Results of Screening and Qualification Testing of COTS ......jajaja.. Calculations yield T jmax ~150...

24
Results of Screening and Results of Screening and Results of Screening and Qualification Testing of COTS Qualification Testing of COTS Qualification Testing of COTS PEMs PEMs PEMs for Space Applications and for Space Applications and for Space Applications and Lessons Learned in 2004 Lessons Learned in 2004 Lessons Learned in 2004 Alexander Teverovsky, Chris Greenwell /QSS Group, Inc., Ashok Sharma /GSFC/NASA, Nick Virmani /SWALES Associates Parts, Packaging, and Assembly Technologies Office, GSFC, Code 562

Transcript of Results of Screening and Qualification Testing of COTS ......jajaja.. Calculations yield T jmax ~150...

Page 1: Results of Screening and Qualification Testing of COTS ......jajaja.. Calculations yield T jmax ~150 oC (“gold standard”?). Æ P max is just a result of reverse calculations. Analysis

Results of Screening and Results of Screening and Results of Screening and Qualification Testing of COTS Qualification Testing of COTS Qualification Testing of COTS

PEMsPEMsPEMs for Space Applications and for Space Applications and for Space Applications and Lessons Learned in 2004Lessons Learned in 2004Lessons Learned in 2004

Alexander Teverovsky, Chris Greenwell /QSS Group, Inc., Ashok Sharma /GSFC/NASA,

Nick Virmani /SWALES Associates Parts, Packaging, and Assembly Technologies Office,

GSFC, Code 562

Page 2: Results of Screening and Qualification Testing of COTS ......jajaja.. Calculations yield T jmax ~150 oC (“gold standard”?). Æ P max is just a result of reverse calculations. Analysis

CMSE’05 2

OutlineOutlineOutline

Statistics of screening and qualification testing results.Mistakes and problems during testing and electrical measurements.What limits temperature of BI testing?Effectiveness of CSAM for screening.HAST problems.Evaluation of wire bonding.Suggested changes in the guidelines EEE-INST-002 for COTS PEMs.

Page 3: Results of Screening and Qualification Testing of COTS ......jajaja.. Calculations yield T jmax ~150 oC (“gold standard”?). Æ P max is just a result of reverse calculations. Analysis

CMSE’05 3

Statistics of ScreeningStatistics of ScreeningStatistics of Screening13 linear and mixed-signal PEMs (> 4400 samples) have been screened using 3T EM and burn-in.9 lots had no failures during initial EM, 3 lots had 1-2 marginal parametric failures.7 lots had no BI failures, 3 lots had 1 to 2 samples with marginal parametric failures (0.4 to 1.6%), and only one lot had 5 (1%) functional failures.Most problems with EM were observed at -40 oC for high precision ADCs and were likely due to moisture condensation.4 out of 7 lots (763 parts total) had CSAM rejects varying from 1.4 to 35%.

Problems/cost of ADC testing increase exponentially with resolution most test labs relax the requirements.The number of CSAM rejects far exceeds BI failures.Are CSAM rejects potential failures?Will delaminations develop after solder reflow and environmental stresses on good samples?

Page 4: Results of Screening and Qualification Testing of COTS ......jajaja.. Calculations yield T jmax ~150 oC (“gold standard”?). Æ P max is just a result of reverse calculations. Analysis

CMSE’05 4

Statistics of Qualification TestingStatistics of Qualification TestingStatistics of Qualification TestingSMT simulation: 6 out of 10 lots had no failures.

1 out of 32 opamps failed gain marginally;1 out of 27 comparators failed due to crack/breakdown in PS metallization runs;8 out of 27 16-bit ADCs failed parametric test marginally.

HAST: 8 out of 10 lots had no failures.6 out of 20 12-bit ADCs had marginal failures at -40 oC;3/15 step down regulators failed due to EOS and corrosion;2/12 16-bit ADC failed parametric test marginally.

HTOL: Only one out of 8 lots had failures.6/16 16-bit ADC failed parametric test marginally.

Temperature Cycling: 5 out of 7 lots had no failures.7/20 12-bit ADC failed parametric test marginally;1/16 16-bit ADC failed parametric test marginally.

