Reducing The Risk Of Utility Related Equipment

Failures

REDUCING THE RISK OF UTILITY RELATED EQUIPMENT FAILURES

WWW.BATTERYBACKUPPOWER.COM | 855.330.7799

SOLUTIONS that work for your business, lab, or data center

Simplifying POWER

Page 2: REDUCING THE RISK - Shopify · 2020-04-02 · personal property (servers, lab instruments, electrical systems, etc.), the utility company will compensate the customer for the cost

| 2

Battery Backup Power, Inc. was established in 2014 and is backed by multiple publicly traded companies with exclusive technology rights to select product lines. The company was established by utility professionals looking to resolve customer issues related to power that regulated utility companies could not solve.

About Us:

Battery Backup Power, Inc:Battery Backup Power, Inc. focuses on only producing utility grade or above power protection and backup products. This business policy has established the company as a premium, reliable, quality manufacturer of products.

Our Clients:

Battery Backup Power, Inc. UPS At NASA Facility

Battery Backup Power, Inc. UPSAt DNA Testing Laboratory

Battery Backup Power, Inc. UPS At USFWS National Fish & Wildlife Forensics Laboratory

Battery Backup Power, Inc. UPSAt Canadian Government Testing Laboratory

Since 2014, Battery Backup Power, Inc. has secured large and government customers such as NASA, the CDC, the US Navy, the USDA, the FDA, Johns Manville, Bristol Myers Squibb, Standard Process, PAE, and the Canadian National Research Council as well as countless, but not less important smaller customers. Below are a few photos of our UPS in use at our clients facilities.

Page 3: REDUCING THE RISK - Shopify · 2020-04-02 · personal property (servers, lab instruments, electrical systems, etc.), the utility company will compensate the customer for the cost

3 |3 |

“Everything is working very well. We have been very happy with the UPS systems. We use

multiple UPS systems!”

Jonathan V. Ph.D.... | Johns Manville Technical Center

4.9 Stars

“The system you set us up with is working wonderfully!”

Andrew H. | ACT Laboratories

“Battery Backup Power, has been supplying our maintenance department with excellent double

conversion units that do a terrific job of protecting and backing up the power for phone systems, repeaters

and PA systems.

Besides the outstanding products, the service and support we receive from Ross, is unmatched.”

Rocky D. | Palos Verdes Peninsula Unified School District

“The UPS arrived, we got it hooked up, and its been tested a few times. We

are really happy to have that particular instrument on backup. We will be

ordering more units as soon as our funding is secured.”

Wendy | USGS

“I have been very pleased with the UPS unit. I have not had to concern myself with it ever since it was plugged in and the output verified. I need another one of the UPS units in Q1 next year. We are planning to purchase

another precision instrument.” Gee | Sample Tech Labs

Terrific Job...Outstanding Product, Service and Support

WONDERFUL!

Very Happy!

We Will Be Ordering

More UnitsSet It & Forget it! Worry Free!

Page 4: REDUCING THE RISK - Shopify · 2020-04-02 · personal property (servers, lab instruments, electrical systems, etc.), the utility company will compensate the customer for the cost

| 4

Battery Backup Power, Inc. has a multi-faceted ap-proach to mitigating risks to equipment caused by utility power irregularities. This involves integrating the below features in its products as a minimum.

How We

Reduce Utility Related Equipment Failures:

| 4

Page 5: REDUCING THE RISK - Shopify · 2020-04-02 · personal property (servers, lab instruments, electrical systems, etc.), the utility company will compensate the customer for the cost

5 |

Our Competitive Advantages:

An Inside Look at Our ProductsOur UPSAll of our UPS are fullyEquipped with:

• Voltage Regulation• Frequency Regulation• Utility Grade Power Output

(Pure Sinewave)• Always on Backup Power

with No Delay (Double Conversion)

• Electrical Noise Filtration (Isolation Transformer) (6KVA & 10KVA Only)

• Surge Suppression• Circuit Protection

Our PDUAll of our PDUs have:

• Plug and play compatibility with 99% of all electronics designed for use in the United States.

• Dual voltage output allowing for devices using standard plugs like computers and higher voltage devices using specialized plugs to operate on a single UPS.

