Role of ICT in Power Sector

28
Role of ICT in Power Sector Presented by Shri. Kishor Chavan & Rakesh Guhagarkar Deputy Director(Technical), Maharashtra Electricity Regulatory Commission, Mumbai D2-01-28

description

D2-01-28. Role of ICT in Power Sector. Presented by Shri . Kishor Chavan & Rakesh Guhagarkar Deputy Director(Technical), Maharashtra Electricity Regulatory Commission, Mumbai. Agenda. Role of ICT in Power Sector Challenges in Transmission WAMS / PMU Real Time Application of WAMS - PowerPoint PPT Presentation

Transcript of Role of ICT in Power Sector

Page 1: Role of ICT in Power Sector

Role of ICT in Power Sector

Presented by Shri. Kishor Chavan & Rakesh Guhagarkar

Deputy Director(Technical),Maharashtra Electricity Regulatory Commission, Mumbai

D2-01-28

Page 2: Role of ICT in Power Sector

Agenda

• Role of ICT in Power Sector

• Challenges in Transmission

• WAMS / PMU

• Real Time Application of WAMS

• WAMS implementation in Maharashtra, India.

• Regulatory Support

Page 3: Role of ICT in Power Sector

From Traditional to Future Grid

• Centralized power generation• One-directional power flow• Generation follows load• Operation based on historical experience• Limited grid accessibility for new producers

Traditional Grid• Decentralized and distributed power generation• Intermittent renewable power generation• Consumers become also producers (CPP)• Multi-directional power flow (Inter Regional) Short Term Open Access Transactions are increasing• Operation based more on real-time data

Future Grid

Page 4: Role of ICT in Power Sector

Information and Communication Technologies has a major role to play:-

By allowing two way communication throughout the grid,

Not only power but information is also transported,

Numerous intelligent devices are continuously interacting with each other

Role of ICT in Power Sector

Page 5: Role of ICT in Power Sector

Role of ICT in Power Sector

Major Applications of ICT in Power Sector:-

Automatic Meter Reading

Remote Disconnect and Reconnect

Demand Side Management and Load Management

Integration of Renewable Energy

Integration of Distributed Generation, standby, mini grids and off-grid

generation

Demand response

Advanced Metering Infrastructure (AMI)

Wide Area Measurement System (WAMS)

Phase Measurement Unit (PMU)

Page 6: Role of ICT in Power Sector

Increasing demand for power

Transmission networks get bigger by aggregation (island

interconnected)

Distance between generation and load changes

Laws, regulations & politics often impede building power plants

where they are needed

Introduction of distributed energy resources e.g. wind, Solar

Load flow becomes volatile

Modern supervision and smarter tools to manage the increasing

complexity of the grid are needed;

Increase the utilization of new technologies e.g. WAMS

to allow the networks to operate closer to its capacity

while maintaining system security

General Challenges in Transmission Networks

Page 7: Role of ICT in Power Sector

Wide Area Management System

Conventional system:-Analog and digital information related to the power system, such as circuit breaker status, frequency, voltage and power flow (MW/MVAr) measured at substation level and is presented in the LDC through SCADA/EMS .The information is routed and updated every 10 seconds at respective LDCs.

Limitations of SCADA:- Angular separation between coherent group of generators within a synchronous grid is representative of the grid stress. The measurement of angular separation and its telemetry at the control centre level in SCADA / EMS has limitations.

The load angle is either estimated from the available SCADA data or the angular separation between pair of substations is derived offline with the help of power flow on the line, impedance of the line and respective voltage.

Both these methods have limitations due to data latency and inaccuracies inherent in SCADA/EMS.

Page 8: Role of ICT in Power Sector

Wide Area Management System

WAMS is an ICT application which has overcome the limitations of SCADA.

With WAMS, it is possible

To monitor the phase angles at the control centre.

To visualize magnitude and angle of each phase of the three phase voltage/current , frequency, rate of change of frequency and angular frequency at every few milliseconds interval (say 40 ms) in the LDCs.

To observe transient / dynamic behavior of the system in near real time at the control centers.

PMU

PMU

PMUPMU

PMUPMU

PMU

PMU

PMU

Page 9: Role of ICT in Power Sector

Wide Area Monitoring (WAMS) : Phasor vs. SCADA Comparison

Page 10: Role of ICT in Power Sector

Wide Area Measurement System

Page 11: Role of ICT in Power Sector

Phase Measurement Unit

The Phasor Measurement Unit (PMU) is the basic building block of WAMS.

PMU definition (as stated in IEEE Std.C37.118-2011):“A device that produces synchronized measurements of phasor (i.e. its amplitude and phase), frequency, ROCOF (Rate of Change Of Frequency) from voltage and/or current signals based on a common time source that typically is the one provided by the Global Positioning System UTC-GPS.”

PMU measures the system state viz. voltage and angle of a particular location at a rate of multiple samples per second. This data is time stamped through a common reference and transmitted to the Phase Data Concentrator (PDC) installed at a nodal point, through high speed communication medium.

Page 12: Role of ICT in Power Sector

Phase Measurement Unit

Phasor represents magnitude and phase angle at any given instant of sine wave of voltage or current

PMU typical configuration

Page 13: Role of ICT in Power Sector

Wide Area Monitoring (WAMS) : Real time Application

Phase Angle Monitoring Voltage Stability Monitoring Power Oscillation Monitoring

Page 14: Role of ICT in Power Sector

WAMS Application : Phase Angle Monitoring

Benefits: Provide operator with real time information about voltage phase angle deviation, Improve voltage control, improve system stability, security and reliability , and operate safety carrying components closer to their limit.

