REMEMBRANCE USER GUIDE -...
Transcript of REMEMBRANCE USER GUIDE -...
Page 1 of 40
User Guide
Leviton Remembrance Control Stations
REMEMBRANCEDMX-512 AND ANALOG CONTROL STATIONS
USER GUIDECopyright® 2004
Leviton Manufacturing Co., Inc.
DI-00X-RMB81-00A
Page 2 of 40
User Guide
Leviton Remembrance Control Stations
Page 3 of 40
User Guide
Leviton Remembrance Control Stations
Table of ContentsSystem Overview ..................................................................................................................... 5
Remember When … ....................................................................................................................................5Welcome Back to Simplicity. ........................................................................................................................5What experience is Prerequisite? ................................................................................................................5What is needed? ..........................................................................................................................................5What is not needed? ....................................................................................................................................6
Control Station Operation ....................................................................................................... 7Play Mode ....................................................................................................................................................7DMX Snapshot Record Mode ......................................................................................................................7Record Example: ..........................................................................................................................................8DMX Channel Mode .....................................................................................................................................9
Component Functions ........................................................................................................... 10Take control PCB .......................................................................................................................................102 Channel Analog Fader PCB ....................................................................................................................10ANA-2-DMX Scene Processor PCB...........................................................................................................10
System Design Considerations ............................................................................................ 11Place HHR or DMX-512 IN jacks near DMX stations................................................................................. 11Power Supply Requirements ...................................................................................................................... 11Current Calculation Examples: ...................................................................................................................12
System Cable Requirements ................................................................................................. 13Cross Referenced Analog Compatible Cable Types: .................................................................................13Cable Derating Requirements: ...................................................................................................................13
Eliminate Ground Loops ....................................................................................................... 14What is ground? .........................................................................................................................................14Keep COM and GND separate. .................................................................................................................14Make star or daisy chain connections. .......................................................................................................14DMX daisy-chain configuration rules: .........................................................................................................14DMX bridge rules: ......................................................................................................................................14
Advanced topics..................................................................................................................... 15Use of blocking (steering) Diodes. .............................................................................................................15
Addendum .............................................................................................................................. 16Wiring Details .............................................................................................................................................16Jumper Settings .........................................................................................................................................16Preset Station DMX-512 Snapshot Record Procedure ..............................................................................17
Page 4 of 40
User Guide
Leviton Remembrance Control Stations
Sample System Configurations ............................................................................................ 18Multi-Purpose Room With A/V Control Booth .............................................................................................18Small Church (All Analog Stations) ............................................................................................................19Theater With Houselights / Rehersal Lights ...............................................................................................20Dual DMX-512 Bridge ................................................................................................................................21
Wiring Diagrams..................................................................................................................... 221 Channel Analog Station (Cat. No. 001-RMB81-001) ...............................................................................222 Channel Analog Station (Cat. No. 002-RMB81-002) ...............................................................................233 Channel Analog Station (Cat. No. 003-RMB81-003) ...............................................................................244 Channel Analog Station (Cat. No. 004-RMB81-004) ...............................................................................255 Channel Analog Station (Cat. No. 005-RMB81-005) ...............................................................................266 Channel Analog Station (Cat. No. 006-RMB81-006) ...............................................................................278 Channel Analog Station (Cat. No. 007-RMB81-008) ...............................................................................2810 Channel Analog Station (Cat. No. 008-RMB81-010) .............................................................................2912 Channel Analog Station (Cat. No. 009-RMB81-012) .............................................................................30Entry Station (Cat. No. 010-RMB81-021) ...................................................................................................31Panic Station (Cat. No. 011-RMB81-022) ..................................................................................................324 Channel DMX-512 Station (Cat. No. 017-RMB81-104) ..........................................................................336 Channel DMX-512 Station (Cat. No. 018-RMB81-106) ..........................................................................3412 Channel DMX-512 Station (Cat. No. 019-RMB81-112) .........................................................................350-10V Analog Dimmer ................................................................................................................................36
Warranty .................................................................................................................................. 38LIMITED TWO YEAR WARRANTY AND EXCLUSIONS ..............................................................38
Page 5 of 40
User Guide
Leviton Remembrance Control Stations
SYSTEM OVERVIEW
Remember When …Remember when anyone could add a house light channel or a submaster to a lighting control system by wiring aslide pot to a diode and attaching it to which ever dimmers they wanted to control? Remember when controlstations could be set up as independents, or group them with masters all without having to have a lap top, memorizeDMX-512, know Windows 95 or battle the great configuration labyrinths envisioned by dyslexic software engineers?Everything was modular and simple. There was not a central “brain” that required programming, and there was notthe hidden central processor costs and LAN limitations of most conventional architectural control systems.
Welcome Back to Simplicity.This control system uses 3 small printed circuit board and 2 standard control protocols – DMX-512 and 0-10VDC astools to create complex configurations in the simplest and least expensive way.
The three PCB’s are:
• An on/off Take Control card
• A break-away, configurable, 0-10 VDC fader board.
• A 6 Channel 0-10VDC to DMX512 Scene Processor.
What experience is Prerequisite?The only principles a designer needs to understand is:
• Take Control
• Master
• Slave
• Independent
• Snapshot DMX stream
• Pile-On (highest takes precedence)
Previous experience with 0-10VDC, diode patching and/or DMX-512 control protocols and control wiring is helpful,but not essential.
What is needed?• 0-10 VDC or DMX-512 Dimmers/Ballast’s
• A DMX-512 Control Console for developing Scenes (DMX stations only)
• A +12to +16 VDC Power Supply or Analog Stations (This power supply is not required when used in conjunctionwith a DMX Station. See page 3 for current requirements)
• 10V/5VA bell transformer for DMX Stations (The DMX station will provide 150mA of +V to drive severalAnalog Stations).
Page 6 of 40
User Guide
Leviton Remembrance Control Stations
• Standard NEMA Gang Boxes
• Imagination
What is not needed?
• A PC, DOS, Windows. Configuration files, disks or download cables. Station thumbwheel settings, A centralprocessing cabinet. Lots of patience.
Page 7 of 40
User Guide
Leviton Remembrance Control Stations
CONTROL STATION OPERATION
Play Mode
Action Result
• Press the ON/OFF (Panic) button to The LED will light, indicating the
activate the station. station is active. An Entry or Panicstation will automatically activate a scene.
• Adjust Master Fader if applicable. The Master Fader Proportionally
controls all channel levels.
• Adjust Channel Fader if applicable. Channel Faders may control one
light, a group of lights, or an entire scene.
• Press the ON/OFF (Panic) button to The lights will fade out and the
turn off the lights. LED will turn off.
DMX Snapshot Record Mode(For DMX control stations only)
Action Result
• Insure JP1 Jumper is out on The remove jumper on JP1 puts the
ANA2DMX Processor Processor in DMX Snapshot mode.
• Insure Record Lock is off. Record Lock disables any attempt to
record scenes, D19 LED onANA2DMX Processor will be Orange if ableto record. Green if unable to record.
NOTE
Record Lock can be activated any of 3 ways:
1. Jumper JP1 shorted on 2 Channel Analog PCB on station.
2. Jumper JP2 shorted on ANA2DMX processor on station.
3. REC LOCK terminal on ANA2DMX processor on station driven with external +10VDC signal.
Page 8 of 40
User Guide
Leviton Remembrance Control Stations
• Turn off all control stations. This insures only console levels will
be recorded.
• Bring up the desired scene or look on This is the scene that will be
the main console recorded.
• Go to the DMX control station. This gets the station ready to be put
Slide Master Fader all the way up to full. in record mode.Slide all the channel faders down to out.
• Push and hold the ON/OFF button when The Green LED will light.
turning the station “ON”
• Count to 5 (approximately 5 seconds) This puts the Station into record
(continue to hold the ON/OFF Button). mode. (LED on ANA2DMX PCB turns green).
• Slide the Channel Fader up to full where This snapshots the DMX-512 data
the scene is to be recorded. (continue to stream, saving the entire scene underhold the ON/OFF Button). the proportional control of the
channel fader that slid to full. The LED on theANA2DMX Processor will blink red when it isfinished recording the scene.
• Release the ON/OFF button. This exits Record Mode.
Record Example:To record scene into fader 1: (assuming REC LOCK is off)
Action
• Slide master fader to full, channel faders to out.
• Push & hold ON/OFF button when it goes from OFF to ON.
