Right time, Right amount, Right lubricant · Lubrication System Oil/ SLR System LHL System Number...
Transcript of Right time, Right amount, Right lubricant · Lubrication System Oil/ SLR System LHL System Number...
-
Positive Displacement Injector (PDI) System for Small-Medium Machines
Series Progressive System for Small-Large Machines
General CatalogCentralized Lubrication Systems
Grease SystemRight time, Right amount, Right lubricant
-
LUBE Hybrid Lubricant LHL
Comparison of Lubricant Consumption and Associated Costs
for Machine Tools
Operating Life of Cutting Fluid
Standard System Layout
31
32
33
Maintenance-free Lubrication SystemsLUBE Hybrid Centralized Lubrication Systems LHL
-
31 32
Maintenance-free Lubrication
Systems LUBE Hybrid Centralized
Lubrication Systems LHL
Comparison of Lubricant of Consumption and Associated Costs of for Machine Tools
Comparison of Lubricant of Consumption and Associated Costs
Lubrication System Oil/ SLR System LHL System
Number of lubrication points 23
Lubricant Oil#68 LHL X-100
Cutting Fluid Water-soluble
Total lubricant volume/time 2.5mℓ 1.45mℓ
Comparison with oilSmall Machining Center manufacturing hydraulic system parts●TOOL SIZE #30●Number of lubrication points (X,Y,Z) 23 points in total
Quantity of LHL consumed: Based on our standard LHL quantity & interval Table. 60m/min. Traveling speed gives 5 hours interval.・ The comparison above is just for reference. Actual oil and LHL quantities required for each lubrication cycle, the annual
consumptions and costs vary depending on the actual machine operating conditions, lubrication conditions, essential parts size and other factors.
Oil LHL
Annual lubricant consumption 87.6ℓ 2.1ℓ
Annual lubricant refilling time 96Times 2Times
Annual CO2 Emissions 649kg 11.9kg
Comparison of cost between oil and LHL $2,300.00 $638.50
Advantages of OilLiquidity, Excellent Transport Property, No Solidification
Advantages of GreaseHigh Load-carrying Capacity, Wear Resistance, Water Resistance, Excellent Oil Film Maintenance Property, Adherent Property
LUBE Hybrid Lubricants - LHLDeveloped Based on Our 45-year History of Failures and Successes
・Oil washed away by cutting fluid (Causing rust).・ Oil mixed into cutting fluid causing deterioration and/or decomposition of cutting fluid.・Frequent oil refilling and large consumption of oil boosting up the operational costs.
・Grease solidification.・ Used grease accumulated in guides or other parts that requires clean-up.・Reintroduction of metal chips caught by piled up grease into machines.
Problems with oil lubrication Problems with grease lubrication
Integrating the Advantages of Oil and Grease
Equipped with a centralized oil lubrication system(Lubricant: Daphne Multiway 68MT)
Cutting fluid of company N’s machining unit
Operating Life of Cutting Fluid
The deterioration and/or shortened operating life of cutting fluid is partly caused by lubrication oil and/or hydraulic oil mixed in the cutting fluid.
The LHL systems minimize the amount of lubricant mixed in the cutting fluid, reducing to less than one-tenth of that of oil.
Relationship between the deterioration of cutting fluid and tramp oil in the cutting fluid
Microorganisms
Metal chips
Diluting agent (water)
Nutrient source: Oil, Phosphorus
Dissolved Mg, Ca, and Fe ions
Hydraulic oil and/or insoluble cutting oil mixed in cutting fluid.
Decomposition of components
Drop in pH
Cutting fluid
becom
ing unstable
Discom
posed
comp
onents caught b
y or adsorb
ed to M
etal chips.
Drop
in concentration
Source: Materials provided by Kyodo Yushi Co., Ltd.
Lubricant
Increase in hardness
Emulsification
Increase in hardness
Evaporation of water
Accumulation of metabolites
Deterioration
Change in appearance
Foul smell
Deteriorated corrosion resistance
Degraded cutting performance
*The results may be different from what shown in the photo below depending on conditions.
Lubricant
Machine User A: Investigation of tramp oil in cutting fluidDetails of investigation: Investigating the conditions of the cutting fluid sampled out of the machining centers located in the same machining line.
Water-soluble cutting fluid
< Cutting fluid sampled from a machine lubricated with LHL>
Installed LHL system in December 2006.Cutting fluid of company S’s machining unit
Being in the same machining line, maintenance works for the cutting fluid of these two machines were done at the same time. The cutting fluid samples were collected randomly while the coolant pumps were running followed by being left to rest for three days. Tramp oil was observed in the sample from the machine with oil lubrication system while it was hardly observed in the sample from the machine with LHL lubrication system.
The amount of lubricant delivered by LHL system is 5% to 10% of that of the oil system. However, when it comes to the amount of lubricant actually mixed in the cutting fluid, considering LHL’s water resistance and adhesive property, the amount of LHL mixed in the cutting fluid would be even smaller.
-
33
Positive Displacement Electric Pump S Series EGM Ⅱ EGME Ⅱ
Standard System Layout
⑧⑨ ⑩
③
②
④⑤⑥⑦
④⑤⑥⑦
⑯
⑲⑳
③⑲
⑲
⑳
②
②
⑧⑨ ⑳⑯
⑱
⑱
①
⑰
⑪⑯
⑯⑲⑳
⑱
⑮⑯
⑮⑯⑮⑯⑮⑯
⑥⑨
①
②
③
⑤
⑥
⑥
⑦⑨ ⑩
⑫
⑫
⑫
⑫
⑬
⑬⑬
⑭
⑭
⑰
⑱
⑲
⑱
⑳⑪ ④
“Positive Displacement Injector System”
“Series Progressive System”
35
37
39
【Pump】
S Series
EGM Ⅱ
Positive Displacement Injector (PDI) System for Small-Medium Machines
No. Part Description Quantity1 Motor-driven grease pump 12 Pressure gauge 13 Pressure switch 14 Metering valve 155 Junction 36 Junction 37 Elbow adapter 38 Straight adapter 129 Straight connector 210 Compression bushing 3011 Compression sleeve 3012 High-pressure straight fitting 613 High-pressure elbow fitting 414 High-pressure flexible hose 8m15 Hose sleeve 616 Hose stud 617 Steel tubing 4mm 8m18 Steel tubing 6mm 2m19 Plug 320 Pipe clip 621 Grease cartridge 1
No. Part Description Quantity1 EGM-MP 12 Progressive valve 33 Proximity sensor 34 Check assembly 155 Clamping ring 156 Sleeve 157 Cap nut 158 Washer 39 Plug 310 Junction 111 Junction 312 Elbow adapter 313 Elbow adapter 1214 Compression bushing 1515 Compression sleeve 1516 High-pressure fitting 1017 High-pressure fitting 418 Flexible hose 1019 Hose sleeve 620 Hose stud 621 Steel tubing 6mm 2822 Blanking plug 323 Pipe clip 1024 Grease cartridge 1
-
35 36
Positive D
isplacement
Injector (PD
I) System
for S
mall-M
edium M
achines
This pump is small, law cost, and only for our LHL original cartridge grease.
Dimensional drawing
S SeriesElectric Pump for LHL
SpecificationsHOW to order
● Related parts
Pressure gauge:P.85
GPL Pressure Switch:P.62
Adapter assemblies:P.185
Main tubing:P.174
P-107
WithWithout
Feed button
FWithout
[P-107]
AUTOMATIC LUBRICATORMODEL P-107VOLTAGE DC24VRATED CURRENT1.2A(MAX)DIS.PRESSURE 5.0MPaDIS.VOLUME 7ml/minCODE NO. 101003
MADE IN JAPAN
OPERATIONCAUTION
注 意
Pay attention yo the polarity upon wiring the power to the pump.Use the specified cartridge (LHL) only.
If other lubricant than LHL is used,it woulddamage not only the system components,butalso the important parts of your machine.
ポンプ電源には極性があります。配線時は必ず(+)(-)を確認してください。必ず、当社指定の専用カートリッジ(LHL)を使用してください。
LHL以外を使った場合、この装置のシステムを破損させるのみならず、機械の重要な部品も破損させます。
■■
■■
注 意油 的電源有極性、接線時必須要確認 (+)(-)極■
■石水
必須要使用我公司指定的専用油脂(LHL)如使用LHL以外的油脂、不只此装置会被損壊、機器上的重要零件也会被損壊。
Installation hole 34-φ7
Air bleeding plug
Discharge port Rc1/8
Sticker
Sticker
97
201
38
64.6
100
7.5 8
20 2145
122
Operation Lump
Specifications Sticker
Terminal
Cover fixing screw
Serial No.
Hydraulic circuit diagram
Cartridge grease
Depressing port
Air bleeding valve
LHL:P.82
Without feed button
With feed button
Pump stopping signal
Level switch
Pump stopping signal output
Pump stopping signal output
COM
COM
Level switch output
Level switch output
GND(-)
DC24V(+)
Output
Output
Output
Input
Input
InputGND(-)
DC24V(+)
Manual Switch
Ground
Ground
Wiring diagram P-Pump motion control flowchart
P-Pump Motion Control Flowchart Turn on the power
Yes
No
NoNo
No
No
No
Yes
Yes Yes
Yes
Yes Change the grease cartridge
Change the grease cartridge
Pump trouble
Is there grease level signal?
Is there pump stopping signal?
Is there pump stopping signal?
Start the pump
Pump trouble
Pump pressurisation trouble
Observe the pump working time Without pump stopping signal
Pump observing time depends on size of the system.Pump pressurising time depends on size of the system.
