EVALUATION OF FLOW RATE OF 20-INCH-DIAMETER PERMEABILITY TEST SYSTEM May 7986 Engineering and Research Center Deportment of the Interior Bureau of Reclamation Division of Research and Laboratory Services Geotechnical Branch

Transcript of Report No. GR 86-8, Evaluation of Flow Rate of 20 ... · Theflowrateoftheexisting permeability test...

Page 1: Report No. GR 86-8, Evaluation of Flow Rate of 20 ... · Theflowrateoftheexisting permeability test apparatus (usingstraight tees)allowsmeasurement ofcoefficients ofhydraulic conductivity

EVALUATION OF FLOW RATE OF 20-INCH-DIAMETER PERMEABILITY TEST SYSTEM

M a y 7986 Engineering a n d Research Center

Deportment of the Interior Bureau of Reclamation Division of Research and

Laboratory Services Geotechnical Branch

Page 2: Report No. GR 86-8, Evaluation of Flow Rate of 20 ... · Theflowrateoftheexisting permeability test apparatus (usingstraight tees)allowsmeasurement ofcoefficients ofhydraulic conductivity

AUG - 7 '86 7-2090 (4-81) Bureau oi Reclamation TECHNICAL REPORT STANDARD T ITLE PAGE

Bureau of

Evaluation of Flow Rate of 20-Inch-Diameter Permeability Test System

May 1986 6. P E R F O R M I N G O R G A N I Z A T I O N C O D E

I 9. P E R F O R M I N G O R G A N I Z A T I O N N A M E A N D ADDRESS 10. WORK U N I T NO.

J

Bureau of Reclamation Engineering and Research Center Denver, CO 80225

7. AUTHOR^)

Traver E. Metcalf, Jr.

11. C O N T R A C T OR G R A N T NO.

13. T Y P E O F R E P O R T A N D P E R I O D I

8. P E R F O R M I N G O R G A N I Z A T I O N R E P O R T NO.

GR-86-8

12. S P O N S O R I N G A G E N C Y N A M E A N D ADDRESS

I Microfiche and/or hard copy available at the E&R Center, Denver, Colorado I

C O V E R E D I Same

Editor:RDM(c)

16. A B S T R A C T

14. SPONSORING A G E N C Y C O D E

DlBR

Laboratory permeability tests on soils containing gravel that were performed using desig- nation E-14 in the Earth Manual ("Permeability and Settlement of Soil Containing Gravel") showed what appeared to be inconsistent results when coefficients of hydraulic conductivity were determined at flow rates approaching the hydraulic conductivity limits of the test system. An evaluation of the flow rate of the test equipment showed a nonlinear flow rate with increasing hydraulic head. The evaluation identified inadequacies in the existing equip- ment and provided a method for evaluating the reliability of test results when the hydraulic conductivity of the soil approaches the hydraulic conductivity limit of the test system.

15. S U P P L E M E N T A R Y N O T E S

1 7 . K E Y WORDS A N D D O C U M E N T A N A L Y S I S 1 a . D E S C R I P T O R S - - 'flow rate/ *permeability/ soil settlement/ gravel/ coefficients of hy- draulic conductivity/ hydraulic gradients

c . C O S A T I F i e l d / G r o u p 08M C O W R R : 0808.1 SRIM:

18. D I S T R I B U T I O N S T A T E M E N T 19. S E C U R I T Y C L A S S (THIS R E P O R T )

U N C L A S S I F I E D 20. S E C U R I T Y CLASS

( T H I S PAGE)

2 1 . NO. O F PAGES

14 2 2 . P R I C E

Page 3: Report No. GR 86-8, Evaluation of Flow Rate of 20 ... · Theflowrateoftheexisting permeability test apparatus (usingstraight tees)allowsmeasurement ofcoefficients ofhydraulic conductivity

EVALUATION OF FLOW RATE OF 20-INCH-DIAMETER

PERMEABILITY TEST SYSTEM

by

Traver E. Metcalf, Jr.

Geotechnical Branch Division of Research and Laboratory Services

Engineering and Research Center Denver, Colorado

May 1986

UNITED STATES DEPARTMENT OF THE INTERIOR * BUREAU OF RECLAMATION

Page 4: Report No. GR 86-8, Evaluation of Flow Rate of 20 ... · Theflowrateoftheexisting permeability test apparatus (usingstraight tees)allowsmeasurement ofcoefficients ofhydraulic conductivity

As the Nation's principal conservation agency, the Department of theInterior has responsibility for most of our nationally owned publiclands and natural resources. This includes fostering the wisest use ofour land and water resources, protecting our fish and wildlife, preserv-ing the environmental and cultural values of our national parks andhistorical places, and providing for the enjoyment of life through out-door recreation. The Department assesses our energy and mineralresources and works to assure that their development is in the bestinterests of all our people. The Department also has a major respon-sibility for American Indian reservation communities and for peoplewho live in Island Territories under U.S. Administration.

