Resume (1)

3
ANKUR SARKAR Mobile No: 07828060080 Email ID:[email protected] Experience: 3Years in Erection, Testing, Commissioning & operation of Electrical Equipment of Thermal Power Plant. ASSETS AND CAPABILITIES Adaptable to work under pressure. Eager and enthusiastic to learn new things and very consistent and responsible when it comes to work discipline and attitude. Well versed in different industrial equipments involving in power plant industry & equivalent. Ability to work with different levels of people. SYNOPSIS Presently working in SV Power Ltd 70MW TPP; a Unit of ACB India Ltd as . Engineer (Electrical) from Sep-09-2015 to till date. Current Profile:- Re-commissioning of 70MW TPP installed at villege-Renki, Hardibazar, Korba. Successfully synchronization of 63MW generator (Make-Shandong). Commissioning & Charging of 80MVA Generating Transformer & 12MVA UAT. Commissioning & Maintenance of HT (6.6KV) Motor having rated capacity of 1900KW, 1250KW, 750KW, 665KW, 350KW, 275KW. Commissioning & Maintenance of LT (0.4KV) Motor having rated capacity of 175KW, 160KW, 132KW, 110KW to 0.75KW. Commissioning & Maintenance of 32Nos. of HT (6.6KV) Switchgear, Make-ABB VD4. Commissioning & Maintenance of LT (0.4LV) Switchgear; Make-Siemens, C&S, L&T. Commissioning & Maintenance of 1 No. of Station Transformer (20MVA, Make-EMCO), 4 Nos. of Station Service & Unit Service Transformer (2MVA, Make-Voltamp), 9 Nos. of BOP Transformers (1.6MVA, Make-Voltamp). Modification of Chinese based controller Esp to ador corona based controller. PAST EXPERIENCE As a Engineer (Electrical ) in Swastik Power & Mineral Resources Pvt. Ltd. A unit of ACB India Ltd at Kanberi, Korba - Since 13 th September 2013 to 8 th September 2015. 2X25 MW CFBC Boiler (IJT) at Kanberi, Korba Operation of all Electrical Equipment for 25MW TPP; the same is mentioned below. Erection, Testing, Commissioning of 25MW Alternator (Make- TDPS) Siemens 11KV- 1640A-31.25MVA, AVR, Synchronizing Panel, Relay Metering Panel. Testing, Commissioning & setting of GPR Numerical Relay Micom P343 & P141, Synchronizing panel with AUTO/MANUAL/DEAD BUS scheme. Erection, Testing, commissioning & operation of 11KV HT switchgear (ABB), 0.4KV MCCs, 1 no. Station cum Generating Transformer 31.5MVA (Make-Aditya Vidyut) with Control Relay Panel having differential relay ABB SPAD 346C3, Over current & earth fault relay ABB REF615 & Frequency Relay Micom P923; 3 nos. Unit Auxiliary Transformer 2.5MVA (Make-Aditya Vidyut) with over current & earth fault relay Micom P211 (Make-Schneider); 6 Nos. HT Motor (BFP & CWP) having rating 500KW & 400KW with its over current & earth fault relay Micom P111E (Make-Schneider).

Transcript of Resume (1)

Page 1: Resume (1)

ANKUR SARKARMobile No: 07828060080 Email ID:[email protected]: 3Years in Erection, Testing, Commissioning & operation of Electrical Equipment of Thermal Power Plant.

ASSETS AND CAPABILITIES Adaptable to work under pressure. Eager and enthusiastic to learn new things and very consistent and responsible when it comes

to work discipline and attitude. Well versed in different industrial equipments involving in power plant industry & equivalent. Ability to work with different levels of people.

SYNOPSIS Presently working in SV Power Ltd 70MW TPP; a Unit of ACB India Ltd as . Engineer

(Electrical) from Sep-09-2015 to till date.

Current Profile:- Re-commissioning of 70MW TPP installed at villege-Renki, Hardibazar, Korba.

Successfully synchronization of 63MW generator (Make-Shandong). Commissioning & Charging of 80MVA Generating Transformer & 12MVA UAT. Commissioning & Maintenance of HT (6.6KV) Motor having rated capacity of 1900KW, 1250KW,

750KW, 665KW, 350KW, 275KW. Commissioning & Maintenance of LT (0.4KV) Motor having rated capacity of 175KW, 160KW,

132KW, 110KW to 0.75KW. Commissioning & Maintenance of 32Nos. of HT (6.6KV) Switchgear, Make-ABB VD4. Commissioning & Maintenance of LT (0.4LV) Switchgear; Make-Siemens, C&S, L&T. Commissioning & Maintenance of 1 No. of Station Transformer (20MVA, Make-EMCO), 4 Nos. of

Station Service & Unit Service Transformer (2MVA, Make-Voltamp), 9 Nos. of BOP Transformers (1.6MVA, Make-Voltamp).

