Residential Ventilation Brochure.pdf
Transcript of Residential Ventilation Brochure.pdf
Fans | Air Handling Units | Chillers & AC | Air Distribution Products | Fire Safety | Air Curtains and Heating Products
Residential Ventilation SystemsSaveVent Comfort - intelligent ventilation solutions by Systemair
2 | Discover the secret of fresh air!
Discover the secret of fresh air!
Since 1974 Systemair cares for the purity of an essential resource. Today Systemair is one of the leading ventilationcompanies worldwide. A success story, which started in Skinnskatteberg, Sweden, with the invention of the inline duct fan. This invention revolutionised the ventilation world.
2 | Discover the secret of fresh air
Discover the secret of fresh air! | 3
Since then, the company has been constantly developed and provides nowadays a complete product range for ventilation technology that sets standards. Whether it is a ventilation concept of a shopping mall, a controlled domestic room ventilation system of a single-family house or the ventilation of tunnels and metro stations - Systemairs’ experts know the requirements and exactly what is needed. More than 2500 employees in more than 60 subsidiaries and 40 countries provide the required customer focus.
We invite you to discover the world of ventilation technology in this brochure together with us. Our Residential Systems Team at Oxford are ready to answer all questions concerning the ventilation subject.
Discover the secret of fresh air | 3
Contents
Discover the secret of fresh air! 2
Systemair worldwide 4
Supply your customers with energy from the earth 18
Make household chores fun again 19
Efficient exhaust ventilation systems 20
Energy efficient EC fans 24
Fan Accessories 30
EC-Vent Controls 35
Domestic / Commercial fans 40
High efficient heat recovery systems 46
Functional Principle Heat Recovery 58
Overview Residential Ventilation Units 50
Systemair Duct Systems 82
SystemairFlex+ „The NEW semi-rigid ducting“ 84
Circular ducts, galvanized 91
Flat ducts, Plastic & metal flat oval 94
ISO+ ducts 101
Silencers 102
Fresh and exhaust air grilles 104
Diffusers 106
Self regulating extract air valves 110
Self regulating fresh air valves 113
Air volume controllers / Fire Dampers 115
GEO Geothermal heat exchanger unit 118
Central Vacuum Systems 120
Combi Whole House „Genius“ unit 122
Systemair worldwide
Skinnskatteberg, Sweden: Systemair AB, the Systemair group head office is in Skinnskatteberg, Sweden. The production is virtually fully automated with modern machinery featuring advanced computer support. Also located here is the company's most advanced test installation for measuring technical data.
Windischbuch, Germany: Production facility for fans and modular air handling units, specialized on engineered products (e.g. tunnel and jet fans). Distribution center.
Hässleholm, Sweden: VEAB is the leading European manufacturer of elec-tric duct heaters. Production of heating and cooling coils, electric and water based.
Ukmerge, Lithuania :Production of smaller air handling units with energy recovery systems.
Maribor, Slovenia: Specialized in centrifugal smoke extract fans, EN certified.
Hasselager, Denmark: Production of modular air handling units.
Bratislava, Slovakia: The factory in Bratislava manufactures air distri-bution products and EN certified fire and smoke dampers.
4 | Systemair worldwide
Save energy, lower running cost!Our label "Green Ventilation" features products with a high energy saving potential.All products labelled with "Green Ventilation" combine energy economy with energy efficiency.
Quality:Systemair is certified in accordance with ISO 9001; ISO 14001 and ATEX. Our research and development laboratories are one of the most modern in Europe; measurements are made in accordance with interna-tional standards like AMCA and ISO.
Kuala Lumpur, Malaysia
Skinnskatteberg, Sweden Hässleholm, Sweden
Ukmerge, Lithuania
Bratislava, Slovakia Maribor, Slovenia
Windischbuch, Germany
Madrid, Spain
Hasselager, Denmark
Kansas City, USA
Dal, Eidsvoll, Norway
Bouctouche, Canada
Kuala Lumpur, Malaysia :Manufacturing of products for the Asian market.
Madrid, Spain: Production of air handling units.
Dal, Eidsvoll, Norway: Production of air handling units for the Norwegian market.
New Delhi, India: The factories in New Delhi and Noida manufacture grilles and diffusers. Systemair Software is also based here.
Bouctouche, Canada: Our main North American production facility of air handling units and inline fans for commercial and residential applications is located in Bouctouche.
Kansas City, USA: Production of fans for the US market.
Milan, Italy: Our factory in Italy, Systemair AC, develops and manufactures a wide range of chillers.
New Delhi, India
Hyderabad, India
Milano, Italy
Langenfeld, Germany
Systemair worldwide | 5
Take a deep breath and enjoy the pure, fresh air of your surroundings. With each breath, you unwind a little bit more and begin to feel fully at ease. You’ve finally arrived.
Make the dream of modern living a reality with intelligent concepts from Systemair - Villavent, increasing living quality which in turn helps to save energy and the environment
Transform your home into a day-spa of fresh filtered air.
Quality of life starts with the climate Residential ventilation by Systemair
Those wishing to build or carry out renovations today are faced with a challenge. The current building regulations demands better insulated and air-tight buildings in order to protect our resources and the environment. Air-tight well insulated buildings prevent natural ventilation through the buildings component parts, which could result in the forma-tion of mould through damp stagnant stale air, which is det-rimental to both the building structure and the health of the occupants. The solution is The SaveVent Comfort -controlled room ventilation by Systemair.
Room ventilation of the highest standardFor over 35 years now, we here at Systemair have been making energy efficient clean air a reality. Be that in large shopping centres, hospitals or simply in the confines of your home. With SaveVent Comfort, we offer you a system which lets you enjoy fresh air around the clock, without having to lift a finger. This is because the air exchange occurs automati-cally and, importantly, is regulated. Opening the windows for a quick airing-out is no longer necessary. Not only is this
8 |
very convenient, you also save both money and energy in the process. Why? Because the heating energy stays where it’s supposed to: in the house. This is especially the case with heat recovery. In this process, the waste air is extracted and used for tempering the cool fresh air, unsightly trickle ventilators, causing draughts, become a thing of the past.
One of life’s luxuriesAlong with used stale air, SaveVent Comfort also expels exces-sive air moisture. This way, you can enjoy a pleasant environ-ment without condensation and mould being eliminated. Not only does this protect the basic fabric of the building, it protects the occupants’ health as well. Just as beneficial to their well-being are our high-quality pollen and dust filters. Even people with allergies can now breathe a sigh of relief with the seal of approval from the British Allergy Foundation. This is how your controlled room ventilation works:The extract fan within the ventilation system extracts air from the wet rooms (kitchen, bathroom, WC) on an continual basis. Depending on the system, a heat exchanger extracts the heat
Principle
| 9
from waste air first. At the same time, fresh air from outside is taken in and filtered.
If necessary, the heat exchanger pre-tempers the cool outside air using the waste air. The fresh air then flows through the vents into the rooms. From there, the supply air flows to the living areas via the landing and hallway and into the kitchen bathroom and WC. This way, the two different air streams don’t mix. The result being an optimum room environment.
Principle
Creating a good atmosphere is a matter of trust SaveVent Comfort
A room’s climate is not a constant, instead it depends on a number of factors, for example, room moisture, CO2 satura-tion, the size of the room as well as the number of people in the room and how long they stay there. All these factors are taken into account with a correctly sized Systemair ventila-tion system. A system which is perfectly tailored to your clients’ needs and buildings, regardless of whether it’s a new build or renovation work. In short: a system like SaveVent Comfort.
Optimum planningIn close collaboration with you, we plan your personal room ventilation options. Based on our calculations and our decades of experience, we put together the SaveVent Comfort system components for you. Of course, we take into account the specific wishes of your clients when doing so, perhaps they want a ventilation system with geothermal heat-ex-changer for example (see p. 20). So what does it all mean? It means you can guarantee complete satisfaction at all times.
10 |
Intelligent room ventilationSensors determine the exact degree of ventilation necessary according to building usage. Subsequently, the intensity of ventilation is monitored effectively, that is, the rotation of the fan is adjusted to meet the requirements necessary at any specific time. This means that the system isn’t always running at full speed. Similarly, preheating the fresh air is only done when needed. This way, your energy costs can be considerably reduced. And since the control mechanism responds without delay, the occupants can enjoy a balanced and healthy, energy efficient indoor environment 24/7. Intelligent technology you can trust from Systemair.
Raising quality of life –Reducing heating costs!
Modern living needs the proper living spaceventilation: SaveVent Comfort
4000
6000
8000
10000
2000
0WärmerückgewinnungAbluftanlageFensterlüftung
kWh/Jahr
168 m Wohnfläche2 10 kWh = 1 Liter HEL oder 1 m Erdgas3
Quelle: Hessisches Ministerium für Wirtschaft, Verkehr und Landesentwicklung
83 %
100 %
42 %
4000
6000
8000
10000
2000
0System with heat recovery
Exhaust systemVentilationthrough windows
kWh/year
168 m living area2 10 kWh = 1 litre fuel oil or 1 m natural gas3
Source: Hessian Ministry of Economics and Transport, Germany
83 %
100 %
42 %
Solution
Systemair runs a special design office for room ventilation systems. These planners are well-trained especially for ventilation in rooms and are able to plan and to offer the most suitable ventilation system for you.
We use the planning software Plancal:Plancal-Nova is a stand-alone drawing software for HVAC. It requires no other CAD applications and is widely used in the HVAC sector.
Plancal-Nova can import and modify drawings from other architecture or drawing software and export them again. Plans can be read and created in 2D as well as in 3D.
Visualisation methods of projects:2D for ground plans or 3D models with or without building. Unclear details can be displayed as sections or 3D details. 3D models offer different perspective views or allow you to take a virtual tour through a building.
CAD planning for ventilation systems
Systemair data setSystemair has created a data set for this software with some specific features: Plancal Nova uses components of the Systemair room ventilation product range and allows calculating the planned system by using the determined air volume with regard to pressure losses of the unit up to the outlets. The determined operation point helps calculating the data of the unit, such as power consumption and sound emission. Plancal Nova can also calculate noise reduction of the duct system from the unit up to the outlets. Therefore, noise problems can be detected early and prevented during the planning phase.
After planning, a suitable bill of materials with Systemair article numbers can be generated to make a detailed offer. The CAD plans can also be used to release installation plans with specified information concerning duct installation inclusive legends and identification marking in colours. This considerably facilitates the installation. This planning documentation ensures an easy inspection because the duct installation can be quickly reproduced.
Important flow information of the system will be automatically listed on printouts.
This wide planning service is currently unique and guarantees safety from tender phase to commissioning.
12 | PlanCal Nova
Perfectly in tune with your customersThe SaveVent Comfort Systems
14 |
Without heat recovery
With heat recovery
SaveVent BasicEfficient exhaustventilation systemwith manual airflow control
In the basic model, the used indoor air is sucked out. Fresh air flows in through the external wall vents. As such, continuous ventilation of the entire home is assured.
SaveVent Basic +Efficient ventilationsystem withintelligent control
Ventilating rooms is even easier with the EC vent. This intelligent control unit can regulate ventilation according to the current CO2 satu-ration, room temperature, humidity and the number of people in the room. Using these parameters it determines the necessity for ventila-tion and regulates the volume of air. All of it is done automatically.
SaveVent Comfort RHighly efficient ventilation with rotary wheel heat exchanger
Your customers want maximum convenience with minimum heat loss? Then recommend them our rotational heat exchanger system. This extracts the heat from the waste air and pre-tempers the cool fresh air. Some of the humidity of the air is also recovered and transferred to the supply air. High-quality fine particle filters make sure the air stays pure.
SaveVent Comfort CHighly efficient ventilation with counter flowheat exchanger
With a reverse flow heat exchanger your customers can achieve the highest degree of heat recovery. The system automatically switches between normal mode with heat re-covery and summer mode without it. In Summer a bypass function overrides the heat recovery.
Components
With SaveVent Comfort, you are able to enjoy continuous fresh air in the home. Even with our basic configuration, you can enjoy the best climate conditions.
The benefits: tailored aeration and ventilation
energy-saving low operating costs simple installation user-friendly quiet-running long life
The benefits: controlled aeration and ventilation as
needed intelligent control energy-saving, low operating costs easy installation quiet-running long life user-friendly menu navigation day/night operation set by timer
The benefits: controlled aeration and ventilation heat recovery degree of up to 85% Summer bypass function extreme energy savings
quiet-running allergy-friendly humidity recovery, thus consistently pleasant indoor climate
The benefits: controlled aeration and ventilation heat recovery degree of up to 90% bypass function automatic de-icing function extreme energy savings quiet-running user-friendly optional fine particle filter
For whichever convenient ven-tilation system your customers choose and regardless of their structural circumstances, with our ductwork systems you rise to every challenge.
Whether from galvanised steel sheeting or polymer, whether round or oval, all pipes are extremely robust, resistant to deformation and, if necessary, easy to clean.
Your clients can make the selec-tion and choose the size to meet their individual requirements. This guarantees the safe and economical distribution of air through the building.
Do your customers prefer modern living? What about classical, maybe elegant or perhaps they prefer the style of the country house? Regardless of which fittings your clients like, they’re bound to find the design they’re looking for in our versatile range of high-quality ceiling and wall vents.
Simply show your customers the models in our catalogues or refer them to our website.www.systemair.co.uk
Systemairduct systemsMultiple optionsavailable
Systemairair distribution productsCeiling or wall mounted.
Comfort which can be improved on even further: with components which automatically manage the supply of fresh air and save on energy too. Could there be such a thing as too much convenience?
Components | 15
Something you can Trust Your “all-round worry-free package” from Systemair
For whichever configuration level you choose, in SaveVent Comfort you are getting room ventilation of the highest qual-ity. This is because we place the greatest emphasis on qual-ity, functionality, efficiency and energy conservation when developing our products. And since we only want to offer you the absolute best, we put our innovations through their paces before they reach you. Our Research and Development Centre in Sweden is one of Europe’s most state-of-the-art test labora-tories for ventilation technology.
Expert advice from the startIt goes without saying that such a high-quality system also comes with high-quality service. As such, we make ourselves available to you with our helpful advice during the planning and tendering process. Using the building plans we determine your required air quantity. The basis for this are the current building regulations. We then plan your entire ventilation system using our experience and the latest CAD programmes. This way, you can be sure that your system and all of its com-ponents are optimally coordinated with the building. We also make it easy for you to put together an offer: This enables us to provide you with a straightforward offer for the supply of all necessary materials, installation and commissioning (as ap-propriate). This “One-Stop-Shop” enables you to have peace of mind that any grey areas that would otherwise occur between the supply, installation and commissioning are taken care of by the same organisation. Provided the system is constructed
Service | 17
according to plan, we will of course offer a warranty for its proper functioning. We also take great care to ensure that our products are delivered quickly and are easy to assemble. This not only simplifies the work for you, it also reduces both the construction time and the costs for your clients, which they will no doubt appreciate. (should you choose to install yourselves).
If necessary, we also help you during the commissioning and adjustment of the system. We can also thereafter provide an annual service of the system. With our filter subscription, for example: You can maintain a healthy room climate and keep energy consumption down. We are happy to automatically deliver new filters for the system on a regular basis. Our all-round worry-free service makes it easy.
Since 1974, Systemair has been making clean air reality. In the mean-time, our company has established itself as one of the global market leaders in the area of ventilation technology. A success story which began in Skinnskatteberg in Sweden and continued rapidly with the invention of the duct fan. Today, we develop ventilation technology which sets new standards. Be it for major projects like shopping cen-tres, tunnels or underground train stations, or for smaller undertak-ings for room ventilation in family homes, our experts know what matters.
Systemair
If you have any difficulties starting up the system or general questions on room ventilation, give us a call! 01993 778481Our technical support hotline is available Mon-Fri from 8:30AM to 5:00 PM. Tel: 01993 772270
Supply your customers with energy from the earthWith Geo, our brine geothermal heat exchanger
Do you want to improve the level of efficiency of your ventila-tion unit? Do you want a pleasant indoor room climate for relaxing on hot summer’s days? Then why not simply use geothermal heating from Systemair. Not only is it available all the time for free, it helps you save on your energy costs too.
The temperature in the earth is practically constant through-out the year. As such, it’s suitable for preheating the cold out-side air in winter with the help of a heat exchanger. Then in summer, the warm air can be cooled down before it reaches your home’s interior. The heat exchanger’s piping needs to be buried at a depth of 1.5 to 2 meters. This is the only way to ensure that a large enough temperature gradient occurs. Since we only want to provide your customers with the best in this area too, we have developed “Geo”. With this geothermal heat exchanger,
the heat or coolness of the earth first passes into the brine (wa-ter with antifreeze agent). Only after it has arrived in the base-ment is it transferred to the supply air using a heat exchanger.
The clear advantage with GeoUnlike the air duct geothermal heat exchanger, with Geo the air is not drawn in through underground pipes. Not only is this more hygienic, it does away with the otherwise necessary regular cleaning. On top of that, Geo is better value and more robust than the air duct system. This is because the piping can have much smaller dimensions (Dia 32 instead of Dia 200). This also means that it is easier to install. Furthermore, the brine system is easier to manage. Your customers decide at what outside temperatures Geo should start up. This conserves the supply of geothermal heat and gives you exactly the room climate you want.
The forward-lookingway to use energy:Systemair “Geo”
18 | Supply your customers with energy from the earth
Make household chores fun againVillavent Central Vacuum Cleaner
You will no doubt want to keep up with the times when it comes to household chores too and ensure the greatest con-venience possible. So why not install our Villavent Central Vacuum Cleaner! With this system, all you have to do is insert a suction hose into a socket in the wall and then can get started straight away. No more pulling around a clunky machine behind you, which often likes to get caught on valu-able pieces of furniture, leaving behind ugly marks. And no more need to carry heavy items from floor to floor in order to vacuum clean. Household chores really can be this easy.
Incredible suction. Incredibly quiet.This helps your customers maintain a healthy room climate with clean air. For one, its very strong suction guarantees maximum cleaning of furniture, floor and rugs. For the oth-er, sucked in dirt is sped directly into the vacuum cleaner bag of the central device. This can be mounted in a utility room like the basement or garage. This means that the vacuum cleaner is extremely quiet and you don’t have any annoying
background noise in the rooms of your house.
Additionally, the central device blows the waste air directly to the outside. This ensures that dust doesn’t swirl up in your util-ity room - meaning that time is saved when cleaning and those with allergies don’t have to worry. Equipped with a Hepa filter, the vacuum cleaner is even suited to passive houses whose building envelope cannot be cut through by air discharge openings. The long, flexible suction hose comes equipped with a telescopic pipe and floor nozzle. This means your customers can work in ease and give their backs a break. Maintenance of the central vacuum cleaner is generally limited to regular cleaning of the suction casing and replacing the filter bags.as required.
Vacuum-cleaningtoday:Villavent centralvacuum cleaner
Central vacuum cleaner | 19
20 | Exhaust fan unit Systemair Residential Ventilation Systems
Efficient exhaust ventilation systemsfrom SystemairWithout heat recovery
SaveVent Comfort BasicEfficient exhaustventilation systemwith manual airflow control
SaveVent Comfort Basic +Efficient ventilationsystem withintelligent control
Systemairduct systemsExtremely flexible
SaveVent Comfort Basic Basic Basic+ Basic+
Application Single family house Flat Single family house Flat
System Extract only Extract only Extract only Extract only
Location Roof Space / Loft Roof Roof Space / Loft Roof
Ventilation unit Extract fan: KVKE EC, Controller EC-Vent Extract fan: TFSK Extract fan: KVKE EC;
Controller EC-SaveVentExtract fan: TFSK; Controller EC-SaveVent
Extract valvesin bathroom, toilet and kitchen; products: valves
in bathroom, toilet and kitchen; pro-ducts: valves
in bathroom, toilet and kitchen; products: valves
in bathroom, toilet and kitchen; products: valves
Intake valves Windows and FAV Windows and FAV Windows and FAV Windows and FAV
* ducting with air volume control
Overview SaveVent Comfort applications
Systemair Residential Ventilation Systems Exhaust fan unit | 21
General description
• Exhaust air units are the most cost-efficient method of mechanical ventilation.
• Exhaust air units consume less electrical power because only the fan needs energy.
• However: no heat recovery and no pre-heating of supply air !
FunctionThe used, humid and polluted room air in exhaust air rooms such as kitchens, bathrooms and toilet rooms is exhausted by a venti-lator through a duct system and led via roof or facade to the outside. Fresh air enters living rooms, children‘s rooms and bedrooms via facade inlets (valves with filter in the facade) and ensures continuous aeration of the whole apartment. The controlled room ventilation reduces ventilation heat losses compared to conventional aeration by open windows.
Systemairair distribution productsJust your style
Room Intermittent Extract Continuous ExtractMinimum Rate Minimum High Rate Minimum Low Rate
Kitchen 30l/s adjacent to hob; or 6060l/s elsewhere
13l/sTotal extract rate should be at least the whole dwelling ventilation rate given in Table 5.1b
Utility room 30l/s 8l/sBathroom 15l/s 8l/sSanitary accommodation 6l/s 6l/s
Table 5.1a Extract Ventilation rates
Table 5.1b Whole dwelling Ventilation ratesNumber of bedrooms in dwelling
1 2 3 4 5Whole dwelling ventilation rate a,b (l/s) 13 17 21 25 29
Notes:a. In addition, the minimum ventilation rate should be not less than 0.3l/s per m2 of internal floor area. (This includes all floors, e.g. for a two-storey building add the ground and first floor areas)b. This is based on two occupants in the main bedroom and a single occupant in all other bedrooms. This should be used as the default value. If a greater level of occupancy is expected add 4l/s per occupant.
Building Regulations -Part F Ventilation 2010
22 | Exhaust fan unit Systemair Residential Ventilation Systems
Exhaust air unit in a single-family house
Exhaust air unit in an apartment building, centrally
Advantages for an apartment building
• Low maintenance costs
• Less power consumption - only one fan
Disadvantages for an apartment building
• No heat recovery
• No pre-heating supply air
• Only rough filtration of the fresh air possible
• Fire safety and noise protection measures have to be respected.
Advantages for a single-family house
• Cost-efficient method
• Smaller duct system
Disadvantages for a single-family house
• No heat recovery
• No pre-heating supply air
• Only rough filtration of the fresh air possible
Systemair Residential Ventilation Systems Exhaust fan unit | 23
Conclusion:Exhaust air units meet the requirements according to EnEV (German Energy Savings Act) and DIN 1946-6, but cold supply air from the outside offers less comfort. In addition to this, filtering of the supply air is limited. The main advantages are cost-efficient acquisition costs and installation.
Exhaust air unit in an apartment building, decentrally
Advantages of exhaust air for each apartment
• Individually controllable
• Clear costs
• Exhaust air via facade: no noise protection and fire safety measures to the neighbour necessary
Disadvantages of exhaust air for each apartment
• Facade breakthrough in each apartment
• No heat recovery
• No pre-heating supply air
• Only rough filtration of the fresh air possible
24 | Exhaust fan unit Systemair Residential Ventilation Systems
KVKE EC
The KVKE EC models have a single inlet centrifugal fan with backward-curved blades and a maintenance-free external rotor motor(EC). These fans develop relatively high static pressure and have a very high efficiency. The fans are delivered with a pre-wired potentiometer (0-10V) that allows you to easily find the desired working point.The KVKE motor and impeller are mounted on the access cover for ease of maintenance. The service cover can be easily removed by withdrawing the hinge pin. Motor protection is integrated in the electronics of the motor. The fans can be installed in any position and are easy to connect to spiral ducts using FK mount-ing clamps. The KVKE models are manufactured from galva-nised sheet steel and are thermally and acoustically insulated with a 50 mm layer of rockwool with a surface liner which pre-vents the migration of fibres into the airstream.
