Heat Controller • 1900 Wellworth Ave. • Jackson, MI 49203 • (517)787-2100 • www.heatcontroller.com
REMOTE CONTROLLERMANUAL
DVC/DVH SeriesInverter Single ZoneDuctless Mini-Split
![Page 2: Remote Control Manual](https://reader034.fdocuments.us/reader034/viewer/2022042702/563db920550346aa9a9a4b58/html5/thumbnails/2.jpg)
2
DVC/DVH Remote Controller Heat Controller
TABLE OF CONTENTS
BatteriesandBatterySpecifications/Replacement........................................................ 3
SpecificationsandFeatures .......................................................................................... 4
Functions ....................................................................................................................... 5
RemoteControlDisplay ................................................................................................. 8
RemoteOperations ....................................................................................................... 9
![Page 3: Remote Control Manual](https://reader034.fdocuments.us/reader034/viewer/2022042702/563db920550346aa9a9a4b58/html5/thumbnails/3.jpg)
3
Heat Controller DVC/DVH Remote Controller
Remote Control Instructions
Battery Specification
1.Theremotecontrollercanbeusedtocontrolandoperatetheunit2.Theremote’ssignalcantransmitupto26ft.(8m)away.3.Anyobstructionsbetweenthesignaloftheremotecontrolandtheindoorunitcaninterfere,limitingthecapacityofthesignal.
4.Whenabuttonispressedontheremotecontrol,theindoorunitwillemita“beep”,whichindicatesthatthecommandhasbeenreceivedandtransmittedtotheindoorunit.
Tousetheremotecontrol,itisnecessarytoinstalltwo(R03/LR03x2)alkalineAAAbatteries.
Battery Replacement1.Batteriesshouldbereplacedwhenthereisnota“beep”heardfromtheindoorunitorthesignalindicatorlightdoesnotilluminatewhenbuttonsarepressedontheremoteorwhentheindoorunitdoesnotrespondtotheremotecontrolscommands.
2.Toreplacethebatteries:A.Removethecoverbypressingandslidingoff.B.Removetheoldbatteriesandinsertthenewbatteries,placingthe(+)and(-)endscorrectly.C.Reattachthecoverbyslidingitbackintoposition.
NOTE:Whenthebatteriesareremoved,theremotecontrollererasesallusersettings.Afterinsertingnewbatteries,theremotecontrollermustbereprogrammedforanyuserspecificsettings.
•Theairconditionerwillnotoperateifcurtains,doorsorothermaterialsblockthesignalfromtheremotecontroltotheunit.•Avoidspillinganyliquidintotheremote.•Donotexposetodirectsunlightorheat.•Iftheinfraredsignalreceiverontheindoorunitisexposedtodirectsunlight,theairconditionermaynotfunctionproperly.Usecurtainstopreventthesunlightfrominterferringwiththereceiver’ssignal.•Ifotherelectricalappliancessignalsreacttothesignalsentbytheremotecontrollerrelocatethese appliances.•Whenreplacingbatteries,donotuseoldbatteries•Ifyoudonotusetheremoteforaprolongedperiodoftime,removethebatteries.Otherwisetheymayleakanddamagetheremote
26 ft.(8 m)
! CAuTION
![Page 4: Remote Control Manual](https://reader034.fdocuments.us/reader034/viewer/2022042702/563db920550346aa9a9a4b58/html5/thumbnails/4.jpg)
4
DVC/DVH Remote Controller Heat Controller
Remote Controller Specifications
Performance Features
Model RG52A1/BGEFu1RatedVoltage 3.0V
SignalTransmissionDistance 26ft(8m)withfullbatteriesOperatingEnvironment 23°F~140°F(-5~60°F)
1.OperatingModes:AUTO,COOL,DRY,HEAT (heatpumpmodelsonly)andFAN.2.24hourtimer3.TemperatureRangeSelection:62°F~86°F.4.LCD(LiquidCrystalDisplay)
NOTE:Remotecontrollercanbesettodisplaydegreesin°Cor°F.Toalternatebetweenunitofmeasure,pressandholdthetempandbuttonatthesametime.Releasebuttonswhentheunitofmeasurechanges.Repeattheprocesstorevertbacktothepreviousunitofmeasure.
![Page 5: Remote Control Manual](https://reader034.fdocuments.us/reader034/viewer/2022042702/563db920550346aa9a9a4b58/html5/thumbnails/5.jpg)
5
Heat Controller DVC/DVH Remote Controller
ON/OFFPressthisbuttontopoweron,whichstartstheunit’soperation.Pushthebuttonagaintopoweroff,whichstopstheunit’soperation.