Linear devices are sensitive to mechanical stresses and might fail SMT simulation more problems with “green” technology?

Page 5: Results of Screening and Qualification Testing of COTS ......jajaja.. Calculations yield T jmax ~150 oC (“gold standard”?). Æ P max is just a result of reverse calculations. Analysis

CMSE’05 5

Qualification: Testing of Qualification: Testing of Qualification: Testing of Unscreened PartsUnscreened PartsUnscreened Parts

Currently qualification is performed after screeningCurrently qualification is performed after screening

In one of the projects HTOL testing was performed on unscreened parts with interim measurements after 160 hrs.Initial parametric failures were allowed to go through the testing to estimate worst-case degradation.

Life test at 105 oC

50

60

70

80

90

100

init 160 hr 1000 hr

gain

, dB

Life test at 105 oC

0

0.05

0.1

0.15

0.2

init 160 hr 1000 hr

Vlin

e, %

LIMITS

Marginal parametric failures did not degrade further.Qualification testing of COTS PEMs can be performed on unscreened parts.

Page 6: Results of Screening and Qualification Testing of COTS ......jajaja.. Calculations yield T jmax ~150 oC (“gold standard”?). Æ P max is just a result of reverse calculations. Analysis

CMSE’05 6

Test Problems: Human FactorTest Problems: Human FactorTest Problems: Human FactorA wrong set-up was used during BI multiple failures.SMT simulation (preconditioning) was performed before screening potentially destructive stress.A lot, which had BI failures exceeding PDA, was accepted

a problem (wrong BI conditions) was revealed only when one part failed after assembly onto a board.A two-side CSAM was performed instead of top side only

the parts were subjected to excessive handling.DPA was performed on parts from a non-flight lot.DPA was performed not to the existing requirements.For AD/DA converters, different test labs use different testing algorithms and criteria different test results.

Test labs continue making mistakes additional attention from part engineers is required

Page 7: Results of Screening and Qualification Testing of COTS ......jajaja.. Calculations yield T jmax ~150 oC (“gold standard”?). Æ P max is just a result of reverse calculations. Analysis

CMSE’05 7

Test Problems: Data SheetTest Problems: Data SheetTest Problems: Data Sheet

Example 1, 16-bit ADCAn average line regulation was 84 uV/V, which substantially exceed the specified value of 0.76 uV/V .

Example 2, hybrid.Data sheet: Top = Tst = 100 oC. This was an error, and perMfr. Explanation, these temperatures are limited by the encapsulating material: Tst = -65 to +150 oC, Top = -55 to +150 oC (?).

Example 3, RF devices.Tjmax > Tst because Tjmax =Tg?

Vref_FSE correlation at RT. 5.25V

y = 1.9362x + 0.1734

4.95

4.975

5

5.025

5.05

2.47 2.48 2.49 2.5 2.51 2.52Vref, V

FSE,

V

Correlation between full scale error and voltage

reference measurements (dashed lines are the limits)

Example 4, ADC.Inconsistent requirements for FSE and Vref. FSE failure could be eliminated by using external Vref.

Failure?

Data sheets might have mistakes

Page 8: Results of Screening and Qualification Testing of COTS ......jajaja.. Calculations yield T jmax ~150 oC (“gold standard”?). Æ P max is just a result of reverse calculations. Analysis

CMSE’05 8

Test Problem: Fixtures and AccessoriesTest Problem: Fixtures and AccessoriesTest Problem: Fixtures and AccessoriesExample: Testing of High Power DevicesExample: Testing of High Power Devices

Inductance of wires and load resistors create voltage spikesSome wire-wound resistors

have L>10 µH resulting in spikes of >10V and damaging the parts film resistors were used.Two resistors out of ~100

were found to have intermittent contact.Several test sockets failed

after a few insertions a new design was required.

dtdV

RLVSP ×=

At dV=30V, dt=0.1µs,R=100 Ohm, and L=10 µH, VSP > 30V

Missing contact.Intermittent contact.

spike

A poor reliability of test fixtures and accessories might cause damage to the parts during BI/HTOL testing.

