![Page 1: Replacing an Existing Elevated Storage Tank on the Same Site...April 13, 2015 Eric Williams, PE 2015 North Carolina Spring Conference NC AWWA-WEA Replacing an Existing Elevated Storage](https://reader033.fdocuments.us/reader033/viewer/2022052007/601af1761040410fb86604d5/html5/thumbnails/1.jpg)
April 13, 2015Eric Williams, PE
2015 North Carolina Spring ConferenceNC AWWA-WEA
Replacing an Existing Elevated
Storage Tank on the Same Site
![Page 2: Replacing an Existing Elevated Storage Tank on the Same Site...April 13, 2015 Eric Williams, PE 2015 North Carolina Spring Conference NC AWWA-WEA Replacing an Existing Elevated Storage](https://reader033.fdocuments.us/reader033/viewer/2022052007/601af1761040410fb86604d5/html5/thumbnails/2.jpg)
Existing Facilities
Maintenance Issues
Tank Alternatives
Challenges
![Page 3: Replacing an Existing Elevated Storage Tank on the Same Site...April 13, 2015 Eric Williams, PE 2015 North Carolina Spring Conference NC AWWA-WEA Replacing an Existing Elevated Storage](https://reader033.fdocuments.us/reader033/viewer/2022052007/601af1761040410fb86604d5/html5/thumbnails/3.jpg)
Bid Challenges
Tank Construction
Tank Demolition
Construction Costs
![Page 4: Replacing an Existing Elevated Storage Tank on the Same Site...April 13, 2015 Eric Williams, PE 2015 North Carolina Spring Conference NC AWWA-WEA Replacing an Existing Elevated Storage](https://reader033.fdocuments.us/reader033/viewer/2022052007/601af1761040410fb86604d5/html5/thumbnails/4.jpg)
Project Location
![Page 5: Replacing an Existing Elevated Storage Tank on the Same Site...April 13, 2015 Eric Williams, PE 2015 North Carolina Spring Conference NC AWWA-WEA Replacing an Existing Elevated Storage](https://reader033.fdocuments.us/reader033/viewer/2022052007/601af1761040410fb86604d5/html5/thumbnails/5.jpg)
Project Location
![Page 6: Replacing an Existing Elevated Storage Tank on the Same Site...April 13, 2015 Eric Williams, PE 2015 North Carolina Spring Conference NC AWWA-WEA Replacing an Existing Elevated Storage](https://reader033.fdocuments.us/reader033/viewer/2022052007/601af1761040410fb86604d5/html5/thumbnails/6.jpg)
01 Existing Facilities
![Page 7: Replacing an Existing Elevated Storage Tank on the Same Site...April 13, 2015 Eric Williams, PE 2015 North Carolina Spring Conference NC AWWA-WEA Replacing an Existing Elevated Storage](https://reader033.fdocuments.us/reader033/viewer/2022052007/601af1761040410fb86604d5/html5/thumbnails/7.jpg)
2 Inch -12 Inch Water Lines
Materials Including PVC, Ductile Iron and Asbestos Cement
3 Master Meters
2 Elevated Storage Tanks
Existing Facilities
![Page 8: Replacing an Existing Elevated Storage Tank on the Same Site...April 13, 2015 Eric Williams, PE 2015 North Carolina Spring Conference NC AWWA-WEA Replacing an Existing Elevated Storage](https://reader033.fdocuments.us/reader033/viewer/2022052007/601af1761040410fb86604d5/html5/thumbnails/8.jpg)
Constructed in 1998
Capacity – 250,000 Gallons
Style – Single Pedestal
Contractor – Brown Steel Contractors
West End Elevated Storage Tank
![Page 9: Replacing an Existing Elevated Storage Tank on the Same Site...April 13, 2015 Eric Williams, PE 2015 North Carolina Spring Conference NC AWWA-WEA Replacing an Existing Elevated Storage](https://reader033.fdocuments.us/reader033/viewer/2022052007/601af1761040410fb86604d5/html5/thumbnails/9.jpg)
Constructed in 1973
Capacity – 200,000 Gallons
Style – Leg
Overflow Elevation – Approximately
2.2 Feet Lower than West End Tank
Contractor – Brown Steel Contractors
East End Elevated Storage Tank
![Page 10: Replacing an Existing Elevated Storage Tank on the Same Site...April 13, 2015 Eric Williams, PE 2015 North Carolina Spring Conference NC AWWA-WEA Replacing an Existing Elevated Storage](https://reader033.fdocuments.us/reader033/viewer/2022052007/601af1761040410fb86604d5/html5/thumbnails/10.jpg)
02 Maintenance Issues