With pump stopping signalObserving pump pressurising time
Is there grease level signal?
Is there pump stopping signal? Turn off the pump, and take interval time
Is there pump stopping signal?
MDS valve:P.55
MU valve:P.53
MUJ junction:P.54
Power DC24V Power Consumption 24W Discharging pressure 5MPa Discharging time No restrictionInterval time More than 10 secondsWiring method Terminal connectionManual override switch With (Optional)Grease level switch WithCover Non combustible plastic (UL94-V0) CE approval With
Pump air bleeding No restriction
Directions for use
• Usage cartridge: LHL • Use LUBE original LHL cartridge• When the cartridge is changed, pay attention that foreign particle is
getting inside.• Do not discharge continuously.• After changing the cartridge, bleed the air inside the pump opening
the air bleeding valve.
-
37 38
Positive D
isplacement
Injector (PD
I) System
for S
mall-M
edium M
achines
80
126 218
104
241
2525
2722
25
13 3
234141
22
Below 7m 30s
Air bleeding valve
Main tube discharging port (PDI) Rc:1/8Pressure progressive discharging port Rc:1/8
80
126 218
104
241
2525
2722
25
13 3
234141
22
Below 7m 30s
Air bleeding valve
Main tube discharging port (PDI) Rc:1/8Pressure progressive discharging port Rc:1/8
Relief Valve
M
Solenoid Valve
Main tube discharging port (PDI) Rc:1/8
Pressure progressive discharging port Rc:1/8
Cartridge grease
Cartridge grease
Relief Valve
Solenoid Valve
Air bleeding valve
Air bleeding valve
Main tube discharging port (PDI) Rc:1/8
Dimensional drawing
EGM ⅡPositive Displacement Injector Electric Pump
This pump is small, law cost, and only for our original cartridge grease.
SpecificationsHOW to order
EGM 4 7CLⅡ (LHL)※②: Only if it’s 8MPa.
※If it’s 8MPa, it must be only Positive Displacement Injector(PDI) System
ST
Positive Displacement Injector(PDI) SystemPositive Displacement Injector(PDI) System and Progressive System
※ If it is T-type, it hasn’t got manual override switch.
8108MPa (Only for LHL System)10MPa
WithWithout
Feed button
FWithout
[EGM Ⅱ]
Hydraulic circuit diagram
● T-type
● S-type
Without feed button
With feed button
GLSV
GLSV
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
24VDCInput
24VDCInput
Level SwitchOutput
Level SwitchOutput
FBFB
Manual Override SwitchOutput
M
M
Wiring diagram Grease level switch
With grease level switch
[EGMⅡ-10S-4-7CLEB]
[EGMⅡ-10T-4-7CL]
Directions for use
• Use recommended grease.• Never use molybdenum disulfide-contained grease.• Use lithium greases. (Contact us for consultation when other than
lithium grease is used.)• Do not use any greases containing substances that attack brass and
rubber.• When the cartridge is changed, pay attention that foreign
particle is getting inside.• Do not discharge continuously.• After changing the cartridge, bleed the air inside the pump
opening the air bleeding valve.
Power DC24V Power Consumption 45.6W
Discharging pressure8MPa (Only for LHL System)10MPa
Maximum discharging time Below 7m 30sInterval time 3 times discharging timeWiring method Terminal connectionManual override switch With(Optional: Only PDI system) ※1Grease level switch WithSolenoid cover Non combustible plastic (UL94-V0) CE approval With
Pump air bleeding With restriction
※1 Although the Manual Override Switch provides a dry contact to activate the pump, its capacity is not sufficient to sustain the power required to operate the pump. Therefore, the power needs to be provided directly to the pump from the machine control panel.
● Related parts
MG2 metering valve:P.57
MGI metering valve:P.59
Pressure gauge:P.85
GPL pressure switch:P.62
Adapter assemblies:P.185
MG2C metering valve:P.57
Main tubing:P.174
Hand grease gun:P.86
MGLA metering valve:P.61
LHL:P.82
LUBE original grease:P.81
JVPA junctions:P.58
-
39 40
Positive D
isplacement
Injector (PD
I) System
for S
mall-M
edium M
achines
● Related parts
MG2 metering valve:P.57
MGI metering valve:P.59
Pressure gauge:P.85
GPL pressure switch:P.62
Adapter assemblies:P.185
MG2C metering valve:P.57
Main tubing:P.174
Hand grease gun:P.86
MGLA metering valve:P.61
LHL:P.82
LUBE original grease:P.81
JVPA junctions:P.58
This pump is small, law cost, and only for our original cartridge grease.
Positive Displacement Injector Electric Pump
EGME Ⅱ
SpecificationsHOW to order
EGME 4 7CLⅡ (LHL)※②: Only if it’s 8MPa.
※If it’s 8MPa, it must be only Positive Displacement Injector(PDI) System
S
T
Positive Displacement Injector(PDI) System
Positive Displacement Injector(PDI) System and Progressive System
※ If it is T-type, it hasn’t got
manual override switch.
8
10
8MPa (Only for LHL System)
10MPa
With
Without
Feed button
FB
Without
[EGME Ⅱ]
With feed buttonWithout feed button
EGMEⅡ-S
EGMEⅡ-T
24VDCInput
Level SwitchOutput
Without feed button
GLSV
1 2 3 4 5 6
24VDCInput
Level SwitchOutput
M
GL
1 2 3 4 5 6
24VDCInput
Level SwitchOutput
GL
1 2 3 4 5 6
FB
FB
7 8
Manual Override SwitchOutput
[EGMEⅡ-10T-4-7CL]
[EGMEⅡ-10S-4-7CLEB]
Hydraulic circuit diagram
Relief Valve
M
Solenoid Valve
Main tube discharging port (PDI) Rc:1/8
Pressure progressive discharging port Rc:1/8
Cartridge grease
Cartridge grease
Relief Valve
Solenoid Valve
Air bleeding valve
Air bleeding valve
Main tube discharging port (PDI) Rc:1/8
● T-type
● S-type
Directions for use
• Use recommended grease.• Never use molybdenum disulfide-contained grease.• Use lithium greases. (Contact us for consultation when other than
lithium grease is used.)• Do not use any greases containing substances that attack brass and
rubber.• When the cartridge is changed, pay attention that foreign
particle is getting inside.• Do not discharge continuously.• After changing the cartridge, bleed the air inside the pump
opening the air bleeding valve.
Power DC24V Power Consumption 28.8W
Discharging pressure8MPa (Only for LHL System)10MPa
Maximum discharging time No restrictionInterval time More than 10 secondsWiring method Terminal connectionManual override switch With(Optional: Only PDI system) ※1Grease level switch WithSolenoid cover Non combustible plastic (UL94-V0) Protection class IP54
CE approval With
Pump air bleeding With restriction
※1 Although the Manual Override Switch provides a dry contact to activate the pump, its capacity is not sufficient to sustain the power required to operate the pump. Therefore, the power needs to be provided directly to the pump from the machine control panel.
Dimensional drawing
80
126 218
104
241
2525
2722
25
13 3
234141
22
Below 7m 30s
Air bleeding valve
Main tube discharging port (PDI) Rc:1/8Pressure progressive discharging port Rc:1/8
Wiring diagram Grease level switch
With grease level switch
80
126 218
104
241
2525
2722
25
13 3
234141
22
Below 7m 30s
Air bleeding valve
Main tube discharging port (PDI) Rc:1/8Pressure progressive discharging port Rc:1/8
-
43
44
44
44
44
45
Cartridge type grease pump YMTMulti-Port Centralized Lubrication SystemWhy grease cartridges ?Lube Original Grease Cartridge Specified for the YMT Centralized Lubrication SystemYMT pump controllerPumping unit
【YMT】
YMT
Multi-Port Centralized Lubrication System
-
43 44
Multi-P
ort Centralized
Lub
rication System
主配管脱圧作動型
定量バルブ
主配管脱圧作動型
定量バルブ
圧力進行作動型
定量バルブシステム
リューベ
オリジナルグリース
配管部品
周辺機器
リューベハイブリッド
集中潤滑システムLHL
Mounting Hole M5 x 4
Alarm Signal Input
Pump Power Output 24 VDC
Proximity Switch Input
Input Voltage 100 VAC to 200 VAC
115
90118.4
40 37.55525
YMTCartridge type grease pump
YMT is the only centralized lubrication system that offers grease cartridges suitable to lubricate industrial machines working in the various and yet severe environments.
Specifications
Terminal box
YMT Pump Controller
HOW to order
Hydraulic circuit drawing
CP
T T
11
2
2310
13
14
5
9
R1 R1AC100Vinput PL
P1 2
DC24VPS
YMT
Patlite
Emergency alarm output
YMT Pump
YMT T
68
Pumping unit
Capable of controlling up35Maximum 3Maximum 5
Discharge volume 2ml/min(539291)Discharge volume 3.9ml/min(539292)
Quantity of pumping unit 1~5
Controller:P.44
Cartridge:P.44
● Related parts
Adapter assemblies:P.185
Main tubing:P.174
Pneumatic pump for pail:P.86
SP series progressive valve:P.71
AP series progressive valve:P.71
Dimensional drawing
Multi-Port Centralized Lubrication System YMT
Lube Original Grease Cartridge Specified for the YMT Centralized Lubrication System(Less frequent replacement work required. Thanks to 4 liters large cartridge capacity.)
Why Grease Cartridges ?
