telRemote sensors & PA amplifiers
PRODUCT TRAINING PROGRAM
![Page 3: Remote Sensors And Amplifiers](https://reader033.fdocuments.us/reader033/viewer/2022042614/555be688d8b42a33078b4ec7/html5/thumbnails/3.jpg)
Remote sensors & PA amplifiers
![Page 4: Remote Sensors And Amplifiers](https://reader033.fdocuments.us/reader033/viewer/2022042614/555be688d8b42a33078b4ec7/html5/thumbnails/4.jpg)
Mode Symbol Advantages Disadvantages
Thru BeamLong rangeHigh excess gain
Mounting and Cabling on 2 sides
Diffuse Proximity
Mounting of one unit only
Short sensing distanceObject dependent
Background Suppression
Mounting one unit only,Color independent
Short sensing distance
Retro reflective
Mounting one unit onlyReflector, Dirt, Alignment
Retro reflective Pol.
Fibre OpticInaccessible and small placesHigh temperatures
Short sensing rangeInstallation
telRemote sensors & PA amplifiers
OPERATION MODES:
![Page 5: Remote Sensors And Amplifiers](https://reader033.fdocuments.us/reader033/viewer/2022042614/555be688d8b42a33078b4ec7/html5/thumbnails/5.jpg)
telRemote sensors & PA amplifiers
Very small, very compact, sensor dimensions
Easy Alignment in thru beam mode
High penetration power
High Light Immunity
Insensitive to shock and vibrations
IP67 sealing
TELCO’S CORE VALUES
![Page 6: Remote Sensors And Amplifiers](https://reader033.fdocuments.us/reader033/viewer/2022042614/555be688d8b42a33078b4ec7/html5/thumbnails/6.jpg)
telRemote sensors & PA amplifiers
Insensitive to shock and vibrations
![Page 7: Remote Sensors And Amplifiers](https://reader033.fdocuments.us/reader033/viewer/2022042614/555be688d8b42a33078b4ec7/html5/thumbnails/7.jpg)
telRemote sensors & PA amplifiers
High Light Immunity
![Page 8: Remote Sensors And Amplifiers](https://reader033.fdocuments.us/reader033/viewer/2022042614/555be688d8b42a33078b4ec7/html5/thumbnails/8.jpg)
telRemote sensors & PA amplifiers
Easy Alignment in thru beam mode
![Page 9: Remote Sensors And Amplifiers](https://reader033.fdocuments.us/reader033/viewer/2022042614/555be688d8b42a33078b4ec7/html5/thumbnails/9.jpg)
telRemote sensors & PA amplifiers
High penetration power
![Page 10: Remote Sensors And Amplifiers](https://reader033.fdocuments.us/reader033/viewer/2022042614/555be688d8b42a33078b4ec7/html5/thumbnails/10.jpg)
telRemote sensors & PA amplifiers
IP67 sealing
![Page 11: Remote Sensors And Amplifiers](https://reader033.fdocuments.us/reader033/viewer/2022042614/555be688d8b42a33078b4ec7/html5/thumbnails/11.jpg)
telRemote sensors & PA amplifiers
REMOTE SENSORS
![Page 12: Remote Sensors And Amplifiers](https://reader033.fdocuments.us/reader033/viewer/2022042614/555be688d8b42a33078b4ec7/html5/thumbnails/12.jpg)
telRemote sensors & PA amplifiers
How to identify a sensor ?
