REAERATION OF STREAMS AND RESERVOIRS … · of references concerning the application of aeration...
Transcript of REAERATION OF STREAMS AND RESERVOIRS … · of references concerning the application of aeration...
REC-OCE-70-55
D. L. KingEngineering and Research Center
December 1970
U. S. Department of the InteriorBureau of Reclamation
REAERATION OFSTREAMS AND RESERVOIRSANALYSIS AND BIBLIOGRAPHY
BM-230 (6-70) Bureau of Reclamation
1. REPORT NO.
REC-OCE-70-55 4. TITLE AND SUBTITLE
Reaeration of Streams and Reservoirs, Analysis and Bibliography
7. AUTHOR($)
D. L. King
9. PERFORMING ORGANIZATION NAME AND ADDRESS
Division of General Research Engineering and Research Center Bureau of Reclamation
Colorado 8022
Same
15. SUPPLEMENTARY NOTES
16. ABSTRACT
5. REPORT DATE
December 1970 6. ERFORMING ORGANIZATION CODE
PERFORMING ORGANIZATION REPORT NO.
REC-OCE-70-55 10. WORK UNIT NO.
11. CONTRACT OR GRANT NO.
13. TYPE OF REPORT AND PERIOD COVERED
14. SPONSORING AGENCY CODE
Bureau of Reclamation responsibility for maintaining or enhancing the water quality associated with its projects has resulted in a comprehensive program of research in water quality and pollution control. A literature search and state-of-the-art review to determine the need for future research in reaeration of streams and reservoirs revealed a large number of references concerning the application of aeration methods and equipment to waste treatment. Generally, the application of this technology to aeration of large volwnes of \~ater such as rivers and reservoirs remains to be developed, although several applicable references were found. Questions regarding atmospheric reaeration in streruns remain unresolved. Research is also needed regarding the aeration capability of hydraulic structures and control devices, development of new methods and equipment, effects of dissolved air on cavitation, and comparative economics of various methods and equipment. Ecological effects of reaeration are being considered in a separate review.
17. KEY WORDS AND DOCUMENT ANALYSIS
a. DESCR /PTORS-K I *aeration/ *streams/ *reservoirs/ instrumentation/ oxygen sag/ mathematical analysis/ theory/ mass transfer/ equipment/ *dissolved oxygen/ methodology/ industrial waste treatment/ sewage treatment/ water quality/ efficiencies/ economics/ *bibliographies/ *reviews/ cavitation/ biochemical oxygen demarid/ *reaeration/ oxygen requirements
b. tDENTtF tERS-- I cavitation control/ oxygen rxchange/ empirical equations/ fonnulas ~ ·
c. COSATI Field/Group
18. DISTRIBUTION STATEMENT
Available from the National Technical Inforrnati Service, Operations Division, Springfield, Virginia 22151
1. NO. OF PAGE
131 2. PRICE
$3.00
REC-OCE-70-55
REAERATION OF
STREAMS AND RESERVOIRS
ANALYSIS AND BIBLIOGRAPHY
by
D. L. King
December 1970
Hydraulics Branch Division of General Research Engineering and Research Center Denver, Colorado
UNITED STATES DEPARTMENT OF THE INTERIOR * BUREAU OF RECLAMATION Ellis L. Armstrong Commissioner ·
ACKNOWLEDGMENTS
This report was prepared in the Hydraulics Branch under the supervision o.f W. E. Wagner, Chief, Hydraulics Branch.
The assistance of the Technical Evaluation Section, Engineering Reference Branch, in preparing the bibliography was essential. G. W. DePuy provided supervision of this task. The work of Miss Linda Gray in locating and assembling the references is particularly appreciated.
The Applied Sciences Branch, under L. 0. Timblin, cooperated in determining the scope of the study and in providing guidance during the preparation of the report. P. R. Tramutt and D. A. Hoffman were especially helpful in this respect. E. T. Lyons provided assistance in the collection of references.
The excellent work of Mrs. Leanne Morris in typing the manuscript of the bibliography several times is gratefully acknowledged.
The Science Information Exchange provided descriptions of current research activity.
The review and suggestions offered by Dr. Ernest C. Tsivoglou, Georgia Institute of Technology, were extremely helpful.
The information contained in this report regarding commercial products or firms may not be used for advertising or promotional purposes and is not to be construed as an endorsement of any product or firm by the Bureau of Reclamation.
Notation Purpose Conclusions Application Introduction Dissolved Oxygen Requirements Oxidation Reaeration
Basic Theories of Reaeration Empirical Studies
Effect of temperature
Photosynthesis Artificial Reaeration
Cascades Valves . Diffusers Mechanical aerators Turbine injection Hydraulic guns . U-tubes Venturi tubes Pressure injection Miscellaneous methods Hypolimnion reaeration Reaeration by reservoir mixing
Reaeration with Molecular Oxygen
CONTENTS
Overall Comparison of Artificial Reaeration Methods Other Applications of Reaeration Methods
Cavitation control . . . . Velocity and discharge control Removal of suspended matter Fish control . . . . . . Ice control Control of surface pollutants Evaporation control
Instrumentation Research Needs
Reported Research Current Research Activity Suggestions for Future Research
Page
1 2 3 4
4 7
9
10 10
10 11 11 14 15 16 16 17 17 17 17 18
l l8 19 19
19 23 23 23 23 23 23
23 24
24 24 24
CONTENTS-Continued
Glossary of Terms . . . . . . Definitions of Mathematical Terms Bibliography Preface Bibliography Bibliography Index
Tables
1 2 3 4
Figures
1 2
LIST OF TABLES
Efficiencies of Several Reaeration Devices Overall Comparison of Reaeration Methods Annual Costs of Reaeration Costs of Applied Reaeration Systems
LIST OF FIGURES
Oxygen Balance in a Finite Element Dissolved Oxygen Saturation Values
ii
Page
27 29 31 35
129
18 20 21 22
2 5
NOTATION
Dimensions of mathematical terms are given in general terms of mass-length-time (M-L-T). For example, concentrations are expressed in the form of M/L 3. This form cor~esponds to English system units of lb/tt3 or to Metric system units of mg/1 . Similarly, the rate of mass transfer in general terms is expressed as M/L 2_ T, corresponding to lb/ft2-sec in English notation or g/m2-sec in the Metric system.
PURPOSE
The literature survey was conducted for the purpose of preparing a summary of the state-of-the-art for defining research needs in the field of reaeration of streams and reservoirs.
CONCLUSIONS
The literature reflects a large amount of information on the waste treatment applications of reaeration. The use of diffusers and mechanical surface aerators is particularly well documented. Basic theories of mass transfer and bubble dynamics have also been widely investigated with emphasis on waste treatment.
Generally, the application of these theories and methods to large volumes of water such as rivers and reservoirs remains to be developed. Some work has been reported concerning the use of turbine injection, diffusers, and mechanical aerators for stream reaeration, and new devices such as the U-tube are being investigated; however, additional research is needed. The use of control devices, such as the Howeii-Bunger valve, for reaeration, is in an early stage of investigation, and the reaeration capability of energy dissipaters has had very little attentipn.
Reaeration of reservoirs has been primarily concerned with mixing by diffused air or pumping, with
---·accompanying atmospheric .·re(Je~:tiof'l ,J:~t .th~,. water_,, surface.
The effect of dissolved air on cavitation continues to be an area requiring further investigation.
Activity in mathematical simulation and prediction appears to be adequate. However, questions remain
concerning atmospheric reaeration in streams, particularly correlation with hydrauiic parameters.
There is an apparent deficiency in the area of economic analysis and cost comparison of methods and devices for reaeration. The methods of defining efficiency need to be standardized.
These conclusions point to the difficulties facing designers of equipment for reaeration of streams and reservoirs. The research activity in this field has not been collected into a set of criteria for design purposes.
APPLICATION
This report was prepared for the use of the Bureau of Reclamation in planning a program for research in reaeration. The bibliography provides references for use in the design and operation of reaeration equipment and for determining reaeration requirements.
INTRODUCTION
The Bureau of Reclamation has responsibility for maintaining or enhancing the quality of water associated with its projects.
Because of this responsibility, the Bureau is engaged in a comprehensive program of research in water quality and pollution control. This program includes determination of methods and techniques for water-quality monitoring and control, studies of water-quality paramet~rs in large and small impoundments, investigation of eutrophication problems, preimpoundment studies for estimating future reservoir water quality, prediction of reservoir temperatures, laboratory studies for selective withdrawal, determination of basinwide influences on water quality, establishment and review of standards and criteria, studies of irrigation return flow, a':ld s:t!-!die~: of the ... n~lati9,nstJip_s e1rnon.9 st~u.,gtyn~s, •. r~!tQIHiJ .site preparation, and water quality.
Reaeration of streams and reservoirs offers promise in improving water quality. Examples of this application would be reaeration of low-level releases from stratified reservoirs for protection of the stream fishery or in-stream aeration of a polluted river to increase the
·capacity for assimilation of wastes. Techniques for reaeration of small streams and impoundments have been investigated and found to be applicable in varying degree. However, large streams and reservoirs introduce problems which do not allow immediate application of these techniques.
Reaeration has been used for many years in waste treatment, as in the activated sludge process. In-channel aeration for the recovery of badly polluted streams has received increasing att~ntion.
Figure 1 shows the means by which oxygen enters or leaves a segment of a stream or reservoir. An easily defined contribution is through bulk flow; that is, the oxygen contained in the water entering and leaving the segment. Oxygen also enters the segment through precipitation which would also be considered as bulk flow. Other contributions ate from chemicals, chemical reactions, and photosynthesis in plants. The most important natural addition of oxygen occurs through atmospheric aeration. Artificial oxygenation can be accomplished with air diffusers, mechanical aerators, or other devices.
In addition to bulk flow, oxygen leaves the system through decay of organic materials in the flovv or on the bottom, plant respiration, and chemical reaction, such as nitrification (transformation of ammonia nitrogen to nitrates).
The earliest attempt to define the dissolved oxygen regime of a stream was made by Streeter and Phelps (S-37) with' their oxy'gen sag equatio.n:
where
D dissolved oxygen saturation deficit t time L biochemical oxygen demand (BOD)
decay (deoxygenation) rate constant reoxygenation rate constant
( 1)
The dissolved oxygen saturation deficit is defined as:
D = (Cs- C)
2
BULK FLOW ORGANIC LOAD
OXYGEN IN CHEMICALS ATMOSPHE RIG REAERATION
MECHANICAL AERATORS DIFFUSERS OTHER DEVICES
= DISSOLVED OXYGEN CARBONACEOUS BOD BULK FLOW BULK FLOW}
1 t' DRGA.NIC LOAD 1 NITRIFICATION {DISSOLVED OXYGEN
SLUDGE} SLIMES
RESPIRATION ORGANIC LOAD . , CHEMICAL REACTION
SE DIM ENTATION
I . ·· BENTHIC OE/MAND I
Figure 1. Oxygen balance in a finite element after Hann (H-3).
where {;
saturation concentration initial existing concentration
The oxygen-sag equation may be misapplied because:
a. Deoxyg~nation and reoxygenation are not always first order reactions as shown in the equation.
b. The equation is idealized in that other means of oxygen inflow and outflow are not included.
c. Application to long stretches of the stream is not necessarily valid because of changing conditions a.nd local variations.
An oxygen balance in a finite element, using the f~<;:tc;>rJ s_h()"'!rt __ i:n. Fi~!Jre 1:, . _Jl1o_re app~opriately describes the actual physical situation. If the means of oxygen inflow or outflow can be described by differential equations, solution can be obtained by a method of finite differences. It is important to note, however, that Equation ( 1) is accurate under the conditions to which it is restricted.
DISSOLVED OXYGEN REQUIREMENTS
Dissolved oxygen is required for the survival and growth of many aquatic organisms, including fish. Also, the absence of dissolved oxygen leads to
anaerobic decay of organic matter and results in undesirable esthetic qualities.
Federal recommendations for the levels of dissolved oxygen (C-22) for maintenance of fish and other aquatic life are quoted below:
"(1} For a diversified warm-water biota, including game fish, daily DO concentration should be above 5 mg/1, assuming that there are normal seasonal and daily variations above this concentration. Under extreme conditions, however, and with the same stipulation for seasonal and daily fluctuations, the DO may range between 5 mg/1 and 4 mg/1 for short periods of time, provided that the water quality is favorable in all other respects. In stratified eutrophic and dystrophic lakes, the DO requirements may not apply to the hypolimnion. In shallo"'r unstratified lakes, they should apply to the entire'circulating water mass.
"These requirements should apply to all waters except administratively established mixing zones. In lakes, such mixing zones must be restricted so as to limit the effect on the biota. In streams, there must be no blocks to migration and there must be adequate and safe passageways for migrating forms. These zones of passage must be extensive enough so that the majority of plankton and other drifting organisms are protected (see section on zones of passage).
"(2) For the cold water biota, it is desirable that DO concentrations be at or near saturation. This is especially important in spawning areas where n·olevels must not be below 7 mg/1 at any time. For good growth and the general well-being of trout, salmon, and other species of the biota, DO concentrations should not be below 6 mg/1. Under extreme conditions they may range between 6 and 5 mg/1 for short periods provided that the water quality is favorable and normal daily and seasonal fluctuations occur. In large streams that have some stratification or that serve principally as migratory routes, DO levels may be as low as 5 mg/1 for periods up to 6 hours, but should never be below 4 mg/1 at any time or place.
"(3) DO levels in the hypolimnion of oligotrophic small inland lakes and in large lakes should not be
3
lowered below 6 mg/1 at any time due to the addition of oxygen-demanding wastes or other materia Is."
OXIDATION
As discussed earlier, the dissolved oxygen regime of a stream is expressed by the Streeter-Phelps-'oxygen sag equation:
( 1)
In addition to bulk flow, the maj_q-r depletion of oxygen occurs by decay of organic matter (BOD). Carbonaceous, or first-stage BOD is described by:
dl -=-K1L dt .
The solution to this equation is given by:
-K1t L = L e a
(1a)
(1b)
where La = the initial BOD at the start of the decay
process. This decay can occur in the flow or on the bottom. Oxygen demand also occurs by nitrification (C-26, S-32, S-33, W-9). The nitrification stage sometimes occurs after the carbanaceous stage is completed and can be very significant, particularly in reservoirs.' Streeter {S~34, s~35)disc\Jssed th'is· tWO-stage oxidation in detail. It must be emphasized that the oxidation process is complex and variable from one case to another. Determination of oxygen demand in streams and reservoirs should be attempted only with a complete understanding of the processes involved.
Other chemical reactions result in lesser oxygen depletion.
Krenke!, et al (K-26) discuss the effect of reservoirs on the removal of BOD by biological oxidation. Reduced velocity causes oxygen demand to take place closer to the point of waste discharge. Reservoirs can be advantageous by providing large volumes of water for dilution of wastes. If the reservoir is stratified,
however, wastes can be confined to the hypolimnion and result in depletion of DO in that zone. DO depletion in the hypolimnion can also be caused by
decay of sludge or otber organic materials which have settled to the bottom of the reservoir. Settling of dead algae from the surface is a common example of this. If stratification persists for long periods of time, no atmospheric reaeration occurs, and DO can drop to zero in the hypolimnion. Therefore, low-level releases from a reservoir might have a desirable temperature, but be completely unacceptable in terms of DO.
Low DO also causes iron and manganese to return from the solid precipitated form back into solution. This condition can cause taste and odor problems in municipal water supplies.
Krenkel, et al discuss the variation of the decay rate constant with bacteria concentration, waste concentration, turbulent mixing, and temperature.
Variation of the decay rate constant K1 with temperature is usually determined by the relationship:
where
K1 (T) = K1 (20) e(T-20)
rate constant at T° C rate constant at 20° C a constant, usually 1.04 7
(2)
Reference (K-26) includes a discussion of variation of 8.
Velz (V-7) states that BOD effects of bottom deposits may become acute where reservoir inflow velocities are less than 0.6 fps. Sludge deposits were found to return to suspension for velocities above 1.0 to 1.5 fps. The nature of the bottom material and currents within a given reservoir will, or course, determine the -specific considerations for that reservoir.
Krenkel, et al (K-26) explain that reservoirs usually show improvement in water quality as the bottom deposits are oxidized or leached into solution and discharged. This applies particularly to debris which exists at the initial filling of the reservoir. The paper includes a tabulation of the oxygen demand of· various types of soils and litter.
4
REAERATION
Basic Theories of Reaeration
Fick's first law of diffusion is expressed in vector notation as:
where
PA PB p
\/WA =
DAB=
gas liquid mass flux of A, M/L 2T mass flux of B, M/L 2T PAIP mass fraction of A,
dimensionless mass density of A, M/L 3 mass density of B, M/L 3 PA + llB = mass density of solution,
M/L3 mass density gradient, L -1 mass diffusivity of gas into liquid,
L2/T
The first term on the right side of the equation
represents transfer by bulk flow while the second term
represents transfer by molecular diffusion. Therefore,
mass transfer by molecular diffusion (assuming a still
liquid) is represented by:
(4)
Considering the x-direction only, and changing to
scalar notation, an alternate form is:
where
am= -Om ac at ax
rate of mass transfer per unit area, M/L2T
Dm -F molecular diffusivity, L 2T
ac ax concentration gradient, M/L 4
(5)
Equation (5) describes steady-state transfer. If the concentration varies with time as well as distance:
(6)
which is a form of Fick's second law of diffusion. A solution to this equation was found by Stefan (S-28, S-29) in 1878 and later applied by Phelps. The solution is:
where
1 -9Kd 1 -25Kd ge +25 e + .... )
2Dmt 4h2
h depth of water Dm molecular diffusivity Ct concentration at time t Cs saturation concentration C0 initial concentration, t = 0
(7)
The molecular diffusivity of oxygen into water has been estimated ( K-3) to be 2.1 cm2/sec at 20° C.
The dissolved oxygen saturation deficit, D, is determined in aeration problems by the difference between the initial existing concentration, C0 , and the concentration at saturation,· Cs. The saturation concentration depends upon the solubility of air or oxygen in water, which in turn depends upon temperature, pressure, and salinity. For example, with zero salinity, Figure 2, the solubility C5 varie~ from about 14.6 mg/1 at 0° C to about 7.5 mg/1 at 30 C, at atmospheric pressure. Phelps suggests a reduction in solubility of 10 percent for each 10,000 mg/1 salinity (as chlorides). The saturation value increases with pressure.
As shown in Equation ( 1), the rate at which oxygen is absorbed is expressed as being directly proportional to the saturation deficit:
(8)
5
This equation can be integrated to give a solution in the form:
(9)
where 0 0 is the initial deficit.
An alternative form is:
(10)
where
Some references fail to show this distinction in the use of K2 and k2.
.:::. 15 01
£ .. 1~ I
z 13
~ 12 >X I 0
I
0 10 w
~ 9 0 (f) 8 (f)
1'.
0 7 0
i' _.........- v D.O.=- 14.652--0'.410'22 t 1 j··
"< + o. oo7991o tz -o.oooo7774P +---
1"-...
i'-~ ..... ~
' :--....... .............
I ....... r----...
t---... -r--
2 4 6 8 10 12 14 16 18 20 22 24 26 28 30
TEMPERATURE- 0 G
Figure 2. Experimentally determined and computed dissolved oxygen saturation values from Reference C-20
Evaluation of K2 is the key to the development of an accurate description for the reaeration '!'echanism. Several theories have been proposed to provide an analytical basis for determination of K2. Whitman (W-14), and Lewis and Whitman (L-11), in 1923 and 1924, presented the two-film theory. This theory makes four major statements:
1. Laminar layers of gas and liquid at the interface control the transfer process.
2. The laminar liquid film at the water surface controls the rate of oxygen transfer through the surface.
3. The film is saturated with oxygen at the surface.
4. The water is well mixed so that the concentration is uniform in the body below the laminar film.
Thus, a steep concentration gradient exists in the film and oxygen transfer takes place by molecular diffusion according to Fick's Law (Equation (5)), which becomes:
where
-ADmD q = --b:---
q rate of oxygen transfer, M/T A surface area, L 2
( 11)
Dm molecular diffusion coefficient, L 2fT D saturation deficit, M/L 3 b stagnant film thickness, L
A liquid film coefficient, KL, is introduced as a correlary to a rate constant, giving:
where
Dm b
( 12)
The film theory has not been generally accepted because the assumption of a laminar film is not
.. physically realistic. It must .also be. notedcth~t the film thickness b has never been measured; therefore, analytical evaluation of KL is not possible.
The term KLa also appears in the literature. Dividing both sides of Equation ( 12) by the volume V expresses the rate of change in concentration:
where
Objections to the film theory resulted in several alternatives being offered. Higbie ( H-1 0) proposed his film penetration theory, which assumes that the transfer process takes place through alternate cycles of gas absorption and mixing. The water body is assumed
6
to be stagnant for a short period during which oxygen is absorbed and downward molecular diffusion occurs. Then, the water is completely mixed and the cycle begins again. This theory led to an alternate expression for KL:
( 14)
where t' is the time required to complete one cycle of absorption and mixing. The penetration theory was the first to recognize the importance of turbulent mixing in renewing the unsaturated water exposed to the free surface. From a physical view, however, the assumption of alternate periods of stagnation and mixing is obviously unrealistic. Also, the penetration theory still contains the objectionable assumption of a surface film.
Danckwerts (D-2) extended the penetration theory by stressing the idea of surface renewal. He questioned the film concept and suggested a statistical distribution for mixing of individual elements. This approach seems more realistic, in view of the physical structure of turbulence.
The statistical distribution is expressed as:
f(t) = re-rt (15)
where r is a rate of surface renewal, expressed as a fraction. Therefore, r is analagous to the reciprocal of t' in Equation ( 14). Danckwerts proposal thus results in:
( 16)
Dobbins (D-11) combined the film theory with the surface renewal theory by assuming continuous mixing below the film along with continuous renewal of the surface film and molecular diffusion within the film. Using Danckwerts' statistical distribution and a film thickness b, Dobbins derived:
( 17)
Also, as r approaches a large number, KL approaches that defined by the surface renewal theory; i.e.,
KL ~v'Dmr.
O'Connor and Dobbins (0-2) determined that Equation (17) would be identical to Equation (16) forvaluesof r, b, and Dm which typify natural streams. They further postulated that streams had either non isotropic turbulence or isotropic turbulence, depending on whether Chezy's "(; was· less than o·r greater''than 17', respectively. Many investigators have recognized that this appears to be a rather arbitrary way of defining isotropic turbulence. Actually, O'Connor and Dobbins, by their definition, found that most streams which they analyzed had isotropic turbulence. To test their concept of surface renewal, they performed laboratory experiments using an oscillating grid to produce turbulence. The results indicated a good correlation between the grid oscillation frequency and the observed k2.
This theoretical and experimental work led to the expression:
( 18)
for isotropic turbulence and
480 Om 1 /2s 1/4 k2 = H5/4 e ( 19)
for nonisotropic turbulence.
In these equations:
IT average flow velocity H average flow depth Se energy gradient
As mentioned above, most streams were found to conform to Equation ( 18). The measurements were made on reaches selected to minimize effects of bottom sludge deposits and algae. As much as 50 percent variation between' theoretical values of k2 and those determined by the field measurements was noted.
Empirical Studies
The foundation for empirical evaluation of k2 was the work of Streeter and Phelps (S-37) on the Ohio River.
7
Their oxygen sag equation was referred to earlier as Equation ( 1). By applying this equation, they indirectly measured values of k2. Streeter and Phelps correctly hypothesized that the k2 values should be related to temperature, depth, and turbulence in the stream. Assuming the temperature to be constant, they reasoned, with the aid of the solution to Fick's second law (Equation (7)), that k2 should be approximately proportional to the inverse square of the depth. Also, they felt that the remaining factor, turbulence, should be direCtly proportional to cF·power functi:on of, the· flow velocity. They thus derived the empirical relationship:
cvn k2 = H2 (20)
where C and n are constants that must be determined. The Ohio River measurements of Streeter and Phelps resulted in n values ranging from 0.57 to 5.40 and corresponding C values from 0.23 to 131. The need for caution in general application of Equation (20) is obvious.
Churchill, et al (C-12) used a strictly empirical approach to develop the relationship:
where
k2(20) = 5.026u0.969 H-1.673 (21)
reaeration coefficient at 20° C average velocity, fps mean depth of flow, ft
Multiple regression analysis was used with 509 sets of data to develop Equation (21), which is applicable to unpolluted streams.
This data collection program was accomplished with great care. The studies were conducted in streams below impoundments for which releases were low in dissolved oxygen and BOD. The reaches were chosen to have relative uniform hydraulic parameters of slope, depth, and shape. Generally, Churchill, et al attempted to eliminate those factors which tend to mask the true value of k2. These data are generally accepted to be the most reliable available at the present time.
Owens, et al (0-9) combined the data of Churchill, et al (C-12) and Gameson, et al (G-2), and by regression analysis developed the equation:
k2(20) = 9.41 ij0.67 H-.-:1.85 (22)
for velocities of 0.1 to 5.0 fps and depths of 0.4 to 11 ft. Using their own data for fast-flowing, shallow streams, they obtained the equation:
k2(20) = 10.1 ij0.73 H-1.75 (23)
which gives a k2 considerable higher than determined by data of Chu rchi II, et al, Equation (21).
The experimental procedure and interference by bottom oxygen demand and plant photosynthesis make the results rather speculative, even though correction factors were applied. The restriction to fast-flowing, shallow streams is also an important limitation, even if the relationship could be accepted as valid.
Isaacs and Gaudy (1-11) used a rectangular laboratory flume to develop the expression:
(24)
The similarity of these empirical relationships with that originally proposed by Streeter and Phelps should be noted.
Much time and effort has been devoted to attempts to relate the reaeration coefficient k2 to the hydraulic parameters of velocity and depth. Little progress has been made, for the following reasons:
1. Average values of velocity and depth are poor measures of flow conditions in a stream. Churchill, et al, for example, cautioned against applying their results to reaches with white water.
2. Even if these average parameters were acceptable correlations, they would be extremely difficult to measure accurately in the field.
3. Other effects, such as BOD, cannot be isolated when analyzing relatively long reaches.
Intuitively, the reaeration rate should be related to some measure of turbulence, as indicated in several of the investigations described above. Since turbulence is difficult to measure directly in the field, some investigators have attempted to relate k2 to some indirect indicator of turbulence, such as eddy size or the rate of energy dissipation.
Krenke! and Orlob (K-23) applied kinetic gas theory to explain the transfer process. The change of reaction rate with temperature is given by:
8
where
k Ea
Ea
k = A'e RT
the reaction rate energy required by a molecule to be
included in a reaction R the universal gas constant T absolute temperature A collision factor (analogous to a
frequency)
(25)
Krenkel and Orlob reasoned that the movement of molecules from one equilibrium position to another in turbulent shear flow is analogous to the movement of molecules over a barrier of potential energy, for which a certain activation energy is required. Furthermore,
-they-argued that -someintemal flow .mechanism .such as turbulence was required to sustain the absorption process. The longitudinal mixing coefficient was chosen as being the most appropriate. This coefficient was evaluated in the laboratory experiments by measuring the dispersion of an injected tracer. Correlation of this parameter with oxygen absorption measured in the laboratory flume gave:
Ea
k = 1.418e- RT ~- 0.0069 (26)
where
DL longitudinal mixing coefficient h depth of flow
DL/h2 is proportional to the frequency at which gas molecules collide with the surface layers, and can be considered as a surface renewal rate.
Harleman and Holley (H-4) questioned the use of the longitudinal mixing .coefficient as a measure of turbulence, explaining that the mechanism is one of dispersion caused by convective effects and is not, therefore, representative of turbulence. They suggested that the correlation was actually between k2 and the average vertical eddy diffusivity.
Krenkel and Orlob also found a direct relationship between k2 and the rate of energy dissipation in their laboratory flume. This relationship is:
where
h
k2 = (1.141 X 10-4) E0.408 h-0.660
k2 corrected to 20° C rate of energy dissipation per unit
mass flow depth
In open channel flow:
E =uSe g
where
u mean flow velocity Se energy gradient g gravity
(27)
(28)
The correlation between k2 and E appears to be a very valuable result of the work, even though it was not given primary emphasis in the paper. However, in defining E, the difficulty remains in measurement of u.
Krenkel and Orlob also suggest that the absorption rate of some gas should be in known proportion to that of another gas. In cases where the absorption rate. of oxygen might be affected by BOD, for example, some other gas could be used to indirectly measure the oxygen absorption rate. The possible use of radioactive gases was mentioned.
Tsivoglou (T-28) describes such a method for direct measurement of the reaeration capacity of a stream. The method uses radioactive gas tracers to determine both dispersion and gas transfer. This represents the first known attempt to measure k2 directly. All previous work has involved an indirect evaluation of k2 through computation based on an oxygen-sag curve, even though the value thus obtained has been referred to as being "observed." The tracer method was developed in the laboratory and demonstrated in full-scale field studies.
Tsivoglou stresses that the tracer method should be considered as a primary standard, to which all the empirical results described earlier should be compared.
The O'Connor-Dobbins equation and the equation of Churchill, et al, were found to give approximate predictions for the Jackson River in Virginia. Tsivoglou states that comparisons of this type must be made with caution, because of errors in determining hydraulic parameters of the stream. More cross sections are
9
necessary for accurate computations than are usually practical from a cost standpoint.
Effect of temperature.-The most commonly used description of the effect of temperature on k2 was given by Streeter and Phelps ( S-37):
where
reaeration coefficient at~ C reaeration coefficient at 20° C
(29)
Krenkel, et al (K-26) summarize the work of other investigators. They state that O'Connor and Dobbins (0-2) and Krenkel and Orlob (K-23) predict a coefficient of 1.016. However, this value is incorrect and has apparently been confused with the correction coefficient for surface transfer as reported by Streeter, Wright, and Kehr (S-35).
Dobbins (D-11) maintains that the coefficient should be variable. Tsivoglou (T-28) found the relationship:
(30)
where() was 1.022 ± 0.003. Churchill, et at (C-12) found that (} = 1.024, based on a large number of measurements.
A relationship in the form of Equation (20) should generally apply to evaluation of k2 for open structures and jets. However, where high velocities or severe surface turbulence occur, atmospheric reaeration is higher than that predicted by any of the empirical equations. Very little work has been done in this area. Tsivoglou's tracer method might be appropriate in this case.
This review of the state-of-the-art, with respect to natural reaeration of streams, indicates that attempts are being continued to better define correlation with hydraulic parameters. Empirically derived equations, most in the basic form of Streeter and Phelps' original work, continue to be used for lack of something better. Tsivoglou's tracer method for direct measurement of k2 is a promising development, but remains restricted
to in situ measurements. It is not yet suitable for prediction, because of the usual barriers in relating k2 to hydraulic parameters.
It seems to the writer that correlation with some measure of energy dissipation is the only rational approach. Energy dissipated is the only means of summarizing activity within a finite segment of the stream. However, it is not difficult to imagine possible differences in stream segments with similar energy dissipation (such as a tranquil stream segment with a waterfall versus a segment with rapids).
Photosynthesis
Photosynthesis is the process by which carbohydrates are formed from water and carbon dioxide by chlorophyll in living plants. The reaction results in the release of oxygen.
Krenke!, et al ( K-26) discuss the importance of photosynthesis as an oxygen source in reservoirs and summarize the thinking of several investigators. Experience has shown that the relative contribution of photosynthesis has ranged from unimportant to very important. Photosynthetic oxygen should be considered in the oxygen balance but should not be depended upon for waste assimilation. Knowledge in this subject has not advanced sufficiently to allow satisfactory application in practice. Hull (H-18, H-19, H-20) has published several papers on this subject. Other references include Edwards (E-5), lgnjatovic {1-2), Mackenthun (M-1), Verduin (V-8), and Winberg and Sivko (W-21).
Artificial Reaeration
Thackston and Speece (T-15) report that when mechanical devices are used for stream aeration, a level of 40 percent of saturation prior to reaeration is often considered as the upper limit for economical aeration. Aeration facilities should generally be located at the low point on the oxygen sag curve. Site choice is also influenced by the location of existing facilities (such as those with head loss), power availability, accessibility, and availability of personnel for operation and maintenance (T-15).
The break-even point of oxygen deficit versus cost of artificial reaeration depends on the characteristics of the particular device. The statement of 40-percent saturation may apply to many devices. However, a more appropriate general statement might be simply that efficiency of reaeration devices is directly proportional to the oxygen deficit, just as in natural reaeration.
10
Cascades. -Several British researchers (8-5) have investigated atmospheric reaeration at weirs. Data -from four weir systems resulted in the empirical equation:
where
a
b
T h
r = 1 + 0.11 ab ( 1 + 0.046 T) h (31)
ratio of upstream saturation deficit to downstream saturation deficit
coefficient for water quality (1.25 · for slightly polluted water, 1.0 for moderate pollution, and 0.8 for sewage effluent)
1 for a free weir, 1.3 for the examined step weirs
water temperature, ° C height of free fall, ft
The equation was partially verified for flows of 1 to 500 million gallons per day (mgd) (1.55 to 774 cfs). The equation also applies to loss of oxygen' from supersaturated water. The authors state that most of the oxygen uptake resulted from splashing at the base of a free fall. Therefore, efficiency would be expected to increase with the number of steps, as indicated by the value of b. This is conjecture, although not entirely without basis. The phenomenon is likely a combination of insufflation, splashing, and turbulence (conjecture by the writer).
In an earlier reference, Gameson (G-6) presents a somewhat simpler relationship:
r = 1 + abh/2 (32)
where the parameters are as defined above, except that h is measured in meters~ The effect of water temperature is not considered.
Very recently, Huckabay and Keller (H-16) have described a "cascade board." The development of this device was partially stimulated by Gameson's finding that the efficiency of aeration at weirs was -directly related to the number of steps. The experimental apparatus consisted of a variable slope board covered with corrugated metal, with the corrugations transverse to the direction of flow. Tap water was used for the tests. Flow rate varied from 0.02 to 0.08 mgd/ft of width (about 0.03 to 0.12 cfs/ft).
The mass transfer coefficient K La was expressed in terms of a "penetration factor," which in turn was related to a modified Reynolds number and the Schmidt number. The modified Reynolds :number included flow rate, board length and inclination, and
kinematic viscosity. The Schmidt number consisted of kinematic viscosity, density, and molecular diffusivity.
The authors conclude that the "cascade board" appears to be a promising aeration device. However, it is very difficult to extract information concerning actual mass transfer rates or coefficients from the paper. They state that additional investigations are being planned.
The writer suggests that these preliminary results should not be directly applied to aeration of large discharges, particularly in view of the very small discharges tested.
Aeration at weirs is also discussed by Albrecht (A-3, A-4), Grindrod (G-17), Manzack (M-5), Scott and Wisniewski (S-5), and Thackston and Speece (T-15).
Weirs as aeration devices have the advantages of being relatively maintenance free and requiring no direct energy expenditure. Where "free" head is available, weirs can be used very beneficially. However, if the head determines power loss or pumping requirements, cost of operation must be determined on that basis. Possible disadvantages of weir aeration systems are high capital cost, particularly for large structures, and low transfer efficiency.
Valves.-The Tennessee Valley Authority (TVA) (E-7) has evaluated the fixed-cone (Howeii-Bunger) valve for aerating reservoir discharges. Tests were conducted with discharge either to a partially enclosed jet containment structure or to a tailwater pool. Aeration efficiency was found to be related to the discharge velocity. Jet thickness had little effect in the range covered by the tests. At discharge velocities less than 30 fps the discharge to the tailwater pool was more efficient than the confined discharge. For velocities above 30 fps either condition resulted in an oxygen increase greater than 80 percent of the initial deficit. The data show that the initial deficit had a noticeable, but ill-defined effect on the efficiency.
To the writer's knowledge, other control devices such as hollow-jet valves or slide gates have not been similarly evaluated for use in reaeration, even though they would probably have low~r efficiency than the fixed-cone valve because of jet configurations which would result in less air-water contact. However, the reaeration effect might finally be determined by the design of the containment structure, when such a structure is used, or other appurtenances. The TVA work did not separate oxygen uptake by the jet from that in the catchment structure or tail water pool. This would be useful information, if sampling methods could be devised.
11
The amount of DO increase in free chutes and tunnels and in energy dissipaters such as stilling basins, baffled drops, and flip buckets also needs to be determined. Possible reaeration benefits of hydraulic devices and structures which are normally a part of the project plan should not be overlooked. In some cases departures from usual design practice may be required to increase the reaeration benefit.
Diffusers.-Using the penetration theory, gas absorption from rising bubbles can be expressed by (8-19):
where
dm dt Om texp
dm = .... ]4i5rnc dt l1T"teXP' s
(33)
average rate of mass transfer, M/L 2T
molecular diffusivity, L2/T exposure time of bubble (time required
for liquid to pass one bubble diameter), T
solubility of the gas in the liquid, M/L3
This theory assumes the liquid at the bubble surface to be at zero concentration of dissolved oxygen, and that no surface active agents are present.
This equation can also be expressed as:
(34)
where
Vt terminal velocity of the bubble, L/T D' bubble diameter, L
Thus:
(35)
The bubble terminal velo:: i(s g~: ::): v2=4/3- -.-
t f •t (36)
where
g f
'Y 'Ya
gravity, L/T2 friction factor (drag coefficient),
dimensionless specific weight of water, M/L 3 specific weight of air, M/L 3
(1- 'Ya)
However, 'Y :::::: 1 .
Therefore,
overall transfer coefficient or !iquid film coefficient:
KL = Dm [2 + 0.664 ( Re) 1/2 (Sc) 1 /3] '(39) D'
(after B-19)
where
Dm 0' Re Sc
molecular diffusivity, L 2/T bubble diameter, L Reynolds number v/Dm, Schmidt number
2 gD' vt = 4/3 -f- (37) This relationship is more complex than Equation,,(35),
which does not account for viscous effects.
can be used. Johnson, et al (J-8) measured absorption rates of carbon dioxide, ethylene, and butene from sing!e'rising
The friction factor is dependent upon the Reynolds bubbles in a water column to determine the number: relationship:
vtD' Re=--
v
where v =kinematic viscosity, L2/T.
A diagram of f versus Re for spheres is used for a trial-and-error solution.
For example, assume a 1 /4-inch bubble and f = 0.44 as a first trial.
From Equation (37):
2 4/3(32.2)(1/48) v = .. . t 0.44
vt = 1.43 fps
From Equation (38):
1.43(1 /48) Re = (1.664 x 10-5)= 1,700
From the f-Re diagram, f ~ 0.44.
Therefore, the first trial is correct and vt = 1.43 fps.
From boundary layer theory, the transfer efficiency of a bubble diffuser can be expressed in terms of the
12
where
Sh = 1.13 Pe 1 /2 (
de ) 1/2 0.45 + 0.2 de
Sh
Pe
KL de Sherwood number,~
equivalent bubble diameter, L molecular diffusivity, L 2rr
v d~ Peclet number, Om
.{40)
v stream velocity or bubble velocity, L/T
which conformed quite closely to a theoretically derived equation.
An alternate form is:
KL = 1.13 (o.4~7 ~-2 de) 1/2 (41)
These equations apply for Reynold's numbers oetween 500 and 20,000. The bubbles were oblate spheroids, ellipsoids, or spherical caps, depending on the equivalent diameter, which ranged from 0.4 to 2.0 em. Equation (41) applies to equivalent diameters of 0.6 to. 4.0 em. This result can be compared with the
theeretical KL for spherical bubbles from Equation (3~):
_ (4 Om v) 112 KL- rr d
e (42)
with appropriate changes in notation, and with Eq~ation (39). The writer suggests that Equation (41) be:,used. The limitation to spherical bubbles in the ot~er cases is not practical.
The ratio of oxygen transferred from a bubble to the vol;ume of oxygen contained in the bubble determines th~ transfer efficiency.
Similarly, the efficiency of a diffuser system is determined by the ratio of oxygen transferred to oxygen supplied:
where
E TR SR
TR E =-x 100
SR
efficiency, percent oxygen transfer rate, M/T oxygen supply rate, MIT
(43)
Eckenfelder (E-1) summarizes the work of several other investigators and presents the relationship:
Om Re Sc1/2 K = C
L ""(Y" Hl /3
where C is an empirical constant,
H is the tank depth.
(44)
This equation is similar to those presented previously, with the exception of the inclusion of tank depth. It alsb must be noted that Equation (44) holds only for the narrow range of Reynolds numbers of 50 to 500.
Eckenfelder also formulates an overall mass transfer co~fficient for evaluating performance of a commercial diffuser:
(45)
where
v (1-n)
H
liquid film coefficient, min-1 ratio of total bubble surface area to
liquid volume, A/V, ft-1 a constant airflow, SCFM (at standard temperature
and pressure) tank volume, ft3 variable exponent which is a function
of bubble size tank depth, ft
The exponent of H has actually been found to vary from 0.45 to 0. 77 depending on the type of diffuser and the particular application. The exponent ( 1-n) might vary from 0.8 to 1.4, with higher values for smaller bubbles and correspondingly greater transfer rates.
