Release Notes for RISA-3D Version 11.0.2 Enhancements/Corrections Enhancements/Corrections Enhanced modeling with wood materials: Revised dialogs for selecting and adding wood materials to be more user‐friendly. Easier access to the Custom Wood Materials spreadsheet. New dialogs allow the user to view/confirm the material design properties. Updated the structural composite lumber design lists so that shape selections match proprietary products. Added the U.K. National Annex provisions to the 2005 EuroCode Hot‐Rolled steel design (NA to BS EN 1993‐1‐ 1:2005). Custom moving loads are now save with the input file. Improved animation window controls. Added automatic save of RISAFloor results when transferring a model from RISAFloor to RISA‐3D. Improved the accuracy of CSA S16‐09 member capacity calculations for Class 3 and Class 4 members. Updated the display of the units for Mass. Corrected a bug in Cold‐Formed Cb calculations where Cb could change (conservatively) in a non‐AISC Hot‐ Rolled steel code was selected. Corrected an error in the CF factor calculation for 12" wide members. Corrected a problem with deleting distributed loads using a spreadsheet. Updated the masonry P‐Little Delta procedure to properly account for all support conditions. Corrected an issue where 64‐bit network clients were not displaying the Key ID in the Help‐About dialog. Fixed values for H and HN sections in the Chilean Steel shapes database. Corrected a member optimization issue in RISA‐3D under RISAFloor where RISA‐3D would not recommend smaller shapes for members which were now well below failing due to a decrease in loads. Corrected an issue with the Australian steel code where members with axial force greater than Euler buckling capacity would calculate a negative moment capacity. Fixed a refreshing issue with General shapes where they would not show up within the "Assign Shape Directly" dialog. Corrected a bug in which sorting the member force results for a concrete member would cause the detail report force diagram to change. Fixed an issue with concrete and masonry walls where the code check would incorrectly produce "INF" or some design forces could be reported as zero. Fixed an issue that didn't remember user entered seismic Ta for Canadian codes. Corrected DXF grids import to include arcs. Corrected errors in the Chinese shape database for the following shapes: TM170X250 and TW150X300A. Corrected a problem with reading CIS/2 files containing quotation marks. Fixed an issue with the Cm calculation for out of plane concrete wall design. The program was previously using a value of 0.6 when it should have been using 1.0. Fixed an issue that caused a major error while using the Out‐of‐Plane‐Flip tool on a wall panel. Fixed a tolerance issue which could cause the seismic self‐weight calculation to be incorrect when member area loads are used as part of the self‐weight. Corrected an issue where h/w ratios for wood walls with multiple openings could be calculated incorrectly for the FTAO design method. Corrected a problem with exporting models using Rigid Links to DXF. Removed "Trimmer" from wood wall opening detail reports, as it had no impact on the design. Fixed a units issue with the Deflection Ratio value on the detail report for out of plane concrete wall design. Previously this ratio was conservatively off by a factor of 12.

description

VZ

Transcript of Release Notes 3D

Page 1: Release Notes 3D

Release Notes for RISA-3D

Version 11.0.2 Enhancements/Corrections

Enhancements/Corrections

Enhancedmodelingwithwoodmaterials: Reviseddialogsforselectingandaddingwoodmaterialstobemoreuser‐friendly. EasieraccesstotheCustomWoodMaterialsspreadsheet. Newdialogsallowtheusertoview/confirmthematerialdesignproperties. Updatedthestructuralcompositelumberdesignlistssothatshapeselectionsmatchproprietary

products. AddedtheU.K.NationalAnnexprovisionstothe2005EuroCodeHot‐Rolledsteeldesign(NAtoBSEN1993‐1‐

1:2005). Custommovingloadsarenowsavewiththeinputfile. Improvedanimationwindowcontrols. AddedautomaticsaveofRISAFloorresultswhentransferringamodelfromRISAFloortoRISA‐3D. ImprovedtheaccuracyofCSAS16‐09membercapacitycalculationsforClass3andClass4members. UpdatedthedisplayoftheunitsforMass. CorrectedabuginCold‐FormedCbcalculationswhereCbcouldchange(conservatively)inanon‐AISCHot‐

Rolledsteelcodewasselected. CorrectedanerrorintheCFfactorcalculationfor12"widemembers. Correctedaproblemwithdeletingdistributedloadsusingaspreadsheet. UpdatedthemasonryP‐LittleDeltaproceduretoproperlyaccountforallsupportconditions. Correctedanissuewhere64‐bitnetworkclientswerenotdisplayingtheKeyIDintheHelp‐Aboutdialog. FixedvaluesforHandHNsectionsintheChileanSteelshapesdatabase. CorrectedamemberoptimizationissueinRISA‐3DunderRISAFloorwhereRISA‐3Dwouldnotrecommend

smallershapesformemberswhichwerenowwellbelowfailingduetoadecreaseinloads. CorrectedanissuewiththeAustraliansteelcodewherememberswithaxialforcegreaterthanEulerbuckling

capacitywouldcalculateanegativemomentcapacity. FixedarefreshingissuewithGeneralshapeswheretheywouldnotshowupwithinthe"AssignShapeDirectly"

dialog. Correctedabuginwhichsortingthememberforceresultsforaconcretememberwouldcausethedetail

reportforcediagramtochange. Fixedanissuewithconcreteandmasonrywallswherethecodecheckwouldincorrectlyproduce"INF"or

somedesignforcescouldbereportedaszero. Fixedanissuethatdidn'trememberuserenteredseismicTaforCanadiancodes. CorrectedDXFgridsimporttoincludearcs. CorrectederrorsintheChineseshapedatabaseforthefollowingshapes:TM170X250andTW150X300A. CorrectedaproblemwithreadingCIS/2filescontainingquotationmarks. FixedanissuewiththeCmcalculationforoutofplaneconcretewalldesign.Theprogramwaspreviouslyusing

avalueof0.6whenitshouldhavebeenusing1.0. FixedanissuethatcausedamajorerrorwhileusingtheOut‐of‐Plane‐Fliptoolonawallpanel. Fixedatoleranceissuewhichcouldcausetheseismicself‐weightcalculationtobeincorrectwhenmember

arealoadsareusedaspartoftheself‐weight. Correctedanissuewhereh/wratiosforwoodwallswithmultipleopeningscouldbecalculatedincorrectlyfor

theFTAOdesignmethod. CorrectedaproblemwithexportingmodelsusingRigidLinkstoDXF. Removed"Trimmer"fromwoodwallopeningdetailreports,asithadnoimpactonthedesign. FixedaunitsissuewiththeDeflectionRatiovalueonthedetailreportforoutofplaneconcretewalldesign.

Previouslythisratiowasconservativelyoffbyafactorof12.

Page 2: Release Notes 3D

ReleaseNotes

Fixedanissuewithoutofplanedesignofconcretewallswheretheinplaneaxialforce(entirewall)wasbeingusedinsteadoftheperfootaxialforce.

Correctedanissuewithlintelforcesformasonrywallswherethedesignignoresanyappliedforcesifthelinteldepthwenttothetopofthewall.

Fixedanissuethatdidn'tsavethedynamicsolutioninsideRISA‐3DfromunderRISAFloor. Fixedanissuewithoutofplaneconcretewallswheretheminimummomentwasnotbeingusedinallcases. Fixedanissuewheresomefootingswouldnotbedesignediftheallowablesoilbearingwassetto"Gross." CorrectedanerrorwhereaRISA‐3DmodelunderRISAFloorwouldnotsolveadynamicsolutionunlessthe

userhadpreviouslyusedtheSeismicLoadGenerationtogeneratenodesonthediaphragm. Correctedanerrorwhereuser‐inputseismicparameterswerebeingincorrectlyreportedontheprinted

output. CorrectedadisplaybuginwhichthegraphicaldisplaydimensionsforaGeneralArbitraryshapedidnotupdate

whentheshapepropertieswereedited. Correctedanissuewithshearanddeflectiondiagramsofsingleangleswithnodesalongthelengthofthe

physicalmember. Fixedanissuewiththeaxial,shearandmomentenvelopeddiagramsforconcretewallsintheout‐of‐plane

direction. CorrectedanerrorinwhicharealoadswerenotbeingproperlycopiedwhenusingtheMirrorCopycommand. ChangedLe/dcalculationforSCLwoodmemberstouseactualratherthannominaldimensions. CorrectedanissuewithACIthresholdtorsioncalculationswhichcausedthemnottobereportedforenvelope

solutions. UpdatedAppendbehaviortocomparetheSectionSetinformationbetweentwomodelsbeforeappending.

PreviouslyamemberdefinedasSectionSet1inonemodelwouldbecomeSectionSet1inthe2ndmodelevenifthetwoshapeswerenotthesame.

CorrectedaminorissuewithAISC13thand14theditionswhereincorporatingtorsionalshearstressesintothecodecheckwasoverlyconservative.

CorrectedanissuewhereoutdatedinformationwassenttoRISAConnectionfromRISA‐3Dand/orRISAFloorduetoinconsistencies.

Version 11.0.1 Enhancements/Corrections

RISA‐RevitLinkUpdates CompatiblewithRISA‐RevitLink2013version2 AddedBIMID'sforRISAFloorslabopenings. Fixedawallpanelissuewherechangesmadetowallswouldaffectallwallsexceptone.

RISAConnectionIntegration CorrectedcolumnconnectionorientationwhenusingtheRISAFloor/RISA‐3DtoRISAConnection

integration.Previouslytheintegrationwasalwaysproducingaconnectionframedtotheflange. RISAConnection/TeklaStructuresLinkUpdates

AddedcompatibilitytosupporttheupcomingreleaseoftheRISAConnection/TeklaStructuresLink Cold‐FormedSteelUpdates

AddedAISIprovisionB4tothecheckoftheflangesforweak‐axisbending. Addedthefullelasticcomputationforthe"Is"valuesintheAISIB4provision. FixedanerrorinthecalculationofSeyforZSshapes.

Version 11.0 Enhancements/Corrections

Enhancements

Added64‐bitversioncapability. Theprogramwillrunin64‐bitaddressingspace,expandingWindowsmemorylimits. Allowsforincreasedprogramlimitswhenrunningona64‐bitoperatingsystem.

Page 3: Release Notes 3D

ReleaseNotes

AddedtheabilitytoimportaDXFunderlay;Allowsuserstosnaptotheunderlaywhendrawingmembersandwalls.

AddedtheAF&PANDS‐12(ASD)woodcode. AddedtheACI530‐11(ASD&Strength)masonrycode.

Addedmanysupplementalvaluesandextramessagingtomasonrywalldetailreports. Addedoptionformasonrywallstodefinethewallarea(RMEHorNCMA).Priorversionsusedonlythe

ReinforcedMasonryEngineerHandbook. AddedtheAISIS100‐10(ASD&LRFD)/CSAS136‐10:LSD/CANACERO2010(ASD&LRFD)cold‐formedsteel

code. AddedtheAAADM1‐10(ASD&LRFD)aluminumcode. AddeddesignfortaperedmembersperAISCDesignGuide25. AddedtheAISC341/358‐10seismicdesignprovisions. AddedtheCSAS16‐09Canadiansteelcode.

Addedcodechecksforclass4sections. Addedcodechecksforsingleanglesforbothbendingandtension/compression. UpdatedtheCanadiansteeldatabaseperthe10theditionmanual.

AddedtheNBC2010Canadianbuildingcodeprovisions. Addedwindandseismicloadgeneration. Addedthedesignresponsespectra. Addedtheloadcombinations(serviceandstrength)totheLoadCombinationGenerator.

