Redring Powerstream Electric Flow Boilers · Radiators or floor heating system. TA Plumbing Schemes...

12
Redring Powerstream Electric Flow Boilers Efficient, safe and convenient electric space and water heating

Transcript of Redring Powerstream Electric Flow Boilers · Radiators or floor heating system. TA Plumbing Schemes...

Page 1: Redring Powerstream Electric Flow Boilers · Radiators or floor heating system. TA Plumbing Schemes Powerstream Ascari Heating and domestic hot water Redring recommend to use a direct

Redring Powerstream Electric Flow BoilersEfficient, safe and convenient electric space and water heating

Page 2: Redring Powerstream Electric Flow Boilers · Radiators or floor heating system. TA Plumbing Schemes Powerstream Ascari Heating and domestic hot water Redring recommend to use a direct

Stylishand electric

Redring Electric Flow Boilers Efficient, safe and convenient electric space and water heating

Electric flow boilersRedring electric flow boilers provide wet central heating (and domestic hot waterif required) and are ideal for homes and light commercial premises.They are ideal for use in areas with no mains gas supply and offer the convenience of electric heating combinedwith the comfort and controllability of conventional central heating. They can also be installed in place of boilersusing oil, bottled gas or solid fuel or as an alternative to electric storage heating.

Powerstream boilers are suitable for use with sealed or open vented heating systems and with underfloor heating.

They require no external flue and are easily fitted in confined spaces such as kitchen cupboards or airingcupboards without an external wall. They are 99% efficient and users benefit from the fact that they require noannual servicing or safety check.

When supplied with electricity from renewable sources on a ‘green’ tariff they provide a totally sustainable sourceof heating and hot water.

Page 3: Redring Powerstream Electric Flow Boilers · Radiators or floor heating system. TA Plumbing Schemes Powerstream Ascari Heating and domestic hot water Redring recommend to use a direct

www.redring.co.uk 3

Redring offers two stylish electric Powerstream flow boilermodels to meet a wide range of requirements.

Key Features: Powerstream Ascari• Integral circulation pump and expansion vessel

• Auto-adaptability - minimising energy input,smoothes temp. variation of the home and on/off cycling of the boiler

• Suitable for sealed and open vented systems,with radiators or underfloor heating

• Choice from 12, 8, 6 or 4kW on installation

• Compact design - fits into most spaces(including kitchen cupboards)

• Low maintenance - no requirement for annualservice or safety check (5 year check)

• Near silent operation

• Selectable heating system water temperature,21°C - 80°C - allows low energy setting of heating

• Cast iron engine for thermal stability

• Ideal for well insulated properties of up to 80m2

• 5 litre water storage, for rapid response

• X years guarantee

Key Features: Powerstream Professional• 7 models are available with different kW ratings

(2kW - 12kW)

• Compact design - fits into most spaces(including kitchen cupboards)

• Solid state technology for long-life

• No moving parts maximum reliability

• Minimal service and maintenance costs

• Suitable for sealed and open vented systemswith radiators or underfloor heating

• Uses standard radiators, programmer, pump,room stat and thermostatic radiator valves

• Thermostatic range 30°C to 55°C (underfloor)or 55°C to 80°C (central heating)

• External circulation pump and expansionvessel required

• X years guarantee

Logic Certification

Redring supports installer training throughLogic Certification - a UKAS accredited bodyable to offer certification services under theAccredited Certification Scheme (ACS)through a network of approved training andassessment centres around the UK.

Logic Certification has developed specific courses onthe installation of Redring Powerstream electric flowboilers and also provides more general training inplumbing and electrical installation and commissioning.

For details, and to find a training and assessment centrenear you, visit www.logiccertification.com

Page 4: Redring Powerstream Electric Flow Boilers · Radiators or floor heating system. TA Plumbing Schemes Powerstream Ascari Heating and domestic hot water Redring recommend to use a direct

Redring Powerstream AscariWhen it comes to style and performance, the Powerstream Ascari electric boilerleads the field.By incorporating an integral circulation pump and expansion vessel in the one unit, the Powerstream Ascari looksincredibly stylish and can be installed on display on a wall or in a kitchen cupboard.

It has a sophisticated control system which maximises energy efficiency at 99% by minimising energy inputand on/off cycling of the boiler. The built in 5-litre hot water storage tank also allows for a rapid response tochanging demands.

The Powerstream Ascari is an advanced ‘one fits all’ electric boiler solution as the kW rating of the one model canbe configured from 4 to 12kW’s depending on your requirements. The Powerstream Ascari also comes completewith a soft touch control panel and LED digital display that provides the user with information on the boiler statusand allows for the programming of many functions quickly and easily.

Suitable for use with a wide range of different heating systems, the Powerstream Ascari can provide a water outputtemperatures from 21OC to 80OC – perfect for underfloor heating and standard radiators. You can even keep yourexisting thermostatic radiator valves, room thermostats and programmers to provide central heating that gives highlevels of comfort and control.