13
Eckenfelder also summarizes the velocity and shape characteristics of air bubbles in water as they vary with the Reynolds number of the bubble. At Re < 300, the bubbles are rigid spheres which rise either in a rectilinear or a helical motion. For Re = 300- 4,000, the bubbles are ellipsoidal in shape and rise with a rectilinear, rocking motion. The bubbles are shaped as spherical caps for Re > 4,000.
Tyler (T-34) produced one of the early proposals for the use of diffusers for supplemental reaeration of streams. He reported an average efficiency of about 7 percent, using carborundum plates and porous tubes under 12 feet of water.
Experience with diffusers in waste treatment is well documented. Reference (T-3) contains an excellent summary of diffuser types, design, and economics as applied to waste treatment.
Diffusers are classified (T-3) as porous or nonporous. Porous diffusers consist of plates or tubes, usually formed with a ceramic of silicon dioxide or aluminum oxide held in a porous mass with a ceramic binder. Porous diffusers may also consist of nonceramic plastic-wrapped tubes or plastic-cloth tubes.
Nonporous diffusers exist in several types. The nozzle and orifice types are made of metal or plastic with larger openings (and larger bubbles) than the porous diffusers. The valve type has a disk or valve which closes when the air supply is cut off. The valve type produces large bubbles. The shear type has a square
shape and an open top through which water enters, thus ''shearing" the bubbles into smaller sizes. The water jet type consists of a system of nozzles which entrain air supplied to one side of the nozzle. For temporary use or in unusual circumstances, perforated or slotted pipes are used. This type is usually used only in shallow water, has a low efficiency, and tends to clog and corrode readily.
Plain jets (Sparjers) are often referred to in the literature. Reference (T -3) describes the Sparjer as a controlled air-release device which utilizes a cluster of four high-velocity short-tube orifices to disperse the air in a controlled pattern. The bubbles break into smaller bubbles a short distance above the device. Orifice sizes vary from 1/8 to 5/16 inch, depending on the application.
Diffuser efficiencies as high as 17.5 percent have been measured in aeration tanks. However, this efficiency seems unusually high, in light of many other references which indicate efficiencies ranging from 2 to 8 percent. Oxygen transfer was found to increase with depth. This is due to the increase in the saturation concentration caused by an increase in pressure. The oxygen saturation deficit is larger, and oxygen transfer occurs at a faster rate.
Fischerstrom (F-5) suggests the use of diffusers close to the surface with introduction of relatively large quantities of air. Several examples of the application of this method in Sweden are described. The method is based on the idea that although transfer efficiency is reduced by introducing air at shallow depths, more air can be supplied for the same amount of power required for deeper diffusers.
The number of diffusers required for a given application depends upon the recommended flow rate per diffuser, which usually varies between 4 and 15 cfm/diffuser (0.1 to 0.4 cu m/min). Diffuser spacing should be 6 to 24 inches. Clogging of diffusers can be eliminated by adequate filtering of the air supply.
Installation of a diffused air system requires blowers and housing, air piping· and headers, diffusers and supports. Annual operating expense consists of power cost and equipment maintenance. Clogging is the most serious maintenance problem (T-4). Reference (T-4) includes aids for economic analysis.
Palladino (P-1) used drilled pipe diffusers under 4 to 5 feet of water and attained an efficiency of only 1. 7 percent.
14
Wisniewski (W-23) reports the use of a bed of diffuser plates on the Flambeau River in Wisconsin, with efficiencies of 6 to 8 percent.
As mentioned earlier, the efficiency depends on the initial level of DO below the saturation level.
Diffusers have been widely accepted as aeration devices and may have application to specific problems of reaeration of streams and reservoirs. However, the writer feels that because of the usual low efficiencies, high initial cost, and possible maintenance problems, alternate devices should be considered. It is the writer's opinion that diffusers probably have an advantage when used in reservoirs, both for direct aeration and mixing. However, their use in streams might be questionable.
Mechanical aerators. -Mechanical aerators accomplish reaeration at the water surface and also often meet mixing requirements in waste treatment practice. Reference (T-3) contains an excellent description of mechanical aerators, including photographs.
Mechanical aerators can transfer oxygen by surface renewal and interchange (surface aerators) or by dispersing compressed air fed below the surface to a rotating agitator or turbine (turbine aerators).
The updraft-type surface aerator lifts large volumes of liquid above the surface for exposure to the atmosphere. The plate-updraft type produces a high level of surface turbulence. The turbine-updraft type (or combination type) consists of a turbine with a pipe or sparge ring discharging air below the rotating blades.
In the downdraft type, air is supplied by the negative head produced by the rotor. External blowers or compressors are not required.
The brush-type surface aerator consists of a horizontal revolving shaft with combs, blades, etc., extending below the water surface.
The efficiency of a mechanical aerator is expressed as:
where
efficiency, lb (or g)/hp-hr overall transfer coefficient, T-1
(46)
D oxygen deficit, M/L 3, W capacity of system, L 3 P brake horsepower, hp
The numerator of Equation (46) can be measured in the field as a single quantity, the weight of oxygen transferred per unit time.
Burns, et al (B-33) describe the use of a pla~e-updraft-type surface aerator placed at the location of minimum DO in a stream. With an initial DO deficit of 100 percent, an efficiency of 2.15 lb/hp-hr (1.61 lb/kwhr) was obtained. A discussion of the paper describes German use of floating aerators for which an efficiency of 1.75 lb/kwhr (2.34 lb/hp-hr) was obtained at 50 percent DO deficit.
Downing, et al (D-15) describe tests of two types of mechanical aerators of British manufacture (Searle aerator and Simplex cone). Effects of temperature, immersion depth, and surface-active agents were determined. Maximum efficiencies for the two types were about 1,450 g/kwhr, or approximately 3.2 lb/kwhr, based on total power consumption. The tests were conducted in full-scale laboratory apparatus with 100 percent DO deficit. The paper also discusses the Kessener brush aerator and the Sheffield system of rotating paddles; however, no efficiency dati are given.
Thackston and Speece (T-15) discuss a floating aerator witn two 10-foot-diameter rotating turbines in vertical draft tubes. Low-lift, high-capacity pumps throw the water into the air from the periphery of the turbines (updraft type). The aerators were used in a canal and efficiencies were 1.3 lb/hp-hr (1.0 lb/kwhr) for flows less than 3,000 cfs and 3.4 lb/hp-hr (2.5 lb/kwhr) for flows greater than 4,400 cfs. Initial DO level was not stated.
In the writer's opinion, mechanical aerators have definite application to stream reaeration, except where they might present hazards to recreation or navigation. In some locations, noise of operation might also be objectionable. Initial cost of the equipment is high. However, a wide variety of types is available. Application to reservoir reaeration is doubtful. The epilimnion is usually well mixed and relatively high in dissolved oxygen. The mixing effect of the mechanical aerators would not, in most cases, extend into the deeper layers of the reservoir.
Turbine injection. -Where power turbines are set above tailwater level, which is usually the case, the vacuum produced in the draft tube can be used to draw air from the atmosphere. Vents can be designed to open
automatically, can be permanently open, or can be valved for closer control. Another method is to introduce compressed air either above or below the turbine runner. This approach is necessary whenever a natural draft due to vacuum does not exist. Many hydroplants include provisions for injection of air for the purposes of cavitation suppression or control of draft tube surging (D-21 ). Therefore, the mechanics of venting, etc., are well known. However, in most cases the increase in DO downstream has been an incidental and unmeasured benefit.
Wagner (W-1, W-2, W-3, W-4) describes early studies in turbine aeration and gives the first detailed discussion of operation, including cost and efficiency.
The most extensive and well documented experience in turbine aeration is in Wisconsin (S-5, S-6, W-16, W-17, W-19, W-23). However, this experience is limited to installations with heads of 8 to 21 feet.
Scott, et al (S-6) describe the results of turbine venting at Pixley Dam on the Flambeau River in Wisconsin. The turbines are the double-runner horizontal type. Air was injected in the annular space between the runner ring and the cone-shaped part of the draft chest which surrounds the runner ring. According to the authors, air injection resulted in a power loss because of reduction in discharge through the turbine. Reaeration efficiencies are stated in terms of this power loss. The maximum DO gain at Pixley Dam was 4.87 lb/kwhr. 37.3 percent of the supplied oxygen was absorbed.
15
Power loss is usually determined by reading power gages in the powerhouse. Scott and Wisniewski (S-5) discuss the determination of true power loss. They state that, although the power output is reduced, water is also saved for later generation because of reduced discharge, thus partially offsetting the cost of the immediate power loss. This statement should not be accepted without reservation. It seems incorrect to attempt to justify a reduction in efficiency in this way.
Wisniewski (W-23) reviews the status of stream aeration on three Wisconsin rivers as of 1965. The paper gives an evaluation of capital and operating costs for turbine aeration and suggests that a power loss of about 5 percent should be expected for low-head dams (15 to 25 feet), with less power loss expected for high dams (over 100 feet). As of 1961, 18 dams included turbine aeration. The range of efficiencies was 1.82 to 5.43 lb/kwhr in terms of power loss.
Palladino (P-1) evaluates turbine venting for reaeration of the Kalamazoo River in Michigan. The venting
added 2 lb/kwhr, with initial DO less than 1 mg/1. Actual addition of oxygen was 0.5 mg/1. Noise in the vent indicated undersizing.
Lee (L-9), in a discussion of Wisniewski's paper, describes aeration experiments with Francis turbines at the Wylie Station plant on the Catawba River in South Carolina. He stresses the importance of turbine characteristics, load, wheel setting elevation with respect to tailwater elevation, vacuum breaker arrangement, and draft tube dimensions and shape with regard to the reaeration effectiveness. Bureau of Reclamation experience with draft tube air injection for control of cavitation and surging in high-head installations has shown an increased efficiency. The slight reduction in discharge is more than offset by the effects of smoother operation. Under these circumstances, draft tube aeration could be considered to be a cost-free benefit.
The possibility of using the draft tubes of dormant turbines for reaeration has been considered, with specific reference to equipment which is no longer used because of age. A logical extension to this idea would be the use of turbines for reaeration during offpeak periods. Reaeration benefits would have to be balanced against cost of water loss.
Since most Bureau of Reclamation projects include hydraulic turbines, the writer feels that this method of reaeration should be carefully considered. However, considerable research will be required. The literature, including the references discussed above, does not provide a clear understanding of the advantages and disadvantages of turbine injection, particularly for high-head installations. Also, experience in turbine venting has not been widely published in comparison with diffusers and mechanical aerators. This is probably because of the wide application of the latter methods to waste treatment.
Hydraulic guns.-The "Aero-hydraulic gun" is described by Bryan (B-27). The device consists primarily of a vertical pipe, 6 inches to 3-1/2 feet in diameter, into which large bubbles are introduced intermittently and automatically. The bubble completely fills the pipe and discharges water from the top of the pipe as new water is drawn through ports near the bottom of the pipe. The device was first used in ice-prevention and local wave control and in aerobic sewage treatment. Aeration occurs through generation of high-velocity surface currents, transfer from the bubbles, and generation of a surface boil. The design is optimized according to the nature of the requirement. Efficiency with an initial zero DO at 20° C is
16
approximately 1.6 lb/brake hp at an aeration capacity of 1 lb/hr (1.2 lb/kwhr), depending upon the details of the design and the primary purpose of the installation. The primary effect of the device is in mixing the water body in which it is placed. It is a relatively low-efficiency aerator and thus has questionable value as an instream device.
U-tubes.-The development of the U-tube device in the Netherlands was reported by Bruijn and Tuinzaad (B-28) in 1958. Further work has been carried out recently by Speece and reported by Speece and others (S-21, S-23, S-24, S-25, S-26). As the name implies, the device is shaped like a U-tube, in which the water flows downward from the entering channel then upward into the exit channel. The two legs can be formed by placing a vertical baffle in a trench.
The main advantages of the U-tube device are:
1. A high rate of bubble surface renewal resulting from turbulence caused by the buoyant force of the bubble.
2. Longer bubble contact time in the downward leg because of downward flow counteracting the buoyancy of the bubbles.
3. Bubble pressurization with increased saturation concentration, resulting from hydrostatic head.
Air is introduced at the top of the downward leg by a natural drop such as a weir, by a constriction in the flow passage, or by injection from a diffuser. Where head loss can be tolerated, natural entrainment is, of course, preferable.
Speece, et al (S-25) describe small-scale experimental studies. Effects of air-water ratio, velocity, depth, injection depth, bubble size, and internal flow constrictions were evaluated. The pilot system was made of 4-inch-diameter pipe. The study showed that water with initial DO of zero could be completely saturated with one pass through a 40-foot-deep U-tube with air injection of 20 percent of the water volume. The paper states that the transfer economy and capital cost of the U-tube are competitive with conventional aeration systems, which are economical only when reaerating waters with low initial DO. The design of U-tube aeration systems has been discussed in a recent paper by Speece and Orosco (S-26). A design example is given, which includes a cost analysis. The U-tube is considered by the authors to be the best device available for saturating a flow with oxygen, but not necessarily advantageous over mechanical surface aerators when producing 40 to 50 percent saturation.
The writer feels that this device shows promise for application to Bureau of Reclamation problems. However, the U-tube has not yet been used for aeration of large open-channel flows. Therefore, application of the results of the small-scale studies reported in the literature may or may not be appropriate. Consideration should also be given to possible plugging of the device with coarse sediment, weeds, or ice.
Venturi tubes. -Bayley and Wyatt (B-8) describe an experimental study in which air was injected at the 3/4-inch-diameter throat of a Venturi section in a 1-1 /2-inch-diameter pipe. Oxygen absorption was measured at various airflow rates, for several water discharge rates. DO was zero at the start of each test. Air was admitted naturally as the result of the vacuum at the throat.
The increase in DO varied directly with the ratio of air to water in the system. The presence of air in the Venturi caused an increase in head loss, as compared to the loss with no air present. The loss also increased with increased velocity. The study did not separate these effects.
The maximum transfer efficiency obtained was 850 g/kwhr of energy loss (1.9 lb/kwhr). The maximum efficiency occurred only when the DO absorbed was less than 0.5 ppm. For higher absorptions (and higher velocities) efficiency was reduced because of increased head loss. The paper states that some reduction in efficiency resulted from small bubbles coalescing into large bubbles in the main pipe, thus reducing the bubble surface area.
Additional experiments were performed in which the flow was discharged directly into a tank. The bubbles were thus allowed to rise from the exit of the pipe to the water surface. A maximum efficiency of 1,150 g/kwhr (2.5 lb/kwhr) was obtained with this method.
Addition of detergents resulted in a substantial increase in efficiency, which is in contrast to observations made on diffused air systems. The authors speculate that this is due to an increase in the interfacial area of the rising bubbles, but do not give any confirmation.
More recent experiments were performed by Jackson and Collins (J-2) on two different scales of a Venturi aerator.
The writer feels that this method would be useful only in reaeration of relatively small discharges and volumes, as in waste treatment.
Pressure injection.-Thackston and Speece (T-15) review a method in which a small amount of the total water volume is supersaturated with air, under pressure, then released into the main flow. Air comes out of solution and reaerates the rest of the flow. No efficiencies were given.
Miscellaneous methods.-Thackston and Speece (T-16) report the use of a siphon which supplies spray nozzles downstream from a dam. Actual amounts of the DO increase were not given. Bulicek (B-30) describes an unsuccessful attempt to save fish by aerating a stream with paddle wheel steamers.
Hypolimnion reaeration. -Situations occur in which it is desirable to reaerate the bottom waters of a lake or reservoir without destroying the stratification by mixing. For example, where downstream releases are used for drinking water or maintenance of certain fish life it is beneficial to release cold water. One obvious wa~ to fill these needs is to selectively withdraw cold water from the reservoir, then reaerate the stream. The devices described thus far generally apply to this approach. Bernhardt (B-15) proposed a method by which reaeration of the hypolimnion could be accomplished within the reservoir without destruction of the thermocline and eplilimnion. Efficiency was determined to be 2.1 lb/kwhr. The corresponding transfer efficiency was 50 percent, based on measurement of the oxygen content of the rising bubbles.
17
The system includes an open-ended vertical pipe which extends from near the bottom of the reservoir to above the water surface. Air is introduced through a diffuser at the bottom of the pipe. Four distribution pipes, branching from the vertical pipe, are located just below the thermocline. The rising air causes the water within the pipe to rise, then flow outward through the distribution pipe. The vertical pipe extends far enough above the surface so that water is unable to overflow at the top.
Bernhardt's paper also includes a short summary table of reoxygenation capacity for several reservoir aeration systems. A condensed version of this table is given below:
Table 1
EFFICIENCIES OF SEVERAL REAERATION DEVICES
Method
Diffused air, mixing Mechanical turbine aerators Mechanical pump, mixing Aerohydraulic gun Hypolimnion aeration and mixing
Efficiency (lb/kwhr)
*0.3-4.3 1.3-5.6 1.0 1.4 2.1
*Transport of water to surface allows atmospheric reaeration in addition to oxygen transfer from bubbles.
Reaeration by reservoir mixing.-lmprovement of reservoir water quality by artificial destratification, using either compressed air or mechanical pumping, has been described by Symons, et al (S-42-S-49). Before using this approach, the necessity and desirability of destratification must first be determined. In many cases, stratification may be determined to be beneficial; for example, in con_trolling the temperature of downstream releases. Also, the work described has been limited to relatively small impoundments (less than about 5,000 acre-feet). Energy requirements for mixing large reservoirs might be prohibitive. However, mixing of selected zonces of reservoirs might prove to be economically feasible.
A recent paper by Symons, Carswell, and Robeck (S-49) describes test destratification of reservoirs up to 2,900-acre-feet volume using either mechanical or diffused air pumping. Results from one test showed reoxygenation efficiencies of 0.7 lb/kwhr for mechanical pumping and 1.7 lb/kwhr for diffused air pumping.
Reaeration with Molecular Oxygen
Molecular oxygen has a solubility in water approximately five times greater than oxygen in equilibrium with air. Therefore, correspondingly smaller amounts of molecular oxygen are required for reaeration. However, molecular (or tonnage) oxygen must be manufactured, and the advantage of less quantity might be offset by higher unit cost. Where dissolved nitrogen might have adverse effects on fish, use of molecular oxygen instead of air should be given special consideration.
18
Amberg, et al (A-7, A-8, A-9) discuss injection of molecular oxygen into a Pelton turbine. Separate runs were made using air or molecular oxygen. A single vent was placed directly above the runner blade, or a sparge ring above the runner blade was used.
The average results were as follows:
Single vent, air: Initial DO= 8.9 ppm Added 0.529 lb oxygen/kwhr
(0. 71 lb/hp-hr) of power loss
Single vent, oxygen: Initial DO= 7.2 ppm Added 13.9 lb/kwhr
(18.6 lb/hp-hr) Sparge ring, oxygen: Initial DO= 7.8 ppm
Result not clear
Turbine vibration was noted with the single vent, but not with the sparge ring.
Speece (S-22) discusses several sources of information which indicate absorption efficiencies ranging from 14 to 55 percent for various methods. He suggests that the cost of molecular oxygen depends upon the quantity used and whether the demand is seasonal or continual.
The cost for large quantities used throughout the year is estimated at $7-8/ton. For a 3-month-per-year operation, the cost might be $20-60/ton, with the cost proportional to the amount used. About 350 kwhr of power are required to produce 1 ton of oxygen. Speece states that for a year-around usage of 20 tons or more of oxygen per day, it would be economical to place an oxygen plant on the site of use. This reference reviews several theories of oxygen transfer and discusses several methods of introducing pure oxygen to water, including a downflow bubble contact system and injection into penstocks.
With injection into penstocks, the initial bubbles should be sized so that oxygen transfer can be essentially complete before reaching the turbine. Free bubbles can have an adverse effect on turbine operation.
Injection of molecular oxygen bubbles from a diffuser at the bottom of a reservoir has been suggested. The bubbles would be sized so that most of the oxygen transfer would be accomplished within the hypolimnion. Thus, the stratification would not be disturbed.
Use of liquid oxygen (LOX) is being investigated, but has not yet been reported.
Investigations of the use of molecular oxygen for reaeration are relatively recent. This technique should, in the writer's opinion, be investigated thoroughly for possible application to Bureau of Reclamation problems.
Overall Comparison of Artificial Reaeration Methods
Efficiencies of several reaeration devices were compared in Table 1. Table 2 summarizes efficiencies (in lb oxygen/kwhr), advantages and disadvantages of the various devices and methods which have been discussed. Obviously, it is difficult or impossible to make an evaluation on the basis of efficiencies alone. The efficiency is strongly dependent upon the initial DO deficit which is not always stated in the references. Also, Table 2 shows that the ranges of efficiencies are quite similar for the various methods.
Therefore, choices must be made on the basis of other factors such as the required application, the advantages and disadvantages of use, first cost, and maintenance cost. Relative costs are indicated under advantages and disadvantages for some of the methods listed in Table 2.
Thackston and Speece (T-15) present a limited comparison of annual costs of reaeration by diffusers, turbine injection, cascade aeration, and mechanical surface aerators. This comparison is given in Table 3.
The cost of turbine aeration assumes an efficiency of 3.5 lb/kwhr and a power value of 1 cent/kwhr. The capital costs for all methods are converted to annual costs by using a 5-percent interest rate and 20-year life. The sources of data are given in (T-15).
Imhoff (1-5) reports the comparative costs of three alternative methods applied to the Ruhr River in Germany:
Mechanical aeration
Turbine aeration
Treatment plant expansion
0.81 DM* for removal of organic pollution of one population equivalent
0.22 OM per population equivalent
4.0 OM per population equivalent
*German currency 4 OM~ $1.00 U.S.
Mechanical aeration was found to be 3.7 times more costly than turbine aeration (Table 3 shows a factor of 3.1). The marked advantage of instream aeration over treatment plant expansion in this case should be noted.
Krenke!, as part of unpublished seminar notes on reaeration, has provided a summary of costs of aeration systems determined by Bernhardt. This summary is reproduced in Table 4.
Table 4 shows that cascades (constructed only for the reaeration benefit) are not as competitive as suggested by Table 3, due to their relatively low oxygenation capacity. The cascade listed in Table 4 also had a relatively very low first cost. Both Tables 3 and 4 show that turbine aeration is very competitive. Bernhardt's hypolimnion aeration method is the next most competitive of the methods listed in Table 4, followed by floating aerators, U-tubes, turbo oxyders, cascades, and diffusers.
19
Whipple and Coughlin (W-11), in a recent paper, describe tests on the Passaic River, New Jersey, conducted for the purpose of comparing costs of mechanical aerators and diffusers. The efficiency of the mechanical aerator varied from approximately 2.0 to 3.0 lb/hp-hr (2.7 to 4.0 lb/kwhr), increasing with an increase in stream discharge. The transfer rates of the diffusers were about two-thirds those of the mechanical aerators under comparable conditions. Table 4 indicates similar results.
Complete cost analyses were made for multiple unit installations of either mechanical aerators or diffusers. The total annual costs showed that the mechanical aerators had a marked advantage.
The paper also includes a brief discussion of the possible environmental effects of aeration installations.
Other Applications of Reaeration Methods
Cavitation control.-ln 1963 Robertson ( R-9) suggested that the effect of gas or air content on cavitation was the least understood of any of the scaling factors in cavitation testing. There is little evidence that the situation has changed since that time. Robertson's discussion includes the "pseudo-cavitation" which can occur above vapor pressure due to the release of dissolved gases at low pressures.
It is generally accepted that true cavitation results from the growth and collapse of gas nuclei other than free bubbles. The necessary nuclei are believed to originate
Table 2
OVERALL COMPARISON OF REAERATION METHODS
Device Efficiency Advantages Disadvantages
Diffusers 2-8 percent (Est. Many types available. Clogging. Requires filtering (including 1-3 lb/kwhr) of air. Relatively low trans-reservoir fer efficiency. High first mixing) cost.
Mechanical 2-51b/kwhr Many types available. Natural or Swimming hazard. Obstructs aerators forced-air admission. Valves, channel. High first cost.
piping, blowers, etc., are not required.
Turbine 2-6 lb/kwhr (with Natural or forced-air admission. Possible power loss and adverse injection admission by Large discharges. Low first effects on turbine perform-
natural draft) cost, low maintenance cost. ance. Restricted to sites with hydroplants.
Venturi tubes 2-3 lb/kwhr Natural or forced-air admission. Head loss. Small discharges.
Cascades Determined from Maintenance free. Often associated Head loss may not be allowable. empirical formula with energy dissipation. Large High first cost. Low transfer (Low, see Table 4). discharges. No auxiliary equip- efficiency.
ment required.
U-tubes 1-5 lb/kwhr Natural or forced air admission. Not yet proven for large dis-Low maintenance cost. High charges. Possible plugging surface transfer, longer contact with debris or ice. time, increased deficit due to pressurization. Can be used in channel.
Hydraulic guns ~21b/kwhr Efficient mixing, high surface Primarily for mixing. Large currents, surface boil. bubble size, low transfer
efficiency.
Pressure No data available. Small volumes injection
Fixed-cone valves No power use or loss Associated with required energy Requires reservoir releases, is involved. dissipation. Large volumes. No which may not be possible.
auxiliary equipment required.
Mechanical pump k 1 lb/kwhr Simple equipment. Minimal mainte- Primarily for mixing. Low trans-
mixing nance. fer efficiency. Verified only for relatively small volumes.
Hypolimnion t> 2 lb/kwhr Allows stratification to remain Relatively low transfer
reaerati on and undisturbed. efficiency.
mixing
Molecular ~ 4-55 percent Can be used with various types of High cost of molecular oxygen.
oxygen contact devices. High transfer efficiency. No dissolved nitrogen.
20
Table 3 [From Ref (T-15)]
ANNUAL COSTS OF REAERATION*
Cost for diffused-air Cost for turbine Cost for cascade Cost for mechanical Type of cost aeration ($) aeration ($) aeration ($) aeration ($)
Capital cost 39,000 3,000 30,000 50,000 Per year 3,130 240 2,400 4,000
Annual operating cost 5,150 2,570 - 4,500
TOTAL 8,280 2,810 2,400 8,500
*Conditions for computation are: 10,000 lb oxygen/day /1,000 cfs ( 16 kg/day /100 cu m/sec) or 1.86 mg/1, for 90 days.
21
,..., 1\)
Oxygenation capacity* (kg/hr) Capital costs (OM) 1
(year of construction) Relative capital costs*
(OM/kg 02/hr) Energy consumption*
(kwhr /kg 02)
Total costs** (OM/kg 02)
Reference
140M ~ $1 .00. 2 Exact reference unknown. *With 50 percent DO deficit.
Table 4
COSTS OF APPLIED AERATION SYSTEMS
Air hoses Air pipes Cascade (diffusers) (diffusers) Reservoir U-tube
(weir) Baldeney Lippe circulation aerator
0.88 28 22 16 4.1 5,000 66,000 110,000 15,000 16,000 (1965) (1965) (1965) (1964) (1958) 5,700 2,360 5,000 940 4,000
0.85 ***6.60 3.45 2.40 0.67 (gravity (gravity flow) flow)
0.87 0.99 1.05 0.37 0.62 (gravity (gravity flow) flow)
Bock and Imhoff Lon dong )3ernhardt Bruijn and Schmidt -1968 1967 1963 and Tuinzaad 2 1965 (1-5) ( L-16) 1967 1958
(B-15) (B-28)
**With 50 percent DO deficit, operating 30 days per year, 1 0-year I ife, and 0.1 0 DM/kwhr. ***Due to local conditions compressed air with 4.5 kg/cm2 is used.
Turbine injec-tion system Floating Turbo
Baldeney aerator oxyder
120 41 13 34,000 95,000 44,000 (1967) (1965) (1967) 283 2,300 3,280
0.98 1.52 2.0
0.14 0.51 0.65
Imhoff Imhoff -1968 1968 (1-5) (1-5)
·in cracks and crevices of construction materials, as explained by Johnson (J-9).
Tullis and Skinner (T-31 ), in a discussion of cavitation in valves, suggest three possible solutions for controlling cavitation:
1. Eliminating the nuclei or reducing their size.
2. Eliminating the pressure recovery which causes collapse of the cavities.
3. Eliminating the low-pressure zones in which the nuclei grow into vapor cavities.
The third solution is practical and has been used extensively for controlling cavitation in gates and valves, on turbine runners, and in high-velocity chutes and free tunnels. Cavitation is controlled by placing air in the low-pressure zone to raise the pressure above that required for growth of the cavities. Also, cavitation damage is reduced in the pressure recovery zone because of the presence of free air to cushion the effects of cavity collapse.
The preceding discussion leads to the conclusion that dissolved air has no effect on either cavitation or cavitation damage. However, it seems to the writer that the presence of dissolved air could lead to the presence of free air because of dissolution in low-pressure areas of the flow, as in "pseudo-cavitation." Whether this free air would provide protection is not clear. Therefore, it could be concluded that the amount of dissolved air and the conditions in which it exists would determine whether it would be beneficial or deleterious.
Dijkman and Vrengdenhil (D-9) studied the effect of dissolved gas on water-column separation. They assumed that the gas comes out of solution and collects in a single cavity at the top of the pipeline. Upon an increase in pressure, that cavity compresses or collapses. Their mathematical analysis predicts that, in the presence of dissolved gas, the pressure rise after compression of the cavity is lower than that for water without dissolved gas.
Panaiotti (P-2), in experiments on a cylindrical profile for application to problems of cavitation in pumps, found that variations in gas content of the water had no practical effect on cavitation.
Velocity and discharge control. -Reference (T-3) describes the use of a diffused air curtain for controlling the velocity of flow leaving a treatment
plant grit removal chamber. Such an arrangement can have the dual purpose of reaeration and discharge control.
Removal of suspended matter.-Diffused air is used in sewage treatment for the removal of grit (A-2). The air is used to scour organic material from the grit, thus allowing the heavier grit to sink to the floor of the basin for removal. Also, a flotation process is used in which minute air bubbles an~ used to float suspended solids to the surface (E-10). The liquid is first supersaturated with air, then the pressure is reduced to produce the required small bubbles of free air. A similar process might have application in hydraulic engineering for removal of suspended sediments or other undesirable materials (S-11, S-12).
23
Fish controi.-Curtains of diffused air have been used for controlling the movement of fish in the vicinity of separation facilities and fish ladders.
Ice controi.-Diffused air has been used for some time to prevent ice formation in reservoirs (H-9, L-1, S-17). This is essentially a mixing application, in which warmer water is circulated from the bottom of a body of water to the surface during subfreezing air tern peratu res.
Control of surface pollutants.-The use of air curtains has been proposed for use in blocking the movement of surface pollutants, such as oil slicks (G-10).
Evaporation controi.-Streif (S-37) proposed using compressed air to bring cold reservoir bottom waters to the surface, thus reducing evaporation losses. A measurable reduction in evaporation is reported by Koberg ( K-18).
INSTRUMENTATION
The Winkler method (-2, H-21) is commonly used for laboratory analysis of dissolved oxygen. Within the past several years, electronic instrumentation has become available for this purpose. As pointed out by Wood (W-25), sensors have the advantages of (1) elimination of preparation and standardization of reagent solution, (2) reduced analysis time, (3) a less tedious method, and (4) excellent correlation with the Winkler method. A wide variety of sensors is available from a number of manufacturers. However, the reader should be cautioned that experience to date has shown that electronic equipment may not maintain calibration over a period of a few days.
RESEARCH NEEDS
Reported Research
The review has indicated considerable past research activity in:
Natural reaeration in streams, reservoirs, and estuaries, including dispersion in streams
Oxygen depletion by organic decay and nitrification Design and performance of diffusers and mechanical
aerators for waste treatment applications Bubble dynamics Mathematical simulation of reaeration and oxygen
depletion
Some research has been done concerning:
Use of diffusers, mechanical aerators, and other devices for reaerating large volumes of water such as for in-stream reaeration and reservoir reaeration and mixing
Use of molecular oxygen Comparative costs of reaeration methods and
devices Reaeration efficiency of turbine injection Effects of air injection on turbine performance Air injection for cavitation control, velocity and
discharge control, removal of suspended matter, and other miscellaneous applications
Evaluation of outlet control valves for reaeration capability
Reoxygenation by photosynthesis Reaeration at cascades Use of radioactive tracers in field studies Development of instrumentation Development of U-tube aeration Turbulent mixing in surface aeration
Current Research Activity
Research, as yet unreported, is currently underway in several areas including:
Natural stream reaeration Reaeration by photosynthesis Mathematical simulation Induced mixing by air Field eva I uations of reaeration Use of molecular oxygen, including liquid oxygen Oxygen transf~r to water droplets Flow surface protection against cavitation Diffusion away from free surface
24
Nitrogen and ammonia removal Design of aeration devices Use of radioactive gas tracers in field studies Foam separation of suspended materials Effects of audio vibrations on oxygen transfer rates Ice control Aeration with recycled foam Concentration of streamflow to mechanical aerators Stream oxygen balance Removal of metals from acid mine discharge by
foam fractionation Spraying water into pressurized tank of pure oxygen
or air Study of nucleus formation in cavitation Influence of surface mixing downstream from
surface aerators Economics of water quality management programs,
including reaeration Reaeration efficiency of Howeii-Bunger valves Precipitation of metallic elements
Suggestions for Future Research
The review has indicated a need for new or additional research in the following areas, in order of their importance:
a. Correlation of the reaeration rate constant, k2, with flow parameters. A fresh approach appears to be needed.
b. Development of a method to determine true efficiency of reaeration devices, perhaps by assignment of a k2 for each device. Elimination or isolation of factors which modify experimental measurements and cause inaccurate evaluation of actual amount of oxygen added.
c. Comparative economic analyses of aeration methods and devices. Development of guidelines to allow comparisons on the basis of cost per unit of dissolved oxygen increase.
d. Development of new methods and devices for reaeration. Testing of promising methods and devices developed by others. Continuing review of research activity by others.
e. Additional field testing and evaluation of injection of air or oxygen into turbines.
f. Evaluation of energy dissipators, gates, and valves for reaeration capability. Field testing of prototype structures.
g. Determination of modifications for existing structures to improve reaeration characteristics. Laboratory and field tests.
h. Study of the effects of dissolved air on cavitation on high-velocity flow surfaces.
25
i. Development of miscellaneous engineering uses of injection of air into water.
GLOSSARY OF TERMS
~lgae-a one-celled photosynthetic microscopic plant.
benthic-refers to the bottom of lakes and reservoirs.
biota-all the living organisms in a given region.
BOD-biochemical oxygen demand, amount of oxygen required for biological oxidation of organic matter.
diffusion-transport due to the difference between true convection and the time average of convection, movement of a species in a mixture from a point of higher concentration to a point of lower concentration.
diffusivity-molecular diffusion coefficient, time rate of diffusion.
dispersion-transport due to variations in longitudinal velocity in a cross section.
dissolved oxygen saturation deficit-the difference between the amount of dissolved oxygen present in a solution at a given temperature and the amount which would be present for a saturated condition at the same tern perature.
dystrophic-lakes or reservoirs with very low lime content and very high humus content which often lack nutrients.
epilimnion-the upper layer of a stratified lake or reservoir, from the surface to the thermocline, usually mixed.
27
eutrophic-having an abundance of aquatic plant growth such as algae due to overenrichment with nutrients such as nitrogen and phosphorus.
hypolimnion-the bottom layer of a stratified lake or reservoir, from the thermocline to the bottom, isolated from surface influence.
isotropic turbulence-statistically independent of the orientation and location of the coordinate axes of velocity measurement.
molecular (tonnage) oxygen-pure oxygen, the molecular state, 02.
nitrification-transformation of ammonia nitrogen to nitrates.
oligotrophic-lakes or reservoirs with a small supply of nutrients.
oxygen sag-a curve which depicts the concentration of dissolved oxygen along a stream.
photosynthesis-the natural process by which light and chlorophyll are used by plants to synthesize carbohydrates from C~ and water; oxygen is produced in the process.
respiration-process by which living organisms take in oxygen from air or water.
sparge ring-a circular diffuser for the introduction of air into mechanical aerators or hydraulic turbines.
stratification-a vertical variation in temperature, dissolved oxygen, chemicals, turbidity, etc., in a stream, lake, or reservoir.
a a A A' b b C,c c Co Cs Ct 'Y de D D' DL Om, DAB Do E E Ea f g Gs h H 8 k K1 or k1 K2 or k2 Kd KL KLa L L La m n n N p Pe q
r R Re p Sc Se Sh SR
DEFINITIONS OF MATHEMATICAL TERMS
coefficient of water quality in weir equations, dimensionless ratio of bubble or water surface area to liquid volume, L -1 bubble or water surface area, L 2 molecular collision factor, T-1 coefficient of weir configuration, dimensionless film thickness, L a constant concentration, M/L3 initial concentration, M/L 3 saturation concentration or solubility, M/L 3 concentration at timet, M/L3 specific weight, M/ L 3 equivalent bubble diameter, L oxygen deficit, M/L 3 bubble diameter, L longitudinal mixing coefficient, L 2;T molecular diffusion coefficient, L2/T initial oxygen deficit, M/L 3 rate of energy dissipation per unit mass, L 2;T3 diffuser efficiency, percent energy required by molecule to be included in reaction, ML2/T3 mole friction factor, dimensionless acceleration of gravity, L/T2 airflow, L 3;T weir free fall height, L depth of flow, L temperature correction constant, dimensionless reaction rate, T-1 BOD rate constant, T-1 reaeration rate constant, T-1 an exponent, dimensionless liquidcfilm coefficient, L/T overall transfer coefficient, T-1 liquid film thickness, L BOD, M/L3 initial BOD, M/L3
=mass, M exponent, function of bubble size, dimensionless rate of mass transfer, M/L 2_ T mechanical aeration efficiency, M/LFT power use, L F Peclet number, dimensionless transfer rate, M/T ratio of upstream deficit to downstream deficit for weirs, dimensionless rate of renewal of liquid film, T-1 universal gas constant, M L 2;T2 per mole-°K bubble Reynolds number, dimensionless mass density, M/L 3 Schmidt number, dimensionless energy gradient, dimensionless Sherwood number, dimensionless oxygen supply rate, MIT
29
DEFINITIONS OF MATHEMATICAL TERMS-Continued
t time, T t' time of one cycle of absorption and mixing, T texp time of bubble exposure, T T temperature, degrees TR oxygen transfer rate, M/T u average velocity, L/T v bubble or liquid velocity, L/T V liquid volume, L 3 vt terminal bubble velocity, L/T v kinematic viscositv
3 L 2;T
W system capacity, L W mass fraction, dimensionless x distance, L
30
BIBLIOGRAPHY PREFACE
This bibliography represents a sincere attempt by the writer to prepare a comprehensive list of references on the
sut;)ject of reaeration. Undoubtedly, some important references have been inadvertently omitted, while some
references of questionable value have been included.
Not all of the references were available to the writer for personal review. In some cases, summaries by others were
studied and, where appropriate, the information contained therein was included in this report.
The subject index which follows the bibliography was based on abstracts, annotations, or titles of the references
wherever possible.