The information contained in this report regarding commercial prod-ucts or firms may not be used for advertising or promotional purposesand is not to be construed as an endorsement of any product or firmby the Bureau of Reclamation.

Page 5: Report No. GR 86-8, Evaluation of Flow Rate of 20 ... · Theflowrateoftheexisting permeability test apparatus (usingstraight tees)allowsmeasurement ofcoefficients ofhydraulic conductivity

CONTENTS

Introduction """"""'"

Conclusions... . . . . ... . . . .. . . . ... . . . ... . . . . . . . ... . . . . . . . . . . . . . . . . . .. . . . . . . . ... .. . . . . .. . . . . ... . . . ... . . .....

Discussion """""""Results.. . . . . . .. . . . . ... . . . . .. . . . .. . . . ... . .

"". .. . . . . . . . .

'".. . . . . . .. . . . . . ... . . . . . . . . . ... . . . ....

Test equipment capacity..........................................................................................................

Bibliography """","""""""""""""""'"

Table

Figure

TABLES

12

Flow rates, mLjs, for configurations 1, 2, and 8, using reduction tees and straight tees..........Equivalent coefficients of hydraulic conductivity ""'" .....

FIGURES

12345

6

Permeability test apparatus.................................................................................................Flow rate of 20-inch-diameter permeability test equipment (reduction tees)

""""""""""""""Straight tee and reduction tee """"""""""""""""""""""

....

Flow rate of 20-inch-diameter permeability test equipment (straight tees)...............................Comparison of decreases in flow rate of partial systems (configuration 2) using reduction tees

and straight tees............................................................................................................Comparison of decreases in flow rates of complete systems (configuration 8) using

reduction tees and straight tees ""'" """"""""""" ......

Comparison of equipment flow rates with soil test results.....................................................Comparison of flow rates of complete systems (configuration 8) using reduction tees and

straight tees..................................................................................................................

78

iii

Page

236

6

46

789

10

11

1213

14

Page 6: Report No. GR 86-8, Evaluation of Flow Rate of 20 ... · Theflowrateoftheexisting permeability test apparatus (usingstraight tees)allowsmeasurement ofcoefficients ofhydraulic conductivity
Page 7: Report No. GR 86-8, Evaluation of Flow Rate of 20 ... · Theflowrateoftheexisting permeability test apparatus (usingstraight tees)allowsmeasurement ofcoefficients ofhydraulic conductivity

INTRODUCTION

Laboratory permeability tests on soils containing gravel that were performed using designation E-

14 in the Earth Manua/[1]* ("Permeability and Settlement of Soil Containing Gravel") showed what

appeared to be inconsistent results when coefficients of hydraulic conductivity were determined

at flow rates approaching the hydraulic conductivity limit of the test system. Although this behavior

was noted before, the specific reasons for the inconsistency were not investigated or documented.

The primary problem with the test data appears in the form of decreasing calculated coefficients

of hydraulic conductivity as the hydraulic gradient is increased. Although this appears unreasonable,

it occurs because the test system operates at a flow rate where a linear flow rate versus hydraulic

head relationship does not exist because of the test equipment configuration. To illustrate this

behavior, a brief evaluation of the flow rate of the test equipment was performed, and the results

were compared with results from an actual permeability test. This information was useful in iden-

tifying inadequacies in the existing test apparatus, and it provides the basis for guidelines used

to evaluate the results of permeability tests.

CONCLUSIONS

The flow rate of the test apparatus defines the maximum coefficients of hydraulic conductivity

that can be measured for any soil. Because the flow rate of the test equipment does not increase

proportionally with increasing hydraulic gradient (hydraulic head). it is not possible to obtain con-

sistent coefficients of hydraulic conductivity with increasing hydraulic gradients when the soil

permeability exceeds the flow rate of the test system under the highest hydraulic gradient tested.

Therefore, the flow rate of the test system under various hydraulic gradients can be used to (1)

establish the validity of test data and (2) serve as an indicator if meaningful data will be provided

by continuing the test.