Redring Electric Flow Boilers Efficient, safe and convenient electric space and water heating

Simple to usecontrols with digitalLED display

Page 5: Redring Powerstream Electric Flow Boilers · Radiators or floor heating system. TA Plumbing Schemes Powerstream Ascari Heating and domestic hot water Redring recommend to use a direct

www.redring.co.uk 5

Intelligent ControlThe Powerstream Ascari boiler has been designed to provide the highest temperature stability and energyconsumption possible from an electric boiler. Its 5 litre storage and high thermal mass reduce system cooling,while its electronic temperature and auto-adaptability function keep the room at a stable temperature using theleast amount of electrical energy.

The optional outside temperature sensor allows the boiler to quickly adapt to the external temperatures,increasing heat output on cooler days and reducing energy on warmer days, keeping temperature and energycompletely under control.

Running CostsThe Powerstream Ascari boiler is fitted with an auto-adaptability function that operates the central heating systemaccording to the heat characteristics of the property, minimising energy consumption and running costs. TheAscari is designed for use with extended hours off-peak tariffs. Please ask your energy supplier for details ofoptimum tariffs.

1 Lorem ipsum dolor sit amet

2 Aenean cursus hendrerit nibh

3 Duis risus tortor

4 Proin accumsan sem aliquet enim

5 Nunc tempor nunc sed sem cursus

6 Proin rhoncus nulla at elit ultrices

7 Nunc urna urna

8 Pellentesque viverra

2

1

3

4

6

5

7

8

1 Boiler operating LED

2 Decrease system temperature command

3 Heating circuit waterpressure display (bar)

4 On/off command

5 Temperature display heatingwater (in °C)

6 Increase system temperature command

7 Heating temperature command

8 Operating mode selector

Control Panel Inside the Powerstream Ascari

5

6

7

3

2

1

4

Page 6: Redring Powerstream Electric Flow Boilers · Radiators or floor heating system. TA Plumbing Schemes Powerstream Ascari Heating and domestic hot water Redring recommend to use a direct

Redring Powerstream ProfessionalOur entry level electric flow boiler is the 99% efficient and excellent valuePowerstream Professional.Depending on your property size and heating system, you can choose the correct Powerstream Professional tomeet your needs as there are seven models available in the range – with kW ratings from 2 to 12kW’s.

Suitable for use with a wide range of different heating systems, all Powerstream Professional models can provide awater output temperatures from 30OC to 90OC, meaning they can be combined with underfloor heating andstandard radiators. You can even keep your existing thermostatic radiator valves, room thermostats andprogrammers to provide central heating that gives high levels of comfort and control.

All Powerstream Professional boilers require an external pump and expansion vessel to be fitted as part ofthe installation, which makes them ideal for ‘out of sight’ installations – for example in an airing cupboardor utility room.

Redring Electric Flow Boilers Efficient, safe and convenient electric space and water heating

Efficientand excellentvalue

Page 7: Redring Powerstream Electric Flow Boilers · Radiators or floor heating system. TA Plumbing Schemes Powerstream Ascari Heating and domestic hot water Redring recommend to use a direct

www.redring.co.uk 5

4

5

3

2

1

1 Lorem ipsum dolor sit amet

2 Aenean cursus hendrerit nibh

3 Duis risus tortor

4 Proin accumsan sem aliquet enim

5 Nunc tempor nunc sed sem cursus

6 Proin rhoncus nulla at elit ultrices

7 Nunc urna urna

8 Pellentesque viverra

SUPPLY

CALL

ALARM

TEMP

1

2

3

4

5

1 Supply: Green when power is connectedto boiler (on all the time)

2 Call: Green when heat is being demanded (i.e. the room or hot water requires heating). Red indicates there is a fault

3 Four orange lights showing the level being supplied Level is set automatically by the boiler according to conditions(1 light is min. 4 lights is max)

4 Use the dial to set the maximum boiler temperature (the room and hot water temperatures are usually set by separate controls elsewhere in the property)

5 Alarm: Red indicates that the boiler has overheated (An internal cut-out requires ressetting by the installer)

Control Panel Inside the PowerstreamProfessional

Page 8: Redring Powerstream Electric Flow Boilers · Radiators or floor heating system. TA Plumbing Schemes Powerstream Ascari Heating and domestic hot water Redring recommend to use a direct

Redring Electric Flow Boilers Efficient, safe and convenient electric space and water heating

Dimensions and ApplicationPowerstream Ascari

TechnicalFilling LoopThe Powerstream Ascari is not fitted with a filling loop. Any fillingloop being fitted should comply with the Water Supply (waterfittings) Regulations 1999 Section G24.1 and G24.2. A filling loopshould be fitted at some point to allow the CH system to be filled.