31
-1
-2
-3
Anon COMPRESSED AIR HANDBOOK Compressed Air and Gas Institute New York NY 1947
Contains data on characteristics of air blowers
Anon STANDARD METHODS FOR THE EXAMINATION OF WATER
AND WASTEWATER 11th Edition American Public Health Assoc New York NY 1960
Anon AERATION OF LARGE VOLUMES OF WATER Water and Waste Treatment J (Brit) v7 1960 p 508 Water Pollution Abstracts (Brit) v 34 1961 p 37
Describes in very general terms a system which injects compressed air into flow pumped from thermal power station cooling water discharge. Supersaturated flow is returned to main flow where surplus air comes out of solution for reaeration of the entire flow
-4 Anon NEW Ll FE FOR POLLUTED SWEDISH LAKES Water Waste Treatment J v 8 1960 p 65 Water Pollution Abstracts v 40 1961 p 941
Reports on using compressed air to destratify polluted Swedish lakes; in 3 weeks oxygen content increased from 0 to 57 percent, new plant I ife appeared, and the original temperature differential of 12° C disappeared
-5 Anon FLOATING PUMP FIGHTS POLLUTION Chern Eng v 69 n 17 1962 p 70
-6 Anon SWEETENING A SMELLY RIVER WITH OXYGEN Eng News-Record v 169 n 2 1962 p 42
-7 Anon STREAMFLOW REGULATION FOR QUALITY CONTROL Robert A Taft Sanitary Eng Center Cincinnati Ohio Apr 3-5 1963
-8 Anon REVIEW OF LITERATURE OF 1963-1968 ON WASTEWATER AND WATER POLLUTION CONTROL
Water Pollution Control Federal J v 36 n 7 Ju I 1 964 p 791 v 37 n 7 Jul 1965 p 887 v 38 n 7 Ju I 1 966 p 1 049 v 39 n 7 Ju I 1 967 p 1 049 v 40 n 6 Ju n 1 968 p 897 v 41 n 6 Jun 1969 p 873 Reviews and separates bibliographies of I iterature on water pollution; including stream self-purification in relation to oxygen sag
35
EQUIPMENT diffusers
DO ANALYSIS
EQUIPMENT reservoirs pressure
injection
EQUIPMENT reservoirs diffusers
EQUIPMENT reservoirs pumps
EQUIPMENT streams
BASIC STUDIES streams experimental
GENERAL reviews
-9
-10
-11
Anon LAGOON AERATION SYSTEM BUBBLES AWAY WASTE TREATMENT PROBLEMS
World Construction v 20 n 3 Mar 1967 p 19-21 Air-Aqua grid system, originally designed for small community treatment plants, was installed in lagoons of Regina, Saskatchewan, plant to eliminate odor problems; in action and performance this system can be compared to fast-moving stream where rolling motion brings oxygen down to bottom water and also brings oxygen-deficient up to surface; installation and general details of system; 30 blowers with 30-hp motors provide air; blowers are mounted on 11-ft concrete piers to prevent movement in winter ( El 1967)
Anon OXYGEN SPEEDS UP WASTE TREATMENT lnd Eng Chern v 61 n 2, 5-6
The use of oxygen instead of air to gain maximal efficiency from the activated-sludge process is discussed. Union Carbide is to run a full-scale test for their process at the Batavia, N.Y., sewage works. The same influent stream will feed a normal aeration tank and an aeration tank supplied with oxygen, so that a direct comparison of performance can be made (Publ Wks NY 1969 v 100 n 3 p 118) (WPA 1625 Aug 1969)
Anon SILICONE RUBBER FOR MEMBRANE LUNG Nature v 224 n 5217 Oct 1969 p 301-302
Reports the development of silicone rubber membranes said to have potential applications in oxygenating blood in heart-lung machines, underwater breathing apparatus, and water desalting; membrane has high permeability to gases with a selective permeability to carbon dioxide in solution 12 times greater than for oxygen
36
EQUIPMENT waste treatment diffusers
EQUIPMENT waste treatment molecular oxygen
EQUIPMENT mise equipment
A
A-1 Adeney, WE Becker, H G THE DETERMINATION OF THE RATE OF SOLUTION OF
ATMOSPHERIC NITROGEN AND OXYGEN BY WATER Philosophical Magazine s 6 v 38 n 225 Sep 1919; v 39 n 232 Apr 1920
A-2 Albrecht, A E AERATED GRIT OPERATION DESIGN AND CHAMBER Water and Sewage Works v 114 n 9 Sep 1967 p 331-335
Experimental program established to determine satisfactory method for controlling grit chamber hydraulics; if properly designed, aerated grit chambers will exhibit certain advantages over conventional grit chambers; long, narrow chamber design, incorporating longitudinal baffle, was developed; this chamber design provides 95 percent removal of 60 mesh grit (specific gravity 2.6); organic matter content of this grit would be approximately 5 percent (EI 1968)
A-3 AI brecht, D BELUFTUNG DES RUHRWASSERS AM WEHR SPI LLENBURG (Aeration of the Ruhr Water at Spillenburg Weir)
Die Wasserwirtschaft 1968 Heft 11 In German
A-4 Albrecht, Detlef SCHATZUNG DER SAUERSTOFFZUFUHR WEHRE UNO KASKADEN
(Aeration of Water by Weirs and Cascades) Wasserwirtschaft v 59 n 11 Nov 1969 p 321-323
Discusses the use of cascades for artificial aeration and the increase in oxygen at existing weirs and cascades In German
A-5 AI-Saffar, Adnan Mustafa EDDY DIFFUSION AND MASS TRANSFER iN OPEN-CHANNEL
FLOW PhD Thesis U of Calif Berkeley 1964
A-6 Amand, M T PREDICTING DISSOLVED OXYGEN CONCENTRATION IN A
LAKE COVERED WITH EVAPORATION SUPPRESSANT J Water Pollution Control Federation v 40 n 11 Nov 1968 p R423-R433
Diffusion of oxygen from the atmosphere through a monomolecular film of a hexadecanol-octadecanol mixture was investigated under quiescent conditions. The study revealed that the oxygen-uptake rate of organisms in water can be measured and used to predict the lowest dissolved oxygen concentration in water during early morning hours when oxygen concentration is most critical. Oxygen-transfer rates in distilled water at 21° and 36° C treated with a monomolecular film were 74 and 84 percent, respectively, of the rates for untreated distilled water. Treated pond water containing 194 mg/1 dissolved solids showed oxygen-transfer rates of 89.6 and 92.6 percent at 21° and 36° C, respectively, as compared with untreated pond water. An equation for the temperature dependance of rate coefficients for treated and untreated water is given. Theoretical and measured values for minimum dissolved oxygen agree closely
37
BASIC STUDIES experimental reaeration
EQUIPMENT waste treatment mise uses
EQUIPMENT streams cascades
EQUIPMENT streams cascades
BASIC STUDIES streams experimental reaeration
BASIC STUDIES reservoirs reaeration
A-7
A-8
A-9
A-10
A -Continued
Amberg, H R Cormack, L F Funk, W Rosenfeld, AS Blosser, R 0 RE-AERATION OF STREAMS WITH MOLECULR OXYGEN lnd Water Eng v 4 n 2 Feb 1967 p 15-20
Artificial stream aeration is a promising method for alleviating critically low dissolved oxygen levels in streams. Stream aeration using air has been studied and used widely, but no .experimental work has been reported on the use of tonnage oxygen. Aeration efficiency with air is very poor as the saturation level is approached, and this problem can be overcome by using oxygen. Experiments on the feasibility of using oxygen were conducted at a power turbine at Willamette Falls, Oregon, by venting the turbine with air and oxygen. The first run was with air, and the second with oxygen. Another oxygen trial was made using a multiple-diffuser sparge ring encircling the turbine above the runner blade. Experimental procedures and results are discussed and oxygen stream aeration systems are compared on the bases of efficiencies, costs, and effect on turbine operation
Amberg, H R and others STREAM REAERATION USING TONNAGE OXYGEN presented to the Regional Meeting of the National Council for Stream
Improvement Crown Zellerbach Corp Portland Oreg Sep 1967 Compared efficiency of injection of air or molecular oxygen above runner blade of Pelton turbine with single vent injection and sparge ring injection. Data on power loss and cost of oxygen are presented. Vibration of turbine resulting from injection is discussed
Amberg, H R Wise, D W Aspitarte, T R AERATION OF STREAMS WITH AIR AND MOLECULAR OXYGEN Tappi v 52 n 10 Oct 1969 pp 1866-71
Results are given on full-scale river aeration by two methods (a) release of oxygen into hydroelectric turbines, and (b) diffusion of gaseous oxygen into water under pressure. Oxygen is approximately five times as effective as an equal quantity of air in imparting dissolved oxygen to streams. The authors consider that provided the oxygen is procured at $30 per ton dissolved oxygen can be added to the water at a total cost of 3 to 4 cents per pound
Ambuhl, H THE PRACTICAL APPLICATION OF THE ELECTROCHEMICAL
DETERMINATION OF OXYGEN IN WATER Schweizerische Zeitschrift fur Hydrol v 22 Fasc 1 1960 p 23-29
Transl from German USBR No 614 A commercial limnological probe was developed for the remote simultaneous determination of temperature, oxygen, and conductivity by electrochemical methods. The fundamentals of electrochemical methods and technical details involved in the selection of instrumentation systems are discussed. Some basic features of the probe include: (1) cable coupling arrangement to make possible the use of cables of different lengths; (2) temperature measurements made with a thermistor sensor and an alternating-current-powered Wheatstone bridge; (3) simultaneous determination of resistivity and conductivity. Conductivity is measured directly by rearranging bridge members and measuring the reciprocal resistance. Conductivity 'may be measured continuously, but temperature effects must be compensated. Automatic temperature compensation is technically feasible, but is presently uneconomical; and (4) measurement of high and low oxygen contents. Low oxygen contents are determined by measuring only the diffusion currents at
38
EQUIPMENT streams turbine injection molecular oxygen
EQUIPMENT streams turbine injection molecular oxygen
EQUIPMENT streams turbine injection diffusers molecular oxygen
DO ANALYSIS instrumentation
A-11
A-Continued
the electrodes. High oxygen contents are determined potentiometrically by supplying an auxiliary voltage to the electrodes. The step-by-step operation of the instrument is covered in detail
Anderson, C A AERATION RECOVERY OF LANOLIN FROM WOOL SCOUR
LIQUOR Textile Res J v 30 1960 p 51-57
Investigation of the aeration process has resulted in an improved design for a continuous recovery plant. On a pilot scale the design has permitted throughput rates about 2-1/2 times greater than previous designs, with equal recovery efficiencies. ( Livengood-N C) W69-1 0286
A-12 Angelino, H HYDRODYNAMIQUE DES GROSSES BULLES DANS LES
LIQUJDES VISQUEUX Chern Eng Sci v 21 n 6-7 Jun-Jul1966 p 541-550
Hydrodynamics of large bubbles in viscous liquids; with four columns of diameter between 10 and 40 em, it has been possible to make systematic study of rising motion of air bubbles of various volume through liquids of different viscosity; evolution of bubble's shape with increasing volume is studied, and relation between frontal diameter and volume is proposed; study is made of influence upon velocity of ascension of proximity of walls. 28 refs. In French (EI 1967)
A-13 Aris, R ON THE DISPERSION OF A SOLUTE IN A FLUID
FLOWING THROUGH A TUBE Proc Royal Society of London v 235A 1956 p 67
39
EQUIPMENT waste treatment
EQUIPMENT diffusers
BASIC STUDIES experimental reaeration
B-1
8-2
B-3
B-4
B-5
B
Baars, J K Muskat, J OXYGENATION OF WATER BY BLADED ROTORS J and Proc I nst Sewage Purif (Brit) pt 5 1963 p 454
Bain, Richard C Jr PREDICTING DO VARIATIONS CAUSED BY ALGAE Proc ASCE V 94 n SA 5 1968 p 867-881
Eutrophic environments are often dominated by planktonic algal populations (phytoplankton.) which can cause diurnal variations in DO concentrations through respiratory activity and photosynthesis. Photosynthetic oxygenation and respiratory deoxygenation rates of estuarine phytoplankton were measured at various standing crop (chlorophyll) levels. Oxygen production and consumption rates for actively growing phytoplankton populations were related to standing crop at 20° C and nonlimiting light. Variations in algal photosynthetic production rate, as related to light adaption, age of cells, nutrition, temperature, and algal type, are considered. The Streeter-Phelps equation was modified to include phytoplankton production and respiration rates in formulations designed to predict DO concentrations over a 24-hr period. An example is given and the resulting predictions are compared with field measurements from a tidal reach of the San Joaquin River, Calif
Barkov, N K VPUSK SZHATOGO VOZDUKHA V ZONU RABOCHEGO KOLESA
PRJ NESPOKOINOM REZHIME RABOTY RADIAL'NO-OSEVOI GIDROTURBINY
Energomashinostroenie n 4 Apr 1968 p 39-40 Injection of compressed air into runner section during perturbed operation of radial-axial hydraulic turbine; results are reported of experiments performed on turbine provided with system of 12 pipes, 50-mm diameter r~dially disposed on turbine hood and connected to 49-cu-m air receiver; compressed air at 5 to 8 atm pressure was injected under hood; ratio between air and water flow rate was 0.0462; besides effecting quiet operation of turbine, air injection reduced considerably blade area subject to cavitating erosion and increased service life of blades. In Russian (EI 1968)
Barnhart, Edwin L TRANSFER OF OXYGEN IN AQUEOUS SOLUTIONS Proc ASCE v 95 n SA 3 Jun 1969 p 645-661
The paper reports the results of studies which describe the influence of geometry and temperature on the liquid film coefficient, KL, and the mass transfer coefficient, KLa, for the transfer of oxygen from air bubbles rising in a liquid. It is shown that the liquid film coefficient is related to the total drag force operating at the liquid gas interface. The influence of several surface active agents on KL a and KL are reported. The study indicates that at low concentrations, the principle influence of surface active agents is their effect on the bubble size and rate of rise
Barrett, M J Gameson, A L H Ogden, C G AERATION STUDIES AT FOUR WEIR SYSTEMS Water and Water Eng (Brit) v 64 1960 p 407
Data from four weir systems with discharges from 1 to 500 mgd were used to verify an empirically derived predictive equation. Discusses effect of weir configuration (steps vs free weirs)
40
EQUIPMENT waste treatment mechanical aerators
BASIC STUDIES streams experimental photosynthesis respiration
EQUIPMENT streams turbine injection
BASIC STUDIES experimental reaeration
EQUIPMENT streams cascades
8-6
B-7
8-8
B-9
B-10
B-11
8-12
B-13
B-Continued
Bartsch, A F ALGAE AS A SOURCE OF OXYGEN IN WASTE TREATMENT Sewage and lnd Wastes v 33 1961 p 239-249
Batchelor, G K TURBULENT DIFFUSION Lecture Series No.4 U of Maryland College Park 1960
Bayley, R W Wyatt, K AERATION OF EFFLUENTS BY VENTURI TUBE Water and Waste Treatment J Nov-Dec 1961
Laboratory tests show effective aeration can be achieved by a Venturi tube by air bubbles introduced through holes in the throat of the Venturi; however predictions on performance of a full-size unit are not made because of other important factors
Beck, A J DIFFUSER PLATE STUDIES Sewage Works J 8 1936 p 22
Becker, H G MECHANISM OF ABSORPTION OF MODERATELY SOLUBLE GASES IN WATER
I nd Eng Chern v 1 6 1 924 p 1 220
Bella, D A Dobbins, WE DIFFERENCE MODELING OF STREAM POLLUTION Proc ASCE v 94 n SA 5 1968 p 995
Benjes, Henry H Jr McKinney, Ross E SPECIFYING AND EVALUATING AERATION EQUIPMENT Proc ASCE v 93 n SA 6 Dec 1967 p 55-64
One of the most complex aspects of designing a modern activated sludge waste water treatment system is concerned with the selection of optimum aeration equipment. A performance evaluation for initial operating conditions has been developed which can be extrapolated to the design operating conditions. The performance evaluation requires determination of operating air-flow rates, temperature, mixed liquor suspended solids, oxygen demand rates, and dissolved oxygen. The application of the performance evaluation technique to the aeration equipment furnished for the Grand Island, Nebr., activa·~ed sludge plant is described. The experience obtained from the performance- evaluation at Grand Island has pointed to certain necessary refinements in the evaluation technique. A sample aeration equipment performance specification is appended incorporating these refinements
Bennett, G F Kempe, L L OXYGEN TRANSFER IN BIOLOGICAL SYSTEMS PURDUE U-Eng Extension Ser v 118 1965 p 435-449
Oxygen transfer rate in unsparged, but agitated system is shown less than rate in system that is both sparged and agitated simultaneously; differences between these measurements increase as gas-liquid interface or partial pressure of oxygen in gas is increased; data suggest two parallel paths for oxygen transfer from air to cell; in unsparged liquid, microorganism has available only oxygen dissolved in liquid; in sparged system, some cells adsorb
41
BASIC STUD! ES experimental photosynthesis
BASIC STUDIES
EQUIPMENT Venturis
EQUIPMENT waste treatment diffusers
BASIC STUDIES reaeration
BASIC STUDIES streams theoretical
EQUIPMENT waste treatment
BASIC STUDIES waste treatment experimental reaeration
B-14
B-15
B-16
B-17
B-18
B-Continued
on air bubbles, or air bubbles adsorb on cells; by this process, some resistance to oxygen transfer is promoted. 43 refs (EI 1967)
Bernhart, A P POWER OF SELF-PURIFICATION IN RIVERS EXEMPLIFIED
BY TORONTO'S DON RIVER Eng J v 48 n 2 Feb 1965 p 31-34
Water recovery in upper Don after pollution shock is indicated by fast reduction BOD, phosphates and coli bacteria as well as by increase in dissolved oxygen; lighter water color, improved conditions of streambed and reappearance of higher organisms also indicate strong self-purification (EI 1965)
Bernhardt, H AERATION OF WAHNBACH RESERVOIR WITHOUT CHANGING
TEMPERATURE PROFILE American Water Works Assoc J v 59 n 8 Aug 1967 p 943-964
Results of aeration tests on reservoir in Siegburg, West Germany, which contains 33,740 acre-ft, has maximum depth of 141ft, with its surface 410ft above sea level, are reported; tests showed among other things that aeration and mixing of impoundment are feasible and that complete destratification by diffused air bubble method and aeration of hypolimnion only both had favorable effect on water quality, but aeration of hypolimnion had additional advantage of preserving quantity of cold water for use as drinking water. 26 refs (E I 1967)
Beuthe, C G IMPROVEMENTS IN FINE-BUBBLE AERATION FROM THE STANDPOINTS OF TECHNIQUE AND OPERATION
Water Pollution Control London v 68 1969 p 51-58 The mathematical relations for activated-sludge tanks-- operating as homogeneous and heterogeneous reactors and with constant hydraulic loading (see Water Pollution Abstracts v 41 n 1649 1968) were tested by observing the performance of two plants equipped with tubular diffusers. The results indicate that for maximal efficiency an aeration tank should have longitudinal flow, constant sludge loading, and tapered aeration. The advantages of fine-bubble aeration by tubular diffusers over surface aeration are indicated (WPA 1382 Jul 1969)
Bewtra, J K Nicholas, W R BASIC VARIABLES OF OXYGENATION- FROM DIFFUSED AIR AERATION TANKS
presented at the 17th Annual Purdue lnd Wastes Conf 1962
Bewtra, J K Nicholas, W R OXYGENATION FROM DIFFUSED AIR IN AERATION
TANKS Water Pollution Control Federation J v 36 n 10 Oct 1964 p 1195-1224
Oxygen transfer studies conducted in 4-ft-long section of full-scale aeration tank at Philip F. Morgan Sanitary Engineering laboratory, State University of Iowa; variables of oxygen transfer from air to water were studied; variables are presented mathematically and their relative importance is discussed; development of oxygen transfer equation; effect of diffuser submergence on oxygenation; effect of aeration tank width on oxygenation. 24 refs ( E I 1965)
42
BASIC STUDIES streams experimental_ reaeration
EQUIPMENT reservoirs diffusers
EQUIPMENT, waste treatment diffusers
EQUIPMENT waste treatment diffusers
EQUIPMENT waste treatment diffusers
B-19
B-20
B-21
B-22
B-23
B-24
B-25
B-26
Bird, R 8 Stewart, W E Lightfoot, E N TRANSPORT PHENOMENA John Wiley and Sons, Inc N Y 1960
Bischofsberger Tofaute
B-Continued
POROUS PLASTICS FOR FINE BUBBLE AERATION OF WASTE WATERS
Tech Scientific Reports of the Ems Federation and the Lippe Assoc v 6 1964 p 26-43
Black, SA SUPPLEMENTARY AERATION OF WASTE STABILIZATION
PONDS FOR INDUSTRIAL WASTES Water and Pollution Control v 105 n 1 Jan 1968 p 30-31
Raw industrial and domestic wastes were contained in stabilization pond for treatment and used for operational and performance data collection and evaluation when aerated by surface mechanical-aeration device; method of study and results obtained; steps are suggested for effective treatment of waste (EI 1967)
Black, SA CAN AERATION PONDS POLISH SEWAGE PLANT EFFLUENT Water and Pollution Control v 105 n 6 Jun 1967 p 38, 40, 42
Effluent polishing pilot plant study was performed to evaluate polishing processes suitable to provide additional treatment to secondary treatment plant effluents in Ontario; pilot ·plant consisted of aeration pond and settling lagoon coupled in series; from study it was concluded that if certain design and operational requirements are met, .effluent with BOD. and suspended solids content not exceeding 8 ppm may be maintained by aeration pond; aeration pond should be followed by settling lagoon of 1 to 2 days' retention to raise dissolved oxygen of effluent to 4 ppm before its introduction to receiving stream (EI 1967)
Blain, W A McDannel, A J REAERATION MEASUREMENTS IN A EUTROPHIC STREAM Proc 22nd lnt Waste Conf Purdue U Ext Ser 129 1968 p 1044
Blodgett, J H AIR DIFFUSION WITH SARAN-WRAPPED TUBES Sewage and lnd Wastes v 22 1950 p 1290
Bohnke, B EFFECTS OF ORGANIC WASTEWATER AND COOLING WATER ON SELF-PURIFICATION OF WATERS
Proc 22nd lnd Waste Conf Purdue U Ext Ser 129 1968 p 752
Browning, Jon E 02 & 03-RX FOR POLLUTION? Chern Eng v 77 n 4 Feb 23 1970 p 46-48
New oxygenation and ozonation processes look prom1smg for waste treatment and water purification; gives brief descriptions and some costs for Linde's oxygenation municipal sewage treatment plant at Ratavia, N.Y.; Air Reduction Co.'s ozone system for tertiary waste treatment; Crown
43
GENERAL
EQUIPMENT waste treatment diffusers
EQUIPMENT waste treatment mechanical aerators
EQUIPMENT waste treatment
BASIC STUDIES streams experimental reaeration
EQUIPMENT waste treatment diffusers
BASIC STUDIES streams experimental reaeration
EQUIPMENT waste treatment
B-27
B-28
B-29
B-31
B-Continued
Zellerbach's oxygenation system for a paper mill at Bogalusa, La.; and Container Corp.'s oxygenation of paper mill waste water at Brewton, Ala
Bryan, J G IMPROVEMENT IN THE QUALITY OF RESERVOIR DISCHARGES THROUGH RESERVOIR MIXING AND AERATION
U S Dept Health Education Welfare Symposium on Streamflow Regulation for Quality Control Public Health Service Pub No 999-WP-30 Jun 1965 p 317-344
Describes the aerohydraulic gun and the aeration capacity and mixing produced by these guns. Examples of practical applications are given at Blelham Tarn, lnniscarra Reservoir, and Lock Turret Reservoir
Bruijn, Jacob Tuinzaad, Hendrick THE RELATIONSHIP BETWEEN DEPTH OF U-TUBES AND
THE AERATION PROCESS J American Water Works Assoc Jul 1958 p 879
Reports original development of U-tube oxygenation method- and describes prototype installation
Bryson, R A Sumoi, V E MIDSUMMER RENEWAL OF OXYGEN WITHIN THE
HYPOLIMNION J Marine Research v 10 1951 p 263-269
Bulicek, J ARTIFICIAL AERATION OF WATER IN THE MOLDAU
IMPOUNDING RESERVOIRS AND IN CZECHOSLOVAKIA Vodn Hospod v 9 1957 Czech WassP.rwirtschaft (Stuttgart) v 49 1959 p 25 Water Pollution Abstracts v 4Q 1 960 p 1910
Describes an unsuccessful attempt to save fish by aerating water with paddle-wheel steamers
Burdick, ME OPEN WATER IN WINTER Wisconsin Conservation Bull v 24 1959 p 21
Reports on compressed air mixing of lakes to prevent winterkill of fish when the lake freezes over and cuts off the oxygen supply
Burns, 0 B Jr Eckenfelder, W W Jr AERATION IMPROVEMENTS AND ADAPTION OF COOLING
TOWER TO ACTIVATED SLUDGE PLANT Tappi v 48 n 11 Nov 1965 p 96A-99A
Problems associated with high temperature of waste effluent during summer and inadequate aeration capacity were solved by installation of counter-flow cooling tower and by modification of aeration tanks; by these changes, plant overall efficiency is maintained in range from 85 to 90 percent and average final effluent BOD is improved from 43.9 to 25.4 ppm (EI 1966)
44
EQUIPMENT reservoirs hydraulic guns
EQUIPMENT streams U-tubes
EQUIPMENT reservoirs
EQUIPMENT streams mechanical
aerators
EQUIPMENT reservoirs diffusers· mise uses
EQUIPMENT waste treatment
B-33
B-34
B-35
B...:.Continued
Burns, 0 B Jr St. John, J P O'Connor, D J PILOT MECHANICAL AERATION STUDIES OF THE JACKSON RIVER IN COVINGTON, VIRGINIA
Proc 21st I nd Waste Conf Purdue U Ext Ser 121 1966 p 799 Describes use of plate-type surface aerator placed at location of minimum DO in stream. Efficiency of 2.15 lb oxygen/hp-hr for 1 00-percent DO deficit. Discussion of paper describes German use of floating surface aerators (1.75 lb oxygen/kwhr at 50-percent deficit), diffuser (5-percent efficiency at 50-percent deficit), and injection above runner of hydroturbine (efficiency not given)
Burrows, M G INHIBITION OF AERATION PROCESS: QUANTITATIVE ASSESSMENT OF SOME TOXIC MATERIALS
Water Pollution Control v 68 n 4 1969 p 457 The cost of treating industrial effluents containing inhibitors can be evaluated by using a laboratory activated sludge apparatus consisting of a set of aeration tanks into which a 30:20 effluent is added as control and, in other tanks, settled sewage containing 2 mg/1 of various inhibitors fed. After daily aeration cycles had been carried out for a week, the supernatant liquor was sampled and analyzed and performance evaluated in each case. The inhibitory effects of various metals and cyanide were tabulated
Butts, T A Schnepper, D H OXYGEN ABSORPTION IN STREAMS Water and Sewage Works v 114 1967 p 385
45
EQUIPMENT streams mechanical aerators
diffusers turbine injection
BASIC STUDIES waste treatment experimental
BASIC STUDIES streams experimental reaeration
C-1
C-2
C-3
C-4
C-5
c Cable, M DISSOLVING OF STATIONARY GAS BUBBLES IN LIQUID Chern Eng Sci v 22 n 11 Nov 1967 p 1393-1398
Theoretical interpretation of dissolving of gas bubbles in liquids has usually been based on model which ignores effect of motion of liquid on concentration field and predicts linear relation between square of size and time; experimental data plotted in this way often show decrease in slope; theoretical results are now available which take radial motion of liquid into account; these show that decrease in slope is in accordance with theory; some experimental results are in good agreement with theory, but others show marked deviations; possible reasons for these deviations are discussed. 22 refs (EI 1968)
Cadwallader, E Thomas McDonnell, J Archie A MULTIVARIATE ANALYSIS OF REAERATION DATA Water Research Pergamon Press v 3 1969 p 731-742
Describes the application of the statistical technique of multivariate analysis to two sets of prototype reaeration data and one set of laboratory data, and to a combined set. The exchange coefficient was found to be consistently defined by the rate o{energy dissipation (E) for values of E > 0.001 ft2/sec3. For E < 0.001 factors related~ to molecular diffusion are controlling
Camp, Thomas R FIELD ESTIMATES OF OXYGEN BALANCE PARAMETERS Proc ASCE v 91 n SA 5 Oct 1965 p 1-17
Field studies of oxygen balance in Merrimack River, Mass; Streeter-Phelps equations, extended to include addition of BOD from bottom deposits, removal of BOD by settling, production of dissolved oxygen by photosynthesis, and longitudinal mixing by tides, indicated 50 to 80 percent of BOD by settling and approximately two-thirds of oxygen furnished by algae in photosynthesis; atmospheric reaeration rate constant was found to be considerably less than expected; algae was found to be essential to pollution control
Carver, C E Jr ABSORPTION OF OXYGEN IN BUBBLE AERATION Biological Treatment of Sewage and lnd Wastes v 1 1955
Carver, C E Jr OXYGEN TRANSFER FROM FALLING WATER DROPLETS Proc ASCE v 95 n SA 2 Apr 1969 p 239-251
Overall oxygen transfer coefficients are obtained for deaerated water droplets falling freely through the atmosphere with and without 50 ppm of a synthetic detergent. Drop distances ranged from 0 to 13 ft, and droplet surface areas varied from 0.47 to 0.55 cm2. Transfer coefficients are found to decrease somewhat with increasing droplet size, becoming independent of droplet size above 6.0 ppm of DO. With detergent present, the coefficients are reduced approximately 50 percent. Experiments were also performed with fully aerated water droplets falling freely through a nitrogen atmosphere. For this case, droplet surface area ranged from 0.15 to 0.50 cm2. Transfer coefficients are found to increase with increasing droplet size. Although no direct comparison of droplet sizes could be made, it is concluded that the rate of oxygen transfer for both inward and outward transfer from a droplet is not substantially different
46
BASIC STUDIES bubbles theoretica I experimental reaeration
BASIC STUDIES streams experimental reaeration
BASIC STUDIES streams experimental reaeration photosynthesis
EQUIPMENT waste treatment diffusers
BASIC STUDIES experimental reaeration
C-~
C-7
C-1:0
C-11
C-12
C-Continued
Chasick, A H Bootes, R L DETERMINING THE EFFICIENCY OF AIR FILTERS Water Works and Wastes Eng v 1 n 1 1965 p 50
Chernykh, E M 0 NEUSTOICHIVOSTI SFERICHESKOGO GAZOVOGO
PUZYRAYA V POLE PEREMENNOGO DAVLENIYA Akademiya Nauk lzvestiya Mekhanika Zhidkosti i Gaza n 1 Jan-Feb 1967
p 38-42 Instability of spherical gas bubble in variable pressure field; stability of radial motion of bubble boundary in incompressible nonviscous liquid is investigated for case of variable external pressure; possibility of steady motion existence is investigated for case of monotonic and periodic time functions of external pressure; it is proved that stability is only possible for infinitely large radii of bubble, or under very particular assumptions regarding initial conditions and pressure variations. In Russian (E I 1967)
Churchill, M A EFFECT OF DENSITY CURRENTS UPON RAW WATER QUALITY
J American Water Works Assoc v 39 n 4 194 7 p 357-360
Churchill, M A Buckingham, R A STATISTICAL METHOD FOR ANALYSIS OF STREAM
PURIFICATION CAPACITY Sewage and lnd Wastes v 28 Apr 1956
Churchill, M A EFFECTS OF STORAGE IMPOUNDMENTS ON WATER QUALITY Proc ASCE v 83 n SA 1 Feb 1957
Discusses thermal stratification and effects on dissolved oxygen
Churchill, M A EFFECT OF WATER TEMPERATURE ON STREAM
REAERATION Proc ASCE v 87 n SA 6 1961 p 59
Churchill, M A Buckingham, R A Elmore, H L PREDICTION OF STREAM REAERATION RATES Proc ASCE v 88 n SA 4 Jul 1962 p 1-46
Results are given of many field measurements of actual rates at which river water that is low in dissolved oxygen, but free of organic pollution, absorbs oxygen from atmosphere; by using dimensional analysis and multiple-regression techniques, observed reaeration rates have been related to hydraulic properties of river c,hannels; several reaeration formulas thus developed can be used to predict accurately rate at which oxygen will be absorbed by water flowing in natural stream channels
47
EQUIPMENT waste treatment diffusers
BASIC STUDIES bubbles theoretical
BASIC STUDIES reservoirs experimental reaeration oxidation
BASIC STUDIES streams experimental reaeration
BASIC STUDIES reservoirs experimental reaeration oxidation
BASIC STUDIES streams experimental reaeration
BASIC STUDIES streams ex peri menta I reaeration
C-13
C-14
C-15
C-16
C-17
C-Continued
Churchill, M A Nicholas, W R EFFECTS OF ·IMPOUNDMENTS ON WATER QUALITY National Symposium on Quality Standards for Natural Waters Ann Arbor Mich
Paper 2P1-1 Jul 1966 Results of selected studies of the quality of water flowing through large main river reservoirs in the Tennessee Valley are discussed. Selected data on the quality of water found in certain upstream storage reservoirs-primarily Guntersville, Wheeler, and Pickwick-are also presented. A beginning is made on the difficult job of predicting concentrations of DO in water released through low-level outlets from large storage impoundments. These first attempts are discussed and given an indication of the direction in which current studies are progressing. A preliminary DO prediction .equation is given. As more data become available, the equation will be expanded to consider several pertinent water quality factors (biochemical oxygen demand, chemical oxygen demand, and nutrients) in the reservoir inflow, thus permitting more accurate predictions to be made for reservoir project design, operation, and water quality conditions
Churchill, M A Nicholas, W R EFFECTS OF IMPOUNDMENTS ON WATER QUALITY Proc ASCE v 93 n SA 6 Dec 1967 p 73-90
Changes occurring in the quality of water during its passage through Tennessee River reservoirs and during lengthy storage in tributary impoundments are observed. Seasonal variations of temperatures of water discharged from main-river impoundments are discussed. DO concentrations in the water discharged from main- river reservoirs recede during the summer months but do not reach the low concentrations observed below storage impoundments. Both total coliform and fecal coliform concentrations in main stream reservoirs increase greatly below local municipalities. In tributary storage impoundments strong thermoclines develop in early spririg, and relatively cool water, low in DO, is discharged through low- level power intakes well into or throughout the summer. Low DO concentrations are also caused by biological activity in eutrophic impoundments, inflow to which are otherwise relatively free of pollution. A multiple regression technique is used to develop an equation for predicting DO concentrations to be expected in releases from a proposed impoundment
Clair, William F Beck, John D PITTSBURG GIVES ITS WATER THE AIR Water and Waste Eng Jun 1969
Describes the Air-Aqua Turnover System installed on Pittsburg water supply reservoirs and results of aeration
Cleary, E J THE REAERATION OF RIVERS I nd Water Eng Jun 1966 p 16-21
Cleasby, J L Baumann, E R OXYGENATION EFFICIENCY OF BLADED ROTOR Water Pollution Control Federation J v 40 n 3 pt 1 Mar 1968 p 412-424
Oxygen transfer data for bladed-rotor mechanical aerator are presented and factors affecting oxygen transfer are discussed; test apparatus is examined; method used for efficiency determination is demonstrated by examples; included are results of 45 experimental runs plus comparison of diffused air
48
BASIC STUDIES reservoirs ex peri menta I reaeration oxidation
BASIC STUDIES reservoirs ex peri mental reaeration oxidation
EQUIPMENT reservoirs diffusers
EQUIPMENT streams
EQUIPMENT mechanical
aerators
C-18
C-19
C-20
C-21
C-22
C-Continued
and mechanical aeration, showing rotor studied to be more efficient than hypothetical diffuser. 18 refs (EI 1968)
Cole, R MOTION OF VAPOR BUBBLES IN SATURATED LIQUIDS A I Ch E J v 13 n 2 Mar 1967 p 403-404
Data for vapor bubbles rising through saturated liquids have been obtained experimentally for variety of liquids under pressures ranging from 48 to 540 mm Hg; equivalent diameters of these bubbles ranged from 0.1 to 1.3 em and thus cover precisely region in which H. D. Mendelson's analysis should be applicable; although considerable scatter of data is evident, it is apparent that mean of data is in agreement with Mendelson's analysis. 4 refs (EI 1967)
Collins, R SIMPLE MODEL OF PLANE GAS BUBBLE IN FINITE
LIQUID J Fluid Mechanics v 22 pt 4 Aug 1965 p 761-763
Study of large gas bubbles rising in liquids has been stimulated by analogy that bubble rising in bed of solid particles fluidized by vertical flow of gas through it, appears to behave like gas bubble rising in liquid; using method due to Davies and Taylor, simple model is employed to derive velocity of two-dimensional gas bubble rising in liquid along axis of channel of finite width (EI 1966)
Committee on Sanitary Engineering Research SOLUBILITY OF ATMOSPHERIC OXYGEN IN WATER Proc ASCE v 86 n SA 4 Jul 1960
For many years the saturation concentrations of gaseous oxygen dissolved in distilled water (as determined by Fox and reported by Whipple and Whipple) have been accepted as correct. Recently a group of researchers in England conducted experiments that showed significant differences from the previously accepted saturation concentrations. The research reported herein was conducted not to determine whether the new or the old values were correct but, independently, to determine true saturation values throughout the normal range of natural stream water temperatures
Committee on Sanitary Engineering Research EFFECT OF WATER TEMPERATURE ON STREAM REAERATION Proc ASCE v 87 n SA 6 Nov 1961 p 59
A search of the literature indicated that the effect of water temperature on stream reaeration rates had not been definitely established. Extensive studies of actual stream reaeration rates required knowledge of this effect. Consequently, it was necessary to undertake experimental evaluation of the temperature coefficient, (8), of the reaeration coefficient, (k2). This was done in a series of carefully controlled, high-precision, laboratory experiments that indicate the reaeration rate increases geometrically at the rate of 2.41 percent per ° C
Committee on WATER QUALITY CR ITER lA Federal Water Pollution Control Admin Apr 1968 p 44
Includes recommendations for dissolved oxygen levels considered essential for maintaining native populations of fi:;h and other aquatic life
49
BASIC STUDIES bubbles experimental
BASIC STUDIES bubbles theoretical
BASIC STUDIES experimental reaeration
BASIC STUDIES streams experimental
GENERAL criteria
C-23
C-24
C-25
C-26
C-27
C-Continued
Conway, R A Kumke, G W FIELD TECHNIQUES FOR EVALUATING AERATORS Proc ASCE v 92 n SA 2 Apr 1966 p 21-42
Rational design and operation of an aerated biological unit requires a knowledge of the oxygen-transfer capacity of the aeration systems either under consideration or installed. Detailed methods are described for use by operating engineers in injecting the required performance data through tests of commercial aerators installed in full-scale basins. The essential features of oxygen-transfer theory are reviewed together with the relationships needed to adjust the test data to specified conditions. Two important test conditions, the required auxiliary measurements, and the basic oxygen-transfer measurements are enumerated. The results of full-scale tests based on oxygenation rates, gas-stream oxygen balances, sulfite-ion depletion rates, and biological oxygen-uptake rates are presented for large sparged turbine and entrainment aerators. The ASCE Committee on Sanitary Engineering Research is considering means of collecting, correlating, and publishing the results obtained by plant engineers and their consultants in using these techniques to conduct aerator tests
Coon, C PC Campbell, H DIFFUSED AERATION IN POLLUTED WATER Water and Sewage Works v 114 1967 p 461
Coulter, J B OBJECTIVES AND CRITERIA FOR WATER POLLUTION
CONTROL US Dept Health Education Welfare Symposium on Streamflow Regulation for
Quality Control Public Health Serv-i{:e Pub No 999-WP-30 Jun 1965 p 261-278
Discusses the judgment involved in establishing water quality criteria and the economic analysis of benefits in potential water uses
Courchaine, R J SIGNIFICANCE OF NITRIFICATION IN STREAM
BALANCE-EFFECTS ON THE OXYGEN BALANCE J Water Pollution Control Federation v 40 n 5 May 1968 p 835
Curtet, R Djonin, K ETUDE D'UN ECOULEMENT MIXTE AIR-EAU VERTICAL DESCENDANT -REGIMES, EVOLUTION DE LA CONCENTRATION
HouiHe Blanche v 22 n 5 1967 p 531-550 Study of flow and concentration conditions of vertical downward mixed water and air flow; emulsion formed by jet of water on impact against free water surface in vertical cylindrical duct is discussed and flow conditions are classified in terms of initial data for flow without air, stable air entrainment, and air entrainment with unstable pockets; air concentration pattern in water is measured by gamma-ray technique; mean slip velocity theory is discussed. In French (EI 1968)
50
EQUIPMENT waste treatment mechanical
aerators
EQUIPMENT waste treatment diffusers
GENERAL criteria economics
BASIC STUDIES streams experimental oxidation
BASIC STUDIES experimental reaeration
0-1
D
Dai'Man, V V Zhilyaeva INVESTIGATION OF LONGITUDINAL MIXING DURING BUBBLING IN STRAIGHT-THROUGH FLOW-TYPE REACTOR COLUMNS
Chern and Tech of Fuels and Oils {English translation of Khimiya i Teknologiya Topliv i Masel) p 12 Dec 1965 p 941-945
Study was made in steel and glass columns up to 9 m high and 4.1 to 29.6 em I D; bubblers at bottom consist of porous cermet and stainless steel plates; values of turbulent diffusion coefficient D under steady state and transient conditions were obtained using pulse and concentration shift methods; experimental plots are drawn correlating Peclet diffusion number, true mean liquid velocity, coefficient f and D with gas velocity; results agree with calculated values. 20 refs (EI 1967)
D-2 Danckwerts, P V SIGNIFICANCE OF LIQUID FILM COEFFICIENT IN