The flow rate of the existing permeability test apparatus (using straight tees) allows measurement

of coefficients of hydraulic conductivity up to approximately 30,000 ftfyr (3 X 10-2 cm/s). The

test equipment, including the constant head supply tank, water supply system, and the permea-

meter cylinder, would have to be completely redesigned to accommodate flow rates for measuring

significantly larger coefficients of hydraulic conductivity.

. Numbers in brackets refer to entries in the bibliography.

Page 8: Report No. GR 86-8, Evaluation of Flow Rate of 20 ... · Theflowrateoftheexisting permeability test apparatus (usingstraight tees)allowsmeasurement ofcoefficients ofhydraulic conductivity

DISCUSSION

Flow rate characteristics of the test apparatus were determined to identify (1) flow rates of thevarious components of the test apparatus and (2) the impact of flow rate on the coefficients of

hydraulic conductivity calculated from the measured flow rates.

The 20-inch-diameter permeability equipment used in this study is shown on figure 1. The flow

rate of the system was evaluated progressively, beginning with only the constant head water

supply tank and a length of flexible tubing, and ending with the entire test system, including all

tubing, fittings, and equipment involved in measuring the flow rate of a soil (using a spacing ring

instead of a soil specimen). The components of the system were progressively tested in the

configurations listed below:

1. Head tank plus 53% inches of flexible tubing (Y2-inch i.d.)

2. Plus tee No.1

3. Plus 36 inches of flexible tubing (Y2-inch i.d.)

4. Plus tee No.2 and two pieces of flexible tubing, each 47 inches long (%-inch i.d.)

5. Plus permeameter cylinder

6. Plus pea gravel porous base

7. Plus top porous stone plus loading plate(Includes components 1 through 6 and 7)

8. Plus top porous gravel plus loading plate(Includes components 1 through 6 and 8)

The maximum hydraulic flow rate though the system was desired. Therefore, a pea gravel base

was used instead of a porous stone base because gravel has greater conductivity.

The flow rate of the test system was measured progressively. Test data were recorded, and the

flow rate was determined in milliliters per second.

The flow rate of the test system was measured at hydraulic heads of 0.75, 1.50, 2.25, and 3.0

feet; which correspond with hydraulic gradients of 1, 2, 3, and 4, assuming a 9-inch-high soil

specimen is actually tested in the system.

2

Page 9: Report No. GR 86-8, Evaluation of Flow Rate of 20 ... · Theflowrateoftheexisting permeability test apparatus (usingstraight tees)allowsmeasurement ofcoefficients ofhydraulic conductivity

The flow rate versus hydraulic gradient plots for configurations 1, 2, 3, 4, 5, 7, and 8 are shown

on figure 2.

Results

The flow rate versus hydraulic gradient test data show a significant decrease in flow rate when

the first tee is inserted into the system (configuration 2, fig. 2). Results also show additional

decreases in the flow rate when the second tee, tubing, permeameter cylinder, porous media,

and loading plate are added to the system. However, the impact of each of these items on the

flow rate of the test system is very small compared with the decrease associated with the first

tee.

When the head tank, plumbing components, and permeameter cylinders of all other test apparatus

were inspected, it was discovered that these systems used a different type of tee from the one

used in the apparatus being evaluated. The test apparatus being evaluated used plastic insert

(tapered) tees that had an orifice of approximately Va inch diameter (this tee is referred to as a

reduction tee). However, the other apparatus used V2-inch-Ld. copper pipe tees with short sections

of pipe soldered to each branch (this tee is referred to as a straight tee). The two types of tees

are shown on figure 3.

The impact of the straight tee on the flow rate was determined by replacing the reduction tees

in the original system with straight tees and again progressively measuring the flow rate of the

system. The results of these tests (fig. 4) also show a reduction in flow rate upon addition of the

first tee (configuration 2), but the magnitude of the reduction is significantly less. Additional de-

creases occur with the addition of the remaining tee, tubing, permeameter cylinder, porous media,

and loading plates. Although each of these additional decreases is greater than the corresponding

loss in the system with the reduction tee (because of higher flow rates and a correspondingly

higher friction loss), the decrease in flow rate for a complete system (configurations 7 or 8) using

the straight tees is significantly less than that for a complete system using reduction tees. The

decreases in flow rates are shown on figure 5, for a partial system (configuration 2), and figure

6, for a complete system (configuration 8), and are summarized in table 1.

