Recognition manual 2014 issue 8
description
Transcript of Recognition manual 2014 issue 8
June 2014 – Issue 8
This guide is designed as an aid to recognising component parts andinstalling within Superdrug Pharmacy and associated areas
It is important that this guide is used only in accordance withSuperdrug’s site specific layout drawing
Recognition Manual 2014
Manual Contents
Delivery documentation Pages 2-3
Dispensary Pages 4-30• Contents Page 4
Consultation Room Pages 31-44Consultation Room Pages 31-44• Contents Page 31
Nurses Room Pages 45-59• Contents Page 45
Addicts Area Pages 60-67•Contents Page 60
MDS Room Pages 68-78•Contents Page 68
Page 1Recognition Manual 2014
Equipment Receipt
On receipt of the equipment thedriver will present a copy of thedelivery note which will recordall component parts deliveredin consignment.
It will also show, under“pending” any equipment to“pending” any equipment tofollow.
Delivery Note
Page 2Recognition Manual 2014
PALLET CONTENTS SHEET
Job Number and Store Name
456-055867
Looking forSpecific Items
Delivery To SUPERDRUG at :
37 High Street
Town
County
Post Code
Job Ref. Client Delivery Date
Each pallet delivered will have apallet contents sheet stuck topolythene packaging.
This sheet lists only what isincluded on the pallet andenables specific parts to befound more quickly. Job Ref. Client Delivery Date
10699 01/02/03
PALLET SIZE _______ PALLET 3_______OF_____12___
QTY SUPERDRUG Part No. Cardinal Part No. DESCRIPTION
1 D500BH C6930-00 Bottle Hopper
found more quickly.
Some pallets may have severalparts packed upon it especiallyif they are small.
Retain all pallet sheets forfuture reference untilconsignment has beenunpacked and checked off. 1 D500BH C6930-00 Bottle Hopperunpacked and checked off.
PICKED/PACKED BY ___________________________ DATE ___________________
CHECKED BY _________________________________ DATE ___________________
Pallet Contents Sheet
Page 3Recognition Manual 2014
Dispensary Contents
Part no. Description Page
Typical overview part 1 5Typical overview part 2 6CDC500 Controlled Drugs Cabinet 11CDC760 Controlled Drugs Cabinet 11CDC570 Controlled Drugs Cabinet 11D00BE Bookends 7
Part no. Description Page
D600TEP Tall End Panel 19D650TBC Tall Boxed Corner 20D760AZE A-Z Medicine Storage Extension Module 21, 22D760AZS A-Z Medicine Storage Starter Module 21, 22D760FSE Finished Scripts Extension Module 23, 24D760FSS Finished Scripts Starter Module 23, 24D00BE Bookends 7
D00CM Conical Measure Holder 9D00PS Paper Shredder 25D00RXC RX Cupboard 30D00SBW Splash Back Wall Unit 9D400BN Bin Cupboard inc PVC bin 10D500BH Bottle / Carton Hopper 12D500BSU Bottle Rack & Sink Unit 13D500DP Doop Unit Small 14D500OP Open Shelf Unit 15
D760FSS Finished Scripts Starter Module 23, 24D760UEC Universal End Drawer Cover 24D900NB Notice Board 25D1000ASS Adjustable Spur MFC Shelves 250 & 300mm 7,8D1000DP Doop Unit Large 26D1000GW Grey Worktop (Pill Accuracy Check) 27D1000OP Open shelf unit 28D1020COP Corner Open Shelf Unit 29D1500EM Ergo Mat 25D3000WW White Worktop 27D500OP Open Shelf Unit 15
D500RX Prescription Storage 16D550UBC Under Worktop Boxed Corner 17D550UEP Under Worktop End Panel 17D600IT IT Unit 18
D3000WW White Worktop 27DCN0B Waste Bin 10DCN0WHS Wall Mounted Hand Sanitiser 9DCN0WPT Wall Mounted Paper Towel Dispenser 9
Page 4Recognition Manual 2014
D1
00
0G
W
D3
00
0W
W
D1
00
0A
SS
D3
00
0W
W
D5
00
RX
D5
00
OP
D4
00
BN
D6
00
IT
D5
00
BH
D1
50
0EM
CD
C5
00
D6
50
TBC
D600TEP
D4
00
BN
Typical Dispensary OverviewPlease refer to Superdrug site specific layout drawing for exact configuration of units
Page 5
D5
00
OP
D4
00
BN
D5
00
BH
D1
50
0EM
D6
50
TBC
Recognition Manual 2014
D4
00
BN
D3
00
0W
W
Site specific lockable gate in white MFC.Please refer to Project Manager for details
D1000GW
D3
00
0W
W
D7
60
AZE
D7
60
AZS
D7
60
FSS
D6
50
TBC
D7
60
AZE
D7
60
AZE
D7
60
AZE
Typical Dispensary OverviewPlease refer to Superdrug site specific layout drawing for exact configuration of units
Page 6
D7
60
AZE
D7
60
AZS
D7
60
FSS
D6
50
TBC
Recognition Manual 2014
D7
60
AZE
D7
60
AZE
D7
60
AZE
Adjustable Spur MFC Shelves
Critical Dimensions990(w) x 250(d) x18(h) mm per shelf990(w) x 250(d) x18(h) mm per shelfSent to site as a set of 5no shelves,2no 710mm spur uprights & 5nopairs of 200mm brackets.
Note:- A deeper 300mm shelf maybe specified for the dispensary“back of house” area and shouldbe fixed in accordance with thelayout drawing.
710mm
layout drawing.
D00BEIf Bookends are specifiedleave loose on spurshelves for use bypharmacy team.