• Individual circuit protection providing an additional layer of electrical protection.

Page 6: REDUCING THE RISK - Shopify · 2020-04-02 · personal property (servers, lab instruments, electrical systems, etc.), the utility company will compensate the customer for the cost

| 6

Our Competitive Advantages:

An Inside Look at Our Production & ShippingWe build, customize and ship your order in California.

Once the UPS is fully built we then inspect every port ensuring that the output is +- 1%

of your specifications.

Below is a Sine Wave Test, as all of our UPS put out Pure Sine Waves.

We take shipping just as seriously as our products. We have No Stack Cones, Tip Gauges, Stickers, Custom Designed Pallets with Feet, Shrink Wrap and more.

Page 7: REDUCING THE RISK - Shopify · 2020-04-02 · personal property (servers, lab instruments, electrical systems, etc.), the utility company will compensate the customer for the cost

7 |

Understanding the

Electric Utility Company Responsibilities:

Utility failures are the leading cause of California wildfires, customer owned electrical equipment failures (servers, networking equipment, lab instruments, etc.), downed power line electrocutions, and other electrical related incidents.

Generally, electric utility companies are responsible for losses that occur due to provable negligence and not causes beyond their control (weather related, accidents, third party negligence, etc). This means the customer has to prove beyond a reasonable doubt that the damage was caused by the utility company’s negligence to begin to seek reparations. Anything related to weather is automatically thrown out.

If the utility company does eventually accept responsibility for damage to a customer’s personal property (servers, lab instruments, electrical systems, etc.), the utility company will compensate the customer for the cost of the following: repair, fair market value, or replacement. For items that are not new (this is pretty much everything) and cannot be repaired, fair market value is determined by the estimated value the item would have just prior to the damage occurring.

This means that if a server, lab instrument, or other equipment is proven to be damaged by the utility’s negligence beyond a reasonable doubt, only the hardware value of that equipment at the time it was damaged will be reimbursed. This does not include the revenue lost due the equipment’s failure, the cost to program/setup/install new replacement equipment, or any other cost associated with the failure and replacement.

For example, a server rack filled with $50,000 worth of IT equipment that produces $6,000,000 a year in revenue for a business may only result in a reimbursement check of about $5,000 after 2 years in court or settlement proceedings have proven the utility company was responsible for the equipment failure. This is due to the fact that the hardware value of the equipment at the time of the incident is the only cost considered. Fair market value of IT equipment is typically minimal as it is considered obsolete as soon as it is purchased. This typically results in a small to mid-sized business going out of business or a large business suffering irreparable damage to long term revenue generation.

Page 8: REDUCING THE RISK - Shopify · 2020-04-02 · personal property (servers, lab instruments, electrical systems, etc.), the utility company will compensate the customer for the cost

| 8

Understanding theElectrical Utility Company’s Areas Of Responsibility:Below is a graphical representation of what the customer is responsible for compared to what the Utility Company is. Utility Companies are responsible for everything in RED while customers are responsible for the areas marked in GREEN.

Utility Owned vs Customer Owned Equipment

Page 9: REDUCING THE RISK - Shopify · 2020-04-02 · personal property (servers, lab instruments, electrical systems, etc.), the utility company will compensate the customer for the cost

9 |

Utilities Actively regulate distribution voltages slowly by means of tap changing regulators and by switching capacitors to follow changes in load. These voltage changes are small incremental steeps necessary to keep the service delivery voltage within an acceptable range as customers add and subtract load during the day. This slow regulation maintains a sustained voltage range. Sustained usually means a period greater than two minutes.

The reason for the CBEMA curve is for changes in voltages shorter than two minutes. As described above, there will be excursions outside the acceptable ranges for short “momentary” periods.

9 |

Page 10: REDUCING THE RISK - Shopify · 2020-04-02 · personal property (servers, lab instruments, electrical systems, etc.), the utility company will compensate the customer for the cost

| 10

Voltage Tolerance BoundaryThe only national standard for utilization voltage regulation is ANSI C84.1. Its title is American National Standard for Electric Power Systems and Equipment – Voltage Ratings (60 Hertz). The first version in 1954 was a combination of two standards, one from the Edison Electric Institute that represents utilities and the second from NEMA that stands for National Electrical Manufacturers Association. It establishes nominal voltage ratings for utilities to regulate the service delivery and it establishes operating tolerances at the point of use. The design and operation of power systems and the design of equipment to be supplied from such systems should be coordinated with respect to these voltages.

