Representative Sampling By Chuck Abbott. Automatic Samplers.
-
Upload
christiana-sparks -
Category
Documents
-
view
227 -
download
0
Transcript of Representative Sampling By Chuck Abbott. Automatic Samplers.
![Page 1: Representative Sampling By Chuck Abbott. Automatic Samplers.](https://reader038.fdocuments.us/reader038/viewer/2022102818/56649d025503460f949d51cc/html5/thumbnails/1.jpg)
Representative SamplingBy
Chuck Abbott
![Page 2: Representative Sampling By Chuck Abbott. Automatic Samplers.](https://reader038.fdocuments.us/reader038/viewer/2022102818/56649d025503460f949d51cc/html5/thumbnails/2.jpg)
Automatic Samplers
![Page 3: Representative Sampling By Chuck Abbott. Automatic Samplers.](https://reader038.fdocuments.us/reader038/viewer/2022102818/56649d025503460f949d51cc/html5/thumbnails/3.jpg)
Industry Sampler NeedsIf sampler required, usually going to be
refrigeratedPermit determines type of sampling needed and
frequencySequential sampling in multiple bottlesComposite samples
Permit determines if any additional monitoring is neededFlow pacing for flow proportional samplespH monitoring and ability to enable sampler to
take sample on high or low pH event
![Page 4: Representative Sampling By Chuck Abbott. Automatic Samplers.](https://reader038.fdocuments.us/reader038/viewer/2022102818/56649d025503460f949d51cc/html5/thumbnails/4.jpg)
Sequential Sampling Usually done when
monitoring for specific events like slugs.
Used by enforcement to check industry and determine pollutant trending
Multiple bottles are used with the standard being the 24 bottle sampler.
One or more samples collected in individual bottle each hour.
flexible enough to take samples/bottle or multiple bottles/sample
![Page 5: Representative Sampling By Chuck Abbott. Automatic Samplers.](https://reader038.fdocuments.us/reader038/viewer/2022102818/56649d025503460f949d51cc/html5/thumbnails/5.jpg)
Pro Pak•Alternative to polypro bottles. •Designed to reduce bottle cleaning cost•Disposable•Sequential bags or composite bag
•Directly replaces Polypro Bottles
![Page 6: Representative Sampling By Chuck Abbott. Automatic Samplers.](https://reader038.fdocuments.us/reader038/viewer/2022102818/56649d025503460f949d51cc/html5/thumbnails/6.jpg)
Pre-treatment Trends
Pre-treatment groups are moving towards Portable Refrigerated Samplers as well as compact units such as the GLS
![Page 7: Representative Sampling By Chuck Abbott. Automatic Samplers.](https://reader038.fdocuments.us/reader038/viewer/2022102818/56649d025503460f949d51cc/html5/thumbnails/7.jpg)
Pre-Treatment group monitoring needs.Usually portable samplersNormally use composite but have
applications that call for multibottleNeed flexible program capabilities
May need 2 part program Flow proportional sampling Sample enabled/ triggers based on events
![Page 8: Representative Sampling By Chuck Abbott. Automatic Samplers.](https://reader038.fdocuments.us/reader038/viewer/2022102818/56649d025503460f949d51cc/html5/thumbnails/8.jpg)
Stored Data
Data can be stored in either 2105 or 6712 internal data logger
•Data Collected via Flowlink 5.1
![Page 9: Representative Sampling By Chuck Abbott. Automatic Samplers.](https://reader038.fdocuments.us/reader038/viewer/2022102818/56649d025503460f949d51cc/html5/thumbnails/9.jpg)
Important features for Industrial pre-treatment useAccurate and repeatable volume deliverMultiple bottle capabilitiesAccurate liquid detection systemAble to take samples based on flow input or
based on time or a combination of imputsAble to store sample, flow and other data that
can be retrieved laterEasy to maintain
![Page 10: Representative Sampling By Chuck Abbott. Automatic Samplers.](https://reader038.fdocuments.us/reader038/viewer/2022102818/56649d025503460f949d51cc/html5/thumbnails/10.jpg)
Bottle Options
![Page 11: Representative Sampling By Chuck Abbott. Automatic Samplers.](https://reader038.fdocuments.us/reader038/viewer/2022102818/56649d025503460f949d51cc/html5/thumbnails/11.jpg)
Sample Size and FrequencyMinimum sample volume
collected with an automatic sampler should be no less than 10 ml.
