Relining a bore_part3

50
Bore Casing & Screens Pipes & Components Environmental Drilling Water Treatment Safety Products Sand Spears Pumps How To: Ph 1300 133 000 Reline a Standard Bore Why have a new bore drilled when you can repair your old bore Part 3

description

If you are looking at relining your water bore, due to the steel bore casing being corroded away and leaving holes in the side that can allow sand or dirt to enter the bore. This video will help you install the casing and screen add a gravel pack and develop the screen after you have gathered the information needed to start relining your bore.

Transcript of Relining a bore_part3

Page 1: Relining a bore_part3

Bore Casing & Screens Pipes & Components Environmental Drilling Water Treatment Safety Products Sand Spears Pumps

How To:

Ph 1300 133 000

Reline a Standard Bore

Why have a new bore drilled when you can repair your old bore

Part 3

Page 2: Relining a bore_part3

Bore Casing & Screens Pipes & Components Environmental Drilling Water Treatment Safety Products Sand Spears Pumps

How To

Ph 1300 133 000

Now that we have all the details we can start

to reline our bore

Page 3: Relining a bore_part3

Bore Casing & Screens Pipes & Components Environmental Drilling Water Treatment Safety Products Sand Spears Pumps

How To

Ph 1300 133 000

Our Dimensions are – 1 - 145mm I.D (Inside Diameter)

2 - Casing Depth 30m

Page 4: Relining a bore_part3

Bore Casing & Screens Pipes & Components Environmental Drilling Water Treatment Safety Products Sand Spears Pumps

How To

Ph 1300 133 000

3 - Old Steel Screen

4 - Screen 6m long

Page 5: Relining a bore_part3

Bore Casing & Screens Pipes & Components Environmental Drilling Water Treatment Safety Products Sand Spears Pumps

How To

Ph 1300 133 000

5- Slot Size or Aperture of Screen is Unknown

Page 6: Relining a bore_part3

Bore Casing & Screens Pipes & Components Environmental Drilling Water Treatment Safety Products Sand Spears Pumps

How To

Ph 1300 133 000

We can use 125CL12 UPVC

Threaded Casing

The above pipe has a 140mm O.D –Outside

Diameter

Page 7: Relining a bore_part3

Bore Casing & Screens Pipes & Components Environmental Drilling Water Treatment Safety Products Sand Spears Pumps

How To

Ph 1300 133 000

Materials Needed

Page 8: Relining a bore_part3

Bore Casing & Screens Pipes & Components Environmental Drilling Water Treatment Safety Products Sand Spears Pumps

How To

Ph 1300 133 000

The casing and screen can

be 3m or 6m long.

This depends on the

height of your Gantry or

Tripod

Page 9: Relining a bore_part3

Bore Casing & Screens Pipes & Components Environmental Drilling Water Treatment Safety Products Sand Spears Pumps

How To

Ph 1300 133 000

If they are to be 3m, then

double the amount as

needed below

Page 10: Relining a bore_part3

Bore Casing & Screens Pipes & Components Environmental Drilling Water Treatment Safety Products Sand Spears Pumps

How To

Ph 1300 133 000

7 Lengths of 125

CL12 UPVC Casing

Pipe by 6m Threaded

Male/Female

Page 11: Relining a bore_part3

Bore Casing & Screens Pipes & Components Environmental Drilling Water Treatment Safety Products Sand Spears Pumps

How To

Ph 1300 133 000

1 Length of 125 CL12

UPVC Screen with

0.8mm slots (aperture)

Pipe by 6m.

Threaded Female one

end and a bottom cap

on the other.

Page 12: Relining a bore_part3

Bore Casing & Screens Pipes & Components Environmental Drilling Water Treatment Safety Products Sand Spears Pumps

Ph 1300 133 000

3 bags 8/16 Sand

(Number of bags depends

on Dia. of original bore)Go to

http://deps.com.au/handy-links/calculators

For calculating number of bags

Page 13: Relining a bore_part3

Bore Casing & Screens Pipes & Components Environmental Drilling Water Treatment Safety Products Sand Spears Pumps

How To

Ph 1300 133 000

Equipment Needed

Page 14: Relining a bore_part3

Bore Casing & Screens Pipes & Components Environmental Drilling Water Treatment Safety Products Sand Spears Pumps

How To

Ph 1300 133 000

Lifting Piece

Or Weld lugs

Or Drill Holes For rope or Slings

Page 15: Relining a bore_part3

Bore Casing & Screens Pipes & Components Environmental Drilling Water Treatment Safety Products Sand Spears Pumps

How To

Ph 1300 133 000

Casing Clamp

Page 16: Relining a bore_part3

Bore Casing & Screens Pipes & Components Environmental Drilling Water Treatment Safety Products Sand Spears Pumps