1266
15.9 Power lamp
4-φ9Pump mountinghole
Discharge portPS/4
Alarm signal output, DIN connector
423
264
190
131
210
Pump power input 24 V DC, DIN connector
Cartridge cover tightening direction
Lube offers ferrography analysis to check lubrication conditions.* Free of charge for the first analysis.
Pressure Gauge
Steel Tubing
24VDC (Controller)
Capable of controlling up to 5 lines.
Series Progressive Valve (with the performance indicator pin) Model SP
Newly Developed Grease Pump : Model YMT
Advantages of LUBE Cartridge Pump● Significantly reduces grease refilling time comparing to the conventional reservoir pump.● Eliminates the introduction of air and/or foreign substances during storage and/or refilling.● Prevents mixing different kinds of grease which causes performance degradation and/or solidification of grease.● Prevents contamination to working environment around machines often seen during a messy refilling procedure for a conventional reservoir pump.
Cartridge CoverAll-weather reinforced plastic
4-Liter Grease Cartridge (Standard)Select the grease suitable for machine operation environment and conditions.
* Equipped with the original “Low Grease Level Switch”.
Grease cartridges are not only easy to replace but also prevent the introduction of air and/or foreign substances into the system during grease refilling, thus insuring a steady delivery of clean
grease to lubrication points. These are the reasons why we highly recommend the Lube grease cartridge pump system.
Discharge Pressure Rated 25MPa, Maximum 35Mpa
Discharge Volume 2ml/min. (with 6mm Dia. Pumping Unit)
Number of Pumping Unit
1 to 3 Units or 1 to 5 Units(The number of the pumping units varies depending on the model.)
Voltage 24VDC ± 10%
Reservoir Capacity 4 Liters Lube Original Grease Cartridge
Grease Specified grease for YMT (NLGI No. 000 to 2)
Alarm Output Grease Level Alarm , No Cartridge Alarm
Directions for use
• Use recommended greases• Never use molybdenum disulfide-contained grease• Use lithium greases. (Contact us for consultation when other than
lithium grease is used.)• Do not use any greases containing substances that attack brass and
rubber.• Avoid continuous operation
Model Part NumberYMT-TBOX 300423
Model Part NumberYMT-C-E-S-AC 300421-088-200
The original grease cartridges for LUBE centralized lubrication systems were developed from 30 years of trials and errors.
MP2
YM2
LHL300
LUL-2H
LBL-2
High-performance Grease for General Industrial Machines.
High Load and High Pressure Grease
High Temperature and Water Resistant Grease
Biodegradable Grease
LFL-H1Food Grade Grease Certified by
NSF as H1 Lubricant
Excellent in Lubricating Tight Lubrication Points with a Small Amount and Low System Pressure
Lithium-based grease for general industrial machines with extreme pressures property and a wide range of applica-tion.
Grease containing organic molybdenum with excellent heavy load carrying capacity, abrasion resistance and seizure resistance.
High-fluidity grease with excellent migration property and heavy load carrying capacity.
Grease for severe environments with excellent heat and water resistance.
Environmentally-friendly grease reducing soil and water pollution.
LFL-H1 is certified as a H1 grade lubricant by NSF, the organization approved by the ANSI, and safe to use in food, beverage and pharmaceutical industries.[H1 Grade Grease] is defined as the grease that is safe to be in accidental contacts with food.
Input Voltage AC100V, AC200V 50/60HzDischarge Volume Control Timer or Count
Discharge Time (Selectable by the Selecting Switch)1 to 99 minutes (1-minute step)Number of Count 1 to 99 counts (1-count step)Interval 1 to 99 hours (1-hour step)
Alarm Detection- Grease Level- No Cartridge- Pressure Alarm- Valve Malfunction (Count Mode only)
Alarm Signal Output Normally Open or Normally Closed Rated Load : 200V 2A or lessInput Signal Proximity Switch Number of Signal Input : 1 to 5Protection Class and Standards CE (Applied ), IP65
Controller Specifications
-
45
Positive Displacement Injector (PDI) System EGM(Cartridge type)
Positive Displacement Injector (PDI) System EGH
HEX27(85)M22x1.5
816
1010
M22X1.5
1
2127(28)
HEX14
R1/4 43
43
23 4-Rc1/4
522-R1/4
φ69
(33)
13
5716R1/4
φ27
φ27 φ22
8 Indication
G1/4
8 Indication
8 Indication
HEX27(85)M22x1.5 6 Indication
6 Indication
G1/46 Indication
68
Pumping unit
EGM-10S-4-7C
EGH-3P
EGH-4C
【Pump】
47
49
Model Part NumberPUY-6 539291
●Material: SCM435H
Model Part NumberBPY 530911
●Material: A2011
Model Part NumberRTY 539310
●Material: S45C
Model Part NumberSCY 550130
●Material: SGP
Model Part NumberPUY-8 539292
●Material: SCM435H
Model Part NumberSWY 530910
●Material: Teflon
Model Part NumberJVY 530937
●Material: S45C
Model Part NumberGV50-R 500649
(Pump)
SCY
RTY
JVY
C I O S E
O P ERAT I ON
Assembly
Positive Displacement Injector (PDI) System for Small-Medium Machines
-
47 48
Positive D
isplacement
Injector (PD
I) System
for S
mall-M
edium M
achines
251
25109
141
Motor wiring(L=300)
Solenoid wiring(L=230)
179104 16
5925
(Sticker)
(Sticker)
4-φ9 Installation hole
Air bleeding valve
Discharge port Rc1/8
PumpDischarge volume 10mℓ/minDischarge pressure 10MPa
Power DC24V AC100V, 200V, φ1
Mortor 20W/0.8APressure relief solenoid 26W/1.1ATotal 46W/1.9A
Pressurization Max. ON time: 7.5 min.Power distribution rate Max.25% (20℃)Working consistency Cartridge grease No.000,00,0,1Recommended grease MP0, FS2, MT1Cartridge size 200mℓ , 400mℓ , 700mℓWeight 1.8kg (4C) , 2.8kg (7C)Pressure relief Built-in solenoid
EGMPositive Displacement Injector (PDI) System
SpecificationsHOW to order
[EGM-10S-4-7C][EGM-10S-4-4C]
Dimensional drawing
400
109
25
2559
(127) 176104 13
Air bleeding valve
Installation hole 4-φ9
Discharge port Rc1/8
222 25
127
104
176
5925
109
4-φ9 Installation hole
Air bleeding valve
Discharge port Rc1/8
(Sticker)
[EGM-10S-4-4C]
[EGM-10S-4-2C] [EGM-10S-4-7C]
Hydraulic circuit drawing
410SEGM C
200mℓ400mℓ700mℓ
247
Cartridge
Wiring diagram
M(White) (Black)
DC24V Input
Motor
+ ー
Solenoid(White) (Black)
(Thermal protector)
CartridgeRelief valve
Solenoid
Air bleeding valve
Discharge port Rc1/8
Motor driven piston pump
Directions for use
• Use recommended greases.• Never use molybdenum disulfide-contained grease• Use lithium greases. (Contact us for consultation when other than
lithium grease is used.)• Do not use any greases containing substances that attack brass and
rubber• When refilling, take care not let foreign matter in the grease.• Avoid continuous operation• When refilling grease in main pipe and during test operation, stick
to an intermittent cycle of running for 30 seconds and resting for 90 seconds. Failure to follow this requirement will result in thermal protector being activated by a heated solenoid, leaving the solenoid de-energized without pressure built up
● Related parts
MG2 metering valve:P.57
MGI metering valve:P.59
Pressure gauge:P.85
GPL pressure switch:P.62
Adapter assemblies:P.185
JVPA junctions:P.58
MG2C metering valve:P.57
Main tubing:P.174
MGLA metering valve:P.61
LHL:P.82
LUBE original grease:P.81
-
49 50
Positive D
isplacement
Injector (PD
I) System
for S
mall-M
edium M
achines
EGHPositive Displacement Injector (PDI) System
Compact, low-cost manually operated pump
Specifications
Hydraulic circuit drawing
ReservoirRefilling portRelief valve
Manual depressurized valve
Air bleeding valve
Reservoir type[EGH-3P]
Cartridge type[EGH-4C]
Dimensional drawing
Sticker
Discharge port(Rc1/8)
Filling port
3-φ9 Installation hole
Air bleeding valve
(9.5°)
(150)
9
336
253
75
70
(310)
(47.5°)
Handle lock
70
75
(336)
(310)
(47.5゚)
(150)
(9.5゚)
Sticker
3-φ9 Installation hole
Air bleeding valve
Handle lock
Discharge port(Rc1/8)
Reservoir type[EGH-3P]
Cartridge type[EGH-2C]
HOW to order
EGHReservoir type(260mℓ)Cartridge type(200mℓ)Cartridge type(400mℓ)
3P2C4C
Type of reservoir (effective capacity)
Cartridge type[EGH-2C]
70
75
394
Sticker
3-φ9 Installation hole
Air bleeding valve
Handle lock
Discharge port(Rc1/8)
(47.5゚)
(310)
(150)
(9.5゚)
Cartridge type[EGH-4C]
EGH-3P
PumpDischarge volume 1mℓ/strokeDischarge pressure 10MPa (safety valve set pressure)
Working consistency NLGI No.000、00、0、1 (lithium grease)Recommended grease MP0、FS2、MT1Cartridge size 260mℓWeight 1.4kgPressure relief Manual pressure relief leverEGH-2C EGH-4C
PumpDischarge volume 1mℓ/strokeDischarge pressure 10MPa (safety valve set pressure)
Working consistency Cartridge grease No.000、00、0、1 (lithium grease)Recommended grease MP0、FS2、MT1Cartridge size 200mℓ、400mℓ CartridgeWeight 1.4kgPressure relief Manual pressure relief lever
Directions for use
• Use recommended cartridge greases• Never use molybdenum disulfide-contained grease.• Use lithium greases.• Do not use any greases containing substances that attack brass and
rubber.• When refilling or replacing cartridge, take care not let foreign matter
in the grease or pump.• After refilling or replacing cartridge, always loosen the air bleed
valve to purge the pump of air.• Use the pressure relief lever correctly.