Modification of Chinese based controller Esp to ador corona based controller.

PAST EXPERIENCE

As a Engineer (Electrical ) in Swastik Power & Mineral Resources Pvt. Ltd. A unit of ACB India Ltd at Kanberi, Korba - Since 13th September 2013 to 8th September 2015.2X25 MW CFBC Boiler (IJT) at Kanberi, Korba Operation of all Electrical Equipment for 25MW TPP; the same is mentioned below.

Erection, Testing, Commissioning of 25MW Alternator (Make- TDPS) Siemens 11KV-1640A-31.25MVA, AVR, Synchronizing Panel, Relay Metering Panel.

Testing, Commissioning & setting of GPR Numerical Relay Micom P343 & P141, Synchronizing panel with AUTO/MANUAL/DEAD BUS scheme.

Erection, Testing, commissioning & operation of 11KV HT switchgear (ABB), 0.4KV MCCs, 1 no. Station cum Generating Transformer 31.5MVA (Make-Aditya Vidyut) with Control Relay Panel having differential relay ABB SPAD 346C3, Over current & earth fault relay ABB REF615 & Frequency Relay Micom P923; 3 nos. Unit Auxiliary Transformer 2.5MVA (Make-Aditya Vidyut) with over current & earth fault relay Micom P211 (Make-Schneider); 6 Nos. HT Motor (BFP & CWP) having rating 500KW & 400KW with its over current & earth fault relay Micom P111E (Make-Schneider).

Taking all commissioning activities for turbine on barring gear & oil flushing of lube oil system for TG Set Make- Siemens.

Testing & commissioning of all motors of Coal Handling Plant with MCC Operation as well as PLC Operation.

Testing, commissioning of electrical part of fire fighting system. Testing, commissioning of 5 field of ESP with 111KV/600mA TR-Set (Make-Ador), TR SET

Control cubical (Make-Ador) with Electronic Controller PERCICON-III, 111 Nos. of Rapper, its operation Micro tapper panel.

Testing, commissioning of Phase segregated HV Busduct (2000A) & LV Busduct (4000A). Testing, commissioning of All control relay panel of 132KV Plant Sub-station with

CT(Make-CG),PT (Make-CG), Isolator (Make-GR Power)& SF6 Breaker (Make-

Page 2: Resume (1)

Areva).Erection, Testing, commissioning of 11Nos. of VFD ACS 800 (Make-ABB) with its auxiliaries motor i.e. PA Fan Motor (350KW), ID Fan Motor (260KW), SA Fan Motor (110KW), WS Blower Motor (75KW) & CT Fan Motor (90KW).

Testing, commissioning of interfacing of the electrical panels with DCS (METSO-MAX DNA) panels.

Testing, commissioning of Plant Battery (Make-Excide) & Battery Charger (Make- Statcon). Testing, commissioning of Grid and Equipment earthing of whole plant. Testing, commissioning of cable trays and cabling of whole plants.

ACHIVEMENTS

Awarded as best worker of the year for the year 2014 by ACBI(L).

ACADEMEIC/ TECHNICAL QUALIFICATION

Academic Qualifications: 12th :- Maths-Computer; Percentage: 53% & 10th:-Percentage: 69%

Professional Qualification: Degree: Bachelor’s in Electrical Engineering, from Rungta(R1) collage of engineering &

tech ,bhilai, CSVTU Bhilai Percentage: 63.54%

TRANING

Godrej & Boyce Mfg. Co. Ltd( Bhilai) : Four Weeks CSEB (Bhilai) : Six Weeks

COMPUTER AWAIRENESS

Languages : Elementary knowledge of C& C++. Software tools : MS-office 7, 10, Window xp, vista, 7,8.

Co-Curricular Activities

Presented a national level paper in Technotron 2012 at CIT Rajnandgaon. Acted as volunteered in the various activities at R.C.E.T. Acted as volunteer in the various campus drive conducted by R.C.E.T. Cleared up 3r d level taekwondo. Represented State on various games like Volleyball, Badminton etc.

PERSONAL DETAILS

Father’s Name : Tapas Sarkar Date of Birth : 27 March 1989 Sex : Male Marital Status : Un-Married Nationality : Indian

Page 3: Resume (1)

Hobbies : Listening Music, Playing Cricket Language Known : English, Hindi Address : Rajiv Vihar, R.K Nagar Chowk, Bilaspur(C.G). Contact No. :+917828060080,+917024217430. Email Id : [email protected]

DECLATATION

I hereby declare that all the above information is correct to the best of my knowledge.Date: Place:

ANKUR SARKAR