Recognition Manual 2014 Page 7
Part no D00BE - BookendsPart no D1000ASS - Adjustable Spur MFC Shelves
1234566789
1011121314151516171819202122
Installation Detail•Set Spur 150mm above the worktopto allow space for low level (90mm)electrical trunking.•Set low level trunking flush withworktop to allow a 60mm gapbetween top of trunking and the 90mm electrical
150mm fromworktop tounderside ofbetween top of trunking and the
underside of the bottom spur shelf.•Space brackets as per set out tothe right. Start at the bottom andleave three clear spaces betweenbrackets.•Make allowances for IT Monitorswhen setting out on site.•Use appropriate wall fixings.
90mm electricaltrunking
underside ofspur post
Recognition Manual 2014 Page 8
Part no D1000ASS - Adjustable Spur MFC Shelves
CT34069 Paper Towel Dispenser290(w) x 145(d) x 265(h) mmNB Key to open dispenser isincluded and should be handedto Pharmacy manager.
DCN0WHS Wall MountedHand Sanitiser
156(w) x 96(d) x 265(h) mm
D00SBW – Splash Back Wall unit
Critical Dimensions990(w) x 12(d) x 600(h) mm
Installation Detail•Use appropriate fixings or gripfill to fix splash backabove bottle rack & sink unit.•Seal joint with white silicon.
Part no D00CM Conical Measure HolderPart no D00SBW Splash Back Wall Unit D00CM Conical Measure Holder
•Seal joint with white silicon.•Add ancillary items to positions indicated onelevation.
Part no D00SBW Splash Back Wall UnitPart no DCN0WHS Wall Mounted Hand SanitiserPart no DCN0WPT Wall Mounted Paper Towel Dispenser
Recognition Manual 2014
D00CM Conical Measure Holder370(w) x 150(d) x 200(h) mm
Page 9
910mm
Critical Dimensions400(w) x 520(d) x 920(h) mm
Installation Detail
•Ensure unit is level usingadjustable feet.•Use appropriate fixings to fixthrough to neighbouring unit.
and to underside of worktop.•A void to rear of unit and wall
Capacity: 39 LitresDimensions: 380(w) x 280(d) x500(h) mm
520mm400mm
Part no. D400BN Bin Cupboard including pvc binPart no. DCN0B Waste Bin
Recognition Manual 2014
•A void to rear of unit and wallallows for plumbing etc.
Page 10
500(h) mm
N.B. Cabinets are only to be fixed to concrete floor or structural wall with rag bolts.Where the pharmacy is on a raised floor create suitable groundings directly toactual flooring.actual flooring.
CDC500500(w) x 450(d) x 850(h)
CDC570570(w) x 200(d) x 520(h)
CDC760760(w) x 305(d) x 865(h)500(w) x 450(d) x 850(h)
Floor fixed570(w) x 200(d) x 520(h)Wall fixed
760(w) x 305(d) x 865(h)Floor/Wall fixed
The Misuse of Drugs Act stipulates that a safe or cabinet shall be rigidly and securely fixed to a wall or floor by means of atleast two rag bolts each passing through an internal anchor plate of mild steel which is at least 3mm thickness and which has a
surface area of at least 19355 square millimetres.
Part no CDC500 Controlled Drugs CabinetPart no CDC570 Controlled Drugs CabinetPart no CDC760 Controlled Drugs Cabinet
Recognition Manual 2014 Page 11
910mm
Critical Dimensions500(w) x 520(d) x 910(h) mm
NoteTop two drawers havedividers for cartons.
910mm
500(w) x 520(d) x 910(h) mm
Installation Detail•Ensure unit is level usingadjustable feet.•Use appropriate fixings to fixthrough to neighbouring unit.
and to underside of worktop•A void to rear of unit and wallallows for plumbing etc.
520mm500mm
Part no D500BH Bottle / Carton Hopper
allows for plumbing etc.
Recognition Manual 2014 Page 12
Critical Dimensions500(w) x 520(d) x 910(h) mm500(w) x 520(d) x 910(h) mm
910mm
520mm500mm
566mmInstallation Detail•Cut hole in back to allowaccess to plumbing .•Ensure unit is level usingadjustable feet.•Use appropriate fixings to fixthrough to neighbouring unit.
and to underside of worktop.•A void to rear of unit and wall
NoteBottle rack is removable toallow access to waste & waterheater.
Sink SpecUniversally Handed Space Saver -620 x 500 mm.
Tap SpecMixer Elbow tap
520mm566mm
206mm
448mm
Part no D500BSU - Bottle Rack & Sink Unit
Recognition Manual 2014
•A void to rear of unit and wallallows for plumbing etc.
Page 13
Mixer Elbow tap
910mm
Critical Dimensions500(w) x 520(d) x 910(h) mm
Note
Installation Detail
•Ensure unit is level usingadjustable feet.•Use appropriate fixings to fixthrough to neighbouring unit.
and to underside of worktop.•A void to rear of unit and wall
520mm500mm
Part no D500DP - Doop Unit Small
Note1no adjustable shelf toeach unit.
Recognition Manual 2014
•A void to rear of unit and wallallows for plumbing etc.
Page 14
910mm
Critical Dimensions
NoteIncludes 3no adjustableshelves.
Installation Detail•Ensure unit is level usingadjustable feet.•Use appropriate fixings to fixthrough to neighbouring unit.
and to underside of worktop.•A void to rear of unit and wallallows for plumbing etc.
520mm500mm
Part no. D500OP - Open Shelf Unit
Critical Dimensions500(w) x 520(d) x 910(h) mm
Recognition Manual 2014
allows for plumbing etc.
Page 15
910mm
Critical Dimensions500(w) x 520(d) x 910(h) mm
Note•Suited locks to full range, eachdrawer has binning strip withacrylic dividers.•Dividers to three top drawers.
Installation Detail•Ensure unit is level usingadjustable feet.•Use appropriate fixings to fixthrough to neighbouring unit.
and to underside of worktop.•A void to rear of unit and wallallows for plumbing etc.