KVKE * 125 EC 160 EC 200 EC 250 EC 315 EC
Art no. 2570 2571 2575 2577 2578
Voltage/Frequency V/50 Hz 230 230 230 230 230
Power W 68.7 67.8 156 265 395
Current A 0.536 0.53 1.10 1.64 2.38
Max air flow m3/hr 374 544 864 1156 1865
R.p.m. min-1 3339 2592 3033 2821 2380
Max temp. of transported air °C 60 60 60 55 45
“ when speed controlled °C 60 60 60 55 45
Sound pressure level at 3 m dB(A) 41 39 46 49 50
Weight kg 13.2 17.5 19 28.1 38.8
Insulation class, motor B B B B B
Enclosure class, motor IP 44 IP 44 IP 44 IP 44 IP 44
Motor protection Integral Integral Integral Integral Integral
Speed control Electronic MTP MTP MTP MTP MTP
Technical data
Performance
• EC-motors,highlevelofefficiency• 100%speedcontrollable•Speedregulatorincluded•Lowsoundlevel• Integratedmotorprotection• Potentiometerincludedforeaseofcommissioning
1
2
3
45
12
3 4 5
Exhaust Terminal ConfigerationSpecific Fan Power (W/l/s)
Energy Sav-ing Trust Best Practise Performance compliant
Kitchen +1 Additional wet room 0.25 Yes
Kitchen +2 Additional wet room 0.27 Yes
Kitchen +3 Additional wet room 0.30 Yes
Kitchen +4 Additional wet room 0.35 Yes
Kitchen +5 Additional wet room 0.42 Yes
Kitchen +6 Additional wet room 0.53 Yes
SAP Appendix Q (*KVKE 125 EC Fan)
Systemair Residential Ventilation Systems Exhaust fan unit | 25
What does EC stand for?An EC-Motor = Electronically commutated motor.EC-technology is intelligent technology using integral electronic control to ensure that the motor always runs at optimal load. With ease of control, the speed can be varied to match the airflow demand and operate at much higher efficiencies than that of a standard AC motor - Therefore saving energy & money
D
EG
H 50
F27
C B
47
A
*
*
A B C D E F G HKVKE 125 EC 125 433 479 125 128.5 442 246 470KVKE 160 EC 160 482 528 145.5 132.5 505 266 530KVKE 200 EC 200 482 534 150.5 149 505 303 530KVKE 250 EC 250 578 700 176 174 596 359 620KVKE 315 EC 315 680 802 208.5 207.5 705.5 430 730
Dimensions
FK p. 32
Ventilation accessories
VK p. 34RSK p. 35
IGK p. 33FGR p. 35 IGC p. 34
Fast clamps Back draft damper Gravity louvre shutter
Filter cassette Intake grid Intake grid
Flexible silencer
Electrical accessories
MTP 10 p. 36 EC-Vent p. 37
SCD p. 102
Controller Control board
Add EC-Vent Controls to any EC fan to offer full Demand Control Ventilation - See page 37 for details
26 | Exhaust fan unit Systemair Residential Ventilation Systems
K - EC
K - EC 160 * 200 250 315 M 315 L
Art no. 2580 2581 2583 2584 2585
Voltage/Frequency V/50 Hz 230 230 230 230 230
Power W 74.4 78.6 119 166 340
Current A 0.63 0.63 0.92 1.14 2.08
Max air flow m3/hr 544 774 1033 1415 1732
R.p.m. min-1 3105 2468 2628 2113 2719
Max temp. of transported air °C 60 60 40 40 55
“ when speed controlled °C 60 60 40 40 55
Sound pressure level at 3 m dB(A) 47 51 46 50 57
Weight kg 3 3.8 3.5 7 7
Insulation class, motor B B B B B
Enclosure class, motor IP 44 IP 44 IP 44 IP 44 IP 44
Motor protection Integral Integral Integral Integral V
Speed control Electronic MTP MTP MTP MTP MTP
Technical data
Performance
• EC-motors,highlevelofefficiency• 100%speedcontrollable•Speedregulatorincluded•Lowsoundlevel• Integratedmotorprotection• Potentiometerincludedforeaseofcommissioning
1
2
3
4
5
1 2 3 4 5
The K EC series is designed for installation in ducts. All the K-fans have minimum 25 mm long spigot connections. The fans have backward-curved blades and external rotor motors (EC). The FK mounting clamp facilitates easy installation and removal, and prevents the transfer of vibration to the duct. The fans are delivered with a pre-wired potentiometer(0-10V) that allows you to easily find the desired working point.The potentiometer is set between 6-10V from factory. This can easily be changed if the installation requires more performance. To protect the motor from overheating the fan has integral thermal contacts with electrical reset. The casing is manufactured from galvanised sheet steel with the seams folded to give the fan a close to air tight casing. Outdoor mounting and wet room applications are possible due to the fans air tight casing and the IP 55 rated terminal box with a IP 68 rated M20 cable gland.
Exhaust Terminal ConfigerationSpecific Fan Power (W/l/s)
Energy Sav-ing Trust Best Practise Performance compliant
Kitchen +1 Additional wet room 0.24 Yes
Kitchen +2 Additional wet room 0.27 Yes
Kitchen +3 Additional wet room 0.30 Yes
Kitchen +4 Additional wet room 0.36 Yes
Kitchen +5 Additional wet room 0.43 Yes
Kitchen +6 Additional wet room 0.57 Yes
SAP Appendix Q (*K160 EC Fan)
Systemair Residential Ventilation Systems Exhaust fan unit | 27
Dimensions
Model A B C D E (F)
K160 EC 159 286 25 147 26 198
K200 EC 199 336 30 148 27 205
K250 EC 249 336 30.5 144.5 27 202
K315 M EC 314 408 32.5 160.5 27 220
K315 L EC 314 408 37.5 160.5 27 225
K 200 EC/AC
EC-motors consume an average of 30% less energy than standard AC-motors
In Europe alone, Ventilation fans consume about 197,000GWh
Even a 12-15% increase in efficiency could reduce CO2 emissions by 19 million tons
Its time to use Green Ventilation and do your bit for the environment
40
øA
øAøB
CD
E
(F)
88
FK p. 32
Ventilation accessories
VK p. 34RSK p. 35
IGK p. 33FGR p. 35 IGC p. 34
Fast clamps Back draft damper Gravity louvre shutter
Filter cassette Intake grid Intake grid
Flexible silencer
Electrical accessories
MTP 10 p. 36 EC-Vent p. 37
SCD p. 102
Controller Control board
28 | Exhaust fan unit Systemair Residential Ventilation Systems
TFSK - EC
TFSR / TFSK - EC 160 200
Art no. 1226/1223 1227/1224
Voltage/Frequency V/50 Hz 230 230
Power W 81.5 74.6
Current A 0.64 0.587
Max air flow m3/hr 580 778
R.p.m. min-1 3162 2501
Max temp. of transported air °C 45 45
“ when speed controlled °C 45 45
Sound pressure level at 3 m dB(A) 43 43
Weight kg 4.2/4.6 5.4/6.2
Insulation class, motor B B
Enclosure class, motor IP 44 IP 44
Motor protection Integral Integral
Speed control Electronic MTP 10 MTP 10
Technical data
Performance
• EC-motors,highlevelofefficiency• 100%speedcontrollable•Speedregulatorincluded•Swingoutmotor/impellerforservice• Integratedmotorprotection
The TFSR EC and TFSK EC roof mounted fans are driven by EC motors and intended for use as extract fans in smaller premises such as self contained flats and apartments as well as storage areas, smaller work-rooms etc. The fans are delivered with a pre-wired potentiometer(0-10V) that allows you to easily find the desired working point. The isolation switch is integrated and there are several alternative roof curbs available as accessories. The tilting mechanism simplifies cleaning and maintenance. To protect the motor from motor from overheating, the fans have integrated thermal contact with automatic reset. TFSR EC comes with circular connection whilst the TFSK EC is provided with a square connection. The protection guard prevents un-intentional contact with the impeller.
Systemair Residential Ventilation Systems Exhaust fan unit | 29
FK p. 32
Ventilation accessories
RSK p. 35
Dimensions
Fast clamps Back draft damper Flexible silencer
Electrical accessories
MTP 10 p. 36 EC-Vent p. 37SCD p. 102
Controller Control board
øC
HCøD
A B
øC
c/c Fø9(4x)
E
A B36
TFSK A B øC E sq c/c F
160EC 147 172 334 421 330
200EC 150 187 364 421 330
TFSR A B øC øD HC
160EC 147 172 334 380 205
200EC 150 187 364 439 250
TOB Profiled Roof Plate TOS Flat Roof Plate
30 | Exhaust fan unitAccessories
IGKIntake grid
FGRFilter cassette
FKFast clamp
FKFast clamp
KVKE EC
KVK
LDCSilencer
CB/CBMElectrical heating battery
FKFast clamp
SPIIris damper
Sinus ADiffuser
Sinus BDiffuser
Fast clampsMounting clips which facilitate the installation and removal of fans for service and cleaning. Made from galvanised sheet steel and fit-ted with an 8 mm neoprene lining which suppresses vibration and ensures a tight fit. The mounting clips are clamped together by two screws which allows for connecting ducts with a marginal difference in diameter.
FK Art. no. øD mm100 1607 100125 1608 125150 1609 150160 1610 160200 1611 200250 1612 250315 1613 315
Hanging strap
FKFast clamp
FK
Exhaust fan unit Accessories | 31
Type Art. no. D (mm) L (m)Fequenzy bands [Hz]
63 125 250 500 1000 2000 4000 8000 Tot (dB)
SCD 80 2554 80 1,2 13,6 22,4 40,2 38,7 36,5 41,3 51,6 45,8 39
SCD 100 2555 100 1,2 15,9 22,9 31,1 38,6 36,4 40,6 50,1 35,9 39
SCD 125 2556 125 1,2 11,7 18,9 32,4 29,9 28,8 34,5 40,9 24,5 32
SCD 150 2557 150 1,2 12,2 10,9 29,7 30,1 29 38,3 34,6 20,4 32
SCD 160 2558 160 1,2 19,3 25,4 30,5 27,1 23,8 32,2 27,8 17,3 28
SCD 200 2560 200 1,2 10,7 12,1 28,7 22,8 22,8 30,6 19,4 11,9 26
SCD 250 2561 250 1,2 12,9 18,7 24,3 19,5 19,9 27,7 12,9 10,2 22
SCD 315 2562 315 1,2 16,6 23,2 18 15,2 16,5 19,6 10,1 8,5 17
Noise suppression (dB), Non-woven Isoation 25 mm
(Test Report Nr. A1672-1, Peutzbv)
Flexible silencerThe SCD silencer from Systemair is characterized by high flexi-bility and excellent sound insulation values. The internal duct consists of a closed, non-woven internal hose (washable) and an insulation layer made of glass wool with a thickness of 25 mm and sound reducing and thermal effective properties. The outer casing is made of glass-fibre reinforced, tear-resistant aluminium laminate.The silencer (1 m length) provides duct connections made of galvanized steel sheet on both sides for the connection directly to the duct system. One side is equipped with a connection sleeve and the other side with a connection fitting to guarantee connec-tion flexibility.
Characteristics:Internal hose: non-woven matInsulation: 25 mm glass woolOuter casing: glass-fibre reinforced aluminium laminate Fire classification Bs1 (EN13501-1)
Technical data
material (external) Aluminium
material (internal) non-woven Matte
Temperature range -30 bis +140 °C
Working pressure max. 2000 Pa
Air velocity max. 10 m/s
Length 1,2 m
Connection Sheet steel, galvanized
Intake gridIntake grid for inside or outside installation. Connection diameters ø100-315 mm, and is manufactured from die-cast aluminium and supplied with a wire mesh.
øD = outside diameter ød = connection diameter
IGC Art. no. ød øD100 5581 100 125125 5582 125 150160 5583 160 185200 5584 200 225250 5585 250 275315 5586 315 350
D
d
SCD
IGC
32 | Exhaust fan unitAccessories
VK Art. no. A B C D E F G10 5636 142 15 103 96 5 46 312 5638 164 12 115 117 5 38 415 5605 178 20 130 152 4 50 520 5639 245 20 190 210 5 50 625 5640 299 25 235 260 5 70 530 5641 347 26 274 310 5 70 6
Gravity louvre shutterLouvre shutters for vertical mounting on a wall. The profiled vanes produce a strong upward force which reduces the air resistance. This means that the vanes opens fully at low air velocities as well. All the parts are manufactured in weather-resistant and shockproof nylon material (PVC containing special synthetic). The robust con-struction ensures that the vanes will not become deformed or loose. Above size 45, the vanes are fitted with a cast counterweight. Air velocity should not exceed 12 m/s. The louvre shutters are easy to in-stall. Wall plugs and screws are included above size 15.
ØD
C
A
A
B
F
ØE
Pressure drop
Air velocity in duct m/s
IGK Art.No. øA B100 1630 100 37125 1631 125 37160 1632 160 37200 1633 200 41
Intake gridIntake grid manufactured from galvanised sheet steel with wall flange and wire mesh. Connection sleeve with rubber seal.
265 B 60
275
A
25
3
Wire mesh
Pressure drop
IGK
VK
Exhaust fan unit Accessories | 33
RSK Art. no. øA D B C100 5597 100 80 24 33125 5598 125 100 33 44150 5599 150 100 34 43160 5601 160 120 42 55200 5602 200 140 55 62250 5603 250 140 54 62315 5604 315 140 50 65
Back draft damperBack draft damper for circular ducts, manufactured from galva-nised sheet steel. The two blades are spring-loaded, which means that the damper can also be mounted vertically.
Pressure drop
Filter cassette for circular ductsThe FGR filter cassette is fitted with a standard type G3 panel filter. The cassette housing is manufactured from galvanised sheet steel with rubber-sealed circular connections, toggle locks and disposable filters. Replacement PFR filters are sold in packs of five.The filter cassette is suitable for use as a supply-air filter in indus-trial workshops. The recommended final pressure drop is 170 Pa for the G3 filter.
FGR ø A B C D E100 100 123 199 205 201 190125 125 123 199 205 201 190150 150 123 199 205 201 190160 160 123 199 205 201 190200 200 123 199 302 297 280250 250 123 239 302 297 280315 315 123 239 350 345 330
Filter cassette Art. no. Panel filter (incl. in FGR)
Filter media
FGR 100 1802 PFR 100-160 G3FGR 125 1804 PFR 100-160 G3FGR 150 1807 PFR 100-160 G3FGR 160 1809 PFR 100-160 G3FGR 200 1812 PFR 200 G3FGR 250 1815 PFR 250 G3FGR 315 1818 PFR 315 G3
Free area for filter change
Filter mounting
G3
FGR
RSK
34 | Exhaust fan unitAccessories
ON-OFF service switchREV- Isolator mounted on a bracket, leads connected l max 16 A.
-3POL/03 = 3-pole (closing/auxillary contact 1) lead 3x1.5 mm2 for 1 phase motor TK not lead out.
MTP 10Art-no. 32731Voltage supply V DC 10Control signal kΩ 0...10Working range V 0...10Contact 1 NOSwitching capacity 4A/250VEnclosure class IP 44Weight kg 0.2
ControllerPotentiometer 10kΩ. Combined flush or surface mounting. For the manual control of speed and air flow of electrical fans with 0-10V output. The jetproof IP 54 enclosure is achieved with the included surface mounting case. (Flush-mounting without the surface mounting case, gives a splash proof IP 44 enclosure). NB! EC only.
1 2 3 4 5
+Us -
Us = 0-10V+ = 10V Supply Output signal- = GND
MTP 10
REV
PotentiometerThe EC fans are delivered with a pre-wired potentiometer(0-10V) that allows you to easily find the desired working point.The potentiometer is set between 6-10V from factory. This can easily be changed if the installation requires more performance.
The Potentiometer is fitted inside the fans terminal box
Terminal Cable Description1 Black 1 Tacho output, lsink max 10mA2 Black 2 GND3 Black 3 Control input 0-10 VDC/PWM4 Black 4 Output 10 VDC max 1.1 mA
Exhaust fan unit EC-Vent / Accessories | 35
EC-VentDemand controlled air volume
%CO
2
°C°C
Manually
Hum
idity
Air Q
uality
Presence
Pressure
Temperature
Time Sum
mer/
Winter
EC-Vent controls the degree of ventilation in buildings to meet different levels of occupancy as detected by sensors located within the areas to be ventilated. The result is an indoor climate that always matches building use and occupation. In opposite to
other control systems, all sensors are included for the detection.
Optimal degree of ventilation due to numerous sensors
36 | Exhaust fan unitEC-Vent / Accessories
Wiring EC-Vent
Control board
Room unitA = Power supply
B = Sensor 24V/0..10V, e.g. pressure sensor, CO2 sensor
C = Temperature sensor PT1000
D = Digital sensor 24V, e.g. presence sensor
E = Alarm relay
F = EC fan G = Actuator 24V/0..10V, e.g. 3-way valve
H = Actuator 24V, e.g. spring-return damper motor
I = Analog output 0..10V
J = Modbus
K = Connection EC-Vent RU
EC-Vent: one control - numerous possibilitiesName Article-No.
EC-Vent remote control with integrated temperature and humidity sensor
3018
EC-Vent control box 3115
Room temperature sensor TG-R5/PT1000
Fresh air temperature sensor TG-UH/PT1000
Duct sensor TG-KH/PT1000
5404
35203
202705
Room humidity control /Hygrostat HR1 5150
Time switch 5165
Pressure sensor DSG 200
Pressure sensor DSG 500
Pressure sensor DSG 1000
5169
5170
9466
CO2 Transmitter (digital) CO2RT-R-D
CO2 sensor CO2RT
6993
13704
Presence sensor R24-P 6995
Exhaust fan unit EC-Vent / Accessories | 37
RUArt-no. 3018Voltage V 24Phase DC =Ambient temp. °C 0...50Enclosure class IP 20Weight kg 0.2
Remote Control• Ready for connection to EC-Vent CB
• 2 inputs for CO2, humidity, temperature, presence, pressure sensors etc. 1 input, digital / 0...10V / PT1000 and 1 input, digital / 0...10V
• Built-in humidity and temperature sensors
• User-friendly menu
• Absence mode and boost ventilation function
• 10 m connection wire incl.
EC-Vent Room Unit Wall control unit for EC-Vent CB control device. Blue background illumination of the display, selection knob and 2 buttons.
The EC-Vent control system consists of two units: one central unit CB to be placed near the fan and a display unit RU normally sited in a room easily accessible to the user. These units are connected to each other with a low voltage cable of a max. length of 30 m.
The wall control unit is equipped with a built-in humidity and temperature sensor and 2 inputs for additional sensors.
Control unit Art.No. 3115 - EC-Vent CB control box!
CBArt-no. 3115Voltage V 230Phase ~ 1Frequency Hz 50/60Current A 6Recommended fuse A 10Supply to sensor, 24V DC mA 150Ambient temp. °C -20...50Enclosure class IP 44Weight kg 0.95
Control board• Built-in transformer (230V/24V)
• Control of two fans
• Heating/cooling control, 0..10V
• 3 inputs, digital / 0...10V / PT1000
• 3 outputs, digital / 0...10V
• 1 output EC motor, PWM
• 24V supply voltage for dampers and sensors etc.
The EC Vent is more than a simple control for EC fans. Combined with EC fans, this tool simplifies demand-controlled ventilation making it easy to set up and operate. The unique feature of the EC-Vent is that it provides for a number of control options with up to five sensors (analog or digital). A single parameter such as temperature can be controlled at several different locations. Alternatively, various parameters, (CO2,
humidity, temperature, etc.) can be combined to control the fan directly or as a complement to the weekly schedule and/or the manual control to boost the ventilation if needed. It can also be used to control a heater/cooler or an extra fan via 0-10 V signal.The EC-Vent consists of two units, one central unit to be placed near the fan and a single display unit normally sited in a room easily accessible to the user. These units are connected to each other with a low voltage cable. The EC-Vent allows to connect up to 5 different sensors that simultaneously detect the actual ventilation requirements. In this way, the EC fan will be steplessly controlled to ventilate exactly as much as needed. The result is a good indoor air quality and the user avoids high electricity bills. The central unit for the EC-Vent can be operated stand-alone from the room unit.
EC-Vent room unit RU (Art.No. 3018) is needed for configuration.
EC-Vent control board
TG-R5/PT1000Art-no. 5404Temp. range of adjustment °C 0...50Control signal PT1000Enclosure class IP 30WxHxD mm 86x86x30
Room sensor For measuring room temperature.
TG-R5/PT1000
38 | Exhaust fan unitEC-Vent / Accessories
HR1Art-no. 5150Setpoint %RH 10...95Differential %RH 4% at 45Switching capacity 250V/5AMax. operating temp. °C 40Enclosure class IP 21Weight kg 0.1WxHxD mm 83x136x37
Room humidistatA humidistat for controlling exhaust air fans in response to the relative humid-ity. The humidistat uses human hair as the humidity sensor medium. The set-point can be anywhere between 10 and 95% RH. Base plate in black plastic and cover in white plastic. The HR1 is supplied with a sliding cover over the set-point dial, which can be locked.
The humidistat should be mounted in a location with good air cir-culation and constant temperature and humidity. It should not be fitted on external walls, walls in direct sunlight, corners etc.
The humidistat’s mounting holes make it suitable for fixing on to a terminal box with screws at 60 mm centres.
The humidistat should be precision-calibrated after it has been mounted, and should be recalibrated regularly. Dust and other matter should be removed with a soft brush at regular intervals.
TG-UH/PT1000Art-no. 35203Temperature range °C -40...+60Enclosure class IP 65WxHxD mm 70x93x46
Outdoor sensor For measuring outdoor temperature.
TG-UH/PT1000
TG-KH/PT1000Art-no. 202705Temperature range °C -30 – +70°CTime constant 16 sInsert length mm 60...205Enclosure class IP 65
Duct sensorDuct senor for measuring air temperature in ventilation ducts.
TG-KH/PT1000
HR1
Contacts 1 and 3 close when the air humidity exceeds the preset value.
T 120Voltage V 230Frequency Hz 50Max. current load A 10 (2)Connection time min 0...120WxHxD mm 80x80x25
TimerTimer with 120-minute operating time. Sup-plied with flange for fitting into equipment housing. Casing for surface mounting is availa-ble as an extra. A switch for closing and break-ing circuits. A link can be used to produce a change-over function. The timer makes a quiet ticking sound when connected. This timer is suitable for controlling the REU and RTRDU five step transformers.Frame for wall-
mounting
T 120
Exhaust fan unit EC-Vent / Accessories | 39
Presence detectorA detector that gives a signal when someone is present in the room under supervision. The detector has a pulse detecting function that minimizes the risk for false alarm. Settable output on/off delay. Intended for wall or ceiling mounting.
IR24-P is a presence detector designed for automatic ventilation control of HVAC systems.
IR24-PArt-no. 6559Voltage supply V 24 V AC/DCAmbient temperature °C -20...+50Max. ambient humidity %RH 95Enclosure class IP 40Circuit-breaking relay A NC/NOSwitching capacity 24V DC/0,2ADimensions mm 112x66x45
CO2RT, CO2RT-R-DArt-no. 13704/6993Voltage V 24Frequency Hz 50/60Power consumption W 3Ambient temperature °C -5...+55Re. humidity, non condens. % 90Working range ppm 0...2000Enclosure class IP 30Weight kg 0.1Dimension mm 85x100x30
CO2-sensor for wall mountingCO2RT is a room sensor for measuring carbondioxide, CO2 concentration in indoor environments. Measuring range 0...2000ppm. Output signal 0...10 V for the full measuring range. CO2RT also has a temperature signal, 0...10 V DC for 0...50°C. Apart from the above mentioned temperature signal CO2RT also has a PT1000 temperature sensor with separate terminals CO2RT is intended for wall mounting. The display models (D) have an LCD-display showing both ac-tual values by regularly alternating.
Supply voltage 24 V AC
System neutral 24 V AC
Common
Normally open
Normally closed
1
2
3
4
5
Supply voltage 24 V AC
System neutral 24 V AC
Output 0...10 V (humidity)
Output 0...10 V (temperature)
Output 0...10 V (CO2)
Signal neutral
Output, PT1000-sensor
Output, PT1000-sensor
1
2
3
4
5
6
7
8
CO2RT CO2RT-R-D
DSG 200/500/1000Art-no. 5169/5170/9466Voltage supply V 15V-30V DC/24V~± 15%Outp. 0-10 V, Imax mA 2Enclosure IP 65Current A 0.012Press. range 200 Pa 0...200Press. range 500 Pa 0...500Press. range 1000 Pa 0...1000
Pressure sensorA membrane-type sensor for measuring the differential pressure in non-aggressive gases. The difference in pressure between the sensor’s plus (+) and minus (-) con-
nections affects the membrane, which generates a voltage via a differential transformer. This voltage converts into a continuous DC voltage proportional to the membrane’s position. Cable length approx. 0.5m.
Brown
Output
Pressure connection ø5 mm
Voltage supply15...30V DC24V AC ±15%
Yellow
White
DSG
CO2RT / CO2RT-R-D
IR24-P
40 | Exhaust fan unit Systemair Residential Ventilation Systems
These Axial domestic fans are designed for either wall. ceiling or window* mounting (*kit required) and are ideal for toilets. bathrooms. utility Rooms & kitchens to comply with building regulations on Ventilation. The range includes 100mm. 120mm & 150mm sizes with options for built in sensors to suit all your needs. The units are all manufactured using high ABS thermoplastics for strength and durability. aesthetics and easy cleaning.All products are BEAB approved and carry the CE marking and come com-plete with a 2 year guarantee.
