Robustness of Steel Joints in Fire Robustness is the ability of a structure to withstand events...

1
Robustness of Steel Joints in Fire Robustness is the ability of a structure to withstand events like fire, explosions, impact or the consequences of human error, without being damaged to an extent disproportionate to the original cause. Two main approaches are recommended for structural robustness: Tying force approach: tying a steel frame horizontally and vertically to increase its structural continuity and create a structure with a high level of robustness. Alternate load path method: if part of a structure had been removed by an accidental action, the remaining members were still well connected to develop an alternative load path which transfers the load of the collapsed members to the surrounding stiffer members. The research work described in this poster is part of a project funded under Grant EP/C510984/1 by the Engineering and Physical Sciences Research Council of the United Kingdom. This support is gratefully acknowledged by the authors. In this project, the authors would also like to thank technical staff for their assistance and excellent work. Background Ying Hu & Dr. Buick Davison and Prof. Ian Burgess (Supervisors), Department of Civil and Structural Engineering Prof. Roger Plank (Supervisor), School of Architecture The University of Sheffield Robustness of Simple Steel Connections in Fire Simulation of Endplate Connections in Fire Standard 8.8 Bolts in Fire Modes of failure for standard 8.8 bolts in fire From test results, the premature failure may be prevented by using standard 8.8 bolts with grade 10 nuts, and closer tolerance in threads may help bolt assemblies to achieve better performance in fire conditions. It is not suggested to use zinc plated nuts, which may impair the performance of bolts in fire The avoidance of thread stripping between bolt and nut threads is beneficial for robustness of steel connections in fire conditions. Conclusions and Recommendations What is the robustness in steel structures? i. Web cleats ii.Fin plates iii.Flexible end plates Simple steel connections include fin plates, flexible end plates and web cleats. Assumptions for simple steel connections: a) to be ductile, possess large rotation capacity and nominally pin the beams and columns. b) to resist shear forces only a) variation of tying resistance of simple connections in a fire situation. b) alteration of ductility in fire, (recent research, completed at The University of Sheffield proved that the ductility needed to be taken into account in a fire situation, as an indicator of structural robustness) c) modes of failure for simple steel connections in a fire situation (failures caused by brittle components or ductile failures) Why is research needed for structural 8.8 bolts? I. Background Standards for grade 8.8 bolts a) Bolt shank failure b) Threads stripping a) Withdrawn standards BS 3692:1967 and BS 4190:1967 b) Current bolt standards British standards BS 3692:2001 and BS 4190:2001 European standards BS EN ISO 4014 and BS EN ISO 4032 BS EN ISO 4017 and BS EN ISO 4032 A comparative study was performed for bolts ordered to British standards (BS 4190: 2001) and European standards (BS EN ISO 4014) at the University of Sheffield. The first objective was to identify an approach to eliminate premature failure due to thread stripping. The second was to observe the performance of these two classes of bolts in fire conditions II. Experimental arrangement and objectives III. Experimental results a) reduction factors for 8.8 bolts in fire b) bolts’ performance in fire furna ce Flexible End Plates in Fire Catenary action is the behaviour of a steel beam acting as a cable hanging from the surrounding cold structure, which is observed in a fire situation. Note that, to develop catenary action in fire, steel connections are required to experience a large rotation and support a tensile load (tying force). At ambient temperatures, the minimum tying force is taken to be 75 kN. In the tying force approach, the tying force is the action which is generated within steel beams and passed on to steel connections. Note that the tying forces applied in a structure could be horizontal and vertical, even inclined in catenary action. However, the tying resistance is defined as the ability of steel connections to resist a horizontal force in accordance with an industry standard design manual. This definition implicitly suggests that engineers should determine the tying resistance of simple steel connections in the absence of beam rotations (without considering the moment). To develop catenary action in fire, steel connections are required to be ductile enough to accommodate the induced rotation in a fire situation. Therefore, ductility (rotational capacity) may be regarded as an indicator of robustness of steel connections in fire conditions. I. Catenary action and tying force approach II. Experimental arrangement for flexible end plates in fire In structural fire engineering, it is implicitly assumed that simple steel connections are capable of maintaining structural integrity to resist progressive collapse. But evidence from full scale fire tests (at the BRE Large Building Test Facility at Cardington) demonstrates that steel connections may be the weakest and most vulnerable components in fire conditions. Relying solely on standard design details, the failure of steel connections may arise from rupture of endplates, fracture of bolts or bearing in the beam web. To investigate the robustness of joints in fire conditions, a research group at the University of Sheffield developed a series of tests for simple steel connections. From test results, it was clearly proved that simple connections, except web cleats, do not possess sufficient rotation capacity to permit the deformation required to catenary action in fire conditions. Damage in brittle components (bolts and welds) may provoke the failure of connections; therefore, part of the research effort in this project has been put into the investigation of the performance of brittle components in fire conditions. a) Bearing failure and bolt fracture