Reducedstart‐uptimesbyusingafastershape‐to‐databasecomparison. Updatedhold‐downdatabasesfornewerSimpsoncatalogs(perIBC2006/2009). AddedaVirtualJoistGirderdatabaseanddesignlistperSJIrecommendations. Addedtheabilitytoperformconcretememberdesignforoverstrengthloadcombinations. AddedanupperlimitondesignmomentforordinarymomentframesperAISC341commentarySection11.2a. Increasedthemaximumnumberofmodesallowedinadynamicsolutionfrom500to2,000. AddednewconnectionfeaturesforintegrationwithRISAConnection3.0.

AddedtheAISC360‐10(ASD&LRFD)codeforRISAConnectionintegration. Addedsupportforslightlynon‐concentricbraces. AddednewConnectionTypestotheConnectionRulesspreadsheet.

Corrections

Correctedanissuewhichwouldcausecolor‐codedcodecheckstodisplayallblackforconcretemembers. Correctedanissuewhichwouldcausetheprogramtoshutdownifviewingcolor‐codedcodechecks. Correctedanissuewhereseismicfactors(Rho,Omega,Sds)werenotproperlyapplyingtostructureself

weight.Thesevalueswereusingavalueof1.0tofactortheself‐weightportionoftheload. Correctedthecalculationoftheweakaxisbendingcapacityofnon‐compactandslenderchannelsdesignedto

AISC13thor14theditionsteelcodes. Correctedanissuewiththeseismicdetailingcalculationswherethehorizontalcomponentoftheunbalanced

braceforce(forChevronbraceframes)wasreportedincorrectly. Correctedanissuewherewoodwalldesignresultswerenotgivenforawallwithtworegionsstackedontopof

eachotherwithnodiaphragmpresent. Correctedanissuewherethe2b/hcalculationforslenderpiersonsegmentedwoodwallscouldbeincorrect

forversion10. Correctedanissuewheretheprogramwasincorrectlycalculatingsomecrosssectionpropertiesforthe

principalaxesofsingleangles. Correctedanissuewitharealoadattributionwhichcausedoddtransientarealoads. Correctedacalculationerrorrelatingtominimumverticalreinforcementinconcreteshearwalls. Correctedanissuewhereseismicwebcompactnesscheckcoulderroneouslyfailforbracemembers. Correctedsomeissueswithconcretecolumnoptimizationwhichcouldcauseoverlyconservativecodechecks.

Page 4: Release Notes 3D

ReleaseNotes

Correctedanissuewhereaninstallpathwithlongfile/directorynamescouldcausetheprogramtofailtolaunchwhenusingfileassociation.

Correctedissuesrelatedtomasonrywalldesignregardingunreinforcedwalls. CorrectedaproblemwithRISA‐3DclearingresultswhenusingtheDirectortooltoswitchbetweenRISAFloor

andRISA‐3D.

Version 10.0.1 Enhancements/Corrections

Enhancements

Enhancedperformanceon64‐bitoperatingsystemstoallowuseofupto4GBofmemory. Addedspacingandminimumsteelreinforcementareachecksforconcretewalls. AddedSeismicDesignRuleselectiontothememberdoubleclickdialog. Addedabilitytodoconcretememberdesignforoverstrengthloadcombinations. AddedautomaticflippingofgravityloadsanddiaphragmstotheSwitchVerticalAxistoolintheToolsmenu. AddedthecalculationofCvforshearcapacityofsingleanglesfortheAISC14thEdition. Principalaxisnotationwasaddedtothedetailreportforaluminumsingleangles. Addeddetailreportwarningsformembersandwallpanelswhentheseelementsarenotconsideredfor

overstrengthloadcombinations. Enhancedspreadsheetbehaviorsothatcolumnwidthswillberememberedwhentheyareupdated. Simplifieddatabaseshapecomparisonstoreduceprogramstart‐uptime. UpdatedtheDrawWallPanelsdialogtorememberapreviousaction. UpdatedtheprogramtoaccountforstoryshearintheSeismicDetailingPanelZonesheardemandcalculations. UpdatedsavingresultsbehaviorwhenworkinginlinkedprogramssothatclickingtheSaveResultsbutton

oncewillsavetheresultsforalllinkedprograms. UpdatedtheCopyRotatetooldefaultsettingsandupdatedtheStatusBartobetterprompttheuser. AddedvalidationtoconfirmthatallDesignRulesarevaliduponopeningamodel. ChangedmemberdetailreportstoshowAISC‐stylereportwhenAISCdesignisused.Thishappenswhen

foreigncodesareunclearonprovisions. Updatedthemodeldeflectedshapetonowincludesolidelements.Previouslywhenviewingthedeflected

shapethesolidswerenotvisible. Updatedwoodwallheaderoutputtostatewhethertheheaderiscontrolledbybendingorshear. Addedarestrictiononsingleanglessuchthat"depth"legcannotbeshorterthan"width"leg. RenamedAISINAS‐07toS100‐07basedoncodenamingconventions. Removedtheupperlimitof3.0onCbforbendingcapacityfortheAISC14thEdition. RemovedmomentmagnificationfortheACI318‐08code,asaP‐Deltaanalysisisrequired. RemovedalimitationonrebarFyontheConcretetaboftheMaterialsspreadsheetandaddedawarningfor

ACIcodeswhenrebarFyexceedsallowable. User‐definedwallpanelboundaryconditionsarenowconsistentacrossmasonry,concrete,andgeneralwall

types. MadethecalculationofthetotalseismicweightconsistentbetweentheSpectraScalingDialogandtheInsert

SeismicLoadsdialog.Bothnowcomputeanyloadbetweenthediaphragms(orbaseand1stfloordiaphragm)basedonthedistanceoftheloadtothefloororbase.

RemovedLtorquefromthebendingcapacitycalculationsforAISC13thand14theditions.Ltorquenowonlyaffectsaxialcapacitycalculations.

ChangedcolumnEulerbucklingslendernessviolationsofAISC341SeismicDetailingfromafailuretoawarning.

Updatedshearpaneloptimizationandhold‐downselectioninwoodwallstobebasedonwalldesignrule'sMaxShearCheckandMaxBendingCheckrespectively.Previouslythisvaluewasalwaystakenas1.0.

UpdatedmasonrydesignforbothASDandStrengthsothattheWallDesignRules‐MaxShearCheckcolumnworksproperly.Previouslyitwasassumedthatthemaximumshearcheckwasalways1.0.

Page 5: Release Notes 3D

ReleaseNotes

UpdatedtheM2calculationforoutofplanedesignofconcretewallssothatthereisaninteriorandexteriorvalue.Previouslythemaximumvaluewasbeingusedinbothinstances.

UpdatedthecalculationoftheM2momentforconcretewallpanelsateachsectionalongtheheightofthewall.PreviouslyitwastakingmaximumM2momentatanyplacealongtheheightofthewallandusingitforeverysection.

UpdatedChileanSteeldatabaseperAceroDiseñoEstructuralManual–SegundaEdicion

Corrections

Correctedanissuewithnetworklicensevalidationthatcouldcauseaslowdownwiththeuserinterface. Correctedanissuewherenetworkclientcomputerscouldnotfinddatabaseswhenlaunchingtheprogramin

demonstrationmode. CorrectedthebendingcapacityofdoubleanglesintheAISC14thEdition. FixedanissueintheASCE7‐10SeismicGlobalParameterswhereOmegaandRhocouldnotbeanythingother

than1.0. FixedaunitconversionissuewiththeMaterialTakeOffoutputsothatthevolumeofconcreteisonlybasedon

thedensityunit. Correctedaproblemwherewallpanelstiffnesswasincorrectlyoverestimatedwhenusingmetricunitsdueto

aunitconversionerror. Fixedaproblemwiththeloadmeshingforflexiblediaphragmsthatwouldproduceerrorcode2136. FixedtheLoadCombinationGeneratorsothatthenotionalloaddirectionwillalwaysbethesameaswindload

directionforanindividualcombination. Fixedametricunitsproblemwithmasonrylintelswherechecktomakesurethatthereinforcementfitswithin

themembergeometrywasnotworkingcorrectly. FixedtheflexiblearealoadattributioninaRISA‐3DunderRISAFloormodelsothatinactivatedmembersdo

nothaveloadattributedtothem. FixedanissuewiththecalculationofthetributaryareaofdoubleanglemembersforOpenStructurearea

loads. Correctedaloadattributionissuewitharealoadsandmetricunitsnotmatchingthesameattributionas

imperialunits,althoughtotalloadwasstillcorrect. Correctedanissuewhereconcretecolumnsintensionwouldnotdesignshearreinforcementspacinginthe

centerspanregion. Fixedthedisplayofincorrectgoverningequationnumbersforbendingcapacitiesonflataluminumplatesin

thedetailreports. CorrectedanissuewheretheWebYieldinglimitstatecouldbeoverestimatedinthecontinuityplatechecksof

theSeismicDesignresults. CorrectedanissuewherethephifactorwasnotbeingappliedforWebBucklingcalculationswithintheSeismic

Designresults. Updatedanissuewithwoodwallpaneloptimizationwherehavingmultipledesignrulescouldcausean

individualwalltobedesignedtoadifferentwalldesignrule. FixedanissuewithmasonrywallswherethestiffnesswasnotbeingresetwhenyoumakeachangeintheWall

DesignRulesspreadsheet. Fixedmulti‐storywoodwallsinRISA‐3Donlymodelssothatyouwouldgetresultsforallregions.

Version 10.0 Enhancements/Corrections

Enhancements

AddedAISC360‐10(14thEdition)ASDandLRFDcodechecksforhotrolledsteelmembers. TheAISCDatabasehasbeenupdatedtoincludenewshapesinthe14thEditionAISCManual. AddedASCE7‐10totheWind/SeismicLoadGenerationandtotheLoadCombinationGenerator. AddedACI318‐11codechecksforconcretemembers.

Page 6: Release Notes 3D

ReleaseNotes

Addeda"ThresholdTorsion"checkforconcretebeams. Addedabilitytoassignopeningsinconcretewallpanels. AddedauserdefinedtorquelengthtothedesignpropertiesforAISC360‐05(13thEdition)andtheAISC360‐

10(14thEdition). AddedCanadianParametricDesignSpectraperNBC2005totheResponseSpectraLibrary. AddedCSAS136‐04codechecksforcoldformedsteelmembers. AddedCSAS136‐07codechecksforcoldformedsteelmembers. Addedthelocationofdemandandcapacitypointsoninteractiondiagramsforconcretewalls. AddedaTools‐PreferencesoptiontoaddtheindividualLoadbuttonoptionsbacktotheDataEntryToolbar. AddedaCopyOffsettool. AddedLoadCombinationGenerationfilesfortheSaudiSBC301‐2007code. AddedtheabilitytoprintResponseSpectraandMovingLoadinputdata. AddedtensioncodechecksforAluminumsingleangles. Addedhydrostaticloadstothecirculartankgenerationutility. Addedtheabilitytoclickajointtodefinetheoriginofthecopy‐rotateormove‐rotatecommands. AddedtheabilitytofliplocalaxesofWallPanelswithoutflippingtheopeninglocations. AddedtheabilitytoprintsectionpropertiesfromtheShapeDatabasedialogs. Addedoptionalabilitytocopyheaderswithspreadsheetdata.(OptionalbasedonaTools‐Preferencesetting.) ExpandedtheTorsionalBuckling/FlexuralTorsionalBucklingcodechecksforAISC360‐05(13thEdition)and

AISC360‐10(14thEdition)toapplytoshapesotherthanWT'sandLL's. ModifiedthetreatmentofmasonryandwoodWallPanelstoautomatestiffnessupdateswithinthe

optimization/SuggestedShapesresults. ImprovedthegraphicalCopytools. ImprovedmasonryWallPaneldefinitionstobebasedonWallDesignRulessothatitwillbeeasiertochange

multiplewallsatthesametime. ImprovedreportingofOverturningMomentSafetyFactorswhenRISAFootrunsfromwithinRISA‐3D.(This

affectsLoadCombinationsbuiltwithBasicLoadCasenumbersratherthanloadCategories). Improved/reorganizedtheSolutiontabofGlobalParameterstobemoreuser‐friendlyandeasiertoread. UpdatedpropertiesintheColdFormedSteelDatabase(basedonbendradiuschanges). Improvedthecodechecksforconcretecolumnsforcaseswherethecolumnissubjectedtonettensionplus

bending. RemovedtheobsoleteTradeArbeddatabasefromtheinstallationroutines.