Page 9: Results of Screening and Qualification Testing of COTS ......jajaja.. Calculations yield T jmax ~150 oC (“gold standard”?). Æ P max is just a result of reverse calculations. Analysis

CMSE’05 9

BI Conditions UsedBI Conditions UsedBI Conditions UsedPEM Package Top, oC Tjmax, oC BI T, oC/t, hr

16-bit DAC SSOP28 85 150 85/336 step-down regulator PDIP16 85 125 85/336

comparator SOT23-5 85 150 85/336current amplifier SOIC8 125 150 125/168

step-down regulator MSOP 8 85 125 85/336quad opamp 14-TSSOP 125 150 125/168comparator SO-8 85 150 85/16816-bit ADC 36-SSOP 85 125 85/168

quad opamp SO-14 85 150 85/59012-bit ADC 8-uMAX 85 150 85/16812-bit DAC 14-QSOP 85 150 85/168

step-down regulator 5-TO220 85 125 105/168

In most cases Top has been chosen as a BI temperature.A recommended condition: 85oC/590hr is difficult to impose.Is there a risk of exceeding Top and what is the value of reduced-time BI testing?

Additional analysis has

been performed

Page 10: Results of Screening and Qualification Testing of COTS ......jajaja.. Calculations yield T jmax ~150 oC (“gold standard”?). Æ P max is just a result of reverse calculations. Analysis

CMSE’05 10

What Limits Testing Temperature?What Limits Testing Temperature?What Limits Testing Temperature?

Characteristic temperatures for PEMs: Top, Tjmax, Tst, Tg

Manufacturers warn that exceeding Top, Tjmax, and Tstmight affect reliability of the part.

Characteristic temperatures for PEMs: Top, Tjmax, Tst, Tg

Manufacturers warn that exceeding Top, Tjmax, and Tstmight affect reliability of the part.

Often Pmax is used instead of Tjmax. TTTjjj = T= T= Tooo + + + PPPmaxmaxmax///θθθ jajaja.. Calculations yield Tjmax ~150 oC (“gold standard”?). Pmax is just a result of reverse calculations.Analysis of Mfr.’s data and Tg measurements have shown:

7 out of 11 parts had Tg < Tjmax;Temperature of life test performed by manufacturers exceeded Tjmax in 5 out of 13 cases.

The significance of the Tjmax and Tst is not clear.Tg does not limit BI/HTOL temperatures.

Page 11: Results of Screening and Qualification Testing of COTS ......jajaja.. Calculations yield T jmax ~150 oC (“gold standard”?). Æ P max is just a result of reverse calculations. Analysis

CMSE’05 11

Problems of Choosing BI ConditionsProblems of Choosing BI ConditionsProblems of Choosing BI Conditions

Choosing right BI conditions might require additional analysis and testing.Reduced-time burn-in testing is not effective due to the possibility of introducing defects by handling and EM.

BI conditions for military parts (typically 125 oC/160 hrs + bias) were developed and usually performed by manufacturers and have been proven by a long history of testing.The risk of exceeding Top during BI can not be eliminated until Top remains in the absolute maximum ratings section of data sheets or the note under AMR is changed.For old military parts the risk of inducing defects was not that significant as for advanced PEM.

Example. BI for ADC: 85oC/168hr.Test results. Initial EM: 0/3295; BI: 2 parts failed at RT due to mechanical damage and 1 at -40 oC possibly due to testing.

Page 12: Results of Screening and Qualification Testing of COTS ......jajaja.. Calculations yield T jmax ~150 oC (“gold standard”?). Æ P max is just a result of reverse calculations. Analysis

CMSE’05 12

How Manufacturers Can Exceed How Manufacturers Can Exceed How Manufacturers Can Exceed TTTjmaxjmaxjmaxduring Life Testing?during Life Testing?during Life Testing?

Possible answers:I. Tjmax is not what we think it is.II. A margin exists between the real Tjmaxand the data sheet specification.III. Relaxed electrical biasing conditions.

Manufacturers might perform life testing at non-operational conditions. This limits the value of testing for reliability evaluation.

8X board 1 Ohm, FAN OFF/ON

20

40

60

80

100

120

140

1 10 100 1000 10000

time, s

tem

pera

ture

, o C

2.2

2.3

2.4

2.5

2.6

2.7

Vout

, V

FAN OFF FAN ON

Example: power step-down regulator with Tjmax = +125 oC.Experiments have shown that the part can not operate at Tj > 125 oC

Life test conditions used by manufacturer

At these conditions the part does not oscillate and output transistors are not stressed

Ta = 135 oCRL = 10kVFB = 14.5V

?