![Page 11: Replacing an Existing Elevated Storage Tank on the Same Site...April 13, 2015 Eric Williams, PE 2015 North Carolina Spring Conference NC AWWA-WEA Replacing an Existing Elevated Storage](https://reader033.fdocuments.us/reader033/viewer/2022052007/601af1761040410fb86604d5/html5/thumbnails/11.jpg)
Tank in Need of Painting
Repainting would Require Complete Shrouding
Drip Line of Tank Extended Over 2 Adjacent Properties
East End Storage Tank Maintenance Issues
![Page 12: Replacing an Existing Elevated Storage Tank on the Same Site...April 13, 2015 Eric Williams, PE 2015 North Carolina Spring Conference NC AWWA-WEA Replacing an Existing Elevated Storage](https://reader033.fdocuments.us/reader033/viewer/2022052007/601af1761040410fb86604d5/html5/thumbnails/12.jpg)
03 Tank Alternatives
![Page 13: Replacing an Existing Elevated Storage Tank on the Same Site...April 13, 2015 Eric Williams, PE 2015 North Carolina Spring Conference NC AWWA-WEA Replacing an Existing Elevated Storage](https://reader033.fdocuments.us/reader033/viewer/2022052007/601af1761040410fb86604d5/html5/thumbnails/13.jpg)
Repaint and Repair Existing Tank
oCosts were Estimated at $500,000-$600,000 (Lead Based Paint)
oTank Would Still Be 40+ Years Old
Build a New Tank
oCan Increase Capacity
oCan Match West End Overflow Elevation
oCan Match Tank Style
oFuture Maintenance Less Costly
East End Storage Tank Alternatives
![Page 14: Replacing an Existing Elevated Storage Tank on the Same Site...April 13, 2015 Eric Williams, PE 2015 North Carolina Spring Conference NC AWWA-WEA Replacing an Existing Elevated Storage](https://reader033.fdocuments.us/reader033/viewer/2022052007/601af1761040410fb86604d5/html5/thumbnails/14.jpg)
04 Challenges
![Page 15: Replacing an Existing Elevated Storage Tank on the Same Site...April 13, 2015 Eric Williams, PE 2015 North Carolina Spring Conference NC AWWA-WEA Replacing an Existing Elevated Storage](https://reader033.fdocuments.us/reader033/viewer/2022052007/601af1761040410fb86604d5/html5/thumbnails/15.jpg)
New Tank Construction
Close Proximity of Homes
Pile Installation
Painting
Telecommunications Facilities
Demolition of Existing Tank
Resort/Vacation Destination –
Construction Schedule
Restrictions
Challenges
![Page 16: Replacing an Existing Elevated Storage Tank on the Same Site...April 13, 2015 Eric Williams, PE 2015 North Carolina Spring Conference NC AWWA-WEA Replacing an Existing Elevated Storage](https://reader033.fdocuments.us/reader033/viewer/2022052007/601af1761040410fb86604d5/html5/thumbnails/16.jpg)
Challenges - Tank Site
![Page 17: Replacing an Existing Elevated Storage Tank on the Same Site...April 13, 2015 Eric Williams, PE 2015 North Carolina Spring Conference NC AWWA-WEA Replacing an Existing Elevated Storage](https://reader033.fdocuments.us/reader033/viewer/2022052007/601af1761040410fb86604d5/html5/thumbnails/17.jpg)
05 Bid Challenges
![Page 18: Replacing an Existing Elevated Storage Tank on the Same Site...April 13, 2015 Eric Williams, PE 2015 North Carolina Spring Conference NC AWWA-WEA Replacing an Existing Elevated Storage](https://reader033.fdocuments.us/reader033/viewer/2022052007/601af1761040410fb86604d5/html5/thumbnails/18.jpg)
Planned to Bid Tank Construction and Tank Demolition Separately
Only One Bid Received on Bid Day
Only One Bid Received on the Rescheduled Bid Day
Bid not Submitted by a Tank Contractor – A. C. Schultes
Bid Received Exceeded Budget
Able to Negotiate a Lower Price
Negotiations Included Adding Tank Demolition
Bid Challenges
![Page 19: Replacing an Existing Elevated Storage Tank on the Same Site...April 13, 2015 Eric Williams, PE 2015 North Carolina Spring Conference NC AWWA-WEA Replacing an Existing Elevated Storage](https://reader033.fdocuments.us/reader033/viewer/2022052007/601af1761040410fb86604d5/html5/thumbnails/19.jpg)
06 Tank Construction
