REFRIGERANT SERVICE TOOLS - asada.co.jp · Possible to detect a small leak of each ... Indicator...

10
REFRIGERANT SERVICE TOOLS GAS LEAKAGE DETECTION / PREVENTION

Transcript of REFRIGERANT SERVICE TOOLS - asada.co.jp · Possible to detect a small leak of each ... Indicator...

Page 1: REFRIGERANT SERVICE TOOLS - asada.co.jp · Possible to detect a small leak of each ... Indicator displays the value of leak in 6 stages. ... REFRIGERANT SERVICE TOOLS System ...

REFRIGERANT SERVICE TOOLSGAS LEAKAGE DETECTION / PREVENTION

Page 2: REFRIGERANT SERVICE TOOLS - asada.co.jp · Possible to detect a small leak of each ... Indicator displays the value of leak in 6 stages. ... REFRIGERANT SERVICE TOOLS System ...

GAS LEAKAG

E DETECTIO

N &

PREVEN

TION

MAN

IFOLD

S, CHAR

GIN

G H

OSES &

VALVESVACU

UM

PUM

PSR

EFRIG

ERAN

T SERVICE TO

OLS

36

Just connect to the manifold to useas a system analyzer !!

Automatic Superheat・Subcooling calculation

■ Automatically calculating Superheat/Subcooling temperatures of 97 kinds of refrigerants.

Measure the temperature of both low /high pressure ports

■ Dual K -Type temperature - compensated sensors allow for simultaneous measurement at both suction and discharge ports.

Addable new refrigerant data

■ Data of new refrigerant which is about to develop can be added by USB port.

■ Power off time selectable.

Auto switch OFF function Altitude correcting function

Pressure 0~4.8MPa

Connecting port size 1/4" Flare (UNF 7/16− 20 TPI)

Super heat / Subcool

※Low pressure & High pressure with be displayed at the same time.

Refrigerant Temperature

Comdensation temperature / Evaparration temperature

Refrigerant pressure

Applicablerefrigerant

R11, R12, R13, R21, R22, R23, R32, R41, R113, R114, R115, R116, R123, R124, R125, R134a, R141b, R142b, R143a, R152a, R218, R236ea, R236fa、R245ca, R245fa, R290, R401A, R401B, R401C, R402A, R402B, R403A, R403B, R404A, R405A, R406A, R407A, R407B, R407C, R407D, R407F, R408A, R409A, R410A, R410B, R411A, R411B, R412A, R413A, R414A, R414B, R416A, R417A, R418A, R419A, R420A, R421A, R421B, R422A, R422B, R422C, R422D, R423A, R424A, R425A, R426A, R427A, R428A, R434A, R438A, R500, R501, R502, R503, R504, R507, R507A, R508, R508A, R508B, R509, R509A, R600, R600a, R601, R601a, HFO-1234yf, R1234ze, R1233zd, R1270, R227ea, R407E, R407F, R409B, R437A

Pressure sensing resolution −0.1psi, 0.01bar, 1kPa, 0.1MPa, 0.01kg / cm2

Pressure sensing accuracy 0.5% / FS (25°C) • 1.0% / FS (12~55°C) • 2.0% / FS (−40~120°C)

Pressure Proof : 6.8MPa / Burst : 10.3MPa

Temperature sensor −73~315°C (K - type)

Temperature display resolution 0.1°C Temperature

accuracy±1°C

Temperature Operating :−20~ 50°C / Storage :−29~77°C

Weight 0.53kg (Body)

Power 9V Alkaline battery

Standard accessories System Analyzer Ⅱ, Thermocouple (K -Type)× 1, Adapter (1/4"× 5/16")×2

■ Ideal for job in dark site with back light on.

Back light

110mm

200mm

Simple operation just connect to manifold to judge the unit condition !!

From refrigerant pressure & temperature, automatically calculate Superheat & Subcooling by easy valve control !!

