12thermogh.com/results/JVS Results 04-17-2012.pdfGearbox : Make : Reintjes Type : WAF 1542 Reduction...
-
Upload
truonghanh -
Category
Documents
-
view
217 -
download
1
Transcript of 12thermogh.com/results/JVS Results 04-17-2012.pdfGearbox : Make : Reintjes Type : WAF 1542 Reduction...
JVS Scheeps- en Industrietechniek B.V. 2
Type of vessel : Pushboat Name of the vessel : VEERHAVEN IX Subject : Shaft output measurements Ordered by : ThyssenKrupp Veerhaven B.V. P.O. box 185 3230 AD Brielle The Netherlands Measuring date : April 17th 2011 Ordernr. JVS : 12.0215
Papendrecht, April 19th 2012
Signature : C. Florijn
Approved by : A.J. van Roij
JVS Scheeps- en Industrietechniek B.V. 3
Contents PAGE
1. INSTALLATION PARTICULARS (PORTSIDE ONLY) 4
2. INTRODUCTION 5
3. MEASURING METHOD 5
4. SUMMARY MEASURING RESULTS 6
5. SUMMARY MEASURING EQUIPMENT 7
6. TABLES & GRAPHS Real time graphs of engine rpm and shaft output 8
JVS Scheeps- en Industrietechniek B.V. 4
1. Installation particulars (portside only) Engine: Make : MAK Type : 8M20 Output : 1320 kW @ 900 rpm Flexible coupling : Make : Vulkan Gearbox : Make : Reintjes Type : WAF 1542 Reduction ratio : 3.16 : 1 Serial number : 51859 Propeller shaft: Diameter : 165 mm Shaft material : C45
JVS Scheeps- en Industrietechniek B.V. 5
2. Introduction JVS Scheeps- en Industrietechniek B.V. had been ordered by ThyssenKrupp Veerhaven B.V. to perform shaft output measurements at the portside propulsion installation of the pushboat “VEERHAVEN IX” This investigation is done in corporation with SGS(emission measurements) and GEO the manufacturer of the hydrogen injecting unit. Following measurements has been conducted :
- measurements with hydrogen injection the charging air The shaft output is used as a parameter to compare the emissions for the measured condition.
3. Measuring method The transmitted shaft torque had been measured with strain gauges which were glued on the propeller shaft. With a frequency modulated system the signal is wirelessly transmitted. After demodulation the signal is proportional to the torque. The rpm has been measured with an infra red pick-up system. The shaft output is calculated from the shaft torque and rpm.
JVS Scheeps- en Industrietechniek B.V. 6
4. Summary measuring results In following table the average shaft outputs for the different runs are presented and compared with the measurements performed May 4th 2011.
Run Load in %
May 4 th 2011 Base line
Revs / Output
May 4 th 2011 Hydrogen
Revs / Output
April 17 th 2012 Hydrogen
Revs / Output 1 2 3 4
100 75 50 25
905 822 720 577
1119 847 578 278
901 820 722 573
1084 827 579 281
902 819 720 578
1167 886 618 333
JVS Scheeps- en Industrietechniek B.V. 7
5.Summary measuring equipment Torque measurement : • Telemetry transmission system • Strain gauges Micro Measurements RPM measurement : • RPM infra red pick-up system by JVS Registration : • The measuring signals concerning the shaft outputs have been recorded as a
function of time on a laptop equipped with JVS data-acquisition software.