Residential Deaths 2003 to 2008
• Falls - 54• Struck By -27• Electrocution – 26• Forklift -11• Trenching - 4• Fire – 2• Environmental - 2• Health -3 • Drown - 2
No guard rails on scaffold
![Page 3: Residential Safety 2009](https://reader036.fdocuments.us/reader036/viewer/2022062513/5555c1f5d8b42aaf158b456c/html5/thumbnails/3.jpg)
Fall Sources
• 19 roof Falls• 11 Ladder Falls• 8 Floor/stair openings• Fall protection starts
at 6 feet for residential carpentry
Slides off roofs are leading cause of residential falls
![Page 4: Residential Safety 2009](https://reader036.fdocuments.us/reader036/viewer/2022062513/5555c1f5d8b42aaf158b456c/html5/thumbnails/4.jpg)
Stuck By
• Falling objects from roof• Falling objects being lifted
to roof• Walls• Vehicles• Working under objects
that had support fail• Truss Collapse• Trailer unloading –
Concrete pipe
Crane or forklift is recommended
![Page 5: Residential Safety 2009](https://reader036.fdocuments.us/reader036/viewer/2022062513/5555c1f5d8b42aaf158b456c/html5/thumbnails/5.jpg)
Electrocutions
• Powerlines – 20(Most ladders and
gutters)• Pressure tank – 1• Air Handler – 1• Lighting circuit – 1• Electrical cord – 1• Brick Scraper – 1• Scaffold - 1
10 feet away is required.
![Page 6: Residential Safety 2009](https://reader036.fdocuments.us/reader036/viewer/2022062513/5555c1f5d8b42aaf158b456c/html5/thumbnails/6.jpg)
Trenching
• No cave in protection• No ladder within 25
feet• No competent person• Quick disconnect
bucket hazard
![Page 7: Residential Safety 2009](https://reader036.fdocuments.us/reader036/viewer/2022062513/5555c1f5d8b42aaf158b456c/html5/thumbnails/7.jpg)
Other Factors
• Drugs – including cocaine were found in some victim’s system
• Training – many not trained in 1926.503 requirements
Cocaine stored in a used prescription container
![Page 8: Residential Safety 2009](https://reader036.fdocuments.us/reader036/viewer/2022062513/5555c1f5d8b42aaf158b456c/html5/thumbnails/8.jpg)
Weather
• Heat Stress• Lightning• Wind
![Page 9: Residential Safety 2009](https://reader036.fdocuments.us/reader036/viewer/2022062513/5555c1f5d8b42aaf158b456c/html5/thumbnails/9.jpg)
Fire
• Painting truck catches on fire
![Page 10: Residential Safety 2009](https://reader036.fdocuments.us/reader036/viewer/2022062513/5555c1f5d8b42aaf158b456c/html5/thumbnails/10.jpg)
Shingling Falls
• Most the falls are those with no slide guards
• Workers can slip on shingle or felt to start slipping
No slide protection used
![Page 11: Residential Safety 2009](https://reader036.fdocuments.us/reader036/viewer/2022062513/5555c1f5d8b42aaf158b456c/html5/thumbnails/11.jpg)
Shingling Abatement
• Slide guards used when:• Roof Slope 8/12 or less• Eaves to lower level is 25
feet or less• Otherwise Convention
Fall protection must be used
• Must be through each truss with a 16p nail
• A 2x4 nailed flat is not acceptable
Example of slide guard.
![Page 12: Residential Safety 2009](https://reader036.fdocuments.us/reader036/viewer/2022062513/5555c1f5d8b42aaf158b456c/html5/thumbnails/12.jpg)
Roof Sheathing
• Conventional Fall Protection or Alternative Fall Protection requiring:
• Monitor• CAZ• Slideguard• Training
No slide guards used
![Page 13: Residential Safety 2009](https://reader036.fdocuments.us/reader036/viewer/2022062513/5555c1f5d8b42aaf158b456c/html5/thumbnails/13.jpg)
Sheathing Abatement
Conventional Fall Protection used
Slideguards used on the roofs.
![Page 14: Residential Safety 2009](https://reader036.fdocuments.us/reader036/viewer/2022062513/5555c1f5d8b42aaf158b456c/html5/thumbnails/14.jpg)
Controlled Access Zones
• Alternative methods• Floor joist installation• Erecting Exterior
walls• Sheathing• Roof Truss Erection
![Page 15: Residential Safety 2009](https://reader036.fdocuments.us/reader036/viewer/2022062513/5555c1f5d8b42aaf158b456c/html5/thumbnails/15.jpg)
Top Plate
• The worker has to get on the top plate to give leverage and assist the center man with the large truss.
