleLeafStyle

SingleLeafStyle

SINCE 1902

All information is subject to change without notice. Dimensions and specifications shown are within manufacturing tolerances.© Copyright, January 2008, Commercial Products Group of Hart & Cooley, Inc. All Rights Reserved.

11/16” Recess For Terrazzo

Non-Security: Aluminum Floor Doors

• Low Cost Floor AccessMilcor’s F, T and Z Series Non-Security TypeAluminum Floor Doors provide low costaccess where access to equipment orservices located under floors is required.

• Easy AccessibilityEquipped with lift ring access for environ-ments where an unlocked design is accept-able.

Standard Sizes and Model Number(Second dimension is for length on hinge side.)

Dimensions2'0" x 2'0"

2'6" x 2'6"

3'0" x 2'6"

3'0" x 3'0"

Flush CoverModel No. Lbs.F-62 30

F-64 35

F-66 40

F-68 45

Model No. Lbs.T-62 30

T-64 35

T-66 40

T-68 45

Terrazzo CoverModel No. Lbs.Z-62 40

Z-64 45

Z-66 50

Z-68 55

Tile Cover

Flush Door Style (F Series)1/4” Aluminum Plate (Smooth or Safety Tread)

Floor DoorsTechnical Product Information

• Powerful Load Capacity.Designed to support a uniformly distributed load of 200psf on a 40" span to 1,000 psf on a 2'0" span.

• Low MaintenanceMilcor Aluminum Floor Doors provide low maintenance ofall-aluminum welded.

• StylesMilcor Aluminum Floor Doors provide low maintenance ofall-aluminum welded construction.

5/8”

For RecessedApplications, 1/8” Floor Tile(by others)

1/8" Aluminum Plate(Safety Tread or Smooth)

Extruded AluminumFrame

Lift Ring ForEasy Access

GasketDoor Opening Size

1-1/2”

1/8”

21/2"

Door Opening Size

21/2"

1"

Terrazzo

Welded Anchor

Gasket 1/8” Aluminum Flat Plate

Tile Detail (T Series)1/4” Aluminum SmoothPlate (Recessed Cover)

Terrazzo Detail (Z Series)

Door Opening Size is the Same asHole Size.

Additional Keying-In Required forMounting Door Frame

Extruded Aluminum CoverReinforcement

21/2"

SINCE 1902

All information is subject to change without notice. Dimensions and specifications shown are within manufacturing tolerances.© Copyright, January 2008, Commercial Products Group of Hart & Cooley, Inc. All Rights Reserved.

Security: Aluminum Floor Doors

• Powerful Load Capacity.Milcor Security models F or T are designed tosupport a uniformly distributed load of150 psf.

• Two Cover Styles AvailableFlush Cover: Flush with the exposed surfaceof the frame and suitably reinforced to carrythe designed loads.Tile Cover: 1/4 inch recessed smooth coverwith extruded tile stop for installation of floortile in cover.

Standard Sizes and Model Number(Second dimension is for length on hinge side.)

Single-Leaf

Double-Leaf

Dimensions

2'0" x 2'0"2'6" x 2'6"3'0" x 2'6"3'0" x 3'0"

4'0" x 4'0"4'0" x 6'0"5'0" x 5'0"

Flush CoverModel No. Lbs.

F-2424 60F-3030 75F-3630 85F-3636 95

F-4848 160F-4872 220F-6060 230

Tile CoverModel No. Lbs.

T-2424 66T-3030 85T-3630 95T-3636 106

T-4848 180T-4872 246T-6060 258

• Low MaintenanceMilcor Aluminum Floor Doors provide lowmaintenance with all-aluminum weldedconstruction.

• Concrete AnchorsStrap-type concrete anchors fix doors firmlyinto concrete floors.

• Removable HandlesSecurity snap latches with removable tophandles prevent undesired access.

No. of Leafs (Door Opening Size)

Floor DoorsTechnical Product Information

Door Opening Size Per Table(Custom sizes are available.)