Corrections

CorrectedanerrorwithCanadianNBC2005SeismicLoadGenerationwheretheprogramwasusingtheSa(0.2)valueinsteadoftheS(0.2)value.

CorrectedanissuewhereshapesfromolderRISASectionfiles(version1.1andearlier)hadissueswithsheardeformation.

Correctedabugthatcausedtheweak‐axisbendingstrengthofwideflangesmemberswithslenderflangestobeoverestimatedintheAISC360‐05(13thEdition)code.

CorrectedanissuewithdistributedloadsontaperedWideFlangesteelmemberswhereaportionofthedistributedloadcouldgetignored.

CorrectedanissuewithCanadiandesignofsingleangleswherecompressioncodecheckswerereportingavalueof0.0ratherthan'NoCalc'.

Correctedanissuerelatedtoaluminumdatabasesandsingleangleflexural‐torsionalbucklingcodechecks. Correctedanissuewiththealuminumcoderelatedtotheallowablebendingstressesforrectangulartubes

subjectedtoaminoraxialforce. Correctedandissuewhereseismicdetailingslendernesslimitfailureswerereportedinthewrongcolumnof

theSeismicDesignResultsspreadsheet. CorrectedaseismicdesignresultsissuewheretheconnectiondesignmomentsforSMFframeswerebeing

conservativelyreportedatthecenterline(ratherthantheface)ofthecolumn. Correctedsomeissuesrelatedtohowoverstrengthloadcombinationswereincludedinanenvelopesolution.

Page 7: Release Notes 3D

ReleaseNotes

CorrectedanissuewhereNotionalLoadGenerationwasnotproperlyaccountingforeffectsofopeningsinwallpanels.

CorrectedanissuewiththeLoadCombinationGeneratorwheretheprogramwasproducingextra(andunnecessary)loadcombinations.

Correctedaunitsconversionissuerelatedtorebarstrengthforcustomrebarlayouts. Correctedaunitsconversionissuerelatedtothermalloadingonplateelements. CorrectedanissuewhereseveralGlobalParametersvalueswereomittedfromprintedoutputorwereprinted

incorrectly. Eliminatedlateral‐torsionalbucklingcodechecksforColdFormedHUsectionsbentabouttheiry‐yaxis. FixedaunitsconversionproblemwithRISASectionshapepropertiesusedinRISA‐3D/RISAFloor. CorrectedanissuewiththeRISA‐RevitLinkwhichcouldresultinloadsbeingdeletedduringaround‐trip. Correctedadisplayissuewhereenvelopesolutionsforcoldformedsteelwerenotproperlyshowingphiand

omegavalues. CorrectedanissuewheretheReplaceandResolvefunctionwasnotproperlyinteractingwiththegraphical

Excludefeature. Correctedanissuewiththeshearcodecheckofmulti‐spanconcretecolumnswherethecontrollingshear

locationwasalwaysassumedtobeattheendofthemember. Correctedanissuewherethe'j'valuedisplayedinamasonrywalldetailreportcouldbeerroneouslyshownas

1.0.(Thiswasadisplayissueonly;thecalculationswerecorrect.) CorrectedanissuewiththecalculationofAs_maxfortheIS456Indianconcretedesigncode. CorrectedanissuewheretheGuptamodalcombinationmethodwouldcauseawallpanelmodeltocrash

duringanResponseSpectraAnalysissolution. CorrectedanissuewithOpenStructurearealoadswhereroundmemberswerereceivingover‐conservative

loading.

Version 9.1.1 Enhancements/Corrections

AddedintegrationwithRISAConnectionforhotrolledsteelconnectiondesign. Madeanumberofenhancementsassociatedwithdatabaseshapevaluesandpresentation:

TheAISCDatabasehasbeenupdatedtoincludenewshapesinthe13thEditionAISCManual. ThesectionpropertiesofAISCshapeshavebeenupdatedtoreflectnewvaluesinthe13thEditionAISC

Manual. Wheninstallingoveranolderversion,thedatabaseofobsoleteAISCshapesisretainedasan

“AISC_Backup”shapedatabase. AISCshapesinexistingmodels,whichhavesectionpropertiesthatdifferfromcurrentdatabasevalues

bylessthanaspecifictolerance,areautomaticallyassignedthenewsectionproperties.However,ifthedifferenceinsectionpropertiesexceedsthetolerancethentheexistingsectionpropertiesareretainedwithanewshapenamewhichhasan_HRAsuffix.

Added"k"valuestohotrolledsteeldatabasestoallowforbetterintegrationwithRISAConnection DesignListsupdatedforthenewAISCshapes.Backupsofolderdesignlistsaresavedwitha*.bak

extension. EnhancedintegrationwithRISASection(version2.0)toallowforcodechecksonimportedHotRolled

Steelshapes AddedaPrintfunctiontotheEdit/ViewdialogintheShapeDatabase. EnhancedthegraphicalrenderingofGeneralandArbitraryShapestoallowforeasieridentificationof

stronandweakaxes AddedtheIS800‐2007IndianSteelcode. AddedtiedownforcesandshearforcestotheWoodWallIn‐Planeresultsspreadsheet. Updatedthecold‐formedsteeldatabasestobefullyeditable. Improvedtheprocessingtimeforthecreationofresultsbrowsersorflatfileprinting. Improvedthe"ModelMerge"utilitysothatthetrim/extendwallpanelsoptionwillalsocorrectfornon‐

coplanarwalls. Improvedtheinteractiondiagramsforconcretewallpanelstomakethemmorecontinuous.

Page 8: Release Notes 3D

ReleaseNotes

Addedanupperlimittothelip/widthratioforcoldformedsteellippedchannelsectionsinordertoproperlycalculatek(theplatebucklingcoefficient).

Addedawarninglogmessageformasonrywallsthatuseuncommonmaterialstrengthswithuncommonblocksizes.Self‐weightwillnotbeaccountedforthesewallsandmustbeappliedmanually.

AddedagraphicalRe‐Labelingoptionssothatuserscanselectivelyre‐labelexistingitemsbasedonthecurrentselectionstate.Thisalsoallowsusertoapplyadifferentprefixtoselecteditems.

TheEuroCodeforHotRolledSteel(1993‐1‐1)nowusestheAISCCbformulatocalculatetheC1coefficientforbeamlateral‐torsionalbuckling.thisvariablewillbeoverriddenwhentheuserentersavalueinthedesigndataforthemember.

Fixedanissuewithseismicdetailingcheckssothatthe"framesintocolumnstrongaxis"checkwillnowonlybeperformedforbeamswithfullyfixedends.

Fixedanissuewhererunningaloadcombinationwithamovingloadinamodelwithconcretewallswouldcauseanerror.

CorrectedanissueregardingmemberforcescalculatedfromaResponseSpectraAnalysiswhenusingtheDirectAnalysisMethodwhichcouldresultinun‐conservativevaluesformembermomentsandcodechecks.

Fixedaproblemthatcausedanoverstrengtherrormessageandnoresultstobedisplayedwhenamovingloadwassolved.

Correctedanissuewithcalculationofseismicandnotionalloadswheretheselfweightofwallswasnotbeingproperlyattributedtointermediatediaphragmlevels.IssueexistedonlyforRISA‐3DmodelsthatwerenotlinkedtoRISAFloor.

CorrectedanissuewhereRSAloadcombinationswerenotproperlytriggeringtheAISCSeismicdetailingcalculations.

CorrectedanissuewhereapplyingseismicdetailingtoHbracememberscausedaresultsbrowsererror. CorrectedanissuewheretheSeismicDetailingResultswouldnotdisplayproperlyformembersdefinedwith

thefunctionsetto"gravityonly". CorrectedthecalculationofeffectivesectionmodulusforMnyinHUcold‐formedshapes. Correctedanissuewherepointmomentscouldbelostifappliedatthesameendofamemberasapinned

momentrelease. Correctedaproblemwithwallsurfaceloadsthattouchedopeningedges,whichcausedresultstobereported

asinfinity. Fixedmiscellaneouserrorswithdetailreportsforconcretebeamswhencustomshearrebarlayoutswereused FixedanissuewhereconcretewallswouldnotbedesignedifZistheverticalaxis. Fixedanissuewithwoodwallswheretheheaderoptionfor"SameasOpening"wasnotusingthesame

materialfromthecopiedheader. FixedanerrorwhichcouldcausetheCustomWoodSpeciescountertobeoff,preventingthemodelfrom

opening. UpdatedtheHDUwoodhold‐downdatabasestocorrecttheHDU145‐1/2"&7‐1/4"capacityvalues.The

updatewilloverwritetheoldfileandbackitup. FixedaUnitsissuewiththechordcapacityforwoodshearwalls Fixedaproblemthatcausedwallchordtensiontobereportedwhentherewasnone.

Version 9.1 Enhancements/Corrections

Enhancements

AddedConcreteWallPanelsperACI318‐05andACI318‐08specifications: Abilitytodesignreinforcement(bothshearandaxial/bending). Abilitytodesignreinforcementforoutofplanewallloading(axialbendingandshear) Providesstorydeflectionsforeachstoryinamulti‐storywall.

AddedSeismicDetailingcodechecksperAISC2005: MomentFramedesignperAISC358(RBS,BFP,BUEEP,BSEEP,WUF‐W) StrongColumn/WeakBeamcalculations

Page 9: Release Notes 3D

ReleaseNotes

Columnchecksforconnectionforces(i.e.continuityplatestiffeners) Calculationofrequiredstrengthandstiffnessofbeambracing PanelZonecolumnchecks ConcentricallyBracedFramesperAISC341 CalculationofunbalancedforcesforVandinvertedVbraces.

SingleAngles: Addedabilitytodesignatethataxialcodechecksshouldbebasedongeometricorprincipalaxis

buckling.SeetheHelpFileSingleAnglesub‐topicofMemberResultsformoreinformation. Addedbendingcodechecksforsingleanglemembersbasedonbendingaboutgeometricorprincipal

axes.SeetheHelpFileSingleAnglesub‐topicofMemberResultsformoreinformation. MadechangestotheMasonryandConcreteMaterialsspreadsheets:

Movedthedefinitionoftheyieldstrengthofthereinforcement(Fy)fromtheDesignRulesspreadsheettotheconcreteandmasonrytabsofthematerialsspreadsheet.

MovedthemasonryselfweightdefinitionfromtheDesignRulesspreadsheettotheMaterialsspreadsheet.

ThiscouldresultinreducedbackwardscompatibilityofConcreteandMasonryMaterialswitholderversionsoftheprogram.

AddedanumberofimprovementsfortheColdFormedSteelcodechecks AISI2004ColdFormedSteelcode AISI2007ColdFormedSteelcode AddedMexican(Canacero)2004and2007codes UpdatedtheAISIandSSMAdatabaseshapepropertiestoreflectthenew2007codeprovisions. AddedOmegaandPhifactorstocoldformedsteeldetailreportsandspreadsheets.