520mm500mm
Part no. D500RX - Prescription Storage
Recognition Manual 2014
allows for plumbing etc.
Page 16
Critical Dimensions550(w) x18(d) x 920(h) mm
Under Worktop End Panels
Installation Detail•Use top & bottom Uchannel or appropriatefixings to fix to end unit.
920mm
Critical Dimensions550(w) x 550(d) x 920(h) mm
Installation Detail•Use appropriate fixings to fix U channel to underside of
Under Worktop Boxed Corner
550mm
550mm
•Use appropriate fixings to fix U channel to underside ofworktop and floor.•Position first top & bottom U channels 530mm fromwall.•Position second set 550mm from adjacent wall.•Panels are supplied oversized so that they can bescribed to fit.•Slide panels into position and cover front corner withwhite PVC angle trim.
550mm
920mm
Part no. D550UBC - Under Worktop Boxed CornerPart no. D550UEP - Under Worktop End panels
Recognition Manual 2014 Page 17
550mm
910mm
Critical Dimensions
NoteCut out to rear to enablecabling.
Installation Detail•Ensure unit is level usingadjustable feet.•Use appropriate fixings to fixthrough to neighbouring unit.
and to underside of worktop.•Void to rear of unit and wallallows for plumbing etc.
520mm
600mm
Part no. D600IT - IT Unit
Critical Dimensions600(w) x 520(d) x 910(h) mm
Recognition Manual 2014
allows for plumbing etc.
Page 18
D600TEP Tall End Panel
Critical DimensionsCritical Dimensions600(w) x 18(d) x 2100(h) mm
Installation Detail•Panel has pre-drilled holes for fixing to perimeter post.•Use appropriate fixings to fix end panel to perimeterpost.•Use white screw caps to cover any visible screws.•Seal joint to wall with white silicon.
Part no. D600TEP – Tall End Panel
Page 19Recognition Manual 2014
Critical Dimensions650(w) x 650(d) x 2400(h) mm
2400mm
Installation Detail
•Create boxed corner from 50mm x 50mm softwood andwhite MFC panels supplied.•Use appropriate fixings to fit softwood to walls.•Use appropriate fixings to fix panels into position andcover front corner with white PVC angle trim.•Use white screw caps to cover any visible screws.
Part no. D650TBC – Tall Boxed Corner
•Use white screw caps to cover any visible screws.•If ceiling height exceeds 2400mm cut wall batons fromsoftwood provided and fix to wall to take lid.
Recognition Manual 2014 Page 20
650mm650mm
Part no. D760AZS - A-Z Medicine Starter Module
Part no. D760AZE - A-Z Medicine Extension Module
CautionIt is vital that system posts are installed in astraight line, vertical and level and fixed at 2nopoints on each individual post utilising suppliedadjustable wall fixing brackets
Recognition Manual 2014 Page 21
Site specific lockable gate in white MFC.Please refer to Project Manager for details
1. Erect frame of perimeterlegs and tie bars usingM10x50mm bolts, washersand nuts. Use 3no tie barsper module.per module.
The tie bars are handed soensure bar faces front onbrackets.
Do not over tighten.
2. Use adjustable feet to level
3. Use two wall fixingbrackets per upright, at alltimes using appropriatefixings to ensure posts areflush with each other.
Front
2. Use adjustable feet to levelframe.
flush with each other.
Critical Dimensions 760(w) x 610(d) x 2100(h) mm
7. Fit pull out shelves into postsstarting at bottom. The bottom shelfto occupy notches 11 & 13. Leave2no empty notches between eachsubsequent shelf.
6. Slide into position baseplinth drawers.
4. When all of the posts are inposition screw on the baseplinth covers.
5. Hang back panelson to tie bars.
Critical Dimensions 760(w) x 610(d) x 2100(h) mm
Recognition Manual 2014
Part no. D760AZS - A-Z Medicine Starter Module
Part no. D760AZE - A-Z Medicine Extension Module
Page 22
Part no. D760FSS Finished Scripts Starter Module
Part no. D760FSE Finished Scripts Extension Module
CautionIt is vital that system posts are installed in astraight line, vertical and level and fixed at 2nopoints on each individual post utilising suppliedadjustable wall fixing brackets
Page 23Recognition Manual 2014
Site specific lockable gate in white MFC.Please refer to Project Manager for details
1. Build frame as in A-Zmodules but use “L” shapedposts rather than “h” shapedposts.
2. Start at bottom and fit2. Start at bottom and fitdeep drawers into lowestpossible notches.
3. Fit lower pull out shelfinto notch 41 and thenleave 3no. notchesbetween each shelf above.
4. Fit opal acrylic fronts to5no. Pull out shelves.
D760UEC Universal End Drawer Cover1. Use Universal End Drawer cover on proceeding A-Zmodule if Finished Scripts module is part of same run.
Part no. D760FSS Finished Scripts Starter Module
Enablestransition fromA-Z “h” leg toFinished scripts“L” leg.
Critical Dimensions 760(w) x 610(d) x 2100(h) mm
Recognition Manual 2014
Part no. D760FSS Finished Scripts Starter ModulePart no. D760FSE Finished Scripts Extension ModulePart no. D760UEC Universal End Drawer Cover
Page 24
D900NB – 900 x 600mmNotice board to be fixed usingappropriate fixings whereindicated on layout drawing –landscape or portrait.
D1500EMErgo mat to be loose laid asindicated on layout drawing.
D00PSPaper Shredder to be placedwhere indicated on layout
Part no D900NB - Notice BoardPart no D1500EM - Ergo MatPart no D00PS - Paper ShredderRecognition Manual 2014 Page 25
where indicated on layoutdrawing.