In doing so, the equipment will perform satisfactorily in conformance with product standards throughout the range of actual utilization voltages that will be encountered on the system. These limits shall apply to sustained voltage levels and not to momentary voltage excursions that may occur from such causes as switching operations, fault clearing, motor starting currents, and the like.

To further this objective, this standard establishes, for each nominal system voltage, two ranges for service voltage and utilization voltage variations, designated as Range A and Range B, the limits of which are illustrated in figure 1 based on a 120 volt nominal system.

Figure 1.Voltage Ranges, ANSI C84.1NOTES:(a) These shaded portions of the ranges do not apply to circuits supplying lighting loads(b) This shaded portion of the range does not apply to 120-600-volt systems.(c) The difference between minimum service and minimum utilization voltages is intended to allow forvoltage drop in the customer’s wiring system. This difference is greater for service at more than 600 volts to allow for additional voltage drop in transformations between service voltage and utilization equipment.

Page 11: REDUCING THE RISK - Shopify · 2020-04-02 · personal property (servers, lab instruments, electrical systems, etc.), the utility company will compensate the customer for the cost

11 |

The 6KVA/6KW and 10KVA/10KW plug and play UPS models are the most popular units as an IT staff member or lab technician can unpack, turn on, and plug in the UPS within 5 minutes. Time consuming and expensive electrical work is eliminated as the UPS plugs into a single receptacle (NEMA L6-30R for the 6KVA & NEMA 6-50R for the 10KVA). Those models are highlighted in YELLOW.

*UPS Should Be A Minimum of 20% More than the Wattage Rating Of The Equipment You Need To Protect

Our Standard Product Line:

Model #: Description: Photo:

BBP-AR-1000-PSW-ONL

1000 VA / 900 Watt Digital Tower Battery Back-up UPS And Power Conditioner Input: NEMA 5-15P (Plug, 120 VAC, 60 Hz) Output: 6x NEMA 5-15R (Receptacle, 120 VAC, 60 Hz)

BBP-AR-1000-PSW-ONL-EBP

Extended Backup Time External Battery Pack For 1000 VA Digital Tower System

Input/Output: Anderson Pole Quick Connect

BBP-AR-1500-PSW-ONL

1500 VA / 1,350 Watt Digital Tower Battery Backup UPS And Power Conditioner

Input: NEMA 5-15P (Plug, 120 VAC, 60 Hz) Output: 6x NEMA 5-15R (Receptacle, 120 VAC, 60 Hz)

BBP-AR-1500-PSW-ONL-EBP

Extended Backup Time External Battery Pack For 1500 VA Digital Tower System

Input/Output: Anderson Pole Quick Connect

BBP-AR-2000-PSW-ONL

2000 VA / 1,800 Watt Digital Tower Battery Backup UPS And Power Conditioner

Input: NEMA 5-20P (Plug, 120 VAC, 60 Hz) Output: 8x NEMA 5-15/20R (Receptacle, 120 VAC, 60 Hz)

BBP-AR-2000-PSW-ONL-EBP

Extended Backup Time External Battery Pack For 2000 VA Digital Tower System

Input/Output: Anderson Pole Quick Connect

Page 12: REDUCING THE RISK - Shopify · 2020-04-02 · personal property (servers, lab instruments, electrical systems, etc.), the utility company will compensate the customer for the cost

| 12

BBP-AR-3000-PSW-ONL

3000 VA / 2,700 Watt Digital Tower Bat-tery Backup UPS And Power Conditioner (110/115/120 Volts)

Input: NEMA L5-30P (Plug, 120 VAC, 60 Hz) Output: 8x NEMA 5-15/20R (Receptacle, 120 VAC, 60 Hz), 1x NEMA L5-30R (Receptacle, 120 VAC, 60 Hz)