• Count out loud while continuing to hold ON/OFF button:
“One one thousand”“Two one thousand”“Three one thousand”“Four one thousand”“Five one thousand”
• Slide channel fader 1 to full.
• Release ON/OFF button.
Page 9 of 40
User Guide
Leviton Remembrance Control Stations
DMX Channel Mode(for DMX control stations only)
Action Result
• Install Jumper JP1 on ANA2DMX PCB. This puts processor in channel mode.
• Dial up the starting address on This selects the DMX start address for
rotary Switches SW1, SW2, & SW3 fader A1.
• For fader channel single pattern Faders 1-6 will respond to DMX channels
operation, remove JP4. 1-6. (assuming start address – 001).
• For fader channel dual wraparound Fader 1 controls DMX channels 1 & 7;
Pattern operation, install JP4. Fader 2 controls DMX channels 2 & 8;Fader 3 controls DMX channels 3 & 9;Fader 4 controls DMX channels 4 & 10;Fader 5 controls DMX channels 5 & 11;Fader 6 controls DMX channels 6 & 12;(assuming start address = 001)(and 6 channel operation – see JP6)
• For highest takes precedence fader The fader channel will pile-onto the
operation, remove JP5 appropriate incoming DMX channels.
• To replace the incoming DMX channel The fader channels will replace the
levels with the fader levels, install JP5 appropriate incoming DMX channel levels.
• For 4 channel operation install JP6 on This puts the processor in 4 channel on
ANA2DMX Processor. wraparound mode.
• For 6 & 12 channel operation remove This puts the processor in 6 channel on
JP6 on ANA2DMX Processor. wraparound mode.
Page 10 of 40
User Guide
Leviton Remembrance Control Stations
COMPONENT FUNCTIONS
Take control PCBThe take control PCB has a single switch for ON/OFF operation. The take control PCB requires +12 to +16 VoltsDC 25mA connected across +V and common to operate. The PCB provides a regulated +10.6 VDC source whenthe ON/OFF switch is activated (turned on) and O Volts when off.
Pressing the ON/OFF switch sends a +10VDC pulse out the T/C terminal on TB1 and down the T/C wire to resetany other stations connected to the T/C wire and TB1. The Take Control line determines and connects the stationsyou want to respond in a group. Not connecting the take control line makes the stations or groups respondindependently of each other.
When the ON led is lit, +10VDC is available on the VOUT terminal. The VOUT signal can be used to activate asingle analog channel, or when used with prep cable PRP-31316-02, it can be used to activate several channels atonce. The VOUT signal’s most common application is to implement Panic or Entry Stations. See the Wiring Diagramsfor Entry or Panic stations for more details.
2 Channel Analog Fader PCBThe Fader PCB is a breakable PCB array that can be easily be configured for 1-12 channels with or without amaster fader. The input/output bussed connector scheme of J1/P1 passes DC power, analog 0-10V levels, andtake control across the control station to the terminal block on the take control card, or to a header for the ANA-2-DMX PCB. All 0-10V analog channels are buffered by an op-amp and diode blocked before leaving the PCB.
ANA-2-DMX Scene Processor PCBThe ANA-2-DMX PCB utilizes six 0-10 VDC analog control inputs to proportionally drive 6 DMX submaster scenesthat pile-onto each other and to the incoming DMX signal whether active or inactive. To record a scene, first bringup the desired look on the console running to the DMX IN terminal. Next, slide the master to full and the channelsto off. Push and hold the ON/OFF button to ON for about 5 seconds on the station, putting the station in recordmode. Finally, slide the fader up to full for the channel you wish to record the scene into. As long as the recordlockout is not enabled, the scene will be saved onto that channel, and will proportionally fade relative to the slidepot. For user convenience, the record lockout function which disables re-recording scenes is available on the DMXterminal Block, as a jumper on the ANA-2-DMX PCB itself, and also as a jumper on the 2 channel fader PCB.Record lock is perfect for setting up house light channels or looks, and then disabling the record function forpatrons. A DMX bypass relay is provided in the event of a power supply failure.
Page 11 of 40
User Guide
Leviton Remembrance Control Stations
SYSTEM DESIGN CONSIDERATIONS
Place HHR or DMX-512 IN jacks near DMX stationsPlace a Hand Held Remote Jack from the control console or a DMX-512 IN Jack where the console could beplugged in near any station that will be used to snapshot scenes on a frequent basis. This way scenes can beactivated from the console in the same place they are to be recorded.
Power Supply Requirements
DMX Station Current Supply:
(+V/COM power supply source for a single station connected to a single 10V/5VA transformer)
Station Type Supply Current Catalog No. # of Gang
4 Channel DMX Station 150mA 017-RMB81-104 4
6 Channel DMX Station 150mA 018-RMB81-106 5
12 Channel DMX Station 100mA 019-RMB81-112 8
12 Channel DMX station connected to qty 2-10V/5VA transformers. (transformers connected to separateAC1/AC2 inputs) 250ma.
NOTE
The +V/COM current through a DMX station should not exceed 750mA.
Analog Station Current Demands:
+V power supply requirements for a single station (+12 to +16 VDC)
Station Type ON OFF Catalog Bo. # of Gangs
Entry Station 25 mA 5mA 010-RMB81-021 1Panic Station 25 mA 5mA 011-RMB81-022 11 Channel Analog 30 mA 5mA 001-RMB81-001 22 Channel Analog 30 mA 5mA 002-RMB81-002 23 Channel Analog 35 mA 5mA 003-RMB81-003 44 Channel Analog 40 mA 5mA 004-RMB81-004 45 Channel Analog 45 mA 5mA 005-RMB81-005 56 Channel Analog 50 mA 5mA 006-RMB81-006 58 Channel Analog 60 mA 5mA 007-RMB81-008 610 Channel Analog 70 mA 5mA 008-RMB81-010 712 Channel Analog 80 mA 5mA 009-RMB81-012 8
Page 12 of 40
User Guide
Leviton Remembrance Control Stations
Current Calculation Examples:
3 Grouped Stations
Current demand calculation for qty 3, 6 channel stations connected in a group: T/C connected between stations,therefore only one station can be on at a time.
+V Amps = 50mA (station 1) + 5mA (station 2) + 5mA (Station 3) = 60mA
3 Independent Stations
Current demand calculation for qty 3, 6 channel stations connected independently; T/C not used. All 3 could be onat the same time.
+V Amps = 50mA (station 1) + 50mA (station 2) + 50mA (Station 3) = 150mA
Page 13 of 40
User Guide
Leviton Remembrance Control Stations
SYSTEM CABLE REQUIREMENTS
All DMX-512 lines ............................................. Belden # 9829 cable
All Analog lines ................................................. Alpha # 1898/x C cable1000 feet MAX!! Where x = the # of conductors
All AC1 and AC2 lines ....................................... 18 gauge 600V wire
Cross Referenced Analog Compatible Cable Types:Belden 8489 (4 conductor)
Belden 8467 (7 conductor)
Belden 8466 (12 conductor)
Belden 8619 (19 conductor) (color code does not match)
National # NQ-418J (4 conductor)
National # NQ-718J (7 conductor)
National # NQ-1018J (10 conductor)
National # NQ-1918J (19 conductor) (color code does not match)
Cable Derating Requirements:Smaller gauges of multi conductor Alpha wire can be used for short runs with a minimum number of stations iffollowing list of the criteria is met:
Alpha #1896 (20 gauge conductors) can be used if:
1. The total analog cable length for the system does not exceed 300 Feet. AND
2. The maximum number of stations is 6.
Alpha #1774 thru #1180 (22 gauge conductors) can be used if:
1. The total analog cable length for the system does not exceed 100 Feet. AND
2. The maximum number of stations is 4. AND
3. The maximum number of channels is 6.
Page 14 of 40
User Guide
Leviton Remembrance Control Stations
ELIMINATE GROUND LOOPS
What is ground?This control system, like most other control systems requires a common reference for the electronics to functionproperly. This reference is typically denoted as Common or Ground. Control voltages are measured with respect tothis ground reference, just like the height of a person would normally be measured with respect to the ground theyare standing on. Without a proper common reference, the electronics can not make accurate voltage measurements,and therefore will not function correctly.
Keep COM and GND separate.The ANA 2DMX PCB has 2 different control references. COM (Analog Common) and GND (Digital Ground). Thetwo are nearly the same, except COM is the reference for all the analog control levels and GND (digital ground) isthe reference for the digital electronics and the incoming power supply. COM and GND should never be connectedtogether with external wiring. Never place This control systems control lines in conduit with other wires, or flickeringproblems could occur.