for fin plates b) Rupture of endplates for partial depth endplates A series of experimental tests were carried out at the University of Sheffield for investigation of robustness of steel connections in fire conditions. Steel sections (254UC89 and 305x165UB40) were supplied by Corus and fabricated by Billington Structures Ltd. All the bolts were M20 Grade 8.8, used in 22 mm clearance holes, and standardized fitting end plates were used for simple connections. All these tests were performed in an electric furnace and the load was applied through three linked Φ26.5 mm Macalloy bars. a) Catenary action b) Furnace for tests III. Experimental results for flexible end plates c) Sketch of loading system d) Location of a flexible endplate connection e) Test results for flexible endplate connections and modes of failure in fire f) Test results for flexible endplate connections Issues concerning robustness of simple steel joints in fire conditions It is clearly observed, from the load-versus-rotation curves, that the resistance and rotation capacity of steel connections are both decreased at high temperatures. The reduced rotation capacity of flexible end plates at high temperatures is caused by the rupture of end plates occurring before the beam flange contacts with the column flange, which occurs at ambient temperatures as evidenced by the kink in the curve at about 6 o rotation. From experimental results, only one mode of failure has been observed for flexible end plates in fire conditions: the rupture of endplates around heat affected zone. For a real structure in fire, simple steel connections are capable of resisting some moment and the inclined tying force may be produced within a steel beam. As a consequence, the tying resistance calculated in accordance with the industry standard Green book and EC3 are likely to overestimate the real resistance of these connections. Comparison between experimental results and calculated values proved this point clearly, as shown in the left table. The data in this table demonstrates that the minimum tying force (75 kN) for simple steel connections cannot be assured at high temperatures (over 450 o C). The ductility of flexible end plates is a crucial issue concerning robustness of steel structures in fire. Conducting experimental tests is always time consuming and expensive. Furthermore, carrying out tests at high temperatures has extra difficulties in recording displacements and strains. Thus, using experimental data for validation, but simulating the connection performance with finite element modelling, provides an opportunity for wider parametric investigations and eliminates the limitations associated with experiments. I. Why do engineers need finite element modelling? III. Verifying numerical model with experimental results The above FE model started with creation of individual components such as bolts, endplates, beams and columns. These components were then assembled into a numerical model in the global coordinate. A small number of cohesive elements has been embedded into this model, as indicators of the failure of endplates. The contact interactions between bolts, endplates and column flanges were simulated by surface-to-surface formulations in ABAQUS. II. How to create a finite element model for endplate connections? For realistic simulations, actual material properties must be required in the solution procedure. The material properties for the various components of steel connections may be determined from the engineering stress-strain relationships recommended in Eurocode 3. In comparison with experimental results, the numerical model, embedded with cohesive elements, is capable of estimating the resistance and ductility of flexible endplate connections in fire conditions. Furthermore, through this comparison, the quasi-static analysis technique is proved to be a reliable and suitable tool to effectively simulate the performance of bolted connections. Therefore, the simulation strategies employed in this part may be reliable for the further parametric studies of flexible endplate connections. a) The premature failure of bolts, owing to thread stripping, has been reported in the connection tests (not in flexible endplate tests), and the avoidance of this failure mode is beneficial for robustness of steel connections in fire conditions. b) Zinc plated (zinc finished) nuts are not suggested to be used in steel construction, and selecting black finished nuts (Grade 10) assembled with 8.8 bolts is an effective measure in achieving improved performance of bolts at both ambient and elevated temperatures. c) The connection tests demonstrate that both the resistance and rotation capacity of flexible end plate connections were reduced at high temperatures, and the mode of failure d) From experimental results, the minimum tying resistance (75 kN) cannot be assured for partial depth endplate connections at high temperatures. The tying capacities calculated in accordance with the industry standard Green book are likely to overestimate the real resistance of simple steel connections in fire conditions. e) The finite element model, embedded with cohesive elements, was presented and verified with experimental results. The quasi-static analysis strategy was proved to be a reliable and suitable tool to effectively simulate the performance of bolted connections in fire. Further Research a) Currently, the research in connection already completed experimental tests and validation of numerical models. To improve understanding, a series of parametric studies will be conducted on a range of steel connections by using the finite element simulation. b) To present a simplified model is the eventual target in this research work. This (mechanical) model is based on fully understanding of the performance of individual components in fire conditions, and simplifies these components with bi-linear or tri-linear load-deformation characteristics. As a consequence, the mechanical model should represent the performance of steel connections, which is now the most simple and popular approach to simulate the performance of simple connections in fire. Acknowledgemen t

