REGENERATIVE BLOWERS - PRESSURE SCL R20 / R30 / R40 - fpz … · FPZ, Inc. 150 N. Progress Drive...

2
FPZ, Inc. 150 N. Progress Drive Saukville, WI 53080 USA Tel. (262) 268-0180 [email protected] www.fpz.com - For proper use, the blower should be equipped with inlet filter and relief valve; other accessories available on request. - Ambient temperature from +5° to +104°F. - Specifications subject to change without notice. Model Maximum flow Scfm Installed power Hp Maximum differential pressure p ( In WG) Noise level Lp dB (A) (1) Overall dimensions H Weight 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 3500 rpm 2900 rpm 3500 rpm 2900 rpm 3500 rpm 2900 rpm 3500 rpm 2900 rpm Inches Lbs 1 ½ 1 ½ 161 161 13. 4 .5 2 2 140 69.2 15.58 57.3 3 - 191 - 72.8 15.55 66.1 3 3 141 170 72.8 16.22 77.2 4 4 201 201 73.3 1.9 88 (1) Noise measured at 1 m distance with inlet and outlet ports piped, in accordance to ISO 3744. SCL R20 / R30 / R40 SN 2464-4 1/2 STANDARD FEATURES - Low weight cast aluminum construction. - Quiet operation with integral inlet and outlet muffling. - Recognized TEFC - cURus motor. - High efficiency / low noise impeller design. - No lubrication / maintenance required. - Allowed ambient: +5 °F to +104 °F. - Mountable in any plane. OPTIONS - Remote drive models (belt or coupling). - Special voltages. - Surface treatment or plating. - Gas tight sealing. - Special designs available. ACCESSORIES - Inlet and/or inline filters. - Additional inlet/outlet silencers. - - Flow converting devices. - Optionals connectors Dimensions in inches. Dimension for reference only. Model a b c d e f G I m n o p1 q t 11.14 12.17 6.57 1.85 1” ¼ NPT 12.56 7.36 0.71 0.87 M6 09 13.78 7.76 0.71 s l G d c a f e b r øm p1 o n q H 3x120° øu t MD 1 1 0.87 5 91 REGENERATIVE BLOWERS - PRESSURE 3.54 0.39 5.91 7.87 0.71 1.77 13.58 0 R2 -MD 35 R20-MD 41 9. 2 5 8. . 2 7 0.39 0.39 R30-MD R40-MD 14.65 13.62 1.85 1.85 9. 2 5 8 . 2 7 9. 2 5 8 . 2 7 1” ¼ NPT 1” ¼ NPT 3.54 3.54 5.91 5.91 7.87 7.87 3.94 4.33 r 1.77 1.77 0.87 s M8 M6 u . 7. 8.86 R30-MD R40-MD 54 65 69 81 170 72.2 68.5 66.5 69.7 70.8 39 70 .2 SERIES 71.3 Relief valves. 8 ® BLOWER TECHNOLOGY

Transcript of REGENERATIVE BLOWERS - PRESSURE SCL R20 / R30 / R40 - fpz … · FPZ, Inc. 150 N. Progress Drive...

FPZ , In c . 1 50 N . Pr ogr es s Dr ive Sa uk v i l l e , WI 5308 0 USA Tel . (262 ) 26 8-01 80 usa@ fpz .c o m www.fp z .c om

- For proper use, the blower should be equipped with inlet filter and relief valve; other accessories available on request. - Ambient temperature from +5° to +104°F. - Specifications subject to change without notice.

Model Maximum

flow Scfm

Installed power

Hp

Maximum differential pressure

∆p ( In WG)

Noise level Lp dB (A)

(1)

Overall dimensions

H Weight

60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 3500 rpm 2900 rpm 3500 rpm 2900 rpm 3500 rpm 2900 rpm 3500 rpm 2900 rpm Inches Lbs

1 ½ 1 ½ 161 161 13. 4 .5 2 2 140 69.2 15.58 57.3 3 - 191 - 72.8 15.55 66.1 3 3 141 170 72.8 16.22 77.2 4 4 201 201 73.3 1 . 9 88

(1) Noise measured at 1 m distance with inlet and outlet ports piped, in accordance to ISO 3744.