System AnalyzerⅡ PAT.

Refrigeration system analyzer

R32applicable

Page 3: REFRIGERANT SERVICE TOOLS - asada.co.jp · Possible to detect a small leak of each ... Indicator displays the value of leak in 6 stages. ... REFRIGERANT SERVICE TOOLS System ...

GAS LEAKAG

E DETECTIO

N &

PREVEN

TION

MAN

IFOLD

S, CHAR

GIN

G H

OSES &

VALVESVACU

UM

PUM

PSR

EFRIG

ERAN

T SERVICE TO

OLS

37

R32applicable Freon HFO-1234yf Infrared sensor

Applicable refrigerantR410A, R407C, R404A, R507A, R134a, R12, R22, R500, R502, HFO1234yf, R32, R245fa, etc

Detection method Infrared type

Gas introduction method Gas suction system

Sensitivity High :4g / yr, Medium:7g / yr, Low :14g / yr, CM mode :3g / yr

Power Rechargeable lithium battery

Time Reaction time : less than 1sec / Warm up : about 30 secs

Detection method Buzzer & 9 staged LED

Weight 495g

Temperature range working :0 ~50°C / storage :–10~60°C

Standard accessories Leak check bottle, Spare filter×5, AC adapter, Body cover, Storage case

High-performance &high-sensitivity infrared sensor !!Long life !!

For refrigerant leak detection of large fridge - freezer • large A /C • commercial A /C •

package A /C • room A /C • showcase • refrigerator • vending machine • car A /C.

With LED light at the probe tip, can search for refrigerant leakages in dark site such as,in internal system, ceiling, basement, etc.

Alarm is changeable. (ON /OFF)

PEEKHOLD Mode

Auto sensitivity switching mode

CM mode

LED light at the probe tip

■ When you press 【PEEKHOLD】 button during detecting, hold the display at the maximum amount of leakage. LED indicator stops at the point of the highest refrigerant concentration, and always shows the highest refrigerant concentration during the operation. Easily identify the leak location in this way.

■ Depending on the amount of leakage, 3 - stages - sensitivity automatically switching. It can always detect with optimal sensitivity sensor. Press 【SENS】 and hold for 2 secs, for Auto / Manual change. For identifying the exact leakage position, manual mode is recommended. (Sensitivity is fixed and does not automatically change.)

■ By pressing 【CM】, detection sensitivity increases to 3g / year. For normal detection, detect with standard mode and for detection with better sensitivity set the detection sensitivity to 3g / year.

■ By pressing 【LED light ON / OFF】, lights up. With the light, can detect for refrigerant leackages in internal system, ceiling, and basement easily.

Accurate leak detection with high -performance, high -sensitivity with infrared sensor(NDIR type), and 9 stages colour indicator.

INFRARED ( NDIR TYPE) LEAK DETECTOR

DIRECT INSPECTION

Image of Leakage

bleep! bleep!bleep! bleep!

DetectorLeakage

Defineleakingpoint

Stay Level of Indicator

Detect with Higher Sensitivity

Stay Level of Indicator Light LED lamps

184mm

70mm

Leak Detector LD316Infrared (NDIR type) leak detector

Code No.LD316E

Page 4: REFRIGERANT SERVICE TOOLS - asada.co.jp · Possible to detect a small leak of each ... Indicator displays the value of leak in 6 stages. ... REFRIGERANT SERVICE TOOLS System ...

GAS LEAKAG

E DETECTIO

N &

PREVEN

TION

MAN

IFOLD

S, CHAR

GIN

G H

OSES &

VALVESVACU

UM

PUM

PSR

EFRIG

ERAN

T SERVICE TO

OLS

38

Applicable refrigerantR410A, R407C, R404A, R507A, R134a, R12, R22, R500, R502, HFO1234yf, R32, R245fa, etc.