910mm
Installation Detail
Critical Dimensions1000(w) x 520(d) x 910(h) mmNote
Installation Detail•Ensure unit is level usingadjustable feet.•Use appropriate fixings to fixthrough to neighbouring unit.
and to underside of worktop.•A void to rear of unit and wallallows for plumbing etc.
520mm
1000mm
Part no D1000DP - Doop Unit Large
Note1no adjustable shelf.
Recognition Manual 2014 Page 26
Accuracy Checking Area Worktop
The accuracy checking area is a grey worktop
Critical Dimensions1000(w) x 600(d) x 30(h) mm
The accuracy checking area is a grey worktop
Critical Dimensions3000(w) x 600(d) x30(h) mm
White worktops
Installation Detail•Cut to appropriate length as required on site.•Exposed ends should always overrun 25mm.•Edge all exposed ends.•Create a masons mitre for all corner joints.•Use 3no work top connectors to all joints.•Use appropriate fixings to fix top to unitsunderneath.
3000(w) x 600(d) x30(h) mm
Installation Detail•Where indicated on layout drawing fit grey worktop.•Exposed ends should always overrun 25mm.•Edge all exposed ends.•Create a masons mitre for any corner joints.•Use 3no work top connectors to all joints.•Use appropriate fixings to fix top to units underneath.•Seal joint to wall with white silicon.
Part no D1000GW - Grey WorktopPart no D3000WW - White Worktop
underneath.•Seal joint to wall with white silicon.
Page 27Recognition Manual 2014
910mm
NoteIncludes 3no adjustableshelves.
Installation Detail•Ensure unit is level usingadjustable feet.•Use appropriate fixings to fixthrough to neighbouring unit.
and to underside of worktop.•A void to rear of unit and wallallows for plumbing etc. Critical Dimensions
520mm
1000mm
allows for plumbing etc.
Part no. D1000OP - Open Shelf Unit
Critical Dimensions1000(w) x 520(d) x 910(h) mm
Page 28Recognition Manual 2014
Critical Dimensions1020(w) x 1020(d) x 910(h) mm1020(w) x 1020(d) x 910(h) mm
Installation Detail•Ensure unit is level usingadjustable feet.•Use appropriate fixings to fixthrough to neighbouring unit.
and to underside of worktop.and to underside of worktop.•A void to rear of unit and wallallows for plumbing etc.
910mm
1020mm1020mm
Part no. D1020COP - Corner Open Shelf Unit
Page 29Recognition Manual 2014
1020mm
Recognition Manual 2014 Page 30
Part no. D00RXC - RX Cupboard
Consultation Room Contents
Part no. Description Page
Typical overview 32CN00LH Leaflet Holder with Magnetic Panel 33CN377DDP Drop Down Desk c/w PC Housing 34CN500DCU Drawer & Cupboard Unit 35CN500LSC Lockable Storage Cupboard 36CN500PFU Printer Shelf (Pull out) & Filing Unit 37
Part no. Description Page
CN00CS Child Seat 43CN00HM Height Measure – Wall mounted 43CN00MT Mixer Tap 42CN00S Sink 42CN00SF Sharps Flap 42CN00WA Chair without Arms – Green 43CN500PFU Printer Shelf (Pull out) & Filing Unit 37
CN500WLH Wall Mounted Cupboard L/H 38CN500WOS Wall Mounted Open Shelves 39CN500WRH Wall Mounted Cupboard R/H 38CN926WD Consultation Room Door 40CN2000SB Brushed Laminate Splash Back 41CN2000PCB Plinth Cover to Cons Room Base Units 42CN00A Chair with Arms – Green 43
CN00WA Chair without Arms – Green 43CN00WGD Wall Mounted Glove Dispenser 41CN00WS Weighing Scales 43D3000WW White Worktop 42DCN0B Waste Bin 35DCN0WHS Wall Mounted Hand Sanitiser 41DCN0WPT Wall Mounted Paper Towel Dispenser 41AA500AH Addicts Hatch 44
Page 31Recognition Manual 2014
CN
50
0W
RH
CN
50
0P
FU
CN
50
0W
OS
CN
50
0W
LH
CN
50
0W
LH
CN
00
LH
CN
50
0W
RH
CN
50
0P
FU
CN
50
0W
OS
CN
50
0W
LH
CN
50
0W
LH
CN00SF
AA500AH
CN
20
00
SB
CN00SF
CN
50
0LS
C
CN
20
00
SB
CN377DDP
D3
00
0W
W
CN
20
00
PC
B
CN
50
0D
CU
Contractors must ensure that all partition wallsthat make up a consultation room have adequate
sound provision. Fill void with Rockwool orsimilar material. Also lay above suspended
Typical Consultation Room OverviewPlease refer to Superdrug site specific layout drawing for exact configuration of units
Page 32Recognition Manual 2014
similar material. Also lay above suspendedceiling but consult with Project Manager first to
check that there are no asbestos issues
Critical Dimensions1000(w) x 5(d) x 800(h) mm
Installation Detail•Use appropriate fixings to fixto wall as indicated on layoutSuperdrug drawing.
Recognition Manual 2014 Page 33
Part no CN00LH Leaflet Holder with magnetic panel
Superdrug drawing.
Power and data sockets to befixed inside desk
750mm
Critical Dimensions600(w) x 377(d) x 750(h) mm
PANIC ALARM & RESETBUTTON - Site electrician toposition BOTH inside top cornerof unit
377mm600mm
Closedend
Openend
600(w) x 377(d) x 750(h) mm
Installation Detail•Position top to ensure openend faces wall units and closedend faces patient.•Use appropriate fixings to fixto wall.•To change handing remove topand rotate 180*.
of unit
Part no CN377DDP Drop Down Desk
and rotate 180*.
Recognition Manual 2014 Page 34
Critical Dimensions500(w) x 520(d) x 910(h) mm
910mm
Installation Detail•Level using adjustable feet.•Use appropriate fixings to fixthrough to wall & neighbouringunits.
Cupboard can beused for Clinical
520mm
Part no CN500DCU Drawer & Cupboard Unit
Recognition Manual 2014
used for Clinicalbin.
Page 35
500mm
910mm
Critical Dimensions500(w) x 520(d) x910(h) mm
Installation Detail
•Level using adjustable feet.
520mm500mm
•Level using adjustable feet.•Use appropriate fixings to fixthrough to wall & neighbouringunits.•If Needle Exchange chute isrequired cut worktop usingchute as a template.•For Sharps Flap specificationplease see page 34.
•Waste Bin to stand inside one of thelockable storage cupboards.•Yellow Needle bin supplied by LocalAuthority.
CN500LSC Lockable Storage CupboardDCN0B Waste Bin
Recognition Manual 2014 Page 36
Back of unit is open to allow accessto power and data sockets.to power and data sockets.
500mm
910mm
Critical Dimensions
Installation Detail•Level using adjustable feet.•Use appropriate fixings to fixthrough to wall & neighbouringunits. 520mm
Part no CN500PFU mm Printer & File Unit
Critical Dimensions500(w) x 520(d) x 910(h) mm
Recognition Manual 2014 Page 37
600mm
350mm
600mm
500mm
Critical Dimensions600(h) x 500(w) x350(d) mmInstallation Detail
•All wall units should be fixed 550mm abovefinished worktop to allow for splashback.•Use appropriate fixings to fix to wall .•Use white screw caps to cover any visiblescrews.
Critical Dimensions500(w) x 350(d) 600(h) mm
Part no CN500WLH Wall Cupboard L/HPart no CN500WRH Wall Cupboard R/H
Recognition Manual 2014 Page 38
600mm
Installation Detail•All wall units should be fixed 550mm abovefinished worktop to allow for splashback.•Use appropriate fixings to fix to wall .•Use white screw caps to cover any visiblescrews.
Critical Dimensions500(w) x 350(d) 600(h) mm 350mm
500mm
Part no CN500WOS Wall Mounted Open Shelves
Recognition Manual 2014
screws.
Page 39
Cross logo suppliedby signage contractor
Critical DimensionsCritical Dimensions926(w) x 45(d) x 2040(h) mm
Installation Detail
•Sent to site without blind orhinges attached (but supplied)to enable door to be handed onsite.site.
•Door is supplied withundercoat. Top coat must beadded on site.
•Fix blind to rear of door usingappropriate fixings.
•Fix door hook to rear of door
Part no CN926WD Consultation Room Door
•Fix door hook to rear of doorcentralised at 1600mm high.
Recognition Manual 2014 Page 40
Splash Back
DCN0WPT Paper TowelDispenser 290(w) x 145(d) x265(h) mmNB Key to open dispenser isincluded and should be handed
DCN0WHS Wall MountedHand Sanitiser
156(w) x 96(d) x 265(h) mm
Critical Dimensions2000(w) x 18(d) x 550(h) mm
Installation Detail•Use appropriate fixings orgripfill to fix splash back.
Splash BackPre Laid Brushed AluminiumMDF.
included and should be handedto Pharmacy manager.
Part no CN2000SB Splash Back
gripfill to fix splash back.•Add ancillary items to positionsindicated on elevation.•Please ensure that there isenough clearance above toweldispenser to allow with openingkey.
CN00WGD Dispenser 270(w) x95(d) x 100mm (h)
Part no CN2000SB Splash BackPart no CN00WGD Wall Mounted Glove DispenserPart no DCN0WHS Wall Mounted Hand SanitiserPart no DCN0WPT Paper Towel DispenserRecognition Manual 2014 Page 41
Ensure cables to pc arecarried though partitionwalls
Installation Detail
•Cut worktop to length.•Edge any exposed ends.•Fit to top of base units using appropriate fixings.•Fit to top of base units using appropriate fixings.•Cut hole for sink and mixer tap as indicated on layoutdrawing.•Cut hole for Sharps flap if required.•Fix plinth to base units using gripfill or appropriatefixings.
Part no D3000WW WorktopPart no CN00S Sink
CN2000PCBBrushed Aluminium Laminate
CN00SF Sharps Flap fittingdetail
Part no CN00S SinkPart no CN00MT Mixer TapPart no CN00SF Sharps FlapPart no CN2000PCB Plinth to Base Unit
Brushed Aluminium Laminatefaced mdf plinth 2000(w) x100(h) x 18(d) mm
Page 42Recognition Manual 2014
Installation Detail
•Position all ancillary items as
Part no CN00WA Chair without Arms
•Position all ancillary items asper layout drawing.•Use appropriate fixings to fixheight measurer to wall.
Part no CN00A Chair with ArmsPart no CN00HM Height measurerPart no CN00WS Weighing scalesPart no CN00CS Child Seat
Page 43Recognition Manual 2014
Installation Detail
•Cut opening in partition wall asindicated on layout drawing and addtimber studs and noggins wherenecessary to take hatch fixings.•The bottom of the opening shouldbe 1200mm above floor.be 1200mm above floor.•Insert hatch into opening and useappropriate fixings to secure.•Fit shroud to reverse usingappropriate fixings.
Note•Liaise with electrical contractor toensure cable feed for bell push is
Recognition Manual 2014 Page 44
Part no AA500AH Addicts Hatch
ensure cable feed for bell push isaccessible.