Transcript of Robustness of Steel Joints in Fire Robustness is the ability of a structure to withstand events...

Page 1: Robustness of Steel Joints in Fire  Robustness is the ability of a structure to withstand events like fire, explosions, impact or the consequences of.

Robustness of Steel Joints in Fire

Robustness is the ability of a structure to withstand events like fire, explosions, impact or the consequences of human error, without being damaged to an extent disproportionate to the original cause.

Two main approaches are recommended for structural robustness:

Tying force approach: tying a steel frame horizontally and vertically to increase its structural continuity and create a structure with a high level of robustness.

Alternate load path method: if part of a structure had been removed by an accidental action, the remaining members were still well connected to develop an alternative load path which transfers the load of the collapsed members to the surrounding stiffer members.

The research work described in this poster is part of a project funded under Grant EP/C510984/1 by the Engineering and Physical Sciences Research Council of the United Kingdom. This support is gratefully acknowledged by the authors. In this project, the authors would also like to thank technical staff for their assistance and excellent work.

Background

Ying Hu & Dr. Buick Davison and Prof. Ian Burgess (Supervisors), Department of Civil and Structural Engineering Prof. Roger Plank (Supervisor), School of Architecture

The University of Sheffield

Robustness of Simple Steel Connections in Fire

Simulation of Endplate Connections in Fire

Standard 8.8 Bolts in Fire

Modes of failure for standard 8.8 bolts in fire

From test results, the premature failure may be prevented by using standard 8.8 bolts with grade 10 nuts, and closer tolerance in threads may help bolt assemblies to achieve better performance in fire conditions.

It is not suggested to use zinc plated nuts, which may impair the performance of bolts in fire

The avoidance of thread stripping between bolt and nut threads is beneficial for robustness of steel connections in fire conditions.

Conclusions and Recommendations

What is the robustness in steel structures?

i. Web cleats ii. Fin plates iii. Flexible end plates

Simple steel connections include fin plates, flexible end plates and web cleats.