The flow rate of the test system decreased approximately 80 percent when the reduction tee

was added to the head tank and flexible tubing. However, the flow rate of the test system de-

creased only about 20 percent when the straight tee was added to the system. Although adding

components further decreased the flow rate of the system, the flow rate of the complete system

3

Page 10: Report No. GR 86-8, Evaluation of Flow Rate of 20 ... · Theflowrateoftheexisting permeability test apparatus (usingstraight tees)allowsmeasurement ofcoefficients ofhydraulic conductivity

Hydraulic gradient

1 2 3 4

Head tank plus tubing (configuration 1) 107.5 164.2 205.0 239.5

Head tank and tubing plus tee No.1 (reduction) 24.4 33.7 43.4 51.7(configuration 2) (22.7)* (20.5) (21.2) (21.6)

Head tank plus complete system (reduction tee) 17.5 27.5 34.6 39.6(configuration 8) (16.3) (16.8) (16.9) (16.5)

Head tank and tubing plus tee No.1 (straight) 90.6 131.5 163.8 190.1(configuration 2) (84.3) (80.1) (79.9) (79.4)

Head tank plus complete system (straight tee) 50.0 76.0 101.4 121.4(configuration 8) (46.5) (46.3) (49.4) (50.5)

.Numbers in parentheses indicate percent of configuration 1 flow.

Table 1. - Flow rates, mL/s, for configurations 1, 2, and 8, using reduction tees and straight tees.

using the straight tee was approximately 50 percent of initial capacity, much more than the ap-

proximately 17 percent for the complete system using the reduction tee.

The impact of the flow rate of the test system on calculated coefficients of hydraulic conductivity

can be illustrated using actual test results.

A permeability test was performed on soil from Clark Canyon Dam using the same head tank,

plumbing (with reduction tees), and permeameter cylinder used in the evaluation. A specimen from

sample No. 20A-46 was placed in the cylinder on a porous gravel base and loaded using a porous

stone attached to a loading plate. The results of this soil test are shown on figure 7 in the plot

designated "test flow"; the plot of the equipment flow rate is designated "equipment flow." The

line designated "theoretical flow" represents the flow rate required for a coefficient of hydraulic

conductivity, at hydraulic gradients of 2 and 4, equivalent to that measured under the hydraulic

gradient of 1.

Figure 7 clearly shows that the results obtained for the Clark Canyon Dam sample were influenced

by the flow rate capacity of the test equipment. The results also show decreasing calculated

coefficients of hydraulic conductivity with increasing hydraulic gradients. For these results, it is

appropriate to report only the coefficient of hydraulic conductivity, 9,290 ftfyr obtained under the

hydraulic gradient of 1, because under hydraulic gradients of 2 and 4, the measured coefficients

of hydraulic conductivity were 7,020 and 4,920 ftfyr, respectively.

4

Page 11: Report No. GR 86-8, Evaluation of Flow Rate of 20 ... · Theflowrateoftheexisting permeability test apparatus (usingstraight tees)allowsmeasurement ofcoefficients ofhydraulic conductivity

The decrease in the calculated coefficient of hydraulic conductivity with increasing hydraulic gra-

dient results from the nonlinear flow rate of the test system caused by friction losses. Since the

flow rate of the test system does not increase proportionally with the hydraulic gradient, the

coefficient of hydraulic conductivity of the soil, as calculated using Darcy's law, decreases as

shown below:

q = kia (1)

where:

q = flow rate (volume per time),

k = coefficient of hydraulic conductivity (length per time),

I = hydraulic gradient, and

a = cross-sectional area through which flow occurs (length squared).

. h1= -

I(2)

where:

h = hydraulic head loss (length), and

I = length of seepage path (length).

Thus, equation (1) may be rewritten:

q = k (~) a (3)

Therefore:

k = (~) (~)I

where - is constant for a particular test configuration.a

Since k is proportional to q/ h, and q/ h exhibits a decreasing slope with increasing h, calculated

values of k decrease with increasing h. To provide guidelines for evaluating hydraulic conductivity

coefficients determined using this equipment and to demonstrate the magnitude of restriction

caused by the reduction fee, flow rates for the total test system (configuration 8 for both cases)

are shown on figure 8. The calculated coefficient of hydraulic conductivity (expressed in ftfyr) for

5

Page 12: Report No. GR 86-8, Evaluation of Flow Rate of 20 ... · Theflowrateoftheexisting permeability test apparatus (usingstraight tees)allowsmeasurement ofcoefficients ofhydraulic conductivity

the system is shown in parentheses next to each maximum flow rate at each gradient. These

results are summarized in table 2.