Page 13: Results of Screening and Qualification Testing of COTS ......jajaja.. Calculations yield T jmax ~150 oC (“gold standard”?). Æ P max is just a result of reverse calculations. Analysis

CMSE’05 13

Does Low Does Low Does Low TgTgTg Indicate Poor Thermal Indicate Poor Thermal Indicate Poor Thermal Stability?Stability?Stability?

TGA for MC with different Tg TGA measurements showed that materials with Tg ~135 oC had better thermal stability compared to MC with Tg~173 oC.A green MC with a low Tgof ~115 oC was most thermally stable.

90

92

94

96

98

100

300 400 500 600temperature, oC

wei

ght,

%

170 C138 C173 C174 C133 CTg~173 oC

Tg~135 oC

In general, Tg, is not an indicator of thermal stability of molding compounds.Low-Tg MCs are not inferior compared to high-Tg.

DTGA at 1 oC/min N2

-0.08

-0.07

-0.06

-0.05

-0.04

-0.03

-0.02

-0.01

0

250 300 350 400

temperature, oC

mas

s lo

ss ra

te, %

/min

Tg=169

green 115

Tg=146

Tg=165

Page 14: Results of Screening and Qualification Testing of COTS ......jajaja.. Calculations yield T jmax ~150 oC (“gold standard”?). Æ P max is just a result of reverse calculations. Analysis

CMSE’05 14

CCC---SAM Examination: TSSOPSAM Examination: TSSOPSAM Examination: TSSOP---14 14 14 ---style Packagesstyle Packagesstyle Packages

Screening: no electrical failures in 245 parts; however, 105 devices failed CSAM examination.Testing: 20 worst-case CSAM rejects were subjected to HAST and 300 TC from -65 to +150 oC. No failures.

Screening: no electrical failures in 245 parts; however, 105 devices failed CSAM examination.Testing: 20 worst-case CSAM rejects were subjected to HAST and 300 TC from -65 to +150 oC. No failures.

0

20

40

60

80

100

init

after

BIaft

er 30

0 TCaft

er SMT+

HASTaft

er SMT+

Life

dela

min

atio

n, % paddle

leads

Evolution of delaminations

AfterBI

AfterSMT and TC

After SMT and

HAST

Delaminations are changing after ES and SMT simulation CSAM as a screening procedure is not effective.Delaminations at paddle and secondary wire bonds did not cause failures.

Page 15: Results of Screening and Qualification Testing of COTS ......jajaja.. Calculations yield T jmax ~150 oC (“gold standard”?). Æ P max is just a result of reverse calculations. Analysis

CMSE’05 15

CCC---SAM Examination: SSOPSAM Examination: SSOPSAM Examination: SSOP---36 36 36 ---style Packagesstyle Packagesstyle Packages

Screening: no delaminations in 123 devices observed during CSAM examination.Qualification testing: most parts had paddle and finger-tip delaminations after SMT simulation.

Screening: no delaminations in 123 devices observed during CSAM examination.Qualification testing: most parts had paddle and finger-tip delaminations after SMT simulation.

Screening After HASTAfter HTOL and TC

w/o SMTw/o SMT

Delaminations are mostly introduced during SMT simulation CSAM is not effective as a screening procedure.

Page 16: Results of Screening and Qualification Testing of COTS ......jajaja.. Calculations yield T jmax ~150 oC (“gold standard”?). Æ P max is just a result of reverse calculations. Analysis

CMSE’05 16

CCC---SAM Examination: SOTSAM Examination: SOTSAM Examination: SOT---223 223 223 ---style Packagesstyle Packagesstyle Packages

CSAM failures during screening: 15/79; after HAST: 14/14.No electrical failures during screening and qualification.CSAM failures during screening: 15/79; after HAST: 14/14.No electrical failures during screening and qualification.