How To

Ph 1300 133 000

Lifting Gantry

Page 17: Relining a bore_part3

Bore Casing & Screens Pipes & Components Environmental Drilling Water Treatment Safety Products Sand Spears Pumps

How To

Ph 1300 133 000

Installation of

Screen And Casing

Page 18: Relining a bore_part3

Bore Casing & Screens Pipes & Components Environmental Drilling Water Treatment Safety Products Sand Spears Pumps

How To

Ph 1300 133 000

Set Tripod or

Gantry

over the

borehole

Step 1

Page 19: Relining a bore_part3

Bore Casing & Screens Pipes & Components Environmental Drilling Water Treatment Safety Products Sand Spears Pumps

How To

Ph 1300 133 000

Screw in Lifting

Piece to the screen(screen should have female

thread)

Step 2

Page 20: Relining a bore_part3

Bore Casing & Screens Pipes & Components Environmental Drilling Water Treatment Safety Products Sand Spears Pumps

How To

Ph 1300 133 000

Connect Lifting

piece

to the crane and lift

Screen into the air

and lower the

screen into the hole

Step 3

Page 21: Relining a bore_part3

Bore Casing & Screens Pipes & Components Environmental Drilling Water Treatment Safety Products Sand Spears Pumps

How To

Ph 1300 133 000

Lower screen to

approx 500mm above

ground

and tighten

Casing clamp

Step 4

Page 22: Relining a bore_part3

Bore Casing & Screens Pipes & Components Environmental Drilling Water Treatment Safety Products Sand Spears Pumps

How To

Ph 1300 133 000

This holds the casing

stem in place while

the next piece of

casing is screwed into

place.

Step 4

Page 23: Relining a bore_part3

Bore Casing & Screens Pipes & Components Environmental Drilling Water Treatment Safety Products Sand Spears Pumps

How To

Ph 1300 133 000

If the clamp is not tight

enough the casing and

screen may slip through

clamp and fall to the

bottom of the bore.

A disaster.

Step 4

Page 24: Relining a bore_part3

Bore Casing & Screens Pipes & Components Environmental Drilling Water Treatment Safety Products Sand Spears Pumps

How To

Ph 1300 133 000

When clamp is tight

to hold the screen,

release crane and

remove the lifting

piece

Step 5

Page 25: Relining a bore_part3

Bore Casing & Screens Pipes & Components Environmental Drilling Water Treatment Safety Products Sand Spears Pumps

How To

Ph 1300 133 000

Screw the lifting

piece into the

casing and lift into

the air.

Step 6

Page 26: Relining a bore_part3

Bore Casing & Screens Pipes & Components Environmental Drilling Water Treatment Safety Products Sand Spears Pumps

How To

Ph 1300 133 000

Lower casing to just

above the screen,

gently lower and

turn the casing

while lowering

Step 7

Page 27: Relining a bore_part3

Bore Casing & Screens Pipes & Components Environmental Drilling Water Treatment Safety Products Sand Spears Pumps

How To

Ph 1300 133 000

Lower to thread starts

and then keep turning

and lowering, until the

thread

is to the shoulder

Step 8

Page 28: Relining a bore_part3

Bore Casing & Screens Pipes & Components Environmental Drilling Water Treatment Safety Products Sand Spears Pumps

How To

Ph 1300 133 000

Tighten thread with

a pipe wrench.

( not to tight as pipe is Pvc not steel)

Step 9

Page 29: Relining a bore_part3

Bore Casing & Screens Pipes & Components Environmental Drilling Water Treatment Safety Products Sand Spears Pumps

How To

Ph 1300 133 000

Take up any slack

on the lifting rope

Step 10

Page 30: Relining a bore_part3

Bore Casing & Screens Pipes & Components Environmental Drilling Water Treatment Safety Products Sand Spears Pumps

How To

Ph 1300 133 000

Release casing

clamp

Step 11

Page 31: Relining a bore_part3

Bore Casing & Screens Pipes & Components Environmental Drilling Water Treatment Safety Products Sand Spears Pumps

How To

Ph 1300 133 000

Lower casing pipe

to approximately

500mm above

ground

Step 12

Page 32: Relining a bore_part3

Bore Casing & Screens Pipes & Components Environmental Drilling Water Treatment Safety Products Sand Spears Pumps

How To

Ph 1300 133 000

Tighten

Casing Clamp

Step 13

Page 33: Relining a bore_part3

Bore Casing & Screens Pipes & Components Environmental Drilling Water Treatment Safety Products Sand Spears Pumps

How To

Ph 1300 133 000

Repeat steps 6 -

13

Step 14

Page 34: Relining a bore_part3

Bore Casing & Screens Pipes & Components Environmental Drilling Water Treatment Safety Products Sand Spears Pumps