• The interim protection rules, NAHB, RCEC, and carpenters all state that it is a violation, however, many contractors still think it is ok.
![Page 16: Residential Safety 2009](https://reader036.fdocuments.us/reader036/viewer/2022062513/5555c1f5d8b42aaf158b456c/html5/thumbnails/16.jpg)
Floor Openings
• Many falls through openings were stair openings
Violation: Floor opening with no guardrails.
![Page 17: Residential Safety 2009](https://reader036.fdocuments.us/reader036/viewer/2022062513/5555c1f5d8b42aaf158b456c/html5/thumbnails/17.jpg)
Floor Opening Abatement
Violation: 4' x 8' sheets of plywood covering a stairway opening to the basement of a house. Only four nails hold the two covers. The cover is not marked.
No Violation: Guardrails used
![Page 18: Residential Safety 2009](https://reader036.fdocuments.us/reader036/viewer/2022062513/5555c1f5d8b42aaf158b456c/html5/thumbnails/18.jpg)
Extension Ladders
• Ladder contacting electrical caused employee to fall in some cases.
• Carrying material up ladder perhaps another fall cause.
Violation: Ladder used to support plank.
![Page 19: Residential Safety 2009](https://reader036.fdocuments.us/reader036/viewer/2022062513/5555c1f5d8b42aaf158b456c/html5/thumbnails/19.jpg)
Extension Ladder Abatement
• Extend ladder 3 feet above access roof
• Work within side rails• Secure it from
movement• 10 feet from electrical
lines
![Page 20: Residential Safety 2009](https://reader036.fdocuments.us/reader036/viewer/2022062513/5555c1f5d8b42aaf158b456c/html5/thumbnails/20.jpg)
Ladderjack Scaffold
• Work is often siding• No fall arrest worn
![Page 21: Residential Safety 2009](https://reader036.fdocuments.us/reader036/viewer/2022062513/5555c1f5d8b42aaf158b456c/html5/thumbnails/21.jpg)
Ladder Jack Abatement
• Fall arrest is often a roof anchorage, rope grab, and body harness.
![Page 22: Residential Safety 2009](https://reader036.fdocuments.us/reader036/viewer/2022062513/5555c1f5d8b42aaf158b456c/html5/thumbnails/22.jpg)
Open Sided Floor
• No guardrail at open sides above 6 feet
• Often material handling is the reason no rails are not in place.
![Page 23: Residential Safety 2009](https://reader036.fdocuments.us/reader036/viewer/2022062513/5555c1f5d8b42aaf158b456c/html5/thumbnails/23.jpg)
Open Side Floor Abatement
• Floor sheathing abatement using alternative fall protection methods.
No Violation: Area for wall building marked off six feet from edge.
![Page 24: Residential Safety 2009](https://reader036.fdocuments.us/reader036/viewer/2022062513/5555c1f5d8b42aaf158b456c/html5/thumbnails/24.jpg)
Truss Bracing
• Trusses have to have horizontal and diagonal bracing to prevent a truss collapse.
• Cited 5(a)(1) per Truss Plate Institute Guidelines
![Page 25: Residential Safety 2009](https://reader036.fdocuments.us/reader036/viewer/2022062513/5555c1f5d8b42aaf158b456c/html5/thumbnails/25.jpg)
Truss Lifting
• Lifting the truss at one point can cause the truss to separate/break and fall.
• Use a spreader bar or a forklift.
![Page 26: Residential Safety 2009](https://reader036.fdocuments.us/reader036/viewer/2022062513/5555c1f5d8b42aaf158b456c/html5/thumbnails/26.jpg)
Carbon Monoxide
• Winter time is worst time for temporary heaters.
• No venting and use of fuels inside.
![Page 27: Residential Safety 2009](https://reader036.fdocuments.us/reader036/viewer/2022062513/5555c1f5d8b42aaf158b456c/html5/thumbnails/27.jpg)
Forklifts
• Tip over• Untrained operators• All can use it• Riding pallet or home
made platforms that fall off.
