Revision Imaging Procedure 3 Dr Mohamed El Safwany, MD.
-
Upload
arlene-joseph -
Category
Documents
-
view
216 -
download
0
Transcript of Revision Imaging Procedure 3 Dr Mohamed El Safwany, MD.
![Page 1: Revision Imaging Procedure 3 Dr Mohamed El Safwany, MD.](https://reader034.fdocuments.us/reader034/viewer/2022051622/5697c0311a28abf838cdb173/html5/thumbnails/1.jpg)
Revision Imaging Procedure 3
Dr Mohamed El Safwany, MD
![Page 2: Revision Imaging Procedure 3 Dr Mohamed El Safwany, MD.](https://reader034.fdocuments.us/reader034/viewer/2022051622/5697c0311a28abf838cdb173/html5/thumbnails/2.jpg)
SCANNER
GANTRY
TABLE/COUCH
![Page 3: Revision Imaging Procedure 3 Dr Mohamed El Safwany, MD.](https://reader034.fdocuments.us/reader034/viewer/2022051622/5697c0311a28abf838cdb173/html5/thumbnails/3.jpg)
DFOV – DISPLAYED FIELD OF VIEW
• SIZE DISPLAYED ON THE MONITOR
![Page 4: Revision Imaging Procedure 3 Dr Mohamed El Safwany, MD.](https://reader034.fdocuments.us/reader034/viewer/2022051622/5697c0311a28abf838cdb173/html5/thumbnails/4.jpg)
PIXEL SIZE
PIXEL SIZE= DFOV (mm)/ MATRIX SIZE
![Page 5: Revision Imaging Procedure 3 Dr Mohamed El Safwany, MD.](https://reader034.fdocuments.us/reader034/viewer/2022051622/5697c0311a28abf838cdb173/html5/thumbnails/5.jpg)
PIXEL vs VOXEL
PIXEL VOXEL
![Page 6: Revision Imaging Procedure 3 Dr Mohamed El Safwany, MD.](https://reader034.fdocuments.us/reader034/viewer/2022051622/5697c0311a28abf838cdb173/html5/thumbnails/6.jpg)
VOXEL SIZE DEPENDS
• FOV• MATRIX SIZE• SLICE THICKNESS
![Page 7: Revision Imaging Procedure 3 Dr Mohamed El Safwany, MD.](https://reader034.fdocuments.us/reader034/viewer/2022051622/5697c0311a28abf838cdb173/html5/thumbnails/7.jpg)
SCANNING
![Page 8: Revision Imaging Procedure 3 Dr Mohamed El Safwany, MD.](https://reader034.fdocuments.us/reader034/viewer/2022051622/5697c0311a28abf838cdb173/html5/thumbnails/8.jpg)
TECHNIQUE
• kVp
• mA
• TIME
• SLICE THICKNESS
• SLICE INCREMENTATION
![Page 9: Revision Imaging Procedure 3 Dr Mohamed El Safwany, MD.](https://reader034.fdocuments.us/reader034/viewer/2022051622/5697c0311a28abf838cdb173/html5/thumbnails/9.jpg)
Operation consoleGantry and Table
Computed tomography
![Page 10: Revision Imaging Procedure 3 Dr Mohamed El Safwany, MD.](https://reader034.fdocuments.us/reader034/viewer/2022051622/5697c0311a28abf838cdb173/html5/thumbnails/10.jpg)
Before the Procedure
• explain the procedure to the patient.
• If the procedure involves the use of contrast dye, consent should be signed form the patient.
• Ask the patient if he has ever had a reaction to any contrast media.
• Generally, there is no fasting requirement prior to a CT scan, unless a contrast media is to be used. (abdomen and pelvis need fasting and cleaning the colon – iv contrast need fasting 4 hours before the examination).