0

0.5

1

1.5

2

2.5

init SMT220

100 TC 300 TC 1000TC

VO

S, m

V

HAST SCAM failures DC0018screening CSAM failures DC 0018Uscreened DC0020

Delaminations at secondary WB To evaluate the risk

related to delaminations, three groups of parts were

subjected to preconditioning per

JESD22-A113 and 1000 TC from -55 to 125 oC.

To evaluate the risk related to delaminations,

three groups of parts were subjected to

preconditioning per JESD22-A113 and 1000 TC from -55 to 125 oC.

Effect of TC on VOS

No failures and/or substantial parametric changes during testing

Delaminations at Au/Ag bonds are commondefects in PEMs. Secondary bonds are strong enoughto provide reliable connection even in thepresence of delaminations.

delamination

Page 17: Results of Screening and Qualification Testing of COTS ......jajaja.. Calculations yield T jmax ~150 oC (“gold standard”?). Æ P max is just a result of reverse calculations. Analysis

CMSE’05 17

CCC---SAM Examination: TO220SAM Examination: TO220SAM Examination: TO220---style style style PackagesPackagesPackages

CSAM for screening was optional based on results of qualification testingCSAM for screening was optional based on results of qualification testing

Evolution of CSAM images: effect of TC on paddle-MC delaminations

Proportion of delaminationsafter different stress testing

0

10

20

30

40

50

60

init soldering 200 TC 175C/100hrs HAST

dela

min

atio

n, %

Paddle

Die

Leads

No delaminations in the most critical, top-of-die areas.Delaminations at paddle and leads (at secondary WB) increase after environmental stress testing.No failures during reliability testing of delaminated samples.There is no need for using CSAM as a screening procedure.

Page 18: Results of Screening and Qualification Testing of COTS ......jajaja.. Calculations yield T jmax ~150 oC (“gold standard”?). Æ P max is just a result of reverse calculations. Analysis

CMSE’05 18

FollowFollowFollow---up Investigation: Moistureup Investigation: Moistureup Investigation: Moisture---Induced Charge Instability in Induced Charge Instability in Induced Charge Instability in HEXFETsHEXFETsHEXFETs

Analysis of HEXFET failures after HAST showed that the failures were due to moisture-induced charge instability [IMAPS’04].

Analysis of HEXFET failures after HAST showed that the failures were due to moisture-induced charge instability [IMAPS’04].

Water molecules and ions can penetrate to the gate oxide through cracks and pores in Al metallization and SiO2 layers..Nitride passivation is a prime barrier against moisture and ionic contaminations.

Page 19: Results of Screening and Qualification Testing of COTS ......jajaja.. Calculations yield T jmax ~150 oC (“gold standard”?). Æ P max is just a result of reverse calculations. Analysis

CMSE’05 19

FollowFollowFollow---up Investigation: up Investigation: up Investigation: Flux Flux Flux Application During PreconditioningApplication During PreconditioningApplication During Preconditioning

A variety of fluxes used for preconditioning makes them an uncontrollable source of contamination and might cause poor reproducibility of HAST.Water-soluble fluxes applied per JESD22-A113D are the most aggressive fluxes and might contain large quantity of contaminations.Activated fluxes are much more aggressive than RMAs, which are typically used for high-reliability applications.

EDS of three fluxes

0

200

400

600

0 1 2 3 4 5

Energy, keV

inte

nsity

, a.u

.

KESTER 186-18

solder f lux

KESTER 2331-ZX

EDS of three fluxes

0

200

400

600

0 1 2 3 4 5

Energy, keV

inte

nsity

, a.u

.

KESTER 186-18

solder f lux

KESTER 2331-ZXCl

JEDEC Requirements for Preconditioning and Reproducibility of HAST

Preconditioning per JESD22-A113D regarding flux application is inadequate to hi-rel parts assembly conditions and might result in failures, which would never occur in real applications.

Page 20: Results of Screening and Qualification Testing of COTS ......jajaja.. Calculations yield T jmax ~150 oC (“gold standard”?). Æ P max is just a result of reverse calculations. Analysis

CMSE’05 20

FollowFollowFollow---up Investigation: HAST up Investigation: HAST up Investigation: HAST Failures in Failures in Failures in OpampsOpampsOpamps

ArrheniusArrhenius--WeibullWeibull model.model.Biased HAST.Biased HAST.