Table 2. - Equivalent coefficients of hydraulic conductivity.

Hydraulic gradient,h/I

1.02.04.0

Reduction tee,ftfyr

10,2108,0205,690

Straight tee,ft/yr

29,17022, 16517,390

Using reduction tees in the water supply plumbing yielded a system flow rate that was approxi-

mately one-third that of the system with straight tees.

The flow rate of the system can be used as a guide to determine whether or not the hydraulic

gradient should be increased after testing is completed under a hydraulic gradient of 1. If the

coefficient of hydraulic conductivity measured under a hydraulic gradient of 1 approaches or equals

that calculated for the equipment flow rate, there is no reason to continue testing using higher

hydraulic gradients.

The flow rate of test equipment should be determined for each complete test system for all

hydraulic gradients under which a specimen will be tested. This flow rate calibration should be

performed whenever a component of the test system is changed, semiannually, or each time the

permeability test is performed. It should guide the test operator in performing the test for proper

duration and test conditions, as described in the previous paragraph.

Test Equipment Capacity

The maximum coefficient of hydraulic conductivity that can be measured using straight tees ap-

proaches 30,000 ftfyr (3.0 X 10-2 cm/s). This serves as the limit of measurable hydraulic con-

ductivity with this equipment. To measure coefficients of hydraulic conductivity above 30,000 ftl

yr, the water supply and test cylinder equipment would have to be redesigned.

BIBLIOGRAPHY

[1] Earth Manual, 2d ed., reprint, Bureau of Reclamation, pp. 505-508, U.S. Government Printing Office,Washington, D.C., 1980.

6

Page 13: Report No. GR 86-8, Evaluation of Flow Rate of 20 ... · Theflowrateoftheexisting permeability test apparatus (usingstraight tees)allowsmeasurement ofcoefficients ofhydraulic conductivity

CONSTANT HEAD TANKC.L.~.

-

TEE NO. I53-1/2" FLEXIBLE TUBING

36" FLEXIBLE TUBING

CLAMP TEE NQ 2

47" FLEXIBLE TUBING

NOTE: ALL TUBING IS 1/2- ID

PERMEANT WATER SUPPLY SYSTEM

rSPELEN

DIRECTIONI

WATER SUPPLY OF FLOW

INLET\ ::'","",:: ,'PORO,US',BASE','.. >,',':",>:

---~~~-~~~~~~~~~-~-----

LOADING PLATE -OVERFLOW

" :', ' : "', ', ',', .. .POROUS TOP

'"','

" "",'.',:

r

WA TER SUPPLYINLET

-- --- -- --- -----

BASE PLATE

PERMEAMETER CYCLI NDER

Figure 1. - Permeability test apparatus.

7

Page 14: Report No. GR 86-8, Evaluation of Flow Rate of 20 ... · Theflowrateoftheexisting permeability test apparatus (usingstraight tees)allowsmeasurement ofcoefficients ofhydraulic conductivity

(JOJv.I

"--.JE

'-J

Wl-CEa::

~00 0-.Ju..

250

II~ -

I----~

------- II I-I !

200

II

!

150

100

---------::: :: ~ I ----------- ------.-

:::=.-- ----.

~-

50

00 1.5 2 2.5

HYDRAULIC GRADIENT.5 3 3.5

Figure 2. - Flow rate of 2Q-inch-diameter permeability test equipment (reduction tees).

LEGEND

0 Configuration 1

X Configuration 2

* Configuration!

+ Configuration 4

1 Confiquration 5

2 Configuration 7

3 Configuration 8

4

Page 15: Report No. GR 86-8, Evaluation of Flow Rate of 20 ... · Theflowrateoftheexisting permeability test apparatus (usingstraight tees)allowsmeasurement ofcoefficients ofhydraulic conductivity

Figure 3. - Straight tee and reduction tee.

Page 16: Report No. GR 86-8, Evaluation of Flow Rate of 20 ... · Theflowrateoftheexisting permeability test apparatus (usingstraight tees)allowsmeasurement ofcoefficients ofhydraulic conductivity

LEGEND

2500 Configuration 1

X Configuration 2

200 * Configuration 3

u + Configuration 4Q)

'"'\.1 Configuration 5-.J

E'<oJ 150

w 2 Configuration 7I-a:

//0:::3 Configuration 80 3:

0-.J 100u...

/50

~_.