Flush CoverGasketRemovable

Handle

Latch SideHinge Side

Snap Latch WithInside & Outside Handles

Plate reinforcing

Vinyl Grip

Door Opening Size

Extruded AluminumFrameTorsion Bar

AnchorsCast Hinge Arm Hold-open

Arm

1/4” Aluminum SafetyTread Plates

3-5/8”

3-5/8”

3-13/16”

2-1/2”

3/4”

Hole Size Required is Larger than Door Opening Size3/16”

SINCE 1902

All information is subject to change without notice. Dimensions and specifications shown are within manufacturing tolerances.© Copyright, January 2008, Commercial Products Group of Hart & Cooley, Inc. All Rights Reserved.

Flush Cover Cover: Security - Steel or Aluminum/ Steel• No Obstruction

Flush cover styles are finished out flush with the concretesurface to present no obstruction or hazard to floor traffic.

• Non-Skid SurfaceThe patterned 3/16” steel or 1/4” aluminum metal surface coverprovides safe, non-skid footing.

• Supports 150 psf LoadStandard reinforced construction handles uniform loads of 150lbs. per sq.ft.

• HardwareMounted to a zinc-plated, riveted, triple-leaf lift hinges, stopchain and a rigid hold-open arm on each leaf.

• Superior Cover MountingCover is mounted to frame with cast steel hinges with torsionsprings, complete with automatic locking hold-open arms andautomatic snap latch. Fixed inside handle for access, withremovable outside handles for security access.

• Material OptionsFloor doors are available in two materials to meet specific designcriteria.

Steel, Prime Painted: FA SeriesAluminum Cover, Steel Frame: FC Series

• Latch OptionsSingle-Leaf Covers equipped with automatic snap latch havingfixed inside and removable outside handles.Double-Leaf Covers are fixed with a throw bolt on the inactive leaf,and a latching mechanism having fixed inside and removableoutside handles on the active leaf.

Concrete Floor2" x 2" x 1/4" Angle

Cast Steel Hinge Arm

Torsion Bar

(Hinge Side)

1-3/4"

3/16" Steel or 1/4”Aluminum Safety Tread

Plate

Hold-Open ArmVinyl Grip

Door Opening Size Per Table(Custom sizes are available.)

Plate Reinforcing

Removable Handle

1"1/8"

1/4" x 1"Anchors

2" x 2" x 1/4" Angle

Snap Latch WithInside & Outside Handles

2"

Standard Sizes and Model Number(Second dimension is for length on hinge side.)

Single-Leaf

Double-Leaf

Dimensions2'0" x 2'0"2'6" x 2'6"3'0" x 2'6"3'0" x 3'0"3’6” x 3’6”3’6” x 3’6”2’10” x3’4”3’4” x 3’10”3’10 x 3’10”4'0" x 4'0"4'0" x 6'0"5'0" x 5'0"

Steel, Prime PaintedModel No. Lbs.FC-1 120FC-2 140FC-3 150FC-4 160FC-5 200 - -FC-6 200FC-7 250FC-8 270FC-9 280FC-10 300FC-11 310

Aluminum Cover/Steel FrameModel No. Lbs.FA-1 140FA-2 160FA-3 175FA-4 195 - -FA-5 275FA-6 240FA-7 300FA-8 340FA-9 350FA-10 440FA-11 450

No. of Leafs (Door Opening Size)

Floor DoorsTechnical Product Information

(Other 3 Sides)

Flush Cover(Terrazzo Cover Available)

For highly corrosive environments, zinc flame-sprayed andpainted option is available.

SINCE 1902

All information is subject to change without notice. Dimensions and specifications shown are within manufacturing tolerances.© Copyright, January 2008, Commercial Products Group of Hart & Cooley, Inc. All Rights Reserved.

Steel and Aluminum• Accessibility and Safety

These doors provide a safe coveredopening for access to equipment orservices located under sidewalks or forpassage of personnel and materials frombasement areas.

• Versatile UsageSidewalk doors are also used as interiordoors in areas where drainage is required.Recessed frames serve as continuousdrainage gutters to divert water to interiordrain outlets.