GAS ABSORPTION lnd and Eng Chern v 43 n 6 Jun 1951 p 1460
Describes extension of penetration theory with emphasis on concept of surface renewal
D-3 Davenport, W G Richardson, F D SPHERICAL CAP BUBBLES IN LOW DENSITY LIQUIDS Chern Eng Sci v 22 n 9 Sep 1967 p 1221-1235
Measurements have been made of rising velocities and shapes of spherical cap bubbles in column 15 em in diameter; liquids used were water, aqueous solutions of polyvinyl alcohol (PVA) with viscosities up to 216 centipoise and ethyl alcohol; gases were air, nitrogen, and carbon dioxide; with carbon dioxide, mass transfer coefficients were also obtained; relationships between measured quantities and properties of various liquids are considered; liquid viscosities up to 50 centipoise have no effect on either rising velocity or shape of spherical cap bubbles. 20 refs ( E I 1968)
D-4 Davis, R E Acrivos, A INFLUENCE OF SURFACTANTS ON CREEPING MOTION OF BUBBLES
Chern Eng Sci v 21 n 8 Aug 1966 p 681-685 Simple model is proposed for creeping motion of bubble contaminated with "insoluble" surface-active agent; existence of stagnant cap over rear of bubble is taken for granted and cap size and associated bubble drag are then computed theoretically, as functions of surface pressure at which contaminant film collapses; model, which employs no adjustable parameters, is consistent with experimental observations and, in particular, explains success of empirical correlation relating bubble drag to Bond number (EI 1967)
D-5 De Nevers, N BUBBLE DRIVEN FLUID CIRCULATIONS A I Ch E J v 14 n 2 Mar 1968 p 222-226
Bubble-driven fluid circulations are present in bubble columns, gas lifts, pool boiling, etc; their mechanism is shown to be quite similar to mechanism of natural conv·ection but with much larger driving forces; these circulations are stable in many baffled systems but unstable and rapidly changing in size,
51
BASIC STUDIES bubbles experimental
BASIC STUDIES theoretical reaeration
BASIC STUDIES bubbles. experimental
BASIC STUDIES bubbles experimental
BASIC STUDIES bubbles experimental
D-Continued
shape, and orientation in unbaffled systems; effect of these circulations in bubble columns is to lower holdup and vapor residence time, thus decreasing mass-transfer efficiency of column. 14 refs (EI 1968)
D-6 Derby, Ray L CHLORINATION OF DEEP RESERVOIRS FOR TASTE
AND ODOR CONTROL J American Water Works Assoc v 48 Jul 1956 p 777
Reports attempts to mix two Los Angeles reservoirs by compressed air introduced through a perforated hose; water was lifted in large quantites but fell back to the bottom because of inadequate horizontal circulation
D-7 Diachishin, A N discussion of MECHANISM OF REAERATION IN
NATURAL STREAMS by O'Connor and Dobbins Trans ASCE v 123 1958 p 672
D-8 Dietrich, K R DAS DIFFUMAT-BELUEFTUNGSSYSTEM Gesundheits-lngenteur v 87 n 9 Sep 1966 p 257-261
"Diffumat" aeration system; illustrated description of new patented system in which aeration of activated sludge is carried out by injecting compressed air in form of large bubbles at bottom of high (8 m and more) slim tanks; advantages of this system over surface absorption systems with water stirring and other air injection systems are shown in table listing oxygen transfer and electric energy consumption. In German (EI 1967)
D-9 Dijkman, H K M Vrengdenhil, C B THE EFFECT OF DISSOLVED GAS ON CAVITATION
IN HORIZONTAL PIPELINES J of Hydraulic Res v 7 n 3 1969
In a horizontal pipeline a pump failure may cause water-column separation at intermediate points of the pipeline. In this paper a mathematical description is given for the case of water containing dissolved gas. The main assumption is that the gas collects into a single cavity at the top of the pipeline. Using this model, the effect of the gas is considered by comparison with previous results for pure water. As a provisional conclusion it is found that the pressure-rise after compression of the cavity is less serious than in the case with vapor only
D-10 DiToro, D M O'Connor, D J THE DISTRIBUTION OF DISSOLVED OXYGEN IN A
STREAM WITH TIME VARYING VELOCITY Water Resources Res v 4 n 3 1968 p 639
D-11 Dobbins, William E BOD AND OXYGEN RELATIONSHIPS IN STREAMS Proc ASCE v 90 n SA 3 Jun 1964 p 53-79; closure in v 91 n SA 5 Oct 1965
p 549-555
52
EQUIPMENT diffusers reservoirs
BASIC STUDIES streams experimental reaeration
EQUIPMENT waste treatment diffusers
CAVITATION
BASIC STUDIES streams experimental reaeration
BASIC STUDIES streams experimental reaeration oxidation
D-Continued
D-12 Dobbins, W E DIFFUSION AND MIXING Boston Soc Engrs J v 52 n 2 Apr 1965 p 1 08- 128
Based on Fick's laws of diffusion, and convection, and movement of nonconservative substances analysis is made on transport of sediment in river, and river and estuary pollution; diagrams are plotted for variation of eddy diffusivity with scale, rate of absorption of oxygen at fixed point on surface, and oxygen absorption coefficients. 20 refs (EI 1966)
D-13 Dobbins, W E MECHANISM OF GAS ABSORPTION BY TURBULENT LIQUIDS Advances in Water Res Proc 1st International Conf Water Pollution Res
Pergamon Press Ltd London England v 2 1964 p 61 Develops a theoretical model for reaeration in turbulent systems. Best fit to experimental results occurs with model consisting of continuously replaced laminar liquid film. Includes good review and evaluation of previous theories. Discussions of paper are good
D-14 Dobbins, William E THE NATURE OF THE OXYGEN TRANSFER COEFFICIENT
IN AERATION SYSTEMS Part 2-1 of Biological Treatment of Sewage and I nd Wastes by McCabe and
Eckenfelder Reinhold New York NY 1956
D-15 Downing, A L Bayley, R W Boon, A G THE PERFORMANCE OF MECHANICAL AERATORS lnst Sewage Purification J Proc pt 3 1960 p 231-247
The paper compares oxygenation efficiencies for several types of surface aerators of British manufacture. Effects of temperature, immersion depth, surfactants, and foam suppressors are discussed. The performance of one type is compared with aeration at weirs. A short discussion of diffusers is included
D-16 Downing, A L Melbourne, K V Bruce, AM THE EFFECT OF CONTAMINANTS ON THE RATE OF
AERATION OF WATER J of Applied Chern v 7 1957 p 590
D-17 Downing, A L Truesdale, G A SOME FACTORS AFFECTING THE RATE OF SOLUTION
OF OXYGEN IN WATER J of Applied Chern v 5 Oct 1955 p 570
The effects of a number of factors on the rate of solution of oxygen in fresh and saline water were investigated experimentally to provide information about reaeration in a polluted estuary
D-18 Drachev,SM PROTSESSY SAMOOCHISHCHENIYA V SILNO SAGRYAZNENNYKH REKAKH S MALYM TASKHODOM (Processes of Self-Purification in Very Polluted Rivers with a Small Flow)
Vodosnabzh i santekhnika v 15 n 7 1940 In Russian
53
BASIC STUDIES streams estuaries experimental reaeration
BASIC STUDIES streams theoretical experimental reaeration
EQUIPMENT waste treatment
EQUIPMENT mechanical aerators
cascades diffusers
BASIC STUDIES experimental reaeration
BASIC STUDIES experimental reaeration
BASIC STUDIES streams reaeration
D-Continued
D-19 Dresnack, R Dobbins, W E NUMERICAL ANALYSIS OF BOD AND DO PROFILES Proc ASCE v 94 n SA 5 Oct 1968 p 789-807
The variation of Biochemical Oxygen Demand (BOD) and Dissolved Oxygen (DO) along a stretch of a polluted natural stream can be represented by two second-order partial differential equations. These equations are similar to the equation representing the conduction of heat in solids, with the exception that the stream equations contain additional lower-order terms. Analytical solutions have been obtained for many cases of the heat-conduction problem. However, the presence of the lower-order terms and the complexities of many of the boundary conditions make it impossible to obtain analytical solutions to the BOD and DO profile equations for most cases of practical interest. Furthermore, the numerical procedures which have been found to work for the solution of the heat conduction equation are not satisfactory for the BOD and DO equations because of the effects introduced by the lower-order terms. Procedures are presented for the numerical solution of the BOD and DO equations under temporally and spatially varying BOD and DO inputs. The procedures described are confined to the condition of steady, uniform stream flow
D-20 Driver, E E Krenkel, P A
D-21
THE EFFECTS OF MODIFICATIONS OF THE FLOW REGIME ON WASTE ASSIMILATIVE CAPACITY OF THE COOSA RIVER
Vanderbilt U Dept of Civil Eng Sanitary and Water Res Eng Tech Report No.5 1965 Nashville Tenn
Discusses the assimilative capacity and hydraulic characteristics of the Coosa River, Georgia, and the effects of waste discharges from the Georgia Kraft Company, Weiss Dam, and operations of Allatoona Dam on water quality. A reduction of 80 percent of the waste assimilative capacity may be directly attributed to the impoundment of Coosa River by Weiss Dam and the stratification induced by the heated discharge contributed by a steam electric generating plant
Dziallas, R Voith, J M FRANCIS TURBINES UNDER PARTIAL LOAD AND OVERLOAD Trans! from German by W 0 Wunderlich and S Vigander Tennessee Valley
Authority Nov 1966 Includes discussion of aeration for control of draft tube disturbances. Suggests that, at atmospheric pressure, an airflow corresponding to approximately 0.25 to 1 percent of the full load turbine discharge is necessary for control of the disturbances. States that larger quantities of air, under certain circumstances, may cause more serious distrubances, and in any case lead to a drop in efficiency
54
BASIC STUDIES streams theoretical reaeration oxidation
BASIC STUDIES streams experimental reservoirs reaeration
EQUIPMENT streams turbine
injection
E-1
E-2
E-3
E-4
E-5
E-6
E-7
E
Eckenfelder, W W Jr ABSORPTION OF OXYGEN FROM AIR BUBBLES IN WATER Proc ASCE v 85 n SA 4 Jul 1959
Several correlations have been developed to define the absorption of oxygen from gas bubbles in water. In most cases, these correlations have been derived from bubble cap plate9 and other low head devices. This paper develops relationships between the liquid film coefficient, KL and the Reynolds and Schmidt Numbers at liquid submergence depth up to 15 feet. Correlations are also developed relating the overall coefficient, KL a, to pertinent process variables. The correlations developed from laboratory data are extended to commercial diffusion devices
Eckenfelder, W W Jr OXYGEN TRANSFER AND AERATION Manual of Treatment Processes v 1 Environmental Sci Services Corp 1968
Discusses effect of waste characteristics on oxygen transfer, aerator types, and aeration design for application to sewage treatment problems
Eckholdt, M THE ARTIFICIAL AERATION OF RIVER WATER
ACCORDING TO R. VON WOLFF Soutsche Gewasserkundlicke Mitteilungen v 10 n 1 1966 p 1-11
Results of experiments at the Saar Hydroelectric Station at Mettlack ( 1964) In German
Edwards, R W Owens, M THE OXYGEN BALANCE OF STREAMS Ecology and the Industrial Society Oxford 1965
Edwards, R PLANTS AS OXYGENATORS IN RIVERS Water Res v 2 1968 p 243
Einstein, A INVESTIGATIONS ON THE THEORY OF THE BROWNIAN
MOVEMENT Ann Physik v 17 1905 p 549
Elder, R A Smith, M N Wunderlich, W 0 AERATION EFFICIENCY OF HOWELL-BUNGER VALVES J Water Pollution Control Federation v 41 n 4 Apr 1969 p 629-639
The effectiveness of the Howeii-Bunger valve as a device for aerating discharges from reservoirs was investigated under conditions of free discharge to a catchment area and discharge to a tailwater pool. The results showed that the aeration efficiency is related to the discharge velocity, and that thickness of jet and initial dissolved-oxygen concentration have little effect. At discharge velocities of 30ft per sec or more the valve proved a highly efficient aeration device for both types of discharge, while at lower velocities it was slightly more effective for free discharges than for confined discharges. A further series of tests is planned to investigate the aeration achieved when the valve discharges into a tunnel (WPA 1502 Aug 1969)
55
BASIC STUDIES bubbles experimental
EQUIPMENT waste treatment
EQUIPMENT streams turbine injection
BASIC STUDIES streams experimental reaeration
BASIC STUDIES streams experimental photosynthesis
BASIC STUDIES experimental
EQUIPMENT streams Howeii-Bunger
valves
E-8
E-9
E-10
E-Continued
Elmore, H L EFFECT OF WATER TEMPERATURE ON STREAM REAERATION Proc ASCE n SA 6 1961 p 59
Erickson, L E Ho, Y S Fan, L T MODELING AND OPTIMIZATION OF STEP AERATION
WASTE TREATMENT SYSTEMS Water Pollution Control Federation J v 40 1968 p 717
Several flow systems for use with step aeration process were examined under optimal operating conditions-completely mixed tanks-in-series systems, plug-flow systems, and composite of two; allocation of feed along system is desirable and method of determining optimum allocation and tank volumes for given type of step aeration is shown; mathematical model developed is based on certain simplifying assumptions and is considered only approximation of complex treatment process
Ettelt, G A ACTIVATED SLUDGE THICKENING BY DISSOLVED AIR
FLOTATION Purdue U-Eng Extension Ser 117 pt 1 1965 p 210-244
Use of dissolved air flotation process for sludge thickening at Chicago Southwest plant is described; theoretical aspects of flotation are expressed in mathematical relationships; laboratory tests on activated sludge were conducted in pressure cell; subsequent tests were performed to experimentally correlate terminal velocity of activated solids for various conditions; two proprietary dissolved air flotation pilot units of approximately 150 gpm feed rate were tested; performance of flotation unit was dependent on proper inlet design to maximize adhesion efficiency. Before 19th Industrial Waste Conference May 1964 (EI 1965)
56
BASIC STUDIES streams experimental reaeration
EQUIPMENT waste treatment
EQUIPMENT waste treatment mise uses
F-1
F-2
F-3
F-4
F-5
F-6
F-7
F-8
F
Fair, G M Geyer, J C WATER SUPPLY AND WASTE WATER DISPOSAL John Wiley and Sons Inc New York NY 1954
Falk,A EINSATZ VON KOLBENKOMPRESSOREN AUF KLAERANLAGEN Gas- u Wasserfach v 106 n 32 Aug 1965 p 903-905
Use of piston compressors in sewage treatment plants; certain aeration processes can be aided by compressed air, such as large delivery blowers with low pressure for aerobic decomposition, for delivery of sludge and its by-products where fast rotary pumps were found insufficient; compressed air has been found economical in transportation of sludge between treatment and drying plants separated by great distances and at different levels; procedure and equipment, and integration for automatic control (EI 1966)
Fish, F F Hull, C H J Peters, B J Knight, WE A STUDY OF THE EFFECTS OF A SUBMERGED WEIR
IN THE ROANOKE RAPIDS RESERVOIR UPON DOWNSTREAM WATER QUALITY
Special Report No. 1 Roanoke River Studies Compiled by Special Report Committee for Committee for Roanoke River Studies Feb 6 1958
Fischer, H B DISPERSION PREDICTIONS IN NATURAL STREAMS Proc ASCE v 94 n SA 5 1968 p 927
Fischerstrom, N C H LOW PRESSURE AERATION OF WATER AND SEWAGE Proc ASCE v 86 n SA 5 Sep 1960
Based on simplified theoretical considerations, a calculable system utilizing dispersed air at shallow depths has been developed. Elaborate tests and full-scale operation have proved that it is possible to obtain a good economy and an extremely high oxygenation capacity with this principle and perforated pipes as air distributors. Clogging of the pipes has been studied and satisfactorily eliminated
Ford, Maurice E Jr AIR INJECTION FOR CONTROL OF RESERVOIR LIMNOLOGY J American Water Works Assoc v 55 Mar 1963 p 267
Describes trials at Lake Wohlford, Calif. using compressed air to mix stratified water; lake was completely destratified after 58 hours of operation
Ford, ME Jr ARTIFICIAL CONTROL OF RESERVOIR LIMNOLOGY AND
ITS EFFECTS ON WATER QUALITY Paper presented at the Calif Section Fall Conf Santa Monica Calif Oct 25 1962
Fortescue, G E Pearson, J R A ON GAS ABSORPTION INTO A TURBULENT LIQUID Chern and Eng Sci v 22 1967 p 1163
57
(I I i
GENERAL
EQUIPMENT waste treatment
BASIC STUDIES reservoirs experimental
BASIC STUDIES streams theoretical experimental
EQUIPMENT waste treatment diffusers
EQUIPMENT reservoirs diffusers
EQUIPMENT reservoirs diffusers
BASIC STUDIES reaeration
F-9
F -Continued
Foster, J M Botts, J A Barbin, A R Vachon, R I BUBBLE TRAJECTORIES AND EQUILIBRIUM LEVELS IN VIBRATED LIQUID COLUMNS
ASME-Paper 68-FE-1 for meeting May 6-9 1968 Analysis of bubble behavior in vertically vibrated liquid column and experimental results of equilibrium level determinations are presented; analysis avoids usua'l approximation of small bubble pulsation and predicts nonharmonic volume pulsation; it can be used to predict bubble trajectories and equilibrium levels; vibrational amplitude affects bubble motion indirectly through its effect on thermodynamic behavior of bubble; experimental results compare favorably with analysis (EI 1968)
58
BASIC STUDIES bubbles theoretical experimental
G
G-1 Gai-Or,B Resnick,W MASS TRANSFER FROM GAS BUBBLES IN AGITATED
VESSEL WITH AND WITHOUT SIMULTANEOUS CHEMICAL REACTION
Chern Eng Sci v 19 n 9 Sep 1964 p 653-663 Model permits prediction of total mass transfer rates for sparingly soluble gas in gas-liquid contactor; model is based on average residence time of gas bubbles in continuous phase, and permits estimation of rate of diffusion per unit area as well as total area for diffusion; equations have been solved for range of variables and results are presented graphically (EI 1965)
G-2 Gameson, A L H Truesdale, G A Downing, A L RE-AERATION STUDIES IN A LAKELAND BECK J I nst Water Engr (Brit) v 9 1955 p 571
Develops a theoretical model for estimating reaeration in turbulent streams
G-3 Gameson, A and others SOLUBILITY DATA FOR SALT WATER J of Applied Chern v 5 1955 p 502
G-4 Gameson, A L H Truesdale, G A SOME OXYGEN STUDIES IN STREAMS J I nst of Water Eng Nov 1955
G-5 Gameson, A Truesdale, G A Varley SOME FACTORS AFFECTINS. THE AERATION OF FLOWING WATER Water and Sanitary Eng v 6 n 2 JIJI-1956 p 52
G-6 Gameson, A WEIRS AND THE AERATION OF RIVERS J lnstof Water Engrs v 11 ·n 6 Oct 1957 p 477
Measurements at a number of weirs resulted in the relationship:
r = 1 + abh/2
Where r is the ratio of upstream deficit to downstream deficit,
a = 1.25 in slightly polluted water, 1.0 in moderately polluted water, and 0.85 in sewage effluents;
b 1 for a free weir, 1.3 for a step weir, h is the height of fall in meters
G-7 Gameson, A L H Vandyke, KG Ogden, C G THE EFFECT OF TEMPERATURE ON AERATION AT WEIRS Water and Water Eng (Brit) v 62 1958 p 489
G-8 Gannon, J J RIVER AND LABORATORY BOD RATE CONSIDERATIONS Proc ASCE v 92 n SA 1 Feb 1966 p 135-161
Differences observed between laboratory bottle BOD rate, and river BOD rate, motivated investigation of river BOD conditions to develop better understanding of deoxygenation component of river oxygen balance
59
BASIC STUDIES bubbles theorectical
BASIC STUDIES streams theoretical experimental reaeration
BASIC STUDIES experimental reaeration
BASIC STUDIES streams experimental reaeration
BASIC STUDIES streams experimental reaeration
EQUIPMENT streams cascades
EQUIPMENT streams cascades
BASIC STUDIES streams experimental oxidation
G-Continued
relationship, limiting consideration, however, to effect of BOD rate; two river situations in Mich., one domestic waste problem on Clinton River below Pontiac, Mich. waste treatment plant, other industrial problem on Tittabawassee River below Dow Chemical Co. at Midland were studied. 39 refs (EI 1966)
G-9 Gannon, J J AERATION AT WASTE TREATMENT PLANT OUTFALL STRUCTURES
Water and Wastes Eng v 4 n 4 Apr 1967 p 62-65 Significance of aeration at waste treatment plant outfall structures is discussed and illustrated in terms of two situations-Pontiac, Mich., waste treatment plant, discharging its effluent into Clinton River, and Dow Chemical Co. waste treatment plant at Midland, Mich., discharging its effluent into Tittabawassee River; comparisons made between observed and predicted results, using equations developed by British workers studying aeration at weir systems, indicate good agreement for Pontiac, but indicate that predictions are about 13 to 14 percent higher than observed results for Dow. 12 refs (EI 1967)
G-1 0 Garancher, J LA PROTECTION D'UN PORT PETROLIER PAR UN
RIDEAU DE BULLES Houille Blanche v 22 n 4 1967 p 387'"390
Bubble screen protection for oil harbors is provided by submerged network of pipes discharging compressed air through row of nozzles along their top, and generating vertical bubble screens which form impenetrable barrier for any oil accidentally discharged into harbor; results obtained at several French ports are described; method can be used to protect beaches and river water intakes from pollution by oil and sewage. In French (EI 1968)
G-11 Geckler, J R Mackenthun, K M Ingram, W M GLOSSARY OF COMMONLY USED BIOLOGICAL AND
RELATED TERMS IN WATER AND WASTE WATER CONTROL
Public Health Service Cincinatti Jul 1963
G-12 Giebler, G Koppe, P METHODE SUR BESTIMMUNG DER WIRKUNG DES OZONS
BEl DER AUFBEREITUNG VON WASSER Gas- u Wasserfach v 1 06 n 8 Feb 1965 p 215-219
Method of determining effect of ozone during water treatment; method consists of treating water with gas mixture containing ozone; effect of ozone is measured by determining content of substances remaining in water after treatment; design and performance of experimental equipment and data on chemical action of ozone In German (EI 1965)
G-13 Glover, Robert E DISPERSION OF DISSOLVED OR SUSPENDED MATERIALS
IN FLOWING STREAMS US Geological Survey Prof Paper No 433-B Washington DC 1964
60
EQUIPMENT streams cascades
EQUIPMENT diffusers mise uses
GENERAL terms
BASIC STUDIES waste treatment experimental
BASIC STUDIES streams experimental
G-Continued
G;.14 Godfrey, Richard G Frederick, Bernard J DISPERSION IN NATURAL STREAMS Open-File Reports US Geological Survey Washington D C 1963
Gr 15 Gomella, C DIFFUSION DE L'OZONE DANS L'EAU Houille Blanche v 22 n 4 1967 p 439-449
Ozone diffusion in water; physical and chemical features of ozone are reviewed, also how 10 to 20 g/cu m of ozonized air is obtained industrially; oxidizing effect of ozone on chemical compounds in water is discussed; ozone distribution and decrease in its residual proportion in water by self-destruction are considered theoretically; application technique was tested on industrial scale. In French with English summary (EI 1968)
G.-16 Grace, J R Harrison, D INFLUENCE OF BUBBLE SHAPE ON RISING VELOCITIES OF LARGE BUBBLES
Chern Eng Sci v 22 n 10 Oct 1967 p 1337-1347 Equations are derived in two and three dimensions which relate rising velocity of large bubble in inviscid liquid to its size and to radius of curvature of its leading edge; elliptical-cap and ovary ellipsoidal bubbles rise faster than corresponding circular- and spherical-cap bubbles, and this has been confirmed experimentally using "two-dimensional" air bubbles in water; bubbles take up elliptical shapes if they enclose surface (e.g., rod) as they rise, and stability of bubbles under these conditions is considered; relevant to behavior of bubbles in fluidized beds. 11 refs (EI 1968)
G;-17 · Grindrod, J BRITISH RESEARCH ON AERATION AT WEIRS Water and Sewage Works v 109 1962 p 395
Contains brief descriptions of aeration at weirs and mentions aeration occurring at sewage works outfalls
G~18 Guillaume,F EVALUATING AERATION DEVICES Water Pollution Control Ontario v 107 n 1 1969 p 26
The author discusses the article on evaluation of aeration devices, by Black, S. A., (see Water Pollution Abstract v 42 n 978 1969), and queries the practicality of the extension of the test procedure which rates the aerator using tap water, for evaluating its adequacy for intended use and its suitability for a particular plant design. Modifications in the procedure are suggested (WPA 1621 Aug 1969)
G~19 Gunnerson, C G Bailey, T E OXYGEN RELATIONSHIP IN THE SACRAMENTO RIVER Proc ASCE v 89 n SA Aug 1963 p 95
A 15-month pollution survey of the Sacramento River showed the effects of agricultural, municipal, and industrial discharges into the river. Unexpected results of the investigation included the observation of nighttime increases and other anomalies in dissolved oxygen concentrations which limit both classical and modern approaches to characterizing oxygen relationships. Variations in respiration, which cannot be predicted with present knowledge, provide the best explanation of the observed anomalies. Additional study of changes in respiration rates of aquatic communities is required for predicting the response of a stream to waste discharges
61
BASIC STUDIES streams experimental
BASIC STUDIES waste treatment ex peri menta I
BASIC STUDIES bubbles theoretical experimental
EQUIPMENT streams cascades
EQUIPMENT waste treatment
BASIC STUDIES streams experimental reaeration oxidation respiration
G-Continued
G-20 Gustafson, Bengt Wistberg, Nils ACTIVATED SLUDGE PROCESS UNDER DEFINED CONDITIONS Kungl Teknisha Hogsholan (Sweden) 1964 .
G-21 Gutti, S R BEHAVIOR OF SMALL GAS BUBBLES IN ACCELERATED
LIQUID ProcASCE v 94 n HY 4 Jul 1968 p 1073-1082
Time dependent motion of small gas bubbles in liquids subjected to linear pressure gradient was studied; expression for bubble slip, was derived as function of liquid ~nd gas densities, initial velocities, and liquid velocity gradient was studied; expression for bubble slip was derived as function of liquid and gas densities, initial velocities, and liquid velocities, and approaches value of 0.9967 for highly accelerating flows. 14 refs (EI 1968)
62
EQUIPMENT waste treatment
BASIC STUDIES bubbles ex peri mental
H
H-1 Hamalainen, M PREVENTING THE DEPLETION OF OXYGEN BY CHANGING THE HYPO LIMN ION
Vesitalous v 10 n 3 1969 p 25-27 In winter the ice cover on many Finnish lakes causes oxygen depletion with adverse effects on water quality and fish. In the artificial lake Dammen, in Espoo, the problem ha·s been solved by installing a siphon spillway composed of plastic pipes and extending into the hypolimnion so that a continuous circulation of water is maintained, giving a satisfactory concentration of oxygen throughout the year. The method is cheap and can be adapted for use in many lakes, including impounded lakes where the head of water can be utilized to produce the necessary circulation and prevent oxygen depletion in the hypolimnion. Water Pollution Abstracts
H-2 Hanes, N B Irvine, R L NEW TECHNIQUES FOR MEASURING OXYGEN UPTAKE
RATES J Water Pollution Control Federation v 40 n 2 Feb 1968 p 223
H-3 Hann, R W Jr WATER QUALITY ASPECTS OF WATER RESOURCES
PLANNING Texas A&M U Oct 1968
Textbook for course in water quality management for USBR personnel
H-4 Harleman, DR F Holley, E R discussion of TURBULENT Of FFUSION AND THE
REAERATION COEFFICIENT by Krenke! and Orlob Trans ASCE v 128 II I p 327-333 1963
H-5 Harper, J F Moore, D W Pearson, J R A EFFECT OF VARIATION OF SURFACE TENSION WITH TEMPERATURE ON MOTION OF BUBBLES AND DROPS
J Fluid Mechanics v 27 pt 2 Feb 1967 p 361-366 Boundary conditions at surface of small bubble rising in liquid are examined theoretically, and it is shown by order-of-magnitude arguments, which are confirmed by detailed calculation in special case, that although surface-tension gradients must always exist around bubble, they are too small to affect motion appreciably unless surface-active substances are present. 13 refs (EI 1967)
H-6 Hart, I C NOMOGRAPHS TO CALCULATE DISSOLVED OXYGEN CONTENTS AND EXCHANGE (MASS TRANSFER) COEFFICIENTS
Water Res v 1 1967 p 391
H-7 Hays, James R MASS TRANSPORT MECHANISMS IN OPEN-CHANNEL FLOW PhD Thesis Vanderbilt U Nashville Tenn 1966
63
EQUIPMENT reservoirs m isc equipment
BASIC STUDIES experimental oxidation
GENERAL
BASIC STUDIES streams theoretical experimental reaeration
BASIC STUDIES bubbles theoretical
BASIC STUDIES experimental reaeration
BASIC STUDIES streams reaeration
H -Continued
H-8 Hazen, R GETTING MORE FOR WATER POLLUTION CONTROL DOLLAR Civil Eng (NY) v 37 n 12 Dec 1967 p 38-39
Present laws and policies that require waste water effluent treatment to be same regardless of effect on receiving water are unrealistic; reaeration of rivers can be done much more economically by reoxygenation than by dilution; cost might be $33/1,000 lb of oxygen added, compared to $250 for reservoir to supply extra water for dilution; zoning should allow waste producing industries only where adequate water is available; research money should be spent for usable information only, not to support laboratories and researchers;.halt should be called to producing volumes of statistics on needs and subsequent savings should be spent on constrlJction (EI 1968)
H-9 Hemphill, J METHOD OF WINTERKILL PREVENTION Arizona Game and Fish Dept 1954
Uses compressed air mixing of lakes to prevent ice forming and cutting off the oxygen supply
H-10 Higbie, R THE RATE OF ABSORPTION OF A PURE GAS INTO
A STILL LIQUID DURING SHORT PERIODS OF EXPOSURE
Trans American I nst of Chern Eng v 21 1935 p 365 Compares experimental rates of gas absorption with rates predicted by Lewis-Whitman film theory and penetration theory. Primarily concerned with short exposure periods in industrial absorption applications
H-11 Hinde, J Nelson REVITALIZING WATER THE NATURAL WAY paper American Water Works Assoc 89th Annual Conf San Diego Calif
May 18-22 1969 Describes the Air-Aqua system for controlled aeration of lakes and reservoirs. System releases air from a weighted valved tubing laid on the bottom of the lake; controlled bubble size produces a laminar uplift of a low-velocity nonturbulent flow which requires very little energy
H-12 Hinde Engineering Company WATER IMPOUNDMENT RESERVOIR, HIGHLAND SEWER
AND WATER AUTHORITY, HIGHLAND, PENNSYLVANIA Sales brochure Air-Aqua Case History 2602 Hinde Eng Co Highland Park Ill
Describes the Air-Aqua aeration system installed at ·Lioydell Reservoir to improve water quality; cost amounts to $1.45 per day for electricity, maintenance and amortization for the 208-million-gallon reservoir
H-13 Holley, .E R UNIFIED VIEW OF DIFFUSION AND DISPERSION Proc ASCE v 95 n HY 2 Mar 1969
Diffusion and dispersion are basically convective transport mechanisms. The method chosen for representing the convection in a mass balance equation is the determining factor in deciding whether diffusion or dispersion must be included in the conservation equation for a given flow. This principle is illustrated for molecular diffusion, turbulent diffusion, and longitudinal dispersion. In a given flow, the relative importance of diffusion or dispersion
64
GENERAL economics
EQUIPMENT reservoirs diffusers mise uses
BASIC STUDIES theoretical experimental reaeration
EQUIPMENT reservoirs diffusers
EQUIPMENT reservoirs diffusers
GENERAL terms
H-Continued
in different transport problems depends on the steepness of the concentration gradient. It is proposed that the term "diffusion" be reserved for transport that is associated primarily with time-averaged velocity fluctuations and that "dispersion" be used for transport associated primarily with the spatial average of velocity variations
H-14 Holley, E A SOME DATA ON DIFFUSION AND TURBULENCE IN
RELATION TO REAERATION Research Report No 21 Water Resources Center Univ of Illinois July 1969
Heat was used as a tracer to determine diffusion rates immediately below the free surface both in the "film" region and in the remainder of the water in a mixing vessel. The results tend to indicate that model can be used to represent the downward transport of a substance which is being absorbed at the free surface. Apparently, the diffusion coefficient in the "film" can be· either equal to or greater than the molecular coefficient depending on the amount of mixing at the free surface. Hot film anemometry was used to determine turbulence characteristics from 1 to 0.006 inch below the free surface of a laboratory open-channel flow. The energy spectra indicate no significant changes in the turbulence in this region. Thus, apparently turbulence exists right up to the free surface and in the "film" region. The amount of reliable data that was obtained was very limited.
H-15 Hooper, Frank F Ball, Robert C Tanner, Howard A
H-16
H-17
AN EXPERIMENT IN THE ARTIFICIAL CIRCULATION OF A SMALL MICHIGAN LAKE
Trans American Fisheries Soc v 82 1952 p 222 Attempts to mix a stratified body of water using a gasoline-drive centrifugal pump on shore to withdraw water from the hypolimnion and discharging it on the surface of a barge
Huckabay, H K Keller, A G AERATION ON AN INCLINED TRANSVERSELY CORRUGATED
SOLID SURFACE J Water Pollution Control Federation v 42 n 5 pt 2 May 1970
The "cascade board" aerates water by natural gravity flow down an inclined, transversely corrugated, solid surface. A study was carried out for angles of inclination of 5° to 30° from the horizontal. Flow rates of 0.02 to 0.08 mgd/ft of width (248 to 992 cu m/day/m of width), and temperatures of 83° to 108° F (28° to 42° C) were studied. Dissolved oxygen was measured by a microadaptation of the Winkler procedure. The mass transfer coefficient was correlated successfully in terms of flow rate and angle of inclination. The number of transfer units was found to be independent of flow rate and to correlate only with the angle of inclination. No optimum angle existed; however, the larger angles of inclination were more favorable to aeration
Hughmark, G A HOLDUP AND MASS TRANSFER IN BUBBLE COLUMNS lnd and Eng Chem-Process Design and Development v 6 n 2 Apr 1967 p 218-220
Correlation for gas holdup in bubble columns predicts values with average absolute deviation of about 11 percent from experimental holdups; recent correlation for mass transfer from single gas bubbles in liquids is applicable to swarm data for bubble columns; illustrative problem is solved. 9 refs (EI 1967)
65
BASIC STUDIES streams experimental reaeration
EQUIPMENT reservoirs pumps
EQUIPMENT streams cascades
BASIC STUDIES bubbles experimental
H -Continued
H-18 Huii,CHJ OXYGENATION OF BALTIMORE HARBOR BY PLANKTONIC ALGAE
J Water Pollution Control Federation v 35 May 1963 p 587-606
H-19 Huii,CHJ PHOTOSYNTHESIS .AS A FACTOR IN THE OXYGEN
BALANCE OF RESERVOIRS U S Dept Health Education Welfare Symposium on Streamflow Regulation for Quality Control Public Health Service Pub No 999-WP-30 Jun 1965 p 77-96
Describes studies on photosynthetic oxygenation in streams, estuaries and impoundments, and significance in controlling oxygen balance
H-20 Hull, C H J PHOTOSYNTHETIC OXYGENATION OF A POLLUTED ESTUARY Advances in Water Pollution Res v 3
E. A. Pearson (ed), Proc International Conf on Water Pollution Res London, England Sep 3-7 1962 Pergamon Press London England 1964 p 347-374 disc on p 391-395 Abstract in: London Conf Abstracts JWPCF v 34 Mar 1962 p 275-276
H-21 Humphrey, W H REMOVAL OF AGGRESSIVE CARBON DIOXIDE FROM POTABLE WATERS
Water and Water Eng v 68 n 822 Aug 1964 p 324-327 Removal of C02 in excess of that required to maintain CaC03/H2C03 equilibrium from water by aeration, marble, magnesite, lime, and dolomite filter methods; determination with aid of Tillmans graph, yielding aggressive C02 and probable pH values from free C02 and CaC03 concentrations; example of corrosiveness of agressive C02 on water systems (EI 1965)
H-22 Hunter, H M Potter, W J Lyons, E T PROGRESS REPORT-AN INVESTIGATION OF THE EFFECT
OF ENGINEERING STRUCTURES UPON THE DISSOLVED OXYGEN CONTENT OF STREAMS AND RESERVOIRS
USBR Denver Colo Report No CH-103 Apr 1961 Presents and discusses ( 1) analytical data obtained in pre I im inary investigations of (a) the dissolved oxygen content of streams and reservoirs on the Colorado-Big Thompson Project, and (b) chemical methods of determining the dissolved oxygen content of water samples; (2) recommendations for future investigative work in this field. Includes a bibliography with 348 references, many dealing with instrumentation and chemical analysis for determination of dissolved oxygen
H-23 Hurwitz, E Nogaj, R U Roeber, J A PERFORMANCE OF SUR FACE AERATORS UNDER WIDELY VARYING LOADINGS IN ACTIVATED SLUDGE SYSTEM
Water and Sewage Works v 112 Nov 1965 p R-209-212 214-216 218 Dixon, Ill. sewage treatment plant was used to test performance of surface aerators under several process applications of activated sludge system; performance and operating data of plant and sludge processes; empirical formulas developed from studies are summarized; plant was operated as conventional activated sludge plant at conventional loadings; contact
66
BASIC STUDIES experimental photosynthesis
BASIC STUDIES reservoirs experimental photosynthesis
BASIC STUDIES estuaries experimental photosynthesis
BASIC STUDIES experimental
BASIC STUDIES streams reservoirs experimental DO ANALYSIS instrumentation
EQUIPMENT waste treatment mechanical aerators
H-Continued
stabilization plant at conventional loadings; contact stabilization plant at extended aeration loadings; and high rate activated sludge plant (EI 1966)
H-24 Hutchinson Sherwood LIQUID Fl LM IN GAS ABSORPTION lnd and Eng Chern Jun 1937 p 836
H-25 Hutchison, G E A TREATISE ON LIMNOLOGY, VOL. I, GEOGRAPHY, PHYSICS ·AND CHEMISTRY
John Wiley and Sons Inc New York NY 1957 Discusses the formation and persistence of stratification in reservoirs
67
BASIC STUDIES theoretical experimental reaeration
GENERAL
1-1
1-2
1-3
1-4
1-5
I
I berall, A S Cardon, S Z AERATION MASS TRANSFER RELATED TO REYNOLDS
NUMBER J Applied Chern v 16 n 2 Feb 1966 p 64-72
Study of aeration rate data for streams and laboratory channels shows that aeration rate can be correlated with Reynolds number and Schmidt number by suitable dimensionless mass-transfer parameter which varies only slowly over wide range of Reynolds number; this parameter, analog to similar correlations in heat- and mass-transfer fields, has two different near-constant levels, one in low Reynolds number regime corresponding to molecular diffusivity, and another in high Reynolds number regime corresponding to eddy diffusivity (EI 1966)
I gnjatovic, L R EFFECTS OF PHOTOSYNTHESIS ON OXYGEN SATURATION J Water Pollution Control Federation v 40 n 5 May 1968 p R 151
Imhoff Grabbe Albrecht ERPROBUNG VERSCHIEDENER VERFAHREN ZUN
KUNSTLICHEN GEWASSERBELUFTUNG (Testing of Various Methods to Artificially Aerate Water)
Vom Wasser 1968 Band XXXV In German
Imhoff, K R UEBER Dl E REINIGUNGSLEISTUNG DER RUHRSTAUSEEN Gas- u Wasserfach v 106 n 46 Nov 1965 p 1264-1267
On purification capacity of impounded reservoirs of Ruhr River; 100 treatment plants of region for purifying drinking water are successfully increased by four Ruhr reservoirs paying for themselves by hydroelectric power generation; 1960 to 1964 chemical-biological laboratory tests of reservoir waters are tabulated, and results show that free-flowing river self-purification recovery distance is shortened by 3.2 to 3.7 higher purification values/river km by flowing through reservoirs. 24 refs In German (EI 1966)
Imhoff, K R OXYGEN MANAGEMENT AND ARTIFICIAL REAERATION
IN THE AREA OF BALDENEY LAKE AND THE LOWER RUHR RIVER
Das Gas- und Wasserfach 109 Jahrg ( 1968) Heft 34 Seite 936-941 (Wasser-Abwasser) in German
The Ruhr River in Germany has presented a major pollution-control problem for a long time. Although only a small river, the equivalent of sewage from over 2 million population comes through the central area near the city of Essen. In addition to very strict control of effluents by waste treatment plants, the pollution control agency, the Ruhrverband, has applied instream aeration as a supplemental means. Three aeration methods have been used-by introducing air into hydraulic turbines, by diffusers (bubbling from submerged orifices), and by mechanical aerators. Technical analysis allows an economic comparison as follows. In order to remove organic pollution of one population equivalent, at times of low flow, the cost would amount to 0.81 DM for a mechanical aerator, and 0.22 OM with the turbine aerator, as compared to 4.0 DM for expansion of the treatment plant to achieve the same result. Other figures show the diffuser as much less economic than the
68
BASIC STUDIES streams experimental reaeration
BASIC STUDIES experimental photosynthesis
EQUIPMENT
BASIC STUDIES streams reservoirs experimental reaeration
EQUIPMENT streams reservoirs diffusers mechanical
aerators turbine injection
1-6
1-7
1-8
1-9
1-10
1-11
I -Continued
mechanical aerator, though part of the extra cost is due to certain special circumstances. This result is in accord with recent American findings that instream aeration is an economical means in severe pollution situations. (Whipple-Rutgers)
lngols, R S POLLUTIONAL EFFECTS OF HYDRAULIC POWER GENERATION Sewage and lnd Wastes v 29 1957 p 292-297
Discusses positive and negative effects of impoundments on downstream water quality, including reduction of DO
lngols, R S EFFECT OF IMPOUNDMENT ON DOWNSTREAM WATER QUALITY, CATAWBA RIVER, S.C.