Recommended size is no less than 50 ml because of liquid detector Sample volume
repeatability Volume required by lab Bigger is better theory
![Page 12: Representative Sampling By Chuck Abbott. Automatic Samplers.](https://reader038.fdocuments.us/reader038/viewer/2022102818/56649d025503460f949d51cc/html5/thumbnails/12.jpg)
![Page 13: Representative Sampling By Chuck Abbott. Automatic Samplers.](https://reader038.fdocuments.us/reader038/viewer/2022102818/56649d025503460f949d51cc/html5/thumbnails/13.jpg)
Preventative SamplerMaintenancePump tubing replacementSuction line replacementContainer replacementDiagnostic routinesVolume calibration
![Page 14: Representative Sampling By Chuck Abbott. Automatic Samplers.](https://reader038.fdocuments.us/reader038/viewer/2022102818/56649d025503460f949d51cc/html5/thumbnails/14.jpg)
Pump CounterCounts actual revolutionsDetermines pump time
not related to timenot affected by battery
Specifiable Feature!
![Page 15: Representative Sampling By Chuck Abbott. Automatic Samplers.](https://reader038.fdocuments.us/reader038/viewer/2022102818/56649d025503460f949d51cc/html5/thumbnails/15.jpg)
6712 Pump TubingBands indicate position
bands won’t slipLabel for pump
shows installation, direction
![Page 16: Representative Sampling By Chuck Abbott. Automatic Samplers.](https://reader038.fdocuments.us/reader038/viewer/2022102818/56649d025503460f949d51cc/html5/thumbnails/16.jpg)
0.29”0.25”
![Page 17: Representative Sampling By Chuck Abbott. Automatic Samplers.](https://reader038.fdocuments.us/reader038/viewer/2022102818/56649d025503460f949d51cc/html5/thumbnails/17.jpg)
Tubing Life IndicatorSet for 1,000,000 countsAdjustable
site conditionsMaintenance tool
![Page 18: Representative Sampling By Chuck Abbott. Automatic Samplers.](https://reader038.fdocuments.us/reader038/viewer/2022102818/56649d025503460f949d51cc/html5/thumbnails/18.jpg)
![Page 19: Representative Sampling By Chuck Abbott. Automatic Samplers.](https://reader038.fdocuments.us/reader038/viewer/2022102818/56649d025503460f949d51cc/html5/thumbnails/19.jpg)
![Page 20: Representative Sampling By Chuck Abbott. Automatic Samplers.](https://reader038.fdocuments.us/reader038/viewer/2022102818/56649d025503460f949d51cc/html5/thumbnails/20.jpg)
Industrial MonitoringIntegral monitoring of flow, level, pH,
temperature and SDI-12 parametersDiscreet bottle samplingFlexibility in programming
2 part programmingNon-uniform time/ random time intervalsTime enables
![Page 21: Representative Sampling By Chuck Abbott. Automatic Samplers.](https://reader038.fdocuments.us/reader038/viewer/2022102818/56649d025503460f949d51cc/html5/thumbnails/21.jpg)
Volume DeliveryLD90 and pump counterMost accurate volumes
prevents biasing in samplesprevents overflows
+/- 5 ml repeatability
![Page 22: Representative Sampling By Chuck Abbott. Automatic Samplers.](https://reader038.fdocuments.us/reader038/viewer/2022102818/56649d025503460f949d51cc/html5/thumbnails/22.jpg)
Types of SamplesDistribution
Composite Single Bottle
Sequential Multiple Bottles
Samples Per Bottle Bottles Per Sample
PacingTimeFlowEvent
![Page 23: Representative Sampling By Chuck Abbott. Automatic Samplers.](https://reader038.fdocuments.us/reader038/viewer/2022102818/56649d025503460f949d51cc/html5/thumbnails/23.jpg)
Types of SamplesComposite
Composite samples are small volumes of sample taken over time and placed in a large container.