Make star or daisy chain connections.In this electronics system, it is important for all the COM signals to be connected in a start or daisy-chain configuration,as opposed to a ring o loop configuration. The reason is that a ring or loop configuration usually acts like a bigantenna which is excited and aggravated by adjacent power lines. Apply the following rules:
DMX daisy-chain configuration rules:(multiple DMX Stations connected in serial along one DMX-512 line)
1. Do not connect COM between DMX stations.
2. Use a separate power supply for each DMX station.
3. Daisy-chain the DMX-512 signal as normal, connecting the shield drain to DGND.
DMX bridge rules:(2 or more DMX Stations tied together with COM, each processing its’ own DMX-512 line)
1. Tie stations together using COM
2. Use a separate 10V/5VA transformer for each DMX Station
3. Connect the shield drain wire to DGND on the DMX-1 station.
4. Do not connect the shield drain wire to DGND on additional DMX stations (DMX-2, 3, 4 _). Leave the DGNDTerminals or DMX IN/OUT empty. The DMX shield can be passed through the station location, but it shouldnot touch or connect to anything in the box.
Page 15 of 40
User Guide
Leviton Remembrance Control Stations
ADVANCED TOPICS
Use of blocking (steering) Diodes.
What is a Diode?
A diode is a one-way valve. It allows current to flow in a forward direction, but not in a reverse direction. The inputis the anode, or un-banded end of the part; and the output is the cathode, or banded end of the part. When the input(anode) is at a voltage potential higher than the output (cathode), current will pass from the input to the output untilit fills up the output connection to nearly the same voltage level as available on the input connection. When theoutput voltage rises higher than the input voltage, the part shuts off
Analog Channel Grouping
Use 1N4148 or 1N914 diodes to select multiple Analog Channels to be controlled by a single fader, Entry, or Panicstation. This is done by connecting the banded end (cathode) of the diodes to each of the Analog Channels to becontrolled. Tie the un-banded ends together, and to the single VOUT or A (1-6) single fader control line that is tocontrol the channels. The diodes will keep the channels to be controlled separate except when the source channelis active. The 1N4148 or 1N914 is considered a signal diode. It is excellent for quick linear response in low-currentapplications, however it has a tendency to fail in high current applications.
Master/Slave Take Control
Un 1N4004 diodes to create Master/Slave take Control relationships between control stations. This is implementedby attaching the un-banded end (anode) to the master station, and the banded end (cathode) to the slave station(s).The master station will now be able to take control away from the slave station(s), but the slave station(s) will not beable to take control away from the master station. The master station will act as an independent from the slave(s)stations point of view. The slave station will also be unable to record presets if the master station is a DMX station,as the record operation is a function of the take control circuit. The 1N4004 is considered a rectifier diode, and isexcellent for high-current applications, like the take control circuitry, but it would perform poorly as a signal diode,because it requires significant current to operate properly.
Page 16 of 40
User Guide
Leviton Remembrance Control Stations
ADDENDUM
Concerning New REMEMBRANCE Preset Stations:
Wiring Details
8 Preset Station: Refer to 8 Channel Analog Station Wiring Diagram and Colortran(8-1028, 8-1148, 8-1188) Colortran Production Drawings for connection details of this Preset
Station in your specific system.
4 Preset Station: Refer to Colortan Production Drawings for connection(8-1024, 8-1144) details of this Preset Station in your specific system. Note
the following control wire mapping.
Station Terminal A2 = Preset #1 (usually System A1)Station Terminal A3 = Preset #2 (usually System A2)Station Terminal A6 = Preset #3 (usually System A3)Station Terminal A7 = Preset #4 (usually System A4)Station Terminal +V = +V for systemStation Terminal COM = COM for systemStation Terminal T/C = T/C as applicable in system design.
NOTE
Connect Station Terminal A1 to Station Terminal A2 on 4 presetstations to activate Preset 1 on power up.
Jumper Settings
JP3 IN: Enable Snapshot Record feature from this Station DMX-512 SceneSnapshot Record may be enabled if T/C is connected to recordingprocessor (either i series e control module, or REMEMBRANCE ANA2DMXprocessor). The station will also activate presets, and take control awayfrom other stations connected to its’ T/C line. Refer to Colortan ProductionDrawings for connection details, and refer to the snapshot record procedurebelow for operational details. The “OFF” LED will stay red while the “OFF”switch is pressed.
JP3 OUT: Disable Snapshot Record from this station. The station will only activatepresets, and take control away from other stations connected to its’ T/C.Line. The OFF LED will pulse red when the “OFF” switch is pressed.
JP5 IN: Activate Preset 1 on power up. Preset 1 will automatically turn on whenpower is applied to the station.
JP5OUT: Activate OFF on power up. All preset will be off when power is applied tothe control station.
Page 17 of 40
User Guide
Leviton Remembrance Control Stations
Preset Station DMX-512 Snapshot Record Procedure1. JP3 must be installed on this station.
2. Activate DMX-512 scene from control console or DMX-512 portion of control station. On i series e racks, ori series e Quad racks, a relative fade time for the preset may be assigned by setting DMX channels 511 and512 to the same control level as follows:
Full = 90 seconds90% = 9 seconds80% = 8 seconds70% = 7 seconds60% = 6 seconds50% = 5 seconds40% = 4 seconds30% = 3 seconds20% = 2 seconds10% = 1 seconds0% = Instantaneous
3. Turn off all other control sources, so only DMX-512 generated scene is active.
4. Press and hold the “OFF” Button. The “OFF” LED will turn and stay red.
5. Continue pressing the OFF switch for at least 5 seconds. If the preset station is connected to an i series erack, the lights will dim when the snapshot mode has been enabled. If the station is connected to an ANA2DMXprocessor, wait an extra second or two to insure that the processor is in snapshot mode.
6. While holding the OFF switch, press the preset switch where you would like the DMX512 scene stored.
7. Continue to hold the OFF button for another second or until the lights return to their normal levels.
8. Release the OFF button.
Page 18 of 40
User Guide
Leviton Remembrance Control Stations
SAMPLE SYSTEM CONFIGURATIONS
MA
ST
ER
ON
/ O
FF
Remembrance
MA
ST
ER
ON
/ O
FF
Remembrance
CO
M+
VT
/CV
OU
TA
1A
2A
3
COM
+V
T/C
VOUT
A1
A2
A3
A4
A5
A6
A7
A8
A9
A10
A11
A12
10V
AC
X10
VA
CY
RE
C L
OC
KD
MX
OU
T+
DM
X O
UT-
DG
ND
OU
TD
MX
IN+
DM
X IN
-D
GN
D IN
A
MA
ST
ER
ON
/ O
FF
Remembrance
CO
M+
VT
/CV
OU
TA
1A
2A
3
B
RO
OM
13
CH
AN
NE
L A
NA
LOG
CA
T. N
O. 0
03-R
MB
81-3
CO
MB
INE
RO
OM
S
MA
ST
ER
ON
/ O
FF
Remembrance
CO
M+
VT
/CV
OU
TA
1A
2A
3
A
MA
ST
ER
ON
/ O
FF
Remembrance
CO
M+
VT
/CV
OU
TA
1A
2A
3
B
RO
OM
2 C
HA
NN
EL
AN
ALO
GC
AT.
NO
. 003
-RM
B81
-3
10V
/5V
A F
XM
RB
Y O
TH
ER
SA
/V B
OO
TH
MA
ST
ER
STA
TIO
N12
CH
AN
NE
L D
MX
STA
TIO
N C
AT.
NO
. 019
-RM
B81
-112
SLA
VE
STA
TIO
NS
LOC
KO
UT
CO
MB
INE
RO
OM
S
MA
ST
ER
ON
/ O
FF
Remembrance
CO
M+
VT
/CV
OU
TA
1A
2A
3
A
MA
ST
ER
ON
/ O
FF
Remembrance
CO
M+
VT
/CV
OU
TA
1A
2A
3
B
RO
OM
33
CH
AN
NE
L A
NA
LOG
CA
T. N
O. 0
03-R
MB
81-3
CO
MB
INE
RO
OM
S
MA
ST
ER
ON
/ O
FF
Remembrance
CO
M+
VT
/CV
OU
TA
1A
2A
3
A
MA
ST
ER
ON
/ O
FF
Remembrance
CO
M+
VT
/CV
OU
TA
1A
2A
3
B
RO
OM
43
CH
AN
NE
L A
NA
LOG
CA
T. N
O. 0
03-R
MB
81-3
CO
MB
INE
RO
OM
S
120V
AC
CO
NTR
OL
CO
NS
OLE
DM
X-5
12 B
ELD
EN
982
9 B
Y O
TH
ER
S
DM
X-5
12 B
ELD
EN
982
9 B
Y O
TH
ER
S
DIM
ME
R
RA
CK
RO
OM
1R
OO
M 2
RO
OM
4R
OO
M 3
A/V
BO
OT
H
AIR
WA
LLS
A
A
A
A B
B
B
B
NO
TE
Use
Alp
ha #
1898
wire
bet
wee
nal
l con
trol
sta
tions
.
Mu
lti-
Pu
rpo
se R
oo
m W
ith
A/V
Co
ntr
ol B
oo
th
Page 19 of 40
User Guide
Leviton Remembrance Control Stations
CO
M+
VT
/CV
OU
TA
1A
2COM
+V
T/C
VOUT
A1
A2
A3
A4
A5
A6
A7
A8
CO
M+
VT
/CV
OU
TA
1A
2
CO
M+
VT
/CV
OU
T
HOUSE DOWNLIGHTSVESTIBULE
NS
I CA
T. N
O. N
2408
VE
ST
IBU
LEE
NT
RY
STA
TIO
NC
AT.
NO
. 010
-RM
B81
-21
HO
US
E R
IGH
TT
WO
CH
AN
NE
LA
NA
LOG
STA
TIO
NC
AT.
NO
. 002
-RM
B81
-2
HO
US
E L
EF
TT
WO
CH
AN
NE
LA
NA
LOG
STA
TIO
NC
AT.
NO
. 002
-RM
B81
-2
PODIUMSANCTUARY WASHSOLOISTCHOIRBABTISMALHOUSE CHANDELIERHOUSE DOWNLIGHTSVESTIBULE
SA
NC
TU
AR
Y (
MA
ST
ER
STA
TIO
N)
8 C
HA
NN
EL
AN
ALO
G S
TAT
ION
CA
T. N
O. 0
07-R
MB
81-8
MA
ST
ER
ON
/ O
FF
Remembrance
ON
/ O
FF
Remembrance
ON
/ O
FF
Remembrance
ON
/ O
FF
Remembrance
DM
X -
DM
X -
DM
X +
DM
X +
MC
PX
MC
PX
+ 1
5V+
15V
RE
M +
RE
M +
RE
M -
RE
M-
1 2 3 4 CO
MC
OM
1 2 3 4 CO
MC
OM
NO
TE
Use
Alp
ha #
1898
wire
bet
wee
nal
l con
trol
sta
tions
.
Sm
all C
hu
rch
(A
ll A
nal
og
Sta
tio
ns)
Page 20 of 40
User Guide
Leviton Remembrance Control Stations
MA
ST
ER
ON
/ O
FF
Remembrance
MA
ST
ER
ON
/ O
FF
Remembrance
CO
M+
VT
/CV
OU
TA
1A
2A
3
COM
+V
T/C
VOUT
A1
A2
A3
A4
A5
A6
A7
A8
A9
A10
A11
A12
COM+VT/CVOUT
10V
AC
X10
VA
CY
RE
C L
OC
KD
MX
OU
T+
DM
X O
UT-
DG
ND
OU
TD
MX
IN+
DM
X IN
-D
GN
D IN
A
MA
ST
ER
ON
/ O
FF
Remembrance
CO
M+
VT
/CV
OU
TA
1A
2A
3
B
MA
ST
ER
ON
/ O
FF
Remembrance
CO
M+
VT
/CV
OU
TA
1A
2A
3
3 C
HA
NN
EL
AN
ALO
G S
TAT
ION
SC
AT.
NO
. 003
-RM
B81
-3
HO
US
ELI
GH
TS
TAT
ION
S
3 E
NT
RY
STA
TIO
NS
CA
T. N
O. 0
10-R
MB
81-2
1
EN
TR
Y (
CLE
AN
ING
)S
TAT
ION
S
10V
/5V
A F
XM
RB
Y O
TH
ER
S
CO
NT
RO
L B
OO
TH
12 C
HA
NN
EL
DM
X S
TAT
ION
CA
T. N
O. 0
19-R
MB
81-1
12
RE
HE
RS
AL
LIG
HT
SH
OU
SE
LIG
HT
S
ENTRY
EN
TR
Y S
TAT
ION
CA
T. N
O. 0
10-R
MB
81-2
1
HO
US
ELI
GH
T /
EN
TR
Y S
TAT
ION
SLO
CK
OU
T
HO
US
ELI
GH
T /
EN
TR
Y S
TAT
ION
SLO
CK
OU
T
120V
AC
CO
NTR
OL
CO
NS
OLE
DM
X-5
12 B
ELD
EN
982
9 B
Y O
TH
ER
S
DM
X-5
12 B
ELD
EN
982
9 B
Y O
TH
ER
S
DIM
ME
R
RA
CK
ON
/ O
FF
Remembrance
MA
ST
ER
ON
/ O
FF
Remembrance
COM
+V
T/C
VOUT
A1
A2
A3
A4
A5
A6
A7
A8
A9
A10
A11
A12
COM+VT/CVOUT
STA
GE
MA
NA
GE
RS
PA
NE
L12
CH
AN
NE
L A
NA
LOG
STA
TIO
NC
AT.
NO
. 019
-RM
B81
-112
EN
TR
Y S
TAT
ION
CA
T. N
O. 0
10-R
MB
81-2
1
ON
/ O
FF
Remembrance
CO
M+
VT
/CV
OU
T
B
ON
/ O
FF
Remembrance
CO
M+
VT
/CV
OU
T
B
ON
/ O
FF
Remembrance
CO
M+
VT
/CV
OU
T
B
ON
/ O
FF
Remembrance
Th
eate
r Wit
h H
ou
selig
hts
/ R
ehea
rsal
Lig
hts
NO
TE
Use
Alp
ha #
1898
wire
bet
wee
nal
l con
trol
sta
tions
.
Page 21 of 40
User Guide
Leviton Remembrance Control Stations
Du
al D
MX
-512
Bri
dg
e
MA
ST
ER
ON
/ O
FF
Remembrance
COM
+V
T/C
VOUT
A1
A2
A3
A4
A5
A6
A7
A8
A9
A10
A11
A12
AC
1A
C2
RE
C L
OC
KD
MX
OU
T+
DM
X O
UT-
DG
ND
OU
TD
MX
IN+
DM
X IN
-D
GN
D IN
10V
/5V
A F
XM
RB
Y O
TH
ER
S
CO
NT
RO
L B
OO
TH
12 C
HA
NN
EL
DM
X S
TAT
ION
CA
T. N
O. 0
19-R
MB
81-1
12
MA
ST
ER
ON
/ O
FF
Remembrance
COM
+V
T/C
VOUT
A1
A2
A3
A4
A5
A6
A7
A8
A9
A10
A11
A12
HE
AD
US
HE
RS
PA
NE
L12
CH
AN
NE
L A
NA
LOG
STA
TIO
NC
AT.
NO
. 009
-RM
B81
-12
120V
AC
CO
NTR
OL
CO
NS
OLE
DM
X2
DM
X1
BE
LDE
N #
9829
BY
OT
HE
RS
DR
AIN
WIR
E P
AS
SE
ST
RH
RO
UG
H S
TAT
ION
LOC
AT
ION
, BU
T IS
INS
ULA
TE
D F
RO
MS
TAT
ION
AN
DE
NC
LOS
UR
E
BE
LDE
N #
9829
BY
OT
HE
RS
ALP
HA
#18
98/1
5CB
Y O
TH
ER
S
MA
ST
ER
ON
/ O
FF
Remembrance
COM
+V
T/C
VOUT
A1
A2
A3
A4
A5
A6
A7
A8
A9
A10
A11
A12
AC
1A
C2
RE
C L
OC
KD
MX
OU
T+
DM
X O
UT-
DG
ND
OU
TD
MX
IN+
DM
X IN
-D
GN
D IN
10V
/5V
A F
XM
RB
Y O
TH
ER
S
STA
GE
MA
NA
GE
RS
PA
NE
L12
CH
AN
NE
L D
MX
STA
TIO
NC
AT.
NO
. 019
-RM
B81
-112
MA
ST
ER
ON
/ O
FF
Remembrance
COM
+V
T/C
VOUT
A1
A2
A3
A4
A5
A6
A7
A8
A9
A10
A11
A12
PO
DIU
M /
DE
SIG
NE
RS
RE
MO
TE
12 C
HA
NN
EL
AN
ALO
G S
TAT
ION
CA
T. N
O. 0
09-R
MB
81-1
2
120V
AC
DIM
ME
R
RA
CK
S
NO
TE
Use
Alp
ha #
1898
wire
bet
wee
nal
l con
trol
sta
tions
.
Page 22 of 40
User Guide
Leviton Remembrance Control Stations
WIRING DIAGRAMS
1 Channel Analog Station (Cat. No. 001-RMB81-001)
ON / OFF
Remembrance
FRONT VIEW
REAR VIEW
A6A5A4A3A2A1VOUTT/C+VCOM
10987654321
ORANGENO CONNECTWHITEREDBLACK
GREEN-VOUT FROMENTRY STATION /PANIC STATION
ALPHA1898/5C
BY OTHERS
TB1
ANALOGCONTROLHARNESSTO OTHERSTATIONS
OR TO0-10V DIMMERS
SIDE VIEW
EL
EC
TR
ON
ICS
TE
RM
INA
L B
LO
CK BEST
K/OACCESS
BESTK/O
ACCESS
FAIRK/O
ACCESS
NO K/OACCESS
FAIRK/OACCESS
FAIRK/OACCESS
FAIRK/O
ACCESS
2 GANG3-1/2" DEEPBACK BOXBY OTHERS
5/16"
3 1/2"
1"
Page 23 of 40
User Guide
Leviton Remembrance Control Stations
2 Channel Analog Station (Cat. No. 002-RMB81-002)
ON / OFF
Remembrance
FRONT VIEW
REAR VIEW
A6A5A4A3A2A1VOUTT/C+VCOM
10987654321
BLUEORANGENO CONNECTWHITEREDBLACK
GREEN-VOUT FROMENTRY STATION /PANIC STATION
ALPHA1898/6C
BY OTHERS
TB1
ANALOGCONTROLHARNESSTO OTHERSTATIONS
OR TO0-10V DIMMERS
SIDE VIEW
EL
EC
TR
ON
ICS
TE
RM
INA
L B
LO
CK BEST
K/OACCESS
BESTK/O
ACCESS
FAIRK/O
ACCESS
NO K/OACCESS
FAIRK/OACCESS
FAIRK/OACCESS
FAIRK/O
ACCESS
2 GANG3-1/2" DEEPBACK BOXBY OTHERS
5/16"
3 1/2"
1"
Page 24 of 40
User Guide
Leviton Remembrance Control Stations
3 Channel Analog Station (Cat. No. 003-RMB81-003)
MASTER
ON / OFF
Remembrance
FRONT VIEW
REAR VIEW
A6A5A4A3A2A1VOUTT/C+VCOM
10987654321
BROWNBLUEORANGENO CONNECTWHITEREDBLACK
GREEN-VOUT FROMENTRY STATION /PANIC STATION
ALPHA1898/7C
BY OTHERS
TB1
ANALOGCONTROLHARNESSTO OTHERSTATIONS
OR TO0-10V DIMMERS
SIDE VIEW
EL
EC
TR
ON
ICS
TE
RM
INA
L B
LO
CK BEST
K/OACCESS
BESTK/O
ACCESS
FAIRK/O
ACCESS
NO K/OACCESS
FAIRK/OACCESS
FAIRK/OACCESS
FAIRK/O
ACCESS
4 GANG3-1/2" DEEPBACK BOXBY OTHERS
5/16"
3 1/2"
1"
Page 25 of 40
User Guide
Leviton Remembrance Control Stations
4 Channel Analog Station (Cat. No. 004-RMB81-004)
MASTER
ON / OFF
Remembrance
FRONT VIEW
REAR VIEW
A6A5A4A3A2A1VOUTT/C+VCOM
10987654321
YELLOWBROWNBLUEORANGENO CONNECTWHITEREDBLACK
GREEN-VOUT FROMENTRY STATION /PANIC STATION
ALPHA1898/8C
BY OTHERS
TB1
ANALOGCONTROLHARNESSTO OTHERSTATIONS
OR TO0-10V DIMMERS
SIDE VIEW
EL
EC
TR
ON
ICS
TE
RM
INA
L B
LO
CK BEST
K/OACCESS
BESTK/O
ACCESS
FAIRK/O
ACCESS
NO K/OACCESS
FAIRK/OACCESS
FAIRK/OACCESS
FAIRK/O
ACCESS
4 GANG3-1/2" DEEPBACK BOXBY OTHERS
5/16"
3 1/2"
1"
Page 26 of 40
User Guide
Leviton Remembrance Control Stations
5 Channel Analog Station (Cat. No. 005-RMB81-005)
MASTER
ON / OFF
Remembrance
FRONT VIEW
REAR VIEW
A6A5A4A3A2A1VOUTT/C+VCOM
10987654321
GRAYVIOLETYELLOWBROWNBLUEORANGENO CONNECTWHITEREDBLACK
GREEN-VOUT FROMENTRY STATION /PANIC STATION
ALPHA1898/10C
BY OTHERS
TB1
ANALOGCONTROLHARNESSTO OTHERSTATIONS
OR TO0-10V DIMMERS
SIDE VIEW
EL
EC
TR
ON
ICS
TE
RM
INA
L B
LO
CK BEST
K/OACCESS
BESTK/O
ACCESS
FAIRK/O
ACCESS
NO K/OACCESS
FAIRK/OACCESS
FAIRK/OACCESS
FAIRK/O
ACCESS
5 GANG3-1/2" DEEPBACK BOXBY OTHERS
5/16"
3 1/2"
1"
Page 27 of 40
User Guide
Leviton Remembrance Control Stations
6 Channel Analog Station (Cat. No. 006-RMB81-006)
MASTER
ON / OFF
Remembrance
FRONT VIEW
REAR VIEW
A6A5A4A3A2A1VOUTT/C+VCOM
10987654321
GRAYVIOLETYELLOWBROWNBLUEORANGENO CONNECTWHITEREDBLACK
GREEN-VOUT FROMENTRY STATION /PANIC STATION
ALPHA1898/10C
BY OTHERS
TB1
ANALOGCONTROLHARNESSTO OTHERSTATIONS
OR TO0-10V DIMMERS
SIDE VIEW
EL
EC
TR
ON
ICS
TE
RM
INA
L B
LO
CK BEST
K/OACCESS
BESTK/O
ACCESS
FAIRK/O
ACCESS
NO K/OACCESS
FAIRK/OACCESS
FAIRK/OACCESS
FAIRK/O
ACCESS
5 GANG3-1/2" DEEPBACK BOXBY OTHERS
5/16"
3 1/2"
1"
Page 28 of 40
User Guide
Leviton Remembrance Control Stations
8 C
han
nel
An
alo
g S
tati
on
(Cat
. No
. 007
-RM
B81
-008
)
MA
ST
ER
ON
/ O
FF
Remembrance
FR
ON
T V
IEW
RE
AR
VIE
W
A12
A2
A10
A9
A8
A7
A6
A5
A4
A3
A2
A1
VOUT
T/C
+V COM
10 9 8 7 6 5 4 3 2 1
GR
AY
VIO
LE
TY
EL
LO
WB
RO
WN
BL
UE
OR
AN
GE
NO
CO
NN
EC
TW
HIT
ER
ED
BL
AC
K
GR
EE
N-V
OU
T F
RO
ME
NT
RY
STA
TIO
N /
PAN
IC S
TAT
ION
AL
PH
A18
98/1
2CB
Y O
TH
ER
S
TAN
PIN
K
6 5 4 3 2 1
TB
1
TB
2
AN
AL
OG
CO
NT
RO
LH
AR
NE
SS
TO O
TH
ER
STA
TIO
NS
OR
TO
0-10
V D
IMM
ER
S
SID
E V
IEW
ELECTRONICS
TERMINAL BLOCK
BE
ST
K/O
AC
CE
SS
BE
ST
K/O
AC
CE
SS
FAIR
K/O
AC
CE
SS
NO
K/O
AC
CE
SS
FAIR
K/O
AC
CE
SS
FAIR
K/O
AC
CE
SS
FAIR
K/O
AC
CE
SS
6 G
AN
G3-
1/2"
DE
EP
BA
CK
BO
XB
Y O
TH
ER
S
5/16
"
3 1/
2"
1"
Page 29 of 40
User Guide
Leviton Remembrance Control Stations
10 C
han
nel
An
alo
g S
tati
on
(Cat
. No
. 008
-RM
B81
-010
)
MA
ST
ER
ON
/ O
FF
Remembrance
FR
ON
T V
IEW
RE
AR
VIE
W
A12
A2
A10
A9
A8
A7
A6
A5
A4
A3
A2
A1
VOUT
T/C
+V COM
10 9 8 7 6 5 4 3 2 1
GR
AY
VIO
LE
TY
EL
LO
WB
RO
WN
BL
UE
OR
AN
GE
NO
CO
NN
EC
TW
HIT
ER
ED
BL
AC
K
GR
EE
N-V
OU
T F
RO
ME
NT
RY
STA
TIO
N /
PAN
IC S
TAT
ION
AL
PH
A18
98/1
4CB
Y O
TH
ER
S
RE
D/Y
EL
RE
D/G
RN
TAN
PIN
K
6 5 4 3 2 1
TB
1
TB
2
AN
AL
OG
CO
NT
RO
LH
AR
NE
SS
TO O
TH
ER
STA
TIO
NS
OR
TO
0-10
V D
IMM
ER
S
SID
E V
IEW
ELECTRONICS
TERMINAL BLOCK
BE
ST
K/O
AC
CE
SS
BE
ST
K/O
AC
CE
SS
FAIR
K/O
AC
CE
SS
NO
K/O
AC
CE
SS
FAIR
K/O
AC
CE
SS
FAIR
K/O
AC
CE
SS
FAIR
K/O
AC
CE
SS
7 G
AN
G3-
1/2"
DE
EP
BA
CK
BO
XB
Y O
TH
ER
S
5/16
"
3 1/
2"
1"
Page 30 of 40
User Guide
Leviton Remembrance Control Stations
12 C
han
nel
An
alo
g S
tati
on
(Cat
. No
. 009
-RM
B81
-012
)
MA
ST
ER
ON
/ O
FF
Remembrance
FR
ON
T V
IEW
RE
AR
VIE
W
A12
A2
A10
A9
A8
A7
A6
A5
A4
A3
A2
A1
VOUT
T/C
+V COM
10 9 8 7 6 5 4 3 2 1
GR
AY
VIO
LE
TY
EL
LO
WB
RO
WN
BL
UE
OR
AN
GE
NO
CO
NN
EC
TW
HIT
ER
ED
BL
AC
K
GR
EE
N-V
OU
T F
RO
ME
NT
RY
STA
TIO
N /
PAN
IC S
TAT
ION
AL
PH
A18
98/1
6CB
Y O
TH
ER
S
WH
T/B
LK
RE
D/B
LK
RE
D/Y
EL
RE
D/G
RN
TAN
PIN
K
6 5 4 3 2 1
TB
1
TB
2
AN
AL
OG
CO
NT
RO
LH
AR
NE
SS
TO O
TH
ER
STA
TIO
NS
OR
TO
0-10
V D
IMM
ER
S
SID
E V
IEW
ELECTRONICS
TERMINAL BLOCK
BE
ST
K/O
AC
CE
SS
BE
ST
K/O
AC
CE
SS
FAIR
K/O
AC
CE
SS
NO
K/O
AC
CE
SS
FAIR
K/O
AC
CE
SS
FAIR
K/O
AC
CE
SS
FAIR
K/O
AC
CE
SS
8 G
AN
G3-
1/2"
DE
EP
BA
CK
BO
XB
Y O
TH
ER
S
5/16
"
3 1/
2"
1"
Page 31 of 40
User Guide
Leviton Remembrance Control Stations
Entry Station (Cat. No. 010-RMB81-021)
ON / OFF
Remembrance
FRONT VIEW
REAR VIEW
VOUTT/C+VCOM
4321
GREENWHITEREDBLACK
ALPHA1898/4C
BY OTHERS
TB1
A6A5A4A3A2A1VOUTT/C+VCOM
10987654321
PRP-31316-02PRP-31316-02PRP-31316-02PRP-31316-02PRP-31316-02PRP-31316-02
N/CWHITE
REDBLACK
ANALOG / DMX STATION TERMINATION REFERENCE
CONNECT ASDESIRED TOTERMINALS ONAPPROPRIATEANALOGSTATION.
CONTROL FORCHANNELS 1THRU 12 SHOWN.
CONNECTEDANALOGCHANNELSWILL GO TOFULL WHENPANIC SWITCHIS PRESSED
WIRE NUTAS REQUIREDBY OTHERS
PRP-31316-02 IS CALLED OUT SEPERATELY.SHOWN HERE FOR REFERENCE ONLY.
GREEN
TB1
A12A11A10A9A8A7
654321
PRP-31316-02PRP-31316-02PRP-31316-02PRP-31316-02PRP-31316-02PRP-31316-02
TB2
ANALOGCONTROLHARNESSTO OTHERSTATIONS
OR TO0-10V DIMMERS
SIDE VIEW
EL
EC
TR
ON
ICS
TE
RM
INA
L B
LO
CK BEST
K/OACCESS
BESTK/O
ACCESS
FAIRK/O
ACCESS
NO K/OACCESS
FAIRK/OACCESS
FAIRK/OACCESS
FAIRK/O
ACCESS
2 GANG3-1/2" DEEPBACK BOXBY OTHERS
5/16"
3 1/2"
1"
Page 32 of 40
User Guide
Leviton Remembrance Control Stations
Panic Station (Cat. No. 011-RMB81-022)
PANIC
Remembrance
FRONT VIEW
REAR VIEW
VOUTT/C+VCOM
4321
GREENWHITEREDBLACK
ALPHA1898/4C
BY OTHERS
TB1
A6A5A4A3A2A1VOUTT/C+VCOM
10987654321
PRP-31316-02PRP-31316-02PRP-31316-02PRP-31316-02PRP-31316-02PRP-31316-02
N/CN/C
REDBLACK
ANALOG / DMX STATION TERMINATION REFERENCE
CONNECT ASDESIRED TOTERMINALS ONAPPROPRIATEANALOGSTATION.
CONTROL FORCHANNELS 1THRU 12 SHOWN.
CONNECTEDANALOGCHANNELSWILL GO TOFULL WHENPANIC SWITCHIS PRESSED
WIRE NUTAS REQUIREDBY OTHERS
PRP-31316-02 IS CALLED OUT SEPERATELY.SHOWN HERE FOR REFERENCE ONLY.
GREENWHITENOT USED
TB1
A12A11A10A9A8A7
654321
PRP-31316-02PRP-31316-02PRP-31316-02PRP-31316-02PRP-31316-02PRP-31316-02
TB2
ANALOGCONTROLHARNESSTO OTHERSTATIONS
OR TO0-10V DIMMERS
SIDE VIEW
EL
EC
TR
ON
ICS
TE
RM
INA
L B
LO
CK BEST
K/OACCESS
BESTK/O
ACCESS
FAIRK/O
ACCESS
NO K/OACCESS
FAIRK/OACCESS
FAIRK/OACCESS
FAIRK/O
ACCESS
2 GANG3-1/2" DEEPBACK BOXBY OTHERS
5/16"
3 1/2"
1"
Page 33 of 40
User Guide
Leviton Remembrance Control Stations
4 Channel DMX-512 Station (Cat. No. 017-RMB81-104)
REAR VIEW
A6A5A4A3A2A1VOUTT/C+VCOM
10987654321
YELLOWBROWNBLUEORANGENO CONNECTWHITEREDBLACK
GREEN-VOUT FROMENTRY STATION /PANIC STATION
ALPHA1898/18C
BY OTHERS
BELDEN 9829BY OTHERS
18 GAUGE 600V WIREBY OTHERS
EDWARDS #590DORMEYER #DCT 5-120OTHERS MAY APPLY
120 VACBY OTHERS
BELDEN 9829BY OTHERS
DMX-512 INFROM CONSOLE
5 PIN XLRFRONT VIEW
PUSH
TO DIMMER RACKDMX-512 OUT
5 PIN XLRFRONT VIEW
TB1
TB3
ANALOGCONTROLHARNESSTO OTHERSTATIONS
OR TO0-10V DIMMERS
DMX-512 START ADDRESS(CHANNEL MODE ONLY)
DRAIN WIREWHITE/BLUEBLUE/WHT
DRAIN WIREWHITE/BLUEBLUE/WHT
SHIELDDATA-DATA+
GNDDMX-DMX+GNDDMX-DMX+RECLAC1AC2
987654321
DRAIN WIREWHITE/BLUEBLUE/WHTDRAIN WIREWHITE/BLUEBLUE/WHTD
MX
OU
TD
MX
IN
154 23
1 542 3
10 VAC 5VA
LISTED CLASS 2
TRANSFORMER
BY OTHERS
MASTER
ON / OFF
Remembrance
FRONT VIEW
SIDE VIEW
EL
EC
TR
ON
ICS
MO
DU
LE
TE
RM
INA
L B
LO
CK BEST
K/OACCESS
BESTK/O
ACCESS
FAIRK/O
ACCESS
FAIRK/OACCESS
FAIRK/OACCESS
FAIRK/O
ACCESS
8 GANG3-1/2" DEEPBACK BOXBY OTHERS
5/16"
3 1/2"
1 1/2"
2"
NO K/O ACCESS
LED
BLINKING RED = RECORD MODE
BLINKING YELLOW = PLAY MODE WITH ACTIVE DMX-512 IN AND RECORD ENABLED
BLINKING GREEN = PLAY MODE WITH ACTIVE DMX-512 IN AND RECORD DISABLED OR CHANNEL MODE
SOLID GREEN = PLAY MODE WITH NO DMX IN AND RECORD DISABLED OR CHANNEL MODE
SOLID YELLOW = PLAY MODE WITH NO DMX IN AND RECORD ENABLED
DIAGNOSTICLED
FUNCTION
LED
Note:Terminal Blocksare plugable
JUMPER SETTINGS
JP1 * OFF = SCENE SAVER MODEON = CHANNEL MODE
JP2 * OFF = RECORD ENABLE (SS MODE ONLY)ON = RECORD LOCKOUT (SS MODE ONLY)
JP3 * OFF = STATION ALWAYS OUTPUTS DMX-512ON = NO DMX OUTPUT WHEN STATION IS OFF
JP4 * OFF = CHANNEL MODE SINGLE SEQUENCEON = CHANNEL MODE DUAL REPEAT SEQUENCE
JP5 * OFF = CHANNELS PILE ONTO DMX-512 INON = CHANNELS REPLACE DMX-512 IN LVLS.
JP6 * OFF = 6 CHANNEL STATIONON = 4 CHANNEL STATION
JP7 RESERVED
* DEFAULT SETTING
Page 34 of 40
User Guide
Leviton Remembrance Control Stations
6 Channel DMX-512 Station (Cat. No. 018-RMB81-106)
REAR VIEW
A6A5A4A3A2A1VOUTT/C+VCOM
10987654321
GRAYVIOLETYELLOWBROWNBLUEORANGENO CONNECTWHITEREDBLACK
GREEN-VOUT FROMENTRY STATION /PANIC STATION
ALPHA1898/10C
BY OTHERS
BELDEN 9829BY OTHERS
18 GAUGE 600V WIREBY OTHERS
EDWARDS #590DORMEYER #DCT 5-120OTHERS MAY APPLY
120 VACBY OTHERS
BELDEN 9829BY OTHERS
DMX-512 INFROM CONSOLE
5 PIN XLRFRONT VIEW
TO DIMMER RACKDMX-512 OUT
5 PIN XLRFRONT VIEW
TB1
TB3
ANALOGCONTROLHARNESSTO OTHERSTATIONS
OR TO0-10V DIMMERS
DMX-512 START ADDRESS(CHANNEL MODE ONLY)
DRAIN WIREWHITE/BLUEBLUE/WHT
DRAIN WIREWHITE/BLUEBLUE/WHT
SHIELDDATA-DATA+
GNDDMX-DMX+GNDDMX-DMX+RECLAC1AC2
987654321
DRAIN WIREWHITE/BLUEBLUE/WHTDRAIN WIREWHITE/BLUEBLUE/WHTD
MX
OU
TD
MX
IN
154 23
1 542 3
10 VAC 5VA
LISTED CLASS 2
TRANSFORMER
BY OTHERS
MASTER
ON / OFF
Remembrance
FRONT VIEW
PUSH
SIDE VIEW
EL
EC
TR
ON
ICS
MO
DU
LE
TE
RM
INA
L B
LO
CK BEST
K/OACCESS
BESTK/O
ACCESS
FAIRK/O
ACCESS
FAIRK/OACCESS
FAIRK/OACCESS
FAIRK/O
ACCESS
8 GANG3-1/2" DEEPBACK BOXBY OTHERS
5/16"
3 1/2"
1 1/2"
2"
NO K/O ACCESS
LED
BLINKING RED = RECORD MODE
BLINKING YELLOW = PLAY MODE WITH ACTIVE DMX-512 IN AND RECORD ENABLED
BLINKING GREEN = PLAY MODE WITH ACTIVE DMX-512 IN AND RECORD DISABLED OR CHANNEL MODE
SOLID GREEN = PLAY MODE WITH NO DMX IN AND RECORD DISABLED OR CHANNEL MODE
SOLID YELLOW = PLAY MODE WITH NO DMX IN AND RECORD ENABLED
DIAGNOSTICLED
FUNCTION
LED
Note:Terminal Blocksare plugable
JUMPER SETTINGS
JP1 * OFF = SCENE SAVER MODEON = CHANNEL MODE
JP2 * OFF = RECORD ENABLE (SS MODE ONLY)ON = RECORD LOCKOUT (SS MODE ONLY)
JP3 * OFF = STATION ALWAYS OUTPUTS DMX-512ON = NO DMX OUTPUT WHEN STATION IS OFF
JP4 * OFF = CHANNEL MODE SINGLE SEQUENCEON = CHANNEL MODE DUAL REPEAT SEQUENCE
JP5 * OFF = CHANNELS PILE ONTO DMX-512 INON = CHANNELS REPLACE DMX-512 IN LVLS.
JP6 * OFF = 6 CHANNEL STATIONON = 4 CHANNEL STATION
JP7 RESERVED
* DEFAULT SETTING
Page 35 of 40
User Guide
Leviton Remembrance Control Stations
12 C
han
nel
DM
X-5
12 S
tati
on
(Cat
. No
. 019
-RM
B81
-112
)
MA
ST
ER
ON
/ O
FF
Remembrance
FR
ON
T V
IEW
RE
AR
VIE
W
A12
A11
A10
A9
A8
A7
A6
A5
A4
A3
A2
A1
VOUT
T/C
+V COM
10 9 8 7 6 5 4 3 2 1
GR
AY
VIO
LE
TY
EL
LO
WB
RO
WN
BL
UE
OR
AN
GE
NO
CO
NN
EC
TW
HIT
ER
ED
BL
AC
K
GR
EE
N-V
OU
T F
RO
ME
NT
RY
STA
TIO
N /
PAN
IC S
TAT
ION
AL
PH
A18
98/1
6CB
Y O
TH
ER
S
BE
LD
EN
982
9B
Y O
TH
ER
S
18 G
AU
GE
600
V W
IRE
BY
OT
HE
RS
ED
WA
RD
S #
590
DO
RM
EY
ER
#D
CT
5-1
20O
TH
ER
S M
AY
AP
PLY
120
VAC
BY
OTH
ERS
BE
LD
EN
982
9B
Y O
TH
ER
SB
EL
DE
N 9
829
BY
OT
HE
RS
DM
X-5
12 IN
FR
OM
CO
NS
OL
E
5 P
IN X
LR
FR
ON
T V
IEW
TO D
IMM
ER
RA
CK
DM
X-5
12 O
UT
5 P
IN X
LR
FR
ON
T V
IEW
WH
T/B
LK
RE
D/B
LK
RE
D/Y
EL
RE
D/G
RN
TAN
PIN
K
6 5 4 3 2 1
TB
1
TB
3T
B3
TB
2
AN
AL
OG
CO
NT
RO
LH
AR
NE
SS
TO O
TH
ER
STA
TIO
NS
OR
TO
0-10
V D
IMM
ER
S
DM
X-5
12 S
TAR
T A
DD
RE
SS
(CH
AN
NE
L M
OD
E O
NLY
)D
MX
-512
STA
RT
AD
DR
ES
S(C
HA
NN
EL
MO
DE
ON
LY)
GN
DD
MX
-D
MX
+G
ND
DM
X-
DM
X+
RE
CL
AC
1A
C2
9 8 7 6 5 4 3 2 1
DR
AIN
WIR
EW
HIT
E/B
LU
EB
LU
E/W
HT
DR
AIN
WIR
EW
HIT
E/B
LU
EB
LU
E/W
HT
DMXOUT
DMXIN
DR
AIN
WIR
EW
HIT
E/B
LU
EB
LU
E/W
HT
DR
AIN
WIR
EW
HIT
E/B
LU
EB
LU
E/W
HT
SH
IEL
DD
ATA
-D
ATA
+
GN
DD
MX
-D
MX
+G
ND
DM
X-
DM
X+
RE
CL
AC
1A
C2
9 8 7 6 5 4 3 2 1
DR
AIN
WIR
EW
HIT
E/B
LU
EB
LU
E/W
HT
DR
AIN
WIR
EW
HIT
E/B
LU
EB
LU
E/W
HT
DMXOUT
DMXIN
15 4
23
15 4
23
10 V
AC
5VA
LIS
TE
D C
LA
SS
2
TR
AN
SFO
RM
ER
BY
OTH
ER
S
PUSH
SID
E V
IEW
ELECTRONICSMODULE
TERMINAL BLOCK
BE
ST
K/O
AC
CE
SS
BE
ST
K/O
AC
CE
SS
FAIR
K/O
AC
CE
SS
FAIR
K/O
AC
CE
SS
FAIR
K/O
AC
CE
SS
FAIR
K/O
AC
CE
SS
8 G
AN
G3-
1/2"
DE
EP
BA
CK
BO
XB
Y O
TH
ER
S
5/16
"
3 1/
2"
1 1/
2"
2"
NO
K/O
AC
CE
SS
LE
DL
ED
BL
INK
ING
RE
D=
RE
CO
RD
MO
DE
BL
INK
ING
YE
LL
OW
= P
LA
Y M
OD
E W
ITH
A
CT
IVE
DM
X-5
12 IN
A
ND
RE
CO
RD
EN
AB
LE
D
BL
INK
ING
GR
EE
N=
PL
AY
MO
DE
WIT
H
AC
TIV
E D
MX
-512
IN
AN
D R
EC
OR
D D
ISA
BL
ED
O
R C
HA
NN
EL
MO
DE
SO
LID
GR
EE
N=
PL
AY
MO
DE
WIT
H
NO
DM
X IN
AN
D
RE
CO
RD
DIS
AB
LE
D
OR
CH
AN
NE
L M
OD
E
SO
LID
YE
LL
OW
= P
LA
Y M
OD
E W
ITH
N
O D
MX
IN A
ND
R
EC
OR
D E
NA
BL
ED
DIA
GN
OS
TIC
LE
DF
UN
CT
ION
LE
D
No
te:
Term
inal
Blo
cks
are
plu
gab
le
No
te:
Term
inal
Blo
cks
are
plu
gab
le
JUM
PE
R S
ET
TIN
GS
JP1
* O
FF
= S
CE
NE
SA
VE
R M
OD
EO
N=
CH
AN
NE
L M
OD
E
JP2
* O
FF
= R
EC
OR
D E
NA
BL
E (
SS
MO
DE
ON
LY)
ON
= R
EC
OR
D L
OC
KO
UT
(S
S M
OD
E O
NLY
)
JP3
* O
FF
= S
TAT
ION
ALW
AY
S O
UT
PU
TS
DM
X-5
12O
N=
NO
DM
X O
UT
PU
T W
HE
N S
TAT
ION
IS O
FF
JP4
* O
FF
= C
HA
NN
EL
MO
DE
SIN
GL
E S
EQ
UE
NC
EO
N=
CH
AN
NE
L M
OD
E D
UA
L R
EP
EA
T S
EQ
UE
NC
E
JP5
* O
FF
= C
HA
NN
EL
S P
ILE
ON
TO D
MX
-512
INO
N=
CH
AN
NE
LS
RE
PL
AC
E D
MX
-512
IN L
VL
S.
JP6
* O
FF
= 6
CH
AN
NE
L S
TAT
ION
ON
= 4
CH
AN
NE
L S
TAT
ION
JP7
RE
SE
RV
ED
* D
EFA
ULT
SE
TT
ING
Page 36 of 40
User Guide
Leviton Remembrance Control Stations
0-10V Analog Dimmer
ALPHA# 1898
BY OTHERS
ANALOGCONTROLHARNESS
FROMANALOG
STATION(S)
ORANGEBLUEBROWNYELLOWVIOLETGRAYPINKTANRED/GRNRED/YELRED/BLKWHT/BLK
BLACK
WHITENOT USEDGREENNOT USED
RED
131415161718192021222324600+V600TC2TC3TC4
123456789101112600600
ALPHA# 1898
BY OTHERS
ANALOGCONTROLHARNESS
FROMANALOG
STATION(S)
ORANGEBLUEBROWNYELLOW
BLACK
WHITENOT USED
GREENNOT USED
RED
1234
COMCOM
DMX-DMX-DMX+DMX+MCPXMCPX+15V+15VREM+REM+REM-REM-
1234
COMCOM
ALPHA# 1898
BY OTHERS
ANALOGCONTROLHARNESS
FROMANALOG
STATION(S)
INLEDGND
BLACKRED
ORANGEBLUE
BROWNYELLOW
VIOLETGRAYPINKTAN
1234567891011121314151617181920
1K OHMSGREENVOUT
CONTROLIN
PANIC
HOUSELIGHTS
WHITENOT USED
BLACKREDGREENWHITE
PN2222ABOTTOM VIEW
CAT. NO. 011-RMB81-22
BEC
NOTE:CONNECT GREEN WIRE TOVOUT ON ANALOG STATIONSFOR THIS APPLICATION ONLY.
PANIC
Remembrance
NSI Cat. No. N24081:1 DIMMER
TERMINATION
Colortran Model ENR 12 OR 24 withUniversal Control Module # 166-902 (3)
1:1 (1-12) DIMMER TERMINATION
Colortran Model ENR 968 Channel Houselight
DIMMER TERMINATION
Page 37 of 40
User Guide
Leviton Remembrance Control Stations
Page 38 of 40
User Guide
Leviton Remembrance Control Stations
LIMITED TWO YEAR WARRANTY AND EXCLUSIONS
Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this productat the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper usefor two years from the purchase date. Leviton’s only obligation is to correct such defects by repair orreplacement, at its option, if within such two year period the product is returned prepaid, with proof of purchasedate, and a description of the problem to Leviton Manufacturing Co., Inc., Att: Service Department,20497 SW Teton Ave., Tualatin, Oregon 97062. All products returned to Leviton-NSI must have factoryauthorization for return prior to shipping. The purchaser is responsible for completing and mailing to Leviton,within 15 days of purchase, the warranty registration card enclosed with each product. This warranty excludesand there is disclaimed liability for labor for removal of this product or reinstallation. This warranty is void ifthis product is installed improperly or in an improper environment, overloaded, misused, opened, abused, oraltered in any manner, or is not used under normal operating conditions or not in accordance with any labelsor instructions. There are no other or implied warranties of any kind, including merchantability and fitness fora particular purpose, but if any implied warranty is required by the applicable jurisdiction, the duration of anysuch implied warranty, including merchantability and fitness for a particular purpose, is limited to two years.Leviton is not liable for incidental, indirect, special, or consequential damages, including without limitation,damage to, or loss of use of, any equipment, lost sales or profits or delay or failure to perform this warrantyobligation. The remedies provided herein are the exclusive remedies under this warranty, whether based oncontract, tort or otherwise.
WARRANTY
Page 39 of 40
User Guide
Leviton Remembrance Control Stations
Page 40 of 40
User Guide
Leviton Remembrance Control StationsPK-93382-00-01-1B
Leviton NSI Division Headquarters20497 SW Teton Avenue, Tualatin, OR 97062
Customer Service Telephone: 800.736.6682Customer Service Fax: 503.404.5594Technical Services: 800.959.6004
Leviton Manufacturing Company, Incorporated59-25 Little Neck Parkway, Little Neck, NY 11362-2591
Visit Leviton’s websites at http://www.nsicorp.com & http://www.leviton.com
Copyright® 2003. Leviton Manufacturing Company, Inc. All Rights ReservedSpecifications and pricing subject to change at any time.