BBP-AR-3000-PSW-ONL-EBP

Extended Backup Time External Battery Pack For 3000 VA Digital Tower System

Input/Output: Anderson Pole Quick Connect

BBP-AR-1000RM-PSW-

ONL

1000 VA / 900 Watt Digital Convertible Rack Mount/Tower Battery Backup UPS And Power Conditioner Input: NEMA 5-15P (Plug, 120 VAC, 60 Hz) Output: 6x NEMA 5-15R (Receptacle, 120 VAC, 60 Hz)

BBP-AR-1000RM-PSW-

ONL-EBP

Extended Backup Time External Battery Pack For 1000 VA Digital Convertible Rack Mount/Tower System

Input/Output: Anderson Pole Quick Connect

BBP-AR-1500RM-PSW-

ONL

1500 VA / 1,350 Watt Digital Convertible Rack Mount/Tower Battery Backup UPS And Power Conditioner

Input: NEMA 5-15P (Plug, 120 VAC, 60 Hz) Output: 6x NEMA 5-15R (Receptacle, 120 VAC, 60 Hz)

BBP-AR-1500RM-PSW-

ONL-EBP

Extended Backup Time External Battery Pack For 1500 VA Digital Convertible Rack Mount/Tower System

Input/Output: Anderson Pole Quick Connect

BBP-AR-2000RM-PSW-

ONL

2000 VA / 1,800 Watt Digital Convertible Rack Mount/Tower Battery Backup UPS And Power Conditioner

Input: NEMA 5-20P (Plug, 120 VAC, 60 Hz) Output: 6x NEMA 5-15/20R (Receptacle, 120 VAC, 60 Hz)

BBP-AR-2000RM-PSW-

ONL-EBP

Extended Backup Time External Battery Pack For 2000 VA Digital Convertible Rack Mount/Tower System

Input/Output: Anderson Pole Quick Connect

BBP-AR-3000RM-PSW-

ONL

3000 VA / 2,700 Watt Digital Convertible Rack Mount/Tower Battery Backup UPS And Power Conditioner (110/115/120 Volts)

Input: NEMA L5-30P (Plug, 120 VAC, 60 Hz) Output: 6x NEMA 5-15/20R (Receptacle, 120 VAC, 60 Hz), 1x NEMA L5-30R (Receptacle, 120 VAC, 60 Hz)

Model #: Description: Photo:

Page 13: REDUCING THE RISK - Shopify · 2020-04-02 · personal property (servers, lab instruments, electrical systems, etc.), the utility company will compensate the customer for the cost

13 |

BBP-AR-3000RM-PSW-

ONL-EBP

Extended Backup Time External Battery Pack For 3000 VA Digital Convertible Rack Mount/Tower System

Input/Output: Anderson Pole Quick Connect

BBP-ADV-6000-PSW-ONL

6000 VA / 6,000 Watt N+1 Digital Tower Battery Backup UPS And Power Conditioner

Input: Hardwire (208/220/230/240 VAC, 50/60Hz)

Output: Hardwire (120/208/220/230/240 VAC, 120 + 208 VAC, 120 + 240 VAC, Or 115 + 230 VAC, 50/60Hz), Determined By Terminals Selected When Wiring And Voltage Selection From Front LCD

BBP-ADV-6000-PSW-ONL-615P-615R-XXX (XXX Indicates Output Voltage, For Ex-

ample 208)

6000 VA / 6,000 Watt N+1 Digital Tower Battery Backup UPS And Power Conditioner

Input: NEMA 6-15P (Plug, 208/220/230/240 VAC, 50/60Hz)

Output: NEMA 6-15R (Receptacle, 208/220/230/240 VAC, 50/60Hz)

BBP-ADV-6000-PSW-ONL-620P-620R-XXX (XXX Indicates Output Voltage, For Ex-

ample 208)

6000 VA / 6,000 Watt N+1 Digital Tower Battery Backup UPS And Power Conditioner

Input: NEMA 6-20P (Plug, 208/220/230/240 VAC, 50/60Hz)

Output: NEMA 6-20R (Receptacle, 208/220/230/240 VAC, 50/60Hz)

BBP-ADV-6000-PSW-ONL-

L630P-L630R-XXX (XXX

Indicates Output Voltage, For Ex-

ample 208)