Page 15: Role of ICT in Power Sector

WAMS Application : Voltage Stability Monitoring

Early warning

Emergency alarm

Normal Operation

Benefit: Early warning against voltage collapses, Immediate stop of cascading effects, and Protection against uprising voltage instabilities.

Page 16: Role of ICT in Power Sector

WAMS Application : Power Oscillation Monitoring

WAMS Benefit: Detection of oscillation, Assessment of power system damping, Increase power transfer at defined security, and Early warning to avoid power system collapse.

System Status: Normal, Warning and Alarm

Page 17: Role of ICT in Power Sector

Benefit of Using PMU Real time monitoring Post-disturbance analysis Adaptive protection to avoid cascading outage Power system restoration

Source: Dr. Luigi Vanfretti, KTH Sweden

Improve calculation for real time path flow and optimal dispatch Provide actual limits of the system instead of the conservative ones from offline calculationsImproved backup protection Reduce chance of recurrence of system outage

Page 18: Role of ICT in Power Sector

Special Report Question

Q.1 How is ICT utilized in Maharashtra, India, for implementing WAMS? What is the percentage of grid observable using such systems? Any challenges in implementation?

Page 19: Role of ICT in Power Sector

EXISTING grid Management using SCADA/EMS

Page 20: Role of ICT in Power Sector

Limitation of Existing SCADA/EMS

Page 21: Role of ICT in Power Sector

PMU Implementation in India

• In India, fourteen (14) Phasor Measurement Units (PMUs) have been commissioned as on 31st May 2012. In the Northern Region, the PMUs have been placed at nine 400 kV substations viz. Vindhyachal (HVDC back-to-back station), Kanpur (with SVC), Dadri (HVDC inverter terminal), Moga, Kishenpur, Agra, Bassi, Hisar and Karcham Wangtoo.

• In Western Region PMUs have been placed at two 400 kV substations viz. Raipur and Bhadravati. In Southern Region, they have been placed at three 400 kV substations viz. Salem, Hyderabad and Bengaluru.

• The three Phasor Data Concentrators (PDC) have been installed at the respective Regional Load Despatch Centres (RLDCs) located in New Delhi, Mumbai and Bengaluru. Placement of PMUs/PDCs at few more locations in India has been envisaged under the pilot projects taken up by the RLDCs.

• After completion of all the pilot projects, there would be 53 PMUs and 6 PDCs in India.

Page 22: Role of ICT in Power Sector

Architecture after completion of the pilot projects in all the Regions

Page 23: Role of ICT in Power Sector

WAMS implementation in Maharashtra by MSETCL

23

WIDE AREA MEASUREMENT SYSTEMS (WAMS)- To enhance Operation, Monitoring capability and observability of GRID

WAMS SCOPE

1. PMU Locations: 15 (400kV stations and some

220kV stations)

2. GPS Locations :15

3. At SLDC-Kalwa -

Phasor Data Concentrator(PDC),

Visualisation software,

Archiving software and Historian server

Situational Awareness

Commissioned on Aug- 2012, installation of

Situational Awareness is in progress.

Situational Awareness

PMUs : 15 Locations

PDC at SLDC Kalwa

Page 24: Role of ICT in Power Sector

Challenges in Implementation of WAMS

1. Scale of Project: implement a full fledged project or first we should go for a pilot project and then scale it up to a full project.

2. Selection of PMU Locations: Reasonably far off nodes to get a wider footprint.close to large generating complex Availability of fast communication from the PMU location.

3. Reliability of synchrophasor data: Data loss occurs due to communication problem between PMU and control center.4. data retrieval from the historian:Retrieval of data from historian is possible only for duration of 3 minutes. Hence retrieval of longer duration data is quite time consuming.5. Analysis of synchrophasor dataMicrosoft excel is being used for plotting and analyzing of synchrophasor data. There is limitation with excel that only 35000 data points can be plotted. Hence better plotting techniques needs to be explored for plotting of data for larger duration.

Page 25: Role of ICT in Power Sector

Q.2 Please give your future plans on how would envision the grid operations with WAMS and necessary regulatory support requirements.

Ans. Future Plan: Phase-1: Placement of 1186 nos. PMUs at all lines in HVDC terminal stations, 400kV & above voltage level S/s, generating station stepped up at 220kV level & above where Fibre Optic(FO) cable along with communication equipment is either existing or being implemented by 2014-15.

Placement of Nodal PDC (27 nos) at strategic sub-station, Master PDC(25nos) at SLDCs, Super PDC (5) at RLDCs, 2 No PDC at Main & BackupNLDC, Remote console at each RPC(5) , UT(3) ,Sikkim , NTMC(2),CEA(1) & NER States(4) ,Total 16 .

Phase-2: Placement of balance 483 nos. PMUs at all HVDC terminal stations, 400kV & above voltage level S/s, generating station stepped up at 220kV level & above along with provision of Fibre Optic connectivity and communication equipments.

Page 26: Role of ICT in Power Sector

FIBRE OPTIC COMMUNICATION NETWORK WITH PMU LOCATION IN WESTERN REGION –Phase-I ( 83 PMU)

Page 27: Role of ICT in Power Sector

Regulatory Support Requirement To provide certainty and confidence to utilities, investors and technology providers for making necessary investment

Regulatory support is required across 3 key dimensions:

Economic Regulation

Optimal tariff design for promoting ICT applicationsInvestment approval mechanism for utilities

Safety and Standards

Standard for Cyber securityInter-operability standards

Awareness & Capacity Building

Consumer awareness Capacity building for utilities, regulators and technology providers

Page 28: Role of ICT in Power Sector

Tamasoma jyotir gamaya(From darkness unto light)

Thank You