Nurses Room Contents
Part no. Description Page
Typical overview 46CN400LSC Lockable storage cupboard 47CN500DCU Drawer & Cupboard Unit 48CN500LSC Lockable Storage Cupboard 49CN500PFU Printer Shelf (Pull out) & Filing Unit 50CN500WLH Wall Mounted Cupboard L/H 51
Part no. Description Page
CN00LH Leaflet Holder Panel 57CN00WA Chair without Arms – Green 56CN00WGD Wall Mounted Glove Dispenser 54CN00WS Weighing Scales 56D3000WW White Worktop 55DCN0B Waste Bin 49CN500WLH Wall Mounted Cupboard L/H 51
CN500WOS Wall Mounted Open Shelves 52CN500WRH Wall Mounted Cupboard R/H 51CN926WD Consultation Room Door 53CN2000SB Brushed Laminate Splash Back 54CN2000PCB Plinth Cover to Cons Room Base Units 55CN00A Chair with Arms – Green 56CN00CS Child Seat 56CN00HM Height Measure – Wall mounted 56CN00MT Mixer Tap 55
DCN0B Waste Bin 49DCN0WHS Wall Mounted Hand Sanitiser 54DCN0WPT Wall Mounted Paper Towel Dispenser 54N00CC Curtain Cubicle 58N00CCR Curtain Rail 58N00CR Couch Rolls 58N00CWA Nurses Desk Chair with Arms 59N00EC Examination Couch 58N500WM Wall Mirror 59N1200DK Desk to Nurses Room 59CN00MT Mixer Tap 55
CN00S Sink 55CN00SF Sharps Flap 55
N1200DK Desk to Nurses Room 59
Page 45Recognition Manual 2014
CN
92
6W
DC
N9
26
WD
N0
0C
C
N0
0EC
Contractors must ensure that all partition wallsthat make up a consultation room have adequate
sound provision. Fill void with Rockwool orsimilar material. Also lay above suspended
ceiling but consult with Project Manager first tocheck that there are no asbestos issues
Typical Nurses Room OverviewPlease refer to Superdrug site specific layout drawing for exact configuration of units
Page 46Recognition Manual 2014
check that there are no asbestos issues
910mm
Installation Detail
•Level using adjustable feet.
520mm
400mm
Critical Dimensions500(w) x 520(d) x 910(h) mm
•Level using adjustable feet.•Use appropriate fixings to fixthrough to wall & neighbouringunits.•If Needle Exchange chute isrequired cut worktop usingchute as a template.•For Sharps Flap specificationplease see page 34.
•Waste Bin to stand inside one of thelockable storage cupboards.•Yellow Needle bin supplied by LocalAuthority.
CN400LSC Lockable Storage CupboardDCN0B Waste Bin
Recognition Manual 2014
Authority.
Page 47
Critical Dimensions910mm
Critical Dimensions500(w) x 520(d) x 910(h) mm
Installation Detail•Level using adjustable feet.•Use appropriate fixings to fixthrough to wall & neighbouringunits.
Cupboard can beused for Clinicalbin.
Part no CN500DCU Drawer & Cupboard Unit
Recognition Manual 2014 Page 48
520mm500mm
910mm
Critical Dimensions500(w) x 520(d) x 910(h) mmInstallation Detail
•Level using adjustable feet.
520mm500mm
•Level using adjustable feet.•Use appropriate fixings to fixthrough to wall & neighbouringunits.•If Needle Exchange chute isrequired cut worktop usingchute as a template.•For Sharps Flap specificationplease see page 34.
•Waste Bin to stand inside one of thelockable storage cupboards.•Yellow Needle bin supplied by LocalAuthority.
CN500LSC Lockable Storage CupboardDCN0B Waste Bin
Recognition Manual 2014 Page 49
PANIC ALARM and RESET BUTTON-Site electrician to position to inside of
Back of unit is open to allow accessto power and data sockets
Site electrician to position to inside ofpedestal
910mm
Installation Detail•Level using adjustable feet.•Use appropriate fixings to fixthrough to wall & neighbouringunits.
520mm500mm
Part no CN500PFU mm Printer & File Unit
Critical Dimensions500(w) x 520(d) x 910(h) mm
Recognition Manual 2014 Page 50
600mm
Critical Dimensions600(h) x 500(w) x350(d) mm
350mm
600mm
500mm
600(h) x 500(w) x350(d) mm
Installation Detail•All wall units should be fixed 550mm abovefinished worktop to allow for splashback.•Use appropriate fixings to fix to wall .•Use white screw caps to cover any visiblescrews.
Critical Dimensions600(h) x 500(w) x350(d) mm
Part no CN500WLH Wall Cupboard R/HPart no CN500RLH Wall Cupboard L/H
Recognition Manual 2014 Page 51
600mm600mm
Critical Dimensions500(w) x 350(d) x 600(h) mm
Installation Detail•All wall units should be fixed 550mm abovefinished worktop to allow for splashback.•Use appropriate fixings to fix to wall .•Use white screw caps to cover any visiblescrews.
350mm500mm
Part no CN500WOS Wall Mounted Open Shelves
Recognition Manual 2014 Page 52
Cross logo suppliedby signage contractor
Critical DimensionsCritical Dimensions926(w) x 45(d) x 2040(h) mm
Installation Detail
•Sent to site without blind orhinges attached (but supplied)to enable door to be handed onsite.site.
•Door is supplied withundercoat. Top coat must beadded on site.
•Fix blind to rear of door usingappropriate fixings.
•Fix door hook to rear of door
Part no CN926WD Consultation Room Door
•Fix door hook to rear of doorcentralised at 1600mm high.
Recognition Manual 2014 Page 53
Splash Back
DCN0WPT Paper TowelDispenser 290(w) x 145(d) x265(h) mmNB Key to open dispenser isincluded and should be handed
DCN0WHS Wall MountedHand Sanitiser
156(w) x 96(d) x 265(h) mm
Critical Dimensions2000(w) x 18(d) x 550(h) mm
Installation Detail•Use appropriate fixings orgripfill to fix splash back.
Splash BackPre Laid Brushed AluminiumMDF.
included and should be handedto Pharmacy manager.
Part no CN2000SB Splash Back
gripfill to fix splash back.•Add ancillary items to positionsindicated on elevation.•Please ensure that there isenough clearance above toweldispenser to allow with openingkey.
CN00WGD Wall Mounted GloveDispenser 270(w) x 95(d) x100(h) mm
Part no CN2000SB Splash BackPart no CN00WGD Wall Mounted GlovePart no DCN0WHS Wall Mounted Hand SanitiserPart no DCN0WPT Paper Towel DispenserRecognition Manual 2014
100(h) mm
Page 54
Installation Detail
•Cut worktop to length.•Edge any exposed ends.•Fit to top of base units using appropriate fixings.•Fit to top of base units using appropriate fixings.•Cut hole for sink and mixer tap as indicated on layoutdrawing.•Cut hole for Sharps flap if required.•Fix plinth to base units using gripfill or appropriatefixings.
Part no D3000WW WorktopPart no CN00S Sink
CN2000PCBBrushed Aluminium Laminate
CN00SF Sharps Flap fittingdetail.
Part no CN00S SinkPart no CN00MT Mixer TapPart no CN00SF Sharps FlapPart no CN2000PCB Plinth to Base Unit
Brushed Aluminium Laminatefaced mdf plinth 2000(w) x18(d) x100(h) mm
Page 55Recognition Manual 2014
Installation Detail
•Position all ancillary items asper layout drawing.•Use appropriate fixings to fixheight measurer to wall.•Place child seat under bed.
Part no CN00WA Chair without ArmsPart no CN00A Chair with ArmsPart no CN00HM Height MeasurerPart no CN00WS Weighing ScalesPart no CN00CS Child Seat
Page 56Recognition Manual 2014
Critical Dimensions1000(w) x 5(d) x 800(h) mm
Installation Detail•Use appropriate fixings to fixto wall as indicated on layoutSuperdrug drawing.
Recognition Manual 2014 Page 57
Part no CN00LH Leaflet Holder with magnetic panel
Superdrug drawing.
Critical Dimensions1930(w) x 600(d) x 780(h) mm
Part no N00EC Examination CouchPart no N00CR Couch Rolls
Installation Detail
•Fix Curtain rail to ceiling asindicated on layout drawing.
Part no N00CR Couch RollsPart no N00CC Cubicle CurtainPart no N00CR Curtain Rail
Recognition Manual 2014 Page 58
N1200DK Desk to Nurses Room
Critical Dimensions1200(w) x 800(d) x 730(h) mm
N500WM Wall Mirror
N00CWA Nurse DeskChair with Arms.
Critical Dimensions470(w) x 470 (d) x 1300(h) mm
N500WM Wall Mirror500(w) x 1500(h) mm
Installation Detail•Use appropriate fixings to fit mirrorto wall 400mm from the floor.•Use mirror screw caps to coverfixings.
Part no N1200DK Desk to Nurses Room
Recognition Manual 2014 Page 59
Part no N1200DK Desk to Nurses RoomPart no N00CWA Nurse Desk Chair with ArmsPart no N500WM Wall Mirror
Addicts Area Contents
Part no. Description Page
Typical overview 61AA500AH Addicts Hatch 62AA900SD Swing Doors 63D500DP Doop Unit Small 64D550UEP - Under Worktop End panels 65D3000WW - White Worktop 66D3000WW - White Worktop 66CN00SF Sharps Flap 66
Recognition Manual 2014 Page 60
External InternalContractors must ensure that all partition walls
that make up a consultation room have adequatesound provision. Fill void with Rockwool orsimilar material. Also lay above suspended
ceiling but consult with Project Manager first tocheck that there are no asbestos issues
Typical Addicts Area OverviewPlease refer to Superdrug site specific layout drawing for exact configuration of units
Page 61Recognition Manual 2014
check that there are no asbestos issues
Installation Detail
•Cut opening in partition wall asindicated on layout drawing and addtimber studs and noggins wherenecessary to take hatch fixings.•The bottom of the opening shouldbe 1200mm above floor.be 1200mm above floor.•Insert hatch into opening and useappropriate fixings to secure.•Fit shroud to reverse usingappropriate fixings.
Note•Liaise with electrical contractor toensure cable feed for bell push is
Recognition Manual 2014 Page 62
Part no AA500AH Addicts Hatch
ensure cable feed for bell push isaccessible.
Cross logo suppliedby signage contractor
1200
1000
600
Installation Detail
•Create 1m opening in partition wallas indicated on layout drawing.•Secure stiles to frame withappropriate fixings.•Fix swing doors to stiles 600mmabove floor.
Part no AA900SD Swing Doors
Recognition Manual 2014
above floor.
Page 64
2100mm
910mm
1500mm
Installation Detail
•Cut opening in partition wall asindicated on layout drawing.•Position doop unit intoopening with the door facing 520mm
500mm
Critical Dimensions500(w) x 520(d) x 910(h) mm
opening with the door facinginto the dispensary.•Use appropriate fixings tosecure doop unit withinpartition wall.
Recognition Manual 2014 Page 65
Part no D500DP - Doop Unit Small
Note1no adjustable shelf toeach unit.
Under Worktop End Panels
Critical Dimensions550(w) x18(d) x 920(h) mm
Installation Detail•Use top & bottom Uchannel or appropriatefixings to fix to end unit.
NoteCut and scribe piece ofwhite mfc to form frontpanel.
Recognition Manual 2014 Page 66
Part no. D550UEP - Under Worktop End panels
Installation Detail•Cut worktop to length as indicated onSuperdrug layout drawing.•Edge any exposed ends.•Fix to doop unit using appropriate fixings.
Installation Detail•Cut worktop as indicated onSuperdrug layout drawing to take flap.•Flap opens to front.
