Report Out: Smart Eco-Districts DC
-
Upload
us-ignite -
Category
Technology
-
view
279 -
download
1
Transcript of Report Out: Smart Eco-Districts DC
Global City Teams Challenge
2016 KickoffNovember 12-13, 2015
Report Out: Smart Eco-Districts DC
Project Scope
• Description– Scale Existing GCTC 2015 Project PA 2040
– Develop and Connect Four Eco Districts in DC
– Create an Open Data System to Share Data
• Potential Lead / Partners – DC Net, DC IoT, NCPC, Downtown BID, DDOE,
Wash. COG
– GWU, Siemens, Phillips, Mont. County, Trimble, FediFM/Onuma
IoT Capabilities on Pennsylvania Ave NW
PA 2040
Pennsylvania Avenue West of the White House – Concept Plan
Courtesy of KGP Design Studio
PA 2040
Project Approach
• Major Requirements / Actions
– Acquire or Build a Sensor Array (anyComm, Intel Tool Kit, Array of Things?)
– Define an Open Data Hub (OCTO or GWU)
– Prioritize Key Performance Indicator (KPI) Goals
– Research Power Sources and Permitting Concerns
Project Approach
• Major Requirements / Actions
– Acquire or Build a Sensor Array (anyComm, Intel Tool Kit, Array of Things?)
– Define an Open Data Hub (OCTO or GWU)
– Prioritize Key Performance Indicator (KPI) Goals
– Research Power Sources and Permitting Concerns
Performance Targets /Indicators
• Performance Targets/KPIs – Reduce Building Energy Use (EUI’s) by X%– Improve Air Quality Across the City
• Measurement Methods for Performance/KPIs– EUI’s based on Existing Building performance Data– Environment: Temperature, Humidity, Barometric
Pressure, Sound, Air Quality:– NO2 (Nitrogen Dioxide): <2 ppb– O3 (Ozone) < 5 ppb CO (Carbon Monoxide) < 1 ppm
SO2 (Sulfur Dioxide) < 15 ppb H2S (Hydrogen Sulfide) < 2 ppb
Performance Targets /Indicators
Data Gathering Existing Conditions Data
Performance Targets /IndicatorsSingle Building Energy Analysis Sheets
Power Control and Status MonitorNode Control andCommunicaNons:Odroid-‐C1+ (Linux)
In-‐Situ Processing*:Odroid-‐XU4 (Linux)
Air Quality:NO2 (Nitrogen Dioxide): <2 ppb
O3 (Ozone) < 5 ppb CO (Carbon Monoxide) < 1 ppm
SO2 (Sulfur Dioxide) < 15 ppb H2S (Hydrogen Sulfide) < 2 ppb
Environment: Temperature, Humidity, Barometric
Pressure, VibraKon, Sound,Magnetometer, RF
*all images processed in-‐situ and discardedNo images saved or transmi*ed.
Light/Visual: Light, Infrared (surface
temperature, cloud cover), 5MP HD
Camera*
Conceptual housing design to be finalized November 2015.
Sensors(October 2015)
Open Source ResilientSupport Plaoorm
Sensor Array Urban and Green Spaces Node Configuration(Oct. 2015)
Planned for 2016:TOX (total oxidizing index) < 1 ppm
(CO equiv)
TOR (total reducing index) < 2 ppb (NO2 equiv) HCHO(Formaldehyde) VOC (VolaFle Organic Compound) CH4
(Methane) PM 2.5(ParFculate MaWer)
Open source node soXware and hardware design©Argonne NaFonal Laboratory
Performance Targets /Indicators
Performance Targets /Indicators
Performance Targets /Indicators
Open Data Building Dash Board
Demonstration/Deployment
• Phase I Demonstration Scenario– Complete PA 2040 with the Addition of Environmental
Sensor Arrays– Develop Sensor Array Prototype– Work with Educators to Teach Environmental Activism
through the Implementation of Smart Cities
• Phase II Deployment Scenario– Complete the Smart Eco-District Pilots in each District– Deploy an Open Data Eco-District Hub– Establish a Sensor Developer Program at Phelps HS,
DCPS for Engineering Design and Construction.