• Powerful Load Capacity.Milcor GA and GD Models designed tosupport a uniformly distributed load of 300psf. H-20 loading also available for heavierloading capacity requirements.

• Non Corrosive HardwareMounted to a stainless steel hingesequipped with zinc-plated stop chain and arigid hold-open arm on each leaf.

• Latch OptionsSingle-Leaf Covers equipped withautomatic snap latch fixed inside andremovable outside handles.Double-Leaf Covers are fixed with a throwbolt on the inactive leaf, and a latchingmechanism fixed inside with removableoutside handles on the active leaf.

Single-Leaf

Double-Leaf

(Door Opening Size)Dimensions

2'0" x 2'0"2'6" x 2'6"3'0" x 2'6"3'0" x 3'0"3'6" x 3'6"

2'10" x 3'4"3'4" x 3'10"3'10" x 3'10"

4'0" x 4'0"4'0" x 6'0"5'0" x 5'0"

Standard Sizes and Model Number(Second dimension is for length on hinge side.)

Cover Hinge Boltedfrom Inside for EasyMaintenance

Torsion SpringDesign Will NotFreeze Up

Torsion Spring Mounted onFrame. Virtually No Obstruction.

AluminumModel No. Lbs.

GD-1* 75 GD-2* 96 GD-3 102 GD-4 113 GD-5 134

GD-6* 129 GD-7* 150 GD-8* 188 GD-9* 198 GD-10 268 GD-11 278

Prime Painted Stl.Model No. Lbs.GA-1 170GA-2 220GA-3 257GA-4 286GA-5 321

GA-6 278GA-7 348GA-8 440GA-9 482GA-10 642GA-11 706

*Torsion spring not provided on aluminum sidewalk doors in the following standard and special sizes: single leaf type- 2'0" x 2'0" through 4'6",2'6" x 2'6", double leaf type- 2'10" x 3'4" through 5'6", 3'10" x 3'10" through 4'0" x 4'0".

Removable Handle ContinuousFlat Bar AnchorFormed Gutter

Safety Tread SteelPlate Cover

Stainless SteelHinges

Torsion Spring1-1/2” Drainage

Coupling

Longitudinal ReinforcingSnap Latch

Throw Bolt

Sidewalk & Floor DoorsTechnical Product Information

Door Opening Size Per Table(Custom sizes are available.)

No. of Leafs

For highly corrosive environments, zinc flame-sparayed and painted option is available for unit.

3-1/2”

3”

1”

SINCE 1902

All information is subject to change without notice. Dimensions and specifications shown are within manufacturing tolerances.© Copyright, January 2008, Commercial Products Group of Hart & Cooley, Inc. All Rights Reserved.

Floor Door Technical SpecsTechnical Product Information

Guide SpecificationMilcor models F and T security floor doors aredesigned to support a uniformly distributed load of 150psf. Sizes are as indicated on page 22

FrameFlush Cover (F) & Tile Cover (T) Models: Con-structed of extruded aluminum sections with miteredand welded corners. Strap-type concrete anchors arebolted to the frame, and a closed-cell rubber gasket isincluded on the frame to cushion the cover.

CoversFlush Cover (F-style) Models:1/4” aluminum floor plate with a safety tread pattern onthe upper surface, mounted completely flush with theexposed surface of the frame and suitably reinforced tocarry the designed loads.

Tile Cover (T-style) Models:1/4" aluminum recessedfloor plate reinforced to carrythe designed loads. Extruded tile stop provided on thecover and frame to provide a recess to receive (1/8" or3/16") floor tile.

Cover MountingAll Models: Cover mounted to the frame with caststeel hinges equipped with torsion bars, complete withan automatic locking hold-open arm, automatic snaplatch having fixed inside and removable outsidehandles.

Security: AluminumFlush or Tile Cover

Guide SpecificationMilcor models F, T and Z non-security floor doors aredesigned to support a uniformly distributed load from200 psf on a 40" span to 1,000 psf on a 2'0" span.Sizes are as indicated on page 21.

