Sr. No.
Reference to Invitation of budgetary quote Queries DGLL Reply
Page Clause Description
M/s Elcome Integrated Pvt. Ltd
1. 3 Organizational structure
It would be pertinent to know what kind of eligibility would a tender like NCVTS would demand. This would help us align the required partnership. This is important to provide any meaningful prices, since it would be jointly decided by partners and partners would be decided based on eligibility and qualification criteria.
The eligibility criteria like experience, valid MoU among partners etc. will be based on the prevailing Govt. guidelines.
2. 4 Appendix – 2
3. 10 2.1.1 NCVTS – System architecture
As per this clause data from sensors would be sent to DACs. However as per clause 1.6.1, mentions the following: “The state VTS control would integrate feed from various equipment installed at VTS sites. Please clarify the connectivity between VTS sites, DACs, SMCs, existing infrastructure.
The “State VTS Control” may be read as “State Monitor”. This issues addressed in new network architecture placed at Annexure 1.
4. 11 2.1.4 (d) Radio Communication (VHF) sets
VHFs installed at DACs would have limited use since the range would be limited. We feed instead of VHFs, VHF operator stations should be provided which can be used by the VTS operator to communicate with the ship using the VHF installed at Radar Station. We feel more than one VHF would be required at the Radar station.
VHFs would be at RS and PMS. All other stations to have VHF operator panels / stations. BOM is suitably revised and placed at Annexure 2.
5. 12 2.1.5 (d) Radio Communication (VHF) sets
VHFs installed at SMCs would have limited use since the range would be limited. We feed instead of VHFs, VHF operator stations should be provided which can be used by the VTS operator to communicate with the ship using the VHF installed at Radar Station.
VHFs would be at RS and PMS. All other stations to have VHF operator panels / stations. BOM is suitably revised and placed at Annexure 2.
Sr. No.
Reference to Invitation of budgetary quote Queries DGLL Reply
Page Clause Description
6. 11 & 12
2.1.4 & 2.1.5
List of equipment
In the list of equipment provided, there is no link requested between DAC & SMC.
See network architecture at Annexure 1
7. 2.1.7 List of equipment
In the list of equipment provided, there is no link requested between CMC & NMC.
See network architecture at Annexure 1
8. 13 2.1.8 List of equipment
i. To whom will PMC connect and how.
ii. Depending on the answer to above question, the PMC may not
require processing server, but just console for monitoring.
See network architecture at Annexure 1
9. 16 2.2.5 (b)
Microwave link / VSAT / Leased Line (as per suitability) for Data transfer among Radar Stations and between Radar Stations & PMS.
i. Is PMS same as PMC?
ii. Does this mean PMC connect directly to Radar stations?
i. Yes
ii. See network
architecture at
Annexure 1
10. General The connectivity between various sites may please be revisited for optimization and better performance of the system.
See network architecture at Annexure 1
11. 17 2.2.7 DSC: Built-in class D DSC
Please note that Class D DSC is for leisure boats. Further, DSC is the responsibility of MRCC which in case of India is Indian Coast Guard. We request that the requirement of DSC be deleted.
Full DSC functionality is to be provided.
12. 23 2.2.17
The camera shall be installed at control tower
Where is the camera installed, at PMC as per this clause or at Radar station (as per 2.1.2 (e)).
Camera would be installed at selected Radar Stations catering to PMS.
Sr. No.
Reference to Invitation of budgetary quote Queries DGLL Reply
Page Clause Description
M/s Kongsberg
13. 1
Submission on 20th December 2016
Please allow minimum 4 weeks preparation time for the parties to respond after the pre-bid replies has been distributed.
Considering the request from all bidders, submission date is revised to 27th January 2017.
14. 7 1.5 d Equipment - Manufacturer
Not updated information
Request to Update table with correct manufacturers and year of installation
Updated data placed at Annexure 3.
15. 7 1.6.1
Raw data feed from Static Sensors of Indian Coast Guard
Have the security risk been addressed with regards to reveal sensitive information
Considering the security risk, we suggest not to integrate the Coast Guard radar system with National VTS
Requirement prevails.
16. 9 1.10 Mid - life upgrade
Where in BoQ shall this cost be included
Kindly clarify
Midlife upgrade to be included as part of CAMC.
17. 9 1.10
The entire system shall be upgraded for IT products….
Please define IT products
Other equipment than computer equipment will have limited life span
All IT equipment like:
Computers, Servers, Switches, Routers, Storage, UPS, Monitors and all such items where the OEM has declared end of support.
Sr. No.
Reference to Invitation of budgetary quote Queries DGLL Reply
Page Clause Description
18. 14 2.2.2 ASTERIX format
Why ASTERIX format?
IVEF format will suffice
ASTERIX format will be applicable for radar video feed.
19. 22 2.2.17 CCTV System Please clarify performance requirements of the CCTV system
300 GRT vessel to be detected at 10 Nm. “CCTV” be read as “Long Range Optic Camera” .
20. 26 2.2.30 (a)
128 bit architecture
Any particular reason for this requirement
Suggest to delete this requirement
128 bit to be read as 64 bit.
21. 26 2.2.30 (g & i)
DAT drives/ High Speed back tape drive system
Why is this media required Storage to be by way of NAS with RAID5.
22. 26 2.2.30 (j)
Operating System UNIX/ LINUX
Why is only UNIX/ LINUX operating system required?
We suggest any reputed operating system should also be allowed.
Windows is acceptable provided it is suitably protected against hacks, attacks and is secured.
23. 30
Bill of Material, No. A (1)
Provision for circular polarization
Inconsistency with clause 2.1.1 (iii)
We suggest including both polarizations to meet performance requirements. The word ‘provision’ should be replaced with ‘switchable’.
Requirement is for switchable horizontal and circular polarization.
24. 31
Bill of Material, No. F (1)
Camera System
Inconsistency with CCTV requirements given in sec 2.2.17
Please clarify your requirement
Please see reply at serial no. 19 above.
25. BoQ All Please clarify quantities Updated BOM placed at Annexure 2
Sr. No.
Reference to Invitation of budgetary quote Queries DGLL Reply
Page Clause Description
M/s RDS
26. 7 1.7.1
Any outdated equipment of OEM should be replaced with latest version/model”
Is that valid as well for the equipment of the AIS network which is reused?
No.