MGI metering valve:P.59
● Related parts
Pressure gauge:P.85
Adapter assemblies:P.185
Main tubing:P.174
Pneumatic pump for pail:P.86
Hand grease gun:P.86
MG2 metering valve:P.57
MG2C metering valve:P.57
LUBE original grease:P.81
JVPA junctions:P.58
-
Metering valves for LHL system MU・MDS
Junctions for MU・metering valve MUJ
Grease metering valve MG2・MG2C
Junctions for MG2・MG2C metering valve JVPA
Metering valve for grease with clogged line detection MGI
Metering valve for grease with performance monitor MGLA
Pressure switch for grease system GPL
Junction
MGI
MGLA
GPL
【Valve】53
55
57
58
59
61
62
63
JVPA
MG2・MG2C
MU・MDS
Positive Displacement Injector (PDI) System for Small-Medium Machines
-
53 54
Positive D
isplacement
Injector (PD
I) System
for S
mall-M
edium M
achines
Model Part NumberMU-BP 619840
●Material: Steel (SUM24)
Model Part NumberMU-SC 619841
●Material: Brass (C3604)
S Series MUMetering valves for LHL system
According to adopting reliable straight hydraulic system valves, straight connectors and one-touch nipples, connecting to junctions and piping are getting easier.
P-107:P.35
Pressure gauge:P.85
● Related parts
Main tubing:P.174
Adapter assemblies:P.185
Branch tubing:P.171
Compression parts:P.169
Adapters:P.175
KEN-T:P.188
KEN-M:P.188
Junctions for MU metering small sized valve
For MU small metering valve installation
Dimensional drawing
M10×1
M10×1
O-ring
O-ring
Rc1/8
28HEX12
5 16
Model
[Plug assembly]
[Connector assembly]
16
16
52
28.5
16
16
8.513
13
1010
1616.5 10
16.5
16.5
16.5
6.5
1033
23
3-M10×1
M10×1
L1
L2
Valve assembly port
Pipe connection
632-Rc1/8
R3.25
2-Rc1/8
6.5
[Junction MUJ-3S]
Specifications Model
Dimensional drawingOperation chart
M10×1
M10×1
M10×1
O-ring
O-ring
O-ring
M8×1 (φ4 tubing) M8×1 (φ4 tubing)
HEX11
HEX10
HEX11
HEX10
HEX11
HEX10
37.4
41.4
46.7
Discharge
volume
Production
lot Production
lot
Production
lot
Discharge
volume
Discharge
volume
5 10E
5 10E 5 10E
[MU-20N][MU-5N][MU-5]
Start of pum
p operation
Start of pressure rise
Valve opens
Pump stops
Inner pressure discharge
Return of valve position
Operation com
pleted
Pressure starts rising before discharge(start of pressure build up)
Pump operation Not in operation
Pressurizing
Discharging
Discharge of grease completed(maximum pressure)
Upper chamber being filled(piston returning)
[Junction MUJ-2D]
Operating pressure 1.5MPaReset pressure 0.4MPa
Model Part Number Specifilcation L1 L2MUJ- 1S 216101 Single type for 1 port 31 20MUJ- 2S 216102 Single type for 2 ports 47 36MUJ- 3S 216103 Single type for 3 ports 63 52MUJ- 4S 216104 Single type for 4 ports 80 68MUJ- 5S 216105 Single type for 5 ports 96 84MUJ- 6S 216106 Single type for 6 ports 112 100MUJ- 7S 216107 Single type for 7 ports 128 116MUJ- 8S 216108 Single type for 8 ports 144 132MUJ- 9S 216109 Single type for 9 ports 160 148MUJ-10S 210110 Single type for 10 ports 175 164
Model Part Number Specifilcation L1 L2MUJ- 2D 216121 Double type for 2 ports 31 36MUJ- 4D 216122 Double type for 4 ports 47 52MUJ- 6D 216123 Double type for 6 ports 63 68MUJ- 8D 216124 Double type for 8 ports 79 84MUJ-10D 126125 Double type for 10 ports 95 100MUJ-12D 216126 Double type for 12 ports 111 116MUJ-14D 216127 Double type for 14 ports 127 132MUJ-16D 216128 Double type for 16 ports 143 148
●Material: Aluminium (A6063S-T5)
Model Part Number Didcharge volume (mℓ) L (mm) MarkMU-5 205872 0.05
37.45
HEX12
MU-10 205873 0.1 10MU-20 205874 0.2 50.4 20MU-5N 205912 0.05
41.45
MU-10N 205913 0.1 10MU-20N 205914 0.2 54.4 20MU-5C 205922 0.05
46.75
MU-10C 205923 0.1 10MU-20C 205924 0.2 59.7 20
-
55 56
Positive D
isplacement
Injector (PD
I) System
for S
mall-M
edium M
achines
P-107:P.35
Pressure gauge:P.85
● Related parts
Main tubing:P.174
Adapter assemblies:P.185
Branch tubing:P.171
Compression parts:P.169
Adapters:P.175
KEN-T:P.188
KEN-M:P.188
Junction header
Junction header
Junction header
MDP valve
MDP valve
MDP valve
MDP valve
Junction header
Specifications Model
Dimensional drawing
R1/8(Lubrication point side)
R1/8(Junction side)
Production lot
HEX12
12
36.5
Discharge volume 5 9K
R1/8(Lubrication point side)
M8×1 (φ4 tubing)(Compression nut) M8×1 (φ4 tubing)(Compression nut)
Production lot
HEX12
39.5Discharge volume 5
9K
R1/8(Lubrication point side)
R1/8(Junction side)
Production lot
33
27
Discharge volume 5 9K
12
R1/8(Lubrication point side)
Production lot
36
30
Discharge volume
5 9K
[MDP-5S][MDP-5HE][MDP-5HS] [MDP-5E]
Example
Operating pressure 1.5MPaReset pressure 0.4MPa
Model Part Number Didcharge volume (mℓ) L (mm) MarkMDP- 3S 205891 0.03
39.53
MDP- 5S 205892 0.05 5MDP-10S 205893 0.1 10MDP- 3E 205896 0.03
363
MDP- 5E 205897 0.05 5MDP-10E 205898 0.1s 10MDP- 3HS 205901 0.03
36.53
MDP- 5HS 205902 0.05 5MDP-10HS 205903 0.1 10MDP- 3HE 205906 0.03
333
MDP- 5HE 205907 0.05 5MDP-10HE 205908 0.1 10
S Series MDSMetering valves for LHL system
Metering Direct Plunger MDP) is connected to lubrication points, and all troubles which are clogging, break and leak, are eliminated. Furthermore, according to check the pressure in main tubing, you can realize appropriate small volume lubrication and system error.
Planning to start selling in April. 2011
-
57 58
Positive D
isplacement
Injector (PD
I) System
for S
mall-M
edium M
achines
M12×1
φ4 Nylon tubing
LHEX12
□10
5 3A
M12×1
O-ringO-ring
M8×1 (φ4 tubing)
LHEX12
□10
50 3A
Discharge volume
Discharge volume
Production lot
Production lot
● Related parts
[MG2・MG2C]
EGM-10S-4-7C:P.47
EGH-3P:P.49
EGH-4C:P.49
Pressure gauge:P.85
Main tubing:P.171
Branch tubing:P.171
Adapter assemblies:P.185
Compression parts:P.169
Adapters:P.175
KEN-T:P.188
KEN-M:P.188
For piping connection parts, see P. 51
Junctions for MG2・MG2C metering For MG2・MG2C metering valve installation
Dimensional drawing
M12×1
O-ringRc1/8
24HEX12
M12×1
O-ring5 14
Model
[Plug assembly]
[Connector assembly]
12-M12×1
L2L1
L2L1
2ーφ7
16 16
16
16 16 16
2-M12×1
2ーφ7
10.5
17.57
202-Rc1/8
1135
15
202-Rc1/8
Clamp face
Clamp face
1125
15
[Junction JVPA-12D]
[Junction JVPA-2S]
Specifications Model
Dimensional drawing
[MG2]
Operation chart
Start of pump operation
Start of pressure rise
Valve opens
Pressure starts rising beforedischarge of grease
①Before the discharge(Start of pressure rise)
②Pump pressurizingCompletion of discharge (under pressure)
③Measuring(piston returning)
Valve begins todischargeDischarge
O-ringCollarA
Check valve
Inner pressure discharged
Depressed
Pump operation Pump stops
Pump relief opens
Pump stops
Inner pressure discharged
Return of valve piston
Finish
O-ring and collar go up and push up the grease (oil) in the measuring chamber.
Spring starts pushing down O-ring and collar. In the meantime, the path (A) opens up and the rip of the check valve seals the path from the junction. Grease (oil) moves to the measuring chamber.
[MG2C]
Grooving
※Grease valve has the grooving as shown in the picture.