AddedAF&PANDS‐08:ASDWoodcode. AddedACI530‐08Masonrycode. AddedACI318‐08Concretecode. Addedbackintheabilityoftheprogramtolaunchin"DemoMode"whenalicenseisnotdetected.Featurenow

requiresthecreationofaDemosub‐folder. Addedatooltoflipthelocalaxesofexistingwallpanels. ModifiedtheCLcalculationsforglu‐lamswithd/w<2.0. AddedtheabilitytographicallydisplaywallpanelDesignRules. AddedtheCbcalculationforcoldformedsteelmembers. SimplifiedtheinterfacebysplittingtheDesignRulesspreadsheetintoaWallDesignRulesandaseparate

MemberDesignRulesspreadsheet.Thiscouldresultinreducedbackwardscompatibilityofdesignruleswitholderversionsoftheprogram.

SimplifiedtheDataEntryToolbarbarmovingtheaccessoftheindividualloadspreadsheetstobewithintheBasicLoadCasesspreadsheet.

AddedP‐Deltacalculationsforwallpanels. Removedinternalwallpaneljointsfromtheprogramlimitformaximumnumberofjoints. Improvedthegraphicdisplayofslopeddistributedloadstobemorelegible. ImprovedthetreatmentofwoodwallscheduleswhenusingtheAppendfeature. Improvedwoodwallholddownreportinginthedetailreportforcaseswheretheallowableholddownforce

wasadjustedforloaddurationfactororsuch. AddedaNote/Warningtothedetailreporttoalerttheuserwhenaholddownrequiresachordsizegreater

thanthatspecifiedfortheexistingwoodwall. ChangedthestiffnessusedfordynamicanalysistoignoretheDirectAnalysismethodstiffnessreductions. ChangedtheModifyMemberPropertiesdialogtoallowforindependentadjustmentofmembertypes,material,

anddesignlist. ChangedtheModifyMemberDesigndialogtobemoreuser‐friendlybyintroducinggroupboxesandre‐

organizingexistingdata. ImprovedthecodechecksforperforatedwoodshearwallsbyaddingacheckforNDSSDPWSsection4.3.5.3

(maximumunitshearcapacity).Thisonlyaffectswallspanelwith+1370plfshearcapacity. RemovedtheKL/rlimitationcheckformembersthataremarkedas"tensiononly."

Page 10: Release Notes 3D

ReleaseNotes

UpdatedtheASCE7‐05minimumbaseshearcalculationtoaccountforSupplement#2(0.044*I*Sds>0.01). AddedtheabilitytoappendR3DorRT3filesintoanexistingRT3file. ImprovedtheshearcodecheckreportingformasonrywallswithashearstressgreaterthanFvm.Previous

resultswereaccurate,butcouldbemisleadingaboutthelocationofthegoverningcodecheck.

Corrections

CorrectedanissuewiththeTeebeamflangewidthcalculationsfortheCanadianConcretecode.Previously,slabthickness(conservatively)andspanlength(non‐conservatively)limitswerebasedontheACIcode.

CorrectedanissuewiththeChineseshapedatabasewherethex‐barvaluesforchannelswereincorrectandwerepreventingcodechecksfrombeingcalculated.

CorrectedanissuewiththeEuroSteelcodechecksforclass4(slender)sectionswhichcouldresultinoverconservativecodechecks.

CorrectedanissuewhereFloormodelswithflexiblediaphragmswouldnotproperlysolveanenvelopesolutionwhichcontainedmovingloads.

CorrectedanissuewiththeaxialcodecheckofaluminumtubesandRectangularmemberswheretheallowableaxialstresswasincorrectlybeingmultipliedbythememberarea.

Correctedatoleranceissuewiththecodecheckingofconcretecolumns.TheprogramwasunnecessarilyswitchingfromExactIntegrationMethodtoPCALoadContourmethodforcaseswherethemomentswereveryclosetozero.

CorrectedatypointhewoodpanelholddowndatabaseforHDU14‐5.5holddowns. Correctedanissuewherealuminummemberswouldnotdisplayforceandstressvalueswhentheirdesign

codewassettonone. CorrectedanissuewiththeCmcalculationforENV2005. Correctedanissuewhere"taperedmembers"whichdonothaveanytaperweregettingincorrectcodechecks. CorrectedanissuewiththeAustralianandNewZealandsteelcodecheckwherememberswithonlyaxialforce

couldgiveacodecheckofzero. Correctedanissuewithaluminumcodecheckswhentheallowabletensionforcecontrolstheallowable

bendingforce.Previously,thegoverningequationswerenotbeingreportedcorrectly. CorrectedanissuewheretheprogramwastransposingtheSXandSZspectrascalingfactorsintheload

combinations. Correctedanissuewhereseismicredundancyfactor(rho)wasbeingtakenaszeroifitwasincludedwithloads

appliedtoaflexiblediaphragmthatcameoverfromRISAFloor. CorrectedanissuewiththeASandNTCconcretecodeswherethereductionfactors(phi)werenotdisplaying

properlyonthecolumninteractiondiagrams. Correctedanissuewhichcaused1992Eurocodeequationnumberstobemistakenlyreferencedwhenthe

2005EuroSteelcodewasused.Codecheckswerecorrect;onlythedisplayedequationnumberswerewrong. Correctedaproblemwhichcouldcausefilecorruptionsassociatedwithwoodmaterialcounters. CorrectedatoleranceissuewiththeBS5950SteelcodewhichcouldcausetheTable9stressadjustmentstobe

ignoredformemberswithathicknessofupto2.5mmgreaterthanwhatwouldnormallyrequirereduction. CorrectedanissuewithlintelsformasonrywallpanelswheretheMnwasbeingcalculatedasanegativevalue. CorrectedanissuewhichcouldcauseacrashwhenopeninganRT3(RISATower)filewithsavedresults. CorrectedanissuewhichcouldcausemodelswithwallpanelstocrashwhenexportingtoDXF. Correctedanumberofissueswithloadattributionforslopedfloors. Correctedanissuewithwoodshearwallswhereputtingtheassumedtensionchordincompression(orthe

assumedcompressionchordintension)couldresultinanincorrectlyreportedchordforce.Thesecasesnolongeraffectthechordforcereporting.

Correctedanissuewiththeconcretecolumnrebardiagramswhichcouldcausethedetailreporttocrash. CorrectedadisplayissueinthedetailreportforGeneralwallpanelswherethelengthofthewallcouldbe

reportedincorrectly. Correctedatoleranceissuewithprojectedarealoadswhereaprojectedloadwhichwasnearlyparalleltothe

planeofthearealoadcouldresultin‐1.#INDmemberresults.

Page 11: Release Notes 3D

ReleaseNotes

Version 9.0.1 Enhancements/Corrections

Enhancements

Addeddrawingofflexuralreinforcementinthecolumncrosssectiontoconcretecolumndetailreports. Addedanoptiontouseanon‐iterative(Tau=1.0)methodfortheAISC360/13theditionDirectAnalysis

method. ModifiedtheAISCdirectanalysismethodtoignoretheswayflags.SeetheLimitations‐StiffnessAdjustment

sectionofthehelpfileformoreinformation. Improvedthewallmeshroutinesinteractionwithmemberarealoads.SeeAreaLoadDistributioninthehelp

fileformoreinformationontheinteractionbetweenwallsandarealoads. Improvedtheplottingofthedeflectedshapeformemberswithshearandaxialreleases. ModifiedtheConcreteColumndetailreportssothattheyalwaysshowtheinteractiondiagramregardlessof

whatloadingisappliedtothem. Improvedthecustomrebarlayoutdialogtobeeasiertouse.

Corrections

CorrectedanissuewheretherhoandOmegafactorsusedintheLoadCombinationsspreadsheetwerealwayssetto1.0regardlesswhatparameterswereenteredintheSeismictaboftheGlobalParameters.

Correctedanissuethatcausedoverconservativecalculationsofallowableflexuralstressesforaluminumroundtubesandchannels.

Correctedanaluminumdesignissuewhichresultedinincorrectslendernessparameters(S1andS2)beingusedfortubeshapes.

Correctedanissuewiththeexpandedforcediagramsforconcretemembers. Correctedanissuewhereaninactivediaphragm(combinedwithauto‐generatedseismicloads)couldcausea

filecorruptionandpreventthemodelfromopeninginversion9.0. CorrectedanissuewhereinformationchangedintheFootingstabofGlobalParameterswouldnotbe

rememberedwhenclosingoutofthedialog. CorrectedanissueassociatedwithP‐DeltaanalysisintheAISC13thedition(ASDonly)formemberssubjected

tothermalloads.The1.6amplificationfactoronP‐Deltaeffectswasnotbeingtakenintoaccountforthethermalloads.

ChangedamisleadingWarningLogMessagetobemoredescriptive.Insteadof"Notenoughsolutiondata",themessagewillnowinformtheuserthattheirresultsweregeneratedbyanolderversionoftheprogram.

Correctedabugwheresomeunstableplatemodelsfailedtogeneratethewarninglogmessageaboutreactionsnotequalingthesumofappliedforces.

UpdatednotationfordesigncoefficientsforEuroCode.Previously,theEC32004codewasmistakenlyusingthenamingconventionfromthe1992versionofthecode.

Correctedanissuewhereappendingamodelcouldcausethewallmaterialtobereadincorrectly. Correctedanissuewiththewooddatabaseforthe"WesternCedar"species. Correctedanissuewheretheprogramwasrefusingtodoacodecheck(becausefb>FbE)eventhoughthe

memberwasintension. Correctedanissuewiththedisplayedunitsforwindloadgeneration. Correctedanissuewhererigidendoffsetsandcustomrebarlayoutscouldresultinanoverlyconservative

shearcheck. Fixedaunitsconversionissuewherecodechecksforwoodwallpanelscouldbeoverlyconservative. Fixedanissuewherehard‐codedwoodwallpanelswouldalwaysgiveaseismicloadcombinationasthe

governingloadcombination,evenifanon‐seismicloadcombinationcontrolled. CorrectedadisplayissuewherethememberdetailreportdisplayedadifferentFvvaluethanwasactuallyused

intheF'vcalculationforGlulammembers.

Page 12: Release Notes 3D

ReleaseNotes

Version 9.0 Enhancements/Corrections

Enhancements

AddedAluminummemberdesign Addedallshapesinthe2005AluminumDesignManual. AddedcodecheckspertheAAADM1‐05ASDforbothbuildingsandbridges.

EnhancedSeismiccapabilitieswithintheprogram: AddedaSeismictabtotheGlobalParameterstopermanentlystoreseismiccodeinformation. Addedredundancyfactor(rho)totheLoadCombinationGenerator Addedverticalseismicforce(Ev)totheLoadCombinationGenerator AddedautomaticlinkingbetweenparametricdesignspectraandtheseismictabofGlobalParameters AddedautomatedI/RscalingtotheResponseSpectraScalingdialog. AutomatedtheNon‐Orthogonalearthquakeloadoptions(100%+30%)withintheLoadCombination

Generator EnhancedloadingforslopingroofmodelsthataretransferredfromRISAFloor.

Enabledflexiblediaphragmloadattribution(windandseismic)forslopedroofs. AddedtheabilityfortheWindLoadGeneratortoincludeperpendicularslopedroofwindloadsper

Figure6‐6ofASCE‐7. Addedwindloadcalculationsforwallsandwallareasthatextendabovethebaseroofelevation.These

werepreviouslyignored. GravityloadsarenowbroughtintoRISA‐3Datthetopsofslopedwalls.Theywerepreviouslyappliedat

thebasefloorlevelelevation. AddedslopedroofwindloadcategoryoptiontotheLoadCombinationgenerator.