J American Water Works Assoc v 51 n 1 Jan 1959 p 42-46 Reports on conditions causing oxygen depletion in the hypolimnion of a reservoir and oxygen depl.etion in the Holsten River
lngols, R S SHORT TERM BOD Water and Sewage Works v 115 1968 p 258
Irwin, William H Symons, James M Robeck, Gordon G IMPOUNDMENT DESTRATIFICATION BY MECHANICAL.
PUMPING Federal Water Pollution Control Admin Cincinnati Mar 1966
Mechanical pumping was used to break up thermal stratification in four lakes in southern Ohio during the summer of 1964. The lake volumes were 98, 100, 120, and 1,260 acre-ft.· Each impoundment was thermally and chemically stratified before pumping began. The equipment was a float-mounted, axial-flow pump, 13-acre-ft-per-day capacity, driven by a gasoline engine. The pump drew water from the bottom and discharged it at the surface. Profiles of temperature, pH, and concentrations of dissolved oxygen and carbon dioxide were taken before .and after pumping. Data presented show that this method was effective in destratifying these lakes. In addition, the data show that water quality was improved by artificial destratification and that an entire impoundment could be mixed with the pump located at a single position. Some data are presented on total work requirements, but these were found to be dependent on the efficiency of the mechanical equipment and the percentage of cold water in the impoundment before pumping
Isaacs, W P ATMOSPHERIC OXYGENATION AND BIOLOGICAL
DEOXYGENATION IN AN IDEALIZED STREAM FLOW MODEL
Dissertation Abstracts v 28 n 12 1968 p 5052 Chern Abstracts v 69 1968 p 7498
Isaacs, W P Gaudy, A F Jr ATMOSPHERIC OXYGENATION IN A SIMULATED STREAM Proc ASCE v 94 n SA 2 Apr 1968 p 319-344
A simulated stream channel was used in laboratory investigations to determine a rational expression relating stream variables and fluid properties
69
BASIC STUDIES reservoirs ex peri menta I
BASIC STUDIES reservoirs experimental oxidation
BASIC STUDIES waste treatment experimental oxidation
EQUIPMENT reservoirs pumps
BASIC STUDIES streams theoretical oxidation
BASIC STUDIES streams experimental reaeration
I -Continued
which define the reaeration rate constant, K2. Direct measurement of the reaeration coefficient at controlled depths and stream velocities enabled the development of a dimensionally homogeneous expression for K2. The developed expression accounts for variations in K2 due to changes in temperature as well as changes in fluid flow conditions. For the rectangular cross section employed in these studies, the reaeration rate constant, K2, was found to be directly proportional to average stream velocity, and inversely proportional to the average stream depth raised to the 3/2 power. The constant of proportionality was found to be 3.053. When the same analytical approach was applied to the best available natural stream data, the proportionality constant obtained was 3.739. Both analyses yielded highly acceptable correlation coefficients. It is believed that the difference in the values of the proportionality constant is due primarily to differences in channel geometry, i.e., smooth rectangular laboratory channel versus irregular-shaped natural river channels
70
J-1
J-2
J-3
J-4
J-5
J
Jackson, D F EFFECTS OF ALGAE ON WATER QUALITY NY State Dept Health-Water Quality Res Symposium 1 st-Proc Feb 1964
p 2-23 Certain changes in water quality which are associated with dynamics of algae metabolism were studied; theoretical equation to evaluate phytoplankton dynamics is presented; factors of light and temperature are integrated to provide foundation for physiological process of photosynthesis; incident solar radiation, as well as compensation point of light, may be determined by means of submarine photometer; review of literature on investigations of effects and dynamics of algae. 53 refs ( El 1966)
Jackson, M L Collins, W D SCALE-UP OF VENTURI AERATOR lnd and Eng Chem-Process Design and Development v 3 n 4 Oct 1964 p 386-393
Energy losses and oxygen transfer characteristics of two sizes of Venturi devices, designed for air aspiration by liquid, were compared; in large-scale system, transfer factors for water and for very dilute sulfite solutions, corresponding to falling and constant driving force conditions, were essentially equal ( El 1965)
Jackson, R Bradney, L Bragstad, R E SHORT-TERM AERATION SOLVES ACTIVATED SLUDGE
EXPANSION PROBLEMS AT SIOUX FALLS J Water Pollution Control Federation v 37 n 2 Feb 1965 p 255-261
Operation of sewage treatment plant for treatment of waste water at Sioux Falls, S. Oak., that is complicated by high-strength industrial meat waste and receiving stream which at times measures nearly zero flow; based on pilot plant studies, full-scale short-term aeration system was designed and installed; eight aerators were installed in each of three passes of existing aeration tank; impellers used are flat-blade turbines; aeration tanks were modified to provide for cross-flow feeding; plant was designed to operate activated sludge portion according to efficiency of trickling filters (EI 1965)
Jameson, G J Kupferberg, A PRESSURE BEHIND BUBBLE ACCELERATING FROM
REST -SIMPLE THEORY AND APPLICATIONS Chern Eng Sci v 22 n 7 Jul 1967 p 1053-1055
When gas bubble is formed at point in relatively inviscid liquid, its initial motion is determined by balance between buoyancy and inertia; bubble breaks off when its base reaches gas supply point and accelerates away from source; in its wake, bubble leaves distinct pressure field; it is suggested that this pressure, whose approximate magnitude can be calculated by potential flow theory, is responsible for phenomenon of dumping or weeping on sieve trays; it may also have important effects in other situations involving accelerating bubbles such as fluidized beds and in nucleate boiling. 7 refs (EI 1968)
Jawonski, Nonhert A Weber, Walter J Deininger, Roolf A OPTIMAL RELEASE SEQUENCES FOR WATER QUALITY
CONTROL IN MULTIPLE-RESERVOIR SYSTEMS Michigan U (sets T-68-1) Apr 1968
71
BASIC STUDIES theoretical photosynthesis
EQUIPMENT Venturis
EQUIPMENT waste treatment mechanical aerators
BASIC STUDIES bubbles theoretical
GENERAL
J-6
J-7
J-8
J-9
J-10
J -Continued
Jayne, T D Sedlacek, R J DEVELOPMENT AND CONSTRUCTION OF AN INSTRUMENT
FOR MEASUREMENT OF STREAM AERATION RATE Public Health Service Contract No. PH-86-64-14 Rand Development Corp Cleveland
1964
Jenks, J H HIGH-RATE PONDING SYSTEM SOLVES SEASONAL HIGH
LOAD PROBLEM FOR HAYWARD, CALIFORNIA Water and Waste Eng v 3 n 11 Nov 1966 p 50-53
Feature of program of waste water treatment and disposal is use of high-rate recirculation and aeration pending system; to meet initial treatment needs for 19 mgd of combined sanitary sewage and seasonal high-strength wastes associated with local food processing industry; single "lnka" grid installed in high-rate pond was operated at submergence of 28 in.; air was generally supplied to grid at rate of 500 cfm; at that rate, blower power requipment was 5 hp; full-scale ponds are divided into four separate units, each with its own recirculation and aeration system ( El 1967)
Johnson, A I Besik, F Hamielec, A E MASS TRANSFER FROM A SINGLE RISING BUBBLE Canadian J of Chern Eng v 47 n 6 Dec 1969 p 559
Describes water column experiments to determine bubble sizes and transfer rates of carbon dioxide, ethylene, and butene. Results are compared with previous investigations and an empirical equation is presented
Johnson, V E Jr CAVITATION IN HYDRAULIC STRUCTURES: MECHANICS OF CAVITATION
Proc ASCE v 89 n HY 3 May 1963 p 251-275 A summary review of the knowledge related to the mechanism of cavitation is presented. Stability criteria for a spherical gas nucleus as well as the possible origins of such nuclei are examined. The critical pressure for cavity instability depends on the type and size of nuclei present in the flow. This critical pressure in large hydraulic structures ma'y usually be taken as the liquid vapor pressure, but for small models tested in laboratory facilities, the critical pressure can be much less than vapor pressure. For streamlined bodies with unseparated boundary layers, the conditions for cavitation inception may be predicted by setting the minimum boundary pressure equal to the critical pressure. This method is usually inadequate for the case of bodies with separated flows; however, a method of conservatively estimating the conditions for cavitation inception in separated flows is presented. The dynamics of a collapsing cavity are examined, and the influence of the boundary layer on the types of cavities formed and the resulting damage is also reviewed. The "scale effects" suggested by the mechanics of the cavitation process are presented
Juliano, David W REAERATION MEASUREMENTS IN AN ESTUARY Proc ASCE v 95 n SA 6 Dec 1969 p 1165-1178
Measurements of surface reaeration are presented for the Sacramento-San Joaquin Delta. Estimates of reaeration were computed from observed diurnal dissolved oxygen changes in the estuary. The reaeration constants computed in this manner varied between 0.16 and 3.91 grams per cu m per hr at
72
DO ANALYSIS instrumentation
EQUIPMENT waste treatment diffusers
BASIC STUDIES bubbles experimental
CAVITATION
BASIC STUDIES estuaries experimental
J -Continued
0-percent saturation. Independent in situ measurements using gasometric and disturbed equilibrium methods were conducted for comparison. Reaeration constants varied from 0.64 to 2.84 gm per cu m per hr using the gasometric method. The disturb~ equilibrium method yielded reaeration constants between 0.62 and 1.70 gm per cu m per hr. The independent methods showed reaeration constants to be highly variable. Surface turbulence proved to be the most important mechanism controlling reaeration constants in the estuary. Wind velocity was the singularly most significant parameter in causing surface turbulence
73
K-1
K-2
K-3
K
Kalinske, A A ECONOMIC EVALUATION OF AERATOR SYSTEMS Environmental Sci Tech v 3 1969 p 229-234
In an illustrated article the author discusses the principles of design and operation of aerators and aeration systems, and describes methods for evaluating performance. (Water Pollution Abstracts)
Kalinske, A A EVALUATION OF OXYGENATION CAPACITY OF
LOCALIZED AERATORS J Water Pollution Control Federation v 37 n 11 Nov 1965 p 1521-1529
TheorP.tical bases for techniques used to evaluate performance of aeration equipment are indicated, and conditions and limitations specified; it is shown that general theory that was developed for absorption of oxygen from air bubbles diffused into aeration basins is based on uniform conditions throughout any liquid volume under consideration; such conditions are not always obtained with localized aerators; therefore, relationships developed for uniform conditions must be used with care (EI 1966)
Kalinske, A A SURFACE "AERATORS" FOR ABSORPTION AND
DESORPTION OF GASES INTO WATER AND LIQUID WASTES
Water and Sewage Works v 115 n 1 Jan 1968 p 33-37 Problem of supplying oxygen and removal of carbon dioxide or hydrogen sulfide from water and waste water is discussed and several solutions are detailed; methods for calculation of necessary size of surface aerators, and retention times; aeration of flowing stream and removal of C02 from fixed volume of liquid and from flowing liquid (EI 1968)
K-4 Kalinske, A A Shell, G L Lash, L D HYDRAULICS OF MECHANICAL SURFACE AERATORS Water and Wastes Eng v 5 n 4 1968 p 65
K-5 Kalman, L ELECTROCHEMICAL MEASUREMENT OF THE OXYGEN CONTENT IN WATER, WASTE WATER, AND SLUDGE
Schweiz Z Hydrol v 31 n 1 1969 p 141-149 A newly developed apparatus for measuring oxygen concentrations is described. The apparatus works without any membrane, and no maintenance and readjustment is necessary even if it is used in activated sludge. The readings are only slightly affected by salt concentrations and pH of the medium. Practical experience with the use of the apparatus at the Horgen sewage treatment plant is reported. The application of the apparatus for continuous control of oxygen transfer in aeration basins by using different aeration systems is mentioned
K-6 Kaplovsky, A J Walters, W R Sosewitz, B ARTIFICIAL AERATION OF CANALS IN CHICAGO J Water Pollution Control Federation v 36 n 4 Apr 1964 p 463
74
EQUIPMENT economics
EQUIPMENT waste treatment diffusers
EQUIPMENT streams waste treatment mechanical
aeratorS:
EQUIPMENT mechanical aerators,
DO ANALYSIS instrumentation
EQUIPMENT streams
K-Continued
K-7 Kaplovsky, A Joel discussion of CHANGES IN WASTE ASSIMILATION
CAPACITY RESULTING FROM STREAMFLOW REGULATION by R. A. Vanderhoof
US Dept Health Education Welfare Symposium on Streamflow Regulation for Quality Control Public Health Service Pub No 999-WP-30 Jun 1965 p 146-151
Gives a concise definition of assimilative capacity and questions the generally accepted concept that increased flow improves water quality; the important question is whether the loss of stabilization time within a given estuarine segment is sufficiently compensated by the lower concentration buildup level induced by an increase in flow
K-8 Kehr, Robert W MEASURE OF NATURAL OXIDATION IN POLLUTED
STREAMS. IV. Effect of Sewage on Atmospheric Reaeration Rates under Flow Conditions
Sewage Works J v 1 0 n 2 1938 p 228-240
K-9 Kerri, K D A DYNAMIC MODEL FOR WATER QUALITY CONTROL J Water Pollution Control Federation v 39 n 5 May 1967 p 772
K-10 King, D L HYDRAULICS OF STRATIFIED FLOW-SECOND PROGRESS
REPORT -SELECTIVE WITHDRAWAL FROM RESERVOIRS USB R Denver Colo Report No Hyd-595 Sep 1969
K-11 King, H R DESIGN OF AIR DISTRIBUTION SYSTEMS FOR ACTIVATED SLUDGE PLANTS
Water Works and Sewage v 91 1944
K-12 King, Henry R MECHANICS OF OXYGEN ABSORPTION IN SPIRAL
FLOW AERATION TANKS, EXPERIMENTAL WORK Sewage and lnd Wastes v 27 n 9 1955 p 1007-1026
K-13 Kishinevski, M TWO APPROACHES TO THE THEORETICAL ASPECTS
OF GAS ABSORPTION J of Applied Chern USSR Sep 1955 p 881 In Russian
K-14 Kitrell, F W EFFECTS OF IMPOUNDMENTS ON DISSOLVED OXYGEN
RESOURCES Sewage and I nd Wastes v 31 n 9 Sep 1959 p 1065-1078
Discusses the formation and persistence of stratification in reservoirs. Discusses stratification in impounded water, effects on dissolved oxygen, and theoretical energy requirements for mixing stratified reservoirs 1 to 25 kwhr/ac of surface per year. 30,000 acres, 1,500,000 acre-ft $5,850/yr
75
BASIC STUDIES streams
BASIC STUDIES streams experimental reaeration oxidation
GENERAL
BASIC STUDIES reservoirs theoretical experimental
EQUIPMENT waste treatment
EQUIPMENT waste treatment diffusers
BASIC STUDIES theoretical reaeration
BASIC STUDIES reservoirs theoretical
K-Continued
K-15 Kitrell, F W THERMAL STRATIFICATION IN RESERVOIRS US Dept Health Education Welfare Symposium on Streamflow Regulation for
Quality Control Public· Health Service Pub No 999-WP-30 Jun 1965 p 57-76
Discusses temperature stratification in reservoirs, patterns of summer and winter stratification, and current tilted thermoclines
K-16 Kleijn,HFW OXYGEN DEMAND NUMBER.....:NEW TOOL IN ESTIMATION OF OXYGEN DEMAND OF INDUSTRIAL AND DOMESTIC WASTE WATER
Air and Water Pollution v 10 n 8 Aug 1966 p 521-535 New system is evolved for calculation of theoretical oxygen demand that is particularly suited for evaluation of industrial waste water, but is valid as well in judgment of domestic waste and polluted water; amount of organic substances and in general oxidizable substances is expressed in carbon g-equivalent, which are so defined that elements nitrogen, sulfur, and phosphorus are equivalent with carbon; oxygen demand number of substance is number of g-equivalent oxygen needed for complete oxidation of one carbon g-equivalent of substance; this is derived from elemental composition. 24 refs (EI-1967)
K-17 Knight, W E IMPROVEMENT OF THE QUALITY OF RESERVOIR
DISCHARGES THROUGH CONTROL OF DISCHARGE ELEVATION
U S Dept Health Education Welfare Symposium on Streamflow Regulation for Quality Control Public Health Service Pub No 999-WP-30 Jun 1965 p 279-298
Discusses the concentration of dissolved oxygen in water discharged from a reservoir and selective level withdrawals from John H. Kerr Dam, Gaston Dam, and Roanoke Rapids Dam on the Roanoke River
K-18 Koberg, G E ELIMINATION OF THERMAL STRATIFICATION BY AIR-BUBBLING TECHNIQUE IN LAKE WOHLFORD, CALIFORNIA
US Geological Survey-Professional Paper 501-D 1964 p 190-192 Use of experimental air-bubbling system at Lake Wohlford, Calif., resulted in elimination of thermal stratification, definite improvement in taste and odor of water, and net reduction in evaporation of 35 acre-ft (5 percent) in 1962 (EI-1962)
K-19 Koberg, G E Ford, ME Jr ELIMINATION OF THERMAL STRATIFICATION IN
RESERVOIRS AND THE RESULTING BENEFITS Geological Survey Water-Supply Paper 1809-M 1965
The use of air bubbling to artificially induce mixing in a lake has been successful 'in_several investigations reported in the literature. A detailed study of this technique in Lake Wohlford in collaboration with the EscondidO Mutual Water Co. of Escondido, Calif., is presented.
76
BASIC STUDIES reservoirs
BASIC STUDIES waste treatment theoretical experimental .. oxidation
BASIC STUDIES reservoirs experimental
EQUIPMENT reservoirs diffusers
EQUIPMENT reservoirs diffusers
K-20
K-21
K-~2
K-23
K-Continued
The results of the Lake Wohlford study indicate that the air-bubbling system is economically feasible to remove undesirable taste and odors from the water used for domestic purposes and to increase the dissolved-oxygen concentration in the hypolimnion of the lake. The results also indicate that the elimination of thermal stratification can reduce evaporation. The elimination of thermal stratification in Lake Wohlford during May, June, and July reduced the evaporation 15 percent. Although the evaporation was increased ·9 percent in September, October, and November, the net reduction for the 6 months was about 6 percent.
The Lake Wohlford study and other tests cited have not presented enough data to define criteria for design of an air-bubbling system for a thermally stratified reservoir of a given capacity. Further studies are needed on larger reservoirs before design criteria can be established
Kolbe, F F ARTIFICIAL OXYGEN REGENERATION AT GOREANGA8 DAM The Civil Engr of So Africa v 6 1964
Reports on use of air bubble gun to mix a reservoir to increase oxygen content
Kothandaraman, V Ewing, 8 8 A PROBABILISTIC ANALYSIS OF DISSOLVED OXYGEN
BIOCHEMICAL OXYGEN DEMAND RELATIONSHIP IN STREAMS
J Water Pollution Control Federation v 41 1969 p R73-R90 Statistical analysis of the relation between dissolved oxygen and BOD in streams has shown that variations in the values of the deoxygenation and reaeration coefficients have a significant effect on the prediction of dissolved-oxygen level in polluted streams, and the error caused by the variations in these coefficients increases with increase in temperature. The most probable value for the oxygen deficit predicted by the probabilistic model using the Monte Carlo simulation techniques was found to be a better estimate than the values predicted by the conventional deterministic methods
Krenke!, P A TURBULENT DIFFUSION AND THE KINETICS OF
OXYGEN ABSORPTION PhD Thesis U of Calif 1960
Krenkel, Peter A Orlob, Gerald T TURBULENT DIFFUSION AND THE REAERATION
COEFFICIENT Proc ASCE v 88 n SA 2 Mar 1962 p 53-83
Reports on study of oxygen absorption as related to concepts of turbulent flow, explanation of mechanism causing transfer of oxygen into water, and development of a practical method of estimating oxygen transfer rates in open channel flow using easily obtained hydraulic parameters. Experimental reaeration coefficient and longitudinal mixing coefficient show a direct correlation between parameters when depth of flow is taken as a measure of eddy size. Transfer of oxygen mclecules into a liquid is explained by the kinetic gas theory assuming only oxygen molecules with sufficient activation energy would be absorbed by the liquid
77
EQUIPMENT reservoirs hydraulic guns
BASIC STUDIES streams experimental reaeration oxidation
BASIC STUDIES streams theoretical experimental reaeration
BASIC STUDIES streams theoretical experimental reaeration
K~Continued
K-24 Krenke!, P A Williams, H E discussion to PREDICTION OF STREAM REAERATION
RATES by M.A. Churchill Proc ASCE J Sanitary Eng Div Apr 1963
K-25 Krenke!, Peter A Cawley, William A Minch, Virgil A THE EFFECT OF IMPOUNDING RESERVOIRS ON RIVER WASTE ASSIMILATIVE CAPACITY
J Water Pollution Control Federation Sep 1965 p 1203-1217 Reduction of the waste assimilative capacity of reservoirs is mainly caused by inherent low DO in reservoirs, peaking power operations, and stratified flow conditions induced by cooling water discharge from a steam electrical generating plant. Studies were conducted on Coosa River, Ga. at the Georgia Kraft Mill, Mayos Bar, Weiss Reservoir, and Allatoona Reservoir
K-26 Krenke!, P A Thackston, E L Parker, F L THE INFLUENCE OF IMPOUNDMENTS ON WASTE
ASSIMILATIVE CAPACITY Proc of the Speciality Conf on Current Res into the Effects of Reservoirs on Water Quality ASCE Portland Oreg Jan 1968
K-27 Krishnamurthi, S Kumar, R Kuloor, N R FORMATION OF BUBBLES Chern and Process Eng v 49 n 1 Jan 1968 p 91-97, 1 00
Many operations, particularly distillation, require knowledge of sizes of bubbles; classical studies and models of bubble formation under constant flow conditions are examined, and new model is developed from empirical considerations, showing bubble volume (EI 1968)
78
BASIC STUDIES streams experimental reaeration
BASIC STUDIES reservoirs experimental
BASIC STUDIES reservoirs streams theoretical experimental reaeration
BASIC STUDIES bubbles experimental
L-1
L-2
L-3
L-4
L-5
L-6
L
Lackey, Robert T EFFECTS OF ARTIFICIAL DESTRATIFICATION ON
PARVIN LAKE, COLORADO Progress Report Project F-46-R-1 Colorado State University May 1970
Reports use of "Helixor" device for: destratification of small lake to prevent winterkill of fish
Lamb, M discussion of MECHANISM OF GAS ABSORPTION BY
TURBULENT LIQUIDS by W. E. Dobbins Proc 1st International Conf Water Pollution Res Pergamon Press Ltd London
England v 2 1964 p 78 Contains description of transfer from bubbles originating from porous or nozzle diffusers. Shows efficiency advantage of porous type over nozzle type. Describes full-scale laboratory tests in which diffuser locations were varied
Langbein, W B Durum, W H THE AERATION CAPACITY OF STREAMS US Geological Survey Circular No. 542 1967
Examines the variations in the coefficient of reaeration due to velocity, depth, and discharge of rivers; computations are made for the tons of oxygen per day that could be absorbed by the river for each unit of oxygen less than the saturation value
Landberg, G G Graulich, B P Kipple, W H EXPERIMENTAL PROBLEMS ASSOCIATED WITH THE TESTING OF SURFACE AERATION EQUIPMENT
Water Res v 3 n 6 Jun 1969 The method of testing surface aerators by unsteady-state reaeration of water at low or zero oxygen concentration is discussed and the assumptions made in applying the usual differential equation to calculate the mass-transfer coefficient are queried. Possible errors caused by the use of added chemicals to reduce the oxygen level, the existence of microscopically entrained gas bubbles, and the transport of gas bubbles to regions of significant hydrostatic pressures in deep tanks are pointed out. Test data obtained in various environmental conditions are described and discussed in relation to published work
Laughlin, J E STUDIES IN FORCE MAIN AERATION Proc ASCE v 90 n SA 6 Dec 1964 p 13-24
Studies of an existing system showed air injection into a force main was an effective, economical, and reliable measure for controlling sulfides generation. Additional benefits included some degree of BOD reduction and removaJ of friction-producing bacterial filaments. Air at the force main outlet was not odorous, and contained only trace amounts of hydrogen sulfide. Generation of sulfides returned to normal levels a few days after aeration ceased. Analytical techniques used may apply elsewhere. The design rationale may be of value in other installations in which general conditions are similar
Leach, L E Duffer, W R Harlin, C C Jr PILOT STUDY OF DYNAMICS OF RESERVOIR
DESTRATI FICATION RobertS. Kerr Water Res Center Ada Okla 1968
79
EQUIPMENT reservoirs diffusers
EQUIPMENT diffusers
BASIC STUDIES streams experimental reaeration
EQUIPMENT mechanical aerators
EQUIPMENT waste treatment ~isc equipment
BASIC STUDIES reservoirs experimental
L-7
L-8
L-9
L-10
L-11
L-12
L-13
L-Continued
Leary, R D Ernest, LA Katz, W J EFFECT OF OXYGEN TRANSFER CAPABILITIES AND WASTE WATER TREATMENT PLANT PERFORMANCE
J Water Pollution Control Federation v 40 n 7 Jul 1968 p 1298-1310 Performance of Jones Island Waste Water Treatment Plants, Milwaukee, Wis., were reduced because of inadequate oxygen transfer capabilities at one plant and because of introduction of poor waste-activated sludge from the plant into another plant. The spiral-flow aeration basin gave the lowest oxygen transfer of seven patterns tested; the ridge-and-furrow placement was the most efficient oxygen diffuser system
Le Bosquet, M Jr discussion of THE OXYGEN SAG AND DO RELATIONSHIPS
IN STREAMS by H. W. Streeter Oxygen Relationships in Streams Tech Report W58-2 Robert A Taft Sanitary Eng
Eng Center US Public Health Service
Lee, W S discussion of IMPROVEMENT OF THE QUALITY OF
RESERVOIR DISCHARGES THROUGH TURBINE OR TAILRACE AERATION
US Dept Health Education Welfare Symposium on Streamflow Regulation for Quality Control Public Health Service Pub No 999-WP-30 Jun 1965 p 308-312
Cites aeration experiments with Francis turbines at the Wylie Station plant on the Catawba River, S. C.; reaeration effectiveness depends upon the turbine characteristics, load being carried, the setting of the wheel above tailwater elevation, vacuum-breaker arrangement, and the shape and dimensions of the draft tube
Lemke, A A FLOW OF AIR IN PIPES Sewage and I nd Wastes v 24 1952 p 24
Lewis Whitman PRINCIPLES OF GAS ABSORPTION lnd Eng Chern v 16 1924 p 1215-1220
Describes film theory of mass transfer
Li, P S West, F B Vance, W H Moulton, R W UNSTEADY STATE MASS TRANSFER FROM GAS
BUBBLES-LIQUID PHASE RESISTANCE A I Ch E J v 11 n 4 Jul 1965 p 581-587
Theoretical basis for mass transfer from gas bubbles is important for predicting distillation and absorption efficiencies; liquid-phase, mass-transfer coefficients were determined for streams of bubbles in water, gases used were pure oxygen, 10 percent carbon dioxide in air, and 10 percent chlorine in air. 31 refs (EI 1965) .
Li, W H UNSTEADY DISSOLVED-OXYGEN SAG IN STREAM Proc ASCE v 88 n SA 3 May 1962 p 75-85
Solution is obtained for distribution of dissolved oxygen in polluted water of stream in which volume and velocity of flow are steady at any cross section,
80
EQUIPMENT waste treatment diffusers
BASIC STUDIES streams experimental reaeration oxidation
EQUIPMENT streams turbine injection
EQUIPMENT
BASIC STUDIES theoretical reaeration
BASIC STUDIES bubbles theoretical experimental
BASIC STUDIES streams theoretical reaeration
L-14
L-15
L-16
L-17
L-18
L-19
L-Continued
but not necessarily uniform at all cross sections; solu~ion can account for added discharge and pollution along course of streams; in addition, unsteady distribution of dissolved oxygen due to unsteady initial oxygen content and BOD I oad can be computed ( E I 1962)
Liebman, J C Lynn, W R THE OPTIMAL ALLOCATION OF STREAM DISSOLVED
OXYGEN Water Resources Res v 2 1966 p 581 Chern Abstracts v 66 · 1967 p 1359
Lin, T J Donnelly, H G GAS BUBBLE ENTRAINMENT BY PLUNGING LAMINAR
LIQUID JETS A I Ch E J v 12 n 3 May 1966 p 563-571 ·
Investigation of factors affecting air entrainment process of free, liquid jet plunging into pool of same liquid; entrainment only occurs when average jet velocity exceeds certain value called minimum entrainment velocity; correlation of Weber numbers and Reynolds numbers which permits prediction of minimum entrainment velocity was developed; relevant to pouring of molten glass or polymer solutions, and paint, food, detergent, cosmetics, and pharmaceutical industries. 14 refs (EI 1966)
Londong, D FLUBWASSERBELUFTUNGEN AN DER LIPPE (River Water Aeration on the Lippe)
Gewasserschutz-Wasser-Abwasser Band 1 Aachen 1968
Loucks, D P Lynn, W R PROBABILISTIC MODELS FOR PREDICTING STREAM QUALITY Water Resources Res v 2 1966 p 593 Chern Abstracts v 66 1967 p 1359
Loucks, D P Revelle, C S Lynn, W R LINEAR PROGRAMMING MODELS FOR WATER POLLUTION CONTROL
Management Sci v 14 n 4 Dec 1967 p B -166-81 Two linear programming models are presented for determining amount of waste water treatment required to achieve at minimum cost any particular set of stream dissolved oxygen standards within river basin; derived from generalized Streeter-Phelps differential equations used to describe rates of dissolved oxygen depletion and recovery of streams, these models are adaptable to any river basin configuration; they can be used not only in determining system costs for various quality standards but also for measuring cost sensitivity to changes in stream and waste-water flows and treatment facility location; example illustrates use of these models (EI 1968)
Love, S K RELATIONSHIP OF IMPOUNDMENT TO WATER QUALITY J American Water Works Assoc v 53 n 5 May 1961 p 559-568
Describes oxygen depletion conditions in the hypolimnion of a reservoir
81
BASIC STUDIES streams
EQUIPMENT cascades
EQUIPMENT streams
BASIC STUDIES streams theoretical
BASIC STUDIES streams theoretical reaeration oxidation
BASIC STUDIES reservoirs experimental oxidation
L-20
L-21
L-Continued
Love, S K Slack, K V CONTROLS ON SOLUTION AND PRECIPITATION IN
RESERVOIRS US Dept Health Education Welfare Symposium on Streamflow Regulation for
Quality Control Public Health Service Pub No 999-WP-30 Jun 1965 p 97-128
Examines the environmental events bringing about encounters with water and new solid phases or between unlike water masses in reservoirs with a detailed discussion of the resulting chemical reactions
Lueck, B F Wiley, A J Scott, R H Wisniewski, T F DETERMINATION OF STREAM PURIFICATION CAPACITY Sewage and I nd Waste v 29 Sept 1957 p 1 054
82
BASIC STUDIES reservoirs
BASIC STUDIES streams experimental reaeration
M-1
M
Mackenthun, K M THE EFFECTS OF NUTRIENTS ON PHOTOSYNTHETIC
OXYGEN PRODUCTION IN LAKES AND RESERVOIRS US Dept Health Education Welfare Symposium on Streamflow Regulation for
Quality Control Public Health Service Pub No 999-WP-30 Jun 1965 p 205-220
Biological activity influences chemical parameters including dissolved oxygen; it is governed by temperature and stimulated by nutrients
M-2 Malz, F Bischofsberger UEBER DIE ANWENDUNG POROESER PASTIKMATERIALI EN
ALS BELUEFTUNGSKOERPER IN BELEBUNGSANLAGEN Gas- u Wasserfach v 102 n 44 Nov 1961 p 1197-1199
Use of porous plastic materials as aerators in activated sludge tanks; efficiency of porous polyvinylchloride or polyester foil in aeration of sewage water; data on loss of pressure depending on velocity of airflow; data on amount of introduced oxygen; plastic aerators can be easily cleaned; this is advantage as compared to ceramic aerators In German (EI 1962)
M-3 Maney, K H Okun, D A EFFECTS OF SURFACE ACTIVE AGENTS ON AERATION Water Pollution Control Federation J v 37 n 2 Feb 1965 p 212-227
Study was conducted to analyze theoretically and experimentally effect of surface active agents (SAA) on oxygen transfer kinetics; effect of SAA on oxygen transfer from air to water was studied in aeration vessels of different geometry in which water ~s stirred at various speeds; gas transfer was postulated as encountering total resistance composed of sum of two main resistances in series, liquid surface resistance and liquid bulk resistance; resistance to gas transfer was defined as being equal to reciprocal of rate constant. 36 refs ( El 1965)
M-4 Manczak, H VERBESSERUNG DER SAUERSTOFFVERHALTNISSE EINES
GEBIRGSBACHES MITTELS SOHLENABSTAFFELUNG (Improving the Oxygen Content of a Mountain Stream by Means of Steps in the Bed) Osterreichische Wasserwirtschaft 1964 Heft 9/10 In German
M-5 Manzack, H THE COURSE OF SELF-PURIFICATION PROCESS OF
CANALIZED HIGHLY POLLUTED RIVERS Water Res v 2 n 1 Jan 1968 p 3-4
A study to establish the capacity of self-purification in channeled and unchanneled sections of Odra River, Poland is described. Hydrographic, hydrometric, chemical, and biological measurements in the river showed: ( 1) ice cover reduced the biochemical processes; (2) the coefficient of oxygen utilization in polluted water was about half that from unpolluted water; (3) this coefficient decreased sharply during the navigable period; (4) the reaeration process was much lower in channeled section of the river than in unchanneled sections; (5) the self-purification capacity was relatively high in unchanneled sections, without ice; (6) the self-purification coefficient decreased in polluted water during summer and autumn only in the areas with high initial BOD values. It is concluded that canalization of Odra River has positive and negative features, of which the weirs which increase the amount
83
BASIC STUDIES reservoirs experi menta I photosynthesis
EQUIPMENT waste treatment diffusers
BASIC STUDIES waste treatment experimental reaeration
EQUIPMENT streams cascades
BASIC STUDIES streams experimental reaeration oxidation
M-Continued
of dissolved oxygen is the most important. The channel has negative effects such as accumulation of bottom sediment, hydrogen sulphide, and occurrence of oxygen deficiency
M-6 Marrucci, G Nicodemo, L COALESCENCE OF GAS BUBBLES IN AQUEOUS SOLUTIONS
OF INORGANIC ELECTROLYTES Chern Eng Sci v 22 n 9 Sep 1967 p 1257-1265
Measurements of average bubble size in bubble column have been taken by means of photographic method; liquid phase consisted of _aqueous solution of electrolyte and distributor was porous plate; number of different electrolytes were used, and superficial gas velocity was varied between 0.1 and 1.5 em/sec; coalescence phenomena which occur near distributor; proposed correlation relates average bubble diameter to gas flow rate and to group of electrolyte properties. 38 refs (EI 1968)
M-7 Maxworthy, T NOTE ON EXISTENCE OF WAKES BEHIND LARGE,
RISING BUBBLES J Fluid Mechanics v 27 pt 2 Feb 1967 p 367-368
Using simple flow-visualization techniques, it was observed that as large volume of air rises through quiescent liquid it produced well-defined wake and that drag on bubble appears as momentum defect within this wake (EI 1967)
M-8 McCloy, D CAVITATION AND AERATION-EFFECT ON VALVES AND
SYSTEMS Hydraulic Pneumatic Power v 12 n 133-134 Jan 1966 p 32-37 Feb 1966
p 100-105 Conditions that give rise to cavitation and aeration and effects of their presence in hydraulic systems are discussed; orifice cavitation and cavitation erosion in valves are studied; theoretical analysis of cavitation occurrence in actuators during step and frequency responses is supported by experimental results (EI 1966)
M-9 McDonnell, A J Hall, S D EFFECT OF ENVIRONMENTAL FACTORS ON BENTHAL OXYGEN UPTAKE
Water Pollution Abstracts Proc 22nd lnd Waste Conf Purdue U Eng Extn Ser No 127 1967 p 414-428 Preliminary results of laboratory experiments on the effect of various factors on the oxygen demand of benthic deposits collected from Spring Creek, a highly eutrophic stream in Pennsylvania, confirmed that the rate of oxygen uptake is dependent on oxygen concentration and independent of sample depth. The presence of measureable densities of macroinvertebrates also has a marked effect, and an attempt was made by a relatively simple procedure to approximate the demands associated with microbial and invertebrate respiration to determine the relative importance of each
84
BASIC STUDIES bubbles experimental
BASIC STUDIES bubbles experimental
CAVITATION
BASIC STUDIES streams experimental oxidation
M-Continued
M-10 McDonnell, Archie J Kountz, R Rupert ALGAL RESPIRATION IN A EUTROPHIC ENVIRONMENT J Water Pollution Control Federation v 38 n 5 May 1966 p 841-857
Present-day community development, especially in small watersheds, such as Spring Creek, Penn., has compounded problems of stream pollution criteria. In many stream situations, depletion of dissolved oxygen resources is a result not only of BOD but also of the effect of community respiration. Exactly how much effect each of these factors has on the dissolved oxygen level of the stream is difficult to evaluate. With statisti~al methods of regression and variance analysis, it was possible to define the BOD parameter as one of secondary engineering significance and to evaluate quantitatively the nocturnal oxygen demands of a heterogeneous stream flora. Community plant respiration varies directly with stream temperature and inversely with streamflow. Chemical analysis of contributing sources indicated nutrient concentrations sufficient to induce and maintain a eutrophic environment .
. On this basis, where population-to-receiving water resource ratio is high, analysis for significance of parameters other than BOD should be made and the findings manifested in the treatment process. The solution appears to lie in the removal of nitrogen and phosphorus from the waste water treatment plant effluent before it enters the creek waters, which practically implies total exclusion (Jones-Wis) W69-10159
M-11 McKinney, R E Benjes, H H Jr EVALUATION OF TWO AERATED LAGOONS Proc ASCE v 91 n SA 6 Dec 1965 p 43-55
Field studies of two aerated lagoons treating domestic sewage over 2-yr period yielded 63 percent BOD reduction with 1. 7 days aeration and 78 percent BOD reduction with 7.1 days aeration; use of oxidation ponds after using aerated lagoons increased BOD reductions to 85 and 88 percent; it appeared that mechanical aerators-mixers could produce complete mixing with from 1/5 to 1/4 hp/1 ,000 cu ft aeration volume; bacterial cells were primarily responsible for effluent BOD from aerated lagoon; algae were responsible for effluent BOD from oxidation ponds (EI 1966)
M-12 McWhirter, J R FUNDAMENTAL ASPECTS OF SURFACE AERATOR
PERFORMANCE AND DESIGN Purdue U-Eng Extn Ser 118 1965 p 75-92
Discussion of several methods for determination of oxygenation; unsteady-state reaeration is most widely used and accepted method; steady-state technique gives results about 10 percent higher · than unsteady-state technique; sulfite oxidation data shows higher oxygen uptake rates than steady-state data with different temperature variation and significant variation in oxygen uptake rate with different catalysts. 24 refs (EI 1967)
M-13 Mercier, P Perret, J AERATION STATION OF LAKE BRET Monatsbull Schweiz Ver Gas- u Wasserfachm v 29 1949 p 25 Water Pollution Abstracts v 40 1950 p 533
Attempts to aerate a stratified lake by withdrawing water, aerating, and returning to the same depth
85
BASIC STUDIES streams experimental respiration
EQUIPMENT waste treatment mechanical
aerators
EQUIPMENT mechanical
aerators
EQUIPMENT reservoirs mise equipment
M-Continued
M-14 Mer-cier, P Gay, S EFFECTS OF ARTIFICIAL AERATION ON WATERS OF
LAKE BRET Rev Suisse d'Hydrologie v 16 1954 p 2
Reports on aerating water in a stratified lake by withdrawing water, aerating, and returning to same depth
M-15 Metzger, I Dobbins, WE THE ROLE OF FLUID PROPERTIES IN GAS TRANSFER Environmental Sci and Tech v 1 1967 p 57
M-16 Metzger, I SURFACE EFFECTS IN GAS ABSORPTION Environmental Sci and Tech v 2 1968 p 784
M-17 Metzger, Ivan EFFECTS OF TEMPERATURE ON STREAM AERATION Proc ASCE v 94 n SA 6 Dec 1968 p 1153-1159
The effect of temperature on the aeration of receiving waters is often described by an equation of the form KT = K20 () (T-20) where K20 is the 20° value of the absorption coefficient and KT is the value at some other temperature, T. In the past, () has been considered to be a constant with various values assigned to it by different investigators. It is shown that () is not a constant but depends on the level of turbulence and temperature. Values of () appropriate for streams are determined by using the film penetration model and experimental results. These values are compared with values reported in the literature
M-18 Miyamoto, S A THEORY OF THE RATE OF SOLUTION OF GAS
INTO LIQUID Bull Chern Society of Japan v 7 n 1 1932 v 7 n 12 Dec 1932 v 5 n 4 Apr 1930
M-19 Morgan, P F MAINTENANCE OF FINE BUBBLE DIFFUSION Proc ASCE v 84 n SA 2 Apr 1958
As a result of a 2-year laboratory study at the State University of Iowa, it has been confirmed that diffuser media can be clogged externally by a number of specific materials in the tank liquor, and internally by particulate matter in the air supply. Further, it was found that all forms of external clogging are aggravated by particulate matter in the air supply.