Operating pressure 2.5MPaReset pressure 1.4MPa
Model Part Number Didcharge volume (mℓ) L (mm) MarkMG2-3 205741 0.03
483
HEX12
MG2-5 205742 0.05 5MG2-10 205743 0.1 10MG2-20 205744 0.2
6420
MG2-30 205745 0.3 30MG2-50 205746 0.5 50MG2C-3 205731 0.03
53.53
MG2C-5 205732 0.05 5MG2C-10 205733 0.1 10MG2C-20 205734 0.2
69.520
MG2C-30 205735 0.3 30MG2C-50 205736 0.5 50
Model Part NumberSCP 619803
●Material: Brass (C3604)
Model Part NumberBPP 619802
●Material: Steel (SUM24)
Model Part Number Specifilcation L1 L2JVPA- 1S 216001 Single type for 1 port 33 22JVPA- 2S 216002 Single type for 2 ports 49 38JVPA- 3S 216003 Single type for 3 ports 65 54JVPA- 4S 216004 Single type for 4 ports 81 70JVPA- 5S 216005 Single type for 5 ports 97 86JVPA- 6S 216006 Single type for 6 ports 113 102JVPA- 7S 216007 Single type for 7 ports 129 118JVPA- 8S 216008 Single type for 8 ports 145 134JVPA- 9S 216009 Single type for 9 ports 161 150JVPA-10S 216010 Single type for 10 ports 177 166JVPA-11S 216011 Single type for 11 ports 193 182JVPA-12S 216012 Single type for 12 ports 209 198
Model Part Number Specifilcation L1 L2JVPA- 2D 216021 Double type for 2 ports 33 11JVPA- 4D 216022 Double type for 4 ports 49 38JVPA- 6D 216023 Double type for 6 ports 65 54JVPA- 8D 216024 Double type for 8 ports 81 70JVPA-10D 216025 Double type for 10 ports 97 86JVPA-12D 216026 Double type for 12 ports 113 102JVPA-14D 216027 Double type for 14 ports 129 118JVPA-16D 216028 Double type for 16 ports 145 134
●Material: Aluminium (A6063S-T5)
MG2・MG2CGrease metering valve
According to adopting reliable straight hydraulic system valves, straight connectors and one-touch nipples, connecting to junctions and piping are getting easier.
-
59 60
Positive D
isplacement
Injector (PD
I) System
for S
mall-M
edium M
achines
MGIMetering valve for grease with clogged line detection
When grease line is clogged at a lubrication point, a red pin pops up to tell the problem.
Nipple
Main body
Thread part(Use sealing compound)
Dimensional drawing
R1/8
12
Use sealing compound (Red)Mark
40 5M8×1 (φ4 tubing)
L
8
JV
MGI
JV 5S 10 20 30MGI
①
①
10
Junction typeMark of the valve (from upper left side)
Valve
② ③ …
②
20
③
30Write the mark of the valve which you would like, from left to right with numerical sequence.(If it’s double junction, write from top to bottom) ※ Mark indicates discharge volume (Ex. 50→0.5cc/stroke)
Example)
Ordering methodSpecifications
Model
● Related parts
JV Junction:P.63
Pressure gauge:P.85
Main tubing:P.171
Adapter assemblies:P.185
Branch tubing:P.171
Compression parts:P.169
Adapters:P.175
KEN-T:P.188
KEN-M:P.188
MGI valve
MG (MGA) valve
MGAC valve
A
S81-SC Connectors: Straight
JV Junction
ST-8ZMain tubing φ8
BP-1Blanking plug
EA4-20Elbow adapter
CB-4-8Bushing KEN-M
Discharging detection pin
KEN-TDischarging detection pin
CS-4Sleeve
SA4-16Straight adapter
ST-4Zφ4 Copper piping
NT-4φ4 Nylon tubing
T
B
T
T
T
Piping layout (Example)
[JV-4S-MGI-10-10]
EGM-10S-4-7C:P.47
EGH-3P:P.49
EGH-4C:P.49
Model Part Number Didcharge volume (mℓ) L (mm) MarkMGI-3 205174 0.03
66.53
MGI-5 205175 0.05 5MGI-10 205176 0.1 10MGI-20 205177 0.2
7420
MGI-30 205178 0.3 30MGI-50 205182 0.5 85.5 50
Operating pressure 1.5MPaReset pressure 0.5MPaDetection pin operating pressure 1.5MPa
※ Material: Brass
Directions for use
• When installing the valve on a junction side, screw it into place with a wrench applied to the valve body.
• When connecting the valve to piping, turn bushing holding nipple with a wrench.
At this mark, use sealing compound at the point.
At this mark, it means tightening torque (See the mark in tightening torque chart on P. 261).
-
61 62
Positive D
isplacement
Injector (PD
I) System
for S
mall-M
edium M
achines
● Related parts
Pressure gauge:P.85
Main tubing:P.171
Adapter assemblies:P.185
Branch tubing:P.171
Compression parts:P.169
Adapters:P.175
KEN-T:P.188
KEN-M:P.188
EGM-10S-4-7C:P.47
EGH-3P:P.49
EGH-4C:P.49
● Related parts
Pressure gauge:P.85
Main tubing:P.171
Adapter assemblies:P.185
Branch tubing:P.171
Compression parts:P.169
Adapters:P.175
KEN-T:P.188
KEN-M:P.188
EGM-10S-4-7C:P.47
EGH-3P:P.49
EGH-4C:P.49
Discharge volume 0.1、0.2、0.3、0.5mℓ/strokeOperating pressure 2.5MPaReset pressure 1.2MPa
Contact capacity AC125V 2A AC250V 2ADC30V 2A Material:Zinc Die Casting (ZDC)
Operating pressure 3.0MPa±20%Reset pressure 2.5MPa±20%Max. working pressure 10MPa
Micro switch spec
Rated voltage AC250V, DC30VResistance load 2A(AC250V, DC30V時)Service life: 200,000 switchings (loaded)Structrual protection:
JIS moisture-tight, conforming to IEC IP67
Operating pressure 5.5MPa±0.4MPa
Micro switch spec
Rated voltage AC250V, DC30VResistance load 2A(AC250V, DC30V時)Service life: 200,000 switchings (loaded)Structrual protection:
JIS moisture-tight, conforming to IEC IP67
※ Production lot indicates bottom number of the year and month. [A(January)~L(December)]
MGLAMetering valve for grease with performance monitor
You can check each discharge electrically with this metering valve. It’s especially suitable for the most important lubrication points, and as you use at the longest lubrication piping point, you can check if the main piping is pressurized and depressurized correctly. As you count the operating frequency, you will know the time to change the cartridge and total lubrication volume of the cartridge.
Wiring diagram
COM
Blac
NO
White
NC
Red
Contact type
Dimensional drawingSpecifications
Model(290)
122
58.5
11.5
34.5
30
252-Rc1/8
Discharge portRc1/8
Mark
18
[MGLA]
GPLPressure switch for grease system
It’s not a current pressure switch, but grease doesn’t stay inside piping, so it’s highly reliable and long lasting. Don’t connect at the end of main tubing.
Dimensional drawingSpecifications
Model
(290)(10)
85.5
26
55 2-Rc1/8
32
9
227.5
12.5
23.5
30.5
5
7A
Type Production lot
Wiring diagram
COM
Blac
NO
White
NC
Red
Contact type
[MGLA-20]Material: Zinc Die-casting (ZDC)
[GPL-30]
GPL-55
Model Part Number Didcharge volume (mℓ) MarkMGLA-10 205515 0.1 10MGLA-20 205518 0.2 20MGLA-30 205588 0.3 30MGLA-50 205589 0.5 50
Model Part NumberGPL-30 209282GPL-55 209392
MGLA
GPL-30
GPL-55
Directions for use
• Disconnect from the piping when you don’t use. If you plug it onto the discharge port, it can be clogging and so on.
-
63
20.58
2-Rc1/8
29
φ16
φ7φ11
8
2-Rc1 8/
206470-M.AI
33
φ16
8
20.5
φ7
3-Rc1/8
16.5
24.5
35 10.5
φ74-Rc1/8
33
11
1520
φ11
20.5
8
4-Rc1/8
10.5
16
φ11
16.5
φ16
2-φ7
L2L1
35 10.5
16 16
1620
2ーφ7 8-RC 18/
206466-M.AI
L2L1
φ11
ModelDimensional drawing
Junction
For main piping, separating and MGI metering valve installation
[JV-4S]
[JV-8D]
[JV-6S]
GMNH-4-7C
EGH-4C
Progressing electric pump GMNH
Progressing manual pump EGH
【Pump】
65
67
Model Part Number Specifications L1 L2JV- 4S 206472 Single type for 2 ports 49 38JV- 5S 206473 Single type for 3 ports 65 54JV- 6S 206474 Single type for 4 ports 81 70JV- 7S 206475 Single type for 5 ports 97 86JV- 8S 206476 Single type for 6 ports 113 102JV- 9S 206479 Single type for 7 ports 129 118JV-10S 206543 Single type for 8 ports 145 134
●Material: Zinc Die-casting (ZDC)
Model Part Number SpecificationsJV-3 206471 Single type for 1port
●Material: Zinc Die-casting (ZDC)
Model Part NumberJV-2 206470
●Material: Zinc Die-casting (ZDC)
Model Part Number SpecificationsJV-4D 206464 Double type for 2 ports
●Material: Brass (C3604)
Model Part Number Specifilcation L1 L2JV- 6D 206465 Double type for 4 ports 49 38JV- 8D 206466 Double type for 6 ports 65 54JV-10D 206467 Double type for 8 ports 81 70JV-12D 206468 Double type for 10 ports 97 86JV-14D 206469 Double type for 12 ports 113 102
●Material: Brass (C3604)
Series Progressive System for Small-Large Machines
-
65 66
主配管脱圧作動型
定量バルブ
マルチポート
集中給脂システム
主配管脱圧作動型
定量バルブ
圧力進行作動型
定量バルブシステム
リューベ
オリジナルグリース
配管部品
周辺機器
リューベハイブリッド
集中潤滑システムLHL
Series P
rogressive S
ystem for S
mall-Large
Machines
(t=3.2)
21100 70 8
825
(239)
128 8
391
250
Air bleeding valve
Installation hole 5-φ9
Discharge port Rc1/8
Specifications
GMNH(High pressure type)Series Progressive System motorized grease pump
Motor-driven cartridge grease pump. Use with progressive metering valves makes possible discharge volume adjustment according to pump operation time.