LR 110 TB38 5
LR = Light Receiver
110 Series
TB = Threaded Brass 38 = Length
5 = 5 m cable
Red = Transmitter
Yellow = Receiver
![Page 13: Remote Sensors And Amplifiers](https://reader033.fdocuments.us/reader033/viewer/2022042614/555be688d8b42a33078b4ec7/html5/thumbnails/13.jpg)
telRemote sensors & PA amplifiers
Housing Type
Series Housing Type Dimensions
LT/LR 101 AP 25 Ø 10 x 25 mm
TP 25 M12x1 x 25 mm
TB 25 M12x1 x 25 mm
TS 25 M12x1 x 25 mm
SG 9,5 x 11,5 mm
S 22 Ø 12,7 x 22 mm
LT/LR 100/110
AP 38 Ø 10 x 38 mm
TP 38 M12x1 x 38 mm
TB 38 M12x1 x 38 mm
TS 38 M12x1 x 38 mm
TB 58 M12x1 x 58 mm
TS 58 M12x1 x 58 mm
LT/LR 120 TB 45 M18x1 x 45 mm
AP Smooth Plastic
TPThreaded Plastic
TB Threaded Brass
TS Threaded Steel
SGSpace Guard (Rectangular)
S Snap
![Page 14: Remote Sensors And Amplifiers](https://reader033.fdocuments.us/reader033/viewer/2022042614/555be688d8b42a33078b4ec7/html5/thumbnails/14.jpg)
telRemote sensors & PA amplifiers
Ga/Al/As 880 nm
LT (Transmitter)Emitting Angles50% Intensity
+/- 10 º Series 101
+/- 12 º Series 100 H
+/- 6 º Series 100
+/- 5 º Series 110
+/- 4 º Series 120
LR (Receiver)Opening Angles50% Intensity
+/- 6 º Series 101
+/- 7 º Series 100
+/- 3 º Series 110
+/- 2,5º Series 120
REMOTE SENSORS
![Page 15: Remote Sensors And Amplifiers](https://reader033.fdocuments.us/reader033/viewer/2022042614/555be688d8b42a33078b4ec7/html5/thumbnails/15.jpg)
Parallel displacement LT 101 and LR 101
-0,6
-0,4
-0,2
0
0,2
0,4
0,6
0 2 4 6 8 10
Range [m]
Dis
pla
cem
ent
[m]
telRemote sensors & PA amplifiers
![Page 16: Remote Sensors And Amplifiers](https://reader033.fdocuments.us/reader033/viewer/2022042614/555be688d8b42a33078b4ec7/html5/thumbnails/16.jpg)
Parallel displacement LT 100 and LR 100
-1,5
-1
-0,5
0
0,5
1
1,5
0 2 4 6 8 10 12 14 16 18 20
Range [m]
Dis
pla
cem
ent
[m]
telRemote sensors & PA amplifiers
![Page 17: Remote Sensors And Amplifiers](https://reader033.fdocuments.us/reader033/viewer/2022042614/555be688d8b42a33078b4ec7/html5/thumbnails/17.jpg)
Parallel displacement LT 110 and LR 110
-1,5
-1
-0,5
0
0,5
1
1,5
0 5 10 15 20 25 30 35 40 45
Range [m]
Dis
pla
ce
me
nt
[m]
telRemote sensors & PA amplifiers
![Page 18: Remote Sensors And Amplifiers](https://reader033.fdocuments.us/reader033/viewer/2022042614/555be688d8b42a33078b4ec7/html5/thumbnails/18.jpg)
Parallel displacement LT 120 and LR 120
-2,5-2
-1,5-1
-0,50
0,51
1,52
2,5
0 10 20 30 40 50 60 70 80
Range [m]
Dis
pla
cem
ent
[m]
telRemote sensors & PA amplifiers
![Page 19: Remote Sensors And Amplifiers](https://reader033.fdocuments.us/reader033/viewer/2022042614/555be688d8b42a33078b4ec7/html5/thumbnails/19.jpg)
Angular displacement LR 101
0
25
50
75
100
125
-20 -15 -10 -5 0 5 10 15 20
deg.
Se
ns
itiv
ity
(n
orm
aliz
ed
)
Angular displacement LR 100
0
25
50
75
100
125
-20 -15 -10 -5 0 5 10 15 20
deg.
Sen
siti
vity
(n
orm
aliz
ed)
Angular displacement LR 110
0
25
50
75
100
125
-20 -15 -10 -5 0 5 10 15 20
deg.
Sen
siti
vity
(n
orm
aliz
ed)
Angular displacement LR 120
0
25
50
75
100
125
-20 -15 -10 -5 0 5 10 15 20
deg.