Recognition Manual 2014 Page 67
Part no D3000WW - White WorktopPart no CN00SF Sharps Flap
MDS Room Contents
Part no. Description Page
Typical overview 69Typical overview 70D500OP - Open Shelf Unit 71D600IT - IT Unit 72D400BN Bin Cupboard including pvc bin 73DCN0B Waste Bin 73DCN0B Waste Bin 73CN500LSC Lockable Storage Cupboard 74CDC500 Controlled Drugs Cabinet 75D1000GW - Grey Worktop 76D3000WW - White Worktop 76D1000ASS - Adjustable Spur MFC Shelves 77D1500EM - Ergo Mat 78D00PS - Paper Shredder 78
Recognition Manual 2014 Page 68
Recognition Manual 2014 Page 69
MDS Room OverviewPlease refer to Superdrug site specific layout drawing for exact configuration of units
Area identified fordossette boxracking
Area identified fordossette boxracking
Lockable cupboardfor confidentialwaste Phone line to
Worktop mountedprinter scanner
Recognition Manual 2014 Page 70
waste Phone line todispensary andoutside line
MDS Room Overview
910mm
Critical Dimensions
NoteIncludes 3no adjustableshelves.
Installation Detail•Ensure unit is level usingadjustable feet.•Use appropriate fixings to fixthrough to neighbouring unit.
and to underside of worktop.•A void to rear of unit and wallallows for plumbing etc.
520mm500mm
Part no. D500OP - Open Shelf Unit
Critical Dimensions500(w) x 520(d) x 910(h) mm
Recognition Manual 2014
allows for plumbing etc.
Page 71
910mm
Critical Dimensions
NoteCut out to rear to enablecabling.
Installation Detail•Ensure unit is level usingadjustable feet.•Use appropriate fixings to fixthrough to neighbouring unit.
and to underside of worktop.•Void to rear of unit and wallallows for plumbing etc.
520mm
600mm
Part no. D600IT - IT Unit
Critical Dimensions600(w) x 520(d) x 910(h) mm
Recognition Manual 2014
allows for plumbing etc.
Page 72
910mm
Critical Dimensions400(w) x 520(d) x 920(h) mm400(w) x 520(d) x 920(h) mm
Installation Detail
•Ensure unit is level usingadjustable feet.•Use appropriate fixings to fixthrough to neighbouring unit.
and to underside of worktop.•A void to rear of unit and wall
Capacity: 39 LitresDimensions: 380(w) x 280(d) x500(h) mm
520mm400mm
Part no. D400BN Bin Cupboard including pvc binPart no. DCN0B Waste Bin
Recognition Manual 2014
•A void to rear of unit and wallallows for plumbing etc.
Page 73
500(h) mm
910mm
Installation Detail
•Level using adjustable feet. 520mm500mm
Critical Dimensions500(w) x 520(d) x 910(h) mm
•Level using adjustable feet.•Use appropriate fixings to fixthrough to wall & neighbouringunits.
520mm500mm
CN500LSC Lockable Storage Cupboard
Recognition Manual 2014 Page 74
N.B. Cabinets are only to be fixed to concrete floor or structural wall with rag bolts.Where the pharmacy is on a raised floor create suitable groundings directly toactual flooring.actual flooring.
The Misuse of Drugs Act stipulates that asafe or cabinet shall be rigidly and securelyfixed to a wall or floor by means of at leastfixed to a wall or floor by means of at least
two rag bolts each passing through aninternal anchor plate of mild steel which is
at least 3mm thickness and which has asurface area of at least 19355 square
millimetres.
CDC500500(w) x 450(d) x 850(h)Floor fixed
Part no CDC500 Controlled Drugs Cabinet
Recognition Manual 2014 Page 75
The accuracy checking areais a grey worktop
Critical Dimensions3000(w) x 600(d) x30(h) mm
Accuracy Checking Area Worktop
Critical Dimensions
White worktops
Installation Detail•Cut to appropriate length as required on site.•Exposed ends should always overrun 25mm.•Edge all exposed ends.•Create a masons mitre for all corner joints.•Use 3no work top connectors to all joints.•Use appropriate fixings to fix top to unitsunderneath.
3000(w) x 600(d) x30(h) mm Critical Dimensions1000(w) x 600(d) x 30(h) mm
Installation Detail•Where indicated on layout drawing fit grey worktop.•Exposed ends should always overrun 25mm.•Edge all exposed ends.•Create a masons mitre for any corner joints.•Use 3no work top connectors to all joints.•Use appropriate fixings to fix top to units underneath.Seal joint to wall with white silicon.
Part no D1000GW - Grey WorktopPart no D3000WW - White Worktop
underneath.•Seal joint to wall with white silicon. •Seal joint to wall with white silicon.
Page 76Recognition Manual 2014
1234566789
1011121314151516171819202122
Installation Detail•Set Spur 150mm above the worktopto allow space for low level (90mm)electrical trunking.•Set low level trunking flush withworktop to allow a 60mm gapbetween top of trunking and the 90mm electrical
150mm fromworktop tounderside ofbetween top of trunking and the
underside of the bottom spur shelf.•Space brackets as per set out tothe right. Start at the bottom andleave three clear spaces betweenbrackets.•Make allowances for IT Monitorswhen setting out on site.•Use appropriate wall fixings.
90mm electricaltrunking
underside ofspur post
Recognition Manual 2014 Page 77
Part no D1000ASS - Adjustable Spur MFC Shelves
D1500EMErgo mat to be loose laid asindicated on layout drawing.
D00PSPaper Shredder to be placedwhere indicated on layoutdrawing.
Part no D1500EM - Ergo MatPart no D00PS - Paper Shredder
Recognition Manual 2014 Page 78
Please address any questions, comments or forPlease address any questions, comments or forinformation on the latest issue in circulation toPharmacy Development.
This is manual issue 8, for information on the latestissue release contact Pharmacy Development.Queries or comments can be directed to theQueries or comments can be directed to thePharmacy Development Manager via email [email protected]
Recognition Manual 2014 Page 79