Detection method Heated semiconductor sensor

Gas Introduction method Gas suction system

Power 100V or AA alkaline battery

Weight 480g (include battery)

Temperature range working temperature : –4 ~52°C

Standard accessories100V AC adapter, AA alkaline battery×4, Sensor, Spare filter, Leak check bottle, Case

Leak level LED displays the amount of leakage by 9 stages !!

For refrigerant leak detection of large fridge– freezer・large A / C・commercial A /C・package A /C・room A /C・showcase・refrigerator・vending machine・car A /C.

Both AC /DC can be used.

Alarm is changeable. (ON /OFF)

Heated semiconductor sensor

■ When the heated sensing element is exposed to refrigerant, the electrochemical reaction changes the resistance within the element causing an alarm. Sensitivity will not decrease with exposure to dirt, oil, and water. Service life is more than 300 hours with minimal cleaning and no adjustments.

Bring closer the sensor unit to the piping to check. Search leakage position with the leak detection signal sound. Possible to detect a small leak of each type of refrigerant. Workable near electiricity with sensor typed Leak Detector !!

Sensor for Replacement (with filter) : Code No. Y69384Sensor Filter (5 PCS) :Code No. Y69385W

Repair part

Refrigerant R410A R407C R404ASensitivity / yr 1.7g 1.7g 1.7g

Refrigerant R507A R134a R12Sensitivity / yr 1.7g 1.7g 1.7g

Refrigerant R32 R245faSensitivity / yr 1.7g 20ppm

Refrigerant R22 R502 1234yfSensitivity / yr 0.9g 1.7g 4.3g

※ Sensitivity is the value that was approved based on Standard SAE J 1627 & SAE J 2791.

Measure of leak sensitivity

Refrigerant gas enters from here

Sensor element

Heater

Heater circuit

Resistance measurement circuit

Alarm circuit

UV Light

■ With high brightness UV LED Light, can detect the leakage of A /C containing fluorescent agent.

Flexible probe Flash LED

Sensor is replaceable

Leak level LED

Sensitivity 1.7g / year

■ Probe can be kept bent. ■ The more the concentration of the refrigerant gets higher, the more point deceleration gets faster.

■ Heated semiconductor sensor is replaceable by one action.

■ Digitally displays the leakage with 9 stages.

■ With high sensitivity of heat sensor, detects HFC refrigerant.

HEATED SEMICONDUCTOR SENSOR LEAK DETECTOR

265mm

65mm

DIRECT INSPECTION

R32applicable Freon HFO

1234yfUV light :High brightness UV LED 3(UV wavelength 405±10nm)

Heat semiconductor

sensor

Heated Sensor type Leak Detector (with UV light)

Heated semiconductor sensor leak detector

Code No.Y69338

Page 5: REFRIGERANT SERVICE TOOLS - asada.co.jp · Possible to detect a small leak of each ... Indicator displays the value of leak in 6 stages. ... REFRIGERANT SERVICE TOOLS System ...

GAS LEAKAG

E DETECTIO

N &

PREVEN

TION

MAN

IFOLD

S, CHAR

GIN

G H

OSES &

VALVESVACU

UM

PUM

PSR

EFRIG

ERAN

T SERVICE TO

OLS

39

Sensor for Combustible Gas : Code No. Y69371

Sensor for Gas Mate : Code No. LB706700

Repair part

Repair part

Gas detection of HC refrigeration storage room, gas pipe, gas heater, etc.Indicator displays the value of leak in 6 stages.Low battery LED Indicates when the battery needs to be replaced.Automatic calibration & zero setting.

Applicable refrigerantMethane, Isobutene, Propane, Methanol, Benzene, Ethan, Gasoline, Acetone, Butane, Acetylene, Toluene, Methyl alcohol, Ethylene, Ammonium, etc

Detecting method Electro chemical Sensitivity 15ppm (methane)

Power Alkaline battery×4 Weight 406g (includes battery)

Dimension L :65×W:52×H :264mm Temperature range 0 ~52°C

Standard accessories Sensor, Alkaline battery, Case

HC (flammable)Isobutane

High sensitive detection of combustible gas such as HC !

Gas detection of HC refrigeration storage room, gas pipe, gas heater, etcHydrocarbon gas and other gases can be detected with the advanced technologySensitive to 5ppm methaneAuto zero setting for ignoring background gas levels in test area

Applicable refrigerantMethane, Natural gas, Propane, Butane, Isobutene, Ammonium, Cyclopentane, Ethan, Ethanol, etc

Detecting method Semiconductor Sensitivity 5ppm (mathane)

Power1.5V Alkaline battery×2 (40 hours) Weight 700g (includes battery)

Dimension L :57× W:88× H :215mm Temperature range 0~ 45°C

Standard accessories Sensor, Alkaline battery×2, Case

HC (flammable)Isobutane

High sensitive detection of combustible gas such as HC!

264mm

65mm

215mm

57mm

For A / C with CO2, Hot water despenser

203mm

63mm

Display and buzz for sensitivity select and leak detection.Easy operation with one button for power, sensitivity select and zero adjustment.Infrared sensor lasts more than 2 years.

Applicable refrigerant CO2

Detecting method Infrared sensorGas introduction

methodGas suction system

Sensitivity Hi : under 400ppm Lo :4,000ppm (atmospheric concentration 350ppm)

Weight 425g (with battery) Power Alkaline battery

Temperature range 0~50°C Dimension L : 203×W: 63×H:57mm

Standard accessories Alkaline battery, Spare filter, Case

Hi:under 400ppm (atmospheric concentration 350ppm)Lo:under 4,000ppm (atmospheric concentration 350ppm)

CO2

Combustible gas

Combustible gas

Muting function

Muting function

Electrochemical method

Semiconductor sensor

Infraredsensor

CO2 Sensor : Code No.Y69398 Filter Kit (10pcs) : Code No.Y69397

Repair part

CO2 Leak DetectorInfrared (NDIR type) CO2 leak detector

Code No.Y69396

Combustible Gas DetectorLeak detector

Code No.Y69373

Gas MateCombustible gas detector

Code No.LB706600

Page 6: REFRIGERANT SERVICE TOOLS - asada.co.jp · Possible to detect a small leak of each ... Indicator displays the value of leak in 6 stages. ... REFRIGERANT SERVICE TOOLS System ...

GAS LEAKAG

E DETECTIO

N &

PREVEN

TION

MAN

IFOLD

S, CHAR

GIN

G H

OSES &

VALVESVACU

UM

PUM

PSR

EFRIG

ERAN

T SERVICE TO

OLS

40

Hose for Nitrogen

Hose for Nitrogen

Length Code No. Length Code No.10m XP415 30m XP40520m XP425 40m XP435

Length Code No. Length Code No.10m XP415 30m XP40520m XP425 40m XP435

Working pressure : 6.8MPaBurst pressure : 27.5MPa

Working pressure : 6.8MPaBurst pressure : 27.5MPa

Airtight test is necessary even a connecting looks perfect !!

With valve core

With valve core

1/4"1/4"

For removing moisture, foreign substances when plumbing.Flushing of existing pipes to be used when installing cleaning less A /C.

Eco friendly as biodegrading. Contains no chlorine. (less corrosive than deionized water) Large bubbles stay for long period to help detecting small leaks.Spreads all over the surface because of the water soluble adhesion.

For preventing refrigerant leakage.Pressure can be adjusted by a handle operation.