![Page 11: Revision Imaging Procedure 3 Dr Mohamed El Safwany, MD.](https://reader034.fdocuments.us/reader034/viewer/2022051622/5697c0311a28abf838cdb173/html5/thumbnails/11.jpg)
CT Scan of the Brain
• An imaging technique of the brain that reveal tumors, blood clots, hemorrhages, or other abnormal anatomy. A series of computerized images of the brain at various levels are taken to reveal normal anatomy or any abnormality.
![Page 12: Revision Imaging Procedure 3 Dr Mohamed El Safwany, MD.](https://reader034.fdocuments.us/reader034/viewer/2022051622/5697c0311a28abf838cdb173/html5/thumbnails/12.jpg)
Computed tomography
![Page 13: Revision Imaging Procedure 3 Dr Mohamed El Safwany, MD.](https://reader034.fdocuments.us/reader034/viewer/2022051622/5697c0311a28abf838cdb173/html5/thumbnails/13.jpg)
HOUNSFIELD UNITS
• Numeric information in each pixel of ct image
• Related to composition & nature of tissue
• Represent the density of tissue
• Also called as CT NUMBER
![Page 14: Revision Imaging Procedure 3 Dr Mohamed El Safwany, MD.](https://reader034.fdocuments.us/reader034/viewer/2022051622/5697c0311a28abf838cdb173/html5/thumbnails/14.jpg)
air --- 1000
fat ---70
Pure water 0
Csf +8
White matter +30
Gray matter +45
blood +70
Bone/cacification +1000
![Page 15: Revision Imaging Procedure 3 Dr Mohamed El Safwany, MD.](https://reader034.fdocuments.us/reader034/viewer/2022051622/5697c0311a28abf838cdb173/html5/thumbnails/15.jpg)
CT /MRI
• CT PICTUREI. WHITE MATTER IS
DARKER THAN GREY MATTER SINCE LIPID CONTAINING MATERIAL IS RADIOLUCENT
I. CSF IS BLACK
• MR PICTURE GREY GREY
MATTERMATTERT1WIDARK
T2WI
BRIGHT
WHITE WHITE MATTRMATTR
BRIGHT DARK
CSFCSF GREY TO DARK
WHITE
![Page 16: Revision Imaging Procedure 3 Dr Mohamed El Safwany, MD.](https://reader034.fdocuments.us/reader034/viewer/2022051622/5697c0311a28abf838cdb173/html5/thumbnails/16.jpg)
LOW VENTRICULAR
![Page 17: Revision Imaging Procedure 3 Dr Mohamed El Safwany, MD.](https://reader034.fdocuments.us/reader034/viewer/2022051622/5697c0311a28abf838cdb173/html5/thumbnails/17.jpg)
CT Scan Basics• The denser the object, the whiter it is on CT
– Bone is most dense = + 1000 Hounsfield U.
– Air is the least dense = - 1000H Hounsfield U.
17
![Page 18: Revision Imaging Procedure 3 Dr Mohamed El Safwany, MD.](https://reader034.fdocuments.us/reader034/viewer/2022051622/5697c0311a28abf838cdb173/html5/thumbnails/18.jpg)
CT Scan Basics: Windowing
18
Focuses the spectrum of gray-scale used on a particular image.
![Page 19: Revision Imaging Procedure 3 Dr Mohamed El Safwany, MD.](https://reader034.fdocuments.us/reader034/viewer/2022051622/5697c0311a28abf838cdb173/html5/thumbnails/19.jpg)
CT SINUS CORONAL VIEW
MAXILLARY SINUS
19
NASAL SEPTUM
![Page 20: Revision Imaging Procedure 3 Dr Mohamed El Safwany, MD.](https://reader034.fdocuments.us/reader034/viewer/2022051622/5697c0311a28abf838cdb173/html5/thumbnails/20.jpg)
ANATOMYThe pulmonary arteries carry blood from the heart to the lungs.
They are the only arteries that carry deoxygenated blood.