Corrective measures are proposed for each of the causes of clogging but because particulate matter is the most important it is recommended that it be corrected first. The commonly accepted standard for air quality of 0.5 mg/1 ,000 cu ft is shown to be unsatisfactory under certain conditions. A new standard of 0.1 mg/1,000 cu ft is proposed. Plant operating records are prP.sented to show that a clogging problem was eliminated after the installation of precoated bag filters producing air meeting this standard. The corrective measures for other specific causes of clogging can be effectively applied only after the air supply is adequately filtered
86
EQUIPMENT reservoirs mise equipment
BASIC STUDIES reaeration
BASIC STUDIES reaeration
BASIC STUDIES streams experimental reaeration
BASIC STUDIES theoretical reaeration
EQUIPMENT waste treatment diffusers
M-Continued
M-20 Morgan P F Bewtra, J K AIR DIFFUSER EFFICIENCIES J Water Pollution Control Federation v 32 n 10 1960 p 1047
. M-21 Morgan, P F Bewtra, J K
DIFFUSED AIR OXYGEN TRANSFER EFFICIENCIES paper presented at Conference on Biological Waste Treatment Manhattan College
1960
M-22 Morgan, P F Bewtra, J K DETERMINATION OF OXYGEN UPTAKE RATE BY
POLAROGRAPH METHOD J Water Pollution Control Federation v 34 1962
M-23 Morris, James S Krenkel, P A Thackston, E L INVESTIGATIONS ON TURBULENT DIFFUSION IN
INLAND WATERWAYS Tech Report No. 14 Sanitary and Water Res Eng Vanderbilt U Nashville Tenn
1966
M-24 Morris, J V McGill, L H Rutherford, C C MECHANICAL AERATORS TESTED AT LONDON'S
"GREENWAY" POLLUTION CONTROL CENTRE Water and Pollution Contra I v 106 n 1 Jan 1968 p 30-32
Paper summarizes results of program of acceptance tests of mechanical aerators supplied at Lonoon, Ontario, sewage treatment facilities; work involved reconstruction and renovation of existing primary, aeration and final tanks to bring their capacity to 7 mgd; economic analysis indicated desirability of employing mechanical aerators to supply oxygen necessary for new activated-sludge secondary-treatment plant which would operate as third, parallel section of total works (EI 1968)
M-25 Morris, R M MASS TRANSFER AND BUBBLE SIZES IN SOLID-LIQUID-GAS SYSTEMS
Chern and I nd n 44 Oct 1964 p 1836-1837 Contacting of gas and liquid with suspended solids in vessel with rotating impeller; applicability to fermentation processes such as yeast and antibiotics manufacture, aeration of activated sewage sludge, and catalytic hydrogenation and chlorination reactions; of specific industrial interest is scrubbing of flue gases (10 percent C02) by means of calcium hydroxide slurry in agitated vessel, and precipitation of whiting for plastics and paint industries (EI 1965)
M-26 Marti mer, C H THE EXCHANGE OF DISSOLVED SUBSTANCES BETWEEN
MUD AND WATER IN LAKES J Ecol v 29 1941 p 280-329; v 30 1942 p 147-201
M-27 Muenz, K Marchello, J M SURFACE MOTION AND GAS ABSORPTION A I Ch E J v 12 n 2 Mar 1966 p 249-253
Influence of small waves on mass transfer from pure gases into water is investigated; small-amplitude progressive two-dimensional waves are
87
EQUIPMENT diffusers
EQUIPMENT waste treatment diffusers
DO ANALYSIS instrumentation
BASIC STUDIES streams experimental
EQUIPMENT waste treatment mechanical aerators
EQUIPMENT waste treatment mise equipment
BASIC STUDIES reservoirs experimental
BASIC STUDIES experimental reaeration
M-Continued
mechanically generated at liquid surface for wave studies; control experiments with nonwaved surfaces are also conducted; effect of surface motion arising from Marangoni instability is considered for nonwaved surface; effective diffusivity is used to correlate data (EI 1966)
M-28 Murphy, G I EFFECT OF MIXING DEPTH AND TURBIDITY ON THE PRODUCTIVITY OF FRESH-WATER IMPOUNDMENTS
Trans American Fisheries Society v 91 n 1 1962 p 69-76
88
BASIC STUDIES reservoirs
N
N-1 Nems, E I Tokmakov, V I Chigareva, T S 0 ZAVISIMOSTI FOAMY POVERKHNOSTNYKH PUZYR'KOV
(KAPEL) OF IKH RAZMERA Akademiya Nauk lzvestiya Energetika i Transport n 2 Mar-Apr 1967
p 146-149 Shape of surface bubbles as dependent on their size; change of shape of bubbles during growth was studied; it is shown that base of growing bubble first crawls apart but later contracts until onset of breakoff. In Russian (EI 1968)
N-2 Nesmeyanov, S.A
N-3
DONNYE OTLOZHENIYA I KILORODNYI REZHIM VODOEMOV (Benthic Deposits and the Oxygen Regime of Reservoirs)
lzd-vo Akad Med Nauk USSR Moscow 1950 157 p In Russian
Nicholas, W R Bewtra, J K EFFECT OF SUBMERGENCE ON AERATION DEVICES IN OXGENATION IN AERATION TANKS
presented at the 35th Annual Meeting of the Central States Water Pollution Control Assoc Duluth 1962
N-4 Nicholas, W R AERATION SYSTEM DESIGN presented to the Sanitary Eng lnst U of Wis Madison Wis 1965
N-5 Novak, R G TECHNIQUES AND FACTORS INVOLVED IN AERATOR
SELECTION AND EVALUATION J Water Pollution Control Federation v 40 n 3 pt 1 Mar 1968 p 452-463
Methods, results, and data reliability obtained during in-place, steady-state evaluation of two different types of aeration equipment for chemical wastes are presented; oxygen transfer efficiency of installed system of mechanical aerators was estimated by measuring oxygen uptake and power; COD, BOD, sludge volume index, suspended solids, and mixed liquor velocity were evaluated (EI 1968)
N-6 Novotny, V ON THE DIFFUSION PHENOMENON IN BOUNDARY LAYERS
OF TURBULENT FLOW AND ITS INFLUENCE ON THE COURSE OF SELF-PURIFICATION OF SMALL STREAMS
Water Res v 2 n 6 1968
89
BASIC STUDIES bubbles experimental
BASIC STUDIES reservoirs oxidation
EQUIPMENT waste treatment
EQUIPMENT waste treatment diffusers
EQUIPMENT waste treatment mechanical aerators
BASIC STUDIES I
streams reaeration '
0-1
0·2
0-3
0-4
0-5
0
O'Connell, R L Thomas, N A EFFECT OF BENTHIC ALGAE ON STREAM DISSOLVED OXYGEN
Proc ASCE v 91 n SA 3 Jun 1965 p 1-16 The effects of respiratory oxygen uptake by photosynthetic benthos on the water quality of streams is examined. Methods for evaluating these effects are given together with results obtained in a survey of the Truckee River. The signficance of daily minimum dissolved oxygen concentrations in streams is considered and techniques for prediction of this value incorporating benthic algal effects are described
O'Connor, D J Dobbins, W E THE MECHANISM OF REAERATION IN NATURAL STREAMS Proc ASC E v 82 n SA 6 1956 p 1115
Develops a theoretical model for reaeration of a turbulent system
O'Connor, D J THE MEASUREMENT AND CALCULATION OF STREAM
REAERATION RATIO Oxygen Relationships in Streams Tech Report No. W-58-2 Taft Sanitary Eng
Center 1958
0 'Connor, D J OXYGEN BALANCE OF AN ESTUARY Proc ASCE v 86 n SA 3 May 1960
The net seaward movement of organic impurities in estuaries is due to the displacement by the land runoff and to the longitudinal diffusion of the tidal action. The dissolved-oxygen profile depends on the concentration of the organic materials, its rate of oxidation, and the resulting rate of reaeration. The interrelationship among these geophysical and biochemical factors is described by a differential equation under a steady-state condition. The assumption of constant coefficients in the equation is confirmed by the field data from estuarine surveys of the Delaware and the James Rivers. Dissolved-oxygen profiles are calculated from the integrated equation and compared to the measured dissolved-oxygen concentrations. The turbulent diffusion coefficient and the deoxygenation rate are determined from an analysis of survey data and are used in the calculation of the oxygen profiles. The agreement between the calculated profiles and the observed values is sufficiently close to justify the use of the equations for the conditions assumed in the development
O'Connor, D J TEMPORAL AND SPATIAL DISTRIBUTION OF DISSOLVED
OXYGEN IN STREAMS Water Resources Res v 3 n 1 First Quarter 1967 p 65-79
Geophysical characteristics of drainage basin and biochemical and physical environment of river affect concentration of dissolved oxygen, these factors are embodied in fundamental equation of continuity that describes oxygen balance, variation of fresh-water flow and cross-sectional area is included, as well as various sources and sinks of oxygen-natural and artificial aeration, photosynthetic contribution, bacterial and algae respiration, carbonaceous and nitrogenous oxidation, and benthal deposits (EI 1967)
90
BASIC STUDIES streams experimental respiration
BASIC STUDIES streams theoretical '
BASIC STUDIES streams experimental reaeration
BASIC STUD:IES estuaries theoretical · experimental
BASIC STUDIES streams reaeration oxidation
0-Continued
0-6 Ogunrombi, J A THE EFFECTS OF BENTHAL DEPOSITS ON THE OXYGEN
RESOURCES OF NATURAL STREAMS Water Pollution Abstracts thesis New York U 1968 Dissertation Abstracts v 29 n B 1969 p 3343
Benthal deposits are known to exert oxygen demands on the overlying water, and it is suggested that this occurs in two ways-by addition of organic matter from the deposits, to the water, thus increasing the BOD of the water; and by the removal of dissolved oxygen from the water to satisfy both the BOD of organic matter in the top aerobic layer and the intermediate COD of products of anaerobic decomposition which diffuse to the aerobic zone from the deeper layers. Laboratory experiments were carried out to verify the existence of these processes and the results indicated that the rate of transfer of organic matter from the benthal deposits to the supernatant water is smaller than the rate at which dissolved oxygen is abstracted from the water by the deposits. For any sludge depth, the total oxygen demand of the deposit is less than the potential aerobic demand of the sludge
0-7 Oldaker, W H Burgun, A A Pahren, H R PILOT-PLANT STUDY OF BENTHIC OXYGEN DEMAND
OF RIVER BOTTOM SEDIMENTS J Water Pollution Control Federation v 40 n 10 Oct 1968 p 1688
0-8 Orlob, G T EDDY DIFFUSION IN HOMOGENEOUS TURBULENCE Proc ASCE v 85 n HY 9 Sept 1959 p 75-103
0-9 Owens, M Edwards, R W Gi._bbs, J W SOME REAERATION STUDtE~ IN STREAMS Air and Water Pollution v 8 n 8-9 Sept 1964 p 469-486
Reaeration coefficients of several reaches of lowland and lake district streams were determined and correlated with some of hydraulic characteristics of streams to see if observed reaeration coefficients agree with those calculated from equations proposed by previous workers; empirical equation is derived from which it is possible to predict reaeration rate which could be expected in rivers from their mean velocities and depths, provided these are within experimentally observed ranges. 27 refs (EJ 1965)
0-10 Owens, M Knowles, G THE PREDICTION OF THE DISTRIBUTION OF DISSOLVED
OXYGEN IN RIVERS Water Res v 2 1968 p 20
91
BASIC STUDIES streams experimental oxidation
BASIC STUDIES streams
.oxidation
BASIC STUDIES streams
BASIC STUDIES streams experimental reaeration
BASIC STUDIES streams reaeration
P-1
P-2
P-3
P-4
P-5
P-6
p
Palladino, A J INVESTIGATION OF METHODS OF STREAM IMPROVEMENT lnd Water and Wastes v 6 n 3 1961 p 87
Includes evaluation of turbine venting and diffusers for reaeration of Kalamazoo River in Michigan. The stream is heavily polluted with paper mill wastes. Turbine venting added 2 lb/kwhr, with initial DO less than I mg/1. 0.5 mg/1 was added through venting. Vent noise indicated undersizing. Drilled pipe diffusers resulted in 1 mg/1 pickup with airflow of 570 cfm, or 0.6 mg/1 at 325 cfm. Efficiency thus was 1.6 to 1.7 percent, or about 0.51b/kwhr. Initial DO was 2 to 3 mg/1
Panaiotti, S S VLIYANIE RASTVORENNOGO V ZHIDKOSTI GAZA NA
KAVITATSIONNYE KHARAKTERISTI Kl lzvestiya Vysshikh Uchebnykh Zavedenii Mashinostronie n 4 1968 p 95~100
Influence of gas dissolved in liquid upon cavitation characteristics; cavitating flows around cylindrical profile were examined for cases of water-air and water-carbon-dioxide systems; it was found that variations of gas content in water have no practical effect on values of characteristic coefficients of cavitation; applicable to cavitation in pumps. In Russian (EI 1968)
Parker, Frank L EDDY DIFFUSION IN RESERVOIRS AND PIPELINES ProcASCE v87 nHY3 May1961 p151-171
Ocean eddy current diffusion coefficient is a function of eddy size, which is confirmed by reservoir tests with radioactive tracers. Tests of eddy diffusion in pipelines are compared with Taylor's solution; pipeline coefficients are greater because of obstructions and curved sections in the pipe
Pasveer, A A STUDY OF THE AERATION OF WATER Res on Activated Sludge I Sewage and I nd Wastes v 25 n 11 Nov 1953 p 1253
Pasveer, A Sweeris, S NEW DEVELOPMENT IN DIFFUSED AIR AERATION J Water Pollution Control Federation v 37 n 9 Sept 1965 p 1267-1274
Application of study on oxidation-ditch system for purification of smaller quantities of domestic and industrial wastes to investigate whether it is possible to use diffused-air system in horizontal flow of mixed liquor, steel ring-shaped aeration tank was constructed in which it was possible to achieve horizontal flow by paddle-wheel arrangement; experiments were performed at various velocities of horizontal flow; quantity of oxygen taken up per 100 em of water-column was determined as percentage from weight of oxygen introduced with air (EI 1966)
Pasveer, A CONSIDERATIONS ON EFFICIENCY OF AERATION PROCESS Air and Water Pollution v 10 n 8 Aug 1966 p 477-493
Possibility of achieving higher efficiencies in aeration processes than are achieved in practice is considered; according to theory of aeration, besides creation of large interface of water and air, rapid renewal of this interface is also of great importance; it is found that in methods of diffused air aeration, only 1 0 percent of gross energy expended is used for surface creation and surface renewal; improvement in diffused air efficiency could be achieved by
92
EQUIPMENT streams turbine injection diffusers
CAVITATION
BASIC STUDIES reservoirs experimental
EQUIPMENT waste treatment
EQUIPMENT waste treatment diffusers
EQUIPMENT waste treatment diffusers
P-7
P-9
P-10
P-11
P-12
P--Continued
avoiding "spiral flow" and "ridge and furrow" systems by means of "horizontal flow" system and by using smaller air bubbles. 26 refs (EI 1967)
Patriarche, Mercer H AIR-INDUCED WINTER CIRCULATION OF TWO SHALLOW
MICHIGAN LAKES J Wildlife Management v 26 1961 p 289
Patterson, Calvin C Gloyna, Earnest F DISPERSION MEASUREMENT IN OPEN CHANNELS Proc ASCE v 91 n SA 3 Jun 1965
Pence, G D Jeglie, J M Thomann, R V TIME-VARYING DISSOLVED OXYGEN MODEL Proc ASCE v 94 n SA 2 1968 p 381
Pearson, E A discussion of THE MEASUREMENT AND CALCULATION
OF STREAM REAERATION RATIO by D. J. O'Connor Oxygen Relationships in Streams Tech Report No. W-58-a2 Taft Sanitary Eng
Center 1958
Peskin, R L LAWS OF DISPERSION Water Resources Research Institute Report Rutgers Univ Oct 1969
Two problems on the laws of dispersion for materials such as small particles and gas bubbles in turbulent streams are considered. After discussing the mechanisms of single-particle dispersion, a statistical approximation model is used to calculate two-particle dispersion. Specifically, the Eulerian fluid velocity which appears in the equation of motion of a small particle is replaced by a random best estimate. This estimate is obtained by prediction techniques using specified statistical properties of the turbulence field. The second problem considered is that of gas bubble dispersion. An approximate analysis is used to estimate the spread of bubbles from a line source of bubbles. Buoyancy and turbulence inhomogeneity effects, which result in a bubble size segregation, are evaluated
Pfeffer, John T EVALUATION OF AERATOR CAPABILITIES FOR WASTE WATER TREATMENT
Tappi v 52 n 9 1969 p 1652-1655 Studies of aeration systems have shown a need for evaluation of aeration equipment operating under field conditions. Procedures have been developed for rating aerators, by using clean water as standard test conditions. Studies of the effects of waste water characteristics have shown that the oxygen transfer capacity of an ae-ration system can be significantly changed from the rated capacity. These effects are discussed and related to industrial waste water flows, particularly pulp and paper. Techniques for evaluation of systems operating under field conditions have been developed. These techniques are discussed and results of field studies are presented. Procedures for the determination of correction factors are given
93
EQUIPMENT reservoirs diffusers
BASIC STUDIES streams experimental
BASIC STUDIES streams reaeration
BASIC STUDIES streams ex peri menta I reaeration
BASIC STUDIES theoretical reaeration
EQUIPMENT waste treatment
P-13
P-14
P-15
P-16
P-17
P-18
P-Continued
Pfeffer, J T Hart, F C Schmid, LA FIELD EVALUATION OF AERATORS IN ACTIVATED SLUDGE SYSTEMS
Water and Sewage Works v 115 1968 p 520
Phelps, E B STREAM SANITATION John Wiley and Sons, Inc New York N Y 1944
Plateau, J A F STATIQUE DES LIQUIDS Paris 1873 v 1 c 5
Presents the laws of bubble geometry based on minimizing surface area of liquid films; the laws are: 3, and only3, foam lamellae meet at an edge-the 3 coplanar angles at which they are inclined to each other are all equal, each is 120° In French
Poon, C PC THEORETICAL CONCEPT OF OXYGEN TRANSFER IN
GAS BUBBLE AERATION SYSTEM Water and Sewage Works v 113 Nov 30 1966 p R200-202 204-205
Proposed theory and mathematical treatment of gas transfer process is presented with statistics of molecular motion and turbulent diffusion; single gas-liquid boundary layer is considered instead of two films which have been generally accepted as controlling factors; readily soluble gas is one which as high a-value, specifying fraction of gas molecules striking bubble wall and condense; therefore thickness of liquid film-turbulent diffusion zone in this theory, controls rate of absorption since it will be slower step; on the other hand, less soluble gas will be limited by thickness of gas-film, a-value in theory, and not by liquid film; proposed theory is more direct and easier to be followed (EI 1967)
Poon, C PC Campbell, H DIFFUSED AERATION IN POLLUTED WATER Water and Sewage Works v 114 n 12 Dec 1967 p 461-463
Effect of dissolved chemicals in water on transfer process was studied in series of experiments; pyrex column of 5-1/2 in ID was built 12 feet high measured from top of diffusers to top of column; fritted glass diffusers were installed at bottom of column; temperature of water in column for all experiments was automatically held constant using thermostat with immersion heater; experiments were run at water depth of 7.0 ft above top of diffuser and rate of airflow was maintained at constant of 300 cc/min; temperature was held constant at 20° Cor otherwise diffusion coefficient was corrected to 20° C. 10 refs (EI 1968)
Poon, C P C Lee, F SURFACE AERATION BY MECHANICAL AGITATION Water and Sewage Works v 116 n 7 Jul 1969 p 262
In experiments with mechanical aeration in laboratory-scale circular tanks, various factors affecting the oxygen absorption coefficient were studied, including the degree of submergence of the rotor blades, rotor speed, and water depth. The overall oxygen absorption coefficient increase significantly with increasing rotor size at high speeds
94
EQUIPMENT waste treatment
BASIC STUDIES streams reaeration
BASIC STUDIES bubbles theoretical
BASIC STUDIES bubbles theoretical
EQUIPMENT diffusers
EQUIPMENT mechanical aerators
P-19
P-2p
P-Continued
Poston, H W Ownbey, C R THE GREAT LAKES WATER RESOURCE J American Water Works Assoc v 60 n 1 Jan 1968 p 15-20
The problems of eutrophication, increase of chemicals, and oxygen depletion are discussed. Measures presently being taken are presented, including Federal grants. Legally, the 1udicial process has been inadequate to resolve the problems created by the conflicting interest for the use of the water. The Great Lakes belong to all the people of the United States and Canada, but the problem is who should be the custodian of these waters. A Board of Directors, similar to that governing the Tennessee Valley Authority, is proposed. The representation of the states bordering the Great Lakes, the Province of Ontario, and the Governments of the United States and Canada is discussed
Purdy, R W WHAT DO WE KNOW ABOUT NATURAL PURIFICATION? Proc ASCE v 94 n SA 1 Feb 1968 p 1-11
It is possible to predict effect of stabilization of oxidizable substances on DO content of stream; time of flow can be calculated on basis of displacement of occupied channel volume but calculations should be checked by observing time of passage with fluorescent dye; effect of sludge deposits, biological extraction and accumulation, and oxidation of nitrogenous substances on DO balance in stream can be evaluated and examples of such evaluations are presented. 11 refs ( El 1968)
95
GENERAL
BASIC STUDIES streams reaeration
0-1
0-2
Q
Quigley, J T EFFECTIVENESS AND COSTS OF VARIOUS TYPES OF MECHANICAL REAERATION FOR RIVERS AND IMPOUNDMENTS
Unpublished paper presented to the Seminar in Water Resources Planning U of Wis Madison Wis Apr 1969
Describes problem of generalizing four alternative aeration systems for purposes of cost comparison: (1) porous diffuser system, (2) perforated tubing system, (3) mechanical surface aerator, and (4) hydraulic turbine injection
Quirk, T P Eder, L J EVALUATION OF ALTERNATIVE SOLUTIONS FOR ACHIEVEMENT OF RIVER STANDARDS
J Water Pollution Control Federation v 42 n 2 pt 1 1970 p 272 A river of approximately 170 miles (274 km) in length and 3,500 sq miles (9,965 sq km) in drainage area is studied. The purpose of the study was to: determine the physical characteristics, develop a mathematical simulation model to predict BOD and DO profiles under any condition of flow, temperature, or waste discharge, and application of the model to investigate BOD assimilation capacity under critical weather and flow conditions. The effects of sludge deposits, hydroturbine venting, and flow augmentation are determined. The model also was used to determine the comparative economics of alternative solutions for the achievement of proposed water-quality standards. The effects of channel geometry, sludge composition, location, depth, oxygen uptake rates, point aeration, riverflow, and seiche wave effect were plugged into the model. Seven solution components were analyzed and the results, used by regulatory personnel and industry, culminated in the establishment of a common basis for interpretation of the financial requirements and practical capability of achieving various levels of water quality improvement
96
EQUIPMENT streams reservoirs turbine injection diffusers mechanical aerators
economics
BASIC STUDIES streams theoretical experimental reaeration oxidation EQUIPMENT turbine injection
R-1
R-2
R
Ragone, Stanley Peters, B J WATER QUALITY MONITORING FOR WATER QUALITY
CONTROL US Dept Health Education Welfare Symposium on Streamflow Regulation for
Quality Control Public Health Service Pub No 999-WP-30 1965 Describes submerged weirs at Gaston Dam and Roanoke Rapids Dam designed to prevent discharge of cold, oxygen-deficient water; weirs skim off oxygen-rich surface layers of water and prevent density currents from entering intakes
Rasmussen, D J-:1
PREVENTING A WINTERKILL BY USE OF A COMPRESSED AIR SYSTEM
Progressive Fish Culture v 24 1960 p 185 Reports on compressed air mixing of lakes to prevent fish winterkill when the lake freezes over and cuts off the oxygen supply
R-3 Redfield, J A Houghton, G MASS TRANSFER AND DRAG COEFFICIENTS FOR SINGLE
BUBBLES AT REYNOLDS NUMBERS OF 0.02-5000 Chern Eng Sci v 20 n 2 Feb 1965 p 131-139
Simultaneous dilatometric and photoelectric determinations of mass transfer and velocity of rise, respectively, have been made for a single bubbles of C02 rising in pure water and aqueous solutions of dextrose; although boundary layer and potential flow models predict orders of magnitude and general trends for drag and mass-transfer coefficients at Re greater than 1, detailed comparison is masked by changes in shape and motion of bubbles as well as presence of turbulence in wake. 35 refs (EI 1965)
R-4 Reid, L C Jr AERATED SEWAGE LAGOON IN ARCTIC ALASKA Western Canada Water and Sewage Conf 17th Annual Convention-Papers
Sep 1 5-17 1 965 p 1 01-113 Observations and results of study conducted by Arctic Health Research Center, with cooperation of Air Force of Alaskan Air Command, during winter of 1964-65 on aerated sewage pond receiving settled domestic sewage at Eielson Air Force Base; pond is located 25 miles from Fairbanks, in central valley of Alaska area which ordinarily experiences coldest winter temperatures in United States; Air-Aqua System provides aeration and lagoon operates on extended aeration principle; rising action of air bubbles divides lagoon into 15 individual cells which are continually being mixed; activated sludge agglomerates until particles are too large to remain in suspension, whereupon it settles and digests on lagoon floor (EI 1967)
R-5 Revelle, C S Loucks, D P Lynn, W R LINEAR PROGRAMMING APPLIED TO WATER QUALITY MANAGEMENT
Water Resources Res v 4 n 1 1968 p 1
R-6 Revelle, C S Loucks, D P Lynn, W R A MANAGEMENT MODEL FOR WATER QUALITY CONTROL J Water Pollution Control Federation v 39 n 7 Jul1967 p 1164
97
BASIC STUDIES reservoirs experimental
EQUIPMENT reservoirs diffusers mise uses
BASIC STUDIES bubbles experimental
EQUIPMENT waste treatment diffusers
GENERAL
GENERAL
R-7
R-8
R-Continued
Riddick, Thomas M FORCED CIRCULATION OF RESERVOIR WATERS Water and Sewage Works v 104 n 6 1957 p 231-237
Compressed air mixing of 246 acre-ft reservoir at Ossining, N. Y. completely destratified and recirculated the water almost twice a day
Rincke, G Moeller, U MESS- UNO VERFAHRENSTECHNISCHE MOEGLICHKEITEN
FUER EINE AUTOMATISCHE REGELUNG DER SAUERSTOFFZUFUHR IN BELUEFTUNGSBECKEN
Vom Wasser v 34 1967 p 297-333 Measurement and technical process possibilities for automatic control of oxygen supply to aeration basins; literature revew of devices for analysis of oxygen contents in aeration basins; first continuous analyzer and controller by G. Stracke is described; effects of various parameters on devices sensitivity, accuracy of commercial-scale tests, and results. 38 refs. In German (EI 1968)
R-9 Robertson, J M CAVITATION IN HYDRAULIC STRUCTURES: SCALE
EFFECTS INVOLVED IN CAVITATION EXPERIMENTS Proc ASCE v 89 n HY 3 May 1963 p 167-180
The general nature and purpose of experimental studies of cavitation-susceptible hydraulic structures is reviewed. Scale effects are defined as deviations in the cavitation occurrences from the simple concept of cavitation in a liquid of given density and vapor pressure, resulting from other fluid properties and occurrences. For simple bodies, known scale effects are shown to be characterized sometimes by the Reynolds number and sometimes by a dimensional parameter V yd. The effects of protuberances or roughnesses in terms of boundary-layer thickness and location on the body are indicated as potential sources of large effects. Possible effects of air content on cavitation scaling are also noted
R-10 Roe, F C
R-11
THE INSTALLATION AND SERVICING OF AIR DIFFUSER MEDIUMS
Water and Sewage Works v 81 1934 p 450
Rolley, H L J Owens, M OXYGEN CONSUMPTION RATES AND SOME CHEMICAL
PROPERTIES OF RIVER MUDS Water Res v 1 1968 p 759
Rates of oxygen consumption varying from 0.006 to 0.41 g/m2/hr were obtained during an investigation of sediments collected from 74 sites in 12 river systems during January-February and July-August 1966. The distribution of these rates was similar in both surveys and no correlation was found between rates of oxygen consumption and any chemical property of the mud. Strong correlations were obtained between all the chemical properties examined: permanganate value, loss on ignition, and contents of humic acid, org. C, and Kjeldahl N. Deposits in reaches below outfalls from sewage-treatment works operating percolating filters to a nominal effluent standard of 30 mg/1 suspended solids and 20 mg/1 BOD were not found to differ significantly from those in unpolluted reaches. However, both were significantly different from deposits downstream of outfalls from works using the activated sludge process
98
EQUIPMENT reservoirs diffusers
DO ANALYSIS instrumentation
CAVITATION
EQUIPMENT diffusers
BASIC STUDIES streams experimental oxidation
R-12
R-13
R-Continued
Ross, Sydney BUBBLES AND FOAM lnd and Eng Chern v 61 n 10 Oct 1969 p 48-55
The general law of bubble geometry takes into account the minimizing of surface area required to contain a given amount of gas at a given temperature and given pressure
Rozen, AM PROBLEMY TEORII I INZHENERNOGO RASCHETA
PROTESESSOV MASSOOBMENA Khimicheskaya Promyshlennost n 2 Feb 1965 p 5-11
Problems of theoretical studies and engineering calculations of mass exchange processes; development of theory of mass exchange; measurements and calculations of contact surface in liquid-gas and liquid-liquid systems; theory of scalar transitions concerned with transversal irregularity in large-diameter apparatus. In Russian {EI 1966)
R-14 Ruckenstein, E A GENERALIZED PENETRATION THEORY FOR UNSTEADY
CONVECTIVE MASS TRANSFER Chern Eng Soc {Brit) v 23 n 4 1968 p 363
R-15 Ryder, Robert A DISSOLVED OXYGEN CONTROL IN ACTIVATED SLUDGE I nd Water Eng v 6 n 9 1969 p 43-45
The control of the dissolved oxygen concentrations in activated sludge to ± 0.2 percent mg/1 results in a continuous response to changing oxygen demands, reduced power consumption, and suppression of filamentous organism growth (sludge bulking). The volume of air directed to three aeration tanks and a post-aeration tank was regulated by butterfly valves responsive to both waste and dissolved oxygen content. The aeration pattern was varied to match the desired aeration profile by adjusting the number of diffusers on each swing header. Sludge bulking was decreased when the dissolved oxygen levels were kept at 0.75 to 1.0 and 0 mg/1 in the aeration and sedimentation tanks, respectively. Rohm and Haas {C-7) polyelectrolyte increased the zone settling rate by a factor of 10 in the laboratory and afforded immediate relief to sludge bulking until a stable sludge was obtained by dissolved oxygen control
99
BASIC STUDIES bubbles theoretical
BASIC STUDIES theoretical reaeration
BASIC STUDIES theoretical reaeration
EQUIPMENT waste treatment diffusers
S-1
S-2
S-3
S-4
S-5
S-6
S-7
s
Schade, W F Wirts, J J DIFFUSER PLATE CLEANING VERSUS COMPRESSED AIR
COST Sewage Works J v 14 1942 p 81
Schmitz, William R Hasler, Arthur D ARTIFICIALLY INDUCED CIRCULATION OF LAKES BY
MEANS OF COMPRESSED AIR Sci v 128 1958 p 1 088
Schrock, V E Perrais, J P DYNAMICS OF BUBBLES IN KNOWN TEMPERATURE
DISTRIBUTION Heat Transfer and Fluid Mechanics lnst 19th-Proc Jun 22-24 1966 p 122-147
Experimental investigation of bubble growth rates and shapes was conducted using system in which thermal environment is known; this was accomplished by viewing from two directions those bubbles which were first nucleated on transiently heated surface;· to vary thickness of superheated liquid layer and steepness of temperature profile at time of nucleation, subcooling, pool pressure, and heating schedule were varied appropriately; this produced superheat thicknesses ranging from 2 to 12 mils while maximum bubble size ranged from 12 to over 110 mils; shape factors were defined and determined over bubble lifetime. 24 refs (EI 1967)
Scott, W Foley, A L A METHOD OF 01 RECT AERATION OF STORED WATERS Reprinted from Proceedings of the Indiana Academy of Science for 1919, Aug 1921
Describes very early application of diffusers to reaeration of a small reservoir
Scott, R H Wisniewski, T F HYDRO-TURBINE AERATION OF RIVERS WITH SUPPLEMENTAL
OAT A ON CASCADES AERATION Pulp Paper Mag Canada v 61 Feb 1960 p T45
In addition to discussion of turbine venting efficiencies covered in other references by these authors, the paper briefly discusses the determination of true power loss. Although power output is reduced, water is also saved for later generation, thus partially offsetting the cost of power loss. Also discusses aeration by cascades
Scott, R H Wisniewski, T F Lueck, B F Wiley, A J AERATION OF STREAM FLOW AT POWER TURBINES Sewage and I nd Wastes v 30 n 12 Dec 1958 p 1496-1505
Describes results of turbine venting at Pixley Dam on Flambeau River, Wis. in June and July of 1957. Indicated gross gain of 525 to 9,471 lb/day-1,000 cfs. Maximum absorption efficiency of 37.3 percent. Maximum DO gain was 4.87 lb/kwhr of power loss. Injection was in annular space between runner ring and conically shaped part of draft chest which surrounds the runner ring. Turbines were double-runner horizontal type
Shapiro, J THE CAUSE OF A METALIMNETIC MINIMUM OF
DISSOLVED OXYGEN Limnol and Oceanog v 5 n 2 1960 p 216-227
100
EQUIPMENT diffusers economics
EQUIPMENT reservoirs diffusers
BASIC STUDIES bubbles experimental
EQUIPMENT reservoirs diffusers
EQUIPMENT streams turbine injection cascades
EQUIPMENT streams turbine injection
BASIC STUDIES reservoirs experimental oxidation
S-8
S-9
S-10
S-11
S-12
S-13
S-Continued
Shastry, J S Fan, L T Erickson, L E Yao, Kuan M discussion of REAERATION PREDICTION IN NATURAL STREAMS
by Edward L. Thackston and Peter A. Krenke! Proc ASCE v 95 n SA 6 Feb 1969 p 1186-1202
Shaver, J W Canter, L W Rowe, D R PERFORMANCE STUDY OF MUNCIPAL EXTENDED
AERATION PLANT Pub Works v 99 n 3 Mar 1968 p 85-87 148
Study involved comprehensive examination of performance of extended aeration modification of activated sludge process in plant treating domestic waste water from Harahan, La.; plant performance was evaluated by examining coliform reduction, aeration tank oxygenation resulting from two air-flow rates, and overall BOD and suspended solids removal efficiencies (EI 1968)
Sibiryakov, M A SANITARNAYA KHARSKTERISTIKA, ETC
(Sanitary Characteristics of Reservoirs) Kizucheniyu kislorodnogo rezhima vodoemov Sb (Towards the analysis of the oxygen regime of reservoirs Coli)
Trudy AMN SSSR v 10 1951 p 14-43 In Russian
Sideman, S Hortacsu, 0 Fulton, J W MASS TRANSFER IN GAS-LIQUID CONTACTING SYSTEMS lnd and Eng Chern v 48 n 7 Jul1966 p 32-47
Available studies on mass transfer in gas-liquid contacting systems have been critically reviewed; primary weakness in these studies is fact that their correlations are limited to their particular pieces of equipment and ranges of operating conditions; therefore, attempt has been made to organize information into general framework in order to give better insight and understanding to subject; ranges of applicability of these studies have been pointed out, and general correlations have been suggested. 54 refs (EI 1967)
Simonsen, R N AIR FLOTATION DEOILS SOHIO EFFLUENT Oil and Gas J v 60 n 21 May 21 1962 p 146-148 152-154
Air flotation in combination with chemical flocculation cuts oil in effluent to less than 10 ppm; at one location packaged unit of total pressurization type guards plant effluent discharging to city sewer; at another refinery two-stage API separator was redesigned to provide air flotation unit of recycle type with 3,000 gpm capacity; third installation was made to prevent visible oil films on receiving stream passing through residential and rural areas (EI 1962)
Simonsen, R N REMOVE OIL BY AIR FLOTATION Hydrocarbon Processing and Petroleum Refineries v 41 n 5 May 1962 p 145-148
Three refineries have dissolved air flotation units of different types in operation; air flotation was selected over more conventional flocculation and sedimentation process for secondary oil removal because of anticipated smaller equipment sizes and costs, ability to handle varying feed without upsets, and easier sludge disposal; principles of air flotation; conversion of API-type converter to air flotation process; summary of performance (EI 1962)
101
BASIC STUDIES streams reaeration
EQUIPMENT waste treatment
BASIC STUDIES reservoirs
GENERAL reviews
EQUIPMENT mise uses
EQUIPMENT mise uses
S-14
S-15
S-16
S-17
S-18
S-19
S-Continued
Sinkoff, M D Geilker, CD Rennerfelt, J G AN ANALOG COMPUTER FOR THE OXYGEN SAG CURVE Proc ASCE v 84 n SA6 Nov 1958
Presents a theory for application of the analog computer to stream pollution problems
Smirnov, D N Kuz'min, A A Saiti, R N AUTOMATIC CONTROL OF THE AMOUNT OF DISSOLVED
OXYGEN IN WASTE WATERS Vodosnabzh Sanit Tekh v 5 1960 p 18-24
The apparatus employs the polarographic method and its probe consists of two solid electrodes, Au and Zn, protected by the gas-permeable membranes. The electroctrolyte between electrodes is 0.1 N NaOAc solution with agar agar. Diffusion of oxygen through the membrane causes depolarization of the indicating electrolyte and flow of current in the circuit of the cell. The apparatus can be used in the laboratory as well as under industrial conditions In Russian
Smith, A SURFACE AERATORS SPIN TO COMEBACK Water and Wastes Eng v 3 n 12 Dec 1966 p 54-56
Economical method for mixing and furnishing oxygen to wastes in tanks and lagoons; selection of aeration units should not be based on oxygen transfer alone; mixing and tank geometry must also be considered; example of activated sludge plant designed to operate at 15° C with 2 mg of dissolved oxygen per liter of mixed liquor; oxygen requirements are 100 lb/hr (EI 1967)
Smith, A R TESTING AND RATING SURFACE AERATORS Water and Sewage Works 1964 P R264-268.