AddednotionalloadstotheLoadCombinationGeneratorperAISCrequirements. UpdatedthenamesassignedtoalldesigncodeoptionstomatchANSInamingconvention. Addedtheabilitytoselectivelyincludeorexcluderoofloadoptions(RL,RLL,SL)fromtheLoadCombination

Generator. Addedtheabilitytoapplymemberarealoadsperpendiculartotheplaneoftheload. Addedtheabilitytoapplydistributedandpointloadsorientedalongwallpanellocalaxes. Improvedloadattributionformemberarealoadstobemoreaccuratefornon‐uniformloads. Enhancedwoodshearwallstousethecontrollingshearpaneldesignforcodechecksofeveryregion. Improvedthedesignofheadersandstudswithinwallpanelssothatonlygravityloadcombinationsare

considered. Reducedinputfilesizebyeliminatingnailingschedulesandholddownschedulesfromallbutexplicitlydefined

woodwallsanddiaphragms. Addedthemulti‐plywoodcolumndesignadjustmentfactorperNDS15.3.2. RISA‐3Dnolongerincludesinternalwallpaneljointswhencheckingagainsttheprogramlimitsformaximum

numberofjoints. Addednetworkfilesecuritytopreventmultipleusersfromopening/editingthesamefileatonce. Reducedthememoryusageassociatedwithenveloperesultsforwallpanels. AddedaTools‐PreferencesoptiontoturnofftheSumofReactionscheck. AddedanewutilitytotheToolsmenutoassistwithaligningstackedwallpanels. AddedequationC‐F9‐1fromsteelcodecommentary(AISC360)toaccountforthebendingcapacityofafully

bracedWTwithstemsincompression

Corrections

CorrectedadisplayissuewiththeCanadiansteelcodewheretheKL/rshowninthedetailreportwasbasedontheuserenteredKvalueratherthanthevalueof1.0requiredbytheclausewhichgovernedthecodecheck.

CorrectedadatabaseissuewheresomeHSSroundmembershadanincorrectwallthicknesslisted. CorrectedtheallowableshearstresscalculationsfortheIndianSteelCodepersection6.4.2

Page 13: Release Notes 3D

ReleaseNotes

CorrectedanissuewheretheCbbehaviorwasnotproperlytiedtoauserenteredLcomp‐botvalue. Correctedaunit'sconversionissuewithinthebarstraincalculationforconcrete.ThiscouldcauseACIcode

checks(whenusingtheexactintegrationmethod)touseanincorrectphivalue,especiallyforcolumnssubjectedtobiaxialbending.

CorrectedanissuewheretheCbvaluewasbeingover‐conservativelytakenas1.0forcaseswheretheuserdefinedboththeLcompandtheCb.Thiswasoverlyconservative.

CorrectedanissuewhereCanadiancodecheckswerenotbeingperformedonsingleanglesdesignatedasEulerbucklingmembers.

Correctedaminorunitsdisplayissueforwoodwallshearcapacity. Correctedaproblemwhichcouldcauseacrashwhensolvinganyloadcombination#1000orhigher. Correctedissueswhereprogramcoulderroneouslyreportthatinputforcesdidnotequalthesumofreactions. CorrectedanissuewhereRISA‐3DcouldwriteoutaRISA‐3DfilewithanerroneousRISA‐2Dfileextension. CorrectedanissuewiththeRevitLinkwhereRISAFoundationdataembeddedinaRISA‐3Dmodelcouldget

strippedoutofthemodelafterroundtrippingtoRevit. Correctedaproblemwhereheader/linteldesignabovewoodormasonrywallopeningswasbeingskippedfor

headers/lintelsclosetothetopofawall. CorrectedanissuewheretheRISAFloorgroutspacingwasnotcorrectlybroughtintoRISA‐3D.Requiredare‐

solvetogettheMasonrywallcodecheckcorrect. Formasonrybendingthenominalwallthickness(insteadoftheactualwallthickness)isnowusedper

provision2.3.3.3bofACI‐530. Correctedanissuewithmasonryshearwallswherethelocationofthegoverningcodecheckwasreported

incorrectly. Correctedanissuewheretheuseofdesignlistswithtaperedmemberscouldcausethecodecheckfortapered

memberstobebasedonanincorrectgammavalue.Thiscouldalsoresultinanincorrecterrormessage. Correctedaproblemwithbatchsolutionsforwoodwallsthatcausedanon‐controllingchordforcetobe

reportedascontrolling. Correctedanissuewithmasonryshearwallswhichcouldcausethemomentcapacitytobereportedaszero. Correctedanissueinwallpanelforcesthatcausedrandomsignreversalofinternalwallforces. Correctedanissuewithtaperedmemberswhichcouldcausethemtoignorememberpointloadsappliedat

100%ofthememberlength. Correctedanissuewheresomereportprintingsectionswereprintingoutthewrongsections. CorrectedanissueintheRISA‐3Dflexiblediaphragmsdetailreportwheretherequiredcapacityforwindload

caseswasbeingincreasedby40%formodelstransferredfromRISAFloor. Modifiedthewindloadcalculationstousethemeanroofheightforslopedroofsratherthanthebaseroof

elevationformodelscomingoverfromRISAFloor. Correctedanissuewithexplicitlyassigneddiaphragmswhereafailedcodecheckwouldresultinawarning

messagestatingthatasatisfactorypanelcouldnotbefoundinthepanelgroupformodelstransferredfromRISAFloor.

CorrectedanissuewiththeRevitLinkwhereRISAFoundationdataembeddedinaRISA‐3DmodelcouldgetstrippedoutofthemodelafterroundtrippingtoRevit.

CorrectedaEurocodeissuewheretheprogramcalculatedazeromomentcapacityforonedirectionofatubeshape.

Correctedanissuewhereduplicate/overlappingmemberscouldcausetheprogramtofreezeduringsolution. Correctedanissuewiththeappendcommandwherematerialswithnon‐uniquelabelscouldcausethewrong

materialtobeassignedtomembersfromtheappendedmodel.

Version 8.1.3 Wood Wall and Diaphragm Enhancements

Automatedthe40%stressincreaseforwindloadcombinations(comparedtoseismic)forwoodshearwallsanddiaphragms.

AddedacheckboxforGreenLumberpertheNDSfootnotewhichreduceswallstiffnesswhenthewallhasahighmoisturecontent.

Page 14: Release Notes 3D

ReleaseNotes

Improvedthe2b/hshearstrengthreductionfactorsothatitwillnotaffectcombinationsthatincludewindload.

Improvedthe2b/hshearstrengthreductionfactorforsegmentedwallssothateachregionofthewallreceivesitsownadjustmentfactorratherthanusingtheworstcaseforallregions.

Modifiedthechordforceandstrapforcecalculationstomorecloselymatchtypicaldesignpractice.SeeWoodWall‐Designformoredetails.

Improvedtheloadattributionforverticalloadsappliedtothe"ineffective"sectionsofasegmentedshearwall. Improvedrigiddiaphragmbehaviortobettererrorcheckandcorrectformodelswhichhaveduplicatenodes

ornearzerolengthmembers. Addedcodetopreventinstabilitiesinslenderwalls.Slenderregionswillstillbeineffectiveforshearforce,but

shouldnotresultininstabilities. Improvedreportingandwarningmessagesforstraps. ChangeddefaultboundaryconditionsforwoodwallssothatFEMstiffnesswouldmorecloselymatchtheNDS

threetermstiffnessequation. ImprovedreportingforsituationswherenopanelscouldbefoundwithinthelimitsspecifiedinDesignRules. Changedthenomenclatureforthediaphragmnailingschedules.Theterm"_OT"wasreplacedwith"_RS".Both

termswerealwaysintendedtomean"OtherRatedSheathing".

Version 8.1.3 Other Wall Panel Enhancements

Enhancedthegraphicdisplayofwallpanelreactionstocoincidewithwallselectstates. Continuousboundaryconditionsarenowstoredseparatelyforwoodandmasonrywalls.Ensuresthat

switchingbackandforthbetweenmaterialswillnotpermanentlychangethewalldata. Addedawarningloganddetailreportmessagetoclarifythattheprogramdoesnotdesignmasonrywallsfor

nettension. Addedamoresophisticated'j'calculationformasonrywalls.Previousversionhadautomaticallyassumeda

valueof0.9. Improvedthetrim‐extendportionofmodelmergetodealmoreeffectivelywithwallpanels.

Version 8.1.3 General Enhancements

AddedautomaticNotionalLoadgenerationutilitysimilartotheexistingwindandseismicloadgeneration. Addedthe2007editionoftheSaudiconcretecode(SBC304). Addedstiffnessadjustmentfactor(tau_b)todetailreportsforAISC13thedition. AddedBendingSpanresultstocolumndetailreportsformemberswithcustomrebarlayouts Modifiedprogramtobemorecompatibleforfuturelinktothe2011releaseofRevitStructure. Modifiedcustomtoolbarregistrysettingstoallowuserswhoarenotadministratorstocustomizetheir

toolbars. Removedoptionforcreatingnewmodelswiththe"consistent"unitsoption. Modifiedthelegendrangeforwireframeplatecontourstomorecloselymatchtherangeshownforcolorcoded

contours. Addedanautomaticcheckfor"ghostreactions."Anytimetheappliedlateralforcesarenotequaltothe

calculatedlateralreactionsthenawarningmessagewillappeartoalerttheuser. Modifiedconcretesheartiedesigntoroundtothenearest10mmwhenmetricunitsarebeingused. ModifiedRISA‐3D/RISAFlooroptimizationroutineformembersexplicitlydefinedbytheuser. Implementedclause13.8.2boftheCanadianSteelCode(S16‐05)whichcanprovidelowercodechecksfor

specialcasesofuniaxialbending Improvedtheautoupdatedetectionsequencesothatitcannotfalselyreportthepresenceofanupdate. UpdatedSentinellibrariestobettersupportWindows7.RequiresanupdatetoSentinelSuperProdriver7.5.0

orhigher.

Page 15: Release Notes 3D

ReleaseNotes

Version 8.1.3 Corrections

Updatedthecriteriaformasonrylintelreinforcementspacingchecks.Previouslysomebararrangementswouldgiveafalsewarningmessageaboutthespacing.

CorrectedthecalculationoftheBetacoefficientforCanadianSteelCodebendingcheck. AdjustedtheaxialcapacitycalculationfordoubleanglesandWT'susingAISC13thEditiontoexplicitlyassume

CwequalszeropertheUserNote/codecommentary. Addeda3.0upperlimittotheCbcalculationforAISC13thEdition.PreviousversionsoftheLRFDcodedidnot

includethislimit. Correctedanissuewhereadynamicsolutioncoulderroneouslysolvewithtensiononlymembersspecified.

Issuewasassociatedwithreadingindatafromsavedresultsthatmaynothavebeenconsistentwiththedatafile.