![Page 21: Revision Imaging Procedure 3 Dr Mohamed El Safwany, MD.](https://reader034.fdocuments.us/reader034/viewer/2022051622/5697c0311a28abf838cdb173/html5/thumbnails/21.jpg)
PATIENT POSITIONING
Proper breath hold instructions should be given
Ensure the patient connected IV lines, are long enough to
allow full travel of the couch without being pulled or entangled
while undergoing a CT
![Page 22: Revision Imaging Procedure 3 Dr Mohamed El Safwany, MD.](https://reader034.fdocuments.us/reader034/viewer/2022051622/5697c0311a28abf838cdb173/html5/thumbnails/22.jpg)
![Page 23: Revision Imaging Procedure 3 Dr Mohamed El Safwany, MD.](https://reader034.fdocuments.us/reader034/viewer/2022051622/5697c0311a28abf838cdb173/html5/thumbnails/23.jpg)
Cervical Spine 3 – Trauma
• • Indications– Trauma
• • Sequences– Sag T1 FSE/TSE– Sag T2 FSE/TSE– Sag IR T2 FSE/TSE– Ax IR T2 FSE/TSE– Ax T2 FSE/TSE
• Can add sag T2 GRE to r/o hemorrhage
![Page 24: Revision Imaging Procedure 3 Dr Mohamed El Safwany, MD.](https://reader034.fdocuments.us/reader034/viewer/2022051622/5697c0311a28abf838cdb173/html5/thumbnails/24.jpg)
![Page 25: Revision Imaging Procedure 3 Dr Mohamed El Safwany, MD.](https://reader034.fdocuments.us/reader034/viewer/2022051622/5697c0311a28abf838cdb173/html5/thumbnails/25.jpg)
![Page 26: Revision Imaging Procedure 3 Dr Mohamed El Safwany, MD.](https://reader034.fdocuments.us/reader034/viewer/2022051622/5697c0311a28abf838cdb173/html5/thumbnails/26.jpg)
Diffusion gradients sensitize MR Image to Diffusion gradients sensitize MR Image to motion of water moleculesmotion of water molecules
More motion = Darker image More motion = Darker image
Freely Diffusing Water = DarkFreely Diffusing Water = Dark Restricted Diffusion = BrightRestricted Diffusion = Bright
- Diffusion contrast -
![Page 27: Revision Imaging Procedure 3 Dr Mohamed El Safwany, MD.](https://reader034.fdocuments.us/reader034/viewer/2022051622/5697c0311a28abf838cdb173/html5/thumbnails/27.jpg)
27
- Principles -Isotropic and Anisotropic diffusion• Diffusion is a three dimensional process, but
molecular mobility may not be the same in all directions
• In brain white matter, diffusion’s value depends on the orientation of the myelin fiber tracts and on the gradient direction*
![Page 28: Revision Imaging Procedure 3 Dr Mohamed El Safwany, MD.](https://reader034.fdocuments.us/reader034/viewer/2022051622/5697c0311a28abf838cdb173/html5/thumbnails/28.jpg)
28
Perfusion imagingPerfusion imaging
• DefinitionsDefinitions
• PrinciplesPrinciples
• Some more definitionsSome more definitions
• Perfusion techniquePerfusion technique
• ApplicationsApplications
• FutureFuture
![Page 29: Revision Imaging Procedure 3 Dr Mohamed El Safwany, MD.](https://reader034.fdocuments.us/reader034/viewer/2022051622/5697c0311a28abf838cdb173/html5/thumbnails/29.jpg)
29
DefinitionsDefinitions
• Perfusion is refer to the delivery of oxygen Perfusion is refer to the delivery of oxygen and nutrients to the cells via capillaries and nutrients to the cells via capillaries
• Perfusion is identified with blood flowPerfusion is identified with blood flow which is measured in milliliters per minute which is measured in milliliters per minute per 100 g of tissue per 100 g of tissue
![Page 30: Revision Imaging Procedure 3 Dr Mohamed El Safwany, MD.](https://reader034.fdocuments.us/reader034/viewer/2022051622/5697c0311a28abf838cdb173/html5/thumbnails/30.jpg)
• Good Luck