Dimensional drawing
Wiring diagram
●Condenser4 3 2 1
4 3 2 1
Condenser
Connecting diagram
Terminal box inside
Power
AC100V 6μF(GMNH-1-4C、GMNH-1-7C)
AC200V 1.5μF(GMNH-2-4C、GMNH-2-7C)
[GMNH-4-7C] [GMNH-1-7C・GMNH-2-7C]
「GMNH-4-4C] [GMNH-1-4C・GMNH-2-4C]
Air bleeding valve
70 75128171
8 8
825
391
Installation hole4-φ9
Discharge portRc1/8
(345)
250
[GMNH-4-4C] [GMNH-2-4C・GMNH-1-4C]
310
258
(20.5)70
197
875
133.5
(345)
Air bleeding valveInstallation hole 4-φ9
Discharge port Rc1/8
310
(t=3.2)
23100 70 (23)257
825
133.575 8
Air bleeding valve
Installation hole 5-φ9
Discharge port Rc1/8
[GMNH-4-7C] [GMNH-1-7C・GMNH-2-7C]
Hydraulic circuit drawing
Reservoir
M
Relief valve
brush motor
SP series progressive valve:P.71
Pressure gauge:P.85
● Related parts
Adapter assemblies:P.185
Main tubing:P.171
HOW to order
AP series progressive valve:P.71
GMNH CCartridge typeC
Cartridge type
400mℓ700mℓ
47
AC100VAC200VDC24V
124High pressure type
Cartridge
Voltage
LUBE original grease:P.81
PumpDischarge volume 10mℓ/minDischarge pressure 20MPa (safety valve set pressure)
MortorPower DC24Vφ 1/0.65A AC100Vφ 1/0.65A AC200Vφ 1/0.65AOutput 15W DC brush motor 25W ignition motor
Working consistency Cartridge grease No.000,00, 0, 1 (lithium grease)
Recommended grease MP0, MP1, FS2
Cartridge size 400mℓ, 700mℓWeight 2.8kg (DC24V), 3.1kg (AC100V, 200V)
Directions for use
• Use recommended greases.• Never use molybdenum disulfide-contained grease• Use lithium greases. (Contact us for consultation when other than lithium grease is used.)• Do not use any greases containing substances that attack brass and rubber.
-
67 68
主配管脱圧作動型
定量バルブ
マルチポート
集中給脂システム
主配管脱圧作動型
定量バルブ
圧力進行作動型
定量バルブシステム
リューベ
オリジナルグリース
配管部品
周辺機器
リューベハイブリッド
集中潤滑システムLHL
Series P
rogressive S
ystem for S
mall-Large
Machines
70
75
394
Sticker
Discharge port(Rc1/8)
3-φ9(Installation hole)
Air bleeding valve
Handle lock
(47.5゚)
(310)
(150)
(9.5゚)
70
75
(336)
(310)
(47.5゚)
(150)
(9.5゚)
Sticker
Discharge port(Rc1/8)
3-φ9(Installation hole)
Air bleeding valve
Handle lock
Dimensional drawing
Specifications
HOW to order
EGHReservoir type(260mℓ)Cartridge type(200mℓ)Cartridge type(400mℓ)
3P2C4C
Type of reservoir (effective capacity)
EGHSeries Progressive System manual grease pump
Hydraulic circuit drawing
Cover
Follow plate
ReservoirRefilling portRelief valve
Manual depressurized valveManual depressurized valve
Air bleeding valve
Reservoir typeEGH-3P
Cartridge typeEGH-2C
Cartridge typeEGH-4C
Sticker
Discharge port(Rc1/8)
Filling port
3-φ9(Installation hole)
Air bleeding valve
(9.5°)
(150)
9
336
253
75
70
(310)
(47.5°)
Handle lock
Reservoir type[EGH-3P]
Cartridge type[EGH-2C]
Cartridge type[EGH-4C]
Compact, low-cost manually operated pump
SP series progressive valve:P.71
Pressure gauge:P.85
● Related parts
Adapter assemblies:P.185
Main tubing:P.171
Pneumatic pump for pail:P.86
AP series progressive valve:P.71
Hand grease gun:P.86
LUBE original grease:P.81
EGH-3P
PumpDischarge volume 1mℓ/strokeDischarge pressure 10MPa (safety valve set pressure)
Working consistency NLGI No.000、00、0、1 (lithium grease)Recommended grease MP0、FS2、MT1Cartridge size 260mℓWeight 1.4kgPressure relief Manual pressure relief leverEGH-2C EGH-4C
PumpDischarge volume 1mℓ/strokeDischarge pressure 10MPa (safety valve set pressure)
Working consistency Cartridge grease No.000、00、0、1 (lithium grease)Recommended grease MP0、FS2、MT1Cartridge size 200mℓ、400mℓ CartridgeWeight 1.4kgPressure relief Manual pressure relief lever
Directions for use
• Use recommended cartridge greases• Never use molybdenum disulfide-contained grease.• Use lithium greases.• Do not use any greases containing substances that attack brass and
rubber.• When refilling or replacing cartridge, take care not let foreign matter
in the grease or pump.• After refilling or replacing cartridge, always loosen the air bleed
valve to purge the pump of air.• Use the pressure relief lever correctly.
-
Series progressive valve AP、SP
【Valve】71
AP-6K
SP-8
Series Progressive System for Small-Large Machines
-
71 72
主配管脱圧作動型
定量バルブ
マルチポート
集中給脂システム
主配管脱圧作動型
定量バルブ
圧力進行作動型
定量バルブシステム
リューベ
オリジナルグリース
配管部品
周辺機器
リューベハイブリッド
集中潤滑システムLHL
Series P
rogressive S
ystem for S
mall-Large
Machines
Dimensional drawing
This is just an example
7.530
2
4
1
3
Grease inletRc1/8
(4-M10×1)
L
4.5
1515
20
83(90.5)
60 2-φ5.5
Indicator pin
2
4
65
87
1
3
5.5
20
75(103.5)
60 2-φ5.57.5
30
Discharge port
Discharge port (6-M10×1)
6015
1515
Grease inletRc1/8
Outlet sleeveM12 type proximity sensor can install here
M12×1
24
68
10
13
57
911
12
ST-6Zφ6 Steel tubing SPA-4
166005φ6 Steel tubing
S61-SC、S62-SC Adapter assemblies
CB-4、CS-4 Compression parts
E61-SC(E81-SC) Adapter assemblies
E61-SC、E62-SC Adapter assemblies
ST-6Zφ6 Steel tubing
SW-10207611Sealing washer
SPC611677Clamping ring
SPN611784Nut
SPS611695Outlet sleeve
SPB611785Plug
SPA-6Outlet check body
ST-6Z φ6 Steel tubing(ST-8Z φ8 Steel tubing)
SS
T
T
N
[SP-4K] [AP-6S]
Specifications Model
AP・SPSeries Progressive Valve
Valve performance according to indicator pin movement can be electrically monitored through proximity sensor.
Original prts
● Related parts
S: With proximity sensor adaptorK: With indicator pin※ L: See dimensional drawing.
Adapter assemblies:P.185
Compression parts:P.169
Adapters:P.175
KEN-T:P.188
KEN-M:P.188
※ CAUTION Do not use plug SPB for discharge port 1and 2 by any means.
[SP-8][AP-6]
GMNH-4-7C:P.65
EGH-3P:P.67
EGH-2C:P.67
EGH-4C:P.67
Pressure gauge:P.85
Main tubing:P.171
Branch tubing:P.171
Model Part NumberSPB 611785SW-10 207611SPC 611677SPA-6 619780SPS 611695SPN 611784SPA-4 166005
Discharge volume 0.2mℓ/strokeDischarge port Tube of 6mm, 4mm O.D usedGrease inlet Rc1/8Max. working pressure 20MPaMinimum operating pressure 2MPaWorking consistency NLGI No.000~2Performance monitor Indicator pin (K type)
MaterialAP:Aluminum Die-castSP:Aluminum
Model Part Number No. of discharge portsAP-4K 205680
4AP-4 205690AP-6K 205681
6AP-6 205691AP-6S 205686AP-8K 205682
8AP-8 205692AP-8S 205687AP-10K 205683
10AP-10 205693AP-10S 205688AP-12K 205684
12AP-12 205694AP-12S 205689
Model Part Number No. of discharge portsSP-4K 205530
4SP-4 205540SP-6K 205531
6SP-6 205541SP-6S 205536SP-8K 205532
8SP-8 205542SP-8S 205537SP-10K 205533
10SP-10 205543SP-10S 205538SP-12K 205534
12SP-12 205544SP-12S 205539
At this mark, use sealing compound at the point.