• Forklift ran over employee
![Page 28: Residential Safety 2009](https://reader036.fdocuments.us/reader036/viewer/2022062513/5555c1f5d8b42aaf158b456c/html5/thumbnails/28.jpg)
Vehicles
• Vehicle backed over employee
![Page 29: Residential Safety 2009](https://reader036.fdocuments.us/reader036/viewer/2022062513/5555c1f5d8b42aaf158b456c/html5/thumbnails/29.jpg)
Health
• Basement spray painting
• Methylene Chloride - 2
![Page 30: Residential Safety 2009](https://reader036.fdocuments.us/reader036/viewer/2022062513/5555c1f5d8b42aaf158b456c/html5/thumbnails/30.jpg)
Swing Radius
• Aerial lifts• Excavator
![Page 31: Residential Safety 2009](https://reader036.fdocuments.us/reader036/viewer/2022062513/5555c1f5d8b42aaf158b456c/html5/thumbnails/31.jpg)
Bracing walls
• Masonry Walls (See Masonry Institute Guidelines)
• Concrete foundations• Concrete Forms
![Page 32: Residential Safety 2009](https://reader036.fdocuments.us/reader036/viewer/2022062513/5555c1f5d8b42aaf158b456c/html5/thumbnails/32.jpg)
Rotten Roofs
• Roof tear off on old roofs can pose a danger for falling through the roof.
![Page 33: Residential Safety 2009](https://reader036.fdocuments.us/reader036/viewer/2022062513/5555c1f5d8b42aaf158b456c/html5/thumbnails/33.jpg)
Residential Top Ten Cited
![Page 34: Residential Safety 2009](https://reader036.fdocuments.us/reader036/viewer/2022062513/5555c1f5d8b42aaf158b456c/html5/thumbnails/34.jpg)
#1
• 1926.501(b)(13)
• No Fall Protection during residential construction
• Sheathing – no slideguards
• Shingling – no fall protection
![Page 35: Residential Safety 2009](https://reader036.fdocuments.us/reader036/viewer/2022062513/5555c1f5d8b42aaf158b456c/html5/thumbnails/35.jpg)
#2
• 1926.501(b)(1)
• No guardrails on open sided floors
![Page 36: Residential Safety 2009](https://reader036.fdocuments.us/reader036/viewer/2022062513/5555c1f5d8b42aaf158b456c/html5/thumbnails/36.jpg)
#3
• 1926.503 (a)(1)
• The employer shall provide a training program for each employee who might be exposed to fall hazards. The program shall enable each employee to recognize the hazards of falling and shall train each employee in the procedures to be followed in order to minimize these hazards.
No slide guard or fall protection used
![Page 37: Residential Safety 2009](https://reader036.fdocuments.us/reader036/viewer/2022062513/5555c1f5d8b42aaf158b456c/html5/thumbnails/37.jpg)
#4
• 1926.100 (a)
• No Hard hats
Working below scaffolds requires hard hats
![Page 38: Residential Safety 2009](https://reader036.fdocuments.us/reader036/viewer/2022062513/5555c1f5d8b42aaf158b456c/html5/thumbnails/38.jpg)
#5
• 1926.102(a)(1)
• No eye protection
Nail guns are a common source of eye injuries.
![Page 39: Residential Safety 2009](https://reader036.fdocuments.us/reader036/viewer/2022062513/5555c1f5d8b42aaf158b456c/html5/thumbnails/39.jpg)
#6
• 1926.451 (g)(1)
• No guardrails on scaffolds
No guardrails, poor access.
![Page 40: Residential Safety 2009](https://reader036.fdocuments.us/reader036/viewer/2022062513/5555c1f5d8b42aaf158b456c/html5/thumbnails/40.jpg)
#7
• 1926.453 (b)(2)(v)
• No fall arrest in aerial lifts
![Page 41: Residential Safety 2009](https://reader036.fdocuments.us/reader036/viewer/2022062513/5555c1f5d8b42aaf158b456c/html5/thumbnails/41.jpg)
#8
• 1926.1053 (b)(1)
• No extending ladders 3 feet above landing.
This ladder extends 3 feet above the landing.
![Page 42: Residential Safety 2009](https://reader036.fdocuments.us/reader036/viewer/2022062513/5555c1f5d8b42aaf158b456c/html5/thumbnails/42.jpg)
#9
• 1926.20 (b)(2)
• No Competent Person
Putting plywood over an opening without marking and securing it is very dangerous.
![Page 43: Residential Safety 2009](https://reader036.fdocuments.us/reader036/viewer/2022062513/5555c1f5d8b42aaf158b456c/html5/thumbnails/43.jpg)
#10
• 1926.20 (b)(1)
• Deficient Safety Program
Working on a pallet is very dangerous.
![Page 44: Residential Safety 2009](https://reader036.fdocuments.us/reader036/viewer/2022062513/5555c1f5d8b42aaf158b456c/html5/thumbnails/44.jpg)
Information
• Data used from 2003-2008 from Region V
• Prepared by CSP John Newquist, Bill Donovan, and Jim Martinek