![Page 20: Replacing an Existing Elevated Storage Tank on the Same Site...April 13, 2015 Eric Williams, PE 2015 North Carolina Spring Conference NC AWWA-WEA Replacing an Existing Elevated Storage](https://reader033.fdocuments.us/reader033/viewer/2022052007/601af1761040410fb86604d5/html5/thumbnails/20.jpg)
Water Line Installation
12-Inch Water Line
Design was to Cut In New Tee
Existing Isolation Valve Would not
Hold
Tank Construction
![Page 21: Replacing an Existing Elevated Storage Tank on the Same Site...April 13, 2015 Eric Williams, PE 2015 North Carolina Spring Conference NC AWWA-WEA Replacing an Existing Elevated Storage](https://reader033.fdocuments.us/reader033/viewer/2022052007/601af1761040410fb86604d5/html5/thumbnails/21.jpg)
Foundation Installation
Driven 12-Inch Steel H Piles
Minimum Depth Required - 40 Feet
Monitored Vibration at Adjacent Homes
Noise Restrictions (8:00 am – 8:00 pm)
Pile Cap – 4 Feet Thick by 2.5 Feet
Wide
24 – 2” Anchor Bolts by 3 Feet 4 Inches
Long (To Extend 7 Inches Above
Concrete)
Tank Construction
![Page 22: Replacing an Existing Elevated Storage Tank on the Same Site...April 13, 2015 Eric Williams, PE 2015 North Carolina Spring Conference NC AWWA-WEA Replacing an Existing Elevated Storage](https://reader033.fdocuments.us/reader033/viewer/2022052007/601af1761040410fb86604d5/html5/thumbnails/22.jpg)
Structure by Caldwell Tanks
Challenges
oClose Proximity of Homes
oTotal Site – Less than ½ Acre
oStorage Space for Steel
Components
oExisting Tank
oTelecommunications Structures
Tank Construction
![Page 23: Replacing an Existing Elevated Storage Tank on the Same Site...April 13, 2015 Eric Williams, PE 2015 North Carolina Spring Conference NC AWWA-WEA Replacing an Existing Elevated Storage](https://reader033.fdocuments.us/reader033/viewer/2022052007/601af1761040410fb86604d5/html5/thumbnails/23.jpg)
Structure
Single Pedestal
Complaints/Damage to
Private Property
Tank Construction
![Page 24: Replacing an Existing Elevated Storage Tank on the Same Site...April 13, 2015 Eric Williams, PE 2015 North Carolina Spring Conference NC AWWA-WEA Replacing an Existing Elevated Storage](https://reader033.fdocuments.us/reader033/viewer/2022052007/601af1761040410fb86604d5/html5/thumbnails/24.jpg)
Painting
Shrouding Required –
Tightly Woven Nylon
Windy Conditions –
15 mph Maximum
Summer Season
Restrictions
Tank Construction
![Page 25: Replacing an Existing Elevated Storage Tank on the Same Site...April 13, 2015 Eric Williams, PE 2015 North Carolina Spring Conference NC AWWA-WEA Replacing an Existing Elevated Storage](https://reader033.fdocuments.us/reader033/viewer/2022052007/601af1761040410fb86604d5/html5/thumbnails/25.jpg)
Shrouding
Outriggers
Extensive Cabling
Equipment at Base of Tank for Raising and
Lowering Shroud
Tank Construction
![Page 26: Replacing an Existing Elevated Storage Tank on the Same Site...April 13, 2015 Eric Williams, PE 2015 North Carolina Spring Conference NC AWWA-WEA Replacing an Existing Elevated Storage](https://reader033.fdocuments.us/reader033/viewer/2022052007/601af1761040410fb86604d5/html5/thumbnails/26.jpg)
Paint by Tnemec
Interior (Dry) – 2 Coat System
o Shop Prime – 5.0 mils Series N-140 Epoxy
o Stripe Coat – 5.0 mils Series N-140 Epoxy – For all Seams
and Abraded Areas
o Finish Coat – 5.0 mils Series N-140 Epoxy – Stripe Coat
then Full Coat
Interior (Wet) – 3 Coat System
o Shop Prime – 3.0 mils Series 94 Hydro-Zinc
o Stripe Coat – 3.0 mils Series 94 Hydro-Zinc – For all
Seams and Abraded Areas
o Finish Coat –
• 5.0 mils Series N-140 Epoxy – Stripe Coat to all Weld Seams,
Edges, Corners, Bolts and Nuts – Tank White
• 5.0 mils Series N140 Epoxy – Beige Color
• 5.0 mils Series N140 Epoxy – Tank White
Tank Construction
![Page 27: Replacing an Existing Elevated Storage Tank on the Same Site...April 13, 2015 Eric Williams, PE 2015 North Carolina Spring Conference NC AWWA-WEA Replacing an Existing Elevated Storage](https://reader033.fdocuments.us/reader033/viewer/2022052007/601af1761040410fb86604d5/html5/thumbnails/27.jpg)
Paint by Tnemec
Exterior – 4 Coat System