FrameFlush Cover (F) and Tile Cover (T) Models: Con-structed of extruded aluminum sections with miteredand welded corners, with integral masonry anchors,and with a heavy neoprene cushion provided along thetop surface of the cover ledge.

Terrazzo Cover (Z) Models: Constructed of extrudedaluminum sections with mitered and welded corners,with welded masonry anchors, and with a heavyneoprene cushion provided along the top surface of thecover ledge.

CoversFlush Cover (F) Models: 1-1/2" deep extrudedaluminum section with a welded 3/16” aluminum topplate having a safety tread pattern surface.

Tile Cover (T) Models: 1-1/2" deep extruded aluminumsection with a welded 3/16” aluminum top plate havinga flat plate recessed to receive 1/8" floor tile.

Terrazzo Cover (Z) Models: 1-1/2" deep extrudedaluminum section with a riveted 3/16” aluminum topplate, all enclosed by extruded aluminum angles, toprovide a recess to receive 11/16" deep terrazzo.

Cover MountingAll Models: Cover rests free in the frame and isprovided with a chrome lift ring for easy removal fromframe.

Non Security: AluminumFlush or Tile Cover

Technical SpecificationsProduct Information

SINCE 1902

All information is subject to change without notice. Dimensions and specifications shown are within manufacturing tolerances.© Copyright, January 2008, Commercial Products Group of Hart & Cooley, Inc. All Rights Reserved.

Floor Door Technical SpecsTechnical Product Information

Guide SpecificationMilcor models GA or GD doors for sidewalk or floorapplications are equipped with drainage guttersdesigned to support a uniformly distributed load of 300psf. H-20 loading is also available. Sizes and coverleaf types are as indicated on page 24.

FrameConstructed of welded, formed 3/16" steel and/or 1/4”extruded aluminum sections, shaped to serve as acontinuous drainage gutter around the unit andequipped with a 1-3/8" diameter drainage hole with a 1-1/2” outside diameter drain coupling for outlet into aninside drain. Concrete anchors are provided on theframe.

Covers1/4" steel or 1/4" aluminum floor plate with a safetytread pattern on the upper surface mounted flush withthe frame and reinforced to carry the designed loads.

Torsion SpringAssisted by a torsion spring operators attached to theframe unless otherwise recommended by the manufac-turer.

Cover MountingMounted to the frame on stainless steel hinges andequipped with a zinc-plated stop chain and a rigid hold-open arm on each leaf.

LatchSingle Leaf Covers: Cover is equipped with anautomatic snap latch fixed inside and outside handleson the active leaf.Double Leaf Covers: Cover is equipped with a throwbolt on the inactive leaf, a latching mechanism fixedinside and removable outside handles on the activeleaf.

FinishSteel Units: Prime-painted.

Aluminum Units: Standard mill finish.

Note: Where required for highly corrosive environ-ments, units can be zinc-flame sprayed coated andprime-painted at an additional cost and 10 weekdelivery.

Flush Cover Sidewalk DoorsSteel or Aluminum

Guide SpecificationMilcor steel framed security floor door models FA andFC are designed to support a uniformly distributed loadof 150 psf. Sizes are as indicated on page 23.

FrameModels (FA & FC): Constructed of welded 1/4” steelangles with welded concrete anchors and primepainted.

CoversModels (FA & FC): 3/16” steel (FA) or 1/4” aluminum(FC) floor plate with a safety tread pattern on the uppersurface and suitably reinforced.

Cover MountingModels (FA & FC): Mounted to the frame with heavy-duty triple-leaf steel hinges equipped with torsion barsand complete with an automatic locking hold-open arm,automatic snap latch having fixed inside and removableoutside handles.

FinishSteel Units: Prime-painted.

Aluminum/ Steel Units: Standard mill finish cover andprime-painted steel frame.

Note: Where required for highly corrosive environ-ments, units can be zinc-flame sprayed coated andprime-painted at an additional cost and 10 weekdelivery.

Flush Cover Floor Door: Security StyleSteel or Aluminum/ Steel