Technical Data
BF100 BF120 BF150
Maximum Airflow l/s 23 l/s 36 l/s 64 l/s
m3/hr 85m3/hr 130m3/hr 230m3/hr
Spigot Size 100mm (4”) 120mm (5”) 150mm (6”)
dBA @ 3m 36 36 35
Voltage 230-1-50 230-1-50 230-1-50
Amps 0.12 0.15 0.15
Fan Options
Ref Code Product Type
BF *** S Axial Fan. Standard model for remote switching (Light switch etc)
BF *** T Axial Fan. Timer model incorporating adjustable timer (1-20 mins)
BF *** TH Axial Fan. Adjustable Humidity control between 40% & 95% RH + Run on timer (1 - 20 mins)
BVK*** Wall Fitting Kit - (External grille. white + wall sleeve)
EGK*** Window Fitting Kit
EFS-PIR Passive Infra Red Sensor with run on timer
*** Fan Size 100. 120 or 150
Dimensions A B C
100 mm 163 98 67
120 mm 182 118 112
150 mm 203 150 72
The Systemair range of domestic in-line fans are designed for duct mounting and are ideal for toilets. bathrooms. shower rooms. utility rooms & kitchens to comply with building regulations on ventilation. The range includes 100mm. 120mm & 150mm sizes. The units are all manufactured using high ABS thermoplastics for strength and dura-bility. All products are BEAB approved and carry the CE marking and come complete with a 2 year guarantee.
Technical Data
IF 100 IF 120 IF150
Maximum Airflow l/s 23 l/s 36 l/s 64 l/s
m3/hr 85m3/hr 130m3/hr 230m3/hr
Spigot Size 100mm (4”) 120mm (5”) 150mm (6”)
dBA @ 3m 32 32 31
Voltage 230-1-50 230-1-50 230-1-50
Amps 0.12 0.15 0.15
Power W 20 25 25
Dimension
IF 100 IF 120 IF 150
øA 100 118 150
B 90 99 110
BF
IF
Systemair Residential Ventilation Systems Exhaust fan unit | 41
The Systemair range of Low-voltage domestic fans are designed for either wall or ceiling mounting and are ideal for shower rooms & bathrooms to comply with building regulations on Ventilation. The range includes 100mm (4”) axial & centrifugal fans with a remote Safety Extra Low Voltage transformer offering integral control options to suit all your needs. The units are all manufactured using high ABSthermoplastics for strength and durability. aesthetics and easy cleaning. All products are BEAB approved and carry the CE marking and come complete with a 2 year guarantee.
Technical Data
EAF 100LV ECF 100LV
Maximum Airflow l/s 23l/s 31l/s
m3/hr 85m3/hr 110m3/hr
Spigot Size 100 mm (4”) 100 mm (4”)
dBA @ 3m 36 39
Voltage 230-1-50 Input
Amps 12 Volt A.C - SELV
Power W 20 20
Ref Code Product Type
EAF 100 LV Low Voltage Axial Fan 100mm to be used with ET Transformer
ECF 100 LV Low Voltage Centrifugal Fan 100mm to be used with ET Transformer
Transformer Part Ref
ET12S Low Voltage Transformer. Standard model for remote switching (Light switch etc)
ET12H Low Voltage Transformer. Adjustable Humidity control between 40% & 95% RH + Run on timer (1 - 20 mins)
ET12T Low Voltage Transformer. Run on timer (1 - 20 mins)
ET12P Low Voltage Transformer. Pullcord
163 67
A 82 mmB 145 mmC 65 mm
EAF LV/ ECF LV
42 | Exhaust fan unit Systemair Residential Ventilation Systems
The Systemair range of domestic centrifugal fans are designed for either wall or ceiling mounting and are ideal for toilets & bathrooms to comply with building regulations on Ventilation. The fan has a 100mm 4” spigot with an integral back draught shutter with options of built in sensors to suit all your needs. The units are all manufactured using high ABS thermoplastics for strength and durability, aesthetics and easy clean-ing. All products are BEAB approved and carry the CE marking and come complete with a 2 year guarantee.
Technical Data
CF
Maximum Airflow l/s 25l/s
m3/hr 90m3/hr
Spigot Size 100mm (4”)
dBA @ 3m 37
Voltage 230-1-50
Amps 0.2
Power W 25
Ref Code Product Type
CF 100 S Centrifugal Fan. Standard model for remote switching (Light switch etc)
CF 100 P Centrifugal Fan. as above but supplied with pullcord switch
CF 100 T Centrifugal Fan. Timer model incorporating adjustable timer (1-20 mins)
CF 100 TH Centrifugal Fan. Adjustable Humidity control between 40% & 95% RH + Run on timer (1 - 20 mins)
BVK100 Wall Fitting Kit - (External grille. white + wall sleeve)
EFS-PIR Passive Infra Red Sensor with run on timer
A B C D E Weight/kg
163 98 Dia 65 90 163 1.1 kg
Technical Data
CBF100
Maximum Airflow l/s 31 l/s
m3/hr 110 m3/hr
Spigot Size 100 mm (4”)
dBA @3m 39
Voltage 230-1-50
Amps 0.27
Power W 45
CBF 100L
Ref Code Product Type
CBF 100 S Centrifugal Fan. Standard model for remote switching (Light switch etc)
CBF 100 P Centrifugal Fan. as above but supplied with pullcord switch
CBF 100 T Centrifugal Fan. Timer model incorporating adjustable timer (1-20 mins)
CBF 100 TH Centrifugal Fan. Adjustable Humidity control between 40% & 95% RH + Run on timer (1 - 20 mins)
BVK100 Wall Fitting Kit - (External grille. white + wall sleeve)
EFS-PIR Passive Infra Red Sensor with run on timer
Dimensions CF100
CBF
CF
Systemair Residential Ventilation Systems Exhaust fan unit | 43
• Speed-controllable• For mounting on external walls• Useful where internal space is limited• Powerful extract performance with low noise
The RVF models are exhaust-air fans for installation on external walls. The unit consists of an impeller with backward-curved blades and a casing in galvanised sheet steel with a white powder-paint coating.All ambient noise created by the fan is kept outside the building if it is installed on an external wall.
Technical Data
RVF 100M RVF 100XL
Maximum Airflow l/s 50l/s 80l/s
m3/hr 200m3/hr 280m3/hr
Spigot Size 100 mm (4”) 100 mm (4”)
dBA @ 10m 26 37
Voltage 230-1-50 Input
Amps 0.16 0.26
Power W 28 60
Speed rpm 2489 2433
Speed Controller REE 1 REE 1
Weight kg 4 5
Max temp of transported air (C) 70 deg C 70 deg C
RVF - External Wall Fan
The Centralised Ducting System (MVS) provides continuous mechanical ventilation throughout the entire house from a single extraction unit and can be used in up to three individual rooms. Made from strong ABS plastic it is very lightweight. making it easy to install in a loft or ceiling void. The fan unit is supplied with three extraction inlets. all 125mm which discharge from one 125mm extract duct through either a wall or roof terminal. Control optionsThe MVS-10 has 14 speed steps, and a standard is set to speed steps 1, 4 and 8 (Low, Normal and Boost respectively). The speed settings for Low, Normal and Boost speeds can quickly be altered by changing the dipswitches under the top cover. The MVS-10 can be controlled by a 3 speed switch or a motor less cooker hood, (F251). The MVS-10R is controlled by the wireless remote speed controller and is also fitted with an induct humidity sensor to automatically increase the speed of the unit when rapid increases in humidity levels occur. The MVS-10 can also be controlled by an external 0-10V signal (not applicable to the MVS-10R).
Technical Data
Model MVS-10DC
Static Pa @ 225m3/hr 400 Pa
Output High 24.4 W
Medium 9.9 W
Low 5.1 W
Max amperage 0.18 amps
Voltage 230-1-50
Weight 3.5kg
Connection diagram for the MVS-10-type EC fans with 3 speeds
m3/ h
Pascal
0 10050 150 200 250 300 350 400 450 500
500
450
400
350
300
250
200
150
100
50
0
= graph number
= power consumption (Watt)
c
X
1
2
3
4
5
6
7
8
9
10
11
12
13
14
66
7
8
9
12
14
20
24
30
40
48
57
65
66
67
8
810
1217
20
2631
40
56
66
73
81
78
68
59
48
35
27
24
17
15
11
9
Mea
sure
d o
n t
he
13 o
f Fe
bru
ary
2007
in t
he
anec
hoi
c ch
amb
er o
f EB
M P
apst
V E N T I L A T I O N S Y S T E M S F O R D O M E S T I C A N D C O M M E R C I A L A P P L I C A T I O N S
Orcon bv Storkstraat 23, 3905 KX Veenendaal, NetherlandsP.o. box 416, 3900 AK Veenendaal, NetherlandsTel. +31 (0)318 54 47 00, Fax +31 (0)318 54 47 06E-mail [email protected], www.orcon.nl
TECHNICAL DATA MVS-10
S p e e d
Step
Airflow
m3/hr
Voltage
V
Pressure
Pa
Motor Data dBA
@ 1mFLC W
1 LOW 85 230-1-50 10 0.06 6 21
3 MIDDLE 127 230-1-50 21 0.07 8 34
6 MIDDLE 200 230-1-50 50 0.12 17 48
7 HIGH 225 230-1-50 65 0.14 20 49
9 HIGH 270 230-1-50 85 0.21 31 52
11 HIGH 320 230-1-50 130 0.40 56 54
14 HIGH 375 230-1-50 175 0.60 81 58
MVS - DC
44 | Multi Extract fan unit Systemair Residential Ventilation Systems
Systemair Residential Ventilation Systems Commercial fan units | 45
Fan Ref Size 6 Size 9 Size 12
Maximum Airflow l/s (m3/hr)
77 (278)
185 (668)
281 (1021)
Sound Power Level dBA@3m
40 53 60
Voltage 230-1-50 230-1-50 230-1-50
Amps 0.24 0.4 0.6
Power W 45 80 120
Controller EAC6 EAC9/12 EAC9/12
Controls. Sensors & Ancillaries
EAC6 Variable speed control (6” only)
EAC9/12 Variable speed control & reversible
EFS-PIR Passive infra red sensor with run on timer
EFS-HS Humidistat
EFS-7DAY 7 day analogue timer
EFS-ROT Run on timer 1-20 mins
EFS-ISO Isolator Switch 3Pole
Performance Graph
Dimensions
Fan Ref A B C D E Hole Dia
ES6W (Wall) 310 310 160-290 278 288 -
ES9W (Wall) 390 390 160-290 361 366 -
ES12W (Wall) 470 470 160-290 440 447 -
ES6P (Panel) 310 310 110 - - -
ES9P (Panel) 390 390 138 - - -
ES12P (Panel) 470 470 154 - - -
ES6G (Window) 205 105 25 - - 184
ES9G (Window) 286 125 25 - - 260
ES12G (Window) 362 145 25 - - 320
The Systemair range of commercial fans are ideal for Offices, Student Accomodations & cleaners cupboards to comply with building regula-tions on Ventilation. The range includes 6”. 9” & 12” models all fully speed controllable. with the 9 & 12” models being reversible for sup-ply & extract air. The fans are complete with thermo-activated shut-ters to prevent draughts and save on costs. Different coloured grilles are available in white. terracotta & brown. standard model is pale grey. The units are all manufactured using high ABS thermoplastics for strength and durability. aesthetics and easy cleaning. The Panel model is designed for refurbishment projects as they will fit most leading commercial wall liners. All products are BEAB approved and carry the CE marking and come complete with a 2 year guarantee.
Panel Fan
Window Fan
ES
Wall Fan
46 | Heat Recovery unit Systemair Residential Ventilation Systems
SaveVent Comfort RLow Energy Thermal Wheel rotational heat exchanger
SaveVent Comfort CLow Energy Counterflow Heat Recovery Units
High efficiency heat recovery systems
Overview SaveVent Comfort applications
SaveVent Comfort C C R
Property Type Single family house / Single flat Muliple Dwellings Single family house / single flat
System Heat Recovery Heat Recovery Heat Recovery
Location Plant Room / Store / Cupboard Plant Room Plant Room / Store /
Cupboard
Ventilation Range SAVE VTC SAVE VTC*, Topvex SC* VR
Extract valves in bathroom, toilet and kitchen; products: valves
in bathroom, toilet and kitchen; products: valves
in bathroom, toilet and kitchen; products: valves
Supply valves In Bedrooms & living room In Bedrooms & living room In Bedrooms & living room
Systemair Residential Ventilation Systems Heat Recovery unit | 47
Systemair duct systemsMultiple options available
General description
• The unit is completely self-controlled and is easy to run by the user
• Heat recovery pre-heats supply air
• Fine filters provide clean and dust-free supply air
• A rotary heat exchanger recovers humidity during winter time
• No temperature fluctuations and cold zones in rooms - even at cold outside temperature
Systemair Air Distribution ProductsJust your style - Wall or Ceiling mounted
FunctionExhausted air from kitchens and bathrooms is ducted via the heat recovery unit to the outside. The unit draws fresh air through a seperate duct system. The heat of the exhaust air is transferred up to 88 % by a heat exchanger to the supply air and returned to living and bedrooms. Within the unit the air is filtered, warmed and dehumidified. Supply & Exhaust ductwork is installed to meet the requirements and restrictions of the building.
Room Intermittent Extract Continuous ExtractMinimum Rate Minimum High Rate Minimum Low Rate
Kitchen 30l/s adjacent to hob; or 6060l/s elsewhere
13l/sTotal extract rate should be at least the whole dwelling ventilation rate given in Table 5.1b
Utility room 30l/s 8l/sBathroom 15l/s 8l/sSanitary accommodation 6l/s 6l/s
Table 5.1a Extract Ventilation rates
Table 5.1b Whole dwelling Ventilation ratesNumber of bedrooms in dwelling
1 2 3 4 5Whole dwelling ventilation rate a,b (l/s) 13 17 21 25 29
Notes:a. In addition, the minimum ventilation rate should be not less than 0.3l/s per m2 of internal floor area. (This includes all floors, e.g. for a two-storey building add the ground and first floor areas)b. This is based on two occupants in the main bedroom and a single occupant in all other bedrooms. This should be used as the default value. If a greater level of occupancy is expected add 4l/s per occupant.
Building Regulations -Part F Ventilation 2010
Advantages & Dis-advantages for different Dwelling types
Advantages for a single-family house
• High heat recovery, thermal comfort
• Less ventilation heat losses
• Humidity regain during winter time with one rotor
• Pre-heating supply air
• Higher energy saving potential
Disadvantages for a single-family house
• Complex duct system
• Higher investment costs
Advantages for an apartment building
• High energy saving potential and less heating is required
• High heat recovery
Disadvantages for an apartment building
• Complex duct system
• Higher investment costs
• Fire safety and sound protection requirements
• Central units: „Heat theft“
Conclusion:A ventilation unit with heat recovery provides a healthy, comfortable indoor enviroment with filtered supply air to the dwelling. Further-more, the energy saving potential meets the future requirements. The decision for a unit with heat recovery allows combining comfort and energy savings.Counterflow heat exchanger vs. rotary heat exchanger: a rotary heat exchanger is the best choice for single-family houses or single resi-dential units. It is more effective and creates a better indoor climate plus thers is no requirement for a condensate drain to overflow. These rotary wheel units also allow for automatic summer by-pass during warmer months. To supply more than one residential unit, a coun-terflow heat exchanger is the right choice.The required energy for frost protection reduces the efficiency of this exchanger.
48 | Heat Recovery unit Systemair Residential Ventilation Systems
Apartment building, decentrally, example for an apartment
Comparison rotating heat and plate heat exchanger
Rotary heat exchangers:
Systemair Residential Ventilation Systems Heat Recovery unit | 49
With these fans, heat as well as humidity can be exchanged. Application for single-family houses or residential units with efficiencies up to 85 %.
Heat exchangingThe wheel structure (similar to corru-
gated board) of the exchanger and continuous rotation between hot and cold air flows heats the exhaust air wheel which trans-fers this heat to the cold supply air in winter time. This effect can be used vice versa in summer time by transferring heat of the outside air to the colder exhaust air. This provides a cooling effect in summer and also leads back the cooling energy of the air conditioning.
Humidity transfer with a condensation rotorThe thermal wheel heat exchanger consists of pure aluminium which transfers humidity exactly when condensate appears on the exhaust air side and is absorbed by the outside air. High tem-perature differences can reach humidity return values up to 60 %. With our rotors, humidity is transferred when needed in winter time. This minimizes dry air.
Counterflow heat exchangers are used to transfer heat and can reach an efficiency of more than 90 %.
Heat exchangingCounterflow heat exchangers lead air flows through parallel plates arranged in a row. On the opposite side supply and exhaust air alternates. Warm air flow
transfers energy via the plate to the cold air flow.
Humidity transfer is not possibleIn winter time, condensate has to be drained into a waste water pipe. The drain should always have either a water trap or running trap to prevent stale odours from coming back up from the drain system.
Separated Air Streams Supply and exhaust air are totally separated from each other to keep the supply air clean.
Counterflow heat exchanger
Frost protectionThe higher the efficiency of an exchanger, the more condensate drops out at high temperature differences. The efficiency also influences the temperature when frost protection is necessary for the exchanger. This concerns outside temperatures when condensate starts freezing. For high quality counter cross-flow heat exchangers with an efficiency of 90 %, this can already begin at -3 °C. In contrast, simple cross-flow heat exchangers with an efficiency of app. 55 %, this does not start until app. -14 °C. The amount of energy necessary for frost protection is correspondingly different. To ensure frost protection and to avoid pulling out energy from the exchanger, outside air can be pre-heated, the supply air can be set back or or the outside air can be bypassed at the heat exchanger via a bypass flap. The missing heat transfer by setting back the supply air fan or during bypass of the supply air has then to be replaced by the heating system.
rotation of the storage mass. Constructive modifications prevent this for units which are /DE marked (transmission 0.1 %).
Rinse chamberSome outside air flow is led on the exhaust air side to produce a rinsing effect. This reduces the transmission of exhaust air to a minimum by carryover. For correct operation of the rinse chamber, a pressure gradient of min. 200 Pa on supply and ex-haust air is necessary.
Frost protectionA condensate drain is not required in residential construction. Furthermore, the rotor does not freeze because of the trans-mission of condensate down to -30 °C by a little exhaust air surplus. A frost protection for heat exchangers is not needed.
Overview Residential Heat Recovery UnitsVR 250 ECH/B VTR 150 VTR 200B VTC Low E VR 300 ECV/B VR 400 DCV/B VR 700 DCV SAVE VSR 300 SAVE VSR 500 SAVE VTC 300 SAVE VTC 700
Application Available with cross flow heat exchangers - VX models
Flats / Apartments
Individual Homes
Multiple Housing / Student Accomodation
Larger Family Homes
SAP Appendix Q Approved
design until living space m² 90 100 140 100 130 220 350 240 400 300 / 250 600 / 560
max. air volume at 120 Pa m³/h 130 236 270 155 210 320 530 336 593 410 / 340 860 / 830
max. sound level at 1m distance dB(A) 47 43 41 47 46 47 51 50 50 45 53
efficiency heat recovery % 85 85 85 86 85 85 80 85 80 80 85
supply air filter - F7 G3 F7 G2 F7 F7 F7 F7 F7 G4 / F7 G4 / F7
extract air filter - G3 G3 G3 G2 G3 G3 G3 G3 G3 G4 / F7 G4 / F7
voltage/frequecy V/50Hz 230 230 230 230 230 230 230 230 230 230 230
max. power fans, each W 59 86 84 26.5 100 115 240 83 169 85 168
electr. Heater W 500 500 or 1000 500 or 1000 N/A 500 or 1000 1670 1670 1670 1670 1700 1700
fuse A 10 10 10 10 10 10 16 10 13 10 13
protection class IP 24 24 24 24 24 24 24 24 24 24 24
weight kg 38 54 46 26 41 56 73 61 72 72 150
duct connections mm 125 125 125 125 125 160 (Bypass 125) 200 160 200 160 250
width mm 1070 600 598 598 598 796 918 1120 1120 762 1170
height mm 265 774 750 579 630 800 800 582 632 802 1214
depth mm 513 467 428 280 326 406 517 461 551 616 860
Isolation of casing mm 20 30 30 10 20 30 30 30 30 30 30
condensate connection (2x) no no no 2 no no no no no no 1/2” 1/2”
page 52 54 56 58 60 62 64 66 68 74 76
50 | Heat Recovery unit Systemair Residential Ventilation Systems
VR 250 ECH/B VTR 150 VTR 200B VTC Low E VR 300 ECV/B VR 400 DCV/B VR 700 DCV SAVE VSR 300 SAVE VSR 500 SAVE VTC 300 SAVE VTC 700
Application Available with cross flow heat exchangers - VX models
Flats / Apartments
Individual Homes
Multiple Housing / Student Accomodation
Larger Family Homes
SAP Appendix Q Approved
design until living space m² 90 100 140 100 130 220 350 240 400 300 / 250 600 / 560
max. air volume at 120 Pa m³/h 130 236 270 155 210 320 530 336 593 410 / 340 860 / 830
max. sound level at 1m distance dB(A) 47 43 41 47 46 47 51 50 50 45 53
efficiency heat recovery % 85 85 85 86 85 85 80 85 80 80 85
supply air filter - F7 G3 F7 G2 F7 F7 F7 F7 F7 G4 / F7 G4 / F7
extract air filter - G3 G3 G3 G2 G3 G3 G3 G3 G3 G4 / F7 G4 / F7
voltage/frequecy V/50Hz 230 230 230 230 230 230 230 230 230 230 230
max. power fans, each W 59 86 84 26.5 100 115 240 83 169 85 168
electr. Heater W 500 500 or 1000 500 or 1000 N/A 500 or 1000 1670 1670 1670 1670 1700 1700
fuse A 10 10 10 10 10 10 16 10 13 10 13
protection class IP 24 24 24 24 24 24 24 24 24 24 24
weight kg 38 54 46 26 41 56 73 61 72 72 150
duct connections mm 125 125 125 125 125 160 (Bypass 125) 200 160 200 160 250
width mm 1070 600 598 598 598 796 918 1120 1120 762 1170
height mm 265 774 750 579 630 800 800 582 632 802 1214
depth mm 513 467 428 280 326 406 517 461 551 616 860
Isolation of casing mm 20 30 30 10 20 30 30 30 30 30 30
condensate connection (2x) no no no 2 no no no no no no 1/2” 1/2”
page 52 54 56 58 60 62 64 66 68 74 76
Systemair Residential Ventilation Systems Heat Recovery unit | 51
VR 250 ECH/B
Voltage/Frequency V/50 Hz 230
Power consumption per fanat operation point W ca. 30
100 m³/h at 80 Pa
SFP kW/m³/sWh/m³
2,110,6
Fuse A 10
Electr. re-heater W 500
Filter, fresh air F 7, bag filter
Filter, extract air G 3, bag filter
Weight / incl. packaging kg 45
Dimension (L x B x H) mm 1071 x 513 x 265
Connection DN 125
• 85 % heat recovery efficiency
• Designed air flow up to about 100 m³/h at 75 Pa (for app. 80 m² living space)
• Humidity recovery: no condensate connection, no frost pro-tection
• For ceiling and wall mounting
• Remote control CE necessary
The housing is insulated with 20 mm PU foam. Top and bottom section can be removed for maintenance. Connection to kitchen hood with an extra connection (DN125) possible.Exhaust air from the hood is bypassed at the rotary heat exchanger, directly to the exhaust air fan. When the hood starts, both fans run at maximum speed. As a result of a considerably lower pressure loss in the kitchen hood duct, the exhaust air fan boosts more air than the supply air fan whereas app. 80 % of exhaust air is led through the hood. Make sure that enough outside air is available during kitchen hood operation.
Surrounding
Mid-frequency band, Hz
LwA dB(A) Tot 63 125 250 500 1k 2k 4k 8k
Supply 67 57 60 60 59 60 57 51 41
Extract 56 42 42 49 53 49 33 24 20
Surrounding 47 31 41 36 41 42 36 33 29
Supply
Exhaust
Optional connection to kitchen hood (type 251-10/B - page 81).
VR 250ECH/B
VR 250ECH/B
Sound dataThe sound data tables indicate the sound power level LwA, which should not be confused with the sound pressure level LpA.
SFP= Specific Fan Power [kW/m3/s]The SFP value stated applies to the complete unit.