Sen
siti
vity
(n
orm
aliz
ed)
telRemote sensors & PA amplifiers
![Page 20: Remote Sensors And Amplifiers](https://reader033.fdocuments.us/reader033/viewer/2022042614/555be688d8b42a33078b4ec7/html5/thumbnails/20.jpg)
telRemote sensors & PA amplifiers
Receivers:
Silicon NPN transistor
Immunity to Sunlight @ 20 º
LR 101 50 000 lux
LR 100 80 000 lux
LR 110/120 100 000 lux
REMOTE SENSORS
![Page 21: Remote Sensors And Amplifiers](https://reader033.fdocuments.us/reader033/viewer/2022042614/555be688d8b42a33078b4ec7/html5/thumbnails/21.jpg)
telRemote sensors & PA amplifiers
Applicable Photoelectric Amplifiers and Ranges
![Page 22: Remote Sensors And Amplifiers](https://reader033.fdocuments.us/reader033/viewer/2022042614/555be688d8b42a33078b4ec7/html5/thumbnails/22.jpg)
telRemote sensors & PA amplifiers
USEFUL ACCESSORIES
TRE Ø 10 mm A type
TREM M12 – 1 mm hole
TREGM M12 – 1 mm hole with glass front
TRGM Glass front only
TRWM 90 º shutter
TRPG 11 Tubus
![Page 23: Remote Sensors And Amplifiers](https://reader033.fdocuments.us/reader033/viewer/2022042614/555be688d8b42a33078b4ec7/html5/thumbnails/23.jpg)
- Sensing range: Through beam 0-45 mDiffuse 0-3,5 m
- Automatic mode(teach-in):Setup required (push reset/test button).Power level adjusted according the application.Optimal hysteresys and excess gain.Automatically compensation for misalignment and contamination during operation.
- Manual mode:Manual sensitivity adjustment.Test button disable the transmitter.
- Patented feature STF:Up to 3 identical systems without cross-talk
- Hysteresis: Approx. 20 %
telRemote sensors & PA amplifiers
AUTOMATIC PA TYPESPA 01
![Page 24: Remote Sensors And Amplifiers](https://reader033.fdocuments.us/reader033/viewer/2022042614/555be688d8b42a33078b4ec7/html5/thumbnails/24.jpg)
telRemote sensors & PA amplifiers
PA 01 A
![Page 25: Remote Sensors And Amplifiers](https://reader033.fdocuments.us/reader033/viewer/2022042614/555be688d8b42a33078b4ec7/html5/thumbnails/25.jpg)
telRemote sensors & PA amplifiers
PA 01 B
![Page 26: Remote Sensors And Amplifiers](https://reader033.fdocuments.us/reader033/viewer/2022042614/555be688d8b42a33078b4ec7/html5/thumbnails/26.jpg)
telRemote sensors & PA amplifiers
PA 01 C
![Page 27: Remote Sensors And Amplifiers](https://reader033.fdocuments.us/reader033/viewer/2022042614/555be688d8b42a33078b4ec7/html5/thumbnails/27.jpg)
PA AMPLIFIERS
telRemote sensors & PA amplifiers
- Sensing range: Through beam 0-5mDiffuse 0-45 cm
- Low cost:Designed for elevator and door market
- Only 12 or 24Vdc supply voltage
- Only use with LT/LR 101 serie - 1 relay output acc. to UNI8612
2 relays mounted in series
PA 09
![Page 28: Remote Sensors And Amplifiers](https://reader033.fdocuments.us/reader033/viewer/2022042614/555be688d8b42a33078b4ec7/html5/thumbnails/28.jpg)
PA AMPLIFIERSPA 10
telRemote sensors & PA amplifiers
- Sensing range: Through beam 0-60 m Diffuse 0-4 m
- PA10A:Use in conjunction with LT/LR 101 series
- PA10B:Use with LT/LR 100-110-120 series
- Relay or PNP/NPN output - Manual sensitivity adjustment- LO/DO selectable switch- Long/short range selectable switch- Hysteresis: Approx. 40 %
![Page 29: Remote Sensors And Amplifiers](https://reader033.fdocuments.us/reader033/viewer/2022042614/555be688d8b42a33078b4ec7/html5/thumbnails/29.jpg)
telRemote sensors & PA amplifiers
PA 10 A only applicable with 101 remote sensors series
PA 10 A/B
![Page 30: Remote Sensors And Amplifiers](https://reader033.fdocuments.us/reader033/viewer/2022042614/555be688d8b42a33078b4ec7/html5/thumbnails/30.jpg)
telRemote sensors & PA amplifiers