At this mark, it means tightening torque (See the mark in tightening torque chart on P. 261).
-
73
Setting of discharge volume/ Suggestions
Step1
The grease is sent by the pump or the grease gun enters from the in let of the block upper part. The sent grease passes along the port shown in the deep color, reaches the right-hand side of a piston "A", and moves piston "A" leftward. At this time, the grease on the left-hand side of a piston "A" passes along the port shown in the thin color, and is breathed out from the outlet of No. 2.
If a piston "A" carries out a full stroke leftward, as shown to Fig. 2 by the deep color, the port which results in surface of a piston "B" will be connected, and the grease from a pump will move a piston "B" leftward through this port. At this time, the grease on the left-hand side of a piston "B" is breathed out from the outlet of No. 7 through the port shown in the thin color.
Like last time, if a piston "B" carries out a full stroke leftward, as shown to Fig. 3 by the deep color, the port which results in right-hand side edge of a piston "C" will be connect, grease will pass along this port, and a piston "C" will be moved leftward. At this time, the grease on the left-hand side of a piston "C" is breathed out from a No. 5 outlet through the port shown in the thin color.
If a piston "C" carries out a full stroke, as shown by the deep color among the right figure, the port which results in right-hand side edge of a piston "D" will be connected, and a piston "D" will be moved leftward. At this time, the grease on the left-hand side of a piston "D" is breathed out from a No. 3 outlet through the port shown in the thin color.
This time, as a result of a piston's "D'"' carrying out a full stroke, as shown by the deep color among the figure, the port which results in left-hand side edge of a piston "A" is connected, and a piston "A" is moved rightward. At this time, the grease on the right-hand side of a piston "A" which worked as last operation oil is breathed out from a No. 1 outlet through the port shown in the thin color.Grease will be exposed by the same repetition as henceforth in order of the outlet of 8, 6, 4, 2, 7, 5, 3, and 1.
7
5
3
1
8
6
4
2
A
B
C
D
Grease inlet
Fig1
1
3
5
7
2
4
6
8A
B
C
D
Grease inlet
Fig27
5
3
1
8
6
4
2
A
B
C
D
Grease inlet
Fig3
Fig5
7
5
3
1
8
6
4
2
A
B
C
D
Grease inlet
Fig47
5
3
1
8
6
4
2
A
B
C
D
Grease inlet
Step3
Step5
Step2
Step4
● Suggestions1. Use only an exclusive joint for discharge port of SP type valve.2. When you attach the dischagre port nipple with a check of an exclusive joint in grease
dischagre Port, please be sure to check whether the bypass hole interception ring is set.Moreover, when you attach a plug in grease dischagre port, please be sure to remove a bypass hole interception ring.If a plug is attached with a bypass hole interception ring set, the whole valve stops operating.
3. Fasten more strongly some dischagre port nipples with a check, or compression nuts so that a bypass hole interception ring is set certainly.
4. The case where an exclusive joint is attached to discharge port of grease -- the upper and lower sides -- either -- please construct in an order from the direction of an end. If it begins to construct from middle discharge port or the middle is flown, a spanner will not fully turn and will not be attached.
5. When you attach a plug to grease discharge port, please fasten more strongly.
Operation chart
● Setting of discharge volumeAs for each discharge port, 0.2 ml/stroke grease is breathed out at the time of a pump operation.
If one discharge port is closed, the quantity to have closed will be added and breathed out by the next discharge port.
Exmple4
×-7
×-5
×-3
/ 148
8-×
4-×
2 /28
6 /28
Example
× : It does not breathes out.1 : One 4 times the quantity of this breathes out.2, 6 : A twice as many quantity as this breathes out.
Motorized grease pump EGM-T EGME-T
【Pump】
75
77EGM-T
EGME-T
Compatible with Both PDI and Series Progressive Metering Valve System for Small-Medium Machine
-
75 76
主配管脱圧作動型
定量バルブ
マルチポート
集中給脂システム
主配管脱圧作動型
定量バルブ
リューベ
オリジナルグリース
配管部品
周辺機器
リューベハイブリッド
集中潤滑システムLHL
Compatible with Both PDI and
Series Progressive Metering Valve
System for Sm
all-Medium
Machine
(Sticker)
(Sticker)
25125
109
141179104 16
5925
4-φ9 Installation hole
Air bleeding valve
PDI Discharge port Rc1/8
Series progressive valve port Rc1/8
Dimensional drawing
[EGM-10T-4-7C]
SpecificationsHOW to order
Wiring diagram
DC24V Input
+ ー
Solenoid(White) (Black)(Thermal protector)
M(White) (Black)
DC24V Input
Motor
+ ー
Hydraulic circuit drawing
Air bleeding valve
Relief valveCartridge grease
M
Solenoid
PDI discharge port Rc 1/8
Series progressive system port Rc 1/8
4EGM 10T C
200mℓ400mℓ700mℓ
247
Cartridge
228 25
127
104
176
5925
109
4-φ9 Installation hole
Air bleeding valve
PDI Discharge port Rc1/8
Series progressive valve port Rc1/8
400
109
25
2559
(127) 176104 13
4-φ9 Installation hole
Air bleeding valve
PDI Discharge port Rc1/8Series progressive valve port Rc1/8
[EGM-10T-4-2C]
[EGM-10T-4-4C]
[EGM-10T-4-7C]
[EGM-10T-4-4C]
PumpDischarge volume 10mℓ/minDischarge pressure 10MPa (safety valve set pressure)
PowerDC24V
Mortor 20W/0.8APressure relief solenoid 26W/1.1ATotal 46W/1.9A
Pressurization Max. ON time: 7.5 min.Power distribution rate Max.25% (20℃)Working consistency Cartridge Grerase No.000,00,0,1Recommended grease MP0, FS2, MT1Cartridge size 200mℓ, 400mℓ, 700mℓWeight 1.78kg (2C), 1.83kg (4C), 1.8kg (7C)Pressure relief Built-in solenoid
EGM-TDual-function motorized pump
Can operate both PDI and series progressive systems by switching built-in solenoid valve.
Directions for use
• Use recommended greases.• Never use molybdenum disulfide-contained grease• Use lithium greases. (Contact us for consultation when other than
lithium grease is used.)• Do not use any greases containing substances that attack brass and
rubber.• Avoid continuous operation.• When refilling grease in main pipe and during test operation, stick
to an intermittent cycle of running for 30 seconds and resting for 90 seconds. Failure to follow this requirement will result in thermal protector being activated by a heated solenoid, leaving the solenoid de-energized without pressure built up.
MGI metering valve with clogged line detection:P.59
● Related parts
Pressure gauge:P.85
GPL Pressure switch for grease:P.62
Adapter assemblies:P.185
MGLA metering valve with performance monitor:P.61
MG2 metering valve:P.57
MG2C metering valve:P.57
Main tubing:P.171
LUBE original grease:P.81
JVPA junctions:P.58
-
77 78
主配管脱圧作動型
定量バルブ
マルチポート
集中給脂システム
主配管脱圧作動型
定量バルブ
リューベ
オリジナルグリース
配管部品
周辺機器
リューベハイブリッド
集中潤滑システムLHL
Compatible with Both PDI and
Series Progressive Metering Valve
System for Sm
all-Medium
Machine
MGI metering valve with clogged line detection:P.59
● Related parts
Pressure gauge:P.85
GPL Pressure switch for grease:P.62
Adapter assemblies:P.185
MGLA metering valve with performance monitor:P.61
MG2 metering valve:P.57
MG2C metering valve:P.57
Main tubing:P.171
LUBE original grease:P.81
JVPA junctions:P.58
PumpDischarge volume 10mℓ/minDischarge pressure 10MPa (safety valve set pressure)
PowerDC24V
Mortor 20W/0.8APressure relief solenoid 10W/0.4ATotal 30W/1.2A
Working consistency Cartridge Grease No.000,00,0,1Recommended grease MP0, FS2, MT1Cartridge size 200mℓ, 400mℓ, 700mℓWeight 1.8kg (4C), 2.8kg (7C)Pressure relief Built-in solenoid
228
12787
213104
5970
252525
27
φ21
13
(Sticker)
4-φ9 Installation hole
Air bleeding valve
PDI Discharge port Rc1/8Series progressive valve port Rc1/8
Wiring port
Dimensional drawing
[EGME-10T-4-2C]
SpecificationsHOW to order
Wiring diagram
1 2 3 4
DC24V Input
(+) (+)-
Terminal box
SolenoidMotor
4EGME 10T C
200mℓ400mℓ700mℓ
247
Cartridge
228
12787
213104
5970
252525
27
4-φ9 Installation hole
Air bleeding valve
PDI Discharge port Rc1/8Series progressive valve port Rc1/8
Wiring portφ21
13
400
127
87
213104
5970
2525
25
27
φ21
13
4-φ9 Installation hole
Air bleeding valve
PDI Discharge port Rc1/8Series progressive valve port Rc1/8Wiring port
[EGME-10T-4-2C]
[EGME-10T-4-4C]
[EGME-10T-4-7C]
Hydraulic circuit drawing
Air bleeding valve
Relief valveCartridge grease
M
Solenoid
PDI discharge port Rc 1/8
Series progressive system port Rc 1/8
EGME-TDual-function motorized pump
Can operate both PDI and series progressive systems by switching built-in solenoid valve.
Directions for use
• Use recommended greases.• Never use molybdenum disulfide-contained grease• Use lithium greases. (Contact us for consultation when other than
lithium grease is used.)• Do not use any greases containing substances that attack brass and
rubber.• Avoid continuous operation.