Assumptions for simple steel connections:

a) to be ductile, possess large rotation capacity and nominally pin the beams and columns.

b) to resist shear forces only

a) variation of tying resistance of simple connections in a fire situation.

b) alteration of ductility in fire, (recent research, completed at The University of Sheffield proved that the ductility needed to be taken into account in a fire situation, as an indicator of structural robustness)

c) modes of failure for simple steel connections in a fire situation (failures caused by brittle components or ductile failures)

Why is research needed for structural 8.8 bolts?

I. Background

Standards for grade 8.8 bolts

a) Bolt shank failure b) Threads stripping

a) Withdrawn standards

BS 3692:1967 and BS 4190:1967

b) Current bolt standards

British standards

BS 3692:2001 and BS 4190:2001

European standards

BS EN ISO 4014 and BS EN ISO 4032

BS EN ISO 4017 and BS EN ISO 4032

A comparative study was performed for bolts ordered to British standards (BS 4190: 2001) and European standards (BS EN ISO 4014) at the University of Sheffield.

The first objective was to identify an approach to eliminate premature failure due to thread stripping.

The second was to observe the performance of these two classes of bolts in fire conditions

II. Experimental arrangement and objectives

III. Experimental results

a) reduction factors for 8.8 bolts in fire

b) bolts’ performance in fire

furnace

Flexible End Plates in Fire

Catenary action is the behaviour of a steel beam acting as a cable hanging from the surrounding cold structure, which is observed in a fire situation. Note that, to develop catenary action in fire, steel connections are required to experience a large rotation and support a tensile load (tying force). At ambient temperatures, the minimum tying force is taken to be 75 kN.

In the tying force approach, the tying force is the action which is generated within steel beams and passed on to steel connections. Note that the tying forces applied in a structure could be horizontal and vertical, even inclined in catenary action.

However, the tying resistance is defined as the ability of steel connections to resist a horizontal force in accordance with an industry standard design manual. This definition implicitly suggests that engineers should determine the tying resistance of simple steel connections in the absence of beam rotations (without considering the moment).

To develop catenary action in fire, steel connections are required to be ductile enough to accommodate the induced rotation in a fire situation. Therefore, ductility (rotational capacity) may be regarded as an indicator of robustness of steel connections in fire conditions.

I. Catenary action and tying force approach

II. Experimental arrangement for flexible end plates in fire

In structural fire engineering, it is implicitly assumed that simple steel connections are capable of maintaining structural integrity to resist progressive collapse. But evidence from full scale fire tests (at the BRE Large Building Test Facility at Cardington) demonstrates that steel connections may be the weakest and most vulnerable components in fire conditions. Relying solely on standard design details, the failure of steel connections may arise from rupture of endplates, fracture of bolts or bearing in the beam web.

To investigate the robustness of joints in fire conditions, a research group at the University of Sheffield developed a series of tests for simple steel connections. From test results, it was clearly proved that simple connections, except web cleats, do not possess sufficient rotation capacity to permit the deformation required to catenary action in fire conditions. Damage in brittle components (bolts and welds) may provoke the failure of connections; therefore, part of the research effort in this project has been put into the investigation of the performance of brittle components in fire conditions. a) Bearing failure and bolt fracture for fin plates

b) Rupture of endplates for partial depth endplates

A series of experimental tests were carried out at the University of Sheffield for investigation of robustness of steel connections in fire conditions.

Steel sections (254UC89 and 305x165UB40) were supplied by Corus and fabricated by Billington Structures Ltd. All the bolts were M20 Grade 8.8, used in 22 mm clearance holes, and standardized fitting end plates were used for simple connections. All these tests were performed in an electric furnace and the load was applied through three linked Φ26.5 mm Macalloy bars.

a) Catenary action

b) Furnace for tests

III. Experimental results for flexible end plates

c) Sketch of loading system

d) Location of a flexible endplate connection

e) Test results for flexible endplate connections and modes of failure in fire

f) Test results for flexible endplate connections

Issues concerning robustness of simple steel joints in fire conditions

It is clearly observed, from the load-versus-rotation curves, that the resistance and rotation capacity of steel connections are both decreased at high temperatures. The reduced rotation capacity of flexible end plates at high temperatures is caused by the rupture of end plates occurring before the beam flange contacts with the column flange, which occurs at ambient temperatures as evidenced by the kink in the curve at about 6o rotation.