A relatively low Ea (Peck-Hallbergmodel Ea ~ 0.79 -1.1 eV) increases the probability of failures at low T

0

20

40

60

80

100

0 200 400 600time, hr

failu

res,

%

after 150C/85%/130hr after 130C/85%/350hr after 110C/85%/800hr

Failures during RT testing followed unbiased HAST

Post-HAST testing at RT under bias causes failures similar to

biased HASTA combination of unbiased HAST with RT bias testing might

be a good alternative to biased HAST for QA of parts intended for space applications.

Analysis of HAST failures in opamps showed that unbiased HAST might not reveal failures observed during biased HAST [16th M&A COTS 2004].

Analysis of HAST failures in opamps showed that unbiased HAST might not reveal failures observed during biased HAST [16th M&A COTS 2004].

No failures during

unbiased HAST even

at 150oC/85%

No failures during

unbiased HAST even

at 150oC/85%

Page 21: Results of Screening and Qualification Testing of COTS ......jajaja.. Calculations yield T jmax ~150 oC (“gold standard”?). Æ P max is just a result of reverse calculations. Analysis

CMSE’05 21

Wire Bond ProblemsWire Bond ProblemsWire Bond ProblemsPoor quality bonds might pass initial wire pull test.Degradation and failures in such WBs might happen with time even at relatively benign storage conditions.

Poor quality bonds might pass initial wire pull test.Degradation and failures in such WBs might happen with time even at relatively benign storage conditions.Ex1. Hybrid in plastic package

Missing Al WB to Au plated die

Ex2. ASICsin plastic

QFP

S-containing contamination

Substantial portion of reliability issues are now at the packaging level.How to evaluate quality and reliability of wire bonds in PEMs?

Page 22: Results of Screening and Qualification Testing of COTS ......jajaja.. Calculations yield T jmax ~150 oC (“gold standard”?). Æ P max is just a result of reverse calculations. Analysis

CMSE’05 22

Evaluation of WB QualityEvaluation of WB QualityEvaluation of WB Quality

100.00 10000.001000.000.10

0.50

1.00

5.00

10.00

50.00

90.00

99.00

0.10

time, hr

cum

ulat

ive

prob

abilit

y, %

infant mortality failure

HTSL at 190 deg.C99% confidence bounds

Examples of WB failures after HAST

A technique for WB reliability evaluation is currently under development at the GSFC PA Lab.This technique is non-destructive and does not require full electrical characterization of the part.

Weibull distribution of WB Rc failures during storage at 190 oC

Page 23: Results of Screening and Qualification Testing of COTS ......jajaja.. Calculations yield T jmax ~150 oC (“gold standard”?). Æ P max is just a result of reverse calculations. Analysis

CMSE’05 23

Suggestions for Changes in PEM Suggestions for Changes in PEM Suggestions for Changes in PEM GuidelinesGuidelinesGuidelines

GeneralReinforce engineering control over planning and implementation of S&Q to avoid mistakes.ScreeningMake CSAM examinations optional based on results obtained during qualification testing. Remove warning about Tg as a limiting factor during burn-in testing.QualificationAllow qualification testing of non-screened devices, provided larger quantity is used and interim measurements are performed during life testing to simulate BI conditions.Replace unbiased HAST with a moisture-resistance test, MRT, (a combination of unbiased HAST and biased testing).

Page 24: Results of Screening and Qualification Testing of COTS ......jajaja.. Calculations yield T jmax ~150 oC (“gold standard”?). Æ P max is just a result of reverse calculations. Analysis

CMSE’05 24

Suggestions for Changes in PEM Suggestions for Changes in PEM Suggestions for Changes in PEM Guidelines (cont.)Guidelines (cont.)Guidelines (cont.)

Qualification, (cont.)Eliminate flux application during preconditioning per JEDEC standard JESD22-A113-B. Add environmental contamination testing: MRT after SMT simulation followed by application of a specified activated flux.In cases when DPA indicates problems with intermetallicformation at wire bonds (even when wire pull results are acceptable), perform a wire bond qualification testing. DPAThe proportion of area where intermetallics at Au/Al wire bond are formed should be evaluated. A 50 % criteria for bond area with intermetallic formed might be used to discriminate adequate and poor quality wire bonds.