MECHANICAL DATA SHEET
FORCED CIRCULATION EVAPORATOR
PLANT ITEM No. 24590-BOF-ME-DEP-EVAP-00001 DATA SHEET No.
Rev.
24590-BOF-MVD-DEP-00009 1
Page 1 of 2
Project: RPP-WTP Description DEP Evaporator Separator Vessel Project No: 24590 Reference Drawings (1) 24590-BOF-ME-DEP-00001001, Rev. 1
Project Site: Hanford Reference Calculations (Internal Use Only)
(2) 24590-BOF-MEC-DEP-00001, Rev A (3) 24590-BOF-MEC-DEP-00003, Rev A (4) 24590-BOF-M6C-DEP-00009, Rev B
Building 25/Indoors Reference Documents (Internal Use Only)
(5) 24590-WTP-DB-ENG-01-001, Rev 5 (6) 24590-WTP-Z0C-W13T-00010, Rev. G (7) 24590-QL-POA-MEVV-00002-08-00006, Rev. A (8) Deleted
Reference Data Charge Vessels (Tag Numbers) None Pulsejet Mixers / Agitators (Tag Numbers) None RFDs/Pumps (Tag Numbers) None
Design Data Quality Level CM Fabrication Specs 24590-BOF-3PS-MEVV-T0001 Seismic Category SC-IV Design Code ASME Section VIII, Div. 1
Service/Contents Radioactive Liquid, Radioactive Gas/Vapor
Code Stamp Yes
Density of Fluid (normal/max) (Ref. 3)
lb/ft3 68.7/84.3 NB Registration Yes
Maximum Operating Volume (Ref.7) (Note 8)
gal 1177 Weights (lbs) Empty Operating Test
Total Volume (Ref. 7) (Note 8)
gal 3544 Estimated 16,000* 29,500* 46,700*
Feed Flow Rate (Ref. 2) gpm 10
Actual ** ** **
Net Boil-off Rate (Normal/Max) (Ref. 3) (Note 9)
gpm 9.0/9.4 Not to exceed wet weight (lb) 57,500
Area Classification (Note 4) R4/C5 Ambient Room Temp (Min/Max) °F 59 / 113
Inside Diameter (Ref. 1)
feet 4’ -6” (Upper), 6’-5” (Lower) Wind Design Not Required
Height (T-T) / Overall (Ref. 1)
feet 17’ – 3 5/8” / 23’ – 2 7/8” Snow Design Not Required
Vessel Operating
Vessel Design
Coil/ Jacket Design
Seismic Design 24590-BOF-3PS-MEVV-T0001
Internal Pressure (Ref. 2, 4) psig 0 50 N/A Postweld Heat Treat Per Code
External Pressure (Ref. 2, 4) psig
12.9 (Note 6)
14.7/FV N/A Corrosion/Erosion Allowance Inch 0.04
Temperature (Ref. 2, 4) °F 116 175 N/A
Min. Design Metal Temp. (Ref. 5) °F 59
Materials of Construction Component Material Containment Notes
Top Head SB575 (Hastelloy C-22) UNS N06022 Auxiliary Shell SB575 (Hastelloy C-22) UNS N06022 Primary Bottom Cone SB575 (Hastelloy C-22) UNS N06022 Primary Vessel Support Plate
SA 240 304L SS Pipe (Trunnion) SA 312 SML 304L SS
N/A Max carbon content of 0.030%
Jacket/Coils/Half-Pipe Jacket N/A N/A
Issued byRPP-WTP PDC
-
I
----I
I I
I -
I
====f -1,--
I--
-
-
I I
-I--
I I
I I
l I I
-I -I
I--
I
I I T ~
I L 7 l
-
MECHANICAL DATA SHEET PLANT ITEM No. 24590-BOF-ME-DEP-EVAP-00001
FORCED CIRCULATION EV APO RA TOR • DATA SHEET No. Rev. 24590-BOF-MVD-DEP-00009 1 Bubble Cap Tray UNS N06022 (Hastelloy C-22) N/A Mesh Pad UNS N06625 (Alloy 625) N/A Pipe SB622 (Hastelloy C-22) UNS N06022 N/A Forgings/ Bar stock (internal) SB564 (Hastelloy C-22) UNS N06022 N/A Gaskets SB575 (Hastelloy C-22) UNS N06022 Auxiliary
Spiral Wound w/ Thenniculite Filler with Inner and Outer Rings
Bolting SA193 BBS UNS S21800 (Nitronic) Auxiliary 60 w/ 400 series SS nuts
Miscellaneous Data Orientation Vertical Insulation Function Heat Conservation Insulation Thickness (inch) Note7 Support Type Note3
Notes Seller to fill in data where indicated by double asterisk (**). Data from Seller's proposal indicated with asterisk (*). Seller to confirm all data.
Notes 1. The contents of this document are Dangerous Waste Permit affecting. 2. Please note that source, special nuclear and byproduct materials, as defined in the Atomic Energy Act of 1954 (AEA),
are regulated at the U.S. Department of Energy (DOE) facilities exclusively by DOE acting pursuant to its AEA authority. DOE asserts, that pursuant to the AEA, it has sole and exclusive responsibility and authority to regulate source, special nuclear, and byproduct materials at DOE-owned nuclear facilities. Information contained herein on radionuclides is provided for process description purposes only.
3. Evaporator Separator Vessel support frame to be supplied by Buyer and support trunnions and lugs to be supplied by Seller.
4. This equipment is located in an R4 radiation area (Maximum Radiation Area), which is designed to have a target radiation level of less than 25 mrem/hr (Ref. 5, Table 5-1). The average contact dose rate is 6.56E+01 rad/hr for an equipment life of 21+ years (Ref. 6, Table 8-1).
5. See Ref. 1 for connecting piping sizes and end connections. 6. Ref. 2 gives the evaporator operating pressure as 1.45 psia. This is converted to psig by subtracting 14.35. Since this
is an external pressure on the vessel, the negative sign is not needed. 7. DEP-EVAP-00001 is designed with provisions for 2-inch thickness of heat conservation (HC) insulation. The top head
insulation is Expanded Perlite (Density= 13 lb/ft3), the bottom head insulation is Mineral Fiber Blanket (Density= 8 lb/ft3), and the shell insulation is Mineral Fiber Semi Rigid Board (Density = 8 lb/ft3). The insulation is provided and installed under an insulation subcontract.
8. Ref. 7 is the sizing calculation for the CNP evaporator. Ref. 3 confirms the CNP evaporator design will meet the requirements for the DEP design.
9. Ref. 2 provides evaporator feed and concentrate product flow rates. To calculate net boil-off rate, use equation: Net Boil-off (gpm) = Feed Flow (gpm) - Concentrate Product Flow (gpm).
A I ,oorova Rev Description Originator Checked Reviewed Approved Date
0 Issued for Procurement Holden Erica Debbie Youssef 12/22/16 Carroll Poberezny Adler Mohammad-Zadeh
1 Issued for Purchase Erica Holden Youssef Revised conform to Seller's Poberezny Carroll Mohammad-Zadeh
G/1/rr offering and update Checked v f'1 materials and material By: HoldenC•r"' ll -hvcarrol rReviewed it j Originator '""'!>I OrgNar!'ll: Bed'IIIII Nallolial lnc l!.t!.S.W!Pioot"ts descriptions. There are no By Enca Poberezny • •Pf'berez. _L .c.d• Ji.in01,2017 Org Name: MET Orv N•11111 · BKhl•I Nlll!onai, Inc LF'111CK: J1111D1,2017 applicable EIEs. Placed• Jul\01.2017 Page 2 of2