6000 VA / 6,000 Watt N+1 Digital Tower Battery Backup UPS And Power Conditioner

Input: NEMA L6-30P (Plug, 208/220/230/240 VAC, 50/60Hz)

Output: NEMA L6-30R (Receptacle, 208/220/230/240 VAC, 50/60Hz)

BBP-ADV-6000-PSW-ONL-L630P-

120240PDU-XXX-XXX (XXX-XXX Indicates Output Voltage, For Ex-ample 120-240, 120-208, or 115-

230)

6000 VA / 6,000 Watt N+1 Digital Tower Battery Backup UPS And Power Conditioner

Input: NEMA L6-30P (Plug, 208/220/230/240 VAC, 50/60Hz)

Output: 8x NEMA 5-15/20R (Receptacle, 115/120 VAC, 50/60 Hz), 1x NEMA L5-30R (Receptacle, 115/120 VAC, 50/60 Hz), 2x NEMA L6-15R (Receptacle, 208/230/240 VAC, 50/60 Hz, Twist Lock), 1x NEMA L6-20R (Recepta-cle, 208/230/240 VAC, 50/60 Hz, Twist Lock), 4x NEMA 6-15/20R (Receptacle, 208/230/240 VAC, 50/60 Hz, Straight Blade), And 1x NEMA L6-30R (Receptacle, 208/230/240 VAC, 50/60 Hz, Twist Lock)

BBP-AR-3000-PSW-ONL

3000 VA / 2,700 Watt Digital Tower Bat-tery Backup UPS And Power Conditioner (110/115/120 Volts)

Input: NEMA L5-30P (Plug, 120 VAC, 60 Hz) Output: 8x NEMA 5-15/20R (Receptacle, 120 VAC, 60 Hz), 1x NEMA L5-30R (Receptacle, 120 VAC, 60 Hz)

BBP-AR-3000-PSW-ONL-EBP

Extended Backup Time External Battery Pack For 3000 VA Digital Tower System

Input/Output: Anderson Pole Quick Connect

BBP-AR-1000RM-PSW-

ONL

1000 VA / 900 Watt Digital Convertible Rack Mount/Tower Battery Backup UPS And Power Conditioner Input: NEMA 5-15P (Plug, 120 VAC, 60 Hz) Output: 6x NEMA 5-15R (Receptacle, 120 VAC, 60 Hz)

BBP-AR-1000RM-PSW-

ONL-EBP

Extended Backup Time External Battery Pack For 1000 VA Digital Convertible Rack Mount/Tower System

Input/Output: Anderson Pole Quick Connect

BBP-AR-1500RM-PSW-

ONL

1500 VA / 1,350 Watt Digital Convertible Rack Mount/Tower Battery Backup UPS And Power Conditioner

Input: NEMA 5-15P (Plug, 120 VAC, 60 Hz) Output: 6x NEMA 5-15R (Receptacle, 120 VAC, 60 Hz)

BBP-AR-1500RM-PSW-

ONL-EBP

Extended Backup Time External Battery Pack For 1500 VA Digital Convertible Rack Mount/Tower System

Input/Output: Anderson Pole Quick Connect

BBP-AR-2000RM-PSW-

ONL

2000 VA / 1,800 Watt Digital Convertible Rack Mount/Tower Battery Backup UPS And Power Conditioner

Input: NEMA 5-20P (Plug, 120 VAC, 60 Hz) Output: 6x NEMA 5-15/20R (Receptacle, 120 VAC, 60 Hz)

BBP-AR-2000RM-PSW-

ONL-EBP

Extended Backup Time External Battery Pack For 2000 VA Digital Convertible Rack Mount/Tower System

Input/Output: Anderson Pole Quick Connect

BBP-AR-3000RM-PSW-

ONL

3000 VA / 2,700 Watt Digital Convertible Rack Mount/Tower Battery Backup UPS And Power Conditioner (110/115/120 Volts)

Input: NEMA L5-30P (Plug, 120 VAC, 60 Hz) Output: 6x NEMA 5-15/20R (Receptacle, 120 VAC, 60 Hz), 1x NEMA L5-30R (Receptacle, 120 VAC, 60 Hz)

Model #: Description: Photo:

Page 14: REDUCING THE RISK - Shopify · 2020-04-02 · personal property (servers, lab instruments, electrical systems, etc.), the utility company will compensate the customer for the cost

| 14

BBP-ADV-10000-PSW-ONL

10000 VA / 10,000 Watt N+1 Digital Tower Bat-tery Backup UPS And Power Conditioner

Input: Hardwire (208/220/230/240 VAC, 50/60Hz)

Output: Hardwire (120/208/220/230/240 VAC, 120 + 208 VAC, 120 + 240 VAC, Or 115 + 230 VAC, 50/60Hz), Determined By Terminals Se-lected When Wiring And Voltage Selection From Front LCD

BBP-ADV-10000-PSW-ONL-650P-L630R-XXX (XXX Indicates Output Voltage, For Ex-

ample 208)

10000 VA / 10,000 Watt N+1 Digital Tower Bat-tery Backup UPS And Power Conditioner

Input: NEMA 6-50P (Plug, 208/220/230/240 VAC, 50/60Hz)

Output: NEMA L6-30R (Receptacle, 208/220/230/240 VAC, 50/60Hz)

BBP-ADV-10000-PSW-ONL-650P-650R-XXX (XXX Indicates Output Voltage, For Ex-

ample 208)

10000 VA / 10,000 Watt N+1 Digital Tower Bat-tery Backup UPS And Power Conditioner

Input: NEMA 6-50P (Plug, 208/220/230/240 VAC, 50/60Hz)

Output: NEMA 6-50R (Receptacle, 208/220/230/240 VAC, 50/60Hz)

BBP-ADV-10000-PSW-ONL-

1450P-1450R

10000 VA / 10,000 Watt N+1 Digital Tower Bat-tery Backup UPS And Power Conditioner

Input: NEMA 14-50P (Plug, 208/220/230/240 VAC, 50/60Hz)

Output: NEMA 14-50R (Receptacle, 120/240 VAC, 50/60Hz)

BBP-ADV-10000-PSW-ONL-650P-120240PDU-XXX-

XXX (XXX-XXX Indicates Output Voltage, For Ex-ample 120-240, 120-208, or 115-

230)

10000 VA / 10,000 Watt N+1 Digital Tower Bat-tery Backup UPS And Power Conditioner

Input: NEMA 6-50P (Plug, 208/220/230/240 VAC, 50/60Hz)

Output: 8x NEMA 5-15/20R (Receptacle, 115/120 VAC, 50/60 Hz), 1x NEMA L5-30R (Receptacle, 115/120 VAC, 50/60 Hz), 2x NEMA L6-15R (Receptacle, 208/230/240 VAC, 50/60 Hz, Twist Lock), 1x NEMA L6-20R (Recepta-cle, 208/230/240 VAC, 50/60 Hz, Twist Lock), 4x NEMA 6-15/20R (Receptacle, 208/230/240 VAC, 50/60 Hz, Straight Blade), And 1x NEMA L6-30R (Receptacle, 208/230/240 VAC, 50/60 Hz, Twist Lock)

BBP-ADV-10000-PSW-ONL-EBP-

WC

Extended Backup Time External Battery Pack For 6000 VA To 10000 VA Digital Systems

Input/Output: Anderson Pole Quick Connect

Model #: Description: Photo:

Page 15: REDUCING THE RISK - Shopify · 2020-04-02 · personal property (servers, lab instruments, electrical systems, etc.), the utility company will compensate the customer for the cost

15 |

BBP-ADV-10000-PSW-ONL

10000 VA / 10,000 Watt N+1 Digital Tower Bat-tery Backup UPS And Power Conditioner

Input: Hardwire (208/220/230/240 VAC, 50/60Hz)

Output: Hardwire (120/208/220/230/240 VAC, 120 + 208 VAC, 120 + 240 VAC, Or 115 + 230 VAC, 50/60Hz), Determined By Terminals Se-lected When Wiring And Voltage Selection From Front LCD

BBP-ADV-10000-PSW-ONL-650P-L630R-XXX (XXX Indicates Output Voltage, For Ex-

ample 208)

10000 VA / 10,000 Watt N+1 Digital Tower Bat-tery Backup UPS And Power Conditioner

Input: NEMA 6-50P (Plug, 208/220/230/240 VAC, 50/60Hz)