Art-no. 12536
52 | Heat Recovery unit Systemair Residential Ventilation Systems
VR 250 ECH/B
F7 Filter fresh airVR Rotating heat recovery unitEF Extract fanSF Supply fanBP Bypass duct ETS Extract air temp. sensorEH Electric heaterG3 Filter extract airSS Supply air temp. sensorOT Overheating thermostatET Emergency thermostatEHS Temp. sensor as rotating controller
1
2
124 195
513
94
64
3
513
77 93147 196
263
131
131
540
5
4
3
4
5
EF
1
2
CGBA D
Ø125
7071
263
290
40 40783HH
1071
Dimension
Duct connections, Ø125 mm:1 Fresh air/outside air2 Exhaust air3 Supply air4 Extract air5 Cooker hood (Bypass)
A Filter, fresh air-/outside air F7B Rotating heat recovery unitC Supply air fanD Reheater battery, electrical heating element, 500 WE Filter, extract G3F Extract air fanG Control circuit board and rotor motor for heat exchanger H Anti-vibration ceiling mounting bracket
Scheme
Accessories
CE p. 80 Timer p. 80CEC p. 80 Wall bracket p. 83TFV p. 80 RCE p. 80
Control panel Cable Timer Timer Cooker Hood Frame for wallmounting
Systemair Residential Ventilation Systems Heat Recovery unit | 53
VTR 150/K
Supply
Extract
SFP 2,5
SFP 2,0
SFP 1,5
SFP 1,2
An intergral cooker hood is fitted as standard to this unit
•Highefficiencyrotaryheatexchanger•EnergyefficientRadical-fans,withmodernEC-technology•Separatesettingsofsupplyandextractairflow•Start-upwizardforeasycommissioning•Moderndesignwithintegratedcookerhood–VTR150/K•Automaticchangetosummeroperation(without heat recovery)•Demandcontrolregulation•Lowsoundlevel
SAVE VTR 150/K has an integrated cooker hood and should be placed above the hob. The unit has been adapted to suit different kitchen environments, with a modern design.The customer has the choice of choosing between a white or stainless steel front. The unit is controlled by a separate control panel. SAVE VTR 150/K is adapted for ventilation of smaller houses and apartments with an area of 100 m² . The extract air from the cooker hood is by-passed, hence the heat exchanger is not being exposed toextract air from the kitchen. The units are insulated against condensation.
VTR 150/K
Voltage/Frequency V/50 Hz 230
Power consumption per fanat operation point W ca. 15
100 m³/h at 80 Pa
SFP kW/m³/sWh/m³
1.10.3
Fuse A 10
Electr. re-heater W 500 or 1000
Filter, fresh air G 3, bag filter
Filter, extract air G 3, bag filter
Weight / incl. packaging kg 54
Dimension (L x B x H) mm 600 x 467 x 774
Connection DN 125
54 | Heat Recovery unit Systemair Residential Ventilation Systems
VTR150/K 500 W (S/S / White) 1000 W (S/S / White)
L handed S/S or White 18991 / 14991 18881 / 14881
R handed S/S or White 18990 / 14990 18880 / 14880
598*)
774
470**)
348
7
720
596191 293
84 99
102
237
133
Dimensions
MTP 20/20K p. 81
Potentiometer
Systemair Residential Ventilation Systems Heat Recovery unit | 55
Accessories
Extract
SFP 2,5
SFP 2,0
SFP 1,5
SFP 1,2
•Highefficiencyrotaryheatexchanger•EnergyefficientRadical-fans,withmodernEC-technology•Separatesettingsofsupplyandextractairflow•Start-upwizardforeasycommissioning•Moderndesignwithintegratedcookerhood–VTR150/K•Automaticchangetosummeroperation(without heat recovery)•Demandcontrolregulation•Lowsoundlevel
SAVE VTR 200/B is a white painted model with an integrated control panel in the front door. The optionfor connecting one or more external control panels is also available. Connection to an external cooker hood isavailable on the top of the unit. This makes the unit well suited for apartment buildings where the extract airfrom the cooker hood is challenging.SAVE VTR200/B is adapted for ventilation of smaller houses and apartments with an area of 140 m². Theextract air from the cooker hood is by-passed, hence the heat exchanger is not being exposed to extract air from the kitchen. The units are insulated against condensation.
VTR 200/B
Voltage/Frequency V/50 Hz 230
Power consumption per fanat operation point W ca. 18
100 m³/h at 80 Pa
SFP kW/m³/sWh/m³
1.270.35
Fuse A 10
Electr. re-heater W 500 or 1000
Filter, fresh air F 7, bag filter
Filter, extract air G 3, bag filter
Weight / incl. packaging kg 47
Dimension (L x B x H) mm 598 x 428 x 750
Connection DN 125
56 | Heat Recovery unit Systemair Residential Ventilation Systems
VTR 200/B 500 W 1000 W
Art-no. L handed 14993 14882
R handed 14992 14882
VTR 200/B
Supply
598428
366
750
598
207
191 12
4
77
340208
78
160
198
285
428
1180
598
416
799
627
29
982
Dimensions
Accessories
*
CD p. 81
Control panel
Systemair Residential Ventilation Systems Heat Recovery unit | 57
Wall bracket p. 83
Cooker Hood
Connection dim.: Ø125* Extract air from cooker hood
CEC p. 80
Cable
The VTC Low E Heat Recovery Ventilation unit is double skinned for quiet operation and prevent condensation forming. The unit is equipped with single inlet centrifugal fans on inlet and extract, filter on fresh air and extract, Counterflow heat exchanger, condensate drains and inspec-tion door in front. The fan speed is controlled in 2 or 3 steps either from the cookerhood or separate controller mounted on the wall.
The unit can be installed over the cooker, on the wall or in the roof space. Fresh air is supplied to living room and bedrooms and stale air is extract-ed via the cookerhood or louvre in the kitchen, utility room, bathroom and WC.Energy efficient fans with EC motors will reduce energy consump-tion for transportation of ventilation air by apx. 50 % compared to traditional AC motors. Modern technology gives low SFP factor (Specific Fan Power). G2 filters are delivered as standard, with the option for G3 or G4
Controlling the system from the Cookerhood
The unit is designed for connection to and for operation from a cooker-hood. The cookerhood is provided with special plugs for direct connec-tion if the cookerhood is installed under the unit.
Controlling the system from separate controller
The unit can be controlled from a wall mounted 2 or 3 step speed regula-tor
•Highefficiencycounterflowheatrecoveryunitupto86%
•EnergyefficientfanmotorswithmodernECtechnology
•Operationfromcookerhoodorwallmountedspeedcontroller
•Integralsummerby-pass
•IntegralHumidi-sensortoboostunitonriseinhumidityfromwet rooms.
•Unitavailablewithorwithoutcookerhood.
•DesigntoacceptKitchenfacepanelstoblendin.
•SAPAppendixQApproved.
Exhaust Terminal ConfigerationSpecific Fan Power (W/l/s)
Heat Exchanger Efficiency (%)
Energy Sav-ing Trust Best Practise Performance compliant
Kitchen +1 Additional wet room 0.76 86 Yes
Kitchen +2 Additional wet room 0.73 85 Yes
Kitchen +3 Additional wet room 0.83 85 Yes
Kitchen +4 Additional wet room 1.02 84 No
Kitchen +5 Additional wet room 1.04 83 No
Art-no. 52083
VTC Low E
58 | Heat Recovery unit Systemair Residential Ventilation Systems
TSL-1/EC Cookerhood
SAP Appendix Q Approved
η
SFP 1,2
SFP 1,5
SFP 2,0SFP 2,5
[l/s]
Supply Extract
TSL-1EC pg 83
MTP Controller
SFP = Specific Fan Power (kW/m3/s)The SFP value stated applies to the complete unit.
Dimension
Systemair Residential Ventilation Systems Heat Recovery unit | 59
VR 300 ECV/B • 81 % heat recovery efficiency
• Designedairflowuptoabout210m³/hat120Pa(forapp.130m² living space)
• Humidityrecovery:nocondensateconnection,nofrostpro-tection
• Freeselectableairvolumein3steps
• Forwallmounting
• Remote control CD necessary
The VR 300 ECV/B is a compact unit for ventilation of homes and primarily developed for wall mounted installation but can be installed horizontally e.g. in a false ceiling. The unit is double skinned, fully insulated, equipped with centrifugal fans for sup-ply/extract air, rotating heat exchanger, filters and thermostat operated re-heater battery. VR 300 ECV/B is equipped with large inspection hatches on both sides and is by that means reversible for optimal and simple duct connections. The cooker hood can be connected via duct on the top of the unit if it is placed sepa-rate from the kitchen. As an alternative, a cooker hood can be installed directly under the unit. The extract air from the cooker hood is drawn via an integrated bypass duct directly to the ex-tract fan bypassing the exchanger block. The airflow is set from a cooker hood or a separate control switch.
VR 300 ECV/B
Voltage/Frequency V/50 Hz 230
Power consumption per fanat operation point W ca. 40
140 m³/h at 80 Pa
SFP kW/m³/sWh/m³
1,890,5
Input power, fan motor(s) W 2x100
Input power, electrcal heating battery W 1000
Recommended fuse A 10
Filter, supply air F 7, bag filter
Filter, extract air G 3, bag filter
Weight kg 40,6
Dimension (L x B x H) mm 598 x 326 x 630
Connections DN 125
Surrounding
Mid-frequency band, Hz
LwA dB(A) Tot 63 125 250 500 1k 2k 4k 8k
Extract 54 42 51 43 47 48 37 26 22
Supply 70 59 61 61 63 65 60 52 43
Surrounding 43 24 37 38 36 33 29 23 15
Supply
Extract
VR 300ECV/B
VR 300ECV/B
Sound dataThe sound data tables indicate the sound power level LwA, which should not be confused with the sound pressure level LpA.
SFP= Specific Fan Power [kW/m3/s]The SFP value stated applies to the complete unit.
A cooker hood can be installed directly under the unit page 81.
500 W 1000 W
Art-no. 12519 12520
60 | Heat Recovery unit Systemair Residential Ventilation Systems
Duct connection ø125mmA Supply airB Exhaust airC Outdoor airD Extract airE Cooker hood (Alt. connection)F Cooker hood
F
A
BC D
E
A
B
C
DE
Dimensions
Scheme
SS
ETOT
SFL
EF
ELH
BD
BD
SF EFL
HE
SF Supply fanEF Extract fanSFL Supply filterEFL Extract filterSS Supply air temp. sensorHE Heat exchangerELH Electric heaterOT Overheating thermostatET Emergency thermostatBD Bypass duct
Accessories
MTP 20/20K p. 81
Potentiometer Exhaust Terminal Configeration
Specific Fan Power (W/l/s)
Heat Exchanger Efficiency (%)
Kitchen +1 Additional wet room 1.73 77
Kitchen +2 Additional wet room 1.69 80
Kitchen +3 Additional wet room 1.69 80
Kitchen +4 Additional wet room 1.66 81
Systemair Residential Ventilation Systems Heat Recovery unit | 61
Wall bracket p. 83
Cooker Hood
SAP Appendix Q Approved
VR 400 DCV/B • High efficiency heat recovery unit without need for defrosting
• Energy efficient fan motors with modern EC technology.
• Operation from user friendly control panel, type CD with LCD-display, included
• Separate setting of supply and extract airflow.
• Constant airflow and balance between extract and supply air.
• Changes automatically to summer operation with no heat recovery.
• Flexible installation. No need for condensation drain.
• Suited for demand control.
• Modbus communication via RS-485
DCV(/B) units are designed for installation on wall, in laundry rooms, utility rooms or similar. With the white painted door and side panels the unit can easily be installed to blend in with the surroundings. Large inspection doors simplifies inspection and service. The VR 400 DCV/B has a by-pass function which allows the unit to be connected to a kitchen hood. The polluted air from the hood is led directly to the extract fan without coming in con-tact with the rotating heat exchanger.
VR 400 DCV/B
Voltage/Frequency V/50 Hz 230
Power consumption per fanat operation point W ca. 65
260 m³/h at 80 Pa
SFP kW/m³/sWh/m³
1,820,5
Recommended fuse A 10
Input power, fan motor(s) W 2x114
Input power, electr. heating battery W 1670
Filter, supply air F 7, bag filter
Filter, extract air G 3, bag filter
Weight / incl. packaging kg 56,4
Dimension (L x B x H) mm 796 x 406 x 800
Connection DN 160/125
Surrounding
Mid-frequency band, Hz
LwA dB(A) Tot 63 125 250 500 1k 2k 4k 8k
Extract 56 46 48 51 52 45 39 28 20
Supply 66 52 55 56 58 62 60 52 46
Surrounding 47 29 35 37 41 41 41 35 30
Supply
Extract
VR 400DCV/B
VR 400DCV/B
Sound dataThe sound data tables indicate the sound power level LwA, which should not be confused with the sound pressure level LpA.
SFP= Specific Fan Power [kW/m3/s]The SFP value stated applies to the complete unit.
Art-no. 12314
62 | Heat Recovery unit Systemair Residential Ventilation Systems
Dimensions
Scheme80
0
796406
110 174 203 19917
074
118
101
67
A B
C
D
E
216 186 174 110
118
101
67
7417
0AB
C D
E
Left hand version
Right hand version
A Supply air ø160 mmB Exhaust air ø160 mmC Outdoor air ø160 mmD Extract air ø160 mmE Cooker hood ø125 mm
F7 Filter fresh airVR Rotating heat recovery unitEF Extract fanG3 Filter extract airETS Extract air temp. sensorSF Supply fanEH Electric heater SS Supply air temp. sensor OT Overheating thermostatET Emergency thermostatEHS Temp. sensor as rotating controllerFS Fresh air temp. sensor
Accessories
CD p. 81
Control panel
Exhaust Terminal Configeration
Specific Fan Power (W/l/s)
Heat Exchanger Efficiency (%)
Kitchen +2 Additional wet room 1.68 75
Kitchen +3 Additional wet room 1.50 77
Kitchen +4 Additional wet room 1.47 78
Kitchen +5 Additional wet room 1.45 79
Kitchen +6 Additional wet room 1.49 81
Kitchen +7 Additional wet room 1.57 81
CEC p. 80
Cable
Systemair Residential Ventilation Systems Heat Recovery unit | 63
Wall bracket p. 83
Cooker Hood
SAP Appendix Q Approved
VR 700 DCV • High efficiency heat recovery unit without need for defrosting will give the highest average efficiency over the year
• Energy efficient fan motors with modern EC technology
• Operation from user friendly control panel(s), type CD with LCD-display, included
• Separate setting of supply and extract airflow
• Constant airflow and balance between extract and supply air
• Changes automatically to summer operation with no heat recovery
• Flexible installation. No need for condensation drain
• Modbus communication via RS-485
The VR 700 DCV is designed for installation in laundry room, storeroom or cupboard. The unit is double skinned, fully insulat-ed and with complete control functions, high efficiency rotating heat exchanger, thermostat operated re-heater battery and filters.
The unit will automatically alternate between normal operation with heat recovery and summer operation without heat recovery. This solution will also automatically recover chilled indoor air (from cooling).
VR 700 DCV
Voltage/Frequency V/50 Hz 230
Power consumption per fanat operation point W ca. 130
450 m³/h at 80 Pa
SFP kW/m³/sWh/m³
2,050,6
Recommended fuse A 13
Input power, fan motor(s) W 2x240
Input power, electr. heating battery W 1670
Filter, supply air F 7, bag filter
Filter, extract air G 3, bag filter
Weight / incl. packaging kg 72,6
Dimension (L x B x H) mm 918 x 517 x 800
Connection DN 200
Surrounding
Mid-frequency band, Hz
LwA dB(A) Tot 63 125 250 500 1k 2k 4k 8k
Extract 57 42 45 55 51 42 40 32 26
Supply 72 55 60 64 65 66 65 60 53
Surrounding 50 36 43 45 42 43 40 33 28
Supply
Extract
VR 700DCV
VR 700DCV
Sound dataThe sound data tables indicate the sound power level LwA, which should not be confused with the sound pressure level LpA.
SFP= Specific Fan Power [kW/m3/s]The SFP value stated applies to the complete unit.
Art-no. 12425
64 | Heat Recovery unit Systemair Residential Ventilation Systems
Dimensions
Scheme
918
Appr
ox. 8
00 517
5080
0
181
150
118 176 202 280
216A B
C
Dø200 (4x)
A Supply airB Exhaust airC Outdoor airD Extract air
F7 Filter fresh airVR Rotating heat recovery unitEF Extract fanG3 Filter extract airETS Extract air temp. sensorSF Supply fanEH Electric heater SS Supply air temp. sensor OT Overheating thermostatET Emergency thermostatEHS Temp. sensor as rotating controllerFS Fresh air temp. sensor
Accessories
CD p. 81
Control panel
CEC p. 80
Cable
Systemair Residential Ventilation Systems Heat Recovery unit | 65
WBK p. 81
Wall bracket
η
VSR 300Voltage/Frequency V/50 Hz 230
Power consumption per fanat operation point
W ca. 50270 m³/h at 80 Pa
SFP kW/m³/sWh/m³
1.250.35
Recommended fuse A 10
Input power, fan motor(s) W 2 x 83
Input power, electr. heating battery W 1670
Filter, supply air F 7
Filter, extract air G 3
Weight kg 61
Dimension (L x H x D) mm 1120 x 582 x 461
Connection DN 160
Surrounding
Mid-frequency band, Hz
LwA dB(A) Tot 63 125 250 500 1k 2k 4k 8k
Supply 67 57 59 60 57 62 58 53 49
Extract 53 41 49 49 44 44 42 34 27
Surrounding 48 30 38 42 38 42 42 34 29
SFP 1,2
SFP 1,5
SFP 2,5
SFP 2,0
Supply
Extract
• High efficiency heat recovery unit without need for defrosting
• Energy efficient fan motors with modern EC technology
• Operation from user friendly control panel, type CD with LCD-display as accessory
• Separate setting of supply and extract airflow
• Constant airflow and balance between extract and supply air
• Changes automatically to summer operation with no heat recovery
• Flexible installation. No need for condensation drain
• Modbus communication via RS-485
The VSR 300 is double skinned, fully insulated and with com-plete control functions, high efficiency rotating heat exchanger, thermostat operated re-heater battery and filters. Energy efficient fans with EC motors will reduce energy consumption for trans-portation of ventilation air by approx. 50 % compared to tradi-tional AC motors. Modern technology gives low SFP factor (Spe-cific Fan Power) as well as constant airflow and balance between extract and supply air.
Sound dataThe sound data tables indicate the sound power level LwA, which should not be confused with the sound pressure level LpA.
SFP= Specific Fan Power [kW/m3/s]The SFP value stated applies to the complete unit.
VSR 300
Art-no. 19427
66 | Heat Recovery unit Systemair Residential Ventilation Systems
1040
582
461
505
112
231
188
178
160
136
281
602
1120
Dimensions
Scheme
F7 Filter fresh airVR Rotating heat recovery unitEF Extract fanSF Supply fanETS Extract air temp. sensorEH Electric heaterG3 Filter extract airSS Supply air temp. sensorOT Overheating thermostatET Emergency thermostatEHS Temp. sensor as rotating controller
Systemair Residential Ventilation Systems Heat Recovery unit | 67
Accessories
CD p. 81
Control panel
WBK p. 81
Wall bracket
CEC p. 80
Cable
SFP 1,2
SFP 1,5
SFP 2,5
SFP 2,0
η
Extract
Supply
VSR 500 Voltage/Frequency V/50 Hz 230Power consumption per fanat operation point
W ca. 95450 m³/h at 100 Pa
SFP kW/m³/sWh/m³
1.440.4
Recommended fuse A 13Input power, fan motor(s) W 2 x 169Input power, electr. heating battery W 1670Filter, supply air F 7Filter, extract air G 3Weight kg 72Dimension (L x H x D) mm 1120 x 632 x 551Connection DN 200
• High efficiency heat recovery unit without need for defrosting
• Energy efficient fan motors with modern EC technology
• Separate setting of supply and extract airflow
• Constant airflow and balance between extract and supply air
• Changes automatically to summer operation with no heat recovery
• Flexible installation. No need for condensation drain
• Inspection hatch on both sides
• Modbus communication via RS-485
• Control panel CD necessary
The VSR 500 is double skinned, fully insulated and with complete control functions, high efficiency rotating heat exchanger, thermostat operated re-heater battery and filters. Modern technology gives low SFP factor (Specific Fan Power) as well as constant airflow and balance between extract and supply air.
The unit will automatically alternate between normal operation with heat recovery and summer operation without heat recovery. This solution will also automatically recover chilled indoor air (from cooling).
SurroundingMid-frequency band, Hz
LwA dB(A) Tot 63 125 250 500 1k 2k 4k 8kExtract 62 44 50 57 58 49 47 40 29
Supply 77 61 65 68 70 70 70 66 61
Surrounding 54 36 44 45 50 46 46 42 41
Sound dataThe sound data tables indicate the sound power level LwA, which should not be confused with the sound pressure level LpA.
SFP= Specific Fan Power [kW/m3/s]The SFP value stated applies to the complete unit.
VSR 500
68 | Heat Recovery unit Systemair Residential Ventilation Systems
Art-no. 19441
Dimensions
Scheme
1040
632
551
595
123
276
178
208
207
179
276
652
345
1120
F7 Filter fresh airVR Rotating heat recovery unitEF Extract fanSF Supply fanETS Extract air temp. sensorEH Electric heaterG3 Filter extract airSS Supply air temp. sensorOT Overheating thermostatET Emergency thermostatEHS Temp. sensor as rotating controller
Systemair Residential Ventilation Systems Heat Recovery unit | 69
Accessories
CD p. 81
Control panel
WBK p. 81
Wall bracket
CEC p. 80
Cable
70 | Heat Recovery unit Systemair Residential Ventilation Systems
TECHNICAL DATA VX 400 E VX 400 EV VX 700 E VX 700 EV
Voltage/Frequency V/50Hz 230 230 230 230
Phase — 1 1 1 1
Input power, fan motors W 2x152 2x138 2x308 2x315
Input power, preheater battery kW 1.67 1.67 2.67 2.67
Input power, electrical heater battery kW 1.67 1.67 2.67 2.67
Fuse A 10 10 16 16
Enclosure class IP 24 24 24 24
Weight Kg 48 52.6 67 69
Filter, supply air — F7 F7 F7 F7
Filter, extract air — Aluminium Aluminium Aluminium Aluminium
ACCESSORIES VX 400 E VX 400 EV VX 700 E VX 700 EV
Control panel CE CE CE CE
Cable w/plug 12m CEC CEC CEC CEC
Diverging plug CED CED CED CED
Timer T 120 T 120 T 120 T 120
Timer frame F-T 120 F-T 120 F-T 120 F-T 120
Week timer 7592H 7592H 7592H 7592H
Filter F7 (Supply air) BFVX 400E/EV EU7 BFVX 400E/EV EU7 BFVX 700E/EV EU7 BFVX 500/700 E/EV EU7
Filter G3 (Extract air) PFVX 400 E/EV PFVX 400 E/EV PFVX 400 E/EV PFVX 500/700
Duct cover VTVX 400 VTVX 400 VTVX 500/700 VTVX 500/700
Combi grille CVVX 160 CVVX 160 CVVX 200 CVVX 200
Summerblock SBVX 400 SBVX 400 SBVX 500/700 SBVX 500/700
Condensate tray KVSX 200-700 KVSX 200-700 KVSX 200-700 KSVX 200-700
• User friendly controlling by one or several control panels.
• Integral filter monitor
• Automatic de-frosting for all operating conditions.
• EU7 fine filter for supply-air
• Cross flow heat exchanger
• Demand control
• Inspection covers on both side
Fans for supply and extract air, control system, cross flow heat exchanger, thermostat operated pre- and re-heater battery and filters are standard. Summer block is available as an accessory when heat recovery is not required.Air flow, supply air temperature and filter change interval are set from one (or several) external mounted control panels type CE. Lamp indicators on the CE panel shows chosen fans and temperature settings, whether the heating battery is in operation and if filters need to be replaced. The lamps also help to show if any faults would occur. A separate timer can be connected for programming day and night operation. A CO2 or presence sensor (potential free contact) can be connected for demand control. The casing is manufactured in galvanised sheet steel, double skinned with 50 mm of insulation in the main body and 30 mm in the access covers.