Correctedanissuewiththeplatecontourplottingformodelswithappliedplatethermalloads. CorrectedanissuewherehavingthedefaultplotoptionssettodisplayaspecificLoadCombinationnumber

wouldcauseproblemswhenviewingloadsinmodelswithfewerLoadCombinations. CorrectedanissuewhererunningaKfactorauto‐calcfromaspreadsheetwithnomembersdefinedwould

causeacrash. Correctedaproblemwiththeunitsconversionofwallpanelreactions. CorrectedanissuewherethespacingofsheartieswasnotproperlytakingintoaccounttheGlobalParameter

settingforincrements. Correctedanissuewherewoodwallswithoutopeningswerenotgettingtheircapacityadjustedbasedonthe

2b/hratioforseismicloads. Correctedanissuewheretheprogramwasnotproperlyreadinginexplicitlysetwallpanelschedules. CorrectedanissuewheretheprogramwasnotfullyaccountingforadifferenceintheCD(loaddurationfactor)

usedintheholddowndatabaseversustheoneusedintheloadcombination. Correctedissuewhereheaderdesignwasreportedforthewallmaterialevenifadifferentmaterialwas

specifiedfortheheader. Correctedissuewherestrapforcesforbatchandsinglesolutionswerenotconsistent. Correctedanissuewherewallpanelresultswouldnotberememberedwhenopeningasavedsolution. Correctedanissuewhere2001NDSstressvalueswereusedforwhendoingcodechecksforGlu‐Lambeams

per91/97NDS. Correctedaunitsconversionissuewiththeselfweightofwoodwallpanels. Correctedanissuewheretheselfweightofmasonrylintelswasbeingappliedover‐conservativelyforbatch

solutions. CorrectedanissuewheretheselfweightofwallswasnotincludedintheweightusedintheautomaticSeismic

loadgeneration. Correctedanissuewherethewallmeshingroutinecouldcomeupwithadifferentmeshforstaticanddynamic

solutions. Correctedanissuewithdistributedwallloadswherechangingtheheightofthewallcouldmovethelocationof

theappliedload. CorrectedaunitsconversionissuewiththeCanadianSeismicForcegenerationforbracedframes. CorrectedissueswithPhi*MnMasonrystrengthcalculationswhichcouldresultinresultsbeingreportedinthe

wrongunitsorwithanegativevalue. Correctedanissueassociatedwithopeningamodelthathadsaveddynamicresultsforwallpanels. Correctedanissuewheretorsionalwarpingnormalstresseswerenotbeingaccountedforinthecodechecks

formemberswithnoweakaxisbendingmoment. CorrectedanissuewiththeenvelopedisplayofwallpanelreactionsintheJointReactionsspreadsheet.This

couldresultinsomejointreactionsbeingreplacedwithaduplicatecopyofawallpanelreaction. Correctedanissuewherewallpanelsurfaceloadsappliedwithtotalheightexactlyequaltothemeshspacing

wouldbeexcludedfromtheanalysis. CorrectedanissuewhereWallPanelreactionswouldbeerroneouslyremovedfromtheJointReactions

spreadsheetwhenagraphicalexcludewasperformed.

Page 16: Release Notes 3D

ReleaseNotes

Version 8.1.2 Enhancements

EnhancedthePerforatedwallpaneldetailreporttomoreclearlyshowshearcapacityconsidering2w/hreduction.

Added1%loadingmethodforseismicloadingforstructuresassignedtoSeismicDesignCategoryA. ImproveddisplayedFvandFv’valuesforGlu‐Lambeamstobetterdistinguishbetweenstrongandweakaxes. ImprovedthereportingofconcretecolumnresultsdesignedbythePCALoadContourMethod. Changedthetorsiontoleranceto20%forHSScombinedstresschecksforLRFD2ndeditiontomatch13th

editionspecification.Previoustoleranceof10%wasusedonlybecauseofalackofcodeguidance. Changeddisplayofcontinuouslyfreeboundaryconditionsforwallpanelstoimproveclarity. Addedtheabilitytoputasketchnumber(andprefix)withgraphicprinting. AddedtheabilitytospecifyPlaneStressplateswhenusingRISA‐3DunderRISAFloor. AddedRSAmethodanddampingratiototheinputfile.Previouslythisinformationdidnotgetstoredwiththe

file. CorrectedthetoleranceforreportingtheKL/rlimitforcompressionmember.Limitnowenforcedfor

compressionmemberswherecompressiondemandis1%orgreaterofthecompressioncapacity.PrevioustolerancecouldresultinmemberswithhighKL/rratiosfailingtoreporttheKL/r>200message.

AddedabilitytouseDesignResultsspreadsheetstoselectorunselectmembersinanenvelopesolution.

Version 8.1.2 Miscellaneous Corrections

Correctedautomaticout‐to‐outdepthadjustmentsfornon‐symmetricchordsgeneratedusingtheTrussGenerator.

AddedawarningmessagetotheEuroSteeldetailreportwhichreportsaflawintheEurospecwhichcreatesmomentcapacitiesequaltozerowheneverrhoapproaches1.0.

Correctedanissuewheretaperedmemberswithmultiplepartiallengthdistributedloadscouldeliminatethe2ndloadiftheloadtransitionoccurredatanintermediatejoint.

Correctedanissuewhichcouldcausetheundo/redocountertogetofftrackresultinginaninabilitytoredochangesthatweremade.

CorrectedanissuewiththereadingofthePlotOptionsdefaultfilewhichcouldcauseinterfaceissuesand/orincorrectlytriggererrormessages.

CorrectedtheIzzvalueforthe358TSB18shapeintheDietrichdatabase. Correctedaunit'sconversionissueassociatedwiththeembeddedRISAFootresults.Noissueoccurredif

modelwasre‐solvedaftertheunit'sconversion. Correctedaunit'sconversionissuewithmemberdistributedtorqueloads. CorrectedacoupleofissueswiththecalculationofNBCSeismicLoads.

Version 8.1.2 Wood Design Changes

AddedSelect/UnselectfunctionalityinRISA‐3DfordiaphragmregionsthatcamefromRISAFloor. Modifieddiaphragmdeflectioncalculationfordiaphragmsespeciallyfordiaphragmswithmultiplenailing

zones.OnlyaffectsdiaphragmsthatcamefromRISAFloor. Changedanumberofmiscellaneousthingsinthedesignofwoodshearwalls:

o ChangedenvelopingofStrapforceso Changedenvelopingofstudsandchordstobebasedonmaximumcodechecksratherthanmaximum

forces.o Applicationof2w/hadjustmentfactorsforshearcapacity.o ControllingshearforceforFTAOwallswithmultipleopenings.o Re‐definedthe2w/hadjustmentfactorforFTAOwallstoapplytotheheightoftheopening.o Addedthe2w/hadjustmentfactortosegmentedwalls.o Changedthewalltowallconnectivityofstackedsegmentedwalls.ThisresultsinFEMdeflectionresults

thatareclosertohandcalculations.

Page 17: Release Notes 3D

ReleaseNotes

o Changeddefaultboundaryconditionofwoodshearwallstobecontinuouslypinned.ThisresultsinFEMdeflectionresultsthatareclosertohandcalculations.

o Removedtheupperboundof1.0ontheSSRF(ShearStiffnessReductionFactor)toallowforthistoINCREASEthestiffnessofthewall

o Correctedvariousissueswithunitsconversiono Abilitytoreadsavedresults.o ElasticdeflectioncalculationsforperforatedwallswereapplyingtheCofactortwice.

Version 8.1.1 Enhancements / Corrections

AddedtheupperandlowerboundlimitationsforthediaphragmdesignforcesperASCE7‐05section12.10.1.1. Addedtheabilitytoattachwoodwallpanelstoabeamorcolumnviaastrap. Enhancedthediaphragmnailingoptimizationtopickmoreappropriatenailingselections. AddedtheabilitytosearchformembersbytheirMemberFunctionintheCriteriaSelectdialog. EnhancedtheerrorcheckingsothattheP‐Deltaonlyappliestohot‐rolledsteelmodels. EnhancedtheseismicforcecalculationstolessconservativelyaccountforSeismicDesignCategoryA(per

ASCE‐72005section11.7). Improvedthegraphicaldisplayofholddownsandstrapsinthewallpaneleditor. Addedoptiontographicallydeletewallstrapsandholddownsforwoodshearwalls. Addedundo/redofunctionalitytoholddownandstrapcreation/modification. Enhancedtheerror/warningreportingfornodesthatarecompletelyunconnected.Previouslythesewere

gettinglockedwithoutanyusernotification,eveniftherewasajointloadappliedtothem. EnhancedtheWindLoadGenerationutilitytobetterdetectinvaliddata(buildingheightislessthanorequalto

zero). AddedawarningmessagetothedetailreportanddesignresultsforEurocodesteeldesignwhenashearfailure

causesthecombinedstresscodecheckstobecomeinfinite(i.e.rhoisgreaterthan1.0). Correctedanissuewhere,whenrunninganenvelopesolutionwiththegraphicaldisplayofcodechecksbased

oncolor,novalueswoulddisplay. Correctedawallpanelloadattributionissuewhereapointloaddefinedinthemiddleofthewallpaneldidnot

properlyattributetothewall. FixedanissuewiththedetailreportwheretheCbvaluewasnotbeingdisplayedforcoldformedmembers. CorrectedaproblemwhereunbracedlengthvaluesenteredinRISA‐3Dwerenotgettingsavedwhenthemodel

wasbroughtbackandforthfromaRISAFloormodel.Issueaffectedbeams,butnotcolumns. FixedaunitsconversionproblemassociatedthedisplayofsomeofthefactorsforwoodPerforatedandFTAO

wallpanelsintheirdetailreports. CorrectedanissuewheretheInternalForceSummationToolwasonlyupdatingunitsduringsolutiontime.

Therefore,switchingunitswithanactivesolutioncouldresultinincorrectforcedisplayuntilthemodelwasre‐solved.

CorrectedsomeissueswiththeAppendcommandwhichcouldcauseduplicationofwallpanellabels. Fixedaprogramcrashwhichoriginatedfromlargenumberofbars(200+)inaCustomRebarLayout. CorrectedanissuewithFTAOandPerforatedwallswherewallswithmultipleopeningsoroffsetopenings

couldreportincorrectunitshearvaluesorholddowns/chordforces. FixedanissuewhereRISA‐3Ddetailreportsforwoodwallpanelswouldbeclearedwhenentering

RISAFoundation. Correctedanissuethatcouldcausemodelswithalargenumberofinstabilitiestocrashduringanenvelope

solution. Correctedadisplayissuewiththemomentdiagramforslendermasonrywallsthatdivergedduringslender

wallcalculations. CorrectedanissuewhereusingtheSectionSetsspreadsheettomodifydatabaseshapedatawasnot

automaticallyclearingthestiffnessmatrix. Correctedissuewheresomespreadsheetoperations(Fillblock,etcetera)werenotavailableinsome

spreadsheets(DesignRules).

Page 18: Release Notes 3D

ReleaseNotes

Correctedanissuewiththewarninglogwheretheprogramwasincorrectlygeneratingmessagesaboutthestrapsforstackedwallnotproperlyliningup.

Correctedanissuewiththegraphicalcopycommandwherethewallstrapswerenotgettingcopiedwiththewallpanel.

CorrectedanissuewheretheFv'forwoodmemberscouldbeincorrectlydisplayedinthememberdetailreportsforGlu‐Lammembers.

CorrectedanissuewiththeFTAOwoodshearwallswheretheprogramwasenforcingthe2w/hlimitationsbasedonthefullheightofthepierratherthantheopeningheight.

CorrectedanissuewithPerforatedwallswherethewallcapacityreductionfactor(2w/h)wasbeingappliedtothechordforces.

Correctedanissuewhereolderfiles(v8.0orolder)thatareopenedin8.1or8.1.1maygettheirwindcodeorseismiccodereadinincorrectly.Filescreatedinversion8.1andnewercouldstillhavethewrongwindandseismiccodesdisplayediftheyareopenedwithanolderversionoftheprogram.