27. 8 1.7.2 a)
Radar equipment (existing and new)
Please provide details of existing radars which is to be integrated also with location and site address a. make & Model b. Data output format c. Year of manufacturing
Updated data placed at Annexure 3.
28. 8 1.7.2 d) AIS System (existing and new)
Please provide details of existing AIS which is to be integrated a. make & Model b. Data output format c. Year of manufacturing
Data would be provided
as a single TCP/IP
stream AIVDM message
at DAC level.
Sr. No.
Reference to Invitation of budgetary quote Queries DGLL Reply
Page Clause Description
29. 8 1.8.b
Provision to meet operational requirements i) IALA Guideline No. 1110 ii) IALA Guideline No. 1111 iii) IALA Guideline No. 1070
Please clarify if the VHF communication system shall comply to IALA Guideline No. 1111?
Yes
Sr. No.
Reference to Invitation of budgetary quote Queries DGLL Reply
Page Clause Description
30. 9 1.90
The NCVTS will be a complex system having number of different hardware and software modules, integration of existing systems viz. communication network of NAIS, raw data from radars of CSN network, VTS at major ports, AIS feed from NAIS network etc. Necessary Provisions to be made in the NCVTS system to interface with ERP/MIS system in the ports in the future
With respect to the integration of the existing VTS systems: Is there any information available which interfaces the different systems provide (e.g. IVEF-interface, ASTERIX CAT240 for radar video, etc.)?
To be explored by the
agency.
Sr. No.
Reference to Invitation of budgetary quote Queries DGLL Reply
Page Clause Description
31. 9 1.10
System Up-gradation The NCVTS shall be designed with a view for future growth. Up to integration of new VTS sites/sensors and work stations. The entire system shall be upgraded for IT products, and software, as midlife upgrade after 5 yrs
What is exactly mean by mid-life upgrade? Do we need to consider replacement of hardware or upgrade the software part? Request to elaborate the same. Do we have to calculate the costs of the midlife upgrade of IT HW and software within this price item?
Please see reply at
serial 17 above.
32. 9 1.11
Maintenance There should be adequate trained manpower available for maintenance of the system on 24 x 365 hours
Please confirm at how many location we need to consider maintenance manpower.
DAC and NMC.
Sr. No.
Reference to Invitation of budgetary quote Queries DGLL Reply
Page Clause Description
33. 11 & 12
2.1.4 (d) / 2.1.5 (d)
Radio Communication (VHF) sets
Is there any requirement of standalone VHF or need to be considered remotely operated VHF
Remotely operated
VHF.
34. 11,12 & 13
2.1.4 (f) / 2.1.5 (f) / 2.1.6 (e) / 2.1.7 (f) / 2.1.8 (f)
Air conditioners/Furniture, electricity, back-up power (UPS & Gen-Set), net connectivity, back office support, ancillary equipment etc.
Please confirm the quantity and specs regarding items like AC's, UPS, Genset
All generic specs have
already been provided
in our document, bidder
to use the same and
their experience and
provide the best
solution.
35. 12 2.1.7
The data will be shared to external stakeholders like Indian navy, Indian Coast Guard, BSF, Marine Police, IPA, etc. from National Monitoring Centre.
Are there any requirements concerning the interfaces to external stakeholders
A complete operator
terminal to be provided
to these external
stakeholders through
leased line.
Sr. No.
Reference to Invitation of budgetary quote Queries DGLL Reply
Page Clause Description
36. 13 2.2.1 (vii)
RADAR Transceiver Frequency Diversity
Is the requirement is of frequency diversity or frequency redundant
Radar to have frequency diversity. Dual radar transceivers are required for redundancy operating in hot standby mode.
37. 14 2.2.2
Should be able to export data under IVEF (Inter VTS Exchange Format).
ASTERIX is asked for video only. Please clarify if also tracking data shall be compatible with ASTERIX format and specify the ASTERIX categories that shall be supported
Yes, ASTERIX is for
video only.
38. 15 2.2.5 (a)
Existing NAIS network is to be used for data transfer. Necessary hardware, software interface is to be provided.
How much is the bandwidth of existing NAIS network at each location. Also confirm the number of ports available in router / switch with make & model of router & switch.
Updated system architecture placed at Annexure 1
Sr. No.
Reference to Invitation of budgetary quote Queries DGLL Reply
Page Clause Description
39. 15 2.2.5 (b)
Microwave link/VSAT/Leased Line (as per suitability) for Data transfer among Radar Stations and between Radar Stations & PMS.
Kindly confirm the locations / addresses of proposed PMS and nearby radar station, accordingly media of network can be finalized.
Refer to Annexure 4
40. 15 2.2.5 (c)
Leased line (LL) connectivity for data transfer between PMS & respective State Control Centre.
Kindly confirm the locations / addresses of proposed PMS and SMCC, accordingly media of network can be finalized.
Refer to Annexure 4
Sr. No.
Reference to Invitation of budgetary quote Queries DGLL Reply
Page Clause Description
41. 15 2.2.5 (d)
Leased Line network for transfer of data for monitor terminals for security agencies (IN, ICG, BSF & State Marine Police) and for DG (Shipping), Mumbai.
Kindly confirm the locations / addresses of proposed IN, ICG, BSF & State Marine Police, accordingly media of network can be finalized.
Updated system architecture placed at Annexure 1. Media shall be lease line for external users.
42. 22 2.2.17. CCTV SYSTEM
Are there any performance requirements on the Cameras to be provided? Especially this might be a cost issue, as the range of camera models and prices is very wide
Please see reply at serial no. 19 above.
43. 24 2.2.18
Radar control functions like switching, PRF / Polarization, pulse width etc
Radar system: Is intended to be able to switch the polarization of the radar
Please see reply at
serial no. 23 above.
Sr. No.
Reference to Invitation of budgetary quote Queries DGLL Reply
Page Clause Description
44. 26 2.2.29
AIS MESSAGING The console should enable the VTS operator to send AIS messages to specific vessels using their MMSI number and also broadcast to all ships
Capability of sending AIS Messages is required. Please specify the interface used towards the NAIS.
Yes. Interface to be
decided during detailed
system engineering
which shall be carried
out with the successful
bidder.
45. 26 2.2.31 WAN/LAN
Are there any additional information about the scope of work for the network of the system? The information provided on the requested VSAT-System as well as for the leased lines is not clear & requests elaborate the same.
Updated system architecture placed at Annexure 1.