Smith, H L BABINE LAKE BUBBLER SYSTEM Eng J v 51 n 3 Mar 1968 p 39-45
Adaption of air bubbling system for melting lake ice in winter is described; system was installed toward north end of lake in British Columbia; air required is supplied by unperforated galvanized steel pipe to drop-off point of western bench; distance is some 1,595 ft from west shore, at which point depth is 161 ft; connection between two 50-ft lengths of polyethylene pipe is made with galvanized steel insert coupling to which pipe ends are clamped with two stainless steel straps; lake area is subjected to winter conditions with lowest ambient temperature of -47° F, and average winter. snowfall amounted to 87 in. EIC-68-CIV 3 (EI1968)
Smutek, Rados Rudis, Miroslav DIFFUSION OF OXYGEN THROUGH THE FREE SURFACE OF A TURBULENT OPEN CHANNEL FLOW
(Ceskcslov. Akad. Ved, Prague, Czech.) Acta Tech (Prague) v 14 ri 3 1969 p 326-351
The transfer rate, K, of oxygen from an oxygen-nitrogen mixture into water flowing under turbulent conditions was studied to determine the mechanism of transfer of oxygen from air into water. To prevent desorption, Na2S03 was used to bond the oxygen in the water through formation of Na2S04. At 18° and surface-active agent (SAA) concentrations of 0.1 mg/1, the
102
BASIC STUDIES streams theoretical
DO ANALYSIS instrumentation
EQUIPMENT waste treatment mechanical aerators
EQUIPMENT mechanical perators
EQUIPMENT reservoirs diffusers mise uses
BASIC STUDIES streams experimental reaeration
S-20
S-21
S-22
S-23
S-Continued
mass-transfer coefficient for oxygen, KL, was Au0.683, where u is the flow velocity and A is a coefficient depending on the surface roughness of the channel. For a smooth surface, A = 0.00396 and increases with increasing roughness. At low SAA level, KL is related to u and to the SAA concentrations b,y KL =-' 0.00214 u0.76cSAA -0.15. There is a limiting concentration, however, beyond which no further effect exists. It was not possible to construct a physical model for the transfer process In Czech
Sooky, Attila A LONGITUDINAL DISPERSION IN OPEN CHANNELS Proc ASCE v 95 n HY 4 Jul 1969 p 1327-1346
The effects of cross-sectional geometry and velocity distribution on the dispersion process in straight, uniform open channels with large width-to-depth ratio are investigated. The method of investigation follows Taylor's approach; results apply after the elapse of an initial period during which a constant dispersion coefficient has developed. Under the assumed conditions, the longitudinal dispersion coefficient can be described by a general expression in which the hydraulic radius and the shear velocity are variables. Dispersion varies significantly with cross-sectional shape, width-to-hydraulic radius ratio, and the Reynolds number. The calculated values and pattern of variation are compared to available data for open channels with irregular cross section. 28 refs
Speece, R E STREAM OXYGENATION WITH THE U-TUBE Proc 7th Annual Sanitary and Water Resources Engineering Conf Vanderbilt Univ
May 1968
Speece, R E THE USE OF PURE OXYGEN IN RIVER AND
IMPOUNDMENT AERATION Paper 24th Purdue I nd Waste Conf May 1969
In many situations, using pure oxygen offers an economically competitive alternative for artificial aeration of rivers and impoundments. Proper design of the oxygen injection system can make using pure oxygen very advantageous and achieve efficient absorption. The judicious selection of an oxygen injection system can result in side benefits and flexibility not possible when using air. The application of pure oxygen is economically competitive with air when attempting to aerate water that is about 50 percent saturated with dissolved oxygen or when attempting to achieve near-saturation concentrations in the effluent. Nitrogen concentration can present a serious problem when fish are involved, but can be alleviated by using pure oxygen
Speece, R E U-TUBE STREAM RE-AERATION Public Works NY v 100 n 8 1969 pp 111-113
The uses of the U-tube system for aerating streams, its operating characteristics, and a modification using dispersed air injection (see also Wat. Pollut. Abstr., 1969, 42, Abstr. No~ 894) are discussed, and arrangements for U-tube aeration at a low dam using the cascade to entrain air and at the discharge point of a stratified reservoir to aerate the waters of the hypolimnion are described
103
BASIC STUDIES streams experimental
EQUIPMENT streams U-tubes
EQUIPMENT streams reservoirs molecular oxygen
EQUIPMENT streams U-tubes
S-24
S-25
S-26
S-27
S-Continued
Speece, Richard E Adams, Jack L U-TUBE OXYGENATION OPERATING CHARACTERISTICS N.Mex. State U Eng Exp Sta Tech Report No. 45 Las Cruces May 1968
Gives oxygen transfer equation and advantages of U-tube aeration. Results are given for an experimental U-tube system; the system favors depths of 40ft or more, nominal water velocities greater than 6 fps, and minimum diffuser depths in most cases where air is injected
Speece, Richard E Adams, Jack L Wooldridge, Carolyn B U-TUBE AERATION OPERATING CHARACTERISTICS Proc ASCE v 95 n SA 3 Jun 1969 p 563-574
A modification of U-tube aeration, using low-pressure air injection, was studied on a pilot scale. The pilot U-tube system was made of 4-inch-diameter pipe. Deptbs of 10, 20, 30, and 40 ft were studied at flow rates up to about 300 gpm. Air injection rates of 5, 10, 15, and 20 percent at different depths were studied. The data were subjected to dimensional analysis and equations were derived for predicting prototype results. The effects of air injection depth, U-tube depth, and nominal water velocity on oxygen transfer economy were evaluated. The results show that water containing zero DO can be 100 percent saturated after one pass through a 40-ft-deep U-tube with 20 percent air injection. In the process of completely saturating water, the U-tube oxygen transfer economy (#02/HP-hr) is about the same as conventional aeration systems transferring oxygen to water with zero DO
Speece, R E Orosco, R DESIGN OF U-TUBE AERATION SYSTEMS Proc ASCE v 96 n SA 3 Jun 1970
Four independent parameters were studied in the design of U-tube aeration systems: (1) Air-water ratio; (2) inlet dissolved oxygen concentration; (3) depth; and (4) water velocity. Each different combination of parameters will result in different capital and operating costs. Outlet dissolved oxygen concentration is reported in this study for the following range of independent parameters: ( 1) Air-water ratio= 5 to 25 percent; (2) inlet dissolved oxygen = 0 to 100 percent saturation; (3) depth·= 20 to 40ft; and (4) water velocity= 3.6 to 9.2 ft per sec. A computer model of the gas transfer equation, adapted to the U-tube aerator was used to evaluate the reaeration coefficient, K2. Transfer of gases other than oxygen is analyzed.
Stalmann, V DIE BSK-TURBINE-EIN NEUES HOCHLEISTUNGS
BELUEFTUNGSSYSGEM DER ABWASSERTECHNIK Gas- u Wasserfach v 106 n 22 Jun 4 1965 p 613-617
BSK turbine, new and highly efficient aeration system for sewage treatment; performance of economic and improved oxygen entrainment of new, Swiss-designed, aerator are presented in form of tabulated data and graphs on sewage and clean water tests; applicability for smaller plants is pointed out; special features are simplicity of installation obviating complicated blower syst~m, no clogging assuring plant safety, extensive foam destruction and easy adaptability to changing and sudden rise in contamination and density level of sewage to be treated In German ( E I 1966)
104
EQUIPMENT U-tubes
EQUIPMENT U-tubes
EQUIPMENT U-tubes
EQUIPMENT waste treatment mechanical
aerators
S-28
S-29
S-30
S-31
S-32
S-33
S-Continued
Stefan, M J et al UBER DIE DIFFUSION DER KOHLENSAURE DURCH WASSER UNO ALKOHOL
Class II Vienna 1878 p 371 In German
Stefan, M Jet al UBER DIE DIFFUSION DER FLUSSIGKEITEN v 79 1879 p 161
This and preceding reference show development of solution to Fick's second law of diffu~ion In German
Steller, K ZASYSANIE POWIETRZA PRZEZ TURBINE WODNA Polska Adademia Nauk-Prace lnstytutu Maszyn Przeplywowych n 33 1966
p 49-63 Air suction by water turbine; results of experiments with model turbines inducting air by leakage and from free surface vortices confirm adverse effect of air contained in water on turbine characteristics; presence of air causes not only drop of efficiency and flow disturbances in rotor and in suction pipe, but also deformation of power characteristics of tested model; vortex and water hammer phenomena observed prove that presence of air influences rise and development of cavitation; observations may be useful for quantitative evaluation of hydraulic losses due to definite amount of air inducted into water flowing through turbine In Polish ( El 1967)
Storch, 8 THE DESIGN, CONSTRUCTION, AND OPERATION OF
EXTENDED AERATION PLANTS Water Pollution Control London v 68 1969 p 40-50
The author discusses the design, construction, and operation of extended aeration plants with diffused-air aeration, and stresses the importance of ease of maintenance and control to ensure that the plant will be operated correctly (WPA 1383 Jul 1969)
Stratton, F E NITRIFICATION EFFECTS ON OXYGEN RESOURCES IN
STREAMS Dissertation Abstracts v B27 1967 p 3551 Chern Abstracts v 67 1967 p 7997
Stratton, F E McCarty, P L PREDICTION OF NITRIFICATION EFFECTS ON DISSOLVED
OXYGEN BALANCE OF STREAMS Environmental Sci and Tech v 1 n 5 May 1967 p 405-410
Method for predictinn of dissolved oxygen demand due to biochemical oxidation of inorganic reduced nitrogen compounds utilizes digital computer to estimate nitrifying rate parameters for two-step nitrification process, including kinetic rate constants and initial concentration of nitrifying bacteria; variation of rate constants with temperature is discussed and method for evaluating decay of viable nitriteoxidizing bacteria in absence of its specific substrate is presented; examples comparing predicted and measured nitrogen changes are shown ( E I 1967)
105
BASIC STUDIES reaeration
BASIC STUDIES reaeration
EQUIPMENT turbine injection
EQUIPMENT waste treatment diffusers
BASIC STUDIES streams oxidation
BASIC STUDIES streams oxidation
S-34
S-35
S-36
S-37
S-38
S-39
S-40
S-41
S-Continued
Streeter, H W MEASURES OF NATURAL OXIDATION IN POLLUTED
STREAMS II THE REAERATION FACTOR AND OXYGEN BALANCE
Sewage Works J v 7 n 3 May 1935 p 534
Streeter, H W Wright; C T Kehr, R W MEASURES OF NATURAL OXIDATION IN POLLUTED STREAMS, Ill, AN EXPERIMENTAL STUDY OF ATMOSPHERIC REAERATION UNDER STREAM FLOW CONDITIONS
Sewage Works J March 1936 p 282
Streeter, H W THE OXYGEN SAG AND DISSOLVED OXYGEN
RELATIONSHIPS IN STREAMS Oxygen Relationships in Streams Tech Report No. W-58-2 Taft Sanitary
Eng Center 1958
Streeter, H W Phelps, E B A STUDY OF THE POLLUTION AND NATURAL
PURIFICATION OF THE OHIO RIVER Ill FACTORS CONCERNED IN THE PHENOMENA OF OXIDATION AND REAERATION
Public Health Bull No. 146 US Public Health Service Washington D C 1925 Reprinted 1958
Streif, Abraham COMPRESSED AIR VERSUS DROUGHT Compressed Air Magazine v 60 1955 p 232
Proposes using compressed air for artificial turnover to reduce summer evaporation losses by bringing cold bottom water to the surface
Sullivan, S L Jr Hardy, B W Holland, CD FORMATION OF AIR BUBBLES AT ORIFICES SUBMERGED
BENEATH LIQUIDS A I Ch E J v 1 0 n 6 Nov 1964 p 848-854
Air bubbles were formed at orifices submerged beneath each of 14 liquids, at various angles of inclination; effect of liquid velocity past horizontal, submerged orifice on formation of air bubbles was determined; bubble formation was correlated with physical variables of system by use of Newton's second law of motion; several chemical processes depend upon contacting liquid as continuous phase with gas as dispersed phase (EI 1966)
Susag, R H Polta, R C Schroepfer, G J MECHANICAL SURFACE AERATION OF RECEIVING WATERS J Water Pollution Control Federation Jan 1966
Susag, Russell H Robins, Maurice L Schroepfer, George J IMPROVING RIVER AERATION AT AN UNDERFLOW DAM Proc ASCE v 93 n SA 6 Dec 1967 p 133-144
The aeration occurring in flow through dams can be a significant contribution to the dissolved oxygen resources of a river receiving the oxygen consuming
106
BASIC STUDIES streams experimental reaeration
BASIC STUDIES streams experimental: reaeration
BASIC STUDIES streams reaeration oxidation
BASIC STUDIES streams reaeration oxidation
EQUIPMENT· reservoirs diffusers mise uses
BASIC STUDIES bubbles experimental
EQUIPMENT streams mechanical aerators
EQUIPMENT streams cascades
S-42
S-43
S-44
S-45
S-Continued
organic material of waste waters. Changes in physical or operational characteristics of a dam can affect the rate of aeration. The aeration rate at Lock and Dam No. 2 on the Mississippi River near Hastings, Minn., had been reduced by a factor of three by an increase in tailwater elevation resulting from the construction of another dam downstream. Conversion of the underflow gate structure to an overflow condition by the installation of bulkheads and increasing downstream turbulence almost restored the lost aeration capacity. This study demonstrates that aeration at dams can be improved through changes in operation and indicates that the contribution of dams to river-dissolved oxygen resources should be included in the consideration of dam design and operation
Symons, J M WATER QUALITY BEHAVIOR IN RESERVOIRS Public Health Service Bureau of Water Hygiene Cincinnati Ohio 1969
Symons, J M Irwin, W H Robinson, E L Robeck, G G IMPOUNDMENT DESTRATIFICATION FOR RAW WATER QUALITY CONTROL USING EITHER MECHANICAL- OR DIFFUSED-AIR PUMPING
J American Water Works Assoc Oct 1967 Two methods of artifically destratifying lakes and reservoirs are compared; comparisons are based on water quality improvement and hydraulic performance; results of experiments showed that mechanical- and diffused-air pumping broke up thermal stratification patterns in study lake successfully and improved water quality; dissolved oxygen was added to water and sulfides, reduced iron and manganese were oxidized; although some nitrogen and phosphorous was transported to surface layers during mixing, excessive algal growths did not develop in either case. 19 refs
Symons, J M Robeck, G G IMPOUNDMENT RESEARCH-1, 2 Water and Wastes Eng (formerly Water Works and Wastes Eng) v 3 n 1, 2
Jan 1966 p 42-44; Feb 1966 p 66-68 Results of study conducted on streamflow regulation projects using method of water quality control in which good-quality stored water is added to stream at times of deteriorating stream water quality; experimental equipment used in studies is reported; studies include artificial destratification and biological transformation of nitrogen. 22 refs (EI 1966)
Symons, J M Weibel, S R Robeck, G G INFLUENCE OF IMPOUNDMENTS ON WATER QUALITY US Public Health Service-Environmental Health Ser Water Supply and Pollution
Control-Pub! 999-WP-18 Oct 1964 Since streamflow regulation is considered as method of water quality control in impoundments, changes in water quality that occur durjng storage in given environment must be understood and predicted; to aid such study and further research needs, selected references in sanitary engineering and limnology are reviewed with additional section on impoundment releases on downstream water quality as well as operations research for water quality management. 147 refs ( El 1966)
107
BA~IC STUDIES reservoirs
EQUIPMENT reservoirs diffusers
BASIC STUDIES reservoirs
BASIC STUDIES reservoirs
S-46
S-47
S-48
S-49
S-Continued
Symons, James M Irwin, William H Clark, Robert M Robeck, Gordon G MANAGEMENT AND MEASUREMENT OF DO IN IMPOUNDMENTS Proc ASCE v 93 n SA 6 proc paper 5688 Dec 1967 p 181-209
A basis for the comparison of various mechanical devices used for artifically destratifying impoundments by calculating their hydraulic performance based on impoundment stability is recommended. Three problems with this calculation are discussed to avoid misinterpretation, influence of size and geometry on stability, natural changes in stability with time, and the basic hydraulic inefficiency of spring mixing if cold water is raised. Also, a mathematical model is developed for studying. the DO budget in impoundments. A solution to the model is presented, using specially designed DO probe equipment. Finally, data are presented on the destratification of a 2,930-acre-ft impoundment in northern Kentucky by pumping. The hydraulic performance of the pump is calculated and the influence of the mixing on the reduced substances and the DO resources in the impoundment is shown. The most favorable time for destratification is also discussed. A bibliography on artificial destratification is included
Symons, J M Irwin, W A Robeck, G G VERBESSERUNG DER WASSEROUALITAET VON TALSPERREN
DURCH KUENSTLICHE UMSCHICHTUNG Vom Wasser v 34 1967 p 158-174
Improvement of reservoir water quality by artificial destratification; commercial-scale experiments on two impoundments, one under study and other undisturbed for comparison purposes, showed high improvement of water quality, due to water destratification by means of pumping and aeration; curves of temperature, oxygen concentration, sulfide and Mn ions concentrations, and phytoplankton, concentration vs time (24 wk) were plotted for depth from 1.5 to 15 m; oxygenation capacity factor and destratification efficiency were used to compute· capacity of aeration installation. 15 refs. In German ( El 1968)
Symons, James M Irwin, William H Robeck, Gordon G IMPOUNDMENT WATER QUALITY CHANGES CAUSED BY
MIXING Federal Water Pollution Control Admin Cincinnati Apr 1966
Mechanical pumping was used to artifically destratify a 2,380-acre-ft lake in northern Kentucky. The pump drew water from the bottom and discharged it at the surface. Analysis of samples taken weekly, from May 14 to October 29, 1965, throughout the depth of the lake, showed the influence of mixing on water quality. A nearby lake of nearly equal volume, sampled similarly, was the control. Results showed a warming and oxygenating of the lower layers of the test lake that resulted in the precipitation of manganese and the oxidation of sulfide. Mixing neither increased the concentration of any nitrogen form, or the total hydrolyzable phosphorous, nor decreased the clarity in the surface. There was no increase in algal densities. Some data on work requirements and efficiencies are also given
Symons, J M Carswell, J K Robeck, G G MIXING OF WATER SUPPLY RESERVOIRS FOR QUALITY
CONTROL J American Water Works Assoc v 62 n 5 May 1970 p 322-334
Describes test destratification of relatively small reservoirs (up to 2,900 acre-ft) using either mechanical or diffused air pumping. Dissolved oxygen in
108
BASIC STUDIES reservoirs EQUIPMENT reservoirs diffusers pumps
BASIC STUD I'ES reservoirs
BASIC STUDIES reservoirs
EQUIPMENT reservoirs diffusers
S~Continued
the hypolimnion was increased and associated water quality problems were alleviated. Results from one of the test lakes showed reoxygenation efficiencies of 0.7 lb/kwhr for mechanical pumping and 1.7 lb/kwhr for diffused air pumping. Guidelines are given for design and equipment performance evaluation. Includes a summary of water purvey.or experience in destratification at 17 reservoirs.
109
T-1
T-2
T-3
T-4
T-5
T
Takahashi, T Fan, L T SEVERAL DIFFERENT GAS-LIQUID CONTACTORS
UTILIZING CENTRIFUGAL FORCE Kans State U lnst for Syste11_1s Design and Optimization Report No. 10
Dec 19 1968 Manhattan Kans Describes the features of several centrifugal contactors; these contactors are coming into use but as yet there is no literature on design features and fundamental studies. Centrifugal contactors are expected to be widely used because of favorable mass-transfer characteristics
Tarassov, Victor J Perlis, Harlan J Davidson, Burton OPTIMIZATION OF A CLASS OF RIVER AERATION
PROBLEMS BY THE USE OF MULTIVARIABLE DISTRIBUTED PARAMETER CONTROL THEORY
Water Resources Res v 5 n 3 Jun 1969 p 563-573 Mathematical programming methods applied to water pollution problems have been highly successful, especially in cases where hypothetical models were used. In many applications, linear programming, dynamic programming, or Pontryagin's Maximum Principle methods have been demonstrated, using steady-state Streeter-Phelps system equations at some stage in the optimization study. The application of the Sirazetdinov-Tarassov-Perlis theory of optimal control to the artificial instream aeration problem in polluted rivers is examined. The main concern of the study is to show how artificial instream aeration can be controlled, minimizing the relative cost of operation for several competing design criteria. The economic aspects of cost minimization of this process have important theoretical implications and potential applications to specific water pollution problems. 19 refs
Technical Practice Committee Subcommittee on Aeration in Wastewater Treatment
AERATION IN WASTEWATER TREATMENT -MOP 5 J Water Pollution Control Federation v 41 n 11 Nov 1969 p 1863 v 41 n 12
Dec 1969 p 2026 "Aeration in Wastewater Treatment" is the revised edition of the original Manual of Practice No. 5, "Air Diffusion in Sewage Works," published in 1952. The manual is intended to provide designers, operators, and maintenance personnel of wastewater treatment facilities with the fundamental theory and operational aspects of aeration. First and second installments
Technical Practice Committee Subcommittee on Aeration in Wastewater Treatment
AERATION IN WASTEWATER TREATMENT -MOP 5 J Water Pollution Control Federation v 42 n 1 Jan 1970 p 51
Third of three installments. Discussion of operation and maintenance of aeration systems, with emphasis on diffusers. Includes short discussion of air blowers
Teerink, John R Martin, Cecil V ARTIFICIAL DESTRATIFICATION IN RESERVOIRS OF THE
CALIFORNIA STATE WATER PROJECT J American Water Works Assoc v 61 n 9 Sep 1969 p 436-440
Destratification and aeration in Calif. reservoirs are accomplished by air injection and multiple-level outlet structures. Mixing returns nutrients to the
110
EQUIPMENT mise equipment
BASIC STUDIES. streams theoretical reaeration
EQUIPMENT waste treatment
EQUIPMENT waste treatment
EQUIPfl-'IENT reservoirs diffusers economics
T•8
T~9
T-10
T -Co~tim.led
photosynthetic zone for use by organisms, and oxidizes iron and manganese. The effects may be beneficial or detrimental to intended water uses. Evaporation is usually reduced because surface water temperatures are lowered Dissolved oxygen is increased. Because artificial destratification can produce both benefits and detriments, a study should be made of priority of uses and the effects of mixing, and cost-benefit analyses should be made, placing a value on the various quality changes related to mixing. 16 refs (Knapp-USGS) W69-09883
Thackston, E L APPLICATIONS OF ANALOG COMPUTERS IN SANITARY
ENGINEERING Proc of the 3rd Annual Workshop American Assoc of Professors in Sanitary Eng Jun 1968 (Editor)
Thackston, E L discussion of CONTROL OF IMPOUNDMENT WATER QUALITY
BY ENGINEERING METHODS by J. M. Symons, W. H. Irwin, G. G. Robeck ASCE Specialty Conf on Current Res into the Effects of Reservoirs on Water
Quality Portland Jan 22-24 1968
Thackston, E L discussion of MANAGEMENT AND MEASUREMENT OF D.O.
IN IMPOUNDMENTS by J. M. Symons, W. H. Irwin, R. M. Clark and G. G. Robeck
Proc ASCE v 94 n SA 4 Aug 1968 p 748-752
Thackston, Edward L Hays, James R Krenke!, Peter A LEAST SQUARES ESTIMATION OF MIXING COEFFICIENTS Proc ASCE v 93 n SA 3 Jun 1967 proc paper 5288 p 47-58
The principle of least squares estimation of nonlinear parameters as a general tool in mathematical modeling can be shown to be applicable to many common problems in sanitary engineering.- A digital computer program for accomplishing this procedure is explained, and the results are illustrated for the example of estimating mixing coefficients and mean travel times for measured time- concentration curves. A critical examination of existing estimation procedures shows them to be inaccurate and unreliable. The results of comparative fit of several methods to several hundred curves are presented. If a digital computer is not available, a simple, quick, trial-and-error procedure-outlined in the paper-can be used to produce results more reliable than those given by presently used methods
Thackston, E L Krenkel, P A discussion of BOD AND OXYGEN RELATIONSHIPS IN
STREAMS by William E .. Dobbins Proc ASCE v 91 n SA 1 Feb 1965 proc paper 3949 p 84-88
Thackston, E L Krenkel, P A LONGITUDINAL MIXING AND REAERATION IN NATURAL STREAMS
Tech Report No.7 in Sanitary and Water Resources Eng Vanderbilt U Nashville T enn 1966
111
GENERAL
BASIC STUDIES reservoirs
BASIC STUDIES reservoirs
BASIC STUDIES streams
BASIC STUDIES streams reaeration
BASIC STUDIES streams reaeration
T-12
T-13
T-14
T-15
T-16
T -Continued
Thackston, E L Krenke!, P A LONGITUDINAL MIXING IN NATURAL STREAMS Proc ASCE v 93 n SA 5 Oct 1967 p 67-90
Various models used to describe or predict longitudinal mixing coefficients are examined and the conditions under which they are expected to a'pply are elucidated. Several hundred coefficients, both in laboratory flumes and natural streams, were measured under two-dimensional, uniform-flow conditions. The coefficients measured in natural streams are shown to follow equations derived from flume data. The influence of dead zones in the stream on mixing is examined, and it is shown that measured coefficients are much closer to predicted values when the influence of mixing due to the dead zones is separated by the use of a new mixing model
Thackston, Edward L Krenke!, Peter A REAERATION PREDICTION IN NATURAL STREAMS Proc ASCE v 95 n SA 1 Feb 1969 p 65-94
Reviews the predictive equations of O'Connor-Dobbins, Krenke!, Dobbins, Kalinske, and Churchill; proposes a new formula and gives field data for correlation
Thackston, Edward L Krenkel, Peter A TURBULENT DIFFUSION AND REAERATION Proc 14th So. Water Resources and Pollution Control Conf held at U of N C
Chapel Hill N C Apr 1965 p 197-206
Thackston, Edward L Speece, R E REVIEW OF SUPPLEMENTAL REAERATION OF FLOWING STREAMS
J Water Pollution Control Federation v 38 n 10 Oct 1966 p 1614-1622 Diffused air, turbine aeration, weirs, surface aeration, pressure injection, and U-tubes are among methods of providing supplemental aeration in flowing streams; weirs are quite efficient and inexpensive; turbine aeration also appears to be inexpensive, whereas diffused-air and surface aeration are far more costly for same amount of oxygen transfer; pressure injection seems, from its limited use thus far, to be efficient; very effective U-tube process may be applicable to small streams. 20 refs
Thackston, Edward L Speece, R E SUPPLEMENTAL REAERATION OF LAKES AND RESERVOIRS J American Water Works Assoc v 58 n 10 Oct 1966 p 1317-1324
Supplemental aeration and mixing of water in lakes and reservoirs is complicated by stratification and the tremendous volume of water to be moved. A method of oxygenation must provide for distributing oxygen throughout the impounded water, or the water must be mixed to bring it into contact with oxygen at the surface. Most methods of supplemental aeration of impounded waters rely on mixing alone and do not attempt to.add oxygen directly. Mixing brings the oxygen-deficient hypolimnion into contact with the atmosphere where it absorbs oxygen and also breaks up the temperature stratification, enabling natural wind forces to cause further mixing action with resulting distribution of oxygen throughoutthe entire depth of water. Once stratification is broken, continuous pumping is unnecessary; usually intermittent operation will cause complete mixing throughout the season. The most successful attempts to destroy stratification have used compressed air. One of the more promising recent developments is the aerohydraulic gun,
112
BASIC STUDIES streams
BASIC STUDIES streams experimental reaeration
BASIC STUDIES streams reaeration
GENERAL reviews EQUIPMENT streams diffusers turbine injection cascades mechanical
aerators pressure injection U-tubes
GENERAL reviews EQUIPMENT reservoirs diffusers hydraulic guns
T-17
T-18
T-19
T-20
T -Continued
or bubble gun, which shoots air bubbles to the surface from underwater tubes. Rising bubbles shatter as they leave the tube mouth and entrain considerably more water than actually flows through the tube. Other techniques for reaerating impounded water are discussed
Thayer, Richard P Krutchkoff, Richard G STOCHASTIC MODEL FOR BOD AND DO IN STREAMS Proc ASCE v 93 n SA 3 Jun 1967 p 59-72
A stochastic model for pollution and dissolved oxygen in streams is obtained. Given the stream parameters and the initial conditions, the model predicts not only the mean amounts of pollution and dissolved oxygen at any point downstream, but also their variability in time. One can determine the proportion of the time that pollution is above any given concentration or that dissolved oxygen is below any given concentration. The theoretical results are tested by comparing them with controlled laboratory experiments and with data from the Sacramento River. It is observed that the means of both pollution and dissolved oxygen follow the equations already obtained by Dobbins ("BOD and Oxygen Relationships in Streams," J of the Sanitary Eng Div, ASCE v 90 n SA 3 Jun 1964 proc paper 3949 p 53). A new and unexpected observation is that the greatest variability in dissolved oxygen occurs at the sag, where it is most critical
Thomman, Robert V MATHEMATICAL MODEL FOR DISSOLVED OXYGEN Proc ASCE v 89 n SA 5 Oct 1963 p 1-30 Discussion: Alex N Diachishin SA 3:Jun 64: 137:3935; Donald J O'Connor and
Dominic Di Toro SA 6:Dec 64:117:4171 Closure: SA 6:Dec 64:122:4171
The basic concepts of systems analysis and its application to DO are presented. The mathematical model is developed by viewing a particular body of water such as an estuary as composed of a number of finite segments each comprising a "system" in the classical mathematical sense. A dissolved oxygen balance equation can then be written for each system. A linear systems analysis technique is then used and the DO response resulting from the input forcing functions are derived
Thomann, R V RECENT RESULTS FROM MATHEMATICAL MODEL OF WATER POLLUTION CONTROL IN DELAWARE ESTUARY
Water Resources Res v 1 n 3 Third Quarter 1966 p 349-359 Basic concepts of systems analysis and optimum (least-cost) water pollution control are presented; equations utilized to describe time and space variability of dissolved oxygen are presented in systems analysis context, and their usefulness in this form is discussed; application of mathematical model to control of dissolved oxygen in Delaware Estuary is given; recent computer solutions are illustrated, and sensitivity of least-cost dissolved oxygen improvement solutions to rate of atmospheric reaeration is presented ( El 1966)
Thomann, R V TIME-SERIES ANALYSIS OF WATER-QUALITY DATA Proc ASCE v 93 n SA 1 Feb 1967 p 1-23
The basic concepts of Fourier and power spectrum analyses are presented in terms of their application to dissolved oxygen and temperature data of the
113
BASIC STUDIES streams theoretical reaeration oxidation
BASIC STUDIES theoretical
BASIC STUDIES estuaries theoretical
BASIC STUD I ES estuaries experimental
T-21
T-22
T-23
T-24
T-26
T -Continued
Delaware Estuary. The results of Fourier analyses.computations performed on hourly data from water-quality monitoring stations are presented. For temperature, more than 92 percent of the total variance is accounted for by the 365-day periodicity. For dissolved oxygen, more than 90 percent of the total variance is accounted for by the annual periodicity and the next four higher harmonics (semi-annual; tri-annual, etc.). The dissolved oxygen variability remaining after removal of the principal Fourier components was found to be approximately normally distributed with an average standard deviation of 0.85 mg per I. Power spectrum analyses of the 24-hr averaged DO residual seconds indicated a peak in the region of 30 to 60 days and for temperature a peak is dominant at 30 days. The analyses all indicate a predominance of low frequency (periods of from 7 days to 1 year and longer) types of phenomena. The implications of the results from a sampling and control point of view are evaluated
Thomas, HA Jr THE "SLOPE" METHOD OF EVALUATING THE CONSTANTS
OF THE RIRST-STAGE BIOCHEMICAL OXYGEN DEMAND CURVE
Sewage Works J v 9 n 3 May 1937 p 425
Thomas, lvor E DISPERSION IN OPEN CHANNEL FLOW PhD Thesis Northwestern U Evanston Ill 1958
Toei, Ryozo Matsuno, Ryuichi Nishitani, Keiichi Hayashi, Hideo I mamoto, Tsunehiko
GAS INTERCHANGE BETWEEN BUBBLE PHASE AND CONTINUOUS PHASE IN GAS-SOLID FLUIDIZED BED AT COALESCENCE
Chern Abstracts v 71 1969 p 134 The process of coalescence of bubbles was investigated from the viewpoint of gas interchange (mass transfer) between the bubble phase and the continuous phase. A two-dimensional fluidized bed was used to determine the gas mass-transfer coefficient
Truesdale, G A NEW SOLUBILITY DATA FOR OXYGEN J of Applied Chern v 5 1955
Truesdale, G A Vandyke, K G THE EFFECT OF TEMPERATURE ON THE AERATION
OF FLOWING WATER Water and Waste Treatment J v 7 n 9 May-Jun 1958
Tsivoglou, E C MODERN CONCEPTS OF BOD-DO RELATIONSHIPS Ontario lnd Waste Conf 12th-Proc Jun 1965 p 147-157
Summary of more recent work at Robert A. Taft Sanitary Engineering Center on factors involved in stream self-purification, with particular emphasis on relationship of this work to disposal of industrial effluents; analysis of BOD reaction kinetics, as determined on basis of observed BOD rate curves; it is shown that waste treatment plants designed only on basis of 5-day BOD determination will prove inadequate to meet desired DO objectives in receiving streams ( El 1966)
114
BASIC STUDIES experimental oxidation
BASIC STUDIES streams
BASIC STUDIES bubbles experimental
BASIC STUDIES experimental reaeration
BASIC STUDIES streams experimental reaeration
BASIC STUDIES streams experimental oxidation
T-27
T-28
T-29
T-30
T-31
T-32
T -Continued
Tsivoglou, E C O'Connell, R L Walter, C M Godsil, P J Logsdon, G S TRACER MEASUREMENTS OF ATMOSPHERIC REAERATION-1
LABORATORY STUDIES J Water Pollution Control Federation v 37 n 10 Oct 1965 p 1343-1362
Evaluates atmospheric reaeration rates in turbulent systems by laboratory experiments using chemically inert radioactive tracer gases; results show Kr 85 and Rn 222 are suitable tracers for oxygen gas. Tests indicate reaeration in turbulent systems takes place in two separate consecutive steps-diffusion of gas across the liquid-air interface, and subsequent mixing and dispersion of the dissolved gas throughout the main body of water
Tisvoglou, E C TRACER MEASUREMENT OF STREAM REAERATION Federal Water Pollution Control Admin Div of Tech Services US Dept Interior Washington D C 1967
Reports laboratory and field trials on tracer measurement of stream reaeration
Tsivoglou, E C Cohen, J B Shearer, S D Godsil, P J TRACER MEASUREMENT OF STREAM REAERATION-11
FIELD STUDIES J Water Pollution Control Federation Washington D C 20016 v 40 n 2 pt 1
Feb 1968 p 285-305 New method for accurate and independent direct measurement of gas transfer and reaeration capacity of natural streams is presented; fluorescent dye, dispersion indicator (tritium), and gaseous tracer (krypton-85) were released in main flow of Jackson River from Covington to Clifton Forge, Va.; results show that tracer method may be used in polluted or unpolluted rivers, regardless of sludge deposits, algae, and dissolved oxygen levels; method provides predictions in general range of values predicted by previous investigators. 10 refs
Tsivoglou, E C Wallace, J R HYDRAULIC PROPERTIES RELATED TO STREAM REAERATION Georgia lnst of Tech Unnumbered Undated
Tullis, J P Skinner, M M REDUCING CAVITATION IN VALVES Proc ASCE v 94 n HY 6 Nov 1968 p 1475-1488
The variation of cavitation inception, with and without air injection and as a function of valve opening, are reported for a 12-in. ball valve in a 12-in. butterfly valve with water as the test fluid. Air is injected through the valve stem and side ports of the butterfly valve and through side ports in the ball valve. The water supply is approximately 38° F with an air content of about 70 percent of saturation. Air injection into the separation zone below the valves is shown to effectively eliminate or significantly reduce cavitation. (J. F. Lafferty Applied Mechanics Rev v 22 n 11 Nov 1969 rev 8870.)
Tullis, J P Marschner, B W REVIEW OF CAVITATION RESEARCH ON VALVES Proc ASCE v 94 n HY 1 Jan 1968 p 1-16
Critical cavitation indices are presented for 12-in. ball and 12-in. butterfly valve installed in closed conduit system with sudden expansion downstream
115
BASIC STUDIES streams experimental reaeration
BASIC STUDIES streams experimental reaeration
BASIC STUDIES streams
. experimental reaeration
BASIC STUDIES streams experimental reaeration
CAVITATION
CAVITATION
T-33
T-34
T-35
T -Continued
of valves; tests were conducted under normal operating conditions to find effect of injecting air and water at various locations on critical cavitation index; it was found that injecting water into sudden expansion below valves does not affect cavitation; injecting small quantities of air into separation zones below valves materially reduces cavitation intensity and critical cavitation index. 12 refs (EI 1968)
Tyler, R POLLUTED STREAMS CLEARED UP BY AERATION Civil Eng v 16 1946 p 348-349
Tyler, Richard G ACCELERATED REAERATION Sewage Works J v 14 n 4 Jul 1942 p 834-838
This paper contains one of the early proposals for the use of diffusers for supplemental reaeration of streams
Tyler, Richard G STREAM POLLUTION, ACCELERATED REAERATION CiviiEng (London) v 38 Jan 1943 p 7-9
116
EQUIPMENT streams diffusers
EQUIPMENT streams diffusers
EQUIPMENT streams
V-1
v
Vanderhoof, R A
CHANGES IN WASTE ASSIMILATION CAPACITY RESULTING FROM STREAMFLOW REGULATION
US Dept Health Education Welfare Symposium on Streamflow Regulation for Quality Control Public Health Service Pub No 999-WP-30 Jun 1965
Discusses dissolved oxygen changes in a reservoir and the control of waste assimilative capacity downstream by flow augmentation and peaking power discharges
V-2 Van der Kroon, G T M EFFECT OF SUSPENDED COMPOUNDS ON THE RATE OF OXYGEN TRANSFER INTO WATER SOLUTIONS
Vodni Hospodarstvi (Czech) v 6 1968 p 255 THE INFLUENCE OF SUSPENDED SOLIDS ON THE RATE
OF OXYGEN TRANSFER INTO AQUEOUS SOLUTIONS Water Res v 2 1968 p 26
V-3 Van Wijngaarden, L ON GROWTH OF SMALL CAVITATION BUBBLES BY
CONVECTIVE DIFFUSION I nt J Heat and Mass Transfer v 10 n 2 Feb 1967 p 127-134
In calculation of bubble growth due to convective diffusion of gas (mainly air) by B. R. Parkin and R. W. Kermeen, vapor content of bubbles and surface tension were not taken into account; allowance is made for these effects; V. G. Levich's model is advanced for determination of mass flux in bubbles; growth results are compared with Parkin and Kermeen experimental data. 9 refs (EI1967)
V-4 Varma, M M DiGiano, F KINETICS OF OXYGEN UPTAKE BY DEAD ALGAE J Water Pollution Control Federation v 40 n 4 Apr 1968 p 613
V-5 Velz, C J DEOXYGENATION AND REOXYGENATION Trans ASCE v 1 04 1939 p 560
Presents a nomograph for calculating atmospheric reaeration in turbulent systems
V-6 Velz, C J FACTORS INFLUENCING SELF-PURIFICATION AND THEIR
RELATION TO POLLUTION ABATEMENT Sewage Works Journal v 19 n 4 1947
V-7 Velz, C J SIGNIFICANCE OF ORGANIC SLUDGE DEPOSITS Oxygen Relationships in Streams Tech Report W58-2 Robert A. Taft Sanitary
Eng Center U S Public Health Service 1958
V-8 Verduin, Jacob discussion of PHOTOSYNTHESIS AS A FACTOR IN THE
OXYGEN BALANCE OF RESERVOIRS by C.H.J. Hull US Dept Health Education Welfare Symposium on Streamflow Regulation for
Quality Control Public Health Service Pub No. 999-WP-30 Jun 1965 p 91-94
118
BASIC STUDIES
streams reservoirs
BASIC STUDIES experimental reaeration
CAVITATION
BASIC STUDIES experi menta I oxidation
BASIC STUDIES streams reareation oxidation
BASIC STUDIES streams reaeration
BASIC STUDIES streams oxidation
BASIC STUDIES reservoirs photosynthesis
V -Continued
Discusses establishing the ecological relationships in photosynthetic oxygenation rather than applications to sanitary engineering; gives a table showing amount of oxygen derived from natural phytoplankton communities
V-9 Vinberg, G G ZHACHENIE FOTOSINTEZA JLYA OBOGASHCHENIYA VODY
KISLORODOM PRI SAMOOCHISHCHENII ZAGRYAZNENNYKH VOD (Significance of Photosynthesis for Oxygen Enrichment of Water During
Self-purification qf Polluted Waters) Trudy Vsesoyuz Gidrobiol Obshchestva v 6 1955 p 46-69 In Russian
119
BASIC STUDIES photosynthesis
W-1
w
Wagner, H VOITH-FORSCHUNG UNO KONSTRUKTION (Voith-Research and Construction)
v 1 1955 p 1311 In German
W-2 Wagner, H THE ARTIFICIAL AERATION OF HARNESSED STREAMS Special Communications to the German Hydrological Year Book No. 15
Published by the Federal Office for Hydrology Coblenz (1956) In German
W-3 Wagner, H THE ARTIFICIAL AERATION OF CANALIZED RIVERS Bes Mitt Dtsch Gewasserkundlichen J No. 15 1956 Water Pollution Abstracts (Brit) v 30 1957 p 2222 In German
W-4 Wagner, H EXPERIMENTS WITH ARTIFICIAL AERATION OF RIVER WATER
Deutsche Gewasserkundliche Mitteilungen v 2 n 4 1958 p 73-79 Results of aeration experiments at the Poppenweiler Powerplant on the Neckar, 1957 In German
W-5 Walker, J D CROSS-ROLL AERATION ELIMINATES SHORT CIRCUITING Water and Wastes Eng (formerly Water Works and Wastes Eng) v 3 n 1 Jan 1966
p 57-59 Effects of cross-roll aeration method in long-period reaeration processes to eliminate short circuiting so that progressive synthesis will take place and finished sludge will be endogenous before reentry into contact are outlined; how diffusers and air headers are arranged for cross-roll aeration; tests in parallel tanks (EI 1966)
W-6 Wallace, J R Reheis, H F HYDRAULIC PROPERTIES OF THE SOUTH AND FLINT
RIVERS IN THE VICINITY OF ATLANTA, GEORGIA Georgia lnst Techno! Atlanta prepared for the FWPCA Washington D C
Feb 1969 Provides physical data for an investigation on stream reaeration capacity. Physical characteristics of the streams are discharge, flow depth, stream width,- flow velocity, hydraulic radius, wetted perimeter, and stream slope. Predictions of reaeration capacity are made from available predictive models
W-7 Welch, P S LIMNOLOGY, 2D ED McGraw-Hill New York N Y 1952 528 p
W-8 Weston, R F STUDIES IN ENTRAINMENT AERATION J Water Pollution Control Federation v 34 n 4 Apr 1962 p 342-353
Report of work undertaken to better define fundamentals of operation and to determine effects of diameter, blade sizes, number of blades, speed of rotation, submergence, and other variables on horsepower requirements and oxygen transfer (EI 1962)
120
EQUIPMENT streams
EQUIPMENT streams turbine injection
EQUIPMENT streams
EQUIPMENT streams turbine injection
EQUIPMENT waste treatment diffusers
BASIC STUDIES streams experimental reaeration
GENERAL
EQUIPMENT mechanical aerators
W -Continued
W-9 Wezenak, Chester T Gannon, John J EVALUATION OF NITRIFICATION IN STREAMS Proc ASCE v 94 n SA 5 Oct 1968 p 883-895
A simplified procedure for evaluating nitrification progression in a stream is given. Data are presented for the Clinton River between Pontiac and Rochester, Mich. which show rapid inorganic nitrogen oxidation in this section of the river. Graphical and analytical techniques for evaluating nitrification parameters and progression are described
W-10 Whipple, W
W-11
ECONOMICS OF INDUCED RIVER AERATION Chemical Engineering Progress v 65 n 97 1969 (book review)
Whipple, W Jr Coughlan, F P Jr INSTREAM AERATORS FOR POLLUTED RIVERS Reprint 1086 ASCE National Water Resources Meeting Memphis Tenn Jan 26-30 1970
Describes field tests of instream use of mechanical aerator and diffuser. Comparison on basis of transfer efficiency and cost shows mechanical aerator to be superior. Efficiency of mechanical aerator was about 2 to 3 lbs oxygen/hp-hr; diffuser had efficiency about two-thirds that amount. Gives good example of cost analysis
W-12 Whipple, W Jr Hunter, J V Davison, B Dittman, F W Yu, Shaw L IN-STREAM AERATION OF POLLUTED RIVERS Rutgers-The State U New Brunswick N J Water Resources Res lnst
Mechanical and diffuser instream aerators were tested on the Upper Passaic River and proved a practical and economical method of adding dissolved oxygen to polluted streams. The tests were conducted in conjunction with research into photosynthesis, benthal oxygen demand, and mass balance of BOD in that river system. Systems of aerators were designed to provide for meeting water quality objectives of dissolved oxygen and cost estimates made. Alternative costs of meeting the same objectives by means of advanced effluent treatment alone appear to be several times as great. It is concluded that instream aeration may provide a feasible alternative to advanced waste treatment for polluted rivers, as a supplement to secondary waste treatment W69-09555
W-13 White, M T SURFACE AERATION AS SECONDARY TREATMENT SYSTEM Tappi v 48 n 10 Oct 1965 p 128A-132A
Fourteen 60-hp surface aerators were installed as secondary treatment system in one basin of existing two-basin retention lagoon; BOD is reduced by about 36 percent in passing through first basin; overall reduction for summer averaged 88 percent; oxygen transfer efficiency was 3.1 lb/hp-hr at design load range; installation and operating costs (EI 1966)
W-14 Whitman, W G TWO-FILM THEORY OF GAS ABSORPTION Chemical and Metallurgical Engineering v 29 1923 p 146
121
BASIC STUDIES streams experimental oxidation
EQUIPMENT streams economics
EQUIPMENT streams mechanical aerators
diffusers economics
EQUIPMENT streams mechanical aerators
diffusers
EQUIPMENT waste treatment mechanical aerators
BASIC STUDIES theoretical reaeration
W -Continued
W-15 Wiebe, A H THE EFFECT OF DENSITY CURRENTS UPON THE
VERTICAL DISTRIBUTION OF TEMPERATURE AND DISSOLVED OXYGEN IN NORRIS RESERVOIR
J Tenn Academy Sci v 15 1940 p ,301-308
W-16 Wiley, A J Lueck, B F Scott, R H Wisniewski, T F COOPERATIVE STATE-INDUSTRY STREAM STUDIES-LOWER
FOX RIVER, WISCONSIN Sewage and I nd Wastes v 29 Jan 1957 p 76
W-17 ·wiley, A J Lueck, B F Scott, R H Wisniewski, T F COMMERCIAL-SCALE OPERATION OF TURBINE AERATION . ·oN WISCONSIN RIVERS Sewage and I nd Wastes v 32 n 2 Feb 1960 p 186
.. ,-.