VX 400 & 700 E / EV
VX 400 E Horizontal VX 700 E Horizontal
Art-no. 12040 12042
VX 400 EV Vertical VX 700 EV Vertical
Art-no. left / Right 12045 / 12044 12049 / 12048
Systemair Residential Ventilation Systems Heat Recovery unit | 71
dimensionsVx 400 E
5060
0
102
164
172
281
149
327
179
267
155
112
163
163
1189 1080
ø125
ø160
ø160
ø160
Vx 400 EV
Vx 700 EV
Vx 700 E
115
315
170
250
600
51
500
171
260
170
110
250
1189 1080
ø200(x4)
72 | Heat Recovery unit Systemair Residential Ventilation Systems
Performance
Vx 400 E
A
B
C
A
B
C
With air ratio 1:1 and air humidity at 50%
SUPPLy AIR ExTRACT AIR TEMPERATURE EFFICIENCy
VX 400 e ocTaVe Band (mid-frequency Hz)
Tot 63 125 250 500 1k 2k 4k 8k
Lwa dB(a) a B c a B c a B c a B c a B c a B c a B c a B c a B c
supply air 72 65 54 64 54 47 63 59 47 63 55 44 62 55 45 64 59 49 64 55 43 58 51 37 53 45 28
extract air 58 51 42 36 36 34 47 41 31 55 47 35 54 46 38 47 40 32 40 32 22 33 23 8 24 15 6
surrounding 52 46 36 36 29 22 46 41 31 43 36 25 47 41 32 44 37 28 39 31 21 29 22 7 22 15 0
Vx 400 EV
A
BC
A
B
C
With air ratio 1:1 and air humidity at 50%
SUPPLy AIR ExTRACT AIR TEMPERATURE EFFICIENCy
VX 400 eV ocTaVe Band (mid-frequency Hz)
Tot 63 125 250 500 1k 2k 4k 8k
Lwa dB(a) a B c a B c a B c a B c a B c a B c a B c a B c a B c
supply air 70 62 53 58 50 43 59 54 44 63 55 44 61 53 45 64 58 47 64 52 42 56 47 33 48 37 22
extract air 61 54 44 54 46 40 57 52 40 52 44 32 52 45 36 49 43 32 47 37 25 35 23 7 24 15 8
surrounding 51 44 33 40 31 23 42 36 26 44 36 25 41 34 26 44 40 28 43 33 21 36 27 13 29 19 9
Systemair Residential Ventilation Systems Heat Recovery unit | 73
Vx 700 E
Vx 700 EV
A
B
C
A
BC
A
B
C
A
B
C
With air ratio 1:1 and air humidity at 50%
With air ratio 1:1 and air humidity at 50%
SUPPLy AIR
SUPPLy AIR
ExTRACT AIR
ExTRACT AIR
TEMPERATURE EFFICIENCy
TEMPERATURE EFFICIENCy
VX 700 e ocTaVe Band (mid-frequency Hz)
Tot 63 125 250 500 1k 2k 4k 8k
Lwa dB(a) a B c a B c a B c a B c a B c a B c a B c a B c a B c
supply air 75 71 57 64 59 50 69 65 52 68 63 47 66 61 44 67 64 51 67 63 48 64 59 42 57 52 31
extract air 60 54 44 34 34 31 49 46 34 55 48 40 55 49 37 51 45 34 46 39 24 43 33 17 36 27 24
surrounding 59 48 39 46 33 25 52 43 34 52 41 32 55 44 34 45 36 27 45 34 24 40 31 16 38 22 24
VX 700 eV ocTaVe Band (mid-frequency Hz)
Tot 63 125 250 500 1k 2k 4k 8k
Lwa dB(a) a B c a B c a B c a B c a B c a B c a B c a B c a B c
supply air 73 64 54 63 55 47 64 55 45 66 56 45 66 56 48 65 57 48 66 56 46 51 50 38 55 40 28
extract air 69 65 54 63 61 51 62 58 48 64 57 46 61 54 45 53 48 40 50 43 33 45 38 29 37 30 24
surrounding 58 51 41 46 40 31 50 45 34 55 46 35 49 42 33 46 40 32 44 37 27 43 34 24 38 28 24
CE p. 80 Timer p. 80CEC p. 80 TFV p. 80 RCE p. 80
Control panel Cable Timer Timer Frame for wallmounting
9294
/929
5T
SFP 1,2
SFP 1,5
SFP 2,0SFP 2,5
9294
/929
5F
Exhaust
Supply
• High efficiency heat recovery unit
• Energy efficient fan motors with modern EC technology
• Operation from user friendly control panel(s), type CD with LCD-display, included
• Separate setting of supply and extract airflow
• Changes automatically to summer operation with no heat recovery
• Automatic defrosting
• Modbus communication via RS-485
The SAVE VTC 300 is designed for installation on wall, in laun-dry room, storeroom. The unit is double skinned, fully insulated and with complete control functions, high efficiency counterflow heat exchanger and filters. Modern technology gives low SFP fac-tor (Specific Fan Power).
The unit will automatically alternate between normal operation with heat recovery and summer operation without heat recovery. This solution will also automatically recover chilled indoor air (from cooling).
VTC 300
VTC 300Voltage/Frequency V/50Hz 230
Power consumption per fanat operation point W ca. 55 I ca. 70
350 m³/h at 80 Pa
SFP kW/m³/sWh/m³
1,140,3
1,410,39
Recommended fuse A 10Input power, fan motor(s) W 2 x 85Filter, supply air G4 F7Filter, extract air G4 F7Weight kg 72
Dimension (L x B x H) mm 762 x 616 x 857
Connection DN 160
Sound dataThe sound data tables indicate the sound power level LwA, which should not be confused with the sound pressure level LpA.
SFP= Specific Fan Power [kW/m3/s]The SFP value stated applies to the complete unit.
SurroundingMid-frequency band, Hz
LwA dB(A) Tot 63 125 250 500 1k 2k 4k 8k
Extract 56 45 43 54 45 46 43 30 22
Supply 66 47 53 62 59 57 60 53 46
Surrounding 47 28 35 44 40 37 35 28 22
VTC 300 R VTC 300 L
Art-no. 2480 2481
74 | Heat Recovery unit Systemair Residential Ventilation Systems
Dimensions
762616
553
857
802
421
139
131279
131
139
406
Ø160 (4x)
A
B C
D616
VTC 300 - Left hand version
A Supply airB Exhaust airC Outdoor airD Extract air
Scheme
EF exhaust air fanG4 supply air filterETS temperature sensor, exhaust airSF supply air fanSS supply air sensorOT overheating sensorET safety temperature limiterELH electric reheaterFS supply air temperature sensorDB bypass flapHE heat exchanger
EFD p. 80
Damper
Exhaust Terminal Configeration
Specific Fan Power (W/l/s)
Heat Exchanger Efficiency (%)
Kitchen +1 Additional wet room 0.89 75
Kitchen +2 Additional wet room 0.81 76
Kitchen +3 Additional wet room 0.79 76
Kitchen +4 Additional wet room 0.83 78
Kitchen +5 Additional wet room 0.90 80
Kitchen +6 Additional wet room 1.01 80
Kitchen +7 Additional wet room 1.14 80
Systemair Residential Ventilation Systems Heat Recovery unit | 75
SAP Appendix Q Approved
Accessories
CD p. 81
Control panel
CEC p. 80
Cable
Exhaust
Supply
• High efficiency heat recovery unit
• Energy efficient fan motors with modern EC technology
• Operation from user friendly control panel(s), type CD with LCD-display as accessory
• Separate setting of supply and extract airflow
• Changes automatically to summer operation with no heat recovery
• Automatic defrosting
• Modbus communication via RS-485
The SAVE VTC 700 is designed for installation on wall, in laundry room, storeroom. The unit is double skinned, fully insulated and with complete control functions, high efficiency counterflow heat exchanger and filters. Modern technology gives low SFP factor (Specific Fan Power).
The unit will automatically alternate between normal operation with heat recovery and summer operation without heat recovery. This solution will also automatically recover chilled indoor air (from cooling).
VTC 700
SFP 1,2
SFP 1,5
SFP 2,0SFP 2,5
SFP 1,6
SFP 0,9SFP 0,6
Sound dataThe sound data tables indicate the sound power level LwA, which should not be confused with the sound pressure level LpA.
SFP= Specific Fan Power [kW/m3/s]The SFP value stated applies to the complete unit.
SurroundingMid-frequency band, Hz
LwA dB(A) Tot 63 125 250 500 1k 2k 4k 8k
Extract 65 44 50 56 57 59 61 51 45
Supply 50 34 40 46 41 43 38 24 21
Surrounding 47 24 35 42 40 40 39 32 25
VTC 700
Voltage/Frequency V/50Hz 230
Power consumption per fanat operation point W ca. 95 I ca. 100
700 m³/h at 80 Pa
SFP kW/m³/sWh/m³
0,970,27
1,020,28
Recommended fuse A 10
Input power, fan motor(s) W 2 x 168
Filter, supply air G4 F7
Filter, extract air G4 F7
Weight kg 150
Dimension (L x B x H) mm 1170 x 860 x 1214
Connection DN 250
VTC 700 R VTC 700 LArt-no. 2173 2174
76 | Heat Recovery unit Systemair Residential Ventilation Systems
DimensionVTC 700 - Left hand version
1170 860780
176450
180
ø250(4x)
A
B C
D
1214 10
88
576
211
211
571
A Supply airB Exhaust airC Outdoor airD Extract air
Accessories
CD p. 81
Control panel
Scheme
EFSF
SSETS
G4
FS
Fresh air Exhaust air Supply air Extract air
G4
DB
ELHETOT
HE
EF exhaust air fanG4 supply air filterETS temperature sensor, exhaust airSF supply air fanSS supply air sensorOT overheating sensorET safety temperature limiterELH electric reheaterFS supply air temperature sensorDB bypass flapHE heat exchanger
Systemair Residential Ventilation Systems Heat Recovery unit | 77
EFD p.80
Damper
CEC p. 80
Cable
78 | Controls Systemair Residential Ventilation Systems
• Easy operation
• 3 or 4 step speed control
• 5 steps temperature control (12-22 °C)
• Setting of filter replacement intervals (3, 6, 9 months)
• Dimensions: 155 x 8.5 mm
This remote control is necessary for VR 250 ECH/B. It is also possible to connect more than one remote control at the same time. The remote control CE has an appealing design and is functionally and easy to operate. The fan speeds and the supply
temperatures can easily be adjusted by the handy keyboard. Indicator lights show the chosen settings and the operation of the electric heater. A separate control lamp shows when the filter should be changed.A low voltage cable with plug-in connections allows an easy installation. The remote control can be mounted on-wall (by a corresponding mounting frame) or in-wall (in-wall socket as an accessory). The mounting frame (accessory) for on-wall mounting has a height of app. 20 mm.For application of heat recovery units in kindergartens, schools or office rooms, a separate time switch can be connected for depression or normal operation. It is possible to deactivate depression operation for 3 hours by a so called “party button”.A low voltage wire (2 x 0.8 mm²) must be connected between time switch and unit for depression operation.
Only for VR-250 ECH/B
Circular shutter damperThe damper is provided with 230 V mo-tors with spring-return actuators. EFD are made in leakage performance class 3 according to EN 1751:1998 Annex C.2. Outdoor/exhaust air damper have the function to prevent the hot water battery to freeze. EFD connects to a connection block inside the electrical box.
Control panel CE
CEC - Cable c/w PlugCable to connect CE Controller to unit
RCE
Timer An electronic day/week timer with an au-tomatic summer/winter time setting.Frame “F7592H” is available for wall mounting.
TFV, Timer suitable from 0-6 hours.
TFV
Frame for wallmounting of CE Control panel.
EFD
EFD No. øA160 7122 160200 7162 200
250 6748 250
100170
10
175
45 45
13025
95 210
øA50
6773
CEC
12m Cable 12398
6m Cable 12283
Diverging plug 12399
RCE
Art-no. 12276
Timer
Art-no. 5589
TFV
Art-no. 12277
CE
Art-no. 12486
Systemair Residential Ventilation Systems Controls | 79
• Plain text display
• Easy operation
• 3 steps control (steps free selectable)
• Supply and exhaust air ventilator can be equalised
• Temperature control 12-22 °C
• Weekly time switch integrated
• Setting of filter replacement intervals
• Dimensions: 80x88x20mm (WxHxD)
Control Panel for almost all units!
This remote control is necessary for (type -DC). It is possible to connect up to 3 remote controls at the same time.
Remote control CD is already integrated in the front of wall units (type – DCV). It is possible to connect up to two remote controls type CD. Automatic control units are already installed and presetted in the units.
The remote control CD has an appealing, functional design and is easy to operate by a selection knob and two buttons. The unit can be operated manually or by the integrated time switch for day and night operation.
The control program offers two user levels: user level and service level. The user level allows adjusting air volume and temperature; filter replacement intervals, heating and cooling operation etc. can be read. Parameters and basic settings can be changed in the service level.
The built-in control unit enables to control speeds via potential-free relays
(also suitable for monitoring the differential pressure in combination with wood stoves).
The function of these relays can be set with the remote control CD. Additional close and push-button contacts (heating ON/OFF, external ON/OFF, filter reset, vacation operation) are fixed preset and can be used when needed.
Each external cooling and heating coil can be controlled by a 0-10 V signal (power supply 24V on site).
A 4-wire low voltage wire (2x2x0.8 mm²) as a control cable is sufficient. Use a shielded cable when installed in combination with a 230 V cable.
Potentiometer for speed control in 3-steps, Min 3-7V, Norm 5-9V, 10V - Combined flush or surface mountingFor the manual control of speed and air flow of electrical fans with 0-10V output. The jetproof IP 54 enclosure is achieved
with the included surface mounting case. (Flush-mounting without the surface mounting case,gives a splash proof IP 44 enclosure also suitable for highly demand environments as bathrooms etc).
Only for VR-300 ECH/B & VTC Low E
For VR-400/700 and Save VTC /VSR units
Control panel CD No. 207487
MTP 20/20KNo. 4744
WBK 315/355 No. 2721
Wall mounting bracket. Manufactured from galvanised steel. The corners are welded. Available in pairs. For VR-400/70 DC
Wall bracket No. 12891
Wall bracket for VR 250.
80 | Heating & Cooling Coils Systemair Residential Ventilation Systems
Product Range Degree of protection
Duct sensor TG-K330 0-30°C IP20
Duct sensor TG-K360 0-60°C IP20
Room sensor TG-R430 with setpoint adjustment 0-30°C IP30
Room sensor TG-R530 0-30°C IP30
Pressure switch DTV200 incl. con-nection kit
20-300 Pa; max. 5A, 230V~ IP54
Accessories CB
CB - Electric re-heater coil CB – circular electric duct heater down to 0.5 m/s air velocityThe CB can be used for preheating and reheating air in residential ventilation sys-tems. The casing is made of Aluzinc-coated steel and the heater elements are of stainless steel (EN1.4301). The CB has a built in regulation for easy installation (pro-tection IP43). It is equipped with two overheating protections, one with automatic reset and one with manual reset. Not to lose heated air through the casing, it con-firms air tightness class C. The max. outlet air temperature is limited to 50°C. Available is sizes 100mm Dia to 500mm Dia
VBC - Water LPHW re-heater coil
CWK - Water-cooling coil
VBC - Water-heating battery for heating air in ventilation systems with circular ducts. Aluzinc-coated casing, heat transmission element with copper tubes and aluminium fins. Removable cover for cleaning the unit. The water-heating battery can be installed in a horizontal or a vertical duct with optional direction of airflow.Max operating temperature 150 °CMax operating pressure 1,6 MPa (16Bar)2-rows batteryAvailable is duct sizes 100mm to 500mm diameter
CWK - Water-cooling battery for circular ductsCasing of galvanised sheet steel with copper tubes and aluminium fins. Inspection covers for easy cleaning and maintenance. Connection sleeves with rubber seal.Max operating temperature 150 °CMax operating pressure 1,6 MPa (16Bar)Available is duct sizes 100mm to 400mm diameter
Systemair Residential Ventilation Systems Cooker Hoods | 81
Functional design and high efficiency, even at a low airflow. Developed for con-nection to Villavent heat recovery unit type VR-250 EH/B and VR-400 EV/B and to central extract fans serving more than one apartment.
A modern and functional cookerhood with a high efficiency even at a low air-flow (75% at 140 m3/h). The aluminium
Cooker hood251-10/B
filter can easily be removed for cleaning in warm soapy water or in dish washer. A patented, adjustable damper solution allows for individual setting of airflow at normal ventilation. The cookerhood has a damper with a timer (5-60 min.) and a wired out signal to force the airflow in the airhandling unit.
This model is available white painted or in stainless steel.
Connections:Voltage/frequency 230V/50 Hz2 x 1,0 mm²Ductwork connection spigot DN 125mm white 12023
stainless steel 12929
Cooker hood251-14
white 4742stainless steel 4741
Functional design and high efficiency, even at a low airflow. Developed for con-nection to Systemair heat recovery unit type VR-300 ECV/B.
Modern cookerhood with curved front and good working light from 11 W com-pact light tube. No sharp edges allows for
easy cleaning. The cookerhood is func-tional with deep side members and shade in tempered glass. This makes the cooker-hood efficient, even at low airflows (75% at 140 m3/h). The aluminium grease filter can easily be removed for cleaning in warm soapy water or in dish washer. The cookerhood is equipped with switch for timer control of damper, 5 to 60 minutes, and signal cable for damper/fan speed control (airflow) in the ventilation unit. This model, for installation under kitchen cupboard, is available in white or stain-less steel.
598
9,5 38329916
22
511
480
190 16
070
8023
2
50 13
Cooker hoodTSL-1/EC
The TSL-1/EC cookerhood is designed to be used with the VTC Low E Heat Recov-ery Unit.The units is complete with Fan speed control switch, Hob light switch, Metal Grease filter section and connection plugs for quick in-stallation to HRU. To activate the extraction, simply slide the cookerhood telescopic sec-tion towards you.The units front comes in white as standard, with a stainless steel cover plate as an op-tional extra.
white 52072stainless steel cover plate 14236
82 | Duct work & Fittings Systemair Residential Ventilation Systems
Systemair Duct SystemsVery flexible
Spiral seam pipe or plastic pipe systemSystemair offers spiral seam pipes in round and oval versions (flat duct) and Systemair-Flex+ plastic pipes, “The NEW semi-rigid”. All inner sides are smooth and therefore aerodynamical and easy to clean.
Dimensioning of duct systemsThe dimensioning of the ducts for the ventilation system is made according to the requirements of the unit (calculation of the required supply air according to DIN 1946-6) and according to the situation in the building. Flow engineering and acoustic properties have first priorities.The duct installation has to be coordinated early enough with other crafts on site.
The duct size depends on the air volume. To avoid high pressure losses and unwanted noise, we recommend an air velocity of max. 3 m/s in the main duct.
When round, rectangular or oval ducts are used, the air velocity is lower at the same pressure loss in the duct.Different diameters must not be proportional installed. The pressure differences between the longest and the shortest sections have to be reduced to guarantee the previously defined air flow for all air outlets.
Round pipe (spiral seam pipe) with telescopic pipeFor duct systems with spiral seam
pipes, Systemair uses folded spiral seam pipes with a length of 1.2 m as well as telescopic pipes. The elements are equipped with rubber-lip seals. The length of the telescopic pipe can be freely adjusted. The most important advantage of this duct system is that it can be installed without cutting or trimming work. This saves installation time and makes maintenance and cleaning easier.
All joints have to be fixed by sheet metal screws and also sealed with tape.
Oval duct / flat ductFlat ducts are made of galvanized steel sheet. The elements are made of stainless steel and are connected by a plug-in system. Fixing and sealing is made by cold shrink tape.
Available sizes: System 100 (129 x 52); length 3 mSystem 151 (208 x 52); length 3 m
Systemair Flex+ - the flexible plastic pipeThe Flex+ pipe is made of physiologically and toxicologically safe PVC with no recycling materials. Thus, it is neutral in odour, free of halogens, emission-free, antistatic and antibacterial.
Easy and time saving installation by a click system. Hermetically sealed connections ensure an absolutely air tight system without further sealing work. Therefore, it works economically and hygienically because no air can leak and no other substances can enter from outside.
Deliverable sizes: DiameterDN 50, 63, 75, 90
Systemair ISO+ - a perfect combination of heat and sound insulationOuter sheath made of polyethylene with high density (HDPE); inner sheath made of polyolefin with closed cell structure. Flexible fast clamp made of EPDM. The special design of the pipes provides thermical and acoustic insulation.
Systemair Residential Ventilation Systems Duct work & Fittings | 83
This pipe should be preferably used as a connection between unit and facade (fresh and extract air) and in unheated areas.
Available nominal widths (inner diameter): DN 125 and DN 180
Pipe kit availableVentilation systems from Systemair are individually planned for each building.The air volume is calculated according to DIN 1946-6, the unit is accordingly specified and the duct system is planned inclusive silencers, insulation, outlets and mounting material. The duct system is assembled and delivered according to the material list of the planning.
84 | SystemairFlex+ Plastic Duct
Air duct D outside[mm]
D inside[mm]
DN 50 51 41DN 63 64 54DN 75 76 64DN 90 91 78
Technical data SystemairFlex+
Pres
sure
loss
(Pa/
m)
Capacity (m³/h)
0
5
10
15
20
25DN50 [mm]
DN63 [mm]
DN75 [mm]
DN90 [mm]
0 5 10 15 20 25 30 35 40 45 50
Pressure loss data:
DN50 DN63 DN75 DN90Air flow in m³/h at ca.:
2m/s 2.5 m/s 3 m/s 2m/s 2.5 m/s 3 m/s 2m/s 2.5 m/s 3 m/s 2m/s 2.5 m/s 3 m/s
1 duct 10 m³/h 12.5 m³/h 15 m³/h 15 m³/h 20 m³/h 25 m³/h 22 m³/h 28 m³/h 34 m³/h 34 m³/h 42 m³/h 51 m³/h
2 ducts 20 m³/h 25 m³/h 30 m³/h 30 m³/h 40 m³/h 50 m³/h 44 m³/h 56 m³/h 68 m³/h
3 ducts 30 m³/h 37.5 m³/h 45 m³/h 45 m³/h 60 m³/h 75 m³/h
Leng
th o
f duc
t (m
)
2m/s 2.5 m/s 3 m/s 2m/s 2.5 m/s 3 m/s 2m/s 2.5 m/s 3 m/s 2m/s 2.5 m/s 3 m/s
2 7.6 10.0 12.6 4.0 5.6 8.4 2.6 4.0 6.0 2.6 4.0 5.4
4 15.2 20.0 25.2 8.0 11.2 16.8 5.2 8.0 12.0 5.2 8.0 10.8
6 22.8 30.0 37.8 12.0 16.8 25.2 7.8 12.0 18.0 7.8 12.0 16.2
8 30.4 40.0 50.4 16.0 22.4 33.6 10.4 16.0 24.0 10.4 16.0 21.6
10 38.0 50.0 63.0 20.0 28.0 42.0 13.0 20.0 30.0 13.0 20.0 27.0
12 45.6 60.0 24.0 33.6 50.4 15.6 24.0 36.0 15.6 24.0 32.4
14 53.2 28.0 39.2 58.8 18.2 28.0 42.0 18.2 28.0 37.8
16 60.8 32.0 44.8 20.8 32.0 48.0 20.8 32.0 43.2
18 36.0 50.4 23.4 36.0 54.0 23.4 36.0 48.6
Pressure (Pa)
Pressure loss diagram: Nominal dimensions:
SystemairFlex+ plastic duct system „The NEW semi-rigid“
SystemairFlex+ Plastic Duct | 85
Applications
In the concrete:
Concrete floor plates
Cast-in-place concrete
In a false ceiling:
TT TT
In a modular ceiling: In a reduced wooden ceiling:
min. h = 80 mm
Connections in plasterboard
86 | SystemairFlex+ Plastic Duct
DN63Flex+HV 18xDN63/160
DN75Flex+HV 12xDN75/160
DN90Flex+HV 6xDN90/160
Art-no. 310252 310978 310980
A 655 745 765
B 420 505 515
C 80 80 80
D 177 145 145
E 175 145 145
Connections 18 + 1x DN160 12 + 1x DN160 6 + 1x DN160
12 connections
18 connections6 connections
DN63Flex+HV 12xDN63/180
DN75Flex+HV 8xDN75/180
DN90
Art-no. 311996 311999 -
A 384 105 105
B 80 70 77,5
C 192 165 165
Connections 12 + 1x DN180 8 + 1x DN180 4 + 1x DN180
8 connections
12 connections4 connections
Flex+ horizontal terminal
Flex+ horizontal terminal
Flex+ horizontal terminal
Horizontal terminal with 9 connections DN63 and 1x DN 160 with oval connection system 151 at the side.
160
105
47 27
300
177
1804545
A
B
D
EC
BBC
C
A
Bezeichnung Art-no.
Flex+HV 9xDN63/160 310250
SystemairFlex+ Plastic Duct | 87
300
150600
B C
A
DN63Flex+VV 18x63/180
DN75Flex+VV 12x75/160
Art-no. 309470 310977
A 180 160B 105 105C 175 205Connections 18 + 1x DN180 12 + 1x DN160
Flex+ vertical terminal
Flex+ horizontal terminal, variable
300
28 48
A
B
DN63Flex+HV 9x63/System 151
DN75Flex+HV 6x75/System 151
DN90Flex+HV 3x90/System 151
Art-no. 304030 311399 311400
A 105 105 105
B 27 70 77,5
Connec-tions
9x DN63 + 1x oval System 151
6x DN75 + 1x oval System 151
3x DN90 + 1x oval System 151
DN75
DN90
DN63
Flex+ horizontal terminal
Customised distributor box Connections can be chosen as required.