M/s Rolta
46. 4
Experience
for supply and
installation of
Vessel Traffic
System
The experience of Partners/JV partners should be included. Please see reply at serial 1 above.
47. 6 1.5
Existing
VTMS
systems
Integration points are to be specified in order to determine
networking requirement
Integration point shall be the DAC centre for each existing VTMS system.
Sr. No.
Reference to Invitation of budgetary quote Queries DGLL Reply
Page Clause Description
48. 7 1.5(d)
Existing
VTMS
systems
Existing system include systems with both Windows based and
Linux based OS.
Please give Interface / protocol information of these existing
systems
The interface will be TCP/IP and thus independent of the operating system. Interface to existing system shall be in any of the following two methods:
i. Direct interface to
radar analogue data
ii. IVEF.
49. 8 1.7.2(k)
Existing NAIS
network to be
used for data
transfer.
Existing NAIS
may not have
the required
bandwidth.
Please specify approximate bandwidth required for data transfer. Updated system architecture placed at Annexure 1.
50. 9 1.12
Provision to
extend
NCVTS feed
to various
agencies
Please provide location of these Offices / integration points Data provided at Annexure 4.
Sr. No.
Reference to Invitation of budgetary quote Queries DGLL Reply
Page Clause Description
51. 9 1.9
Integration
with existing
systems such
as NAIS,
radars of CSN
network, VTS
of Ports etc.
Integration points are to be specified in order to determine
networking requirement Data provided at Annexure 4.
52. 9 1.9
Necessary
provisions to
be made to
interface with
ERP/MIS
system of
Ports in
future.
Please elaborate the scope
Data is to be provided to
existing ERP/MIS from
VTS. This would be
primarily as a TCP/IP
one way interface where
data about VTS events
is sent to ERP/MIS. The
exact contents of the
data cannot be
determined at this
stage, bidder to
provision flexibility of
creating suitable outputs
to ERP/MIS.
53. 9 1.11 Maintenance We understand that CAMC will start after Warranty. Please confirm
the requirement of no of years of Warranty to be considered. Warranty is one year and CAMC is 9 years.
Sr. No.
Reference to Invitation of budgetary quote Queries DGLL Reply
Page Clause Description
54.
11,
12 &
13
2.1.4,
2.1.5,
2.1.6,
2.1.7,
2.1.8
DBMS
Servers &
Processing
servers with
Software
(With
redundancy)
Qty 1
Are we expected to provide redundancy for servers with Qty1 or
2?? Server with hot stand by (1:1)
55.
11 2.1.3
DACs will be
established at
the respective
Deep
Bhavans
Are all these Deep Bhavans connected with the NAIS network?
Yes, except at Goa and Bhubaneswar. Please see revised system architecture at annexure 1.
56. 13 2.2.1 Radar Please provide location of proposed radars and existing radars of
CSN network Data provided at Annexure 4.
57. 13 2.2.1
Towers and
Civil works
for Radars
Please clarify whether Towers and civil works for the towers are
part of this scope. If so, please give Tower design and Foundation
requirement.
Towers and civil works are beyond the scope of this budgetary quote.
58. 16 2.2.6(g)
Creation of
Comprehensi
ve traffic
situation over
ECDIS
Is ECDIS part of this proposal?
If yes, how many numbers?
Please read ECDIS as ENC.
Sr. No.
Reference to Invitation of budgetary quote Queries DGLL Reply
Page Clause Description
59. 16 2.2.4
Electrical
infrastructure
(40KVA DG)
Please clarify type of the DG and Air cooled or water cooled type Air cooled.
60. 16 2.2.6(h) Simulation &
Training Please specify the scope of the Simulator
Simulator to provide capability of simulating various traffic situations for imparting training to operators.
61. 22 2.2.17 CCTV system
(a) Please clarify whether Towers and civil works for the
towers are part of this scope. If so, please give Tower
design and Foundation requirement.
(b) Please provide location of CCTV Cameras
(a) Towers and civil
works are beyond
the scope of this
budgetary quote.
(b) At selected radar stations, please see updated BOM at Annexure 2.
62. 26 2.2.30(j)
NCVTS
Computer
system OS
Can we propose Windows based Please see reply at serial 22 above.
63. 30 A 2,3 VTS Radar Pease provide location of 168 Radar Data Processors and 84
Display Units Data provided at Annexure 4.
64. 31 D VTS DATA
Feed Please give details of 100 feed locations
Provision to be made, the exact user list would be derived during project execution.
Sr. No.
Reference to Invitation of budgetary quote Queries DGLL Reply
Page Clause Description
65. 31 E1 VHF system
with VOIP Please give details of 346 locations
All RS & PMS. Location details provided at annexure 4.
66. 31 E2
VHF
SERVER
WITH Record
and Replay
Please give details of 18 locations All DACs. Location details provided at annexure 4.
67. 31 F1
Thermal
Camera
Sensor
Please give details of 30 locations
Selected radar stations catering to PMS. See system architecture at annexure 1.
68. 31 H
VTS software,
networking
and hardware
with Linux
base
Operating
System
Window Based OS should also be considered. Please see reply at serial 22 above.
69. 31 I 1 VSAT What is the Band with proposed for VSAT Bidder to suggest based on his design philosophy.
70. 1 Last date of submission is 20 Dec 2016
Date to be extended by 03 weeks after receipt of pre-bid clarifications
Please see reply at serial 13 above.
M/S Transas Marine India
Sr. No.
Reference to Invitation of budgetary quote Queries DGLL Reply
Page Clause Description
71. 1.3
(a) Information Service* (INS) A service to ensure that essential information becomes available in time for on- board decision-making.
Is information to be transmitted to vessels? And what will be this information?
Please refer IALA VTS Manual 2016.
Sr. No.
Reference to Invitation of budgetary quote Queries DGLL Reply
Page Clause Description
72. 1.9
Integration of existing systems viz. communication network of NAIS, raw data from radars of CSN network, VTS at major ports, AIS feed from NAIS network etc. Necessary Provisions to be made in the NCVTS system to interface with ERP/MIS system in the ports in the future
Format of data feed required to be integrated with NCVTS? Please see reply at serial 42 above.
Sr. No.
Reference to Invitation of budgetary quote Queries DGLL Reply
Page Clause Description
73. 1.10
System Up-gradation The NCVTS shall be designed with a view for future growth. Up to integration of new VTS sites/sensors and work stations. The entire system shall be upgraded for IT products, and software, as midlife upgrade after 5 yrs.