SCL R20 / R30 / R40

SN 2464-4 1/2

STANDARD FEATURES - Low weight cast aluminum construction. - Quiet operation with integral inlet and outlet

muffling. - Recognized TEFC - cURus motor. - High efficiency / low noise impeller design. - No lubrication / maintenance required. - Allowed ambient: +5 °F to +104 °F. - Mountable in any plane.

OPTIONS - Remote drive models (belt or coupling). - Special voltages. - Surface treatment or plating. - Gas tight sealing. - Special designs available.

ACCESSORIES - Inlet and/or inline filters. - Additional inlet/outlet silencers. - - Flow converting devices. - Optionals connectors

Dimensions in inches. Dimension for reference only.

Model a b c d e f G I m n o p1 q t

11.14 12.17 6.57 1.85 1” ¼ NPT 12.56 7.36 0.71 0.87 M6 09 13.78 7.76 0 .71

sl

G

d

c

a

fe

b

r

øm

p1

o

nq

H

3x120° øu

t

MD

11

0. 87 5 91

REGENERATIVE BLOWERS - PRESSURE

3.54 0.39 5.91 7.87 0.71 1.77 13.58 0R2 -MD

35 R20-MD 41

9 . 2 5 8. . 2 70.390.39

R30-MD R40-MD 14.65

13.62 1.85 1.85

9 . 2 5 8 . 2 79 . 2 5 8 . 2 7

1” ¼ NPT 1” ¼ NPT

3.54 3.54

5.91 5.91

7.877.87

3.944.33

r

1.77 1.77 0.87

s

M8

M6

u

. 7.

8.86

R30-MD

R40-MD

54 65

69 81

170 72.2

68.5 66.5

69.7 70.8

39

7 0 .2

SERIES

71.3

Relief valves.

8

®

BLOWER TECHNOLOGY

FPZ , In c . 1 50 N . Pr ogr es s Dr ive Sa uk v i l l e , WI 5308 0 USA Tel . (262 ) 26 8-01 80 usa@ fpz .c o m www.fp z .c om

Curves refer to air at 68°F temperature and 29.92 In Hg atmospheric pressure (abs) measured at inlet port. Values for flow, power consumption and Data subject to change without notice.

CAPA

CITY

A

BSO

RBED

P

TEM

PERA

TURE

INCR

EASE

SN 2464- 2/2

p

psig

0

1

2

3

4

5

6

7

0

20

40

60

80

100

120

140

160

180

220

0 Scfm

In W

G

20 40 60 80 100 120

60 Hz

3

2

3

4

p

psig

0

1

2

3

4

5

6

7

In W

G

0

20

40

60

80

100

120

140

160

220

Hp

50 Hz

0 0.5 1 1 5 2 2 5 3 3 5 4

p

psig

0

1

2

3

4

5

6

7

0

20

40

60

80

100

120

140

160

220

0 20 40 60 80 100 120 140 160 180 °F

In W

G 50 Hz

p

psig

0 1

2

3

4

5

6

7

In W

G

0

20

40

60

80

100

120

140

160

220

0 0.5 1 Hp

60 Hz

1.5 2 2.5 3 3.5 4

p

psig

0 1

2

3

4

5

6

7

0

20

40

60

80

100

120

140

160

220

0 20 40 60 80 100 120 140 160 180 °F

In W

G

p

psig

0

1

2

3

4

5

6

7

0

20

40

60

80

100

120

140

160

180

220

0 Scfm

50 Hz

In W

G

20 40 60 80 100

1 1/2

2

4

3

D SERIES

. . .

REGENERATIVE BLOWERS - PRESSURE

OW

ER

1 1/2

R20-MD

R20-MD R20-MD

4

R40-MD

R30-MD

R40-MD

R30-MD

R40-MD

temperature rise: +/-10% tolerance.

R40-MD R 0-MD 3

60 Hz

R40-MD R30-MD

R20-MD

R30-MD R40-MD

R20-MD

DR -M20

R30-MD

SCL R20 / R30 / R40M

®

BLOWER TECHNOLOGY