Dimensions Code
3x63 6
2x75 7
1x90 9
endcap D
connector K
spigot Ø125 2
spigot Ø150 5
spigot Ø160 6
spigot Ø180 8
endcap D
88 | SystemairFlex+ Plastic Duct
79
229
248
130
128
260
180
149
50 /
70
24
79
250
229
260
92
130
128
Stut
zen-
läng
e
Art-no. Length of column ConnectionsDN63 309463Flex+ US 3x63/125/50
503x DN63 + 1x DN125
DN63 309464Flex+ US 3x63/125/70
70
DN75 310983Flex+ US 3x75/125/50
502x DN75 + 1x DN125
DN75 310984Flex+ US 2x75/125/70
70
DN90 310986Flex+ US 1x90/125/50
501x DN90 + 1x DN125
DN90 310987Flex+ US 1x90/125/70
70
250
92
1 connection
3 connections
108
2 connections
Art-no. Length of column ConnectionsDN63 309465Flex+ US 3x63/125/180
180-230 3x DN63 + 1x DN125
DN75 310982Flex+ US 2x75/125/180
180-230 2x DN75 + 1x DN125
DN90 310985Flex+ US 1x90/125/180
180-230 1x DN90 + 1x DN125
250
92
1 connection
108
2 connections
Flex+ diverter valve connection
Flex+ diverter for plasterboard construction
79
250
229
260
92
130
248
Art-no. ConnectionsDN63 311995Flex+ US 3x63/125 - 13mm flat
3x DN63
Installation example
Wall diverter for lightweight constructions. Inside wall width min. 80 mm. Without inner bridge for stabilisation. Thus, all valves can be inserted. Not to be used for installation in/on the floor.
SystemairFlex+ Plastic Duct | 89
Art-no.DN 50 50 m roll 309462Flex+ FR50DN 63 50 m roll 309461Flex+ FR63 DN 75 50 m roll 310975Flex+ FR75DN 90 50 m roll 310976Flex+ FR90
Name Art-no.DN 50 309468Flex+ RV50DN 63 309467Flex+ RV63DN 75 310991Flex+ RV75DN 90 310992Flex+ RV90
Transition piece from 63 on 50 mm.
Name Art-no.DN 50 / 60 m 310988Flex+ RI 50/60 mDN 63 / 48 m 310989Flex+ RI 63/48 mDN 75 / 40 m 310990Flex+ RI 75/40 m
Flex+ plastic duct, flexible Flex+ duct insulation
Flex+ duct fitting Flex+ transition
Flex+ diverter
Flex+ adapter
For pipe laying under the ceiling or ceiling void installation.
Connection to terminal and diverter is possible. Can be used as a transition from Flex+ to valve.
Flex+ fitting Fitting to connect two terminals, adapter and terminal or terminal and diverter. Use instead of flexible pipe fittings.
Installation example
Art-no. ConnectionsDN63 312503Flex+ US-W 3x63/125
Valve connection DN125
Art-no. ConnectionsDN63 312504Flex+ Adapter 3x63/125 asym.
DN125
Art-no.
Flex+ fitting for components 312505
Terminal and adaptor, mounted
Art-no.Flex+ RED 63/50 309466
90 | SystemairFlex+ Plastic Duct
A
A
Name Art-no. ADN63 - 1 duct 309472Flex+ BS1 90°/1xDN63 153
DN63 - 3 duct 309473Flex+ BS1 90°/3xDN63 153
DN75 - 2 duct 311402Flex+ BS1 90°/2xDN75 189
DN90 - 1 duct 311401Flex+ BS1 90°/1xDN90 226
DN90DN75
Flex+ angle plate 90°
453 270
20
80
85 6
Name Art-no.DN 50 310993Flex+ RS50DN 63 309475Flex+ RS63DN 75 310994Flex+ RS75DN 90 310995Flex+ RS90
Flex+ duct cutter Mounting set for distributor box
Art-no.Flex+ BSV 309474
Accessories ducts, circular
Poly-nail tape
Poly nail tape, width 1.5 cm, roll: 15 m
Duct tape
Screw threadSelf-tapping screw thread
Art-no. packaging unit
59090 SCR4.2/13mm 1000 pcs.
59094 SCR4.2/16mm 1000 pcs.
Art-no.Duct tape Cloth 50mm 57590
Duct tape Foil 50mm 52978
AS401 PVC Tape 38 x 33 White 54212
Art-no.Poly-nail tape 309474
Slotted Banding
Art-no.
57617 25mm x 25m Slotted Band FB-25
Circular Ducts | 91
DN No. ød t L
100 52509 100 0,6 3000
125 52510 125 0,6 3000
160 52512 160 0,6 3000
200 52514 200 0,6 3000
VSP Rigid Spiral Duct
With beadings for reinforcementDuct can be cut to various lengths
36 36
10DN No. ød
100 12062 100
125 200140 125
150 309037 150
160 200817 160
200 200818 200
MF, external connector
ød1
L
L
rm
rm = 1,5xd1
DN No. ød1 L kg
100 12085 100 150 0,6
125 12086 125 190 0,8
160 12087 160 240 1,4
200 12088 200 300 2,1
Length DN 100 DN 125 DN 160 DN 200
0,25 / 0,36 m 12109 12110 12111 12112
0,63 / 1,14 m 12113 12114 12115 12116
Telescopic duct
Bend 90°
The insulating hose is available with 30 mm or 50 mm mineral wool for all sizes.
IS, insulating sleeve
DN Insulation30 mm 50 mm
100 12150 12154
125 12151 12155
160 12152 12156
200 12153 12157
ød
40DN No. ød
100 200820 100
125 200821 125
160 12093 160
200 12094 200
EB, end cap
ød1
L
Lrm
DN No. ød1 L kg
100 12089 100 41 0,3
125 12090 125 52 0,4
160 12091 160 66 0,6
200 12092 200 83 0,9
Bend 45°
Circular ducts, galvanized
92 | Circular Ducts
35 35
5DN No. ød
100 12059 100
125 201348 125
160 12060 160
200 12061 200
ød3
ød1
LL+
70
H
T-piece with reduced outlet / passageDN Art-no. ød1 ød3 H L kg100 12069 100 125 95 215 0,6
125 12067 125 100 75 180 0,7
125 12073 125 160 75 200 0,8160 12065 160 100 92 180 0,8160 12064 160 125 92 180 1,0160 305485 160 150 100 260 0,9200 12074 200 100 112 200 1,1200 12075 200 125 112 250 1,2200 12072 200 160 112 250 1,4
NP, Connector with rubber seal
Connector incl. rubber seal
T-piece with rubber seal
T-pieceDN No. ød1 ød3 H L kg
100 12068 100 100 60 180 0,6
125 12070 125 125 75 200 0,8
160 12063 160 160 92 250 0,9
200 12071 200 200 112 305 1,2
Reducer seal 1
d2
d1
L
d2
d
L
DN Art-no. ød1 ød2 L kg150/125 305038 150 125 140 0,3160/150 305039 160 150 125 0,3250/200 305054 250 200 31 0,6
Reducer seal 2
DN Art-no. ød1 ød2 L kg100/80 12080 100 80 60 0,2125/100 12081 125 100 92 0,3
160/100 12079 160 100 125 0,5
160/125 12078 160 125 110 0,4200/125 12082 200 125 133 0,6200/160 12077 200 160 110 0,5
Reducer seal
øD øA
35
Gasket (only RFP))
RFU No. øD øA kg100 6130 97 120 0,07125 6131 122 146 0,09150 6132 147 170 0,11160 6134 157 180 0,11200 6135 197 220 0,14
RFP No. øD øA kg100 6125 97 120 0,08125 6126 122 146 0,10160 6127 157 180 0,12200 6128 197 220 0,16
RFU and RFP mounting frame are made of galvanized steel sheet. RFP incl. rubber gasket for duct connection.
Mounting frame
ød
L
L1
B
H
DN Art-no. ød L L1 H B125 12178 125 610 315 63 210
160 12179 160 647 315 80 300
Duct cross
Art-no. packaging unit
12456 Frame Ø100 mm
12457 Frame Ø125 mm
12458 Frame Ø160 mm
50780 Frame Ø150mm
50754 Frame Ø200mm
Circular Ducts | 93
Compressed Semi rigid flex with insulation Length / Insulation DN 100 DN 125 DN 160 DN 200IS Insulated 3 m / 25 mm 12125 12126 12127 12128
LFK Acoustic 3 m / 25 mm 12138 12139 12140 12141
IS, Alu-flexible duct
Compressed, double-sided sleeveLength / extract-able length DN 100 DN 125 DN 160 DN 200
230 mm / 1 m 12121 12122 12123 12124
650 mm / 3 m 5631 5632 5633 5634
UIS, Alu-flexible plain duct
Semi-Rigid Flex Duct - 3m Lengths (Semiduct)Description: Semi flexible, high quality, aluminium duct for use in all low / medium pressure systems and suitable for AC. Easy & Fast installation, tough and airtight.Construction: 1 x wound layer of tough corrugated aluminium, “Triple Locked” seams for air tightness & strength. Sizes 100mm to 250mm in 3m lengths
FlexCode
FlexType
Fire safetyTesting
TemperatureRange
Working pressure
100mm - 250mm 300mm - 500mm
Isoduct Thermal BS476 (6.7&20) -30ºC to +140ºC +2.5Kpa to -0.4Kpa +2.5Kpa to -0.2Kpa
Sonoduct Acoustic BS476 (6.7&20) -30ºC to +140ºC +2.5Kpa to -0.4Kpa +2.5Kpa to -0.2Kpa
Semiduct Semirigid BS476 (6.7&20) -30ºC to +250ºC +3.5Kpa to -2.5Kpa +3.5Kpa to -1.5Kpa
FlexCode
FlexType
DiameterClass
Air tightnessClass
Max air velm/s
Crushing strength
Compressed Uncompressed
Isoduct Thermal B C 25 33-10 kg 3-5 kg
Sonoduct Acoustic B C 30 33-10 kg 3-5 kg
Semiduct Semi-rigid A C 30 100-15 kg 60-10 kg
Acoustic / Thermal Flex Duct - 10m Lengths (Sonoduct)Description: Fully flexible, high quality, insulated aluminium laminated duct for use in commercial HVAC systems. Easy & Fast installation over round or oval connections. Tough and airtight with a smooth core for low friction loss and lower operation costs.Construction: Outer vapour barrier is 3 x layers of tough “aluminium / polyester laminates” plus flame retardant adhesive and spiral fibreglass reinforcement. The inner core has 5 x layers of tough aluminium / polyester laminates plus flame retardant adhesive encapsulating a copper plated high tensile steel wire helix.Sizes 100mm to 500mm dia in 10m lengths
Thermally Insulated Flex Duct - 10m Lengths (Isoduct)Description: Fully flexible, high quality, insulated aluminium laminated duct for use in commercial HVAC systems. Easy & Fast installation over round or oval connections. Tough and airtight with a smooth core for low friction loss and lower operation costs.Construction: Outer vapour barrier is 3 x layers of tough “aluminium / polyester laminates” plus flame retardant adhesive and spiral fibreglass reinforcement.The inner core has 5 x layers of tough aluminium / polyester laminates plus flame retardant adhesive encapsulating a copper plated high tensile steel wire helix.Sizes 100mm to 500mm dia in 10m lengths
94 | Flat Ducts
Plastic Flat DuctFlat Duct 1m Length Code Duct Size mm @ 8l/s @ 15l/s @ 30l/s @ 60l/s
System 100 DOM010 51300 110 x 54 0.7 1.8 6.3 21.5
Supertube DOM510 51416 204 x 60 0.2 0.5 1.5 5.2
Megaduct DOM910 51476 220 x 90 - - 0.4 1.0
Pressure Loss (Pa)
Flat Duct 1.5m Length Code Duct Size mm @ 8l/s @ 15l/s @ 30l/s @ 60l/s
System 100 DOM015 51301 110 x 54 1.2 2.7 9.8 32.2
Supertube DOM515 51419 204 x 60 0.3 0.8 2.3 7.8
Megaduct DOM915 51477 220 x 90 - - 1.0 1.4
Flat Duct 2m Length Code Duct Size mm @ 8l/s @ 15l/s @ 30l/s @ 60l/s
System 100 D1-2000 51490 110 x 54 1.5 3.6 12.6 43
Supertube D3-2000 51491 204 x 60 0.4 1.0 3.0 10.4
Megaduct D4-2000 59435 220 x 90 - - 1.5 2.0
Duct Connector Code Duct Size mm @ 8l/s @ 15l/s @ 30l/s @ 60l/s
System 100 DOM020 51303 110 x 54 - 0.3 1.4 6.3
Supertube DOM520 51421 204 x 60 - 0.1 0.4 1.5
Megaduct DOM920 51478 220 x 90 - - - -
Duct Connector c/w Damper Code Duct Size mm @ 8l/s @ 15l/s @ 30l/s @ 60l/s
System 100 DOM027 51304 110 x 54 16.3 19.9 21.2 -
Supertube DOM527 204 x 60 19.6 21.9 41.1 -
Megaduct DOM927 220 x 90 - - - -
Duct Clip Code Duct Size mm @ 8l/s @ 15l/s @ 30l/s @ 60l/s
System 100 DOM122-4 51325 110 x 54 - - - -
Supertube DOM122-5 51326 204 x 60 - - - -
Megaduct DOM922 51479 220 x 90 - - - -
Horizontal Bend 90° Code Duct Size mm @ 8l/s @ 15l/s @ 30l/s @ 60l/s
System 100 DOM050 51307 110 x 54 2.6 9.8 39.8 161.9
Supertube DOM550 51428 204 x 60 0.6 2.1 8.4 33.7
Megaduct DOM950 51482 220 x 90 - - - 9.0
Horizontal Bend 45° Code Duct Size mm @ 8l/s @ 15l/s @ 30l/s @ 60l/s
System 100 DOM055 53880 110 x 54 - 3.7 15.5 65.8
Supertube DOM555 54043 204 x 60 - 0.6 2.7 13.2
Megaduct DOM955 14098 220 x 90 - - - 4.6
Vertical Bend 90° Code Duct Size mm @ 8l/s @ 15l/s @ 30l/s @ 60l/s
System 100 DOM060 51308 110 x 54 4.3 15.6 62.8 252.7
Supertube DOM560 51429 204 x 60 0.7 2.6 10.8 44.3
Megaduct DOM960 51486 220 x 90 - - - 7.0
Vertical Bend 45° Code Duct Size mm @ 8l/s @ 15l/s @ 30l/s @ 60l/s
System 100 DOM075 53881 110 x 54 - 2.6 12.7 63
Supertube DOM575 57570 204 x 60 - 0.6 2.7 13.4
Megaduct DOM975 57705 220 x 90 - - - 6.0
Flat Ducts | 95
Horizontal Tee Piece Code Duct Size mm @ 8l/s @ 15l/s @ 30l/s @ 60l/s
System 100 DOM080 51313 110 x 54 3.5 11.4 51.3 -
Supertube DOM582 51432 204 x 60 0.9 3.1 12.0 26.4
Megaduct DOM982 14194 220 x 90 - - - 12.4
Plastic Flat DuctPressure Loss (Pa)
Duct End Cap Code Duct Size mm @ 8l/s @ 15l/s @ 30l/s @ 60l/s
System 100 DOM018 51302 110 x 54 - - -
Supertube DOM518 51420 204 x 60 - - - -
Wall Plate - White Code Duct Size mm @ 8l/s @ 15l/s @ 30l/s @ 60l/s
System 100 DOM115-4 110 x 54 - - - -
Supertube DOM115-5W 51318 204 x 60 - - - -
Megaduct DOM115-6 220 x 90 - - - -
Fire Wrap Code Duct Size mm
System 100 DOM087 51314 110 x 54
Supertube DOM587 51433 204 x 60
Megaduct DOM987 53375 220 x 90
Flex Duct- White 0.5m Code Duct Size mm
Hose 0.5m DOM3305 110 x 54
Hose 0.5m DOM5305 51422 204 x 60
Hose 0.5m DOM9305 220 x 90
Flex Duct- White 3m Code Duct Size mm
Hose 3m DOM333 110 x 54
Hose 3m DOM533 204 x 60
Hose 3m DOM933 220 x 90
Flex Duct Connector Code Duct Size mm @ 8l/s @ 15l/s @ 30l/s @ 60l/s
System 100 DOM381 110 x 54 - - - -
Supertube DOM581 204 x 60 - - - -
Wall Plate - White Code Duct Size mm @ 8l/s @ 15l/s @ 30l/s @ 60l/s
System 100 DOM040 51306 110 x 54 3.6 8.1 33.1 136.4
Supertube DOM540 51424 204 x 60 2.4 6.6 28.4 -
Megaduct DOM961 51487 220 x 90 - - - 9.0
Itumescent Sealant Code
310ml Tube MAS87
Duct connector - flex Code Duct Size mm @ 8l/s @ 15l/s @ 30l/s @ 60l/s
Supertube 5B303 14193 204 x 60 - - - -
Adjustable bend Horiz Code Duct Size mm @ 8l/s @ 15l/s @ 30l/s @ 60l/s
Supertube DOM545 51427 204 x 60 - 0.7 2.1 6.3
96 | Circ Plastic Ducts
Plastic Round DuctCirc Duct 2m Length Code Duct Size mm @ 8l/s @ 15l/s @ 30l/s @ 60l/s
Easipipe 100 1200-4 51321 100 0.1 1.0 2.8 6.2
Easipipe 125 1200-5 51322 125 - 0.4 1.4 3.8
Easipipe 150 1200-6 51323 150 - 0.2 0.8 2.4
Pressure Loss (Pa)
Duct Connector Code Duct Size mm @ 8l/s @ 15l/s @ 30l/s @ 60l/s
Easipipe 100 DOM493 51401 100 - - - -
Easipipe 125 DOM593 51445 125 - - - -
Easipipe 150 DOM693 51466 150 - - - -
Duct Connector c/w Damper Code Duct Size mm @ 8l/s @ 15l/s @ 30l/s @ 60l/s
Easipipe 100 DOM494 51402 100 15.2 25.0 44.9 101.6
Easipipe 125 DOM594 51446 125 10.2 18.3 31.5 61.7
Easipipe 150 DOM694 51467 150 8.4 13.6 23.5 43.6
Bend 90° Code Duct Size mm @ 8l/s @ 15l/s @ 30l/s @ 60l/s
Easipipe 100 DOM490 51383 100 0.9 5.6 21.1 80.1
Easipipe 125 DOM590 51434 125 0.5 2.0 8.4 34.9
Easipipe 150 DOM690 51453 150 0.3 1.0 4.2 18.2
Bend 45° Code Duct Size mm @ 8l/s @ 15l/s @ 30l/s @ 60l/s
Easipipe 100 DOM491 51399 100 0.3 2.1 8.2 31.4
Easipipe 125 DOM591 51443 125 0.2 0.7 2.9 12.2
Fire Break Code Duct Size mm
Easipipe 100 DOM488 53376 110 x 54
Easipipe 125 DOM588 59554 204 X 60
Easipipe 150 DOM688 220 x 90
Itumescent Sealant Code
310ml Tube MAS87
Tee Piece Code Duct Size mm @ 8l/s @ 15l/s @ 30l/s @ 60l/s
Easipipe 100 DOM492 51400 100 0.7 2.3 8.5 -
Easipipe 125 DOM592 51444 125 0.5 1.8 4.4 -
Condensate Trap Code Duct Size mm @ 8l/s @ 15l/s @ 30l/s @ 60l/s
Easipipe 100 DOM497 51404 100 0.3 1.3 5.9 26.9
Easipipe 125 DOM5697 59433 125 0.3 1.3 5.7 25.0
Easipipe 150 DOM5697 59433 150 0.3 1.3 5.7 25.0
Duct Clip Code Duct Size mm @ 8l/s @ 15l/s @ 30l/s @ 60l/s
Easipipe 100 DOM496 51403 100 - - - -
Easipipe 125 DOM596 51447 125 - - - -
Easipipe 150 DOM696 51469 150 - - - -
Reducer Code Duct Size mm @ 8l/s @ 15l/s @ 30l/s @ 60l/s
125 - 100 40119 125 - 100 0.6 1.5 5.9 24.0
150 - 125 50118 150 - 125 0.4 0.6 2.2 8.8
150 - 100 150 - 100 0.4 1.0 3.8 10.0
Flat Ducts | 97
Plastic Adapters
Duct Adapters long Code Duct Size mm Duct Size @ 15l/s @ 30l/s @ 60l/s
Easipipe 100 DOM490 51383 110 x 54 100mm 3.7 14.6 58.0
Duct Adapter Short Code Duct Size mm Duct Size @ 15l/s @ 30l/s @ 60l/s
Easipipe 100 DD071 51310 110 x 54 100mm 4.8 20.4 86.2
Duct Adapter Code Duct Size mm Duct Size @ 15l/s @ 30l/s @ 60l/s
Easipipe 125 DD073 51311 204 x 60 100mm 4.1 16.8 68.7
Easipipe 125 DOM570 51430 204 x 60 125mm 0.7 2.9 11.5
Easipipe 150 DOM970 51488 220 x 90 150mm - - 3.7
98 | Flat Ducts
Rigid, oval installation ducts, smooth interior for air flow, made of galvanized steel band. Fire protection class A1 according to DIN 4102. Temperature resistance: up to +200 °C, length: 3 m
Internal dimension:
System 100 305045 129 x 52
System 151 305046 208 x 52
Quadrofix - smooth interior
Dimensions, inside: Length
System 100 305043 129 x 52 3 m
System 100 305047 129 x 52 15 m / roll
System 151 305044 208 x 52 3 m
Corrugated, folded spiral seam pipe made of galvanized steel band for higher vertex pressure resistance. Fire protection class A1 according to DIN 4102.Temperature resistance: up to +200 °C, length: 3 m
Quadroflex - corrugated
Inside connector, stainless steel, to con-nect two Quadroflex or Quadrofix pipes.
85Dimensions:
System 100 305007 128 x 51
System 151 305008 207 x 51
Inside connector - tight/tight
External connector, stainless steel, to con-nect two Quadroflex or Quadrofix pipes.
Dimensions:
System 100 (305064) 129 x 52
System 151 (305009) 208 x 52
External connector - large/large
Flange collar, stainless steel, for Quadro-flex or Quadrofix pipes.
6 to
10
Dimensions: System 100 305010 128 x 51
System 151 305011 207 x 51
Flange collar
ø1 m
0,5
m
Internal dimension:
System 100 305047 129 x 52
Corrugated, folded spiral seam pipe made of galvanized steel band for higher vertex pressure resistance. Fire protection class A1 according to DIN 4102. Temperature resistance: up to +200 °C, length: 15 m
Quadroflex - corrugated in a bunch
Duct cover, stainless steel, for Quadroflex or Quadrofix pipes
6 to
10
Dimensions:
System 100 305055 128 x 51
System 151 305056 207 x 51
Duct cover
Flat ducts, oval, metalsheet
Flat Ducts | 99
Angle 45° (broadsided), made of galva-nized steel to bypass Quadroflex or Quad-rofix pipes, when little space.
Angle 45° (narrow sided), stainless steel, to bypass Quadroflex or Quadrofix pipes, when little space.
Angle 45° - broadsided
External dimensions
System 100 305027 128 x 51
System 151 305028 207 x 51
Angle 45° - narrow sided
External dimensions
System 100 305029 128 x 51
System 151 305030 207 x 51
External dimensions
System 100 305031 128 x 51
System 151 305032 207 x 51
Angle 90° (narrow sided), stainless steel, in 3 segments to bypass Quadroflex or Quadrofix pipes.
Angle 90° - broadsided, 3 segments
Angle 90° (broadsided), stainless steel, in 3 segments to bypass Quadroflex or Quadrofix pipes.
Angle 90° - narrow sided, 3 segments
External dimensions
System 100 305033 128 x 51
System 151 305034 207 x 51
Branch piece 90°, stainless steel, 3 connection spigots for Quadroflex or Quadro-fix pipes.
Branch piece 90°, stainless steel, 3 connection spigots for Quadroflex or Quadro-fix pipes.
Dimensions:
System No. Passage Outlet Length
100-100 305013 128 x 51 128 x 51 300
100-151 305014 128 x 51 207 x 51 360
151-100 305015 207 x 51 128 x 51 300
151-151 305040 207 x 51 207 x 51 360
Dimensions:
System No. Durchgang Abgang Length
151-100 305016 207 x 51 128 x 51 220
151-151 305048 207 x 51 207 x 51 240
Branch piece - output narrow sidedBranch piece - output broadsided
100 | Flat Ducts
PVC diverter to connect air passages.
Dimensions Art-no.
System 100 / DN100 311240
System 100 / DN125 311241
System DN151/150 305426*
Diverter, PVC
Dimensions Art-no.
System 151-100 207 x 51 auf 128 x 51 305022
Section reducer, stainless steel, for Quadroflex or Quadrofix pipes
Reducer - flat to flat
Branch piece - output system 151
Dimensions
Passage Art-no.
ø150 305017
ø200 303177
Branch piece 90°, stainless steel, 1 connection spigot for Quadroflex or Quadrofix pipes system 151.
Dimensions
System Art-no. from to
100 305018 128x51 ø99
151 305019 207x51 ø150
Transition, symmetric, stainless steel, to adapt oval pipe ends to round sections.