00 .5 1.5 2 2.5

HYDRAULIC GRADIENT

3 3.5 4

Figure 4. - Flow rate of 2D-inch-diameter permeability test equipment (straight tees).

Page 17: Report No. GR 86-8, Evaluation of Flow Rate of 20 ... · Theflowrateoftheexisting permeability test apparatus (usingstraight tees)allowsmeasurement ofcoefficients ofhydraulic conductivity

ro.UQ)

'"'"-IE

'\J

WI-a:0:=....

....~0-ILL

250

200

150

100

50

00

~

~

~

/'

///

'/1

. .. . . . . . . . . . . . .'

...,

""'--'

----

.. ,-.-

3.5

--

LEGEND

0CONFIGURATION 1

x ,

CONFIGURATION2 'R'

*CONFIGURATION2 's'

4

Figure 5. - Comparison of decreases in flow rates of partial systems (configuration 2) using reduction tees and straight tees.

. . . . . . . . . . . .

.5 1.5 2 2.5

HYDRAULIC GRADIENT3

Page 18: Report No. GR 86-8, Evaluation of Flow Rate of 20 ... · Theflowrateoftheexisting permeability test apparatus (usingstraight tees)allowsmeasurement ofcoefficients ofhydraulic conductivity

,..,0Q)

0

"--.JE

'"'W

~a:0::

~~N0-.Ju..

LEGEND

251120CONfIGURATION 1

XCONfIGURATION B 'R'

2112112 * - - -CONfIGURATION B 's'

----112

112 .5 1.5 2 2.5 3 3.5 4HYDRAULIC GRADIENT

15112

------

1112112 ---------

---5112

Figure 6. - Comparison of decreases in flow rate of complete systems (configuration 8) using reduction tees and straight tees.

-,

Page 19: Report No. GR 86-8, Evaluation of Flow Rate of 20 ... · Theflowrateoftheexisting permeability test apparatus (usingstraight tees)allowsmeasurement ofcoefficients ofhydraulic conductivity

,....

uQ)£I)

"--.JE

"-'W.....a::0:::

3:0

(..) -.JLL

80

70

60

50

40

30

20

10

00

-----:/" (9,290)

---(4,920)

3.5

LEGEND

0THEORETICAL FLOW

XEQUIPMENT FLOW

* ---TEST FLOW

4

NOTE: Numbers in parentheses are calculated coefficients of hydraulic conductivity in feet per year.

~

.5 1.5 2 2.5HYDRAULIC GRADIENT

3

Figure 7. - Comparison of equipment flow rates with soil test results.

Page 20: Report No. GR 86-8, Evaluation of Flow Rate of 20 ... · Theflowrateoftheexisting permeability test apparatus (usingstraight tees)allowsmeasurement ofcoefficients ofhydraulic conductivity

LEGEND

1400CONfIGURATION B 'R'

(17,390) X120 CONfIGURATION B '5'

-----

'"' (21,970) -----0 10011)

~/""

"..JE

80 /""

.JJ- (22,165):I:

/""~3:

0 60/""... ..J

~..L.(29,170)

40 .L5 ~Ql

/

20

00 .5 1.5 2 2.5

HYDRAULIC GRADIENT

3 3.5 4

NOTE: Numbers in parentheses are calculated coefficients of hydraulic conductivity in feet per year.

Figure 8. - Comparison of flow rates of complete systems (configuration 8) using reduction tees and straight tees.

Page 21: Report No. GR 86-8, Evaluation of Flow Rate of 20 ... · Theflowrateoftheexisting permeability test apparatus (usingstraight tees)allowsmeasurement ofcoefficients ofhydraulic conductivity

Mission of the Bureau of Reclamation

The Bureau of Reclamation of the U.S. Department of the Interior is responsible for the development and conservation of the Nation's water resources in the Western United States.

The Bureau's original purpose "to provide for the reclamation of arid and semiarid lands in the West" today covers a wide range of interre- lated functions. These include providing municipal and industrial water supplies; hydroelectric power generation; irrigation water for agricul- ture; water quality improvement; flood control; river navigation; river regulation and control; fish and wildlife enhancement; outdoor recrea- tion; and research on water-rela ted design, construction, materials, atmo~heric management, and wind and solar power.

Bureau programs most frequently are the result of close cooperation with the U.S. Congress, other Federal agencies, States, local govern- men ts, academic institutions, water-user organizations, and other concerned groups.

for Sale." I t describes some of the technical publications currently available, their cost, and how to order them. The pamphlet can be obtained upon request from the Bureau of Reclamation, Attn D-822A,