Composite samples can be taken in two ways, fixed volume or flow proportional
![Page 24: Representative Sampling By Chuck Abbott. Automatic Samplers.](https://reader038.fdocuments.us/reader038/viewer/2022102818/56649d025503460f949d51cc/html5/thumbnails/24.jpg)
Composite
1
2
3
4
5
![Page 25: Representative Sampling By Chuck Abbott. Automatic Samplers.](https://reader038.fdocuments.us/reader038/viewer/2022102818/56649d025503460f949d51cc/html5/thumbnails/25.jpg)
Sequential Sampling Usually done when monitoring
for specific events like slugs. Used by enforcement to check
industry and determine pollutant trending
Multiple bottles are used with the standard being the 24 bottle sampler.
One or more samples collected in individual bottle each hour.
flexible enough to take samples/bottle or multiple bottles/sample
![Page 26: Representative Sampling By Chuck Abbott. Automatic Samplers.](https://reader038.fdocuments.us/reader038/viewer/2022102818/56649d025503460f949d51cc/html5/thumbnails/26.jpg)
Sequential Sampling
1 2 3 4 5 6
![Page 27: Representative Sampling By Chuck Abbott. Automatic Samplers.](https://reader038.fdocuments.us/reader038/viewer/2022102818/56649d025503460f949d51cc/html5/thumbnails/27.jpg)
Two Part Programming
1 2 3 4 5 6
2
1
4
3
6
5
8
7
Part A Part B
1 2 3 4 5 6 10987 11-24
![Page 28: Representative Sampling By Chuck Abbott. Automatic Samplers.](https://reader038.fdocuments.us/reader038/viewer/2022102818/56649d025503460f949d51cc/html5/thumbnails/28.jpg)
Sampler PacingTime
Uniform Time- Fixed Volume Uniform Time- Volume Dependent Uniform- Flow Dependent Volume Non Uniform Time Random Time
Flow Flow Paced – Time Override
Trigger and Event Pacing
![Page 29: Representative Sampling By Chuck Abbott. Automatic Samplers.](https://reader038.fdocuments.us/reader038/viewer/2022102818/56649d025503460f949d51cc/html5/thumbnails/29.jpg)
Challenging sampling application accessoriesDifficult to reach locationsSampling from Pressurized linesSampling from Flumes and WeirsSampling in low flow conditionsBatch Dischargers and how to get a
representative sample.
![Page 30: Representative Sampling By Chuck Abbott. Automatic Samplers.](https://reader038.fdocuments.us/reader038/viewer/2022102818/56649d025503460f949d51cc/html5/thumbnails/30.jpg)
Best Sampler LocationAccessibility
Close to source Conserve power Maintain line velocity Reduce wear Protect suction line Minimize lift
Max lift- 8.5m/28ft Auxiliary pump
Safety of PersonnelSecurity Availability of Power SourceGood mixing for representative
samples
![Page 31: Representative Sampling By Chuck Abbott. Automatic Samplers.](https://reader038.fdocuments.us/reader038/viewer/2022102818/56649d025503460f949d51cc/html5/thumbnails/31.jpg)
How to get best representative sampleUse proper strainer
size and typeKeep intake tube short
and as vertical as you can
Keep sampler close to sampling point
Change Pump Tubing when needed.