Transition - round to flat
* Stainless steel
Diverter 90° to connect disc valves.Material: Stainless steel
Angle diverter for disc valve
Cold sealing tapeDimensions Art-no. HSystem 100/DN100 303052 185,5
System 100/DN125 303053 210,5
Art-no.Cold sealing tape 305001
Cutting max. 300 mm!
Circ Insulated Ducts | 101
ISO+ duct, sound and thermal insula-tion
Typ External-ø Internal-ø Art-no. Length
Iso+ D 160-125 160 125 311838 2 m
Iso+ D 200-180 200 180 311844 2 m
ISO+ bend 90°
Noise-absorbing, sturdy duct, preferably in unheated areas.Outer sheath made of polyethylene with high density (HDPE); inner sheath made of polyolefin with closed cell structure.Thermal conductivity: 0.040 W/mK at 40 °C.Fire protection class: Outer casing B2, in-ternal duct B1
ISO+ bend 45°
Typ DN Art-no.
ISO+ B90/160-125 125 311839incl. 1 connector
ISO+ B90/200-180 180 311845
Typ DN Art-no.
ISO+ B45/160-125 125 311840incl. 1 connector
ISO+ B45/200-180 180 311846
ISO+ connector
Typ External-ø Internal-ø Art-no.
ISO+ C 160-160 160 125 311841
ISO+ C 200-200 200 180 311847
Flexible fast clamp made of EPDM.
ISO+ transition to Spiral, symmetric
Typ External-ø Internal-ø Art-no.
ISO+ R 160-125 160 125 311842
ISO+ R 200-180 200 180 311848
ISO+ R 200-160 200 150/160 311849
ISO+ transition to Spiral, asymmetric
Typ External -ø Internal-ø Art-no.
ISO+ R 160-125A 160 125 311843
ISO+ R 200-180* 200 150 311848
Material: EPDM
Material: EPDM
ISO+ FSMQC Quick clamp
Type Dia for Spiral duct Art-no.
60mm-165mm 160 51624
60mm-215mm 200 51625
To fix rubber collars for Spiral duct.* for Spiral160
ISO+ ducts
102 | Silencer
SilencerPerforated aluminium flex pipe inside, PVC cover outside Sound insulation made of 25 mm mineral wool. Connection sleeve on one side, connection fitting on the other side.Length: 800 mm
DN Art-no. Connecting sleeve
100 12436 ø100
125 12533 ø125
Insertion losses in dBOctave centre frequency in Hz
DN 125 250 500 1k 2k 4k 8k tot
100 8 14 22 30 25 10 8 15
125 6 12 22 28 25 11 9 14
LF, connection silencer, flexible
SCD, silencer, flexible
Art-no. Name D (mm) L (m)Mid frequency band. Hz
63 125 250 500 1000 2000 4000 8000 Tot (dB)
2554 SCD 80 80 1.2 13.6 22.4 40.2 38.7 36.5 41.3 51.6 45.8 39
2555 SCD 100 100 1.2 15.9 22.9 31.1 38.6 36.4 40.6 50.1 35.9 39
2556 SCD 125 125 1.2 11.7 18.9 32.4 29.9 28.8 34.5 40.9 24.5 32
2557 SCD 150 150 1.2 12.2 10.9 29.7 30.1 29 38.3 34.6 20.4 32
2558 SCD 160 160 1.2 19.3 25.4 30.5 27.1 23.8 32.2 27.8 17.3 28
2560 SCD 200 200 1.2 10.7 12.1 28.7 22.8 22.8 30.6 19.4 11.9 26
2561 SCD 250 250 1.2 12.9 18.7 24.3 19.5 19.9 27.7 12.9 10.2 22
2562 SCD 315 315 1.2 16.6 23.2 18 15.2 16.5 19.6 10.1 8.5 17
Noise reduction, non-woven insulation 25 mm
The internal duct consists of a closed, non-woven internal hose (washable) and an insulation layer made of glass wool with a thickness of 25 mm and sound reducing and thermal effective properties. The outer casing is made of glass-fibre reinforced, tear-resistant aluminium laminate. Fire classification outercasing: Ex.1. Length: 1,2 m
LDC, silencer, rigid Easily-fitted silencer for circular ducts, fitted with a connection that complies with the spiral duct standard. The LDC effectively reduces noise in the duct. For the most ef-fective noise reduction, the silencer should be fitted immediately behind a fan or bend. The silencer is delivered with two separate spigots. Insulation thickness 100 mm.
Art-No 600mm L Art-No 900mm L
5188 LDC 100-600 5189 LDC 100-900
5190 LDC 125-600 5191 LDC 125-900
5199 LDC 150-600 - -
5192 LDC 160-600 5193 LDC 160-900
5194 LDC 200-600 5195 LDC 200-900
51200 LDC250-600 5196 LDC 250-900
5949 LDC315-600 5197 LDC 315-900
TSD, semi rigid silencer, flexible Art-No 1000 mm L
54144 TSD-B100/1 Flex Silencer
54145 TSD-B125/1 Flex Silencer
54146 TSD-B150/1 Flex Silencer
54147 TSD-B200/1 Flex Silencer
54148 TSD-B250/1 Flex Silencer
54149 TSD-B315/1 Flex Silencer
The semi flexible sound attenuator consists of a corrugated perforated aluminium inner-duct and a 2 layer corrugated outerduct with end spigots made of aluminium. The spacebetween the inner and outer duct is filled with 50mm sound absorbing material.
Silencer | 103
Perforated aluminium flex pipe inside, PVC cover outsideSound insulation made of 25 mm mineral wool. Length: 1 m
DN Art-no. Connecting sleeve100 12491 ø100
125 12492 ø125
160 12493 ø160
200 12494 ø200
Insertion losses in dBOctave centre frequency in Hz
DN 125 250 500 1k 2k 4k 8k tot
100 15 31 31 32 29 13 11 24
125 26 36 30 31 28 14 11 24
160 17 31 25 27 18 8 8 19
200 15 29 22 23 18 8 7 18
Duct Silencer, flexible
Silencer for noise reduction Oval duct connection made of alu-minium. Absorption material: mineral fibre-free.Fire protection class A1 according to DIN 4102.Temperature resistance from -60 °C to +150 °C
Insertion losses in dBOctave centre frequency in Hz
System 125 250 500 1k 2k 4k 8k tot
100 8 10 18 46 50 44 38 15
Length Art-no. Dimensionsinside
Dimensions outside
End connec-tions
500 305012 129 x 52 202x117 128 x 51
Flat duct Silencer, flexible
Mineral fibre-free silencer in combination with Quadro Sys-tem 100.Fire protection class A1 according to DIN 4102.Temperature resistance: up to +200 °C
Insertion losses in dBOctave centre frequency in Hz
DN 125 250 500 1k 2k 4k 8k tot
100 18 14 13 11 19 18 17 13Length Art-no. Dimensions End connections
500 305036 360 x 60 128 x 51
Flat duct Silencer, rigid
360
System 10060
500 58,5
d1 Insertion losses in dBOctave centre frequency in Hz
DN 125 250 500 1k 2k 4k 8k tot
100 14 12 8 7 7 11 18 8
125 14 9 5 8 6 11 16 7
160 14 9 8 7 7 14 17 8
200 12 4 4 8 8 13 14 6
DN Art-no. d s100 305049 102 50125 305050 127 50160 305051 162 50200 305193 202 50
Inside duct silencer, made of fire and mould protected foam ma-terial according to the requirements of emission class M1 (mela-mine resin). Complete valve function for sound insulation and pressure control.
Inside duct silencer
s = IRS Stärke
104 | ISO+ Ducts
Kombi grille for separate flow of fresh and exhaust air. Made of coated steel sheet, colour anthracite. Sizes 160/200 are also available in colour white.
E
øD
A
B
C
CVVX blackArt-no.
whiteArt-no. A B C øD E
160 5563 12453 420 362 215 160 130
200 5564 12593 500 402 255 200 133
250 8498 - 680 550 350 250 136
Fresh and exhaust air grille, made of aluminium pressure die casting with wire grille.
D
d
IGC Art-no. ød øD
100 5581 100 125
125 5582 125 150
160 5583 160 185
200 5584 200 225
250 5585 250 275
The hood can be used for fresh or exhaust air. Made of galva-nized steel sheet.The internal protective grille protects from rain, leaves etc.
15°
ød1
h
øD
H
Fresh and exhaust air hood
DN Art-no. ød1 øD h H kg
200 305042 200 360 100 197 1,9
Kombi grille CVVX
Fresh and exhaust air grille IGC
Roof ventilation hood for fresh and exhaust air
DN Art-no. ød1 ød2 L L1 L2 L3125 6788 210 125 830 480 350 130
160 6789 180 420 820 260 158 178
200 67893 on request
Roof ventilation hood with pipe bracket. Other roof pitchs on request.
Fresh and exhaust air grille
Terminals | 105
VK-SR, air grill for spiro ducts
Fresh air and exhaust air grill. The duct connection fits directly into duct with diameter 160, 200 and 250. Material: steel, powder coated (black)
A
BCF
ED
G
Size No. A B C D E øF G160 312507 326 306 280 149 137 160 33°
200 312508 326 306 280 149 137 200 33°
250 312509 326 306 280 149 137 250 33°
ISO+ grille
Size Art-no. A B C D E øF GISO+ grille 125 312506 252 262 239 130 on request 125 35°ISO+ grille 180 304635 252 262 239 130 41 180 35°
øF
ED
G
A
BC
Fresh air and exhaust air grille. The duct connection fits directly into ISO+ duct with diameter 125 (Iso+ D160) or 180 mm (Iso+ D200).Material: steel, powder coated (black)
External Weather Louvre
Made of mirror-bright stainless steel, for outside and extract air, with bird-protection grille.
20070
45°270
Universal Roof cowl, complete with lead flashing and multi cut off spigot 100mm, 110mm, 125mm, 150mm & 160mm Dia cut offs
DN Art-no.EFS-RCK 53842-
DN Art-no. Connection
150 305035 ø150
200 - ø200
Inlet-/blow-out nozzle
Universal Roof Cowl
Ideal for use on the external walls of a building for intake or extract air, the 45 deg blades are fixed at 50mm centres and have excellent integral rain defence features. Constructed from extruded aluminium sections, frames are fully welded and fitted with a bird guard as standard. Standard finish is satin anodised. with other colours available on request. Free area approx 50%. Any size can be made to suit your require-ments.
106 | Diffusers
DescriptionSystemair Elegant supply diffuser for wall mounting, with a perforated front plate and guide jet opening (VI and VS). The VS version also has a removable damper with test points.
FunctionThe Elegant has been especially developed for providing a draught-free air supply from the rear walls of offices, hotel rooms etc. The VI or VS version with guide jet is recommended for cooled air. The guide jet prevents the air stream from fall-ing into the occupied zone before it has reached an acceptable temperature. Max. temperature difference dT 10 K is permis-sible. The Elegant is also suitable for VAV systems, as the distribution pattern is maintained across the entire flow area.
DesignThe Elegant is manufactured from steel
VTVS
VI, VS
AT, VEB
DC
VT
Elegant AT VE VI VS VT100 125 100 125 160 125 160 125 160 100 125
Art-No. 6920 6973 6298 6827 6828 6829 6830 6831 6832 6202 6207Max. air volume [m³/h]
30 60 30 60 140 70 150 60 140 30 60
øA 98 123 98 123 158 123 158 123 158 - -øB 165 165 165 165 198 165 198 165 198 165 165C 111 115 111 115 124 115 124 240 274 59,3 59,3D 87 89 87 89 86 89 86 214 236 33,2 33,2
and consists of a convex front plate with perforations and guide jet opening. The front plate is finished in the standard white powdercoating (RAL 9010-80).
AT
106 |
Elegant - Supply diffuser
Diffusers
DescriptionSystemair EFF exhaust diffuser for installation on ceiling or wall with lockable settings. FunctionThe EFF is an exhaust diffuser for installation on ceiling or wall. It can also
EFFCeiling- and wall diffuser
be used for supply air. The diffuser has a lockable central cone which is rotated to adjust the pressure and consequently the air volume. Fire Rated Versions available.
EFF 100 125 150 160Art-No. 6146 6147 7490 6148Max. air volume [m³/h]
20 50 100 100
øA 100 125 149 159øB 135 160 191 196C 15 15 15 15
DesignThe EFF is manufactured from sheet steel with a white powder-coated finish (RAL 9010-80).
Diffusers | 107
valve cone. The Balance-S performs ex-tremely well with regard to sound level, pressure drop, air flow and self-damping. The Balance-S is installed in a frame or directly into the duct.
DescriptionSystemair Balance-S supply diffuser for in-stallation on ceiling or wall.
FunctionThe Balance-S is a round supply-air dif-fuser with an aerodynamically shaped
frame
Balance-S Plastic Supply diffuser Balance-S 100 125 160
Art-No. 6965 6966 6967Max. air volume [m³/h]
20 50 100
øA 100 125 160øB 81 104 120øC 156 182 206D 72 78 86
DesignThe Balance-S is manufactured from re-cyclable polypropylene and tolerates tem-peratures up to 100°C. The Balance-S is supplied in a white finish which matches RAL 9010.
Stainless Steel Air Valves
FSSSVLF 100 150 160Art-No. 51634 53981 51635Max. air volume [m³/h] 20 100 100
DescriptionSystemair Balance-E exhaust diffuser for installation on ceiling or wall with lock-able settings.
FunctionThe Balance-E is a round exhaust diffuser with an aerodynamically shaped valve
frame
cone. The Balance-E performs extremely well with regard to sound level, pressure drop and air flow characteristics. The Bal-ance-E is installed in a frame or directly into the duct.
Balance-E Plastic Extract diffuser
Balance-E 100 125 160Art-No. 6961 6962 6963Max. air volume [m³/h]
20 50 100
øA 100 125 160øB 70 87 118øC 142 160 195D 61 61 57
DesignThe Balance-E is manufactured from recyclable polypropylene and tolerates temperatures up to 100°C. This material also withstands most chemicals in small concentrations. Polyether packing. The Balance-E is supplied in a white finish which matches RAL 9010-80.
DescriptionSystemair FSSSVLF exhaust diffuser for installation on ceiling or wall with lockable settings.
FunctionThe EFF is an exhaust diffuser for installation on ceiling or wall. It can also be used for supply air. The diffuser has a lockable central cone which is rotated to adjust the pressure and consequently the air volume.
DesignThe FSSSVLF is manufactured from stainless steel with a brushed finish
108 | Diffusers
BOREADescriptionThe Borea valve is adjustable and can be used for supply and exhaust air. The valve can be installed in ceilings and walls.
FunctionThe outlet can be partly closed for an individual regulation of supply air flow.
DesignBorea is completely made of polystyrene. It consists of a main casting, a plate closer and adjustable front grid. Therefore, different flow forms and routes can easily be adjusted.They can be inserted into DN125 pipes or DN125 flange collars.
DescriptionThe Systemair TST circular supply diffus-er. The distribution pattern can be altered and the gap width is adjustable.
FunctionThe TST is a circular supply diffuser for ceiling installation. The two-part diffuser unit can be adjusted to provide the de-sired throw. A shielding device is included which can be used to alter the distribution pattern to a directional (180°) pattern.
DesignThe TST is manufactured from galvanized sheet metal, with a white powder-coated finish (RAL 9010-80).
TST Supply diffuser
TST 100 125+
PER 100-125160+PER 125-160
Art-No. 6105 6106 6107Max. air volume [m³/h]
30 60 140
A - 320 360B - 250 250C - 150 160D - 47 47E - 185 210F - 116 121G - 191 201H 30-50 30-50 30-50RI 80 105 105J 199 249 249K 99 124 159D1 - 99 124D2 - 127 162øL* 107 132 167
* hole dim.
DescriptionThe Systemair TFF circular supply diffus-er. This diffuser has a shielding device for producing a directional (180°) distribu-tion pattern and has an adjustable gap.
FunctionThe TFF is a circular supply diffuser for ceiling installation. The TFF consists of
TFF Ceiling and wall diffuser TFF 100 125 150 160
Art-No. 6090 6091 7509 6092Max. air volume [m³/h] 20 50 100 100
øA 100 125 149 159øB 135 160 191 196C 15 15 15 15
an inlet cone and diffuser unit containing sound-absorbent material. The technical specifications of the diffuser unit give it a wide range of applications. By rotating diffuser unit, the throw and pressure drop can be adjusted steplessly. Both concen-tric and eccentric distribution patterns can be selected by using the shielding
device provided.
DesignThe TFF is manufactured from sheet steel with a white powder-coated finish (RAL 9010-80).
Self regulating extract air valves | 109
BOREA settings
Supply airGrid open/plate closed Grid closed/plate in position 1
without shieldingGrid closed/plate in position 2 with or without shielding
Exhaust airGrid open/plate in position 2 without shielding
Grid closed/plate in position 1 without shielding
Grid closed/plate in position 2 without shielding
The plate inlet can be partly closed by deflectors to shield some areas. Deflec-tors can be removed for exhaust or 4-sided outlet.
Dimensions
BOREA Art-no. ØD1 ØD1 Hmin. Hmax.
125 - 119 165 12 24
ØD2
ØD1
Hmin. Hmax.
+
-
+-
Deflectors
Open (+) and closed (-) valve plate (position closed, 1 and 2)
Open (+) and closed (-) grid
Type Air volumeQv[m³/h]
Supply air Exhaust air
Grid open, Valve closed
without deflector with deflector Grid open, Valve open
Grid closed, Valve openGrid closed, valve open
Position 1 Position 2 Position 2 Position 2 Position 1 Position 2
dB (Pa)
Lw (dB(A)
dB (Pa)
Lw (dB(A)
dB (Pa)
Lw (dB(A)
dB (Pa)
Lw (dB(A)
dB (Pa)
Lw (dB(A)
dB (Pa)
Lw (dB(A)
dB (Pa)
Lw (dB(A)
BOREA125
45 9 < 20 18 26 7 < 20 13 22 3 < 20 20 23 7 < 20
60 17 < 20 30 31 13 21 20 27 5 < 20 37 33 13 21
75 25 24 40 35 18 24 31 32 8 < 20 57 41 20 25
90 36 31 56 39 25 28 43 36 11 20 80 46 27 29
120 62 43 - - 40 36 70 43 19 28 - - 48 36
150 - - - - 62 41 - - 28 34 - - 74 43
Technical data
110 | Self regulating extract air valves
Self regulating extract air valvesAE Self regulating motorized valve
1. Removable louver grill2. Casing vent3. Support plate with sleeve and rubber ring4. Control module5. Electric connection box
FunctionIntended to equip the facilities hous-ing MEV, housing and local service, the range of the AE extraction air valves self meets the regulatory requirements while combining aesthetics and technology. Reliability mechanical, proven function-ality, performance ventilation and noise are the major assets of all AE air valves series. The AE air valves meets the habi-tat requirements of the NF MEV. Single or double speed, both models perfectly consistent allow a uniform architectural treatment between kitchen, bathroom and WC.
ModelProduced in white polystyrene (stand-ard), the AE air valve, installed in WC room and baths, provides a flow of extrac-tion determined.
OperationThe regulator consists of a rigid compo-nent and ensures a determined air flow of extraction within a range of pressure between 50 and 160 Pascals.
PrincipalsThe extract is always on tension thanks to a connection normally switched off.An impulse on the switch creates a power cut which opens the extract to its maximum-flow (opening time: around 40 seconds).The 230 V supply of the extract is pro-vided by two wires (2 x 1.5 mm²) to be connected,going out by the back of the support plate (see drawing). This must have a protectiondevice clearly identi-fied on the electric board - class II electric appliance -.After taking out the casing vent (2), unscrew the box (5). The wires go through a cableat the back of the
1
2
5
3
4
200
150
100
50
040 60 80 100 120 140 160 Pa
120
6045
3015
∆pt
Airf
low
in m
³/h
275
Ø12
5
plastic sleeve for penetrating slabs
three-claw plasterboard sleeve Ø 125
155
Ø125
100
return angle guide
Ø12
548
17
AE No.
15/30 31412
30/60 31413
45/120 31414
plate and linked to the connection box.The support-plate of the extract must be screwed on the wall.On the first stand-by mode, the AE valve will normally extract the maximum air-flow.
MaintenanceThe Extract AE must be periodically cleaned (at least twice a year) in order to keep their entire efficiency. Cleaning pro-cedure:•Removethecasingvent(2)oftheplate(3)andremovetheflap(4).•Theplate (3) linked to the duct must not be touched. The elements on it do not need anycleaning.•Cleanthecasingvent(2),the grill (1) and the control module (4)withsoapywaterthenrince.•Fixbackthecontrolmomule(4)•Fixbackthecasingpart (2) on the plate (3)
Ceiling mountingCeiling mounting, the unit can be fixed on the ceiling using a three-claw plas-terboard sleeve or a 125 Ø plastic sleeve for penetrating slabs. A ceiling mounting needs the using of a return angle guide for the concerned models.
Acoustic characteristics
LW dB(A)
AE 70 Pa 100 Pa 130 Pa 160 Pa
15/30 24 27 30 33
30/60 25 31 34 36
45/120 27 33 34 37
Self regulating extract air valves | 111
AL Self regulating valve
FunctionIntended to equip the facilities housing MEV, housing and local service, the range of the AL extraction air valves self meets the regulatory requirements while com-bining aesthetics and technology. Design fluid grid in several colors, reliability me-chanical, proven functionality, perfor-mance ventilation and noise are the major assets of all AL air valves series. The AL air valves meets the residential require-ments of the NF MEV. Single or double speed, both models perfectly consistent allow a uniform architectural treatment between kitchen, bathroom and WC.
ModelProduced in white polystyrene(standard), the AL air valve, installed in WC room and baths, provides a flow of extraction determined.
OperationThe regulator consists of a rigid compo-nent and ensures a determined air flow
Ventilation characteristics
Pressure drop in PA
Airf
low
in m
³/h
AL
1. Collar Ø 125 with lip seal (delivered separately).
2. Body of the valve.3. Regulator.4. Removable grille.
Slab penetration sleeve (Polystyrene)
275
Ø12
5
3-Claw plasterboard sleeve
155
Ø125
100
of extraction within a range of pressure between 50 and 160 Pascals.
MaintenanceTo maintain maximum efficiency, it is necessary to conduct a periodic cleaning:
• Remove the grille (4) and regulator (3) the body of the valve (removed from the sleeve if necessary).
• The sleeve (1) shall not be detached from the duct.
• Clean all either in the upper part of a dishwasher, either manually with soap and water, nothing disassemble the regulator.
• Walk up the valve.
InstallationThe AL is installed in vertical walls by simple fitting onto a 125 Ø sleeve fixed on the aeration duct. The lip seal ensures that the sleeve is securely fixed and watertight.
AL Art-No.
15 35028
30 35029
45 35030
60 35031
75 35032
90 35033
120 35034
150 35035
Acoustic characteristics
LW dB(A)
AL 70 Pa 100 Pa 130 Pa 160 Pa
15 m³/h 19 27 31 34
30 m³/h 27 30 33 36
45 m³/h 27 33 34 37
Possible fitting with Ø 99, 116, 150 or 160 mm. When ceiling mounted, an adapted sleeve can be used (125 Ø, 3-claw plaster-board sleeve, or 125 Ø plastic sleeve for penetrating slabs for use with the 125 Ø sleeve).
112 | Self regulating extract air valves
BHC Motorized valve
Type Art-No.
BHC-100 7178
Transformer-12 V 7387
Inlet adapter ø100-125 7484
Airflow in m³/h @ 100 Pa
Relative humidity in %
BHC h..(airflow <<+>> at min. setting)BHC h..(airflow <<+>> at max. setting)
Data given on 100 mm
FunctionBHC 100 is a motorized damper with in-tegrated motion (PIR) and humidity sen-sor for bathroom installations. The extract units may be installed either on the wall (in a vertical or horizontal position), or the ceiling. The humidity and the motion sensors work independently of each other. The damper opens whenever motion is indicated and closes 25 min after the last indication. The humidity sensor controls the fully modulating damper from RH 30% to 75%. The movement sensor is de-pendent on a power supply and the BHC uses either a 9V battery or 12V AC. The humidity sensors will open the damper regardless of a power supply.
Spigot VersionsØ100 mm and Ø125 mm (with adapter).
More Standard and better longevity:2 x 1.5 Volts AAA LR03 Batteries.
Buzzer:Enables to inform the occupant when the battery needs to be replaced (i.e. when the battery level is below 2.2V). This buzzer rings when the presence sensor or the switch is activated.
Possibility to connect a dedicated “CAL” for 12VAC supply.
Airf
low
in m
³/h
Measured pressure in Pa
Nom
inal
pre
ssur
e in
Pa
4625
33
16
174
169
Ø80 mm (with special sleeve Ø80 mm). note: the BPD is delivered with adapter Ø100 mm. The BPD dampers are espe-cially useful in constant pressure systems for example block of flats.