-
LUBE Original Grease MP、FS、MT、LFL-H1
LUBE Hybrid Lubricant LHL300、X100
81
82
LUBE Original Grease
LUBE Original GreaseLUBE Hybrid Lubricant
LUBE Hybrid Lubricant
-
81 82
主配管脱圧作動型
定量バルブ
マルチポート
集中給脂システム
主配管脱圧作動型
定量バルブ
リューベ
オリジナルグリース
配管部品
周辺機器
リューベハイブリッド
集中潤滑システムLHL
LUB
E O
riginal Grease
LUB
E H
ybrid
Lubricant
■Next-generation lubricant which contributes environment and human・ Reducing lubricant consumption・ Preventing the deterioration and decomposition of cutting
fluid・ Reducing the abrasion of machine parts
Advantages of Oil Liquidity Excellent transport property No solidification
+Advantages of Grease High Load-carry capacity Wear
resistance Excellent oil film Maintenance property Adherent property
Integrating the advantages of Oil and Grease
・ Excellent load-carrying capacity and wear resistance The excellent load-carrying capacity and wear resistance prevent seizures and excessive wear.
・ Excellent water resistance and corrosion residence LHL is versatile to emulsification and softening even when water is introduced. In addition, its excellent
corrosion resistance prevents the development of rust.
・ Excellent migration property Developed as lubricants for centralized lubrication systems, LHL has excellent transport property and
supplying LHL in a right amount at a right time guarantees ideal lubrication effects.
FS[High performance grease for heavy load carrying capacity]Excellent heavy load carrying capacity, wear resistance, shear stabitity, heat resistance,oxidation stability, water resistance and rust preventive property.
LFL-H1[High-performance grease for food, medical and cosmetic machines]LFL-H1 has acquired NSF H1 certification. It is a grease agent suitable for the environment and conditions in which food, medical and cosmetic machines are used. It has excellent pumpability and intervention to components. In order to improve safety and simplify its use, it comes in cartridges. LFL-H1 is also suitable for concentric supply.
Model Part Number CapacityLFL-H1-4 249301 400mℓ
Color of Grease : beige
Model
Model
LUBE Original Grease
MP[High class all-around grease of Lithium systems]Excellent shear stability heat resistance, oxidation stability, water resistance, rust preventive and load carrying capacity
Integrating the advantages of Oil and Grease
●Comparison of bearing life test results
Ordinary Lithium based EP2
FS2
250 4,800 Hour
Test conditions(ASTM D 1741B)Temperature:125℃ Bearing:#6306 Revolution:3,500rpm Load:Thrust-178N, Radial-111N
White
400mℓ 700mℓ
White
Model
BlueGreen
orange
200mℓ 400mℓ 700mℓ
Model
400mℓ 700mℓ
Black
[LHL300]
NSF registration number: 140284
Green
LUBE Hybrid Lubricant
LHL
=
Model Part Number Capacity consistencyMP0-4(1) 249050 400mℓ
0MP0-7(1) 249060 700mℓ
Color of Grease : Brown
Model Part Number Capacity ColorLHL300-4S 249113 400mℓ
yellowLHL300-7 249112
700mℓLHL X100 249137 Brown
Model Part Number CapacityFS2-2 249069 200mℓFS2-4 249053 400mℓFS2-7 249063 700mℓ
Color of Grease : Brown
LHL-X100 Performance Test Data
1000
100
10
0.001 0.010 0.100 1.000
Typical Properties of LHL-X100
Appearance Color Worked Penetration Copper Corrosion (100 deg. C / 24h) Oil Separation (100 deg. C / 24h) w.t.% ThickenerBase Oil Viscosity(mm2/sec)Base Oil Viscosity Index
LHL-X100Semi-fluid
Brown460
* PassN/AUrea11412.297
* No change in color into green or black on copper plate is observed.
40 deg. C100 deg. C
Test Items
Thickness of Oil Film (LHL-X100・Lithium-based Grease・Oil)
Rolling speed(m/s)
LHL-X100 Special Urea Grease provides thicker oil films in slow rolling speed range.Having tested the performance of lubricants by focusing on thickness of oil film provided by each lubricant, we found that the oil films become thinnest when rolling speeds become 0m/s( oralmost 0m/s). Both greases provide thicker oil films than oil. LHL-X100, however, (a special urea grease)provides even thicker oil films than lithium grease. The test results prove that LHL-X100 prevents oil film deficiencies more effectively and efficiently.
Fretting Resistance Test Utilizing the ASTM F4170 Fafnir Test
LHL-X100 LiNo.2
1.2
1.0
0.8
0.6
0.4
0.2
0.0
Load
RollingMotion
Outline Sketch of Fafnir test equipment
Fafnir Test Results
Thickness of Oil Film
(nm)
LHL-X100 Urea-base
Li #000 Lithium
Oil #110
Testing MethodIn conformity with ASTM D 4170 Fafnir Test[Testing Conditions]Shaft : ANDREWS W 5/8Weight : 2450N (Ball 9pcs, Surface Pressure : 1.9GPa)Rolling Angle : 12º (Rolling Width : Approx. 3.0mm)Rolling Cycle : 3.4Hz(Approx. 200 cycles)Time Duration : 10hTemperature : Room temperatureWarm-up Operation : NoAmount of lubricant applied : 1.0 + 0.05g per bearing ? 0.2 + 0.01g[Evaluation Method]Amount of abrasion : Measuring the decrease in the mass of each race.
-
Pressure gauge
Hand grease gun
Grease vacuum cleaner
Pressure gaugeGrease filler pump Pneumatic pump for pail, Hand grease gunGrease vacuum cleanerProximity sensor for Series Progressive Valve
85
86
87
88
Accessories
-
85 86
主配管脱圧作動型
定量バルブ
マルチポート
集中給脂システム
主配管脱圧作動型
定量バルブ
リューベ
オリジナルグリース
配管部品
周辺機器
リューベハイブリッド
集中潤滑システムLHL
Accessories
Model Part NumberP3-C JC0005
Model Part NumberLG-400 252422
Discharge volume 540mℓ/minDischarge pressure 34.3MPaWorking air pressure 0.4~0.7MPaAir consumption 315ℓ/min(ANA)Grease capacity 16kgPumpWeight 6kg
Discharge volume 1.2mℓ/StrokeMaximum pressure 40MPaGrease capacity 400gWeight 1.4kg
Pressure gauge
Pressure gauges with reference pointer for visual mounting
Specifications Model
Dimensional drawing
MPa0
2
4
10
φ52
45
10
9.5R1/8
(29.5)
6
8
14
109146-5
MPa0
5
10
25
φ52
45
10
9.5R1/8
(29.5)
15
20
14[PB100]
φ5 G1/4
φ70.6
(33)
13
57
16
3
(6.5)
MPa0
10
20
50
30
40
[GV50-G]
[PB250]
18
7
38
25
21
35.5
2-φ3.5
2-φ6.28.4 1.6
109102-5
[PP]Pressure gauge fitting plate
[PB100] [PB250] [GV50-G]
Grease filler pump
Pneumatic pump for pail
Hand Grease gun
Model
SpecificationsDimensional drawing
110
24
310298
62
208
555
170
80
340±5
363±5
φ62.7
φ10φ14.5
120
175±5
Grease can be filled in pneumatically.
Dimensional drawing
Model
Specifications
※ Caster is optional
Accuracy ±3% F.STemperature range 15℃ ~ 40℃
MaterialBurdon pipe C6872T (over10MPa C5191T) Housing SPCCHousing SPCC
Model Part Number Pressure range (MPa) ThreadPB100 109146 10
R1/8PB250 109147 25GV50-G 209139 50 G1/4GV50-R 500649 50 R1/4
Model Part NumberPP 109102
Pressure gauge
Pressure gauge fitting plate
Directions for use
• Use care not to drop or exert other strong impact.• Do not apply pressure beyond specified range.
-
87 88
主配管脱圧作動型
定量バルブ
マルチポート
集中給脂システム
主配管脱圧作動型
定量バルブ
リューベ
オリジナルグリース
配管部品
周辺機器
リューベハイブリッド
集中潤滑システムLHL
Accessories
E2E-X2E1 E2F-X2E1 E2F-X2Y1Power voltage DC10~24V AC24~240VWorking voltage dimension DC10~40V DC10~30V AC20~264V
Output Form DC 3 leads NPN AC 2 leadsDetecting Distance 2mm±10%
Setting Distance 0~1.6mmDetecting Object Iron12×1mm
Protection class IEC Standards IP67 IEC Standards IP68
Grease vacuum cleaner
Vacuums excess grease, driven by air. Compact portable model available.Reduces consumption of workshop rags.
Standard set model: GCP Specifications
Model
Proximity sensor for Series Progressive valve
Electrically detects the movement of the indicator pin of progressive valve.Proximity sensor monitors the movement of the indicator pin and detects a system or valve failure.
φ2117
4 10
3338
2-clamping nut
9
M12Toothed washer
Indicator
Dimensional drawingModel
● Items contained in standard set1. Silent filter2. Air Valve (To turn the Vaccum ON/OFF)3. Air Inlet Push-to-connect Coupler4. Vacuum Hose 2m5. Nozzle6. 3 liter Plastic Tank
1
2
34
5
6
Model Part Number Height * Width WeightGCP GC5002 350×160mm 1.8kg
Model Part NumberE2E-X2E1 733225E2F-X2E1 730797E2F-X2Y1 730721