Report of the NTPC Test Experiment in 2007Sep and Others Yohei Nakatsugawa.

29
eport of the NTPC Test Experime in 2007Sep and Others Yohei Nakatsugawa

Transcript of Report of the NTPC Test Experiment in 2007Sep and Others Yohei Nakatsugawa.

Report of the NTPC Test Experimentin 2007Sep and Others

Yohei Nakatsugawa

NTPC test experiment in 2007Sep

●beam time: 2007Sep 20 – Oct 04

●test experiment with almost full setup ・ NTPC ・ LEPS spectrometer ・ new LH2 target ・ new drift chamber ・ trigger scintillators ・ magnetic Field 2Tesla

Set up

Fwdsolenoid

dipole

TPC

inner

outer

new

DC

ACtargetγ

※not scaled

New Liquid Target System

● will be reported by Maeda-san

New Drift Chamber

●will be reported by Sawada-san

Inner Scintillators

・ 6 counters (1 for each sector)

・ one-side read out

・ fiber light guide

・ bad time resolution ~800ps RF separation using tagger

will be reported by Yamamura-kun

1

2

3

4

5

6

Outer Scintillators

・ 12 counters ( 2 for each sector)

・ Both sides are read out.( 24 PMT’s)・ time resolution = ~180ps

Forward Scintillators

・ temporary use ( Top & bottom ones wereused for 1st TPC exp.The other one is from ring cyclotron. )

will be replaced by 4 new ones (designed by Kon-kun)

Set up

Set up

Set up

Trigger Condition

● “Sector” trigger ・ inner ( OR of opposite 4 outers ) e.g. Sector2 trigger = (inner 2) (outer 2 3 4 5 )

123

45

6

1

2

34

5

6

7

8

910

11

12

charged particle on Sector2

1

2

3

4

5

6

●At least one “Sector” hit should be required. = more than one charged particle in TPC

・ outer = upstream PMT downstream PMT

Problem & Final Trigger

solenoid

TPC

● magnetic field of solenoid no signal from upstream PMT’s ! (even though PMT’s were covered by iron shields)

We could not use coincidence triggers of outer scintillators . Only signal from downstream PMT’s were used as trigger signal of outer.

●tagger rate was very low ~60kcps inner OR trigger ( (inner 1 2 3 4 5 6 ) AC ~40cps DAQ acceptable rate We used inner OR as main trigger. (minimum bias)

Angle of Upstream PMT

solenoid

no signalsignal

●Best PMT angle was searched during no beam time in November.

●Highest signal was obtained at vertical.

●Additional light guides have been made.

Event Display

x

yy

z

“Circle” Event

●low energy electron?●inner OR trigger contains too many “circle” events. hadron-like events (events with clean track) … ~10% “Sector” trigger strongly suppress “circle” events. hadron-like events … 80~90%

“Sector” hits should be required to reduce trigger rate.

Analysis

●analyzer for newTPC ( NTPCana ) is under construction.●TPCana modified for newTPC●main difference … geometry 1st TPC : concentric circle layers , r-φcoordinate newTPC : 6 sectors , x-y coordinate in local sector

φ

rx

y

Analysis

●tracking strategy ・ find hits and determine coordinates of hit positions in local sector

・ transform from local sector to global system

・ find track candidates in global system

・ Runge-Kutta tracking in global system and calculate residual in local sector

Analysis

●ExB effect on drift electrons ・ ExB correction already applied to hit position

・  residual of helix fitting was improved.    310 μm 270μm ( no cut of drift length, track angle )

・ Map of magnetic field was made with RADIA by Yamamura-kun. (Original code of RADIA was made by Ishikawa-san for 1st TPC experiment.)

Analysis

●To Do ・ y coordinate determination using wire ADC ( x : center of gravity of ADC value of pad y : center of gravity of ADC value of wire) identification of wire pulse which corresponds to pad hit

・ dip angle dependence of pad gain Correction of ADC value of pad is needed. dE/dx resolution

y1

y2

y3

y4

y5

x=p3

x3x2x1

y

cosmic ray data

  |θ|<5° 5°<|θ|<10° 10°<|θ|<15°15°<|θ|<20°20°<|θ|<25°25°<|θ|<30°

z

padplane

θ CR

peakpad ADC

~150mmCFRP cap

VTZ

●vertex distribution of 2 track event●Clear shape of LH2 target and CFRP cap can be seen.

VTZ of gas target

●LH2 shape disappeared CFRP remained

VTX & VTY

vtx vty

dE/dx vs momentumdE

/dx

momentum * charge[GeV]

Beam Time in 2008

● NTPC experiment 2008.Jan.25 -- Feb.25 Apr. 5 -- Apr.24 May.12 -- Aug.1

Physics Motivation

●   Θ+ photoproduction accompanied by K* meson with deep UV laser (Eg ~ 3GeV)

●   TPC can detect decay particles with large acceptance. invariant mass of Θ+ Θ+ K0 + p   ππ

● There are some theoretical calculation which suggest decay asymmetry K* from neutron target is sensitive to parity of Θ+.