o Shop Prime – 3.0 mils Series
94 Zinc Rich Polyurethane
o Stripe Coat – 3.0 mils Series
94 – For all Seams and
Abraded Areas
o Finish Coat – 3 Separate
Coats
• 3.0 mils Series N69 Hi-Build
Epoxy
• 2.0 mils Series 73 Endura Shield
(Polyurethane Enamel)
• 2.5 mils Series 700 Hydroflon
Tank Construction
![Page 28: Replacing an Existing Elevated Storage Tank on the Same Site...April 13, 2015 Eric Williams, PE 2015 North Carolina Spring Conference NC AWWA-WEA Replacing an Existing Elevated Storage](https://reader033.fdocuments.us/reader033/viewer/2022052007/601af1761040410fb86604d5/html5/thumbnails/28.jpg)
Standby Generator for SCADA
Electrical and SCADA Equipment
Discharge Headwall Structure
Altitude Valve
Tank ConstructionTank Components
![Page 29: Replacing an Existing Elevated Storage Tank on the Same Site...April 13, 2015 Eric Williams, PE 2015 North Carolina Spring Conference NC AWWA-WEA Replacing an Existing Elevated Storage](https://reader033.fdocuments.us/reader033/viewer/2022052007/601af1761040410fb86604d5/html5/thumbnails/29.jpg)
Telecommunication Vendors
ATMC/AT&T
Verizon
Town
Communication
Antenna
SCADA Antenna
Tank Construction
Verizon ATMC/AT&T
![Page 30: Replacing an Existing Elevated Storage Tank on the Same Site...April 13, 2015 Eric Williams, PE 2015 North Carolina Spring Conference NC AWWA-WEA Replacing an Existing Elevated Storage](https://reader033.fdocuments.us/reader033/viewer/2022052007/601af1761040410fb86604d5/html5/thumbnails/30.jpg)
Telecommunications
Cabling in Tank
Cabling Continues Through
Access Tube
Tank Construction
![Page 31: Replacing an Existing Elevated Storage Tank on the Same Site...April 13, 2015 Eric Williams, PE 2015 North Carolina Spring Conference NC AWWA-WEA Replacing an Existing Elevated Storage](https://reader033.fdocuments.us/reader033/viewer/2022052007/601af1761040410fb86604d5/html5/thumbnails/31.jpg)
07 Tank Demolition
![Page 32: Replacing an Existing Elevated Storage Tank on the Same Site...April 13, 2015 Eric Williams, PE 2015 North Carolina Spring Conference NC AWWA-WEA Replacing an Existing Elevated Storage](https://reader033.fdocuments.us/reader033/viewer/2022052007/601af1761040410fb86604d5/html5/thumbnails/32.jpg)
Protect
Telecommunications
Structures
Protect Brand New
Tank
Loading of Steel
Components
Tank Demolition
![Page 33: Replacing an Existing Elevated Storage Tank on the Same Site...April 13, 2015 Eric Williams, PE 2015 North Carolina Spring Conference NC AWWA-WEA Replacing an Existing Elevated Storage](https://reader033.fdocuments.us/reader033/viewer/2022052007/601af1761040410fb86604d5/html5/thumbnails/33.jpg)
No Complaints or Damage
During Demolition
Three Days from Start to
Finish
Tank Demolition
![Page 34: Replacing an Existing Elevated Storage Tank on the Same Site...April 13, 2015 Eric Williams, PE 2015 North Carolina Spring Conference NC AWWA-WEA Replacing an Existing Elevated Storage](https://reader033.fdocuments.us/reader033/viewer/2022052007/601af1761040410fb86604d5/html5/thumbnails/34.jpg)
Valve Vault
Other Structures
Tank Demolition
![Page 35: Replacing an Existing Elevated Storage Tank on the Same Site...April 13, 2015 Eric Williams, PE 2015 North Carolina Spring Conference NC AWWA-WEA Replacing an Existing Elevated Storage](https://reader033.fdocuments.us/reader033/viewer/2022052007/601af1761040410fb86604d5/html5/thumbnails/35.jpg)
08 Construction Costs
![Page 36: Replacing an Existing Elevated Storage Tank on the Same Site...April 13, 2015 Eric Williams, PE 2015 North Carolina Spring Conference NC AWWA-WEA Replacing an Existing Elevated Storage](https://reader033.fdocuments.us/reader033/viewer/2022052007/601af1761040410fb86604d5/html5/thumbnails/36.jpg)
Original Budget - $1,400,000
As Bid Without Demolition - $1,574,618
After Negotiations with Demolition -
$1,498,600
Final Cost after Change Orders -
$1,475,038.75
Approximately $35,000 Paid by
Telecommunications Vendors
Construction Costs