Retrospective Comparison of 3177 Eyes Implanted with Presbyopic IOLs
Carlos Buznego MDElizabeth A. Davis MD, FACS Guy M. Kezirian MD, FACS
William B. Trattler MD
Dr. Buznego is a consultant to Alcon, Allergan, Glaukos, Inspire, Ista, QLTI
Purpose
• Compare visual outcomes following cataract surgery with presbyopic IOLs at distance, intermediate and near– Tecnis Aspheric Multifocal +4 Add– Crystalens Accomodating HD– Restor Aspheric Multifocal +3 Add
SurgiVision® DataLink IOL Edition: Comparison
• IOL Results Registry: – Data not collected using a protocol, but reported
by surgeons into a registry – Administered by SurgiVision® Consultants, Inc.– Funded by Bausch + Lomb,
Methods: Data Filters
• Eyes evaluated: Best case scenario– No prior surgery– “Average” measurements • Mean K’s 41.00 – 46.50 • Axial length range 22 – 26.5 mm • Preop corneal astigmatism ≤ 1.00 D
– Postop results screened for best results • Postop spheroequivalent ± 0.50 D • Postop astigmatism ≤ 0.75 D
Methods: Analysis
• Used last reported postop exam in the 1-3 month interval
• Analysis based on Snellen visual acuities alone• Analysis does not consider visual quality: – Contrast– Glare
Results: IOL Counts
0500
10001500200025003000 2641
391 145
UCVA Distance: Mean Acuities
10
20
30
40
50
25.1 25.8 25.5
UCV
A (
20/X
)
p Not Significant
UCVA Intermediate: Mean Acuities
10
20
30
40
50
24.1
29.5
24.2
UCV
A (
20/X
)
HD v. Tecnis p Not SignificantEither HD/Tecnis v. ReSTOR p <0.05
UCVA Near: Mean Acuities
10
20
30
40
50
34.1
23.218.9U
CVA
(20
/X)
HD v. either ReSTOR or Tecnis p <0.01 ReSTOR v. Tecnis p <0.01
UCVA Distance
2020 20/25 20/30 20/400%
20%
40%
60%
80%
100%
Crsytalens HDReSTOR SN6AD1 (Aspheric Plus 3)Tecnis Multifocal (ZM900 and ZMA00)
UCVA Intermediate
2020 20/25 20/30 20/400%
20%
40%
60%
80%
100%
Crsytalens HDReSTOR SN6AD1 (Aspheric Plus 3)Tecnis Multifocal (ZM900 and ZMA00)
UCVA Near
2020 20/25 20/30 20/400%
20%
40%
60%
80%
100%
Crsytalens HDReSTOR SN6AD1 (Aspheric Plus 3)Tecnis Multifocal (ZM900 and ZMA00)
Results
• At distance, all lenses were equivalent.• At intermediate, Crystalens and Tecnis
Multifocal were statiscally better than Restor• At near, Tecnis was better than Restor which
was better than Crystalens
Comments and Conclusion
• Some sampling bias may be present • N different for each lens• Tecnis eyes contributed by a small number of surgeons
• This analysis does not control for pupil size – Pupil size may affect performance of presby-IOL’s
• Vision quality not evaluated (glare, mesopic visual function, low contrast acuity, etc.)
• Further evaluation is necessary
Thank you.