From experimental results, only one mode of failure has been observed for flexible end plates in fire conditions: the rupture of endplates around heat affected zone.

For a real structure in fire, simple steel connections are capable of resisting some moment and the inclined tying force may be produced within a steel beam. As a consequence, the tying resistance calculated in accordance with the industry standard Green book and EC3 are likely to overestimate the real resistance of these connections. Comparison between experimental results and calculated values proved this point clearly, as shown in the left table.

The data in this table demonstrates that the minimum tying force (75 kN) for simple steel connections cannot be assured at high temperatures (over 450oC).

The ductility of flexible end plates is a crucial issue concerning robustness of steel structures in fire.

Conducting experimental tests is always time consuming and expensive.

Furthermore, carrying out tests at high temperatures has extra difficulties in recording displacements and strains.

Thus, using experimental data for validation, but simulating the connection performance with finite element modelling, provides an opportunity for wider parametric investigations and eliminates the limitations associated with experiments.

I. Why do engineers need finite element modelling?

III. Verifying numerical model with experimental results

The above FE model started with creation of individual components such as bolts, endplates, beams and columns. These components were then assembled into a numerical model in the global coordinate.

A small number of cohesive elements has been embedded into this model, as indicators of the failure of endplates. The contact interactions between bolts, endplates and column flanges were simulated by surface-to-surface formulations in ABAQUS.

II. How to create a finite element model for endplate connections?

For realistic simulations, actual material properties must be required in the solution procedure. The material properties for the various components of steel connections may be determined from the engineering stress-strain relationships recommended in Eurocode 3.

In comparison with experimental results, the numerical model, embedded with cohesive elements, is capable of estimating the resistance and ductility of flexible endplate connections in fire conditions.

Furthermore, through this comparison, the quasi-static analysis technique is proved to be a reliable and suitable tool to effectively simulate the performance of bolted connections.

Therefore, the simulation strategies employed in this part may be reliable for the further parametric studies of flexible endplate connections.

a) The premature failure of bolts, owing to thread stripping, has been reported in the connection tests (not in flexible endplate tests), and the avoidance of this failure mode is beneficial for robustness of steel connections in fire conditions.

b) Zinc plated (zinc finished) nuts are not suggested to be used in steel construction, and selecting black finished nuts (Grade 10) assembled with 8.8 bolts is an effective measure in achieving improved performance of bolts at both ambient and elevated temperatures.

c) The connection tests demonstrate that both the resistance and rotation capacity of flexible end plate connections were reduced at high temperatures, and the mode of failure observed for these connections is the rupture of endplate around heat affected zone.

d) From experimental results, the minimum tying resistance (75 kN) cannot be assured for partial depth endplate connections at high temperatures. The tying capacities calculated in accordance with the industry standard Green book are likely to overestimate the real resistance of simple steel connections in fire conditions.

e) The finite element model, embedded with cohesive elements, was presented and verified with experimental results. The quasi-static analysis strategy was proved to be a reliable and suitable tool to effectively simulate the performance of bolted connections in fire.

Further Researcha) Currently, the research in connection already completed experimental tests and validation

of numerical models. To improve understanding, a series of parametric studies will be conducted on a range of steel connections by using the finite element simulation.

b) To present a simplified model is the eventual target in this research work. This (mechanical) model is based on fully understanding of the performance of individual components in fire conditions, and simplifies these components with bi-linear or tri-linear load-deformation characteristics. As a consequence, the mechanical model should represent the performance of steel connections, which is now the most simple and popular approach to simulate the performance of simple connections in fire.

Acknowledgement