MODEEachtimethisbuttonispressed,amodeisselectedinasequenceofAUTO,COOL,DRY,HEAT*,andFANthen repeat.
*Heat mode is applicable to heat pump models only.
FANPresstoselectthefanspeedinfourintervals:
SLEEPPressthisbuttontoactivatetheSLEEPmode.Pressitagaintodeactivate.ThisfeaturecanonlybeselectedwhentheunitisinCOOL,HEAT*,orDrymode.Usethisfeatureforthemostcomfortabletemperaturecontrolwhileyousleepandyourbodytemperaturerises.*Heat mode is applicable to heat pump models only.
TuRBOActivatesordeactivatestheTurbofunction.PressthisbuttonforTurbofunction.Turbofunctionenablestheunittoreachthesettemperatureintheshortesttime.Inthecoolingmode,theunitwillblowcoldairatasuperhighfanspeed.Inheatingmode*,theunitwillblowhotairasuperhighfanspeed.*Heat mode is applicable to heat pump models only.
SELF CLEANThisfunctionhelpstokeeptheinsideoftheunitdryandpreventsmoldfromforming.Itisparticularlyusefulattheendoftheseasonwhentheunitwillnotbeinuseforalongperiodoftime.Presstheselfcleanbuttontoinitiatetheselfcleaningfunction.
Functions
1
2
3
4
5
6
*
![Page 6: Remote Control Manual](https://reader034.fdocuments.us/reader034/viewer/2022042702/563db920550346aa9a9a4b58/html5/thumbnails/6.jpg)
6
DVC/DVH Remote Controller Heat Controller
TEMP uP ( )Pushthisbuttontoincreasetheindoortemperaturesetpointin1°Fincrementsupto86°F.
TEMP DOWN ( )Pushthisbuttontodecreasetheindoortemperaturesetpointin1°Fincrementsdownto62°F.
SHORTCuT•Usedtorestorethecurrentsettingsorresumethe
previous setting.
•ThefirsttimetheunitispoweredonandtheSHORTCUTbuttonispressed,theunitwilloperateinAUTOmode,80°Fsettemp,andautofanspeed.
•Pushingthisbuttonwillautomaticallyrevertbacktotheprevioussettingsincludingoperatingmode,settemperature,fanspeedlevelandsleepfeature(ifactivated)andtransmitthesignaltotheunit.
•Whenthisbuttonispressedformorethan2seconds,thesystemwillautomaticallyrestorethecurrentoperationsettingsincludingoperatingmode,settemperatures,fanspeedandsleepfeature(ifactivated).
TIMER ONPressthebuttontoinitiatetheauto-ontimersequence.Eachpresswillincreasetheauto-ontimersettingin30minutesincrements.Whenthesettimedisplays10,eachadditiontimethebuttonispressed,itwillincreasetheauto-ontimersettingin60minuteincrements.Tocanceltheauto-ontimerprogram,simplyadjusttheauto-ontimeto0.0.
Functions
7
8
9
![Page 7: Remote Control Manual](https://reader034.fdocuments.us/reader034/viewer/2022042702/563db920550346aa9a9a4b58/html5/thumbnails/7.jpg)
7
Heat Controller DVC/DVH Remote Controller
TIMER OFFPressthebuttontoinitiatetheauto-offtimersequence.Eachpresswillincreasetheauto-timersettingin30minutesincrements.Whenthesettimedisplays10,eachadditionaltimethebuttonispresseditwillincreasetheauto-timersettingin60minuteincrements.Tocanceltheauto-timerprogram,simplyadjusttheauto-offtimerto0.0.
DIRECTPressthisbuttontodirecttheairflowbyselectingthepositionofthelouverontheunit.Eachtimethebuttonispressedthelouverwillopen/closeby6°increments. NOTE: If the louver moves in a position that could affect the cooling or heating (heat pump models only) of the air conditioner, the unit will alter the direction of the louver angle automatically.
SWINGPressthisbuttontostart/stoptheautoswingfeature,whichthelouveroscillatesupanddown. NOTE: If the louver oscillates or moves in a position that could affect heating (heat pump models only) or cooling of the air conditioner, the unit will automatically adjust the louver position.