Scope of growth in %age? Should all IT HW be upgraded or only core components?
Refer Bill of material at Annexure 2.
As regards definition of IT products, please see reply at serial 17 above.
74. 2.1.4 Data Aggregation Centre
How many numbers? Please see updated system architecture at annexure 1
75. 2.1.5 State Monitor Centers (SMC)
How many numbers? Please see updated system architecture at annexure 1
Sr. No.
Reference to Invitation of budgetary quote Queries DGLL Reply
Page Clause Description
76. 2.2.1 Radar Specs
Should Radar comply with IALA Advanced or Standard? Recommended 18' antenna based Solid State Freq diversity Radar with dual X & S band capability. Output power is recommended to be min. 200W or above for better detection for ranges over 9 Nm. Dual transceiver is not so important for SS Radars as most have MTBF rate of over 10 years.
Radar should comply IALA Advanced specifications. Dual transceiver is opted as the Radar operates continuously for 24x7days and to provide redundancy in operation.
77. 2.2.3
(a) Existing NAIS network is to be used for data transfer. Necessary hardware, software interface is to be provided.
Pls advise format of data available from NAIS stations. Please see reply at serial 28 above.
78. 2.2.3
Data Networking - LL/Fiber connectivity
DGLL shall arrange for lease line / fiber as necessary. Vendor shall provide recommendations after pre-survey.
Entire Data networking and linking would be carried out by the vendor.
79. 2.2.6
(g) Creation of Comprehensive picture traffic situation over ECDIS
Pls elaborate. Please read ECDIS as ENC.
Sr. No.
Reference to Invitation of budgetary quote Queries DGLL Reply
Page Clause Description
80. 2.2.17 CCTV Camera - Day & Night
Is thermal imaging camera required? Yes.
M/s Consilium Marine India Private Ltd
81. 2.2.1
Transceiver Pulse compression Ration better than 500:1
Radar complying to mentioned pulse compression ratio has some restriction on export policy and is limited to PC of 150:1 kindly confirm the limit acceptable
Tender requirement stands.
82.
Transceiver frequency Diversity
Since most of the VTS application radar are of single frequency and this requirement is well confirming to IALA. Kindly confirm the requirement of frequency diversity
Frequency diversity is required.
M/s Sai Samarth, Mumbai
83. C2 Bill of Material Existing VTS providing IVEF data for Integration Yes most the existing VTS s are having IVEF output data format
84. F1 G1 Bill of Material Why quantity only 30, only state owned non major Ports Please see revised BOM at Annexure 2.
85. 2.1.2C Radio communication Set
VHF 1or 3 02 nos VHF sets are required at al radar stations and PMCs
86. 2.1.2D AIS unit NAIS AIS can support 1 more session to provide open format stream for integration
Yes
87. Expected hours of power availability in case Generator requires diesel tank
Power availability varies location to locations
Sr. No.
Reference to Invitation of budgetary quote Queries DGLL Reply
Page Clause Description
88. Tower requirement
Separate Tower will be constructed however same beyond scope this Budgetary quote
89. Radar and other site is it manned 24hrs Yes
90. 2.2.17 CCTV No specification of CCTV defined Please see reply at serial no. 19 above.
91. A2 BOM Radar quantity 45 why radar data processor 168 Please see revised BOM at Annexure 2.
92. A3 BOM Radar display unit quantity 84 which location Please see revised BOM at Annexure 2.
93. D BOM External agency only 100 feed supporting capability provision Please see reply at serial 35 above.
94. E2 BOM VHF recording quantity 18 location DAC1:1
VHF recording facility at all 9 DAC, Please see revised BOM at annexure 2
95. No VHF NMC BOQ
YES however provision of remote utilization of VHF installed at Radar station
96. No VHF in PMC 2 VHF set at each PMC
97. E1 BOM VHF system with VoIP , Qty 346 Please see revised BOM at Annexure 2.
98. H BOM Why mentioned as LINUX base operating system when this is not IALA requirement? Believe all OS meeting requirement?
Please see reply at serial 22 above.
Sr. No.
Reference to Invitation of budgetary quote Queries DGLL Reply
Page Clause Description
99. H4 BOM DBMS server, Data processing server 1:1 redundant Qty 26 Please see revised BOM at Annexure 2.
100. H6 Record and replay system to be installed at all Processor Qty 213? Please see revised BOM at Annexure 2.
101. I-1 BOM Why defined as PAMA? Believe any shared Access Technology meeting requirement is fine?
As tender documents
102. I-4 BOM 8 Mbps LL DAC to CMC qty 8, if 9 DAC and to connect to both CMC requires 18 or minimum 9 LL & 9 VSAT.
Please see revised system architecture at Annexure 1.
103. I-5 BOM 8 Mbps LL CMC to NMC Qty 2? Redundancy VSAT link? But as per design requirement 4 LL? + VSAT
Please see revised system architecture at Annexure 1.
104. J-2 BOM 55 PC with printer and internet connection Please see revised BOM at Annexure 2.
105. L-3 BOM 6 KVA UPS QTY-87? Locations Please see revised BOM at Annexure 2.
106. L-4 BOM 20 KVA UPS , locations Please see revised BOM at Annexure 2.
107. L-5 BOM 10 KVA UPS, locations Please see revised BOM at Annexure 2.
108. L-9 BOM 1.5 Tons Split AC locations Please see revised BOM at Annexure 2.
109. 2.2.17 BOM don’t reflect CCTV 36” requirements in PMC Please see revised BOM at Annexure 2.
M/s Aatash Norcontrol
Sr. No.
Reference to Invitation of budgetary quote Queries DGLL Reply
Page Clause Description
110. 6 1.5 C
…….Repeater Stations (Alang and Bhavnagar).
VTS Fee is applicable to all vessels plying
to Gulf of Khambhat.
In place of Bhavnagar, it should be Bhagwa and VTS Fee is also being collected by GMB Ports in Gulf of Kutch which is not mentioned in clause no. 1.5 (b).
“Bhavnagar” in clause 1.5 may be read as “”Bhagwa”
Sr. No.