W-18 Wiley, A J Lueck, B F TURBINE AERATION AND OTHER METHODS OF
REAERATING STREAMS Tappi v 43 1960 p 241
W-19 Wiley, A J Lueck, B F Scott, R H Wisniewski, T F COMMERCIAL-SCALE STREAM REAERATION J Water Pollution Control Federation v 34 n 4 Apr 1962 p 401
Review of present status of commercial-scale stream aeration as means for accelerating recovery of oxygen-depleted waters and of increasing working capacity of rivers subjected to heavy loadings of biochemical and chemical oxygen demand
W-20 Wiley, A J Parkinson, L Gehm, H W Wisniewski, T F Bartsch, H F RIVER REAERATION Paper Trade J v 124 Mar 20 1947 p 123
A method suggested by Professor Tyler of the University of Wash. consisting of diffusing compressed air beneath the surface of a river which has been polluted for the p'urpose of maintaining minimum levels of dissolved oxygen, has been tried in full scale on a Wis. river. The experimental setup consisted of an aerating station located at a power dam downstream from a suI ph ite mill at a point where a serious sag in dissolved oxygen occurred in the stream during low summer flows. Employing carborundum diffusers with a total area of 319 sq ft set at a depth of about 10ft and fed by a compresser capable of supplying 1,550 cu ft of air per minute at 5 psi it was possible to add to the stream an average of close to 1.5 tons of oxygen per day at a flow of 800 cfs. This together with the immediate satisfaction of a portion of the BOD of the stream water, attributable to aeration, caused a marked movement upstream of the zone of recovery. Hence the process appears to be a useful tool in accelerating the recovery of a polluted stream shortening to a considerable degree the distance of passage required for oxidation of the waste and serves to prevent anerobic conditions and attending nuisance.
Extensive test data collected during operation of the unit are summarized in this paper including biological observations with respect to stream flora and fauna. Recommendations with respect to application, requirements, design, and efficiency are included
122
BASIC STUD.I ES reservoirs
EQUIPMENT: streams turbine injection
EQUIPMENT; streams turbine injection
EQUIPMENTstreams turbine injectJon
EQUIPMENT streams turbine injection
EQUIPMENT streams diffusers
W -Continued
W-21 Winberg, G G Sivko, T N SIGNIFICANCE OF PHOTOSYNTHETIC AERATION IN
OXYGEN BALANCE OF POLLUTED WATERS lnt J Air and Water Pollution v 6 May-Aug 1962 p 267-275
Method of calculation of elements of oxygen balance; example calculations of atmospheric aeration oxygen consumption of riverbed and sessile vegetation and photosynthetic reaeration by fixed vegetation (EI 1962)
W-22 Wirts, J J CLEANING AIR DIFFUSION MEDIA Water and Sewage Works v 94 1947
W-23 Wisniewski, T F IMPROVEMENT OF THE QUALITY OF RESERVOIR DISCHARGES THROUGH TURBINE OR TAILRACE AERATION
U S Dept Health Education Welfare Symposium on Streamflow Regulation for Quality Control Public Health Service Pub No 999-WP-30 Jun 1965 p 299-316
Review the status of commercial-scale stream aeration on the Flambeau River, Fox River, and Wisconsin River; an evaluation of capital and operating costs is given for hydroturbine aeration
W-24 Wolf, P KORREFERAT ZU: IMHOFF, KUNSTLICHE BELUFTUNG
FUR DEN BALDENEYSEE UND DIE UNTERE RUHR (Coreview of: Imhoff, Artificial Aeration for the Baldeney Lake and the Lower Ruhr)
Gewasserschutz-Wasser-Abwasser Band 1 Aachen 1968
W-25 Wood, R COMPARISON STUDIES OF WINKLER VS OXYGEN SENSOR J Water Pollution Control Federation v 41 n 12 Dec 1969 p 2002
Determination of dissolved oxygen levels in waste water treatment and effluent disposal are of great use in a number of ways. In-plant laboratory studies of using a polarographic oxygen sensor in comparison with the more common Winkler method were conducted. Advantages found were: (a) the preparation and standardization of reagent solution are eliminated: (b) time spent in analysis is reduced; (c) the method is less tedious; and (d) correlation with the Winkler method is excellent. Laboratory experiences and data support these conclusions
W-26 Wurtz, B EFFECTS OF HEATED DISCHARGES ON AQUATIC LIFE AND WATER USE
ASME-Paper 61-WA-142 for meeting Nov 26-Dec 1 1961 Effects of heated discharges on biological structure of receiving stream; fish and bottom organisms discussed insofar as they are directly affected by heat; water uses that are temperature limited, also discussed, as are relationships between dissolved oxygen and temperature (EI 1962)
123
BASIC STUDIES streams photosynthesis oxidation reaeration
EQUIPMENT diffusers
EQUIPMENT streams turbine injection diffusers
EQUIPMENT streams reservoirs diffusers turbine injection mechanical aerators
economics
DO ANALYSIS instrumentation
BASIC STUDIES streams
y
Y-1 Yen, Ben Chie discussion of OXYGEN TRANSFER FROM FALLING WATER DROPLETS by Charles E. Carver, Jr.
Proc ASCE v 95 n SA 6 Apr 1969 p 1203-1205
Y-2 Yotsukura, Nobuhiro Fiering, Myron B NUMERICAL SOLUTION TO A DISPERSION EQUATION Proc ASCE v 90 n HY 5 Sep 1964 p 83-104
125
BASIC STUDIES experimental reaeration
BASIC STUDIES streams theoretical
Z-1
Z-2
Z-3
z Zieminski, SA Caron, M M Blackmore, R B BEHAVIOR OF AIR BUBBLES IN DILUTE AQUEOUS SOLUTIONS
lnd and Eng Cham-Fundamentals v 6 n 2 May 1967 p 233-242 Total transfer rate may be profoundly affected by some of investigated substances, e.g., heptanoic acid at concentration of 10 ppm increased rate of oxygen transfer by 180 percent; effects discussed in this report depend on air dispersing system; since principal action of substances appears to be in preventing coalescence of bubbles, their effectiveness will improve in systems where possibility of coalescence is greater; applicability to aeration systems, as used in fermentation processes and in treatment of sewage by bio-oxidation. 24 refs (EI 1967)
Zieminski, Stefan A Raymond, Delmar R USE OF CHEMICAL ADDITIVES TO IMPROVE AERATION
RATES: STUDY OF THE BEHAVIOR OF SINGLE BUBBLES-PROGRESS REPORT NO. 3a
Federal Water Pollution Control Admin Report R 848-4 Washington DC 1967 This report consists of two parts. Part 1 deals with methods of measuring rates of volume change of a rising gas bubble, its surface area, velocity of rise, and the instantaneous mass-transfer coefficient. The principle of this method was discussed in Progress Report No. 2a (1966). However, because of the changes introduced and the reproducibility tests conducted, the method is discussed in this report in detail. Special attention is given to the method of bubble release that proved to be an important factor affecting the consistency of results. Part 2 discusses effects of a homologous series of normal alcohols on mass-transfer and drag coeffieients of a carbon dioxide bubble. Carbon dioxide was used in the tests instead of air because of its higher solubility in water permitting greater accuracy of results. It may be expected that similar effects would take place in the case of air bubbles and thus help to better understand and possibly improve aeration systems. The study showed the depressing effect of an alcohol on KL increases with its chain length and concentration. A similar consistency of effects was also noticed in the case of drag coefficient which increased with concentration and chain length of the alcohol. 55 refs
Zieminski, Stefan A Lessard, Richard R USE OF CHEMICAL ADDITIVES TO IMPROVE AERATION
RATES: STUDY OF MODELS OF AIR DISPERSERSPROGRESS REPORT NO. 3b
Federal Water Pollution Control Admin Report R 848-4 Washington D C 1967 The investigation presented in this report deals with a method for improving the rates of aeration. In order to achieve this objective small quantities of some organic substances are introduced in the zone of bubble formation. These additives decrease bubble, coalescence and improve the rate of transfer because of the substantial increase in the interfacial surface area. The tests were conducted with n-octanol, 4-methyl-2-pentanol and heptaoic acid. At a concentration of 1 ppm the n-octanol and 4-methyl-2-pentanol showed an improvement in the rate of aeration of 70 percent over that in pure water. At a concentration of only 0.5 ppm n-octanol gave an improvement in the rate of transfer of 30 percent. Since the design of the aerator and the agent were not optimized, it may be expected that still better effect could be obtained in a large-scale installation. Federal Water Pollution Control Administratjon Grant WP-00562-04. 36 refs
126
BASIC STUDIES waste treatment bubbles experimental
BASIC STUDIES bubbles experimental reaeration
BASIC STUDIES bubbles experimental reaeration
Z-4
Z-$
Z-Continued
Zieminski, SA Raymond, D R EXPERIMENTAL STUDY OF BEHAVIOR OF SINGLE BUBBLES Chern Eng Sci v 23 n 1 Jan 1968 p 17-28
Method is described for measurements of rates of volume ctia~ of rising gas bubble, its surface area, velocity of rise, and instantaneous mass-transfer coefficient; prihciple of this method is to follow, by means of high-speed photography, motion of bubble simultaneously with changes in volume as indicated by capillary of dilatometer; in this way almost continuous record is obtained of bubble volume, shape, and oscillation, as related to height of bubble in liquid and time elapsed from moment of bubble release; relevant to operation of air lifts, mammoth pumps, and sulfur pumping in Frasch process. 31 refs ( E I 1968)
Zhavoronkov, N M Romankov, P G OSNOVNYE NAPRAVLENIYA NAUCHNYKH ISSLEDOVANII V
OBLASTI MASSOOBMENNYKH PROTESESSOV KHIMICHESI<OI TEKHNOLOGII
Khimicheskaya Promyshlennost n 2 Feb 1965 p 1-4 Main trends in scientific research of mass-exchange proces'\es in chemical technology; present state and future program of research concerned with studies of theoretical problems of physicochemical hydrodynamics and mass exchange; phase equilibria and constants in systems gas-liquid, vapor-liquid, and liquid-liquid, particularly in nonideal and multico,tnponent systems; calculations of basic processes of mass exchange; mathematical modeling and descriptions of technology of mass-exchange processes. In Russian (EI 1966)
127
BASIC STUDIES bubbles experimental
BASIC STUDIES reaeration
BIBLIOGRAPHY INDEX
BASIC STUOI ES-B-7
Streams- -7, A-5, B-2, B-11, B-14, B-23, 8-25, 8-35, C-2, C-3, C-9, C-11, C-12, C-21, C-26, 0-7, 0-10, 0-11,
0-121 0-13, 0-181 0-191 0-201 E-4-~-E~5~ E-8~ F-4, G-2~ G-4~ G-5~ G-8~ G-131 G-14, G-191 H-41 H-71 H-141
H-22, 1-1~ 1-4, 1-10, 1-11, K-7, K-8, K-21, K-22, K-23, K-241 K-261 L-3, L-8, L-13, L~14; L-17, L-18, L-21 1
M-5~ M-9, M-10, M-17, M-23, N-6, 0-1, 0-2, 0-3, 0-5,0-6,0-7,0-8,0-9,0-10, P-8, P-9, P-10, P-14, P-20,
0-2~ R-11, S-8, S-141 S-19, S-20, S-32, S-331 S-341 S-351 S-361 S-371 T-2~ T-9, T-10, T-11 1 T-12, T-13, T-14,
T-171 T-22, T-25, T-261 T-27, T-281 T-291 T-30, V-1~ V-5, V-61 V-71 W-61 W-9, W-21 1 W-261 Y-2
Reservoirs-A-6, C-8, C-101 C-13, C-14, 0-20, F-3~ H-19, H-22, 1-41 1-61 1-7, K-101 K-141 K-15, K-17, K-251
K-26, L-6~ L-191 L-20, M-1~ M-26, M-28, N-2, P-3, R-1~ S-7, S-101 S-421 S-44, S-451 S-461 S-47, S-481 T-11 T-8, V-1, V-8, W-15
Estuaries-0-12, H-201 J-101 0-4~ T-191 T-20
Wastetreatment-8-131 8-34, G-121 G-151 1-81 K-16, M-3, Z-1
8ubbles-C-1, C-7 I c" 181 C-191 D-1, D-3, D-4, D-5, E-1, F-91 G-1 I G-161 G-21, H-51 H-17 I J-4, J-81 K-27, L-12,
M-6, M-71 N-1, P-151 P-16, R-3~ R-121 S-31 S-391 T-23, Z-1 1 Z-21 Z-3, Z-4
Theoretical-8-11, C-1, C-1~ C-191 0-2~ D-13, D-191 F-4~ F-91 G-1~ G-2~ G-161 H-4~ H-5, H-10, H-241 1-10, J-1,
J-41 K-101 K-13, K-14, K-161 K-221 K-23, K-26, L-11, L-121 L-131 L-17, L-18, M-18, 0-2 1 0-4 1 P-11 1 P-15,
P-16, 0-2, R-12, R-13, R-14, S-141 T-21 T-17, T-181 T-19, W-14, Y-2
Experimental- -7, A-1 I A-5, A-131 8-2~ 8-4~ 8-6, 8-13, 8-14, 8-23, 8-251 8-341 B-351 C-1, C-21 C-3~ C-5, C-8~
C-9, C-1 01 C-11 I C-121 C-13, C-141 C-181 C-201 C-21 I C-261 C-27 I D-1 I 0-31 D-41 0-51 D-71 D-1 01 D-11 I D-12,
0-131 0-16, 0-17, D-20, E-1, E-4, E-5, E-6, E-8, F-3, F-4, F-91 G-2, G-3~ G-41 G-51 G-81 G-121 G-13, G-14,
G-151 G-161 G-19, G-21, H-2~ H-41 H-61 H-10, H-141 H-171 H-181 H-19, H-201 H-21 1 H-22, H-241 1-1~ 1-2,1-4,
1-61 1-71 1-81 1-11 1 J-81 J-101 K-8, K-10, K-161 K-171 K-21 1 K-221 K-231 K-24, K-25, K-261 K-27, L-3~ L-6, L-8~
L-121 L-191 L-21, M-1 1 M-3, M-51 M-61 M-11 M-9, M-101 M-171 M-231 M-26, M-271 N-1~ 0-1~ 0-3~ 0-4~ 0-6~
0-9, P-31 P-81 P-10, 0-21 R-1 1 R-31 R-11 1 S-3, S-7, S-191 S-20, S-34, S-351 S-39, T-13, T-201 T-211 T-231 T-241
T-25, T-26, T-27, T-281 T-291 T-30, V-2, V-41 W-61 W-9, Y-1, Z-1, Z-2~ Z-3, Z-4
129
BIBLIOGRAPHY INDEX-Continued
Reaeration-A-1, A-5, A-6, A-13, B-4, B-1 0, B-13, B-14, B-23, B-25, B-35, C-1, C-2, C-3, C-5, C-8, C-9, C-1 0,
C-11, C-12, C-13, C-14, C-20, C-21, C-17, 0-2, 0-7,0-10,0-11,0-12,0-13,0-16, D-17, D-18, 0-19, 0-20,
E-4, E-8, F-8, G-2, G-3, G-4, G-5, G-19, H-4, H-6, H-7, H-10, H-14, H-24, 1-1, 1-4, 1-11, K-8, K-13, K-21,
K-22, K-23, K-24, K-26, L-3, L-8, L-11, L-13, L-18, L-21, M-3, M-5, M-15, M-16, M-17, M-18, M-27, N-6,
0-2, 0-3, 0-5, 0-9, 0-10, P-9, P-10, P-11, P-14, P-20, 0-2, R-13, R-14, S-8, S-19, S-28, S-29, S-34, S-35,
S-36, S-37, T-2, T-10, T-11, T-13, T-14, T-17, T-24, T-25, T-27, T-28, T-29, T-30, V-2, V-5, V-6, W-6, W-14,
W-21, Y-1, Z-2, Z-3, Z-5
Oxidation-C-8, C-10, C-13, C-14, C-26, 0-11, 0-19, G-8, G-19, H-2, 1-7, 1-8, 1-10, K-8, K-16, K-21, L-8, L-18,
L-19, M-5, M-9, N-2, 0-5,0-6,0-7, P-20, 0-2, R-11, S-7, S-32, S-33, S-36, S-37, T-17, T-21, T-26, V-4, V-5,
V-7, W-9, W-21
Photosynthesis-B-2, B-6, C-3, E-5, H-18, H-19, H-20, 1-2, J-1, M-1, V-8, V-9, W-21
Respiration-8-2, G-19, M-1 0, 0-1
EQUIPMENT -1-3, L-10
Streams- -6, A-3, A-4, A-7, A-8, A-9, B-3, B-5, B-28, B-30, B-33, C-16, D-21, E-3, E-7, G-6, G-7, G-9, G-17,
H-16, 1-5, K-3, K-6, L-9, L-16, M-4, P-1, 0-1, S-5, S-6, S-21, S-22, S-23, S~40, S-41, T-15, T-33, T-34, T-35,
W-1, W-2, W-3, W-4, W-10, W-11, W-12, W-16, W-17, W-18, W-19, W-20, W-23, W-24
Reservoirs- -3, -4, -5, B-15, 8-27, 8-29, 8-31, C-15, D-6, F-6, F-7, H-1, H-9, H-11, H-12, H-15, 1-5,1-9, K-18,
K-19, K-20, L-1, M-13, M-14, P-7, 0-1, R-2, R-7, S-2, S-4, S-18, S-22, S-38, S-43, S-46, S-49, T-5, T-16,
W-24
Waste treatment- -9, -10, A-2, A-11, B-1, B-9, 8-12, 8-16, B-17, 8-18, 8-20, B-21, B-22, B-24, B-26, B-32, C-4,
C-6, C-23, C-24, D-8, D-14, E;-2, E-9, E-10, F-2, F-5, G-18, G-20, H-23, J-3, J-7, K-2, K-3, K-11, K-12, L-5,
L-7, M-2, M-11, M-19, M-21, M-24, M-25, N-3, N-4, N-5, P-4, P-5, P-6, P-12, P-13, R-4, R-15, S-9, S-16,
S-27, S-31 I T-3, T-4, W-5, W-13
Diffusers- -1, -4, -9, A-9, A-12, 8-9, 8-15, B-16, B-17, B-18, 8-20, B-24, 8-31, 8-33, C-4, C-6, C-15, C-24, D-6,
D-8, 0-15, F-5, F-6, F-7, G-10, H-9, H-11, H-12, 1-5, J-7, K-2, K-12, K-18, K-19, L-1, L-2, L-7, M-2, M-19,
M-20, M-21, N-4, P-1, P-5, P-6, P-7, P-17, 0-1, R-2, R-4, R-7, R-10, R-15, S-1, S-2, S-4, S-18, S-31, S-38,
S-43, S-46, S-49, T -5, T -15, T -16, T -33, T -34, W-5, W-11, W-12, W-20, W-22, W-23, W-24
Mechanical aerators-8-1, 8-21, 8-30, 8-33, C-17, C-23, 0-15, H-23, 1-5, J-3, K-3, K-4, L-4, M-11, M-12, M-24,
N-5, P-18, 0-1, S-16, S-17, S-27, S-40, T-15, W-8, W-11, W-12, W-13, W-24
130
BIBLIOGRAPHY INDEX-Continued
Pressure injection- -3, T-15
Molecular oxygen- -10, A-7, A-8, A-9, S-22
Turbine injection-A-7, A-8, A-9, 8-3, B-33, 0-21, E-3, 1-5, L-9, P-1, 0-1,0-2, S-5, S-6, S-30, T-15, W-2, W-4,
W-16, W-17, W-18, W-19, W-23, W-24
Cascades-A-3, A-4, B-5, 0-15, G-6, G-7, G-9, G-17, H-16, L-15, M-4, S-5, S-41, T-15
Pumps- -5, H-15, 1-9, S-46
U-tubes-B-28, S-21, S-23, S-24, S-25, S-26, T-15
Howeii-Bunger valves-E-7
Mise equipment- -11, H-1, L-5, M-13, M-14, M-25, T -1
Mise uses-A-2, B-31, E-1 0, G-1 0, H-9, R-2, S-12, S-13, S-18, S-38
Venturis-B-8, J-2
Hydraulic guns-B-27, K-20, T-16
Economics-K-1, 0-1, S-1, T-5, W-10, W-11, W-24
GENERAL-B-19, F-1, H-3, H-25, J-5, K-9, P-19, R-5, R-6, T-6, W-7
Reviews- -8, S-11, T-15, T-16
Criteria-C-22, C-25
Economics-C-25, H-8
Terms-G-11, H-13
CAVITATION-0-9, J-9, M-8, P-2, R-9, T-31, T-32, V-3
DO ANALYSIS- -2
lnstrumentation-A-10, H-22, J-6, K-5, M-22, R-8, S-15, W-25
131
7-!750 (1-70) Bureau of Reclamation
CONVERSION FACTORS--BRITISH TO METRIC UNITS OF MEASUREMENT
The following conversion factors adopted by the Bureau of Reclamatio:1 are those published by the American .Society for TestinJ and Materials (ASTM Metric Practice Guide, E 380-68) except that additional factors (*) commonly u.sed in the Bureau have been added. Further discussion of definitions of quan':ities and units is given in ~he ASTM Metric Practice Guide.
The metric units and ·conversion factors adopted by the ASTM are based on the "International &;stem of Units" (design:tted SI for Systeme International d'Unites), fixed by the International Committee for Weights and Measures; this system is also known as the Giorgi or MKSA (meter-kilogram (mass)-second-ampere) system. This system has been adopted by the International Organization for Standardization in ISO Recommendation R-31.
The metric technical unit of force is the kilogram-force; this is the force which, when applied to a body having a mass of 1 kg, gives it an acceleration of 9. 80665 m/secjsec, the standard acceleration of free fall toward the earth's center for sea level at 45 deg latitude. The metric unit of force in SI units is the newton (N), which is defined as that force which, when applied to a body having a mass of 1 kg, gives it an acceleration of 1 m/sec/sec. These units must be distinguished from the (inconstant) local weight of a body having :t mass of 1 kg; that is, the weight of a body is that force with which a b:::>dy is attracted to the earth and is equal to the mass of a body multiplied by the acceleration due to gravity. However, because it is general practice to use "pou..nd" rather than the technically correct term "pound-force," the term "kilogram" (or derived mass unit) has been used in this guide instead of "kilogramforce" in expressing the conversion factors for forces. The newton unit of force will find increasing use, and is essential in SI units.
Where approximate or n:::Jminal English units are used to express a value or range of values, the converted metric units in parentheses are also approximate :::Jr nominal. Where precise English units are ased, the converted metric units are expressed as equally significant values.
Multiply
Mil. . Inches •
Feet .•
Yards •... Miles (statute). •
Square inches . Square feet .
Square yards Acres ••.
Square miles
Cubic inches Cubic feet •. Cubic yards .
Fluid ounces (U.S.) •
Liquid pints (U.S.)
Quarts (U.S.) ••
Gallons (U. S. ) •
Gallons (U. K. f · Cubic feet. . Cubic yards . Acre-feet ••.
Table I
QUANTITIES AND UNITS OF SPACE
By
LENGTH
25. 4 (exactly). 25. 4 (exactly). .
2. 54 (exactly)*. 30. 48 (exactly) • . .
0. 3048 (exactly)*. . 0. 0003048 (exactly)* . 0. 9144 (exactly) .
1, 609.344 (exactly)* . 1. 609344 (exactly) •
AREA
6. 4516 (exactly) . 929. 03* .•
0. 092903 . 0. 836127 . 0. 40469* .
4, 046. 9* . . . 0.0040469* 2. 58999 ..
VOLUME
16.3871 .... 0. 0283168 .. 0. 764555 . .
CAPACITY
29.5737 • 29.5729 .
0.473179 0. 473166 .
946. 358* .• 0. 946331*.
3,785.43* 3. 78543 .. 3. 78533 .. 0
0. 00378543*. 4.54609 4.54596
28.3160 764.55*
. 1, 233. 5* •
. 1, 233, 500*
To obtain
Micron Millimeters Centimeters Centimeters Meters Kilometers Meters Meters Kilometers
Square centimeters Square centimeters Square meters Square meters Hectares Square meters Square kilometers Square kllometers
Cubic centimeters . • Cubic meters
:._.;:......:---.:Cu=b:.:i.:::.c me...._te""r""s;;;__ __ _
Cubic centimeters Milliliters Cubic decimeters Liters Cubic centimeters Liters Cubic centimeters Cubic decimeters
• Liters • Cubic meters
Cubic decimeters Liters Liters
• Liters Cubic meters Liters
Table II
QUANTITIES AND UNITS OF MECHANICS
Multiply By To obtain
Grains (1/7, 000 lb) . . . Troy ounces (480 grains). Ounces (avdp). . . . Pounds (avdp) •... Short tons (2, 000 lb).
Lonq tons (2, 240 lb):
Pounds per square inch
MASS
64. 79891 (exactly) . . Milligrams 31. 1035 . . . . . . . Grams 28. 3495 . . . . . . . Grams 0. 45359237 (exactly). Kilograms
907. 185 . . Kilograms . 0. 907185. . . . . . Metric tons . 1, 016. 05. . . . . . . . Kiloqrams
FORCE/AREA
0. 070307. Kilograms per square centimeter 0. 689476. Newtons per square centimeter
Pounds per square foot 4. 88243 . Kilograms per square meter
Ounces per cubic inch . . . Pounds per cubic foot . . .
Tons (lonq) per cubic Va.rd. :
Ounces per gallon (U.S, ) Ounces per gallon (U. K. ) Pounds per gallon (U.S.) Pounds per qallon (U.K.)
Inch-pounds
Foot-pounds
Foot-pounds per' i~ch Ounce-inches. . • .
Feet per second.
Feet per year. • Miles per hour .
47. 8803. • Newtons per ~re meter
MASS/VOLUME (DENSITY)
1. 72999 . 16.0185 . 0. 0160185 1. 32894
MASS/CAPACITY
7. 4893. 6. 2362.
119.829 . 99. 779 .
BENDING MOMENT OR TORQUE
~: ~~~~~\ 1o6: ~: 5~~~~5x' 107: 5. 4431. • . .
72.008 ....
VELOCITY
30. 48 (exactly). . . 0. 3048 (exactly)* . 0. 965873 X 10-6* , 1. 609344 (exactly), 0. 44704 (exactl
ACCELERATION*
Grams per cubic centimeter Kilograms per cubic meter Grams per cubic centimeter Grams per cubic centimeter
Grams per liter Grams per liter Grams per liter Grams per liter
Meter-kilograms Centimeter-dynes Meter-kilograms Centimeter-dynes Centimeter-kilograms per centimeter Gram-centimeters
Centimeters per second Meters per second Centimeters per second Kilometers per hour Meters per second
Feet per second2 . . . . . . • . • . 0. 3048* . . . . . . . . . . Meters per second2
Cubic feet per second (secondfeet) ..•.••....
Cubic feet per minute . • . . . Gallons (U.S. ) per minute • . .
Pounds.
FLOW
0. 028317* 0. 4719 . 0. 06309 .
FORCE*
0. 453592* . . .
t !!~rx 10-6* :
Cubic meters per second Liters per second Liters per second
Kilograms Newtons Dynes
Multiply
British thermal units (Btu) .
Btu per pourid. . . . . . . Foot-pounds . . . . . • .
Horsepower • . . . . . Btu per hour . . . . . . Foot-pounds per second .
Btu in. /hr ft2 deg F (k, thermal conductivity)
2 ••• Btu ft/hr ft deg F . • • . •
B~%%~i!n~~} F. (~,. t~er.m~. Deg F hr ft2/Bt~ (R,' the;m"al'
resistance) . • • • • . • • . Btu/lb deg F (c, heat capacity) .
~~~~~ ~fge~m'al' dlff~si'vityl
Grains/hr n2 (water vapor transmission) • • . • - • •
Perms (permeance) . . . . Perm-inches (permeability)
Bv
WORK AND ENERGY*
. 0. 252*
. 1,055.06 .... 2. 326 (exactly) 1. 35582*. .
POWER
745. 700 . . 0. 293071. 1. 35582 •
HEAT TRANSFER
1. 442 . 0.1240. 1. 4880*
0. 568 4. 882
1. 761 4.1868 1. 000* 0. 2581 . 0. 09290*.
WATER VAPOR TRANSMISSION
16. 7 0. 659 1. 67
Table III
OTHER QUANTITIES AND UNITS
Multiply By
Cubic feet per square foot per
To obtain
Kilogram calories Joules . Joules per gram Joules
Watts Watts Watts
Milliwatts/cm deg C
~g ~:ll~/h~ :~ 2eg C
M1lliwatts/cm2 deg C Kg cal/hr m<: deg C
Deg C cm2/milliwatt J/g deg C Cal~gram deg C
~w;t:ec
Grams/24 hr m2 Metric perms Metric perm-centimeters
To obtain
day (seepage) . . . . . . • . . 304. 8* . . . Liters per square meter per day Pound-seconds per square foot
(viscosity) • • . . . . . . . • 4. 8824*. . Kilogram second per square meter Square feet per second (viscosity). 0. 092903*. . Square meters per second Fahrenheit degrees (change)*. 5/9 exactly . Celsius or Kelvin degrees (change)* Volts per mil. . . . . . . . 0. 03937. Kilovolts per millimeter
L~:ne;{~s)er. s;u~~ ~o~t ~o~t~ 10. 764. . . Lumens per square meter Ohm-circular mils per foot 0. 001662 . Ohm-square millimeters per meter Millicuries per cubic foot . 35. 3147* . Milllcuries per cubic meter Milliamps per square foot . 10. 7639* . Milliamps per square meter Gallons per square yard . • 4. 527219* Liters per square meter Pounds ]:leLJ.nch. . . . . • 0. 17858*. KHoqrams per centimeter
GP0833-421
....................................................................................................................................................................
ABSTRACT
Bureau of Reclamation responsibility for maintaining or enhancing 'the water quality assori==tted with its projects· has resulted in a comprehensive program of research in water quality and pollution control. A literature search and state-of-the-art review to determine the need for future research in reaeration of streams and reservoirs revealed a large number of references concerning the application of aeration methods and equipment to waste treatment. Generally, the application of this technology to aeration· of large volumes of water such as rivers and reservoirs remains to be developed, although several applicable references were found. Questions regarding atmospheric reaeration in streams remain unresolved. Research is also needed regarding the aeration capability of hydraulic structures and control devices, development of new methods and equipment, effects of dissolved air on cavitation, and comparative economics of various methods and equipment. Ecological effects of reaeration are being considered in a separate review.
ABSTRACT
Bureau of Reclamation responsibility for maintaining or enhancing the water quality associated with its projects has resulted in a comprehensive program of research in water quality and pollution control. A literature search and state-of~the-art review to determine the need for future research in reaeration of streams and reservoirs revealed a large number of references concerning the application of aeration methods and equipment to waste treatment. Generally, -the application of this technology to aeration of large volumes of water such as rivers and reservoirs remains to be developed, although several applicable references were found. Questions regarding atmospheric reaeration in streams remain unresolved. Research is also needed regarding the aeration capability of hydraulic structures and control devices, development of new methods and equipment, effects of dissolved air on cavitation, and comparative economics of various methods and equipment. Ecological effects of reaeration are being considered in a separate review.
I •• -· •••• e e e • e • e e. e e e • e e •• e e • e •• e e • e • e e e • e e e • e • e e e e e e e ••• e • e e • e • e e e e e • e e e •• e e e • e e • e ••• e • e • e e • e ••• e • e e •• e e • e •• e • e • e e • e e e e •••• e ••••• e •••••• e • e e ••• e •• e • e • e •• e e e e •••••• e •
ABSTRACT
Bureau of Reclamation responsibility for maintaining or enhancing the water quality associated with its projects has resulted in a comp~hensive program of research in water quality and pollution control. A literature search and $tate-of-the-art review to determine the need for future research in reaeration of streams ana reservoirs revealed a large number of references concerning the application of aeration methods and equipment to waste treatment. Generally, the application of this technology to aeration of large volumes of water such as rivers and reservoirs remains to be developed, although several applicable references were found. Questions regarding atmospheric reaeration in streams remain unresolved. Research is also needed regarding the aeration capability of hydraulic structures and control devices, development of new methods and equipment, effects of dissolved air on cavitation, and comparative economics of various methods and equipment. Ecological effects of reaeration are being considered in a separate review.
ABSTRACT
Bureau of Reclamation responsibility for maintaining or enhancing the water quality associated with its projects has resulted in a comprehensive program of research in water quality and pollution control. A literature search and state-of-the-art review to determine the need for future research in reaeration of streams and reservoirs revealed a large number of references concerning the application of aeration methods and equipment to waste treatment. Generally, the application of this technology to aeration of large volumes of water such as rivers and reservoirs remains to be developed, although several applicable references were found. Questions regarding atmospheric reaeration in streams remain unresolved. Research is also needed regarding the aeration capability of hydraulic structures and control devices, development of new methods and equipment, effects of dissolved air on cavitation, and comparative economics of various methods and equipment. Ecological effects of reaeration are being considered in a separate review.
REC-OCE-70-55 King, D L REAERATION OF STREAMS AND RESERVOIRS-ANALYSIS AND BIBLIOGRAPHY Bur Reclam Rep REC-OCE-70-55, Div GenRes, Dec 1970. Bureau of Reclamation,Denver, 131 p, 2 fig, 7 tab, 448 ref
DESCRIPTORS-/ *aeration/ *streams/ *reservoirs/ instrumentation/ oxygen sag/ mathematical analysis/ theory/ mass transfer/ equipment/ *dissolved oxygen/ methodology/ industrial waste treatment/ sewage treatment/ water quality/ efficiencies/ economics/ *bibliographies/ *reviews/ cavitation/ biochemical oxygen demand/ *reaeration/ oxygen requirements I DE NT IF IE RS-/ cavitation control/ oxygen exchange I em pi rica I equations/ formulas
R EC-OCE-70-55 King, D L REAERATION OF STREAMS AND RESERVOIRS-ANALYSIS AND BIBLIOGRAPHY Bur Reclam Rep REC-OCE-70-55, Div GenRes, Dec 1970. Bureau of Reclamation,Denver,131 p, 2 fig, 7 tab, 448 ref
D ESC R I PTO R S -/ *aeration/ *streams/ *reservoirs/ instrumentation/ oxygen sag/ mathematical analysis/ theory/ mass transfer/ equipment/ *dissolved oxygen/ methodology/ industrial waste treatment/ sewage treatment/ water quality/ efficiencies/ economics/ *bibliographies/ *reviews/ cavitation/ biochemical oxygen demand/ *reaeration/ oxygen requirements IDE NT I F I E R S-/ cavitation control/ oxygen exchange/ em pi rica I equations/ formu I as
R EC-OCE-70-55 King, D L REAERATION OF STREAMS AND RESERVOIRS-ANALYSIS AND BIBLIOGRAPHY Bur Reclam Rep REC-OCE-70-55, Div GenRes, Dec 1970. Bureau of Reclamation,Denver,131 p, 2 fig, 7 tab, 448 ref
D ESC R I PTO R S-/ *aeration/ *streams/ *reservoirs/ instrumentation/ oxygen sag/ mathematical analysis/ theory/ mass transfer/ equipment/ *dissolved oxygen/ methodology/ industrial waste treatment/ sewage treatment/ water quality I efficiencies/ economics/ *bibliographies/ *reviews/ cavitation/ biochemical oxygen demand/ *reaeration/ oxygen requirements I DE NT I FIE RS-I cavitation control/ oxygen exchange/ empirical equations/ formu I as
REC-OCE-70-55 King, D L REAERATION OF STREAMS AND RESERVOIRS-ANALYSIS AND BIBLIOGRAPHY Bur Reclam Rep REC-OCE-70-55, Div Gen Res, Dec 1970. Bureau of Reclamation,Denver, 131 p, 2 fig, 7 tab, 448 ref
D ESC R I PTO RS-/ *aeration/ *streams/ *reservoirs/ instrumentation/ oxygen sag/ mathematical analysis/ theory/ mass transfer/ equipment/ *dissolved oxygen/ methodology/ industrial waste treatment/ sewage treatment/ water quality/ efficiencies/ economics/ *bibliographies/ *reviews/ cavitation/ biochemical oxygen demand/ *reaeration/ oxygen requirements IDENTIFIERS-/ cavitation control/ oxygen exchange/ empirical equations/ formulas