Correctedmeshingerrorsassociatedwithwallpanels. FixedabugwhereduplicatenodeswerebeingcreatedduringthetransitionfromRISAFloortoRISA‐3D. FixedaproblemwherethediaphragmloadsfromaRISAFloormodelwithsavedresultswouldincorrectlyread

thetransientloadsinRISA‐3D. CorrectedaproblemintheCanadiansteelcodecalculationsformembersclassifiedas"slender".Thisallowable

momentcapacitywasbeingreportedasnegativewhenitshouldhaveprovidedanerrormessage. Correctedanissuewiththeprocessingofmultiplepartiallengthdistributedloadsontaperedmembers.Issue

couldresultinanun‐reportedlossofinputforcesifanodeoccurredatthelocationoftheloadtransition.

Version 8.1 Enhancements / Corrections

Enhancements

Addedtheabilitytomodelwoodshearwallswithopenings,incorporatingthreedesignoptions:segmented,perforatedandforcetransferaroundopenings.

Addedflexiblediaphragmanalysis/loadingoptionforRISAFloordiaphragmsthatarebroughtintoRISA‐3D AddedwooddiaphragmdesignforflexiblediaphragmsthatarebroughtfromRISAFloorintoRISA‐3D. AddedacustomizablegraphictoolbarwithnewPlotOptionsbuttonforeasiergraphicalviewofresults. Addedanautomaticregiongeneratorforshearwallpanelstoexpeditethecreationofregionsespeciallyfor

wallsthathaveopenings. AddedEC32005Eurosteelcode. AddedBSEN2004Euroconcretecode. AddedNBC2005CanadianautomaticWindandSeismicloadgeneration. AddedaShearStiffnessAdjustmentfactorforwoodshearwallstoallowtheusertoadjusttheFEMstiffnessof

thewallstomatchthecodeequationsreportedinthewalldetailreports. AddedCustomWoodSpeciesforcommonlyusedcompositelumberspecies. Addedre‐designlistsfornewlyaddedcompositelumberSpecies.

Corrections

Correctedanerrorwithplatecornerreleaseswhichcausedtheplatemomentreleasestobereversed.i.e.acornerreleasethatwasspecifiedasanMxreleasewasreallyanMyrelease.

CorrectedacompatibilityissueintheconcretecodesettingsbetweenthecurrentversionandRISA‐3Dversion7.0.Issuecouldcauseanincorrectconcretecodetobechosenwhenreadingaversion7.0(orolder)fileintoversion7.1or8.0.Correctiononlyappliestoolderfilesbeingopenedinthenewversion(8.1orhigher).Newfilesopenedinoldversionscanstillexperiencetheissue.

Page 19: Release Notes 3D

ReleaseNotes

Version 8.0.3 Enhancements / Corrections

Enhancements

Enhancedthestatusbardisplayformulti‐monitororoddresolutionscreens. Enhancedmasonrydetailreportstogivemoreclearandrelevantoutput. Enhancedthemasonryhorizontalshearreinforcementgraphicsinthewallpaneleditor. Improvedwoodwallpaneldetailreportstogivemorerelevantoutput. Addedgeneralwallpanelregiondetailreports. Enhancedwoodwallpaneldetailreporttoexplicitlyshowchordandholddownforceswiththecontrolling

loadcombination. Improvedtrussgeneratortoallowusertospecify“Segment”forunbracedlengths. Improvedtrussgeneratortorecognizetriangulartrussesandtherebynotcreateduplicatechordendjoints. Improvedwallpanelmeshertoaccountforjointswithboundaryconditionsthatfallwithinwallpanels. Modifiedthewaywoodscheduleswerechecked,thusremovingunnecessarywarningsfromthewarninglog. Addedcodetopreventcreationofnon‐rectangularwallpanelregionswhichcouldcauseerrors. Enableduserstodeletepointloadsusinggraphicaldeleteloadfeature. ImprovedloadgenerationtreatmentofBaseElevationtoproperlyallowfornegativeelevations. EnhancedtheWallPanelreactionstoincludethedisplayofthetotalmomentreactionasmeasuredfromthe

midpointofthewallbase. ModifiedMasonryWallPaneldetailreportstomoreconsistentlyreportoutofplaneforcesonaperfootbasis

insteadofabasingitonthedistancebetweenreinforcingbars.

Corrections

Fixedabugwheretheself‐weightofmasonrywallpanelshadvaluesreversedbetween140pcfgroutand105pcfgrout.

Correctedsomeunitconversionsfromimperialunitstometricfortheoutputinmasonrydetailreports. Fixedabugwheretheallowablestressincreasefactorwasnotbeingconsideredcorrectlyformasonrywall

panels. Correctedcalculationforstressinthesteelforoutofplanecalculationswithbarsinbothfacesofmasonrywall

panels. Fixedmiscellaneousinconsistenciesbetweenregioneditorinputandthedetailreportoutputformasonry. CorrectedaWallPaneldetailreporterrorwhereregionsthatwereauto‐splitcouldreportanover‐

conservativeaxialforce. Correctedgraphicsinmasonryoutofplanedetailreportfor"bothfaces"and"staggered"locationsof

reinforcement. Fixedabugwherewallpanelreactionswerenotbeingincludedinresponsespectraanalysisscalingofbase

shears. Correctedunitsconversionerrorwiththey1andzvaluesincustomrebarlayouts. FixedaunitsconversionproblemwiththeCanadiancodewherethemomentvaluewasreportedasanegative

number. Removedwallpanelendreleasesbecausetheywerebeingappliedincorrectly.Theywillbeaddedatalater

time. Modifiedholddowndesignanddatabaseprocedureforwoodwallpanelstoeliminateerrors. Correctedover‐conservativewoodwallpanelchordforcecalculationincertaincases. Correctedanissueintheloadcombinationsspreadsheet,whereaddingalineinthespreadsheetwould

confuseanynestedloadcombinationsbelow. Fixedabugthatwouldcausedistributedloadstobecutoffifamodelmergewasperformedonnon‐physical

members. CorrectedanerrorwhereduplicatenodeswouldbecreatedinaRISA‐3DmodelthatcameinfromRISAFloor.

Page 20: Release Notes 3D

ReleaseNotes

CorrectedaK‐factorissuewhereNodeswithblanklinesintheBoundaryConditionsspreadsheetwerebeinginterpretedasrestrainedjointsfortheKapproximation.

Enhancedprogrammesherforwallpanels,eliminatingerrors. Fixedaprobleminwallpaneldetailreportswhereenvelopeforceandmomentdiagramwerereportedasa

maximumofbatchforces,asopposedtoanabsolutemaximumofbatchforces.Issueoccurredonlyforwallpanelsdefinedwitha"General"materialtype.

FixedMiscellaneousdatabaseanddefaultissuesassociatedwiththeWoodWallDesignRules. CorrectedanissuewiththewallpaneldetailreportswheretheWindowTitlecouldlistthewrongwallpanel

label. FixedaprobleminwooddesignwheretheRBcalculationwascomputedasifthebottomflangewasin

compressionwhenthetopflangewasactuallyincompression. Correctedabugthatwascausingsurfaceloadsappliedtowallpanelstobeneglectedovertheareaofthe

opening.

Version 8.0.2 Corrections

CorrecteddimensionsinEuroSteeldatabaseforHD360x147,HE1000A,HE1000AA. Correctedthecontoursandcontourlegendsdisplay. FixedabugwhereallwallpanelsurfaceloadswerebeingplacedinBasicLoadCase1regardlessofthe

specifiedBLC. Fixedabugwherewallpanelthicknesschangesdidnotautomaticallyclearthestiffnessmatrix Fixedabugwhereenvelopeandbatchsolutionswereconsideringthelastloadcombinationasthecontrolling

oneforwallpanelsonly. Correctedmiscellaneousholddowndatabaseerrorsforwoodwallpanels. Correctedresultsforwallpanelswithsurfaceloadsappliedinthelocalaxisdirections. CorrectedWallPanelforcediagramsindetailreportsformodelswhentheZ‐axiswassettovertical. Correctedthe"d"valuecalculationformasonrywallpanelsdesign. Correctedoutofplanestrengthdesignformasonrywallpanels. Correctedthedisplayofthecontrollinglocationmasonrywallpaneldesign. Correctedmiscellaneouswallpanelmeshingerrors.

Version 8.0.1 Enhancements / Corrections

Addedoptiontoviewthelocalaxesofwallpanelelements. Activatedthe"DetailReportForCurrentItem"incaseswhereitwasnotworking. Changedthesortingofjointcoordinatestoincludewallpanelnodes Correctedthegraphicaldisplayofwallpanelsurfaceloadsandreactionvalues Correctedthedisplayofgroutweightinthewallpaneleditor. Correctedthetopvalueofthewallpanelsurfaceloadtoconsidertheloadfactor. CorrectedtheinteractionbetweenRISA‐3DandRISAFoottoallowfootingdesignwithinRISA‐3D. Correctedthecalculationofrz(radiusofgyrationaboutprincipalaxis)ofcustomsingleanglescreatedinRISA‐

3D. CorrectedtheimportingofsteeljoistsfromaSTAADfile. Fixedabugwheretheprogramwasnotproperlyre‐assigningarebarlayoutfornamingconflicts. Correctedanissuewherecrackcontrolrequirementsforconcretememberscouldproducetightbarspacing. CorrectedprintingofProjectGridsandWallPanelSurfaceLoads.

Page 21: Release Notes 3D

ReleaseNotes

Version 8.0 Enhancements / Corrections

Walls Panels Enhancement

AddedWallPanels,givingusertheabilitytomodelentireportionsofwallswithoutusingplates. AbilitytocreateMasonrywallswithopeningstogetreinforcementdesignforinplaneandoutofplane

forces,aswellastheabilitytodesignlintels. AbilitytocreateWoodwalls(currentlywithoutopenings)andgetdesignresultsforinplaneandoutof

planeloads AbilitytocreateGeneralwallswithuniformpropertiesandopeningsforanalysis.Awayforanalysisof

concretewalls.

Interface & Graphics Enhancements / Corrections

Changednotationfor“projected”globalaxesfromL,V,andHtoPx,Py,andPz Correctthedisplayofincorrectstressblockselectioninthedetailreports.

Interaction Enhancements / Corrections

AddedtheabilityfortheLbyyandLbzzvaluestobetransferredfromRISAFloorwhenusingtheDirectortool. AddedtheabilityfortheRISAFloorselectionofan"inactivediaphragm"tobesavedbetweentheRISA3D

/RISAFloortransfer.

Concrete Design Enhancements/Corrections

Correctedconcretebeamcodecheckstoconsiderthelastspanincontinuousconcretebeamsforthegoverningcodecheck.Thesteelreinforcingdesignoptimizationwasnotaffected.

CorrectedtheShearUCtonotalwaysbetakenatthefirstsectionofacontinuousbeam.

Sloping Members

AbilitytobringslopingmembersoverfromRISAFloorforanalysis.

Miscellaneous Enhancements / Corrections

Addedorthotropicplates.PlatematerialswithinconsistentEandGwillnowusebothintheelementstiffnessformulationratherthaninternallydefiningGbasedontheenteredEvalue.

ChangedEmincalculationforSCLmembers Addedwarningtopreventpoorlyformedplatefrombeingextractedintoacorruptedsolidelement. Fixedabugwherechangestothe"DetachfromDiaphragm"optiondidnotautomaticallyclearthestiffness

matrix. CorrectedpossiblecorruptionoftheReportNamedatabasewhichcouldresultinseeminglyunrelatedmemory

errors. CorrectedprintingfortheProjectGridspreadsheet FixedUnityCheckforcolumnsundertheMexicancodethatneedrebarclosetothemaximumspecified. CorrectedanissuewhereeditingamodelintheembeddedversionofRISAFoundationcouldtemporarilybreak

theexistingRISA3Ddeflectiondiagram. CorrectedmemberorientationissueassociatedwiththeopeningofRISA‐2DfilesinRISA‐3D

Page 22: Release Notes 3D

ReleaseNotes

CorrectedanissuewiththeMaterialTakeOffresultswhichwouldoccuranytimemorethan500sectionsetswereusedinamodel.