Reference to Invitation of budgetary quote Queries DGLL Reply
Page Clause Description
111. 7
Cl no. 1.5 (d) SI. No. 5 Si. No. 6 Si. No. 7 Sl. No. 8 SI. No. 10 S1. No. 11 SI. No.12 SI no. 13 Sl. No. 10 SI. No. 12
Equipment – GEM Equipment - STN Equipment - Raytheon Equipment - Vissim Equipment - Transas Equipment - Raytheon Equipment - GEM
Equipment - Kongsberg Year of Installation-2016 Year of Installation-1996
According to us, it should be Litton According to us, it should be GEM According to us, it should be GEM According to us, it should be GEM According to us, it should be Selesmar According to us, it should be GEM According to us, it should be Selesmar According to us, it should be Selesmar According to us, it should be 2008 According to us, it should be 2014
Please see Annexure 3.
Sr. No.
Reference to Invitation of budgetary quote Queries DGLL Reply
Page Clause Description
112. 7
1.5, Sl.no.3
Location Mumbai High (ONGC)
Do we have to integrate this offshore radar as well Please see revised list at Annexure 3.
113. 7
1
.
6
.
1
……Static
sensors of
Indian Coast
Guard….
Para stands.
114. 9
1.10 ….. new VTS sites/sensors……
Kindly let us know Which, where and how many such new VTS
sites are going to be Included to provide more accurate
budgetary
quote
Please see Annexure 4.
115. 9
1.10 The entire system shall be upgraded for IT products……
' The metrological and hydrological sensors also have a
short span of life like 5 years. Whether those sensors should be considered for mid-life ' upgradation?
Hydro Sensors are not the part of NCVTS. Up-gradation of Mateo sensors is required
116. 10
2.1.1 System architecture of NCVTS - block diagram
According to the system architecture, we strongly feel that the latency will Increase at great extent w hich will not allow VolP VHF to operate and to control the ships in real time Moreover, you will not be able to record VHF and telephone communication at one point and therefore it w ill require lot many separate VHF data recorders which is not recommended by lALA Also, It Will Increase the requirement of manpower as well as IT hardware and software at great extent Therefore we suggest a new configuration which i s attached herewith.
Please see annexure 1
117. 11 2.1.4 d VHF sets Whether those are standalone or VoIP VHF ? Please see our
above suggestion VoIP VHF
Sr. No.
Reference to Invitation of budgetary quote Queries DGLL Reply
Page Clause Description
118. 14 2.2.2 ASTER
IX format
Why only in ASTERIX format? Once a data is received in IVEF format, there are no issues in integrating with a VTS Software.
Please see reply at serial 18 above.
119. 16
2.2.5 a Existing NAIS network is to be used…..
Please give details of NAIS data network If NAIS network is using VSAT terminal for data transfer. Then it Will have a high amount of latency which Will not allow a real-time Tracking and VOIP VHF communication. If new configuration suggested by us is implemented, it Will solve this issue.
120. 16
2.2.6 (a to i) The software features asked under this clause are very
basic. We suggest to include the latest features like built-in
Geographical Information System (SIS), open standards like
ODBC, WMS. It should have:
a) Fast response user interface
b) 2D 8: 3D viewing ,
c) Warning calculation feature,
d ) Geo referenced map, charts and imagery: S-57, S-63,
MIF, ADRG, MIF, JPEG, DTED, MrSid, etc.
e) Service oriented architecture
f ) Breaks the land/sea [dry/wet) div1de
g] Dynamic Risk Assessment
h) Connection to centralized data bases.
i) Support drag and drop for OLE objects
j) High quality radar video
k) Centralized tracking I) Intelligent sensor fusion
m) Above and Below Water Sensors
n) Radar/ Radio coverage analysis
o) Visualization of drift models for search and rescue/ oil spill
p) Meteorological and Oceanographic data
q) Interception Tool: Course to intercept and closet point of approach
r) Interoperability with other domain awareness system
s) Search & Rescue features
t) Web casting features
u) Route manager features
v) In terceptor tool
w) Satellite AIS tracking feature
x) Synthetic Aperture Radar (SAR) feature
y) LRIT Track feature
z)Traffic Analysis, etc.
Follow the functionality requirement as per IALA guidelines. System should have capability for integration with :-
i)Satellite AIS
ii) LRIT
iii) VDES
121. 20
2.2.11 ….. edit and change the S52 schemes ………
Under cl. No.2.2.11 (b) you have asked for S63 format. So is this a typographical error? It should be S63 in place of S52.
“S52”in page no. 20 may be read as “S63”
122. 22
2.2.17 CCTV system
CCTV System specifications shown do not clarify about what kind of target you want to see. Kindly clarify what size of ship and from what distance you want to monitor. At the same time, what object on that ship you want to monitor.
Please see reply at serial no. 19 above.
123. 24
2.2.19 Alarm Cl no. 2.2.19Systemstored automatically for a period of not less than 30 day
The separate recording of alarm system is not at all useful As per lALA, all sensor data as well as VHF and telephone communication should be recorded all together With date and time stamping to create a holistic picture so that while retrieving data one has to specify only date and time period and all the sensor data like radar, AIS, metrological & hydrological sensors, LRIT fusion, VHF and telephone voice communication with respective channels
including alarm generated by the system will be reproduced.
Requirement of recording/storing alarm for 30 days is deleted.
124. 26
2.2.30 128-bit architecture
Which microprocessor is providing 1 28 bit architecture and with
operating system 15 supporting 128 bit architecture ? 64bit
architecture i s available in the market. The processors
manufacture like Intel and AMD are producing and HP,
DEL and IBM are using 64 bit processors for
manufacturing servers and PCs
Please see reply at serial 20 above
125. 26 2.2.30 8 GB RAM 16 GB is recommended. Please see
annexure 5
126. 26 2.2.30 Disk storage Does it refer to hard disk and what is the capacity required?
We suggest new solid state drives instead of HDD. Please see reply at serial 21 above
127. 26
2.2.30 (g & i) DAT drives/High speed back tape drive system
DAT drives and High Speed back tape drive system are
sequential backup system. Retrieval Will be slow Will you
still require?
We suggest highly reliable SAN [Storage Area Network)
drive in redundancy
Please see reply at serial 21 above
128. 26
2.2.30 j Operating System UN IX/ LINUX
Why only
UNIX/ LINUX operating system is required?
We suggest that windows operating system should also
be allowed to create healthy competition.