Parallel OperationFor larger properties, multiple boilers may be installed in parallel.

Hot Water StorageAsk for the Redring Aqualoy LWSS 2304 Duplex Stainless Steelwater storage heaters that provide effective, fast and safe hotwater for baths, showers and other domestic appliances aroundany property. For use with direct and indirect heating applicationsthe Aqualoy LWSS cylinders are a high quality vessel employingthe best in tig welding technology, the LWSS range also featureshigh flow rates and energy efficient insulation.

Technical SpecificationMaximum power 4-12kW I Includes 8 litre expansion vessel,3bar pressure relief valve and 3-speed pump for quick easyinstall I 7-segment digital displays of temperature and pressure IGraduated power on/off reduces instantaneous loads IFrost protection 5°C minimum system temperature I 5 litre waterstorage I Pump protection, prevents pump sticking I Stainlesssteel elements I Operating pressure 0.5bar - 3bar I Top or bottomcable entry.

ElectricalThe Powerstream Ascari should be permanently connectedto the electrical supply through a double linked switch withminimum breaking capacity for the loading. All wiring should beinstalled to conform to the current edition of the IEE WiringRegulations.

620m

m

405mm

300m

m10

0

280mm

10 10

RSolar Panel

Heating Output

Heating Input

Did you know?Powerstream Ascari and PowerstreamProfessional electric flow boilers may also beused to supplement alternative energy systems(such as solar thermal heating) to maintainwater temperature when the alternative energysystem cannot meet the total heat demand.

Complementing an alternative energy systemTo maintain heating temperature whenalternative energy source cannot supplyenough heating.

Powerstream Ascarior PowerstreamProfessional

Product Range

Product Reference Short Code Cat. No

Powerstream Ascari PSA12 4555186

*Building Regulations apply.

Page 9: Redring Powerstream Electric Flow Boilers · Radiators or floor heating system. TA Plumbing Schemes Powerstream Ascari Heating and domestic hot water Redring recommend to use a direct

www.redring.co.uk 7

Heating onlyRadiators or floor heating system.

TA

Plumbing SchemesPowerstream Ascari

Heating and domestic hot waterRedring recommend to use a direct electric unvented cylinder for the production and storage of the hot water as this is cheaper than an indirect cylinder,requires less plumbing (pipes and valves) and is more thermally efficient.

When using the boiler for unvented hot water and heating, the two-port motorised valve should be inserted in the flow from the boiler.A Differential Pressure Valve should be connected between the flow and return at a point between the boiler and the two-port motorised valve.

Hot WaterOutlet

Room Thermostat

Air Bleeders

3 PortDiverterValve

Two Port Valve

DifferentialPressureValve

CylinderThermostat

3 SpeedPump

Switched Live

8 LitreExpansionVessel

3 Bar PressureRelief Valve

or

Man

ifold

Underfloor Heating

Key Programmer and Room Thermostat Water Pump Regulator

AirBleeders

Page 10: Redring Powerstream Electric Flow Boilers · Radiators or floor heating system. TA Plumbing Schemes Powerstream Ascari Heating and domestic hot water Redring recommend to use a direct

Redring Electric Flow Boilers Efficient, safe and convenient electric space and water heating

Dimensions and ApplicationPowerstream Professional

RSolar Panel

Heating Output

Heating Input

Did you know?Powerstream Ascari and PowerstreamProfessional electric flow boilers may also beused to supplement alternative energy systems(such as solar thermal heating) to maintainwater temperature when the alternative energysystem cannot meet the total heat demand.

Complementing an alternative energy systemTo maintain heating temperature whenalternative energy source cannot supplyenough heating.

Powerstream Ascarior PowerstreamProfessional

Product Range

Product Reference Short Code Cat. No

Powerstream Pro 2kW RFB2 45670202Powerstream Pro 4kW RFB4 45670204Powerstream Pro 6kW RFB6 45670206Powerstream Pro 7.5kW RFB75 45670207Powerstream Pro 9kW RFB9 45670209Powerstream Pro 10.5kW RFB105 45670210Powerstream Pro 12kW RFB12 45670212*Building Regulations apply.

Boiler Temp. BTU kW loading Cable size Fuse ratingvariant range output @ 230-240V guide guide

RFB2 30 - 80 6830 1.8 - 2 1.5mm2 13 AmpsRFB4 30 - 80 13660 3.7 - 4 2.5 / 4mm2 20 AmpsRFB6 30 - 80 20490 5.5 - 6 4mm2 30 AmpsRFB75 30 - 80 25613 6.9 - 7.5 4 / 6mm2 35 - 40 AmpsRFB9 30 - 80 30735 8.3 - 9 6 / 10mm2 40 - 45 AmpsRFB105 30 - 80 35860 9.6 - 10.5 6 / 10mm2 45 AmpsRFB12 30 - 80 40980 11 - 12 10mm2 50 Amps

Selection Guide (Based on NHBC guidelines1)

Property Max. floor area Space Heating only2

Type (m2/ft2) New Build Older properties

1 room bedsit 20 / 200 RFB2 RFB42 room flat 40 / 400 RFB4 RFB61 bed house 80 / 800 RFB6 RFB1052 bed house 100 / 1000 RFB6 RFB123 bed house 130 / 1400 RFB9 n/a4 bed house 150 / 1600 RFB9 n/a5 bed house 190 / 2000 RFB12 n/a

NB 1 In broad terms, stipulates minimum room temperatures and recovery times for typical hot water draw-offs 2 Based on average space heating requirement of 45 W/m2

(New Build), 90W/m2 (Older properties) 3 Includes requirement for a complete tank full recovery time of less than 3 hours.

396m

m

69 O

utle

t

49 In

let

386mm

238mm

86

Boiler sizingPlease consult your installer/heating engineer/designer as to thecorrect size of the Powerstream Professional boiler. Size of theproperty, the insulation properties of the building itself, the localand seasonal weather conditions and exactly what the boiler willbe required to heat, eg: heating and/or hot water will need to beconsidered. To discuss individual delivery and designrequirements or for help with making your selection please call:Technical - 08709 000430or email: Design - [email protected]

Property Space Heating & Indirect Hot Water3

Type Tank (l) Wash New Build Older properties

1 room bedsit 50 1 shower RFB4 RFB62 room flat 115 1 bath RFB75 RFB91 bed house 115 1 bath RFB9 n/a2 bed house 115 1 bath RFB105 n/a3 bed house 115 1 bath RFB12 n/a4 bed house 140 1 bath RFB12 n/a5 bed house 200 2 baths n/a n/a

Page 11: Redring Powerstream Electric Flow Boilers · Radiators or floor heating system. TA Plumbing Schemes Powerstream Ascari Heating and domestic hot water Redring recommend to use a direct

www.redring.co.uk 7

TechnicalPowerstream Professional

For Heating only, with Directdomestic hot water cylinder

For Heating and domestic hot water & Indirect hot water cylinder

For Underfloor Heating system

S Plan System Y Plan System

* Expansion kit not required on a vented system

Hot Water StorageAsk for the Redring Aqualoy LWSS 2304 Duplex Stainless Steel water storage heaters that provide effective, fast and safe hot water forbaths, showers and other domestic appliances around any property. For use with direct and indirect heating applications the AqualoyLWSS cylinders are a high quality vessel employing the best in tig welding technology, the LWSS range also features high flow ratesand energy efficient insulation.

NBhe Redring Powerstream Professional flow boiler is ideal for providing water to a domestic /light commercial wet centralheating system. Where it is intended for use to provide hot water as well, it may be that an alternative direct source of heat is required,eg: immersion heater. This is to ensure compliance with NHBC guidelines and to provide hot water at all times.

NB2The Redring Powerstream Professional flow boiler requires fitment of a circulating pump for underfloor and central heatingapplications. In the case of unvented applications an expansion kit will be required. UK manufactured in a BS EN ISO 9001:2000registered factory.

Technical SpecificationThermostatic temperature range 30°C to 55°C (underfloor) or 55°C to 80°C (central heating) I UK manufactured in a BS EN ISO9001:2000 registered factory.

Page 12: Redring Powerstream Electric Flow Boilers · Radiators or floor heating system. TA Plumbing Schemes Powerstream Ascari Heating and domestic hot water Redring recommend to use a direct

Applied Energy Products LtdMorley WayPeterboroughPE2 9JJ

t +44 (0) 844 372 7761f +44 (0) 844 372 [email protected]

www.youtube.com/user/redringsolutions

www.twitter.com/redringsolution

R043 April 2010

All Redring products, unless otherwise stated, are covered by a full parts and labour guarantee for 1 year from the date of purchase, so should the product becomefaulty within the guarantee period, it will be replaced with a new product or repaired by our service engineers, totally free of charge.

Redring reserve the right to alter product specification or appearance without prior notice. All finishes in the brochure are as accurate as printing processes allow.

04/2010 Applied Energy Products. All rights reserved

UK SalesSales Hotline 0844 372 7750Sales Fax 0844 372 7760

Technical ServicesTechline 0844 372 7766Techfax 0844 372 7767

International SalesRedring is a great British brand in every sense of theword. It is also a world leader in electric heating and hot water demanded in over twenty countries worldwide.Redring has achieved this by taking into considerationglobal market requirements and ensuring products aredeveloped to meet these needs, as well as developingproducts for specific countries and regions, taking intoconsideration approvals, electrical supply and climate.

For further details call:Sales Hotline +44 (0) 1733 456789Sales Fax +44 (0) 1733 456727