Removedthepotentialfor"paddedspaces"fromdialogboxes.Whenthesefieldswerebeingpaddedthiswouldpreventuserfromenteringdatainthosefields.

CorrectedthedisplayofsavedColdFormedcodechecks.Phiwasnotbeingproperlystoredintheresultsfile.

Version 7.1.3 Corrections

CorrectedabugthatcouldresultinacrashwhileusingtheembeddedversionofRISAFoot3.0.TheproblemonlyoccurredwhenoneoftheLoadCombinationsusedforfootingdesignincludedanAISC13thEditioncodecheckwiththe“adjuststiffness”optionoftheDirectAnalysismethod.

CorrectedaseriousbugthatcouldresultinthedeletingofembeddedRISAFoundationdata.IfaRISA‐3DfilewithembeddedRISAFoundationweresavedwithouthavingfirstviewedtheFootingdataduringthatsession,thentheFoundationinformationwouldNOTbeembeddedinthe3Dfile.

CorrectedabugrelatedtothevalidationofRISAFootversion3.0licensing.PreviouslythenetworkversionofRISAFootwasnotcorrectlyauthorizing.

Correcteda2ndbugrelatedtoRISAFootauthorizationthatrelatedtolaunchingRISA‐3DfromwithinaRISAFloorsession.

Correctedabugrelatedtothereadingoftheresultsfile.Therewereinstanceswheresavedresultswerebeingdiscardedevenwhentheywerepresentandvalid.

Correctedacrashonthere‐useofeigensolutionresultsfortheaccelerateddynamicsolver. Correctedabugwiththeoptimizationofconcretereinforcement.Thebugwouldhavepreventedtheprogram

fromaddingsteelthatisabovetheminflexuralsteelrequirements. CorrectedaSteelDatabaseerrorinAISCDB32.FILassociatedwithHSS6.625x0.375.

Version 7.1.1 Corrections

CorrectedabugwheretheuseoftheAutomaticResponseSpectraScalingFactorinasolutioncouldcauseacrash.

CorrectedabuginthesingleanglecodethatdidnotallowforsingleanglestobendabouttheirGeometricaxesevenwhenthiswasspecificallyrequestedbytheuser.

Version 7.1 Enhancements / Corrections

Interface and Graphics Enhancements / Corrections

ImproveddialogbehaviorbyhighlightingtheUse?CheckboxesandaddedinaClearUseBoxesbutton Fixedabugwiththerenderingofdeflectiondiagramsforpipeshapes Dynamic_graphicsintheINIfile

Steel Design Enhancements / Corrections

AddedchangestotheAISCdatabasebasedonthe13thEditionManual.IncludingroundHSSdesignthickness. AddedaRollBackOnCancelactiontotheGlobalParameters–Codesettingstoproperlyaccountforcases

whereuserschangefrom13thEditionASDto13thEditionLRFDandcancelthechangebeforeexiting ChangedlogicforusingRvalueforcoldformed/lightgagesteel SlendernesschecksforIndiancodeIS800 UpdatedP‐DeltaerrormessagesforAISC13thEditionManual CorrectedKvaluecalculationforIndiancode.Onlyaffectscantilevertypeendconditions. CorrectedKcalculationissuethatcouldcauseacrash

Page 23: Release Notes 3D

ReleaseNotes

Concrete Design Enhancements / Corrections

AddedACI2005 ChangedFyintherebarlayoutdialogsothatitistiedtostressunitstobeconsistentwithdefinitionofFyin

theDesignRules CorrectedwarningsinshearrebarlayoutsforFloor ConcreteT‐beamsmodifiedinRISAFloor(negativereinforcementoverL/10) Fixedbugsrelatedtorebaroptimizationforextremely,extremelywidebeams Correctedbugwhereuserdefinedlayoutsmaynotbecorrectlyinterpretedattheexactendofthemember.

Onlyoccurredwhensupporthadawidthofzero(i.e.boundaryconditionsupport). Correctedbarcalloutsforcustomcolumnrebararrangements.Onlyaffectedbarsdefinedfromleftandright

sideofcolumns.Barlayersdefinedbasedonthebottomortopofsectionwerenotaffected.

Solution & Analysis Enhancements / Corrections

AddedroutinetoclearstiffnessmatrixforcaseswhereDesignparameters(membertypeorswayflag)couldresultinarequiredchangetothestiffnessmatrix.ShouldonlyaffectAISC13thEdition.

InternalForceSummationtooladjustedtoALWAYSbedefinedLefttoRightorToptoBottom

Loading Enhancements / Corrections

IncreasedLoadCombinationlimitto5000 Addedcheckboxforcopyingloadswhenusingtranslational,rotational,ormirrorcopyoptions AddedtorquePointLoadsintotheprogram ChangedSeismicUseGrouptoOccupancyCategoryforASCE7‐2005.

Miscellaneous Enhancements / Corrections

CorrectedbugwiththeMirrorcommandthatcouldcreatepoorlydefinedsolidelements. Correctedabugwheretheprogramwasincorrectlyhandlingduplicateshapes.Thisbugonlyoccurredwhena

filewasopenedwhichcontainedashapethatmatchedthename(butnottheproperties)ofanexistingdatabaseshape.Programwouldincorrectlyre‐assignthemembertothedatabaseshape.

CIS/2Detailing CFcorrectionforSCLlumberin2005NDS AddedinbetterstatusbarsupportforDualMonitors AddedrestrictionsonspreadsheetprintingforDemoversions.Nowlimitedtoamaximumof5rowsforeach

spreadsheet. Correctedreportprintingtore‐adjustreportwidthstoallowforwider/Landscapepages Correctedabugwherecopyingandpastingfromresultsbrowserscouldresultinamemoryerrorbasedonan

“outofrange”spreadsheetsetting KeyIDaddedtoinputfile DemoVersionswillnowrunoutofHKEY_Current_UserifLocal_Machineisunavailable Abilitytoturnoffthetime/datestamp Logofmembersthathadinvalidormissingdesignlists Addedawarninglogthatwilltellyouwhichentrieswerenotreadproperlyorcausedthefiletobeconsidered

"corrupted" Correctedabugwheredynamicsolutionscouldcausesome"hotkeys"tostopfunctioningincombined3D/

Floormodels Correctedanerrorwithreadingdefaultprogramsettingscreatedbyanolderversion(pre‐7.0) CorrectedbugwherePlatesSpreadsheetwouldnotopenproperlyfromtheMainMenutoolbar

Page 24: Release Notes 3D

ReleaseNotes

Correctedbuginthetrussgeneratorthatmis‐calculatedchordcentroidswhenthe'MaintainOut‐to‐Out'distanceoptionwasselected

AddedcodetopreventinfiniteiterationissuesforfootingsandOne‐Wayelements AddeddialogtocalculatedetailingoffsetsforCIS/2translator

Version 7.0.2 Enhancements / Corrections

Miscellaneous Enhancements/Corrections

PrimarilyreleasedtoaddresssomecorrectionsintheRISAFoundationprogram.RefertoRISAFoundationreleasenotesformoreinformation.

Correctedalengthconversionbugintherebardatabase.Iflengthunitswereotherthanfeet,theprogramhadbeenerroneouslyconvertingrebarcutofflengthsenteredinasa%oflength.

AddedSecurityCodesforREVITStructureVersions.Thereisnodirectimpacttotheprogram. EnhancedCIS/2linktoallowforcompleteroundtripdatatransfer. Fixedabuginthesubspacesolversothatmodelswithmorethan100DOFs,butlessthan40masstermswill

solveproperly.

Version 7.0.1 Enhancements / Corrections

Enhanced Loading Features

AddedASCE2005/IBC2006WindLoadingCode AddedASCE2005/IBC2006SeismicLoadingCode AddedASCE2005/IBC2006ResponseSpectra AddedMexicanSeismicLoadingCode AddedMexicanResponseSpectra NegativeBaseElevationsforCalculationofWindandSeismicForcesareNowAllowed SeismicLoadAssociatedwiththeBaseoftheStructureisNowDisplayed AddedAbilitytoIgnoreBaseWeightinCalculationofSeismicLoads

Enhanced Analysis Features

AddedSubmeshingofSolidElements AddedPlateMomentReleases IncreasedProgramLimitsforJoints,Plates,andSolidsto100,000Each

Enhanced Steel Design Features

CorrectiontotheAISC‘Cb’CalculationwhenUsingthe"Segment"Code CorrectiontoEC3SteelCodeCheckforColumnswithBendingandTension

Enhanced Concrete Design Features

AddedMexicanConcreteDesignCode

Interaction With Other Programs

AddedIntegrationCapabilitywithRISATowerProgram

Page 25: Release Notes 3D

ReleaseNotes

AddedMemberDetailingInformationtobeUsedwithUpcomingCIS/2Translator

Miscellaneous Enhancements

AddedGraphicalFilteringforShapeOptimization DoubleWheelClickNowCallsUpaFullScreenView RenderButtonIsNowa3‐WayToggleBetweenWireFrame‐ColorCoded‐Rendered AddedINIOnlyOptiontoTurnofftheDynamicMouseGraphicsFeatures EnhancedHandlingofInstabilitiesintheSparseSolversoTheyAreLockedandtheSolutionContinues

Miscellaneous Corrections

CorrectedaBugwiththeMouseWheelPan/ZoomthatResultedInNumerousCrasheswhenColorCodingLegendsWerePresent

CorrectiontotheUnitsConversionofSavedDrawingGridData CorrectiontotheUnitsConversionforParametricConcreteShapes CorrectiontotheAreaLoadAttributionforMemberswithPartialAreaLoadsandRigidEndOffsets

Version 7.0.0 Enhancements / Corrections

Enhanced Loading Features

AddedASCE‐72005LoadCombinationstotheLoadCombinationGenerator CorrectedanerrorwiththeattributionofMemberAreaLoadsthatwaseliminatingtheloadassociatedwith

RigidEndOffsets

Enhanced Analysis Features

AddedaSparseSolvertospeedupsolutiontimesandreducememoryrequirements Addedan8‐nodeSolidElement

Enhanced Steel Design Features

AddedAISC13thEditionSteelCode Abilitytouse1.6*P‐DeltaeffectforASDDesign Abilitytoreduceflexuralstiffnessforcertainmembersoflateralresistingsystembasedontheaxial

loadinthemembers(thisisdoneonaLCbyLCbasis) Abilitytoreduceaxialstiffnessforcertainmembersofthelateralresistingsystem

ChangedtheBSsteelcodetodistinguishbetweenHandIsectionswhenchoosingwhichstrutcurvetouse

Enhanced Wood Design Features

AddedNDS2005WoodCode Correctedabuginthe2001wooddatabasethatwasusingalowerFcvalueforDFL#2PostandTimbers

Miscellaneous Enhancements / Corrections

CorrectedabugwiththeBlockFillcommandthatwasonlyallowingthefirst3cellsoftheblocktobefilled Correctedabugwiththeinternalforcesummationtoolthatcouldcauseacrashformodelswithtriangular

plateelements

Page 26: Release Notes 3D

ReleaseNotes

CorrectedabugwherechangingtheMemberTypeofaconcretememberdidnotclearthestiffnessmatrix