All over the world 90% VTMS are using Windows
operating System Even in India, except Gulf of Kutch
VTS, all other VTMS are using Windows Operating
System. This is also contradicting w1th your clause no
2 2 32 [a] on pg. no 27 "Server running MS SQL Server
2008 or better". SQL Server 2008 itself requires Microsoft
Windows operating system. VTMS of Singapore,
English Channel -MCA. Canadian Coast Guard VTS,
Los Angeles VTS, Indonesia VTMS System and many
other Important port VTS of the globe are using
Windows operating system
Please see reply at serial 22 above
129. 29
2.2.34 As suggested earlier, all sensor data as well as all type of communication including VHF 8; telephone communication should be recorded together with date and time stamping It should not be required to synchronize VHF communication with radar and AIS sensors. It should be automatic Delete/ erase recorded volume through password should never be allowed otherwise, true incident scenario cannot be retrieved . The VHF audio recording should b e 'must 'and not 'shall be possible' as mentioned in [1].
130. 30
BOM, Sl A(1) Provision of circular Polarization
On page no 13, cl No 2.1.1 (iii), you have
Mentioned horizontal polarization only Do you require both
polarization in BOQ?
If both polarization are required, the word 'provision'
should be replaced with 'switchable'.
Please see reply at serial no. 23 above.
131. 30
BOM Sl A(2) Radar Data Processor Unit
Do you mean radar extractor and tracker unit and how have you arrived at the quantity of 168 ? If you consider the existing 34 radar + new 45 radars + 84 ICG radars and if you require radar data processor/radar extractor& tracker in redundancy, you may require 326 units. Without having radar extractor & tracker in redundancy, there is no point of having radar transceivers in redundancy.
Please see revised bill of Material at annexure 2
132. 30 BOM Sl A(3) Radar
display unit- 84 nos
Do you mean 84 nos of display monitors or 84 nos of consoles, each with three monitors?
Please see revised bill of Material at annexure 2
133. 30 Kindly let us know how you have derived the quantity of Bill of
Material of all the items Please see revised bill of Material at annexure 2
ANNEXURE 1
SYSTEM ARCHITECTURE FOR NCVTS
National Monitoring
Center(Mirror Image)Vizag
National Monitoring Center
Mumbai(Bhandup)
Data Aggregation Center (Jamnagar, Mumbai, Goa, Cochin, Chennai, Vizag,
Bhubaneshwarr, Kolkata and Port Blair)
Radar
station 1
Radar
station 2 Radar
station n
Port Monitor
center
State Maritime
police
State Maritime
Board
Existing
VTS
CSN Radars Phase I
Indian Navy
Coast Guard
DG Comm
Mumbai
Feed
from NAIS
CSN Radars Phase II
ANEXXURE-2
BILL OF MATERIAL
SL.
NO.
EQUIPMENT
QTY. Unit
Price in
Rs.
inclusive
of all
taxes and
duties
Amount
in Rs.
Remarks
A
X BAND VTS RADAR
1
SUPPLY, INSTALLATION, TESTING AND
COMMISSIONING OF DUAL
TRANSCEIVER X BAND SOLID STATE, 50-
200 W RADAR, COMPLIANT OF IALA VTS
STANDARD WITH 21 FEET SWG
HORIZONTAL POLARIZED ANTENNA
WITH SWITCHABLE CIRCULAR
POLARIZATION AND FREQUENCY
DIVERSITY.
45
2 RADAR DATA PROCESSOR UNITS 262
3 RADAR DISPLAY UNITS 45
B 1 ENC CHARTS FOR INDIAN COAST TO BE
INSTALLED AT ALL NODES OF NCVTS
LS
C 2
INTEGRATION OF EXISTING VTS
SYSTEMS AT 12 MAJOR PORTS, GULF OF
KUTCH, GULF OF KHMABHAT AND
INTEGRATION OF RAW RADAR DATA
FROM RADAR OF CSN NETWORK
LS
D
VTS DATA FEED TO IN, ICG, BSF, SMB,
SMAS, DGS, PORT AUTHORITIES,
CUSTOMS ETC INCLUDING FUTURE
PROVISIONING
100
E
VHF SYSTEM
(with 02 telephone lines patching feature at
09 Data Aggregation Centers)
1 VHF SYSTEM WITH VOIP 322
2 VHF SERVER WITH RECORD AND
REPLAY PROVISION INCLUDING
09
3 PRESS TO TALK FACILITY ON VHF
OVER VOIP (05 AT EACH DAC)
45
F
CAMERA SYSTEM
1 LONG RANGE OPTIC CAMERA
SYSTEM
30
G
METEO SYSTEM
1
METEO SENSOR WITH UNIVERSAL
SERIAL INTERFACE ( WIND SPEED &
DIRECTION, HUMIDITY,
PRECIPITATION, TEMPERATURE AND
BAROMETRIC PRESSURE)
30
H
VTS SOFTWARE, NETWORKING
AND HARDWARE
1 VTS SOFTWARE 01
2 DATA NETWORKING JOB 01
3 DBMS SERVER AT 09 DAC, 02NMC 22
4 NETWORK SERVER 09
CENTRAL OPERATION PROCESSER 18
5 RECORD AND REPLAY SYSTEM TO BE
INSTALLED AT ALL PROCESSOR
09
I
CONNECTIVITY
1 VSAT SYSTEM PAMA PER SITE
INDORE UNIT (IDU MODEM ONBOARD
TCP OPTIMIZATION AND QOS
(QUALITY OF SERVICE)
CAPABILITIES, ROUTER AND DNS
AND CMPATIBLE WITH Ku and C
BAND
45
2 OUTDOOR UNIT (VSAT SATELLITE
DISH, LNB AND BUC
45
3
2MBPS LEASED LINE FROM ALL
RADAR STATIONS TO BSNL CLOUD
and FROM BSNL CLOUD TO DAC
131
4
8MBPS LEASED LINE FROM DAC TO
NATIONAL MONITORING CENTRE
WITH NETWORKING DEVICES
02
J
DISPLAY
1
LED DISPLAY 24” TERMINAL /
OPERATOR’S
CONSOLE(1CPU+2MONITOR+1
MOUSE)
118
2
OFFICE PC WITH MULTIFUNCTION
COLOUR PRINTER WITH FURNITURE
AND INTERNET CONNECTION (i7 OR
BETTER)
11
L
ELECTRICAL
1 DG SET (40 KVA) 45
2 UPS WITH BATTERY, 3 PHASE (15KVA) 45
3 UPS WITH BATTERY (6 KVA) 87
4 UPS WITH BATTERY (20KVA) 09
5 UPS WITH BATTERY (10KVA) 4
6 LIGHTENING PROTECTION 100
7 EARTHING 100
8 ELECTRICAL WIRING PROTECTION
DEVICES 100
9 AIR CONDITIONING 1.5 Ton 5 Star Rating 252
M
CAMC
1 CAMC FOR NINE YEARS
N
TRAINING
1 TECHNICAL TRAINING FOR 02 WEEKS
FOR 24 ENGINEERS
O
1
INSTALLATION, COMMISSIONING
AND DOCUMENTATION
1
Q
ESSENTIAL SPARES
-Radar and associated components
-Networking
-VHF Equipment
LS
GRAND TOTAL
ANNEXURE -3
LIST OF EXISTING VTS AND DETAILS
Sl.
No. Location
No. of
Radars
System
Integrator Radar
Year of
Installation
1. Gulf Of Kuchh, Gujarat 09 HITT (SAAB) Terma 2012
2. Gulf of Khambat, Gujarat 08 Kongsberg Selesmar 2010
3. JNPT-Mumbai, Maharashtra 03 STN Atlas Atlas 2011
4. Mormugao, Goa 01 Kongsberg Litton 2001
5. New Mangalore, Karnataka 01 Transas GEM 2016
6. Cochin, Kerala 02 Transas GEM 2009
7. Tutucorin, TN 01 Vissim GEM 2014
8. Chennai, TN 01 Kongsberg Selesmar 2015
9. Visakhapatnam, AP 01 Transas Transas 2016
10. Paradeep, Odisha 02 Transas Raytheon 2012
11. Kolkata-Haldia, WB 04 Kongsberg Selesmar 2012
12. Ennore, Chennai 01 Kongsberg Selesmar 2015
Annexure - 4
TENTATIVE LIST OF STATIONS FOR NCVTS FOR INSTALLATION OF NEW RADAR AND VHF SETS.
SL.No State Location
1. Gujarat Navibunder
2. Canai creek
3. Maharashtra Kelshi
4. Jaigarh
5. Wagapur Point
6. Achara
7. Vengrula Point
8. Redi Port
9. Goa Betul
10. Caba-de Rama.
11. Karnataka Oyster Rocks
12. Karwar port
13. Tadri
14. Honawar
15. Kap
16. Kerala Kannur
17. Chetwai
18. Valiyazheekal
19. Anjergo
20. Tamil Nadu Muttam Point
21. Kutankulam
22. Vembar
23. Dhanushkodi
24. Mallipatam
25. Adirapatnam
26. Kadapakkam
27. Mahabalipuram
28. Andra Pradesh Iskapalii
29. Kothapatnam
30. Nagalayanka
31. Rava Port
32. Pentakota
33. Pudimatka
34. Bhimunipatnam
35. Bavanapedu
36. Odisha Prayagi.
37. Devi Point
38. False Point
39. Maipura
40. Chaumukh
41. Madanpura
42. Chilka
EXISTING RADARS FOR INTEGRATION WITH NCVTS AND INSTALLATION OF NEW VHF SETS
Sl.No State No of Stations
01 Gujarat 09
02 Maharashtra 08
03 Goa 01
04 Karnataka 04
05 Kerala 10
06 Tamil Nadu 14
07 Andra Pradesh 12
08 Odisha 05
09 Lakshadweeps 09
10 Andaman & Nicobar Islands. 07
EXISTING VTS TO BE INTEGRATED WITH NCVTS
Sl.No State No of VTS Location
01 Gujarat 02 Kandla, Dumas (Surat)
02 Maharashtra 01 Mumbai
03 Goa 01 Murmagoa
04 Karnataka 01 New Mangalore
04 Kerala 01 Kochi
05 Tamil Nadu 03 Chennai, Tuticorine, Ennore
06 Andra Pradesh 01 Visakhapatnam
07 Odisha 01 Paradip
08 West Bengal 01 Kolkata
LIST OF PROPOSED PMS
1 Mul Dwarka
9 Veraval 17 Beypore 25 Malpe
2 Dhanau 10 Ulwa Belapur 18 PY3 - Oil Fields
26 Azhikkal
3 Trombay 11 Mora 19 Nagapattinam 27 Neendakara
4 Mandwa 12 Rava 20 Tirukkadaiyur 28 Cuddalore
5 Dhabol 13 Revadanda 21 Machlipatnam 29 Valinokkam
6 Karwar 14 Redi 22 Port Blair 30 Ennore Minor Port
7 Tadri 15 Vijaydurg 23 Kundakulam
8 Mangalore Old Port
16 Belekeri 24 Rameshwaram
Annexure - 5
SPECIFICATION OF IT EQUIPMENTS FOR NCVTS
Sl.no
Locati-on
Equip-ment
Specifications
01 Radar Router
Architecture & Interface Support: Device should have at least 6 x 10/100/1000 ports supporting both LAN and WAN protocols. Device should have two 1 Gb Ethernet Optical Small Form Factor Pluggable (SFP) Ports with SX SFP enabled on one port. The Router should support minimum 2 Mbps bandwidth capacity. Device should support modular LAN and WAN connectivity options including Gigabit Ethernet T1/E1, serial V.35, ADSL2+ physical interface modules. Device box should support IPSEC VPN . Routing protocol support: The Device should support IPv4 and IPv6 routing. The Device should support Static Routes. The Device should have OSPFv2 and IS-IS routing features. The Device should support Routing over IPSec Tunnels. Multicast Features: Multicast Listener Discovery (MLD) IGMP v1/v2/v3 PIM-SM, SSM MPLS Features Layer 2 and Layer 3 VPN LDP and RSVP Security features Devices should support AAA using RADIUS or TACACS Devices should support Packet Filters Devices should support Tunnels (GRE, IP-in-IP, IPSec) Management and Troubleshooting: Device should have Console, Telnet and Web for management. Devices should support Software upgrades through Web Devices should support SNMPv2 and SNMPv3.)