How To

Ph 1300 133 000

Until the Screen

sits on the

bottom

of the bore

Step 15

Page 35: Relining a bore_part3

Bore Casing & Screens Pipes & Components Environmental Drilling Water Treatment Safety Products Sand Spears Pumps

How To

Ph 1300 133 000

Release the rope

and remove

lifting piece

Step 16

Page 36: Relining a bore_part3

Bore Casing & Screens Pipes & Components Environmental Drilling Water Treatment Safety Products Sand Spears Pumps

How To

Ph 1300 133 000

Cut the casing

sticking up to as

close to the

ground, to suit

your installation

Step 17

Page 37: Relining a bore_part3

Bore Casing & Screens Pipes & Components Environmental Drilling Water Treatment Safety Products Sand Spears Pumps

How To

Ph 1300 133 000

If you do not know the size of

the screen or the Gravel Pack

Step 18

Page 38: Relining a bore_part3

Bore Casing & Screens Pipes & Components Environmental Drilling Water Treatment Safety Products Sand Spears Pumps

How To

Ph 1300 133 000

Then pore the 8/16 sand

around the Pvc screen to

use this as a Gravel pack

Step 18

Page 39: Relining a bore_part3

Bore Casing & Screens Pipes & Components Environmental Drilling Water Treatment Safety Products Sand Spears Pumps

How To

Ph 1300 133 000

The bore may need to be

developed if the sand gravel

pack has been used.

Step 19

Page 40: Relining a bore_part3

Bore Casing & Screens Pipes & Components Environmental Drilling Water Treatment Safety Products Sand Spears Pumps

How To

Ph 1300 133 000

This can be done in a various

number of ways

Page 41: Relining a bore_part3

Bore Casing & Screens Pipes & Components Environmental Drilling Water Treatment Safety Products Sand Spears Pumps

How To

Ph 1300 133 000

1: Use a air compressor

by putting a air line

to the bottom of the well.

www.howiepumpservice.com

Page 42: Relining a bore_part3

Bore Casing & Screens Pipes & Components Environmental Drilling Water Treatment Safety Products Sand Spears Pumps

How To

Ph 1300 133 000

And using the air

to lift all the fines

that may of come

into the screen.

Page 43: Relining a bore_part3

Bore Casing & Screens Pipes & Components Environmental Drilling Water Treatment Safety Products Sand Spears Pumps

How To

Ph 1300 133 000

2: By placing a pump in the

Bore,

and pump for a period of time

Page 44: Relining a bore_part3

Bore Casing & Screens Pipes & Components Environmental Drilling Water Treatment Safety Products Sand Spears Pumps

How To

Ph 1300 133 000

This method will wear the pump

very quickly as the water may

contain a large amount of sand

in it.

Page 45: Relining a bore_part3

Bore Casing & Screens Pipes & Components Environmental Drilling Water Treatment Safety Products Sand Spears Pumps

How To

Ph 1300 133 000

3: Use a

Surge block.

This is were a pipe is lifted and lowered

continuously push the sand backward and

forward.

www.ectmfg.com

Page 46: Relining a bore_part3

Bore Casing & Screens Pipes & Components Environmental Drilling Water Treatment Safety Products Sand Spears Pumps

How To

Ph 1300 133 000

If the Bore you are Relining only needs casing and to join to the original screen , then go to Part 4 of this presentation.

Go to or Click on Link below

www.deps.com.au/how-to/relining_a_bore_part4

Page 47: Relining a bore_part3

Thank you for taking the time to look at the information we have created for you,We hope this will be of assistance to solving your piping, drainage and drilling challenges.

If you have any more questionsPlease feel free to contact myself or one of our team

Bore Casing & Screens Pipes & Components Environmental Drilling Water Treatment Safety Products Sand Spears Pumps

Article

Page 48: Relining a bore_part3

Bore Casing & Screens Pipes & Components Environmental Drilling Water Treatment Safety Products Sand Spears Pumps

For more Case Studies, How to, Articles and Information

go to www.deps.com.authen click onto Handy Links

or contact us on1300 133 000

[email protected]

Case Study - How to - Articles

Ph 1300 133 000

Page 49: Relining a bore_part3

SlottingCuttingFabricatingPipe TestingPerforationDrawingsSpear PointsSafetyPumpsBore Casing & Screens Pipes & Components Environmental Drilling Water Treatment

Safety Products Sand Spears Pumps

Deps Products & Capabilities

ThreadingTurningWeldingSlitting

DesigningWater

TreatmentPipe

Drilling products

Pipe FittingsPh 1300 133

000

Page 50: Relining a bore_part3

Bore Casing & Screens Pipes & Components Environmental Drilling Water Treatment Safety Products Sand Spears Pumps

Ph 1300 133 000

Solving your Piping,

Drilling and Drainage

Challenges

with Trust and Integrity