Change intake tubing often and keep clean
![Page 32: Representative Sampling By Chuck Abbott. Automatic Samplers.](https://reader038.fdocuments.us/reader038/viewer/2022102818/56649d025503460f949d51cc/html5/thumbnails/32.jpg)
Strainer Placement -Flumes
![Page 33: Representative Sampling By Chuck Abbott. Automatic Samplers.](https://reader038.fdocuments.us/reader038/viewer/2022102818/56649d025503460f949d51cc/html5/thumbnails/33.jpg)
Strainer Placement - WeirsStrainer location here is not going to enable a representative sample to be taken.
![Page 34: Representative Sampling By Chuck Abbott. Automatic Samplers.](https://reader038.fdocuments.us/reader038/viewer/2022102818/56649d025503460f949d51cc/html5/thumbnails/34.jpg)
Isco Flow Thru ChamberFlow-thru chambers are available for use in low pressure (under 30 PSI) closed pipe applications.
![Page 35: Representative Sampling By Chuck Abbott. Automatic Samplers.](https://reader038.fdocuments.us/reader038/viewer/2022102818/56649d025503460f949d51cc/html5/thumbnails/35.jpg)
Suction Line RequirementsSimilar to strainerfollow most stringent requirementif glass needed, use Teflon suction lineclean and/or replace as needed
![Page 36: Representative Sampling By Chuck Abbott. Automatic Samplers.](https://reader038.fdocuments.us/reader038/viewer/2022102818/56649d025503460f949d51cc/html5/thumbnails/36.jpg)
![Page 37: Representative Sampling By Chuck Abbott. Automatic Samplers.](https://reader038.fdocuments.us/reader038/viewer/2022102818/56649d025503460f949d51cc/html5/thumbnails/37.jpg)
Pressurized Line SamplingTeledyne Isco now offers pressurized sampling systems to allow sample collect from pressure lines less than 300 psi.
![Page 38: Representative Sampling By Chuck Abbott. Automatic Samplers.](https://reader038.fdocuments.us/reader038/viewer/2022102818/56649d025503460f949d51cc/html5/thumbnails/38.jpg)
Spa Products
Specially developed products to help meet you sampling needs:
•Black Vinyl Suction line
•Ultra Low flow strainer
•Customer support hangers such as the Pro Hanger•Remote pump option
![Page 39: Representative Sampling By Chuck Abbott. Automatic Samplers.](https://reader038.fdocuments.us/reader038/viewer/2022102818/56649d025503460f949d51cc/html5/thumbnails/39.jpg)
Low Flowing PipesLow Flow Strainer
1/4” to 3/8”¼” suction line
![Page 40: Representative Sampling By Chuck Abbott. Automatic Samplers.](https://reader038.fdocuments.us/reader038/viewer/2022102818/56649d025503460f949d51cc/html5/thumbnails/40.jpg)
Batch discharging and representative samplingWhen taking a sample
from any source it must be representative of the source.
Sampling a batch discharger best done with flow proportional sampling method
Liquid level indicator or trigger based on level or rate of change
![Page 41: Representative Sampling By Chuck Abbott. Automatic Samplers.](https://reader038.fdocuments.us/reader038/viewer/2022102818/56649d025503460f949d51cc/html5/thumbnails/41.jpg)
Batch discharge example with flow paced sampling when triggered by level increase
![Page 42: Representative Sampling By Chuck Abbott. Automatic Samplers.](https://reader038.fdocuments.us/reader038/viewer/2022102818/56649d025503460f949d51cc/html5/thumbnails/42.jpg)
AlarmingBoth discreet and digital alarms available
•SPA 697 for contact closure•SPA 1489 CDMA Modem
•SMS Alarms
![Page 43: Representative Sampling By Chuck Abbott. Automatic Samplers.](https://reader038.fdocuments.us/reader038/viewer/2022102818/56649d025503460f949d51cc/html5/thumbnails/43.jpg)
Remote Communication
Remote Communication through 2105 C Module as well as SPA 1489 CDMA Modem
![Page 44: Representative Sampling By Chuck Abbott. Automatic Samplers.](https://reader038.fdocuments.us/reader038/viewer/2022102818/56649d025503460f949d51cc/html5/thumbnails/44.jpg)
Any Questions?