Nitrogen blow prevents copper tube from oxide film during brazing

Necessity of airtight test

Pressure Primary side :0~25MPa / Secondary side :0~2.5MPaSecondary adjustable pressure 0~ 1.0MPa

Hose Proof pressure :5.0MPa / Burst pressure : 20.0MPa

Standard accessoriesTaper nozzle large (1/2" • 5/8" • 3/4"),Taper nozzle small (1/4" • 3/8"),Ball valve,1/4" hose for nitrogen 3m (XP410), Regulator for nitrogen blow, Case

Pressure Primary side :0~25MPa / Secondary side :0~15MPaSecondary adjustable pressure 0~ 8.0MPa

Hose Proof pressure :6.8MPa / Burst pressure : 27.5MPa

Standard accessoriesRegulator for airtight test, 1/4" hose for nitrogen 3m×2, Pressure gauge with T cheese, ø80mm single manifold, Adapter for different diameter 1/4"×5/16", Case

※ Hose for nitrogen (XP410) is not applicable to airtight test.

Leakage prevention product

For airtight test of plumbing and various systems

■ Just spray Big Blu to pipings. Bubbles bulge and easy to find a leakage. Item 0.95L 3.8L for refill 0.95L (low temperature) 3.8L for refill (low temperature)

Code No. RT100S RT100G RT150S RT150GAmount 0.95L 3.8L 0.95L 3.8L

Temperature range 1.6~80°C − 34~94°C

3.8L For refill 3.8L For refill

For low temperature

0.95L 0.95L

NITROGEN BLOW KIT

AIRTIGHT TEST KIT

Code No.XP676

Code No.XP681

Nitrogen Blow Kit

Big Blu Big Blu for Low Temperature PAT.

Airtight Test Kit

For nitrogen gas shield pipes during brazing

Spray type gas leak detector

For airtight test of plumbing and various systems by nitrogen gas

No freeze at –34°C !! Applicable to refrigerators for food !!

■ Defective brazing or corrosion causes leakage accidents. For preventing these accidents, during brazing, use Nitrogen Blow Kit not to make oxide film inside the pipe.※ Applicable to not only brazing, but also to blowing before or after flushing existing pipes or various blow works.

Necessity of Nitrogen blowing

without nitrogen blow▶

oxide filmwith nitrogen blow

■ Even a connection looks perfect, it may leak from somewhere. To prevent leakage, “Airtight test” is required as a final inspection.

Combination of ASADA “Airtight Test Kit” with “Charge Clamp” realize more complete airtight test. ▶

Realize piping without leakage !

1/4"1/4"

1/4"

DIRECT DETECTION BUBBLING LIQUIDWorld No.1 sensitivity with spray type !!For checking leakages of refrigerant systems.

Page 7: REFRIGERANT SERVICE TOOLS - asada.co.jp · Possible to detect a small leak of each ... Indicator displays the value of leak in 6 stages. ... REFRIGERANT SERVICE TOOLS System ...

GAS LEAKAG

E DETECTIO

N &

PREVEN

TION

MAN

IFOLD

S, CHAR

GIN

G H

OSES &

VALVESVACU

UM

PUM

PSR

EFRIG

ERAN

T SERVICE TO

OLS

41

Even the places not directly visible, easy to find a leak location with an inspection camera.

■ Check the appearance of the entire system by auditory and sight. Search for the presence of frost & bleeding oil from various parts.

■ Search for the leakages with Service Mirror or inspection camera when checking the back of pipes or narrow areas.

Visual inspection of piping & inside system

Visual inspection of the hard - to - see place

Ideal for checking narrow or hidden areas.Stainless steel mirror with 360° rotatable ball joint.Extendable handle up to 700mm.

Ideal for checking narrow or hidden dark areas with LED light.Stainless steel mirror with 360°rotatable ball joint.Extendable handle up to 750mm.Button battery.

ø95mm

Mirror size : ø52mmHead thickness :10mm

Mirror size : 41×64mmHead thickness :10mm

RoundY78100

RoundMTIM30

SquareMTIM24

Square・SmallY78102

Square・LargeY78101

95×50mm

50×32mm

280mm ~ 865mm

(Includes Head part)

122mm

39mm

230mm

System leakage inspection

VISUAL APPEARANCE INSPECTION

Inspection camera.

BatteryLi -Polymer Battery (2hours charge for 4hours use) ※ Voltage made to order

Camera Head diameter : ø5.5mm

Camera cable length 1m

Display 3.5 TFT colour LCD /Resolution :320×240 pixel

Weight 450g (Body)

Saving formatImage • JPEG (300,000 pixels)Video • AVI (300,000 pixels)

Storage medium SD Card (Max. 32GB)

External output USB, AV

Standardaccessories

Clear scope, Clear scope cable, AC adapter, Mini USB cable, AV cable, SD card 2GB, Carrying case

285mm ~ 870mm(Includes Head part)

Service Mirror

Survice Mirror with LED Light

Clear Scope • Digital 100

Mirror for a detection

Mirror for a detection

For checking pipes, A/C, cars, etc

Round : Code No.Y78100 Square • Small : Code No.Y78101Square • Large : Code No.Y78102

Round :Code No.MTIM30 Square :Code No.MTIM24

Code No.TH100

Head diameter :5.5mm

2 ×Digital Zoom function

Image reversal function

Flexible Cable

Page 8: REFRIGERANT SERVICE TOOLS - asada.co.jp · Possible to detect a small leak of each ... Indicator displays the value of leak in 6 stages. ... REFRIGERANT SERVICE TOOLS System ...

GAS LEAKAG

E DETECTIO

N &

PREVEN

TION

MAN

IFOLD

S, CHAR

GIN

G H

OSES &

VALVESVACU

UM

PUM

PSR

EFRIG

ERAN

T SERVICE TO

OLS

42

REFRIGERANT " LEAK-FREE " SEAL

FLARETITE

Many cases of refrigerants leak from flare fittings. If use Flaretite when installation and maintenance of refrigeration equipment, it prevents refrigerant leakage from flare fittings.

To seal flare fitting in room, packaged & industrial air conditioner, freezer, refrigerator and showcase, etc.For service port, expansion valve, filter dryer, ball valve, solenoid valve, pressure & temperature regulator and branch pipe, etc.

Structure of Flaretite & Flaretite Cu Easy installation Quick repair

Applicable to all kinds of refrigerant & refrigeration oil

Flaretite❶ Loctite sealant❷ Stepped copper gasket❸ Patented tab

Flaretite Cu❶ Stepped copper gasket (material : C1220 permissible substitute)

❷ Patent–Clip function

❶ ❶

❷ ❷❸

■ Flaretite has been used for more than 5 years by major refregiration equipment manufacturer.■ Flaretite has attracted a public attention in California where the regregerant leakage is serious problem as it prevents refrigrant leakage from flare.

Patented tabs hold the seal in place and support easy installation.

Quick & easy repair for leakage from flare fitting.Save time & cost for repair.

Refrigerant leakage test with damaged flare joint

〈 Test condition 〉

Test result with Flaretite

The secret of Flaretite to prevent leakageFlared copper tube

Flaresurface

Flare surface

Coating (Loctite)

Base material(metal) (drawing)

Sealing for dent and scratch

Flare seal point

Correct an error of flare angle

Test result without Flaretite

Leakageat

2MPa

Leakageat

2MPa

3 hoursafterchargednitrogen

Date / 2011.12.9

Copper tube size1/4”

Room temperature during test17°C

Tightening torque16N • m

Pressure testNitrogen gas 5MPa

Disrepairscratch toward axis direction

Flare surface ofcopper tube

Flare surface ofmale flare

ScratchScratch

ScratchScratch

5MPa

No leakagewith

scratch

5MPa

No leakagewith

scratch

Sealant fills scratchfills scratchon the flare and preventsleakage.

Seal - ring adheres to flare surfaceby pressing and.

effective for maximum 1 degree error.

Prevent refrigerant leakage from flare fittings

■ Patented seal coated Loctite sealant.■ Prevent leakage with stepped copper gasket.

■ Coated Loctite sealant.■ Special technology not to mix the sealant in the system.

■ You can use your torque wrench to tighten.■ Just snap the Flaretite onto the end of male flare.

Prevent refrigerant leakage during operation

Stepped sealant

Easy installationConventional

tightening torque

OK!!

Snap–easily

Page 9: REFRIGERANT SERVICE TOOLS - asada.co.jp · Possible to detect a small leak of each ... Indicator displays the value of leak in 6 stages. ... REFRIGERANT SERVICE TOOLS System ...

GAS LEAKAG

E DETECTIO

N &

PREVEN

TION

MAN

IFOLD

S, CHAR

GIN

G H

OSES &

VALVESVACU

UM

PUM

PSR

EFRIG

ERAN

T SERVICE TO

OLS

43

Item Code No. QTY.

Flaretite

1/4" (10pcs) FT0414 1

3/8" (10pcs) FT0638 1

1/2" (10pcs) FT0812 1

5/8" (10pcs) FT1058 1

3/4" (10pcs) FT1234 1

Trial 5 sizes set (each 2pcs :10pcs) FT054 1

1/4" • 3/8" set (each 5pcs :10pcs) FT061 1

1/4" • 1/2" set (each 5pcs :10pcs) FT062 1

3/8" • 5/8" set (each 5pcs :10pcs) FT063 1

3/8" • 3/4" set (each 5pcs :10pcs) FT064 1

1/4" (100pcs) FT04140 1

3/8" (100pcs) FT06380 1

1/2" (100pcs) FT08120 1

5/8" (100pcs) FT10580 1

3/4" (100pcs) FT12340 1

All 5 sizes set (※) (100pcs) FT065 1

※ 1/4" • 3/8" • 1/2" • 5/8" • 3/4"×each 20pcs. (Total 100 pcs)

Item Code No. QTY

Flaretite Cu

1/4" (10pcs) FT0414N 1

3/8" (10pcs) FT0638N 1

1/2" (10pcs) FT0812N 1

5/8" (10pcs) FT1058N 1

3/4" (10pcs) FT1234N 1

1/4" (100pcs) FT04140N 1

3/8" (100pcs) FT06380N 1

1/2" (100pcs) FT08120N 1

5/8" (100pcs) FT10580N 1

3/4" (100pcs) FT12340N 1

10 pcs

All 5 sizes set (※)

100 pcs

For preventing leakage from filters and an expansion valve of HVAC equipment or installation of pipes !!

For repairing of filters, maintenance, and an expansion valve of existing HVAC equipment !!

Prevernt even large leakage by the Loctite sealant and the stepped copper gasket.Loctite sealant protects the face of fitting from over- tightening.

Prevent very small leaks that cannot be determined in airtight test with a stepped copper gasket. Stepped shape prevents leakages due to a slippage of the angle or center.

Its flexibility allows to be used for various flare couplers.For flare couplers by copper, applicable to any fluid.

Loctite sealant fills scratch on the flare and prevents leakage.

Loctite sealant

Patent stepped copper gasket Flexible copper packing

For scratch on the flare

Loctite (No.517) does not harm refrigerant equipment due to inert substance.

Enter the scratch

Loctite sealant

More than

ofexperience!!5 years

More than

ofexperience!!10 years

Flaretite PAT.

Flaretite Cu PAT.

Refrigerant "Leak - Free" seal

Refrigerant "Leak - Free" seal

Stepped copper gasket with patented tab. (※)Copper seal is suitable for various flare fitting.Rated for all common gases and fluids.Applicable to angle gap of flare and gap between center of pipes.

10 pcs 100 pcs

Page 10: REFRIGERANT SERVICE TOOLS - asada.co.jp · Possible to detect a small leak of each ... Indicator displays the value of leak in 6 stages. ... REFRIGERANT SERVICE TOOLS System ...

GAS LEAKAG

E DETECTIO

N &

PREVEN

TION

MAN

IFOLD

S, CHAR

GIN

G H

OSES &

VALVESVACU

UM

PUM

PSR

EFRIG

ERAN

T SERVICE TO

OLS

44

LOCTITE AngleSize

1/8" 1/4" 3/8" 1/2" 5/8" 3/4" 7/8" 1" 1~1/4" 1 ~1/2" 2"

1701537° 316 316 316 316 316 316 316 316 316 316 316

37° Cu Cu Cu Cu Cu Cu Cu Cu Cu − −

Rated for – 40~648°C, JIC 37° flare

LOCTITE AngleSize

1/8" 1/4" 3/8" 1/2" 5/8" 3/4" 7/8" 1" 1~1/4" 1 ~1/2" 2"

−37° 316 316 316 316 316 316 316 316 − − −

45° − 316 316 316 316 316 − − − − −

Rated for all temperature, acceptable for radoation environments, JIC 37° flare, SAE 45° flare

LOCTITE AngleSize

1/8" 1/4" 3/8" 1/2" 5/8" 3/4" 7/8" 1" 1~1/4" 1 ~1/2" 2"

517

37° 316 316 316 316 316 316 316 316 316 316 316

45° − 316 316 316 316 316 − − − − −

45° − Cu Cu Cu Cu Cu − − − − −

Rated for – 40~148°C, JIC 37° flare, SAE45° flare

Leak prevention from flare, valve opener,gasket, screw and O-ring.

LOCTITE AngleSize

1/8" 1/4" 3/8" 1/2" 5/8" 3/4" 7/8" 1" 1~1/4" 1 ~1/2" 2"

517 37° − 304 304 304 304 304 − 304 304 − −

Rated for – 40~148°C, JIC 37° flare

LOCTITE AngleSize

1/8" 1/4" 3/8" 1/2" 5/8" 3/4" 7/8" 1" 1~1/4" 1 ~1/2" 2"

− 37° − 304 304 304 304 304 − 304 304 − −

Rated for all temperatures, JIC 37° flare

LOCTITE Angle1/4" 3/8" 1/2" 5/8" 3/4"

517 37° Cu Cu Cu Cu Cu

Rated for – 40~148°C, JIC 37° flare

For leak prevention from flare fitting of Hydraulic • Fuel • Gases.(JIC 37° flare • SAE 45° flare)

For leak prevention from plubming and connecting part of hose of Hydraulic equipment, Garbage truck, Construction machine, Press machine, Injection moulding machine.

Same technology as refrigeration seals prevents all common gas and fluiad leakage from flare fitting !

Various type of seals for various flare fittings,gases & fluids and environment !

For flare For valve opener For gasket

Standard carbon steel seals 304 Stainless steel seal with Loctite Vibra Seal coating

Special application seals 304 Stainless steel seal without coating

Refrigeration seals Copper seal with standard loctite Vibra seal coating

Nuclear power seals 316 Stainles steel seal without coating

High temp. oil and stea seals 316 Stainless steel seal with Loctite high temp graphite coating

Marine and corrosive environment seals 316 Stainless steel seal with Loctite Vibra Seal coating

Flaretite for general flare fitting (For all common gases and fluids) PAT.

"Leak - Free" seal

Back order

Does not harm system as the component of Nylog is refrigeration oil.Nylog blue for sealing flare surface under high pressure of new type regrigerant.Prevents troubles due to the leak of HFC refrigerant.

Item Nylog blue Nylog red

Applicable refrigerant HFC refrigerant CFC • HCFC refrigerant

Working temperature −37°C~210°C −34°C~ 175°C

Capacity 30mL 30mL

Quantity in box 12 12

Nylog PAT.

Gas leak preventing sealant

Blue : Code No.RT201B Red : Code No.RT200R

HFC Nylog blue CFC HCFC Nylog red