FOLLOW ME PushthisbuttontoinitiatetheFollowMemode.Infollowmemode,thetemperaturesensorbuiltintotheremotecontrolsensestheroomtemperatureinplaceofthesensorinsidetheindoorunit.Thisallowstheremotecontroltocontrolthetemperatureoftheroomwhereitispresent.Thisfeaturehelpspreventtemperaturestratification.Wheninfollowmemode,theremotecontroldisplaywillshowtheactualroomtemperatureitsenses.
LEDDisables/Activatestheindoor\Display.Whenpushingthebutton,theindoorscreeniscleared,pressitagaintoturnonthelightofthedisplay.
Functions
10
11
12
13
14
![Page 8: Remote Control Manual](https://reader034.fdocuments.us/reader034/viewer/2022042702/563db920550346aa9a9a4b58/html5/thumbnails/8.jpg)
8
DVC/DVH Remote Controller Heat Controller
MODEDisplaysthecurrentoperationmode.Includingauto(),cool(),dry(),heat*(),fan()andbacktoauto().*Applicable to heat pump models only
TRANSMISSION INDICATORThistransmissionindicatorlightswhenremotecontrollertransmitssignalstotheindoorunit.
ON/OFFShowswhenunitison.
TIMER ONDisplayswhenTIMERONtimeisset.
TIMER OFFDisplayswhenTIMEROFFtimeisset.
SLEEPDisplayswheninSLEEPMODE.
FOLLOW MEDisplayedwhenFOLLOWMEfunctionisactivated.
TEMP./TIMER DISPLAYDisplaysthesettemperature(62°F~86°F).WhentheoperatingmodeissettoFAN,nosettemperatureisdisplayed.InTIMERmode,settheONandOFFtimesettingsare displayed.
FANDisplaystheFANspeed,AUTO(nodisplay)andthreefanspeedlevels“”(LOW)“”(MED)“”(HIGH)canbeindicated.ThefanspeedisAUTOwhentheoperatingmodeisinAUTOorDRY.
Remote Control Display
![Page 9: Remote Control Manual](https://reader034.fdocuments.us/reader034/viewer/2022042702/563db920550346aa9a9a4b58/html5/thumbnails/9.jpg)
9
Heat Controller DVC/DVH Remote Controller
AuTO OPERATION1.PresstheMODEbuttontoselectAuto.
2.PresstheUP/DOWNbuttontosetthedesiredtemperature.Thetemperaturecanbesetwithinarangeof62°F~86°Fin1°Fincrements.
• InAutomode,theunitwillautomaticallyselectCool,FanorHeat*modesbesensingthedifferencebetweentheactualambientroomtemperatureandthesettemperatureontheremotecontroller.
• IntheAutomode,youcannotchargethefanspeed.Itisbeingautomaticallycontrolled.
COOLING/HEATING/FAN OPERATIONIfAutomodeisuncomfortable,youcanmanuallyoverridethesettingbyputtingtheunitinCOOL,HEAT*,orFAN**ONLYmode.
1.PresstheMODEbuttontoselectCOOL,HEAT*(pump)orFAN**mode.
2.PressthetempUP/DOWNbuttontosetthedesiredtemperature.Thetemperaturecanbesetwithinarangeof62°F~86°Fin1°Fincrements.
3.PresstheFANbuttontoselectthefanspeedinfoursteps-Auto,Low,Med,orHigh.
NOTE * Heat mode is applicable to heat pump models only. ** In the FAN mode, the set temperature is not displayed on the remote controller and you are not able to control the room temperature either. In this case, only the fan speed can be changed.
Remote Operation
![Page 10: Remote Control Manual](https://reader034.fdocuments.us/reader034/viewer/2022042702/563db920550346aa9a9a4b58/html5/thumbnails/10.jpg)
10
DVC/DVH Remote Controller Heat Controller
DRY OPERATIONTheDRYmodewillautomaticallyselecttheamountofdehumidificationbasedonthedifferencebetweenthesettemperatureandactualroomtemperature.Thefanspeedisautomaticallysettolow.
1.PresstheMODEbuttontoselectDRYmode.
2.PresstheUP/DOWNbuttonstosetthedesiredtemperature.Thetemperaturecanbesetwithinarangeof62°F~86°Fin1°Fincrements.
NOTE• In the Dry mode, you can not change the fan speed. It
is ceing automatically controlled.• Due to the difference between the set temperature
and the actual room temperature, the unit will automatically switch between COOL and FAN only mode while in DRY mode.
ADJuSTING AIR FLOW DIRECTIONUsetheSWINGorDIRECTbuttontoadjustthedesiredairflowdirection.