Accessories100/125 inlet adapter and 12/9 v trans-former.
Airflow/Pressure ChartEnables to adapt the fixed shutter posi-tion. Supplied on installation instruction)
Self regulating fresh air valves | 113
FAV sound insulated wall diffuser
The FAV wall diffuser impresses with its design and outstanding sound insulation properties. The new designed intake valve is suitable for normal and high sound insulation requirements by its excellent functions and air distribution character-istics. All necessary components for the installation are available as a complete package.
Application / installation possibilitiesFor installation in facades as wall dif-fuser for fresh air supply in single-family houses, office buildings and multi-storey residential buildings. The wall diffuser is particularly suitable in living rooms and bedrooms.
[ Hz ]
90
80
70
60
50
40
30
50 80 125
315
500
800
1250
2000
3150
5000
200
Referenz
[ dB
]
FAV
Type Art-No. øBore(core drill)
max. air volumewith standard filter G3
Noise level Dn.w *wall thickness
Rw, R ** Version/Colour ***
FAV 312214 (set) 125 mm(132 mm) 10 Pa 30 m³/h 400 mm / 48 dB
500 mm / 51 dB18 dB20 dB PVC, square, white
* Weighted element standardised sound level difference Dn.w according to DIN EN ISO 140-10
** Sound insulation value according to DIN 4109
*** Colour white: similar to RAL 9010
FunctionUsed air from kitchens, bathrooms, lumber-rooms and toilet rooms is exhausted via an exhaust system. Fresh air is filtered by the FAV and well distributed into living rooms, bedrooms, children rooms and lounges. Stepless adjustable volume flow via iris damper. An optimal efficiency can be achieved by an instal-lation position on the upper wall next to windows, in a height of 2.0-2.2 m above a radiator. A storm protection limits supply air to 30 m³/h and avoids draught.
Self regulating fresh air valves
supply diffuser outside grille
wall spacer sound insulatedwith storm protection
114 | Self regulating fresh air valves
VTK Self-adjusting fresh air vent
D
14
0
A C
B150
This self-adjusting fresh air vent has a temperature-sensitive thermostat bulb which regulates the vent plate, adjust-ing the air gap and air flow according to the outside temperature. When it is set to ‘automatic’ the valve disc reduces the air supply when the outside temperature falls, and increases the flow when the out-side temperature rises.
VTK 100 160
Art-no. 5658 5659
øA 95 157
B 40 47
øC 147 207
øD 104 163
Spacers for maintaining minimum air flow are available as an accessory. Sup-plied complete with a thermostat bulb for temperatures between -5 and +10°C, plus a wall duct and external grille.
Accessories FAV
Outdoor grille Raincover for outdoor grille
Filter cartridge F7Standard filter mat
Art-no. Colour
Outdoor grille 312217 white, RAL 9010
Art-no. Colour
Raincover 312216 white, RAL 9010
Art-no.
Standard filter 312218
Art-no. Length
Filter F7 312215 94 mm
Constant flow Regulators | 115
Air volume controllerRDA Constant volume damper
FunctionThe air flow regulator RDA is an element placed inside the duct in order to obtain a constant flow within a pressure range from 50 to 200 Pascal. It is used in venti-lation or air conditioning systems for sup-ply or return air. The air is forced to pass through predetermined space in which a flap can change the position according to the specified air flow. The flap is attached on to a calibrated spring and therefore no auxiliary power is needed.
DesignRDA is made from plastic material (poly-styrene) classified M1 in grey colour. Maximum temperature is 60°C.
MountingRDA is inserted directly into a horizon-tal or vertical circular duct. It is fixed and kept airtight by a lip seal. Arrow indicates the airflow. If the unit is placed in supply duct, the space between the diffuser and the unit must be at least 3x diameter of the duct. If used for return air the space must be 1x diameter of the duct.
*spacer = special body without spacers1* air flow = special shims with air flow ref.
spacer
RDA Art-No. 80 /15 (m³/h) 35259
80 / 30 (m³/h) 35260
80 / 45 (m³/h) 35261
80 / 50 (m³/h) 35262
80 / 60 (m³/h) 35263
100 / 15 (m³/h) 35265
100 / 30 (m³/h) 35266
100 / 45 (m³/h) 35267
100 / 50 (m³/h) 35268
100 / 60 (m³/h) 35269
100 / 75 (m³/h) 35270
100 / 90 (m³/h) 35271
100 / 100 (m³/h) 35272
125 / 15 (m³/h) 35274
125 / 180 (m³/h) 35280
125 / 30 (m³/h) 35275
125 / 45 (m³/h) 35276
125 / 50 (m³/h) 35277
125 / 60 (m³/h) 35214
125 / 75 (m³/h) 35213
125 / 90 (m³/h) 35212
125 / 100 (m³/h) 35278
125 / 120 (m³/h) 35211
125 / 150 (m³/h) 35279
Airflow LW dB(A)(m³/h) 50Pa 100Pa 150Pa 200Pa15 25 29 32 3530 26 31 35 3845 27 33 36 3960 32 37 39 4275 32 37 40 4290 32 38 41 44120 30 34 39 42150 33 37 41 45180 34 40 44 47210 34 40 42 44240 35 41 44 47270 37 43 45 49300 33 37 42 45
Flow(m³/h)
Lw in dB(A)50 Pa 100 Pa 150 Pa 200 Pa
15 25 29 32 3530 26 31 35 3845 27 33 36 3960 32 37 39 4275 32 37 40 4290 32 38 41 44120 30 34 39 42150 33 37 41 45
Flow regulators are characterized by their noise level in dB(A).
Tests reports : CETIAT 2315002 for air flow RD Ø80 to RD Ø125 mm
Air fl
ow in
m3 /
h
∆PT, Differential pressure in Pa
RDA 80 100 125
L 55 60 90
øD1 117 96 120
øD2 73 120 117
1
2
3
3
21
D1
D2
D2
D1
L
L
SPIIris damper
FunctionThe SPI is an iris damper for measuring and adjusting the air flow. The SPI has the following specifications: low noise level, centrically formed air flow and fixed test points for precise measurements. The damper also has an adjustment aperture which can be opened completely, which means there is no need for an access door for cleaning. Available in sizesØ80-800. Max temperature for SPI is 70°C.
SPI Art-no. Ød C ØD
80 7621 79 110 125
100 6750 99 54 163
125 6751 124 63 210
150 6752 149 54 230
160 6753 159 60 230
200 6754 199 62 285
250 6755 249 62 333
300 6756 299 65 405
315 6757 314 63 406
400 6758 399 70 560
500 7625 499 60 644
630 7626 629 60 811
800 6881 798 70 1015
DesignThe damper is manufactured from galva-nised sheet steel and is fitted with a rub-ber seal tested for air-tightness.
MountingThe SPI adjustment damper must be in-stalled in accordance with the distances required to minimise air-flow deviation. The SPI enables the taking of precise air-flow measurements at all points including points close to duct deviations such as T junctions and bends, and points in front of other supply-air devices (see below).
Protective distance before bends 1 X ØDafter“ 1 X ØDbefore T-pipes 3 X ØDafter “ 1 X ØDbefore supply-air devices 3 X ØD
Ordering codeThe ordering code is SPI - 160 with sizes.
TUNE-R -
Size 80 - 630 mm
Tightness class
123
A1
C1
C4
HM0M1M2M3M4M5
M6
handle
preparation for actuator
230V actuator
24V actuator
24V, 0-10V stepless actuator
230V spring actuator
24V spring actuator
24V, 0-10V stepless spring actuatorVersion
Stainless steel(Optional)
A-304A-316
for usage in the food industry
for general usage
Tune-RSingle Blade Damper
FunctionTune-R is a control and shut off damper for round ducts. It is available in various versions with blade tightness class 1 or 4 and casing tightness class A or C tested according to EN 1751. A1 version is ideal in simple installa-tions for regulating the air volume in circular ducts. C1 ver-sion is required for duct installation with airtight require-ments towards the outside of the duct or to minimize the leakage towards the outside surroundings. It can also be used as a shut off damper for air handling units, combined with a spring return actuator. In case of power outage the damper can maintain a fully closed position. The damper’s special construction allows external insulation up to 50 mm. The damper can be supplied in a manual or
motorized version with an integrated position indicator.
DesignThe damper is manufactured from a galvanized steel sheet and is silicone-free. All the gaskets are manufactured from black rubber. Plastic bushings are from a PPO material. All the mate-rials are flame retardant.
116 | Air volume controllers
Fire Dampers | 117
Cartridge fire dampers are designed and have CE mark in accordance with EN 15650 and certified to comply with the EI-S (EN 1366-2) performance attributes. PKI-C fire dampers are designed to be embedded into fire parti-tion walls, or at the end of a duct in front of the valve. Installation of these devices is described in the Installation, Operation and Maintenance of the Cartridge Fire Dampers manual. As a standard, all the dampers are supplied in a basic version, with a microswitch, or accessories - cover plates .
The fire damper automatically sets itself to a „CLOSE“ position if the ther-mal fuse link gets ruptured. After the closure, the damper blade is mecha-nically secured in the closed position and can only be opened manually, which requires access of the maintenance staff into the duct. To improve the duct accessibility for fire damper inspection purposes, we supply a flexible coupling as an accessory- labelled as TVKC in the Ordering Codes section. The thermal fuse link releases the coupling mechanism when the air temperature in the damper exceeds 72°C.
PKI-C Cartridge Fire DampersFire resistance class EI60S, EI90S and EI120S
Main Dimensions and Weight
Ød
60 W1
ND d EI60/90/120S EI60S EI90/120S
(mm) (mm) W1 (mm) M (kg)
100
ND-1,5
27 0,3 0,3
125 39,5 0,4 0,4
140 47 0,5 0,5
150 52 0,4 0,6
160 57 0,5 0,6
180 67 0,6 0,7
200 77 0,7 0,9
Ceiling Installation
1. ceiling
2. duct
3. gypsum / mortar / concrete
4. PKI-C
5. Air valve
1
2
3
4
5
D E
D – installation into continuous ductsE – installation with a circ Air valve.
Installation Into the End of a Duct with a Valve
It is possible to install the cartridge fire damper at the end of a duct in a wall / ceiling with a valve orifice
GEO Geothermal heat exchanger unit
Items Art-no.GEO Unit, including G4-Filter, 312513
Pipe, ND 12,5Bar 304981
Heat Exchanger Liquid (-14 °C) 304989
Why choose a ground heat exchanger?In the winter, domestic heat recovery units switch to a frost protectionmode at low temperatures outside. This usually means that the supplyfan slows down, causing an imbalance between the supply and exhaust air through the heat recovery unit. Another possibility is that a (pre-) heater is turned on, which usually consumes 1 to 2kW of energy.In the summer, at high external tempera-tures, the supply air from outside can be warmer than the air inside the house. Thus, this warm supply air can heat the house while this is not preferable.The horizontal ground heat exchanger GEO can offer a solution forthe problems mentioned above, using a minimum of energy.
118 | Geothermal heat exchanger
Example of installation GEO
Dimensions
Why choose a GEO?GEO has its own control which can be used in combination with any type of heat recovery unit. This control will start the highly energyefficient pump of the GEO at specific set outside temperatures, causing the liquid to flow through the duct. The temperature of the liquid, will approach the temperature of the soil and will transfer its energy to the supply air of the heat recovery system through the battery of the GEO.By using GEO, the efficiency of the heat recovery can be increased.
Benefits• With 8W energy, you can gain up to
1.5 kW;
• Can be used in combination with any HR-unit up to 500m³/h;
• Increases the efficiency of the heat recovery unit;
• Has its own control, allowing energy con- sumption only when needed;
• Has an A label-EC pump and a G4 filter for the protection of the heat exchanger;
• Is easy to install, all in 1 case (pump, control, sensors, filters, filling and venting unit, battery, gauge, vent valve, volume meter, and pressure vessel);
• Has a right / left version in 1 unit and the air to the heat recovery unit can be mounted both on the top and on the side;
• Thanks to relatively thin duct (25 mm), it is easy to install;
• Is an hygienic and attractive solution;
• Is easy to clean: condensation develops in the Aquacom, which is led to the sewer through the condensate drain.
Geothermal heat exchanger | 119
T GEO - „T in“ is constant
Q m³/h
T °C
-15
-10
-5
0
5
10
15
20
25
30
35
0 100 200 300 400 500 600
30°C in
T out summer
T out winter
-10°C in
Above is valid with a glycol/water supply temperature of 10°C.
For example: In an average house with the Heat recovery unit at speed 2 (+/- 250m³/h)in summer the GEO will cool down the outside temperature from 30°C to 20°C.In winter the GEO will heat up the outside temperature from -10°C to 2,5°C.
0102030405060708090
100
0 100 200 300 400 500 600 700
Pressure loss GEO
Q m³/h
Pa
• Sturdy PVC housing
• Appealing design
• Excellent suction power
• Easy, flexible installation
• Easy operation and maintenance
• Long service life
Hose set with on/off switch at the handle (11 m)
Basic equipment
V20/V30Vacuum Cleaner
The central vacuum cleaner V20/V30 is a powerful, low-noise unit. Motor cooling via separate fresh air duct system to avoid soiling. The central cleaner is connected and switched to inlet valves via low volt-age wire. The dust canister is situated inside the top of the device. Dust is sepa-rated by the filter bag.Our vacuum cleaners are equipped with
safety filters and filter barriers to optimise dust separation.Complete pipe kit including all needed pipe parts, glue, pipe clips, control cable and installation Manual. Available in 3 sizes: for 1, 2 or 3 inlet valves.
Vacuum cleaner120 |
Art-No. 12550
Vacuum cleaner | 121
Contents duct kitArt-No.
1 socket3734
2 socket3735
3 socket3736
Bend 90°for connection vacuum point 1 pcs. 2 pcs. 3 pcs.
Elbow 90°(one piece swivel-mounted) 3 pcs. 7 pcs. 10 pcs.
Elbow 45°for connection duct system 2 pcs. 4 pcs. 6 pcs.
Tee 45°for connection duct system 1 pcs. 1 pcs. 1 pcs.
Tee 90°for connection duct system - - 1 pcs.
Coupling 4 pcs. 6 pcs. 8 pcs.Duct brackets 3 pcs. 5 pcs. 6 pcs. Vacuum point (surface socket) 1 pcs. 1 pcs. 1 pcs. Wall plate, for vacuum points (building shell) 1 pcs. 2 pcs. 3 pcs.
Cover plate, for vacuum points (building protection) 1 pcs. 2 pcs. 3 pcs.
Low voltage cable 24 V 10 m 17 m 30 mMounting material (package) 1 1 1Glue (bottle) 100 ml 100 ml 100 mlDuct, length 1,15 m 6 pcs. 10 pcs. 14 pcs. Installation manual 1 pcs. 1 pcs. 1 pcs.
TypeArt-No.
V20 12547
V30 12548
Power output (max.) 1 600 W 1 650 WMotor cooling Environment EnvironmentVoltage 230 V (50 Hz) 230 V (50 Hz)Control circuit 24 V 24 VSuction effect 540 W 620 WCurrent 6,3 A 6,5 ADelay fuse 10 A 10 ALow pressure (max.) 2 730 mmWs 2 880 mmWsAir flow 50 l/s 57 l/sNoise level LpA (1m) 68 dB(A) 67 dB(A)Vacuum unit container 31 l 31 lMass 23 l, single-use 23 l, single-use Gewicht approx. 7,4 kg approx. 7,9 kgMax. pipe length* approx. 30 m approx. 30 mPipe diameter Ø 50,8 mm (2”) Ø 50,8 mm (2”)
Cable length ~2,5 m cable (incl. plug)
~2,5 m cable(incl. plug)
* Pipe length between the appliance and the farthest vacuum point, inclusive exhaust air hose. The exhaust air hose should not exceed a length of 10 m. The maximum hose length has been calculated by using a hose set of 10 m.
Single vacuum point with PVC mounting frame, white
Accessories vacuum cleaner
Silencer for exhaust air Wall grid for exhaust air Wall vacuum socket
Vacuum socket Hepafilter Ash separator
Premium parquet brush with roller
Extra large brush for hard floors.
Premium turbo brush Basket for accessories
Art-No. 3744 Art-No. 3745 Art-No. 12315
Art-No. 8485 Art-No. 12549 Art-No. 12320
Art-No. 308685 Art-No. 14508 Art-No. 12318
Systemair‘s combi unit „Genius“ efficiently and economically combines the complete building equipment for energy efficient single-family houses.
Controlled room ventilation is more and more necessary for houses with modern building standards. New buildings as well as renovated buildings have higher insulation standards with less heating loads. Consequently, conventional heating systems are often over-dimensioned. Systemair‘s combi unit „Genius“ provides the solution - the ventilation system enables heating as well as cooling in an efficient way. This can be achieved by temporarily increasing the volumetric flow in combination with an air-air/air-water-heat pump. The pump also provides higher hot water comfort.Genius optimises HVAC for energy efficient buildings. Therefore, it is possible to conceive self-sufficient and CO2 neutral systems in combination with PV systems.
Controlled room ventilation with heat recovery
Controlled room ventilation with integrated heat recovery provides a balanced and agreeable indoor climate.Permanent fresh air supply into living rooms and exhaust of used air guarantee a healthy indoor climate. Heat recovery is provided by a rotating heat exchanger which transfers exhaust air heat to the supply air - the heat remains in the building.
Heating and cooling with heat pumps
Heating in winter and cooling in summer! This is made possible by a steplessly controlled air-air/air-water-heat pump.The heat pump adjusts its performance according to the requirements for a highly efficient operation.Used air is exhausted from living areas via a separate duct system and led back after treatment (heating or cooling) to living and sleeping areas. This is a pure air heating/cooling system.The exhaust system remains unaffected. Odour or substance transmission from exhausted rooms to supply air is thereby excluded.
Hot water generation
The Genius building services centre is equipped with a 150 litres drinking water reservoir. The service centre ensures hot water comfort because water treatment works during all operating modes.As a consequence, the water is heated to the required temperature parallel to heating or cooling operation.The water reservoir features an electric heating element to guarantee operation at low external temperatures.
Control unit
The control unit of the building services centre is able to control the complete heating, cooling, hot water system and ventilation.The control unit provides a user level for the owner and a service level for service personnel. The entire control unit can be controlled by an internet application.
The energy efficient Building Service CentreGenius - All in one
Genius - Building Services Centre
Combi Whole House Unit122 |
All in oneThe new „Genius“ Systemair Central Building Services Unit for energy efficient residential houses with the functions:
• Heating/Cooling/Ventilation
• Heat recovery
• Hot Water
This consists of three modules. The hot water module with stainless steel storage tank, the heat pump module with reversible air to air and air to water heatpump for heating and cooling, the ventilation and energy recovery module with energy saving fans and a rotating heat exchanger with recovery of humidity in winter and dehumidification in summer. Ventilation will be done as usual by two fans. Heating or cooling of the rooms will be provided through the supply or recirculati-on air ducts. Electrical PTC elements in the supply air elements allow independent control of individual rooms, and if necessary, balance extreme outdoor temperatures.
Compared to conventional systems, the Systemair Central Building Services Unit „Genius“ offers additional advantages, all combined in one unit:
• Ventilation with heat recovery
• Low energy use
• No extra radiators required
• Intelligent single room control
• CO2 and humidity control, optional
• Energy saving fans
• Hot water production parallel to heating operation
• Control system for the the complete building services, designed for efficient comfort operation
• Emergency mode for heating and hot water
• Legionella function, fast charging hot water
• Geothermal heat exchanger, optional
• Ventilation unit thermally isolated
Combi Whole House Unit | 123
Ventilation module
• Rotating heat exchanger with humidity recovery.
• Heating and cooling through supply air ducts (recircu-lation air).
Central Building Services Unit „Genius“ in detail
Hot water module
• 150 litres stainless steel storage tank for hot water
• Hot water production parallel to heating function.
• Electric heater with 3 kW power
Heat pump module
• Reversible air to air and air to water heat pump for heating, cooling and hot water.
• Steplessly controlled compressor to modulate the power exactly to the need of heating and cooling energy.
Genius
Heating power kW 5
Cooling power kW 4
Air flow (normal operation) m³/h 250 (100 Pa)
Heat recovery bis 88 %
Hot water l 150
Electric heater kW 3
Dimensions
Width mm 865
Heigth mm 2070
Depth mm 750
Technical data
easy installation and maintenance due to modular system.
HP Heat pump module
HW Hot water module
HRU Ventilation module
Installation and maintenance
ambient air
secondary air
exhaust air
supply air
exhaust air
ambient air HP
Combi Whole House Unit124 |
Index | 125
Index
A Page No
AE Self Regulating motorised Air Valves 110
Air Valves Various Air Valves 106
AL Self Regulating Air Valves 111
B Page No
Balance - E Balance-E Extract Plastic Air Valve 107
Balance - S Balance-S Supply Plastic Air Valve 107
BF Domestic Axial Fan 40
BHC Humidity & PIR Air Valve 112
BOREA Adjustable Air Valves 109
BRAVO Domestic Centrifugal Fan 170
C Page No
CB Electric heater battery 80
CBF Domestic Centrifugal Fan 42
CD HRU Control Panel 79
CE HRU Control Panel 78
CF Domestic Centrifugal Fan 42
CO2RT / CO2RT-D CO2 Sensors 39
Cookerhoods Cooker hoods 81
CVVx Heat Recovery Wall Grille 104
CWK LPHW Water Heater batteries 80
D Page No
Diffusers Various Diffusers 106
DSG Pressure Sensor 39
Ducting Duckwork & Accessories 91
E Page No
EC-Vent Demand Control System 35
EAF LV Domestic Low Voltage Axial Fan 41
ECF LV Domestic Low Voltage Centrif Fan 41
EFD Motorised VCD 78
EFF Metal Air Valve 106
EFS-RCK 5 in 1 Roof Cowl 105
ES Commercial 6”, 9” & 12” Fans 45
F Page No
F251 Cooker Hood 81
FAV Self Regulating Fresh Air Valves 113
FGR Panel Filter Cassette Circ 33
FK Fast Clamps 30
Flat Duct Plastic & Metal Flat Ducting 94
Flex + Plastic Duct System 84
Flexible Ducting Various Flexible Ducting 93
FSSSVLF Stainless Steel Air Valve 107
G Page No
Genius Combi Whole House Unit 122
Geo Geothermal Unit 118
H Page No
HR1 Room Humidiistat 38
I Page No
IGC Circular Wall Louvre 31
IGK Square Wall Terminal 32
IF Domestic Shower Axial Fan 40
IR24-P PIR 24V 39
ISO + Insulated Circ Ducting 101
K Page No
K-EC EC Circular Metal Tube Fan 26
KVKE-EC EC Compact Acoustic Box Fan 24
L Page No
LDC Circular Duct Silencer 102
M Page No
MTP 10 EC Fan Speed Control 0-10V 34
MVS Central Extract Fan 44
P Page No
PK-I-C Circular Fire Damper 117
R Page No
RDA Constant Air Volume Device 115
RSK Back Draught Shutter 33
RVF Domestic External Wall Fan 43
S Page No
SCD Silencer, Flexible 31
Silencers Silencers 102
SPI Iris Damper 116
T Page No
T120 Timer 38
TFSK-EC EC Roof Centrif Fan (Square Base) 28
TFSR-EC EC Roof Centrif Fan (Circ Base) 28
TFF Circ Diffuser 108
TG Temperature Sensors 38
TSL-1/EC Cooker hood 81
TST Circ Diffuser 108
Tune-R Single Blade VCD’s 116
V Page No
V20 / V30 Central Vacuum Cleaners 120
VBC LPHW Water Heater Battery Circ 80
VK Louvre Shutter 32
VR 250 ECH/B Residential Heat Recovery Unit 52
VR 300 ECV/B Residential Heat Recovery Unit 60
VR 400 DCV/B Residential Heat Recovery Unit 62
VR 700 DCV Residential Heat Recovery Unit 64
VSR 300 Residential Heat Recovery Unit 66
VSR 500 Residential Heat Recovery Unit 68
VTR 150/K Residential HRU with cookerhood 54
VTR 200/B Residential Heat Recovery Unit 56
VTC Low E Commercial Heat Recovery Unit 58
VTC 300 Commercial Heat Recovery Unit 74
VTC 700 Commercial Heat Recovery Unit 76
VTK Self-Adjusting Fresh Air Vent 114
Vx 400 E Heat Recovery Unit Side Conn 70
Vx 400 EV Heat Recovery Unit Top Conn 70
Vx 700 E Heat Recovery Unit Side Conn 70
Vx 700 EV Heat Recovery Unit Top Conn 70
W Page No
WBK Mounting Bracket 79
Syst
emai
r UK
• N
ovem
ber 2
012 •
www.systemair.co.ukwww.villavent.co.uk