02 DAC Router Architecture & Interface Support: Device should have at least 24 x 10/100/1000 ports supporting both LAN and WAN protocols. Device should have four 1 Gb Ethernet Optical Small Form Factor Pluggable (SFP) Ports with SX SFP enabled on two ports. The Router should support minimum 4 Mbps bandwidth capacity. Device should support modular LAN and WAN connectivity options including Gigabit Ethernet T1/E1, serial V.35, ADSL2+ physical interface modules. Device box should support IPSEC VPN . Routing protocol support: The Device should support IPv4 and IPv6 routing. The Device should support Static Routes. The Device should have OSPFv2 and IS-IS routing features. The Device should support Routing over IPSec Tunnels. Multicast Features: Multicast Listener Discovery (MLD) IGMP v1/v2/v3 PIM-SM, SSM MPLS Features Layer 2 and Layer 3 VPN LDP and RSVP Security features Devices should support AAA using RADIUS or TACACS Devices should support Packet Filters Devices should support Tunnels (GRE, IP-in-IP, IPSec) Management and Troubleshooting: Device should have Console, Telnet and Web for management. Devices should support Software upgrades through Web Devices should support SNMPv2 and SNMPv3.)
03 PMC Router Architecture & Interface Support: Device should have atleast 8 x 10/100/1000 ports supporting both LAN and WAN protocols. Device should have two 1 Gb Ethernet Optical Small Form Factor Pluggable (SFP) Ports with SX SFP enabled on one port. The Router should support minimum 4 Mbps bandwidth capacity. Device should support modular LAN and WAN connectivity options including Gigabit Ethernet T1/E1, serial V.35, ADSL2+ physical interface modules. Device box should support IPSEC VPN . Routing protocol support: The Device should support IPv4 and IPv6 routing. The Device should support Static Routes. The Device should have OSPFv2 and IS-IS routing features. The Device should support Routing over IPSec Tunnels. Multicast Features: Multicast Listener Discovery (MLD) IGMP v1/v2/v3 PIM-SM, SSM MPLS Features Layer 2 and Layer 3 VPN LDP and RSVP Security features Devices should support AAA using RADIUS or TACACS Devices should support Packet Filters Devices should support Tunnels (GRE, IP-in-IP, IPSec) Management and Troubleshooting: Device should have Console, Telnet and Web for management. Devices should support Software upgrades through Web Devices should support SNMPv2 and SNMPv3.)
04 NMC (Mumbai)
Router Architecture & Interface Support: Device should have at least 8 x 10/100/1000 ports supporting both LAN and WAN protocols. Device should have two 1 Gb Ethernet Optical Small Form Factor Pluggable (SFP) Ports with SX SFP enabled on one port. The Router should support minimum 8 Mbps bandwidth capacity. Device should
support modular LAN and WAN connectivity options including Gigabit Ethernet T1/E1, serial V.35, ADSL2+ physical interface modules. Device box should support IPSEC VPN . Routing protocol support: The Device should support IPv4 and IPv6 routing. The Device should support Static Routes. The Device should have OSPFv2 and IS-IS routing features. The Device should support Routing over IPSec Tunnels. Multicast Features: Multicast Listener Discovery (MLD) IGMP v1/v2/v3 PIM-SM, SSM MPLS Features Layer 2 and Layer 3 VPN LDP and RSVP Security features Devices should support AAA using RADIUS or TACACS Devices should support Packet Filters Devices should support Tunnels (GRE, IP-in-IP, IPSec) Management and Troubleshooting: Device should have Console, Telnet and Web for management. Devices should support Software upgrades through Web Devices should support SNMPv2 and SNMPv3.)
05 NMC Vizag
Router Architecture & Interface Support: Device should have at least 8x 10/100/1000 ports supporting both LAN and WAN protocols. Device should have Four 1 Gb Ethernet Optical Small FormFactor Pluggable (SFP) Ports with SX SFP enabled on one port. The Router should support minimum 8 Mbps bandwidth capacity. Device should support modular LAN and WAN connectivity options including Gigabit Ethernet T1/E1, serial V.35, ADSL2+ physical interface modules. Device box should support IPSEC VPN . Routing protocol support: The Device should support IPv4 and IPv6 routing. The Device should support Static Routes. The Device should have OSPFv2 and IS-IS routing features. The Device should support Routing over IPSec Tunnels. Multicast Features: Multicast Listener Discovery (MLD) IGMP v1/v2/v3 PIM-SM, SSM MPLS Features Layer 2 and Layer 3 VPN LDP and RSVP Security features Devices should support AAA using RADIUS or TACACS Devices should support Packet Filters Devices should support Tunnels (GRE, IP-in-IP, IPSec) Management and Troubleshooting: Device should have Console, Telnet and Web for management. Devices should support Software upgrades through Web Devices should support SNMPv2 and SNMPv3.)
06 DAC, NMC
Data base Server Processor
Dual Processors with minimum 8 cores per CPU, 2.5 GHz clock speed and 20 MB cache memory 64 bit instruction set Minimum 8 GT/s system bus Minimum 64 GB DDR 4 ECC memory 5 x 300 GB SAS hot plug HDD with 15K RPM or higher RAID controller with support for RAID 0/1/5/6/10 with minimum 2 GB Cache Minimum Dual Gigabit Ethernet ports 8 Gbps (Minimum) dual port Fiber channel host bus adapter (HBA). Redundant/hot swappable power and cooling units OS: Red Hat Ent. Linux Std (1/2 socket)Version with 1 Year subscription
07 DAC,PMS, NMC
Display Processor
Intel i7 or equivalent. 64 bit architecture, 4 GB RAM, 1 TB HDD, 4 GB NIVIDEA with application software.
08 Radar Station
Radar Data Processor
Intel i7 or equivalent. 64 bit architecture, 4 GB RAM, 1 TB HDD, 4 GB NIVIDEA with application software
09 DAC VHF Server
Intel i7 or equivalent. 64 bit architecture, 4 GB RAM, 1 TB HDD, 4 GB NIVIDEA with application software
10 DAC Central Operation Processor
Dual Processors with minimum 8 cores per CPU, 2.5 GHz clock speed and 20 MB cache memory 64 bit instruction set Minimum 8 GT/s system bus Minimum 64 GB DDR 4 ECC memory 5 x 300 GB SAS hot plug HDD with 15K RPM or higher RAID controller with support for RAID 0/1/5/6/10 with minimum 2 GB Cache Minimum Dual Gigabit Ethernet ports 8 Gbps (Minimum) dual port Fiber channel host bus adapter (HBA). Redundant/hot swappable power and cooling units OS: Red Hat Ent. Linux Std (1/2 socket)Version with 1 Year subscription with application software