1.WhentheDIRECTbuttonispushedthehorizontallouverchangesin6°degreeangleincrements.
2.WhentheSWINGbuttonispushedthelouveroscillates.
NOTE When the louver oscillates or moves in a position that could affect the cooling or heating (heat pump models only) of the air conditioner, the unit will automatically change the louver direction.
Remote Operation
1
2
![Page 11: Remote Control Manual](https://reader034.fdocuments.us/reader034/viewer/2022042702/563db920550346aa9a9a4b58/html5/thumbnails/11.jpg)
11
Heat Controller DVC/DVH Remote Controller
TIMER OPERATIONPresstheTIMERONbuttontosetthetimetheunitshouldautomaticallyturnon.PresstheTIMEROFFbuttontosetthetimetheunitshouldautomaticallyturnoff.
1.PresstheTIMERONbutton.TheremotecontrollershowTIMERON,thelastAuto-onsettimeandthe“H”iconwillbeshownontheLCDdisplay.NowitisreadytoresettheAuto-ontimetoSTARToperation.
2.PushtheTIMERONbuttonagaintosetdesiredAuto-ontime.Eachtimeyoupressthebutton,thetimeincreasesbyhalfanhourbetween0and10hoursandbyonehourbetween10and24hours.
3.AftersettingtheTIMERON,therewillbeaoneseconddelaybeforetheremotecontrollertransmitsthesignaltotheairconditioner.Then,afterapproximatelyanother2seconds,the“H”iconwilldisappearandthesettemperaturewillre-appearontheLCDdisplay.
TO SET THE AuTO-OFF TIME1.PressTIMEROFFbutton.TheremotecontrollershowTIMEROFF,thelastAuto-offsettingtimeandthe“H”iconwillbeshownontheLCDdisplayarea.NowitisreadytoresettheLCDdisplayarea.NowitisreadytoresettheAuto-offtimetostoptheoperation.
2.PushtheTIMEROFFbuttonagaintosetdesiredAuto-offtime.Eachtimeyoupressthebutton,thetimeincreasesbyhalfanhourbetween0and10hoursandbyonehourbetween10and24hours.
3.AftersettingtheTIMEROFF,therewillbeaoneseconddelaybeforetheremotecontrollertransmitsthesignaltotheairconditioner.Then,afterapproximatelyanother2seconds,thesignal“H”willdisappearandsetthetemperaturewillre-appearontheLCDdisplay.
Remote Operation
1
![Page 12: Remote Control Manual](https://reader034.fdocuments.us/reader034/viewer/2022042702/563db920550346aa9a9a4b58/html5/thumbnails/12.jpg)
12
DVC/DVH Remote Controller Heat Controller
SLEEP FuNCTIONThesleepfunctionenablestheunittoautomaticallychangethetemperatureby2°Fperhourforthefirsttwohours,thenwillremainsteadyforthenext5hours,afterthattheunitwillstopoperating.SLEEPmodecreatescomfortabletemperaturesandsavesenergy.
1.WhentheSLEEPmodeisselectedwhileinCOOLmode,thetemperatureincreasestocreatethemostuncomfortableconditionswhileyourbodytemperatureriseswhenyousleep.WhenSLEEPisselectedwhileinHEAT*mode,thetemperaturedeceasestoensureyoudon’tgettoohotwhileyourbodytemperatureriseswhenyousleep.
NOTE The SLEEP function is only selectable when the unit is in COOL, HEAT* or AUTO modes.* Heat mode is applicable to heat pump models only.
Remote Operation
1
![Page 13: Remote Control Manual](https://reader034.fdocuments.us/reader034/viewer/2022042702/563db920550346aa9a9a4b58/html5/thumbnails/13.jpg)
13
Heat Controller DVC/DVH Remote Controller
![Page 14: Remote Control Manual](https://reader034.fdocuments.us/reader034/viewer/2022042702/563db920550346aa9a9a4b58/html5/thumbnails/14.jpg)
14
DVC/DVH Remote Controller Heat Controller
![Page 15: Remote Control Manual](https://reader034.fdocuments.us/reader034/viewer/2022042702/563db920550346aa9a9a4b58/html5/thumbnails/15.jpg)
15
Heat Controller DVC/DVH Remote Controller
![Page 16: Remote Control Manual](https://reader034.fdocuments.us/reader034/viewer/2022042702/563db920550346aa9a9a4b58/html5/thumbnails/16.jpg)
16
DVC/DVH Remote Controller Heat Controller
12/2013