PA AMPLIFIERSPA 11 T
- Sensing range: Through beam 0-70 mDiffuse 0-5 m
- PA11:use with LT/LR 100-110-120 series
- Relay/NPN or PNP/NPN output- 0-10sec. on/off time delay- Manual sensitivity adjustment- LO/DO selectable switch- Long/short range selectable switch- Sensor test during operation (LED
indication)- Hysteresis: Approx. 45 %
![Page 31: Remote Sensors And Amplifiers](https://reader033.fdocuments.us/reader033/viewer/2022042614/555be688d8b42a33078b4ec7/html5/thumbnails/31.jpg)
telRemote sensors & PA amplifiers
PA 11 A T
![Page 32: Remote Sensors And Amplifiers](https://reader033.fdocuments.us/reader033/viewer/2022042614/555be688d8b42a33078b4ec7/html5/thumbnails/32.jpg)
telRemote sensors & PA amplifiers
PA 11 B T
![Page 33: Remote Sensors And Amplifiers](https://reader033.fdocuments.us/reader033/viewer/2022042614/555be688d8b42a33078b4ec7/html5/thumbnails/33.jpg)
telRemote sensors & PA amplifiers
- Sensing range: through beam 0-45 mdiffuse 0-3,5 m
- MPA 21:use with 2 sets LT/LR 100-110-120 series
- Multiplexing function prevent optical cross talk
- 2 individual Relay/NPN or PNP/NPN output 0-10sec. on/off time delay
- Manual sensitivity adjustment- LO/DO selectable switch- Long/short range selectable switch- Hysteresis: Approx. 35 %
MPA AMPLIFIERSMPA 21
![Page 34: Remote Sensors And Amplifiers](https://reader033.fdocuments.us/reader033/viewer/2022042614/555be688d8b42a33078b4ec7/html5/thumbnails/34.jpg)
telRemote sensors & PA amplifiers
Eliminates cross talk between 2 beams
2 relays or both PNP/NPN output
Short / long range Switch
Sensing Level indicator LED
Output LED
Available with on / off time delay
MPA 21
![Page 35: Remote Sensors And Amplifiers](https://reader033.fdocuments.us/reader033/viewer/2022042614/555be688d8b42a33078b4ec7/html5/thumbnails/35.jpg)
telRemote sensors & PA amplifiers
MPA 21 A
![Page 36: Remote Sensors And Amplifiers](https://reader033.fdocuments.us/reader033/viewer/2022042614/555be688d8b42a33078b4ec7/html5/thumbnails/36.jpg)
telRemote sensors & PA amplifiers
MPA 21 B
![Page 37: Remote Sensors And Amplifiers](https://reader033.fdocuments.us/reader033/viewer/2022042614/555be688d8b42a33078b4ec7/html5/thumbnails/37.jpg)
telRemote sensors & PA amplifiers
- Sensing range: through beam 0-35 mdiffuse 0-2 m
- MPA 41/81:use with 4/8 sets LT/LR 100 -110 - 120 series
- Multiplexing function prevent optical cross talk
- 4/8 individual Relay or PNP/NPN output w/wo 0-10sec.
- 1 relay and transistor common output- Manual sensitivity adjustment- LO/DO selectable switch- Long/short range selectable switch for all
channels- Hysteresis: Approx. 35 %
MPA AMPLIFIERSMPA 41 & MPA
81
![Page 38: Remote Sensors And Amplifiers](https://reader033.fdocuments.us/reader033/viewer/2022042614/555be688d8b42a33078b4ec7/html5/thumbnails/38.jpg)
telRemote sensors & PA amplifiers
MPA 41 A/C
![Page 39: Remote Sensors And Amplifiers](https://reader033.fdocuments.us/reader033/viewer/2022042614/555be688d8b42a33078b4ec7/html5/thumbnails/39.jpg)
telRemote sensors & PA amplifiers
MPA 41 B/D
![Page 40: Remote Sensors And Amplifiers](https://reader033.fdocuments.us/reader033/viewer/2022042614/555be688d8b42a33078b4ec7/html5/thumbnails/40.jpg)
telRemote sensors & PA amplifiers
MPA 81 A/C
![Page 41: Remote Sensors And Amplifiers](https://reader033.fdocuments.us/reader033/viewer/2022042614/555be688d8b42a33078b4ec7/html5/thumbnails/41.jpg)
telRemote sensors & PA amplifiers
MPA 81 B/D
![Page 42: Remote Sensors And Amplifiers](https://reader033.fdocuments.us/reader033/viewer/2022042614/555be688d8b42a33078b4ec7/html5/thumbnails/42.jpg)
tel