Output: NEMA L6-30R (Receptacle, 208/220/230/240 VAC, 50/60Hz)

BBP-ADV-10000-PSW-ONL-650P-650R-XXX (XXX Indicates Output Voltage, For Ex-

ample 208)

10000 VA / 10,000 Watt N+1 Digital Tower Bat-tery Backup UPS And Power Conditioner

Input: NEMA 6-50P (Plug, 208/220/230/240 VAC, 50/60Hz)

Output: NEMA 6-50R (Receptacle, 208/220/230/240 VAC, 50/60Hz)

BBP-ADV-10000-PSW-ONL-

1450P-1450R

10000 VA / 10,000 Watt N+1 Digital Tower Bat-tery Backup UPS And Power Conditioner

Input: NEMA 14-50P (Plug, 208/220/230/240 VAC, 50/60Hz)

Output: NEMA 14-50R (Receptacle, 120/240 VAC, 50/60Hz)

BBP-ADV-10000-PSW-ONL-650P-120240PDU-XXX-

XXX (XXX-XXX Indicates Output Voltage, For Ex-ample 120-240, 120-208, or 115-

230)

10000 VA / 10,000 Watt N+1 Digital Tower Bat-tery Backup UPS And Power Conditioner

Input: NEMA 6-50P (Plug, 208/220/230/240 VAC, 50/60Hz)

Output: 8x NEMA 5-15/20R (Receptacle, 115/120 VAC, 50/60 Hz), 1x NEMA L5-30R (Receptacle, 115/120 VAC, 50/60 Hz), 2x NEMA L6-15R (Receptacle, 208/230/240 VAC, 50/60 Hz, Twist Lock), 1x NEMA L6-20R (Recepta-cle, 208/230/240 VAC, 50/60 Hz, Twist Lock), 4x NEMA 6-15/20R (Receptacle, 208/230/240 VAC, 50/60 Hz, Straight Blade), And 1x NEMA L6-30R (Receptacle, 208/230/240 VAC, 50/60 Hz, Twist Lock)

BBP-ADV-10000-PSW-ONL-EBP-

WC

Extended Backup Time External Battery Pack For 6000 VA To 10000 VA Digital Systems

Input/Output: Anderson Pole Quick Connect

BBP-AR-33-10K

10000 VA / 10,000 Watt Advanced Digital 3 Phase Battery Backup Uninterruptible Power Supply (UPS) And Power Conditioner

Input: Hardwire (208/220 VAC, 3 Phase, 50/60Hz)

Output: Hardwire (120/208 VAC, 208 VAC, Or 220 VAC, 3 Phase, 50/60Hz), Determined By Terminals Selected When Wiring And Voltage Selection From Front LCD

BBP-AR-33-10K-L2130R-L2130R-

XXX (XXX In-dicates Output Voltage, For

Example 208)

10000 VA / 10,000 Watt Advanced Digital 3 Phase Battery Backup Uninterruptible Power Supply (UPS) And Power Conditioner

Input: NEMA L21-30P (Plug, 208/220 VAC, 3 Phase, 50/60Hz)

Output: NEMA L21-30P (Receptacle, 120/208 VAC Or 220 VAC, 3 Phase, 50/60Hz)

BBP-AR-33-15K

15000 VA / 15,000 Watt Advanced Digital 3 Phase Battery Backup Uninterruptible Power Supply (UPS) And Power Conditioner

Input: Hardwire (208/220 VAC, 3 Phase, 50/60Hz)

Output: Hardwire (120/208 VAC, 208 VAC, Or 220 VAC, 3 Phase, 50/60Hz), Determined By Terminals Selected When Wiring And Voltage Selection From Front LCD

BBP-AR-33-20K

20000 VA / 20,000 Watt Advanced Digital 3 Phase Battery Backup Uninterruptible Power Supply (UPS) And Power Conditioner

Input: Hardwire (208/220 VAC, 3 Phase, 50/60Hz)

Output: Hardwire (120/208 VAC, 208 VAC, Or 220 VAC, 3 Phase, 50/60Hz), Determined By Terminals Selected When Wiring And Voltage Selection From Front LCD

Model #: Description: Photo: