June 07, 2012 Mr. Roland Peterson Wyoming Department of Environmental Quality Water Quality Division 122 West 25th Street, Herschler Building, 4-W Cheyenne, Wyoming 82002 RE: WY0027316 Bailey Dome, WYPDES Renewal Application Legacy Reserves Operating, LP Dear Mr. Peterson, Legacy Reserves Operating, LP (Legacy) respectfully submits the enclosed WYPDES renewal application for its WY0027316 Bailey Dome oil facility. Enclosed for your consideration are the following: WYPDES Permit Renewal Application for Oil and Gas Discharge Flow Data Table Representative Water Quality MSDS Sheets Facility Diagram Permit Application Map Under the current permit, Legacy pipes produced water from up to six (6) production wells completed in the Tensleep and Nugget formations. The production streams from the two (2) producing formations are kept separate. The Nugget production stream first passes through a free-water knockout (FWKO) for initial separation. Free water is sent to two (2) 1000 bbl produced water skimming tanks. From the skimming tanks, the water is piped to two (2) fenced and netted skimming ponds that are situated in a cascading fashion that discharges water to an unnamed drainage through outfall 001. Oil from the Nugget formation goes from the FWKO to one (1) heater treater for further separation. Water that is removed in this process is sent to the two (2) 1000 bbl produced water skimming tanks mentioned above and then to the skimming ponds to be discharged through outfall 001. The produced oil is piped to four (4) 400 bbl oil tanks, which is then loaded out by truck for sales once adequate volumes have accumulated. The production stream from the Tensleep formation follows the same treatment process as the Nugget formation with the exception of instead of four (4) 400 bbl oil tanks, there are two (2) 500 bbl oil tanks associated with the Tensleep produced oil. With this renewal application, Legacy would also like to update the qtr/qtr and latitude/longitude for outfall 001 to its as-built location. If you have any questions, please contact me at (307) 587-7232 or [email protected] ; you may also contact Bret Bergstrom of InterTech Environmental & Engineering, LLC at (307) 742- 4991 or [email protected] .

Transcript of RE: WY0027316 Bailey Dome, WYPDES Renewal …deq.state.wy.us/wqd/WYPDES_Permitting/WYPDES_PNs... ·...

June 07, 2012 Mr. Roland Peterson Wyoming Department of Environmental Quality Water Quality Division 122 West 25th Street, Herschler Building, 4-W Cheyenne, Wyoming 82002

RE: WY0027316 Bailey Dome, WYPDES Renewal Application Legacy Reserves Operating, LP

Dear Mr. Peterson, Legacy Reserves Operating, LP (Legacy) respectfully submits the enclosed WYPDES renewal application for its WY0027316 Bailey Dome oil facility. Enclosed for your consideration are the following:

• WYPDES Permit Renewal Application for Oil and Gas Discharge • Flow Data Table • Representative Water Quality • MSDS Sheets • Facility Diagram • Permit Application Map

Under the current permit, Legacy pipes produced water from up to six (6) production wells completed in the Tensleep and Nugget formations. The production streams from the two (2) producing formations are kept separate. The Nugget production stream first passes through a free-water knockout (FWKO) for initial separation. Free water is sent to two (2) 1000 bbl produced water skimming tanks. From the skimming tanks, the water is piped to two (2) fenced and netted skimming ponds that are situated in a cascading fashion that discharges water to an unnamed drainage through outfall 001. Oil from the Nugget formation goes from the FWKO to one (1) heater treater for further separation. Water that is removed in this process is sent to the two (2) 1000 bbl produced water skimming tanks mentioned above and then to the skimming ponds to be discharged through outfall 001. The produced oil is piped to four (4) 400 bbl oil tanks, which is then loaded out by truck for sales once adequate volumes have accumulated. The production stream from the Tensleep formation follows the same treatment process as the Nugget formation with the exception of instead of four (4) 400 bbl oil tanks, there are two (2) 500 bbl oil tanks associated with the Tensleep produced oil. With this renewal application, Legacy would also like to update the qtr/qtr and latitude/longitude for outfall 001 to its as-built location. If you have any questions, please contact me at (307) 587-7232 or [email protected]; you may also contact Bret Bergstrom of InterTech Environmental & Engineering, LLC at (307) 742-4991 or [email protected].

June 07, 2012 Renewal for Bailey Dome WYPDES Permit WY0027316 Legacy Reserves Operating, LP Cover Letter, Page 2 of 2

Sincerely, Legacy Reserves Operating, LP Scott Bliss Environmental Coordinator /bkb Enclosures cc: Legacy Reserves Operating, LP – File InterTech E&E - File

sbliss
Stamp

SUBMIT ONE HARD COPY AND ONE ELECTRONIC COPY (CD)

WYOMING POLLUTANT DISCHARGE ELIMINATION SYSTEM APPLICATION FOR PERMIT TO SURFACE DISCHARGE PRODUCED WATER FROM

OIL AND GAS PRODUCTION UNIT DISCHARGES

Revised March 1, 2012 PLEASE PRINT OR TYPE (Submission of illegible materials will results in return of the application to the applicant) 1. The discharging facility will produce:

Oil Oil and natural gas Natural gas Check the box corresponding to the type of application being applied for:

New Permit

Permit Renewal. Permit number WY0027316 Expiration Date: 11/30/2012

Permit Modification. Permit number _____________ Expiration Date: _______________

(For permit modification, please attach letter explaining modifications requested.) 2. Company, Contact Name, mailing address, e-mail address, and telephone number of the individual or company which

owns the facility producing the discharge, and the person (consultant) responsible for permit submission. Company Contact Name Scott Bliss

Consultant Contact Name Bret Bergstrom

Company Name Legacy Reserves Operating, LP

Company Name InterTech Environmental & Engineering, LLC

Mailing Address 1501 Stampede Avenue, 3rd Floor, Suite 3170

Mailing Address 3821 Beech Street

City, State, and Zip Code Cody, WY 82414

City, State, and Zip Code Laramie, WY 82070

Telephone Number 307-587-7232

Telephone Number 307-742-4991

E-Mail Address [email protected]

E-Mail Address [email protected]

Status of applicant as owner, operator or both - Operator Status of applicant as federal, state, private or public - Private 3. Name of the facility (lease, tank battery #, etc.) producing the discharge (this is the facility name that will appear on the WYPDES

permit. It is not necessary to name every well contributing to this facility’s discharge in this section) Bailey Dome

For Agency Use Only

Application Number WY00_______________

Date Received:

__________________

(mo/day/yr)

WYPDES Renewal ApplicationLegacy Reserves Operating, LP

Bailey Dome - WY0027316HUC 10 - 1404020015

June 07, 2012Page 1 of 36

4. Name(s) and mailing address(es) of owner(s) of the surface rights on whose land the discharge occurs (in cases where the land is owned by the state or federal government but surface rights are leased to a private individual, provide lessee’s name and address)

Landowner #1 Name Gwendolyn S. Chapman

Mailing Address 2507 Pine Needle CT City, State, and Zip Code Fort Collins, CO 80528

WYPDES Renewal ApplicationLegacy Reserves Operating, LP

Bailey Dome - WY0027316HUC 10 - 1404020015

June 07, 2012Page 2 of 36

5. Provide outfall information in Table 1 below.

TABLE 1. Outfall information

* The mainstem is the closest perennial water (class 2). Stream distance from the outfall to the mainstem should be measured in stream miles versus as “the crow flies”.

Discharge Point

(Outfall) #

Immediate Receiving

Stream

Mainstem*

(Nearest

Perennial

Water)

Distance from outfall

to main stem

(stream miles) *

Quarter/

QuarterSection Township

Range

Latitude

(NAD 83, decimal degree format,

accuracy to nearest 5 decimal

places)

Longitude

(NAD 83, decimal degree format,

accuracy to nearest 5 decimal places)

County

001 Unnamed Drainage

Closed Drainage 0.9 NENE 21 26N 89W 42.216025 -107.468073 Carbon

WYPDES Renewal ApplicationLegacy Reserves Operating, LP

Bailey Dome - WY0027316HUC 10 - 1404020015

June 07, 2012Page 3 of 36

6. Describe measures to prevent access to the skimming ponds by large grazing animals. Skimming ponds are fenced.

7. Describe measures employed to deter/exclude migratory birds from the skimming ponds.

Skimming ponds are netted.

8. Attach a description and clear, legible, detailed topographic map of the discharging facility extending one mile beyond the property boundaries of the source. Include the following:

a. A legend

b. Discharge points (outfalls) c. Immediate receiving streams d. Section, Township, and Range information e. Well locations f. Water flow lines

9. Attach a site diagram. Include the following:

a. Water flow lines b. Treater units c. Skimming tanks d. Skimming Ponds e. Stock tanks – Stock tanks are not present at facility. If any of the above items in 8 or 9 are not applicable please indicate in the description and include a brief explanation as to why the items are not applicable)

10. Describe the control measures that will be implemented to achieve water quality standards and effluent limits. If proposing

to utilize a treatment process, provide a description of the treatment process. Include list of chemicals used and provide a Material Safety Data Sheet (MSDS) for each chemical.

Under the current permit, Legacy pipes produced water from up to six (6) production wells completed in the Tensleep and Nugget formations. The production streams from the two (2) producing formations are kept separate. The Nugget production stream first passes through its respective free-water knockout (FWKO) for initial separation. Free water is sent to two (2) 1000 bbl produced water skimming tanks. From the skimming tanks, the water is piped to two (2) fenced and netted skimming ponds that are situated in a cascading fashion that discharges water to an unnamed drainage through outfall 001. Oil from the Nugget formation goes from the FWKO to its respective heater treater for further separation. Water that is removed in this process is sent to the two (2) 1000 bbl produced water skimming tanks mentioned above and then to the skimming ponds to be discharged through outfall 001. The produced oil is piped to four (4) 400 bbl oil tanks, which is then loaded out by truck for sales once adequate volumes have accumulated. The production stream from the Tensleep formation follows the same treatment process as the Nugget formation with the exception of instead of four (4) 400 bbl oil tanks, there are two (2) 500 bbl oil tanks associated with the Tensleep produced oil. Below is a list of chemicals that are used to achieve water quality standards, please see attached MSDS sheets for more detail.

• EC6033A – Water Clarifier • EC6031A – Water Clarifier

11. Describe the control measures that will be implemented to prevent significant damage to or erosion of the receiving water

channel at the point of discharge. Rip rap and or geotextile is placed at discharge point to prevent erosion.

WYPDES Renewal ApplicationLegacy Reserves Operating, LP

Bailey Dome - WY0027316HUC 10 - 1404020015

June 07, 2012Page 4 of 36

12. Provide the results of a water analyses for a sample collected from a location representative of the quality of water being proposed for discharge for the parameters listed below, in Table 2.

The analyses must be conducted in accordance with approved EPA test procedures (40 CFR Part 136). Include a signed

copy of your lab report that includes the following: a. detection limits b. results of each of the chemical parameters at the chemical state given below c. quarter/quarter, section, township and range of the sample collection location d. Time and date of sample collection e. Time and date of analysis for each parameter f. Detection limit for each parameter as achieved by the laboratory.

WYPDES Renewal ApplicationLegacy Reserves Operating, LP

Bailey Dome - WY0027316HUC 10 - 1404020015

June 07, 2012Page 5 of 36

*The values listed in the Standard or Limit column are associated with water quality standards (Chapter 1 of Wyoming Water Quality Rules and Regulations) or technology-based effluent limits (Chapter 2 of Wyoming Water Quality Rules and Regulations). **This parameter is only required for those discharges located within one stream mile of a class 2 water.

13. Which geologic formation is the origin of the produced water? Tensleep, Nugget

14. Were the above analyses collected from this facility (referenced in item 3)?

YES NO Sample collected from outfall 001.

If no, describe origin of samples including well name, location, depth, geologic formation, field, and date sample was analyzed:

TABLE 2

PARAMETER

REQUIRED DETECTION LIMIT and Required Units

STANDARD OR LIMIT* SAMPLE RESULTS (Also submit lab results with application)

Aluminum, Dissolved 50 ug/L 750 ug/L <0.03 mg/L

Arsenic, Total Recoverable 1 ug/L 150 ug/L <0.5 ug/L

Barium, Total Recoverable (New Facilities O l )

100 μg/L 2000 ug/L Not Applicable

Boron, Dissolved (New Facilities Only) 100 ug/L 5000 ug/L Not Applicable

Cadmium, Dissolved 5 ug/L 0.25 ug/L (hardness dep) <0.08 ug/L

Calcium, Dissolved 50 ug/L, report as mg/L 260 mg/L

Chloride – Technology Based 5 mg/L 2000 mg/L 630 mg/L

Chloride, For Class 2A and 2B Waters 5 mg/L 230 mg/L Not Applicable

Chromium, Dissolved (III) 1ug/L 74.1 ug/L (hardness d d )

<0.5 ug/L

Copper, Dissolved 10 ug/L 9 ug/L (hardness d d )

<0.5 ug/L

Fluoride, Dissolved (New Facilities Only) 100 ug/L 4,000 ug/L Not Applicable

Hardness (CaCO3) mg/L 10 mg/L as CaCO3 (for metals analyses) 780 mg/L

Iron, Dissolved 50 ug/L 1000 ug/L <0.02 mg/L

Iron, Dissolved, for Class 2A and 2AB waters 50 ug/L 300 ug/L Not Applicable

Lead, Dissolved 2 ug/L 2.5 ug/L (hardness dep) <0.1 ug/L

Magnesium, Dissolved 100 ug/L, report as mg/L 31 mg/L

Manganese, Dissolved 50 ug/L 1462 ug/L (hardness dep) <0.02 mg/L

Manganese, Dissolved, for Class 2A and 2AB t

50 ug/L 50 ug/L Not Applicable

Mercury, Dissolved 1 ug/L 0.77 ug/L <0.2 ug/L

Molybdenum, Dissolved (New Facilities Only) 100 ug/L 300 ug/L Not Applicable

Nickel, Dissolved 10 ug/L 52 ug/L (hardness dep) <0.5 ug/L

Oil and Grease 1 mg/L 10 mg/L 21 mg/L

pH 0.1 pH unit 6.5-9.0 s.u. 7.55 s.u.

Radium 226, Total Recoverable 0.2 pCi/L 5 or 60 pCi/L 0.7 pCi/L

Radium 228, Total Recoverable** 0.2 pCi/L 5 pCi/L Not Applicable

Selenium, Total Recoverable 5 ug/L 5 ug/L <0.5 ug/L

Silver, Dissolved 3 ug/L 3.4 ug/L (hardness dep) <0.5 ug/L

Sodium Adsorption Ratio Calculated as unadjusted ratio 12.6

Sodium, Dissolved 100 ug/L, report as mg/L 810 mg/L

Specific Conductance 5 micromhos/cm 7500 micromhos/cm 3850 micromhos/cm

Sulfates 10 mg/L 3000 mg/L 950 mg/L

Sulfide-Hydrogen Sulfide (S2-, HS-) 0.1 mg/L 2 ug/L 4300 ug/L

Total Dissolved Solids 5 mg/L 5000 mg/L 3300 mg/L

Total Petroleum Hydrocarbons 1 mg/L 28 mg/L

Zinc, Dissolved 50 ug/L 118.1 ug/L (hardness dep) 47.6 ug/L

WYPDES Renewal ApplicationLegacy Reserves Operating, LP

Bailey Dome - WY0027316HUC 10 - 1404020015

June 07, 2012Page 6 of 36

15. For new facilities, provide the expected (estimated) flow rate from each outfall in barrels per day and million gallons per day, and provide the rationale behind the flow rate estimate. Not applicable, this is an existing facility. Expected date of commencement of discharge. _________________________________ For existing facilities, provide actual flow data from each outfall within the last six months The actual maximum flow rate from this facility during July – December 2011 was 11,015 BPD and 0.463 MGD. Please see attached flow data table for details.

Will discharge be continuous or intermittent? If the discharge is to be intermittent the following information for each outfall shall be provided: (I) Number of times per year the discharge is to occur. (II) Anticipated duration of each discharge. (III) Anticipated flow of each discharge. (IV) Months in which discharge is expected to occur.

16. Are any of the required chemical constituents in the laboratory analysis present in concentrations above Wyoming Water Quality Standards or limits as identified in the third column in Table 2, page 5?

YES NO

If the answer to question # 16 is yes, answer 16a.–16.c below. If no, proceed to question 17.

a. Which constituents? Oil and Grease Sulfide-Hydrogen Sulfide b. Has this constituent been addressed in the response to question 10? Yes

c. Describe how the exceedance was addressed. The oil and grease value of 21 mg/L does not reflect historical data and may be due to sampling error. Please see attached lab result from 3/7/2012 for more typical results. Two (2) skimming ponds are also situated in a cascading fashion to help separate oil and grease and sulfide-hydrogen sulfide from discharging to waters of the state via outfall 001.

17. Will blending of fresh water with produced water be used as a treatment option?

YES NO If the answer to question # 17 is yes, answer 17a.–17.c below. If no, proceed to question 18.

a. What is the anticipated blending rate of fresh water and produced water? _________________________________ Be advised that permit will require water quantity and quality monitoring before and after blending occurs. Also, an automated shutdown system must be installed and maintained on site that terminates the discharge of produced water in the event of the shutdown of the fresh water supply.

b. Provide confirmation from the State Engineer’s office of fresh water use.

c. What is source of fresh water to be blended? No surface water source is allowed.

18. 40 CFR Part 435 Subpart E requires that the permittee document agricultural and wildlife uses of produced water. Provide

documentation that the produced water will be used for agriculture or wildlife during periods of discharge. Agriculture and wildlife use includes irrigation, livestock watering, wildlife watering, and other agricultural uses. Agricultural and wildlife use documentation includes (but is not limited to) a certified letter from a landowner(s), a formal written statement from a state, federal or local resource management agency, or a formal written statement with supporting documentation from a natural resources or environmental professional accompanied by the credentials of the natural resources or environmental professional. Agriculture and wildlife use documentation must be provided for each outfall included in the application.

WYPDES Renewal ApplicationLegacy Reserves Operating, LP

Bailey Dome - WY0027316HUC 10 - 1404020015

June 07, 2012Page 7 of 36

Agricultural and wildlife certification must be submitted for each outfall’s discharge, and must have original signatures.

Facilities permitted prior to June 10, 2002 are exempt from the above requirement. The Wyoming Game and Fish Department has determined that discharges of produced water from WYPDES-permitted oil production units in Wyoming, existing as of June 10, 2002, are being used to enhance wildlife propagation and habitat.

This facility was WYPDES or NPDES permitted prior to June 10, 2002 Documentation of beneficial use is enclosed

19. The applicant may submit any optional information the applicant wishes to have considered.

___________________________________________________________________________________________

WYPDES Renewal ApplicationLegacy Reserves Operating, LP

Bailey Dome - WY0027316HUC 10 - 1404020015

June 07, 2012Page 8 of 36

Authorized signatories for this application are the following:

For corporations: A principal executive officer of at least the level of vice president, or the manager of one or more manufacturing, production, or operating facilities, provided the manager is authorized to make management decisions which govern the overall operation of the facility from which the discharge originates.

For partnerships: A general partner.

For a sole proprietorship: The proprietor.

For a municipal, state, federal or other public facility:

Either a principal executive officer or ranking elected official.

I certify under penalty of law that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fine and imprisonment for knowing violations.

_Scott Bliss___________________________________ _Environmental Coordinator____________________ Printed Name of Person Signing Title _____________________________________________ _6/07/2012___________________________________

Signature of Applicant Date (307) 587-7232________________________________ (307) 527-4943________________________________ Telephone Fax

Section 35-11-901 of Wyoming Statutes provides that: *All permit applications must be signed in accordance with 40 CFR Part 122.22, “for” or “by” signatures are not acceptable. Section 35-11-901 of Wyoming Statutes provides that: Any person who knowingly makes any false statement, representation, or certification in any application ... shall upon conviction be fined not more than $10,000 or imprisoned for not more than one year, or both. Mail this application to: WYPDES Permits Section Department of Environmental Quality/WQD 122 West 25th Street, Herschler Building, 4W Cheyenne, WY 82002 Please include unique footer information on each page of this application and on all supporting documentation using the following format: Company Name: Year/Month/Day/NEW, MOD, RENEWAL/8Digit HUC Code/Permit # (if a modification or renewal) or Application # (from this particular company) for that particular day LIC/rm/12-0172

WYPDES Renewal ApplicationLegacy Reserves Operating, LP

Bailey Dome - WY0027316HUC 10 - 1404020015

June 07, 2012Page 9 of 36

sbliss
Stamp

Month *Total Facility Flow(BPD)

July 2011 9201August 2011 9479

September 2011 11015October 2011 10362

November 2011 10349December 2011 10349

11015

10125.830.425

0.4350.4350.435

0.463

* Total, Average, and Maximum Facility flows are based on actual discharge from outfall 001 during the months of July through December of 2011

Flow Data TableWY0027316 - Bailey Dome

*Average Facility Outfall Flow

*Maximum Facility Flow

*Total Facility Flow(MGD)0.3860.3980.463

WYPDES Renewal ApplicationLegacy Reserves Operating, LP

Bailey Dome - WY0027316HUC 10 - 1404020015

June 07, 2012Page 10 of 36

Lab ID: 12051708-01

Customer Sample ID: DP WY0027316 001

Matrix: Aqueous

Notes: Tracking ID: 208932

Customer Name: Legacy Reserves

Project ID: Bailey Dome

Order ID: 12051708

Report Date: 6/6/2012

LABORATORYANALYTICALREPORT

Analyses Method Analysis Date/Time AnalystResult Units RL Qual.

Collection: 5/16/2012

Received: 5/17/2012

1:20 PM

1:19 PM

Date Time

General ParametersRadium-226 0.7 +/- 0.5 pCi/L 0.21 SM 7500-Ra 5/25/2012 MW14:49

Total Hardness as CaCO3 780 mg/L 6.6 EPA 200.7 5/17/2012 EJ14:34

Major IonsCalcium 260 mg/L 2 EPA 200.7 5/17/2012 EJ14:34

Chloride 630 mg/L 100 EPA 300.0 5/22/2012 MW18:19

Fluoride 4.0 mg/L 0.2 EPA 300.0 5/22/2012 MW19:10

Sulfate 950 mg/L 100 EPA 300.0 5/22/2012 MW18:19

Physical PropertiesConductivity 3850 µS/cm 5 SM 2510 B 5/18/2012 KF12:27

pH 7.55 s.u. 0.01 EPA 150.1 5/18/2012 EJ11:14

Calcium (meq/L) 13.0 meq/L 0.1 Calculation 5/17/2012 EJ14:34

Magnesium (meq/L) 2.5 meq/L 0.1 Calculation 5/17/2012 EJ14:34

Sodium (meq/L) 35.1 meq/L 0.1 Calculation 5/17/2012 EJ14:34

Sodium Adsorption Ratio (SAR) 12.6 0.1 Calculation 5/17/2012 EJ14:34

Sulfide 4.3 mg/L 0.1 EPA 376.2 5/17/2012 MW15:58

Total Dissolved Solids (TDS) @ 180 C 3300 mg/L 5 SM 2540 C 5/1/2512 EF11:04

Total MetalsArsenic < 0.5 ug/L 0.5 L EPA 200.7 5/30/2012 CL21:52

Barium 1.22 mg/L 0.03 EPA 200.7 5/22/2012 HF14:39

Selenium < 0.5 ug/L 0.5 L EPA 1311 5/30/2012 CL21:52

Definitions:

ND-Not Detected at the reporting limit

RL-Analyte Reporting Limit

H-Holding times for preparation or analysis exceeded

S-Spike Recovery outside accepted recovery limits

M-Matrix Effect

J-Analyte detected below quantitation limits

D-Diluted out of recovery limits

L-Analyzed by a contract laboratory

Page 1 of 1Documentation will be kept for five (5) years.

WYPDES Renewal ApplicationLegacy Reserves Operating, LP

Bailey Dome - WY0027316HUC 10 - 1404020015

June 07, 2012Page 11 of 36

Jodi
Typewritten Text
Jodi
Typewritten Text
EPA 6020
Jodi
Typewritten Text
Jodi
Typewritten Text
EPA 6020
Jodi
Typewritten Text
Jodi
Typewritten Text

Lab ID: 12051708-01

Customer Sample ID: DP WY0027316 001

Matrix: Aqueous

Notes: Tracking ID: 208932

Customer Name: Legacy Reserves

Project ID: Bailey Dome

Order ID: 12051708

Report Date: 6/6/2012

LABORATORYANALYTICALREPORT

Analyses Method Analysis Date/Time AnalystResult Units RL Qual.

Collection: 5/16/2012

Received: 5/17/2012

1:20 PM

1:19 PM

Date Time

Dissolved MetalsAluminum < 0.03 mg/L 0.03 EPA 200.7 5/17/2012 EJ14:55

Boron 2.31 mg/L 0.04 EPA 200.7 5/17/2012 EJ14:55

Cadmium < 0.08 ug/L 0.08 L EPA 200.8 5/31/2012 CL12:45

Chromium < 0.5 ug/L 0.5 L EPA 200.8 5/31/2012 CL12:45

Copper < 0.5 ug/L 0.5 L EPA 200.8 5/31/2012 CL12:45

Iron < 0.02 mg/L 0.02 EPA 200.7 5/17/2012 EJ14:55

Lead < 0.1 ug/L 0.1 L EPA 200.7 5/31/2012 CL12:45

Magnesium 31 mg/L 0.2 EPA 200.7 5/17/2012 EJ14:45

Manganese < 0.02 mg/L 0.02 EPA 200.7 5/17/2012 EJ14:55

Mercury < 0.2 ug/L 0.2 L EPA 200.7 5/30/2012 CL18:29

Molybdenum < 0.04 mg/L 0.04 EPA 200.7 5/17/2012 EJ14:55

Nickel < 0.5 ug/L 0.5 L EPA 200.8 5/31/2012 CL12:45

Sodium 810 mg/L 3 EPA 200.7 5/17/2012 EJ14:34

Zinc 0.0476 mg/L 0.04 EPA 200.7 5/17/2012 EJ14:55

Definitions:

ND-Not Detected at the reporting limit

RL-Analyte Reporting Limit

H-Holding times for preparation or analysis exceeded

S-Spike Recovery outside accepted recovery limits

M-Matrix Effect

J-Analyte detected below quantitation limits

D-Diluted out of recovery limits

L-Analyzed by a contract laboratory

Page 1 of 1Documentation will be kept for five (5) years.

WYPDES Renewal ApplicationLegacy Reserves Operating, LP

Bailey Dome - WY0027316HUC 10 - 1404020015

June 07, 2012Page 12 of 36

Jodi
Typewritten Text
EPA 6020
Jodi
Typewritten Text
Jodi
Typewritten Text
EPA 6020
Jodi
Typewritten Text
EPA 6020
Jodi
Typewritten Text
Jodi
Typewritten Text
EPA 6020
Jodi
Typewritten Text
Jodi
Typewritten Text
EPA 7470
Jodi
Typewritten Text
EPA 6020
Jodi
Typewritten Text
Jodi
Typewritten Text
Silver <0.5 ug/L 0.5 L EPA 6020 5/31/2012 12:45 CL
Jodi
Typewritten Text
Jodi
Typewritten Text
Jodi
Typewritten Text
Jodi
Typewritten Text
Jodi
Typewritten Text
Jodi
Typewritten Text
Jodi
Typewritten Text
Jodi
Typewritten Text
Jodi
Typewritten Text
Jodi
Typewritten Text

Lab ID: 12051708-01

Customer Sample ID: DP WY0027316 001

Matrix: Aqueous

Notes: Tracking ID: 208932

Customer Name: Legacy Reserves

Project ID: Bailey Dome

Order ID: 12051708

Report Date: 6/6/2012

LABORATORYANALYTICALREPORT

Analyses Method Analysis Date/Time AnalystResult Units RL Qual.

Collection: 5/16/2012

Received: 5/17/2012

1:20 PM

1:19 PM

Date Time

Organic CompoundsGasoline Range Organics (GRO) 5900 ug/L 100 EPA 8015 D 5/23/2012 RH17:52

4-Bromofluorobenzene (FID)Surr: 98.0 % 70-130 EPA 8015 D

Diesel Range Organics (DRO) 22 mg/L 5 EPA 8015 D 5/24/2012 RH4:10o-TerphenylSurr: 217.6 % 70-130 EPA 8015 DM, D

Oil and Grease 21 mg/L 1 EPA 1664 A 5/21/2012 JP13:30

TPH as DRO + GRO 28 mg/L 0.1 Calculation 5/23/2012 RH17:52

Definitions:

ND-Not Detected at the reporting limit

RL-Analyte Reporting Limit

H-Holding times for preparation or analysis exceeded

S-Spike Recovery outside accepted recovery limits

M-Matrix Effect

J-Analyte detected below quantitation limits

D-Diluted out of recovery limits

L-Analyzed by a contract laboratory

Page 1 of 1Documentation will be kept for five (5) years.

WYPDES Renewal ApplicationLegacy Reserves Operating, LP

Bailey Dome - WY0027316HUC 10 - 1404020015

June 07, 2012Page 13 of 36

LaboratoryAnalyticalReportCustomer Name: Legacy Reserves

Project ID: Bailey Dome

Order ID: 12031202

Report Date: 3/20/2012

Analyses Method Analysis Date/Time AnalystResult Units RL

Lab Sample ID: 12031202-01

Collection: 3/7/2012

Received: 3/12/2012

Customer Sample ID: DP WY0027316 001

Matrix: Aqueous

Qual.

3:05 PM

4:20 AM

Date Time

Notes: Tracking #: 204181

Total Petroleum Hydrocarbons (HEM) EPA 1664 A JP6.5 mg/L 1 3/19/2012 10:00:00 AM

Definitions:

ND-Not Detected at the reporting limit

RL-Analyte Reporting Limit

H-Holding times for preparation or analysis exceeded

S-Spike Recovery outside accepted recovery limits

M-Matrix Effect

J-Analyte detected below quantitation limits

D-Diluted out of recovery limits

L-Analyzed by a contract laboratory

Page 1 of 1Documentation will be kept for five (5) years.WYPDES Renewal ApplicationLegacy Reserves Operating, LP

Bailey Dome - WY0027316HUC 10 - 1404020015

June 07, 2012Page 14 of 36

kort
Typewritten Text
Oil & Grease (HEM)
kort
Typewritten Text
kort
Typewritten Text

MATERIAL SAFETY DATA SHEET PRODUCT

EC6033A

EMERGENCY TELEPHONE NUMBER(S) (800) 424-9300 (24 Hours) CHEMTREC

Nalco Energy Services, L.P. P.O. Box 87 • Sugar Land, Texas 77487-0087

(281)263-7000 1 / 10

1. CHEMICAL PRODUCT AND COMPANY IDENTIFICATION PRODUCT NAME : EC6033A APPLICATION : WATER CLARIFIER COMPANY IDENTIFICATION : Nalco Energy Services, L.P. P.O. Box 87 Sugar Land, Texas 77487-0087 EMERGENCY TELEPHONE NUMBER(S) : (800) 424-9300 (24 Hours) CHEMTREC NFPA 704M/HMIS RATING HEALTH : 3 / 3 FLAMMABILITY : 3 / 3 INSTABILITY : 0 / 0 OTHER : 0 = Insignificant 1 = Slight 2 = Moderate 3 = High 4 = Extreme 2. COMPOSITION/INFORMATION ON INGREDIENTS Our hazard evaluation has identified the following chemical substance(s) as hazardous. Consult Section 15 for the nature of the hazard(s).

Hazardous Substance(s) CAS NO % (w/w) Zinc Chloride 7646-85-7 30.0 - 60.0 Isopropanol 67-63-0 5.0 - 10.0 3. HAZARDS IDENTIFICATION

**EMERGENCY OVERVIEW**

DANGER Flammable. Corrosive. May cause tissue damage. Do not get in eyes, on skin, on clothing. Do not take internally. Avoid breathing vapor. Use with adequate ventilation. Keep container tightly closed. Keep away from heat. Keep away from sources of ignition - No smoking. In case of contact with eyes, rinse immediately with plenty of water and seek medical advice. After contact with skin, wash immediately with plenty of water. Wear a face shield. Wear suitable protective clothing, gloves and eye/face protection. Flammable Liquid; may release vapors that form flammable mixtures at or above the flash point. Empty product containers may contain product residue. Do not pressurize, cut, heat, weld, or expose containers to flame or other sources of ignition. May evolve oxides of carbon (COx) under fire conditions. May evolve oxides of nitrogen (NOx) under fire conditions. PRIMARY ROUTES OF EXPOSURE : Eye, Skin

WYPDES Renewal ApplicationLegacy Reserves Operating, LP

Bailey Dome - WY0027316HUC 10 - 1404020015

June 07, 2012Page 15 of 36

MATERIAL SAFETY DATA SHEET PRODUCT

EC6033A

EMERGENCY TELEPHONE NUMBER(S) (800) 424-9300 (24 Hours) CHEMTREC

Nalco Energy Services, L.P. P.O. Box 87 • Sugar Land, Texas 77487-0087

(281)263-7000 2 / 10

HUMAN HEALTH HAZARDS - ACUTE : EYE CONTACT : Corrosive. Will cause eye burns and permanent tissue damage. SKIN CONTACT : May cause severe irritation or tissue damage depending on the length of exposure and the type of first aid administered. INGESTION : Not a likely route of exposure. Corrosive, causes burns to gastro-intestinal tract. Nausea, vomiting and stomach pain may occur. In severe cases blood may be vomited. INHALATION : Irritating to the eyes, nose, throat and lungs. SYMPTOMS OF EXPOSURE : Acute : A review of available data does not identify any symptoms from exposure not previously mentioned. Chronic : A review of available data does not identify any symptoms from exposure not previously mentioned. AGGRAVATION OF EXISTING CONDITIONS : A review of available data does not identify any worsening of existing conditions. 4. FIRST AID MEASURES EYE CONTACT : PROMPT ACTION IS ESSENTIAL IN CASE OF CONTACT. Immediately flush eye with water for at least 15 minutes while holding eyelids open. Get immediate medical attention. SKIN CONTACT : Immediately flush with plenty of water for at least 15 minutes. For a large splash, flood body under a shower. Remove contaminated clothing. Wash off affected area immediately with plenty of water. Get immediate medical attention. Contaminated clothing, shoes, and leather goods must be discarded or cleaned before re-use. INGESTION : DO NOT INDUCE VOMITING. If conscious, washout mouth and give water to drink. Get medical attention. INHALATION : Remove to fresh air, treat symptomatically. Get medical attention. NOTE TO PHYSICIAN : Probable mucosal damage may contraindicate the use of gastric lavage. Based on the individual reactions of the patient, the physician's judgement should be used to control symptoms and clinical condition.

WYPDES Renewal ApplicationLegacy Reserves Operating, LP

Bailey Dome - WY0027316HUC 10 - 1404020015

June 07, 2012Page 16 of 36

MATERIAL SAFETY DATA SHEET PRODUCT

EC6033A

EMERGENCY TELEPHONE NUMBER(S) (800) 424-9300 (24 Hours) CHEMTREC

Nalco Energy Services, L.P. P.O. Box 87 • Sugar Land, Texas 77487-0087

(281)263-7000 3 / 10

5. FIRE FIGHTING MEASURES FLASH POINT : 83 °F / 28.3 °C ( PMCC ) EXTINGUISHING MEDIA : Alcohol foam, Carbon dioxide, Dry powder, Other extinguishing agent suitable for Class B fires, For large fires, use water spray or fog, thoroughly drenching the burning material. Keep containers cool by spraying with water. FIRE AND EXPLOSION HAZARD : Flammable Liquid; may release vapors that form flammable mixtures at or above the flash point. Empty product containers may contain product residue. Do not pressurize, cut, heat, weld, or expose containers to flame or other sources of ignition. May evolve oxides of carbon (COx) under fire conditions. May evolve oxides of nitrogen (NOx) under fire conditions. SPECIAL PROTECTIVE EQUIPMENT FOR FIRE FIGHTING : In case of fire, wear a full face positive-pressure self contained breathing apparatus and protective suit. 6. ACCIDENTAL RELEASE MEASURES PERSONAL PRECAUTIONS : Restrict access to area as appropriate until clean-up operations are complete. Ensure clean-up is conducted by trained personnel only. Ventilate spill area if possible. Do not touch spilled material. Remove sources of ignition. Stop or reduce any leaks if it is safe to do so. Use personal protective equipment recommended in Section 8 (Exposure Controls/Personal Protection). Notify appropriate government, occupational health and safety and environmental authorities. METHODS FOR CLEANING UP : SMALL SPILLS: Soak up spill with absorbent material. Place residues in a suitable, covered, properly labeled container. Wash affected area. LARGE SPILLS: Contain liquid using absorbent material, by digging trenches or by diking. Reclaim into recovery or salvage drums or tank truck for proper disposal. Wash site of spillage thoroughly with water. Contact an approved waste hauler for disposal of contaminated recovered material. Dispose of material in compliance with regulations indicated in Section 13 (Disposal Considerations). ENVIRONMENTAL PRECAUTIONS : Prevent material from entering sewers or waterways. 7. HANDLING AND STORAGE HANDLING : Avoid eye and skin contact. Do not take internally. Do not breathe vapors/gases/dust. Do not get in eyes, on skin, on clothing. Have emergency equipment (for fires, spills, leaks, etc.) readily available. Ensure all containers are labelled. Keep the containers closed when not in use. Use with adequate ventilation. Do not use in locations where vapor is likely to travel to welding flames or arcs or to other hot surfaces. Vapors are much heavier than air, this can result in uneven distribution.

WYPDES Renewal ApplicationLegacy Reserves Operating, LP

Bailey Dome - WY0027316HUC 10 - 1404020015

June 07, 2012Page 17 of 36

MATERIAL SAFETY DATA SHEET PRODUCT

EC6033A

EMERGENCY TELEPHONE NUMBER(S) (800) 424-9300 (24 Hours) CHEMTREC

Nalco Energy Services, L.P. P.O. Box 87 • Sugar Land, Texas 77487-0087

(281)263-7000 4 / 10

STORAGE CONDITIONS : Store the containers tightly closed. Store in suitable labelled containers. Store away from heat and sources of ignition. Store separately from oxidizers. Have appropriate fire extinguishers available in and near the storage area. 8. EXPOSURE CONTROLS/PERSONAL PROTECTION OCCUPATIONAL EXPOSURE LIMITS : Exposure guidelines have not been established for this product. Available exposure limits for the substance(s) are shown below. ACGIH/TLV : Substance(s) Zinc Chloride Fume TWA: 1 mg/m3

STEL: 2 mg/m3

Isopropanol TWA: 400 ppm , 983 mg/m3 STEL: 500 ppm , 1,230 mg/m3

OSHA/PEL : Substance(s) Zinc Chloride Fume TWA: 1 mg/m3

STEL: 2 mg/m3

Isopropanol TWA: 400 ppm , 980 mg/m3 STEL: 500 ppm , 1,225 mg/m3

ENGINEERING MEASURES : Use general ventilation with local exhaust ventilation. RESPIRATORY PROTECTION : If significant mists, vapors or aerosols are generated an approved respirator is recommended. Wear an organic vapor/mist respirator when spraying. In event of emergency or planned entry into unknown concentrations a positive pressure, full-facepiece SCBA should be used. If respiratory protection is required, institute a complete respiratory protection program including selection, fit testing, training, maintenance and inspection. HAND PROTECTION : PVC OR NITRILE GLOVES SKIN PROTECTION : Wear chemical resistant apron, chemical splash goggles, impervious gloves and boots. A full slicker suit is recommended if gross exposure is possible. EYE PROTECTION : Wear a face shield with chemical splash goggles. HYGIENE RECOMMENDATIONS : Eye wash station and safety shower are necessary. If clothing is contaminated, remove clothing and thoroughly wash the affected area. Launder contaminated clothing before reuse.

WYPDES Renewal ApplicationLegacy Reserves Operating, LP

Bailey Dome - WY0027316HUC 10 - 1404020015

June 07, 2012Page 18 of 36

MATERIAL SAFETY DATA SHEET PRODUCT

EC6033A

EMERGENCY TELEPHONE NUMBER(S) (800) 424-9300 (24 Hours) CHEMTREC

Nalco Energy Services, L.P. P.O. Box 87 • Sugar Land, Texas 77487-0087

(281)263-7000 5 / 10

HUMAN EXPOSURE CHARACTERIZATION : Based on our recommended product application and personal protective equipment, the potential human exposure is: Moderate 9. PHYSICAL AND CHEMICAL PROPERTIES PHYSICAL STATE Liquid APPEARANCE Cloudy Amber ODOR Alcoholic SPECIFIC GRAVITY 1.31 @ 60 °F / SOLUBILITY IN WATER Complete pH () 3.4 VISCOSITY 20 cps @ 60 °F / VISCOSITY 16 cst @ 60 °F / VISCOSITY 79 SUS @ 60 °F / VAPOR PRESSURE 69 mm Hg @ 100 °F / Note: These physical properties are typical values for this product and are subject to change. 10. STABILITY AND REACTIVITY STABILITY : Stable under normal conditions. HAZARDOUS POLYMERIZATION : Hazardous polymerization will not occur. CONDITIONS TO AVOID : Heat and sources of ignition including static discharges. MATERIALS TO AVOID : Contact with strong oxidizers (e.g. chlorine, peroxides, chromates, nitric acid, perchlorate, concentrated oxygen, permanganate) may generate heat, fires, explosions and/or toxic vapors. HAZARDOUS DECOMPOSITION PRODUCTS : Under fire conditions: Oxides of carbon 11. TOXICOLOGICAL INFORMATION No toxicity studies have been conducted on this product.

WYPDES Renewal ApplicationLegacy Reserves Operating, LP

Bailey Dome - WY0027316HUC 10 - 1404020015

June 07, 2012Page 19 of 36

MATERIAL SAFETY DATA SHEET PRODUCT

EC6033A

EMERGENCY TELEPHONE NUMBER(S) (800) 424-9300 (24 Hours) CHEMTREC

Nalco Energy Services, L.P. P.O. Box 87 • Sugar Land, Texas 77487-0087

(281)263-7000 6 / 10

CARCINOGENICITY : None of the substances in this product are listed as carcinogens by the International Agency for Research on Cancer (IARC), the National Toxicology Program (NTP) or the American Conference of Governmental Industrial Hygienists (ACGIH). HUMAN HAZARD CHARACTERIZATION : Based on our hazard characterization, the potential human hazard is: High 12. ECOLOGICAL INFORMATION ECOTOXICOLOGICAL EFFECTS : No toxicity studies have been conducted on this product. ENVIRONMENTAL HAZARD AND EXPOSURE CHARACTERIZATION Based on our hazard characterization, the potential environmental hazard is: High Based on our recommended product application and the product's characteristics, the potential environmental exposure is: High If released into the environment, see CERCLA/SUPERFUND in Section 15. 13. DISPOSAL CONSIDERATIONS If this product becomes a waste, it could meet the criteria of a hazardous waste as defined by the Resource Conservation and Recovery Act (RCRA) 40 CFR 261. Before disposal, it should be determined if the waste meets the criteria of a hazardous waste. Hazardous Waste: D001 Hazardous wastes must be transported by a licensed hazardous waste transporter and disposed of or treated in a properly licensed hazardous waste treatment, storage, disposal or recycling facility. Consult local, state, and federal regulations for specific requirements. 14. TRANSPORT INFORMATION The information in this section is for reference only and should not take the place of a shipping paper (bill of lading) specific to an order. Please note that the proper Shipping Name / Hazard Class may vary by packaging, properties, and mode of transportation. Typical Proper Shipping Names for this product are as follows. LAND TRANSPORT :

Proper Shipping Name : FLAMMABLE LIQUID, CORROSIVE, N.O.S. Technical Name(s) : ISOPROPANOL, ZINC CHLORIDE UN/ID No : UN 2924 Hazard Class - Primary : 3 Hazard Class - Secondary : 8 Packing Group : III

WYPDES Renewal ApplicationLegacy Reserves Operating, LP

Bailey Dome - WY0027316HUC 10 - 1404020015

June 07, 2012Page 20 of 36

MATERIAL SAFETY DATA SHEET PRODUCT

EC6033A

EMERGENCY TELEPHONE NUMBER(S) (800) 424-9300 (24 Hours) CHEMTREC

Nalco Energy Services, L.P. P.O. Box 87 • Sugar Land, Texas 77487-0087

(281)263-7000 7 / 10

Flash Point : 28.3 °C / 83 °F

DOT Reportable Quantity (per package) : 2,900 lbs DOT RQ Component : ZINC CHLORIDE

AIR TRANSPORT (ICAO/IATA) :

Proper Shipping Name : FLAMMABLE LIQUID, CORROSIVE, N.O.S. Technical Name(s) : ISOPROPANOL, ZINC CHLORIDE UN/ID No : UN 2924 Hazard Class - Primary : 3 Hazard Class - Secondary : 8 Packing Group : III IATA Cargo Packing Instructions : 310 IATA Cargo Aircraft Limit : 60 L (Max net quantity per package)

MARINE TRANSPORT (IMDG/IMO) :

Proper Shipping Name : FLAMMABLE LIQUID, CORROSIVE, N.O.S. Technical Name(s) : ISOPROPANOL, ZINC CHLORIDE UN/ID No : UN 2924 Hazard Class - Primary : 3 Hazard Class - Secondary : 8 Packing Group : III

15. REGULATORY INFORMATION NATIONAL REGULATIONS, USA : OSHA HAZARD COMMUNICATION RULE, 29 CFR 1910.1200 : Based on our hazard evaluation, the following substance(s) in this product is/are hazardous and the reason(s) is/are shown below. Zinc Chloride : Corrosive Isopropanol : Flammable, Eye irritant CERCLA/SUPERFUND, 40 CFR 117, 302 : This product contains the following Reportable Quantity (RQ) Substance. Also listed is the RQ for the product. SARA/SUPERFUND AMENDMENTS AND REAUTHORIZATION ACT OF 1986 (TITLE III) - SECTIONS 302, 311, 312, AND 313 : SECTION 302 - EXTREMELY HAZARDOUS SUBSTANCES (40 CFR 355) : This product does not contain substances listed in Appendix A and B as an Extremely Hazardous Substance. SECTIONS 311 AND 312 - MATERIAL SAFETY DATA SHEET REQUIREMENTS (40 CFR 370) : Our hazard evaluation has found this product to be hazardous. The product should be reported under the following indicated EPA hazard categories:

WYPDES Renewal ApplicationLegacy Reserves Operating, LP

Bailey Dome - WY0027316HUC 10 - 1404020015

June 07, 2012Page 21 of 36

MATERIAL SAFETY DATA SHEET PRODUCT

EC6033A

EMERGENCY TELEPHONE NUMBER(S) (800) 424-9300 (24 Hours) CHEMTREC

Nalco Energy Services, L.P. P.O. Box 87 • Sugar Land, Texas 77487-0087

(281)263-7000 8 / 10

X Immediate (Acute) Health Hazard - Delayed (Chronic) Health Hazard X Fire Hazard - Sudden Release of Pressure Hazard - Reactive Hazard

Under SARA 311 and 312, the EPA has established threshold quantities for the reporting of hazardous chemicals. The current thresholds are: 500 pounds or the threshold planning quantity (TPQ), whichever is lower, for extremely hazardous substances and 10,000 pounds for all other hazardous chemicals. SECTION 313 - LIST OF TOXIC CHEMICALS (40 CFR 372) : This product contains the following substance(s), (with CAS # and % range) which appear(s) on the List of Toxic Chemicals

Hazardous Substance(s) CAS NO % (w/w) Zinc Chloride 7646-85-7 30.0 - 60.0 Isopropanol 67-63-0 5.0 - 10.0

TOXIC SUBSTANCES CONTROL ACT (TSCA) : The substances in this preparation are included on or exempted from the TSCA 8(b) Inventory (40 CFR 710) FEDERAL WATER POLLUTION CONTROL ACT, CLEAN WATER ACT, 40 CFR 401.15 / formerly Sec. 307, 40 CFR 116.4 / formerly Sec. 311 : This product contains the following substances listed in the regulation:

Substance(s) Citations • Zinc Chloride

Sec. 307, Sec. 311

CLEAN AIR ACT, Sec. 111 (40 CFR 60, Volatile Organic Compounds), Sec. 112 (40 CFR 61, Hazardous Air Pollutants), Sec. 602 (40 CFR 82, Class I and II Ozone Depleting Substances) : This product contains the following substances listed in the regulation:

Substance(s) Citations • Isopropanol

Sec. 111

CALIFORNIA PROPOSITION 65 : This product does not contain substances which require warning under California Proposition 65. MICHIGAN CRITICAL MATERIALS : This product contains the following substances listed in the regulation:

Zinc Chloride STATE RIGHT TO KNOW LAWS : The following substances are disclosed for compliance with State Right to Know Laws:

Zinc Chloride 7646-85-7

WYPDES Renewal ApplicationLegacy Reserves Operating, LP

Bailey Dome - WY0027316HUC 10 - 1404020015

June 07, 2012Page 22 of 36

MATERIAL SAFETY DATA SHEET PRODUCT

EC6033A

EMERGENCY TELEPHONE NUMBER(S) (800) 424-9300 (24 Hours) CHEMTREC

Nalco Energy Services, L.P. P.O. Box 87 • Sugar Land, Texas 77487-0087

(281)263-7000 9 / 10

Isopropanol 67-63-0 NATIONAL REGULATIONS, CANADA : WORKPLACE HAZARDOUS MATERIALS INFORMATION SYSTEM (WHMIS) : This product has been classified in accordance with the hazard criteria of the Controlled Products Regulations (CPR) and the MSDS contains all the information required by the CPR. WHMIS CLASSIFICATION : B2 - Flammable Liquids, E - Corrosive Material CANADIAN ENVIRONMENTAL PROTECTION ACT (CEPA) : The substances in this preparation are listed on the Domestic Substances List (DSL), are exempt, or have been reported in accordance with the New Substances Notification Regulations. 16. OTHER INFORMATION Due to our commitment to Product Stewardship, we have evaluated the human and environmental hazards and exposures of this product. Based on our recommended use of this product, we have characterized the product's general risk. This information should provide assistance for your own risk management practices. We have evaluated our product's risk as follows: * The human risk is: Moderate * The environmental risk is: High Any use inconsistent with our recommendations may affect the risk characterization. Our sales representative will assist you to determine if your product application is consistent with our recommendations. Together we can implement an appropriate risk management process. This product material safety data sheet provides health and safety information. The product is to be used in applications consistent with our product literature. Individuals handling this product should be informed of the recommended safety precautions and should have access to this information. For any other uses, exposures should be evaluated so that appropriate handling practices and training programs can be established to insure safe workplace operations. Please consult your local sales representative for any further information.

REFERENCES Threshold Limit Values for Chemical Substances and Physical Agents and Biological Exposure Indices, American Conference of Governmental Industrial Hygienists, OH., (Ariel Insight# CD-ROM Version), Ariel Research Corp., Bethesda, MD. Hazardous Substances Data Bank, National Library of Medicine, Bethesda, Maryland (TOMES CPS# CD-ROM Version), Micromedex, Inc., Englewood, CO. IARC Monographs on the Evaluation of the Carcinogenic Risk of Chemicals to Man, Geneva: World Health Organization, International Agency for Research on Cancer.

WYPDES Renewal ApplicationLegacy Reserves Operating, LP

Bailey Dome - WY0027316HUC 10 - 1404020015

June 07, 2012Page 23 of 36

MATERIAL SAFETY DATA SHEET PRODUCT

EC6033A

EMERGENCY TELEPHONE NUMBER(S) (800) 424-9300 (24 Hours) CHEMTREC

Nalco Energy Services, L.P. P.O. Box 87 • Sugar Land, Texas 77487-0087

(281)263-7000 10 / 10

Integrated Risk Information System, U.S. Environmental Protection Agency, Washington, D.C. (TOMES CPS# CD-ROM Version), Micromedex, Inc., Englewood, CO. Annual Report on Carcinogens, National Toxicology Program, U.S. Department of Health and Human Services, Public Health Service. Title 29 Code of Federal Regulations, Part 1910, Subpart Z, Toxic and Hazardous Substances, Occupational Safety and Health Administration (OSHA), (Ariel Insight# CD-ROM Version), Ariel Research Corp., Bethesda, MD. Registry of Toxic Effects of Chemical Substances, National Institute for Occupational Safety and Health, Cincinnati, OH, (TOMES CPS# CD-ROM Version), Micromedex, Inc., Englewood, CO. Ariel Insight# (An integrated guide to industrial chemicals covered under major regulatory and advisory programs), North American Module, Western European Module, Chemical Inventories Module and the Generics Module (Ariel Insight# CD-ROM Version), Ariel Research Corp., Bethesda, MD. The Teratogen Information System, University of Washington, Seattle, WA (TOMES CPS# CD-ROM Version), Micromedex, Inc., Englewood, CO. Prepared By : Product Safety Department Date issued : 02/20/2004 Version Number : 1.3

WYPDES Renewal ApplicationLegacy Reserves Operating, LP

Bailey Dome - WY0027316HUC 10 - 1404020015

June 07, 2012Page 24 of 36

SAFETY DATA SHEET PRODUCT

EC6031A

EMERGENCY TELEPHONE NUMBER(S) (800) 424-9300 (24 Hours) CHEMTREC

Nalco Company 1601 W. Diehl Road • Naperville, Illinois 60563-1198 • (630)305-1000

For additional copies of an MSDS visit www.nalco.com and request access 1 / 10

1. CHEMICAL PRODUCT AND COMPANY IDENTIFICATION PRODUCT NAME : EC6031A APPLICATION : WATER CLARIFIER COMPANY IDENTIFICATION : Nalco Company 1601 W. Diehl Road Naperville, Illinois 60563-1198 EMERGENCY TELEPHONE NUMBER(S) : (800) 424-9300 (24 Hours) CHEMTREC NFPA 704M/HMIS RATING HEALTH : 3 / 3 FLAMMABILITY : 0 / 0 INSTABILITY : 0 / 0 OTHER : 0 = Insignificant 1 = Slight 2 = Moderate 3 = High 4 = Extreme * = Chronic Health Hazard 2. COMPOSITION/INFORMATION ON INGREDIENTS Our hazard evaluation has identified the following chemical substance(s) as hazardous. Consult Section 15 for the nature of the hazard(s).

Hazardous Substance(s) CAS NO % (w/w) Zinc Chloride 7646-85-7 30.0 - 60.0 Quaternary polyamine Proprietary 10.0 - 30.0 3. HAZARDS IDENTIFICATION

**EMERGENCY OVERVIEW**

DANGER Corrosive. May cause irritation with prolonged contact. Irritating to respiratory system. Harmful if swallowed. Do not get in eyes, on skin, on clothing. Do not take internally. Use with adequate ventilation. In case of contact with eyes, rinse immediately with plenty of water and seek medical advice. After contact with skin, wash immediately with plenty of water. Use a mild soap if available. Wear a face shield. Wear chemical resistant apron, chemical splash goggles, impervious gloves and boots. Not flammable or combustible. May evolve oxides of carbon (COx) under fire conditions. May evolve oxides of nitrogen (NOx) under fire conditions. May evolve zinc fumes under fire conditions. PRIMARY ROUTES OF EXPOSURE : Eye, Skin HUMAN HEALTH HAZARDS - ACUTE : EYE CONTACT : Corrosive. Will cause eye burns and permanent tissue damage.

WYPDES Renewal ApplicationLegacy Reserves Operating, LP

Bailey Dome - WY0027316HUC 10 - 1404020015

June 07, 2012Page 25 of 36

SAFETY DATA SHEET PRODUCT

EC6031A

EMERGENCY TELEPHONE NUMBER(S) (800) 424-9300 (24 Hours) CHEMTREC

Nalco Company 1601 W. Diehl Road • Naperville, Illinois 60563-1198 • (630)305-1000

For additional copies of an MSDS visit www.nalco.com and request access 2 / 10

SKIN CONTACT : Corrosive; causes permanent skin damage. INGESTION : Not a likely route of exposure. Corrosive; causes chemical burns to the mouth, throat and stomach. Harmful if swallowed. INHALATION : Not a likely route of exposure. Elevated temperatures or mechanical action may form vapors, mists or fumes which may be irritating to the eyes, nose, throat and lungs. AGGRAVATION OF EXISTING CONDITIONS : A review of available data does not identify any worsening of existing conditions. 4. FIRST AID MEASURES EYE CONTACT : Immediately flush eye with water for at least 15 minutes while holding eyelids open. PROMPT ACTION IS ESSENTIAL IN CASE OF CONTACT. Get immediate medical attention. SKIN CONTACT : Immediately flush with plenty of water for at least 15 minutes. Use a mild soap if available. For a large splash, flood body under a shower. Get immediate medical attention. Contaminated clothing, shoes, and leather goods must be discarded or cleaned before re-use. INGESTION : Get immediate medical attention. DO NOT INDUCE VOMITING. If conscious, washout mouth and give water to drink. INHALATION : Remove to fresh air, treat symptomatically. Get immediate medical attention. NOTE TO PHYSICIAN : Probable mucosal damage may contraindicate the use of gastric lavage. Based on the individual reactions of the patient, the physician's judgement should be used to control symptoms and clinical condition. 5. FIRE FIGHTING MEASURES FLASH POINT : None EXTINGUISHING MEDIA : This product would not be expected to burn unless all the water is boiled away. The remaining organics may be ignitable. Use extinguishing media appropriate for surrounding fire. Water mist may be used to cool closed containers. FIRE AND EXPLOSION HAZARD : Not flammable or combustible. May evolve oxides of carbon (COx) under fire conditions. May evolve oxides of nitrogen (NOx) under fire conditions. May evolve zinc fumes under fire conditions.

WYPDES Renewal ApplicationLegacy Reserves Operating, LP

Bailey Dome - WY0027316HUC 10 - 1404020015

June 07, 2012Page 26 of 36

SAFETY DATA SHEET PRODUCT

EC6031A

EMERGENCY TELEPHONE NUMBER(S) (800) 424-9300 (24 Hours) CHEMTREC

Nalco Company 1601 W. Diehl Road • Naperville, Illinois 60563-1198 • (630)305-1000

For additional copies of an MSDS visit www.nalco.com and request access 3 / 10

SPECIAL PROTECTIVE EQUIPMENT FOR FIRE FIGHTING : In case of fire, wear a full face positive-pressure self contained breathing apparatus and protective suit. 6. ACCIDENTAL RELEASE MEASURES PERSONAL PRECAUTIONS : Restrict access to area as appropriate until clean-up operations are complete. Use personal protective equipment recommended in Section 8 (Exposure Controls/Personal Protection). Stop or reduce any leaks if it is safe to do so. Keep people away from and upwind of spill/leak. Ventilate spill area if possible. Ensure clean-up is conducted by trained personnel only. Do not touch spilled material. Have emergency equipment (for fires, spills, leaks, etc.) readily available. Notify appropriate government, occupational health and safety and environmental authorities. METHODS FOR CLEANING UP : SMALL SPILLS: Soak up spill with absorbent material. Place residues in a suitable, covered, properly labeled container. Wash affected area. LARGE SPILLS: Contain liquid using absorbent material, by digging trenches or by diking. Reclaim into recovery or salvage drums or tank truck for proper disposal. Wash site of spillage thoroughly with water. Contact an approved waste hauler for disposal of contaminated recovered material. Dispose of material in compliance with regulations indicated in Section 13 (Disposal Considerations). ENVIRONMENTAL PRECAUTIONS : Very toxic to aquatic organisms, may cause long-term adverse effects in the aquatic environment., Prevent material from entering sewers or waterways., If drains, streams, soil or sewers become contaminated, notify local authority. 7. HANDLING AND STORAGE HANDLING : Do not get in eyes, on skin, on clothing. Do not take internally. Use with adequate ventilation. Avoid generating aerosols and mists. Keep the containers closed when not in use. Have emergency equipment (for fires, spills, leaks, etc.) readily available. Ensure all containers are labeled. STORAGE CONDITIONS : Store the containers tightly closed. Store separately from oxidizers. Store in suitable labeled containers. SUITABLE CONSTRUCTION MATERIAL : Compatibility with Plastic Materials can vary; we therefore recommend that compatibility is tested prior to use. 8. EXPOSURE CONTROLS/PERSONAL PROTECTION OCCUPATIONAL EXPOSURE LIMITS : Exposure guidelines have not been established for this product. Available exposure limits for the substance(s) are shown below. Substance(s) Category: ppm mg/m3 Non-Standard

Unit Zinc Chloride (Fume) ACGIH/TWA 1 ACGIH/STEL 2 OSHA Z1/PEL 1

WYPDES Renewal ApplicationLegacy Reserves Operating, LP

Bailey Dome - WY0027316HUC 10 - 1404020015

June 07, 2012Page 27 of 36

SAFETY DATA SHEET PRODUCT

EC6031A

EMERGENCY TELEPHONE NUMBER(S) (800) 424-9300 (24 Hours) CHEMTREC

Nalco Company 1601 W. Diehl Road • Naperville, Illinois 60563-1198 • (630)305-1000

For additional copies of an MSDS visit www.nalco.com and request access 4 / 10

ENGINEERING MEASURES : General ventilation is recommended. Use local exhaust ventilation if necessary to control airborne mist and vapor. RESPIRATORY PROTECTION : Where concentrations in air may exceed the limits given in this section or when significant mists, vapors, aerosols, or dusts are generated, an approved air purifying respirator equipped with suitable filter cartridges is recommended. Consult the respirator / cartridge manufacturer data to verify the suitability of specific devices. In event of emergency or planned entry into unknown concentrations a positive pressure, full-facepiece SCBA should be used. If respiratory protection is required, institute a complete respiratory protection program including selection, fit testing, training, maintenance and inspection. HAND PROTECTION : When handling this product, the use of chemical gauntlets is recommended. The choice of work glove depends on work conditions and what chemicals are handled. Please contact the PPE manufacturer for advice on what type of glove material may be suitable. Gloves should be replaced immediately if signs of degradation are observed. SKIN PROTECTION : Wear chemical resistant apron, chemical splash goggles, impervious gloves and boots. A full slicker suit is recommended if gross exposure is possible. EYE PROTECTION : Wear a face shield with chemical splash goggles. HYGIENE RECOMMENDATIONS : Use good work and personal hygiene practices to avoid exposure. Eye wash station and safety shower are necessary. If clothing is contaminated, remove clothing and thoroughly wash the affected area. Launder contaminated clothing before reuse. Always wash thoroughly after handling chemicals. When handling this product never eat, drink or smoke. HUMAN EXPOSURE CHARACTERIZATION : Based on our recommended product application and personal protective equipment, the potential human exposure is: Low 9. PHYSICAL AND CHEMICAL PROPERTIES PHYSICAL STATE Liquid APPEARANCE Brown ODOR Musty SPECIFIC GRAVITY 1.39 - 1.43 @ 61 °F / 16 °C SOLUBILITY IN WATER Dispersible pH (100 %) 1.4 - 2.5 VISCOSITY 28 cst @ 60 °F / 15 °C POUR POINT -30 °F / -34 °C

WYPDES Renewal ApplicationLegacy Reserves Operating, LP

Bailey Dome - WY0027316HUC 10 - 1404020015

June 07, 2012Page 28 of 36

SAFETY DATA SHEET PRODUCT

EC6031A

EMERGENCY TELEPHONE NUMBER(S) (800) 424-9300 (24 Hours) CHEMTREC

Nalco Company 1601 W. Diehl Road • Naperville, Illinois 60563-1198 • (630)305-1000

For additional copies of an MSDS visit www.nalco.com and request access 5 / 10

Note: These physical properties are typical values for this product and are subject to change. 10. STABILITY AND REACTIVITY STABILITY : Stable under normal conditions. HAZARDOUS POLYMERIZATION : Hazardous polymerization will not occur. CONDITIONS TO AVOID : Extremes of temperature MATERIALS TO AVOID : Contact with strong oxidizers (e.g. chlorine, peroxides, chromates, nitric acid, perchlorate, concentrated oxygen, permanganate) may generate heat, fires, explosions and/or toxic vapors. HAZARDOUS DECOMPOSITION PRODUCTS : Under fire conditions: Oxides of carbon, Oxides of nitrogen, Zinc Oxide 11. TOXICOLOGICAL INFORMATION The following results are for the product. ACUTE ORAL TOXICITY : Species: Rat LD50: 1,449 mg/kg Test Descriptor: Product ACUTE DERMAL TOXICITY : Species: Rabbit LD50: 3,038 mg/kg Test Descriptor: Product PRIMARY SKIN IRRITATION : Species: Rabbit Draize Score: 6.3 /8.0 Test Descriptor: Product PRIMARY EYE IRRITATION : Species: Rabbit Draize Score: 102 /110.0 Test Descriptor: Product

WYPDES Renewal ApplicationLegacy Reserves Operating, LP

Bailey Dome - WY0027316HUC 10 - 1404020015

June 07, 2012Page 29 of 36

SAFETY DATA SHEET PRODUCT

EC6031A

EMERGENCY TELEPHONE NUMBER(S) (800) 424-9300 (24 Hours) CHEMTREC

Nalco Company 1601 W. Diehl Road • Naperville, Illinois 60563-1198 • (630)305-1000

For additional copies of an MSDS visit www.nalco.com and request access 6 / 10

CARCINOGENICITY : None of the substances in this product are listed as carcinogens by the International Agency for Research on Cancer (IARC), the National Toxicology Program (NTP) or the American Conference of Governmental Industrial Hygienists (ACGIH). HUMAN HAZARD CHARACTERIZATION : Based on our hazard characterization, the potential human hazard is: High 12. ECOLOGICAL INFORMATION ECOTOXICOLOGICAL EFFECTS : No toxicity studies have been conducted on this product. ENVIRONMENTAL HAZARD AND EXPOSURE CHARACTERIZATION Based on our hazard characterization, the potential environmental hazard is: High Based on our recommended product application and the product's characteristics, the potential environmental exposure is: High If released into the environment, see CERCLA/SUPERFUND in Section 15. 13. DISPOSAL CONSIDERATIONS If this product becomes a waste, it could meet the criteria of a hazardous waste as defined by the Resource Conservation and Recovery Act (RCRA) 40 CFR 261. Before disposal, it should be determined if the waste meets the criteria of a hazardous waste. Hazardous Waste: D002 Hazardous wastes must be transported by a licensed hazardous waste transporter and disposed of or treated in a properly licensed hazardous waste treatment, storage, disposal or recycling facility. Consult local, state, and federal regulations for specific requirements. 14. TRANSPORT INFORMATION The information in this section is for reference only and should not take the place of a shipping paper (bill of lading) specific to an order. Please note that the proper Shipping Name / Hazard Class may vary by packaging, properties, and mode of transportation. Typical Proper Shipping Names for this product are as follows. The presence of an RQ component (Reportable Quantity for U.S. EPA and DOT) in this product causes it to be regulated with an additional description of RQ for road, or as a class 9 for road and air, ONLY when the net weight in the package exceeds the calculated RQ for the product. LAND TRANSPORT :

Proper Shipping Name : ZINC CHLORIDE, SOLUTION Technical Name(s) : UN/ID No : UN 1840

WYPDES Renewal ApplicationLegacy Reserves Operating, LP

Bailey Dome - WY0027316HUC 10 - 1404020015

June 07, 2012Page 30 of 36

SAFETY DATA SHEET PRODUCT

EC6031A

EMERGENCY TELEPHONE NUMBER(S) (800) 424-9300 (24 Hours) CHEMTREC

Nalco Company 1601 W. Diehl Road • Naperville, Illinois 60563-1198 • (630)305-1000

For additional copies of an MSDS visit www.nalco.com and request access 7 / 10

Hazard Class - Primary : 8 Packing Group : III Flash Point : None Reportable Quantity (per package) : 2,800 lbs RQ Component : ZINC CHLORIDE

AIR TRANSPORT (ICAO/IATA) : The presence of an RQ component (Reportable Quantity for U.S. EPA and DOT) in this product causes it to be regulated with an additional description of RQ for road, or as a class 9 for road and air, ONLY when the net weight in the package exceeds the calculated RQ for the product.

Proper Shipping Name : ZINC CHLORIDE, SOLUTION Technical Name(s) : UN/ID No : UN 1840 Hazard Class - Primary : 8 Packing Group : III Reportable Quantity (per package) : 2,800 lbs RQ Component : ZINC CHLORIDE

MARINE TRANSPORT (IMDG/IMO) :

Proper Shipping Name : ZINC CHLORIDE, SOLUTION Technical Name(s) : UN/ID No : UN 1840 Hazard Class - Primary : 8 Packing Group : III

*Marine Pollutant : ZINC CHLORIDE

*Note: This product is regulated as a Marine Pollutant when shipped by Rail, Highway, or Air in bulk quantities (greater than 119 gallons) and when shipped by water in all quantities. 15. REGULATORY INFORMATION This section contains additional information that may have relevance to regulatory compliance. The information in this section is for reference only. It is not exhaustive, and should not be relied upon to take the place of an individualized compliance or hazard assessment. Nalco accepts no liability for the use of this information. NATIONAL REGULATIONS, USA : OSHA HAZARD COMMUNICATION RULE, 29 CFR 1910.1200 : Based on our hazard evaluation, the following substance(s) in this product is/are hazardous and the reason(s) is/are shown below. Zinc Chloride : Corrosive Quaternary polyamine : Eye irritant

WYPDES Renewal ApplicationLegacy Reserves Operating, LP

Bailey Dome - WY0027316HUC 10 - 1404020015

June 07, 2012Page 31 of 36

SAFETY DATA SHEET PRODUCT

EC6031A

EMERGENCY TELEPHONE NUMBER(S) (800) 424-9300 (24 Hours) CHEMTREC

Nalco Company 1601 W. Diehl Road • Naperville, Illinois 60563-1198 • (630)305-1000

For additional copies of an MSDS visit www.nalco.com and request access 8 / 10

CERCLA/SUPERFUND, 40 CFR 302 : This product contains the following Reportable Quantity (RQ) Substance. Also listed is the RQ for the product.

RQ Substance RQ Zinc Chloride 2,800 lbs

SARA/SUPERFUND AMENDMENTS AND REAUTHORIZATION ACT OF 1986 (TITLE III) - SECTIONS 302, 311, 312, AND 313 : SECTION 302 - EXTREMELY HAZARDOUS SUBSTANCES (40 CFR 355) : This product does not contain substances listed in Appendix A and B as an Extremely Hazardous Substance. SECTIONS 311 AND 312 - MATERIAL SAFETY DATA SHEET REQUIREMENTS (40 CFR 370) : Our hazard evaluation has found this product to be hazardous. The product should be reported under the following indicated EPA hazard categories:

X Immediate (Acute) Health Hazard - Delayed (Chronic) Health Hazard - Fire Hazard - Sudden Release of Pressure Hazard - Reactive Hazard

Under SARA 311 and 312, the EPA has established threshold quantities for the reporting of hazardous chemicals. The current thresholds are: 500 pounds or the threshold planning quantity (TPQ), whichever is lower, for extremely hazardous substances and 10,000 pounds for all other hazardous chemicals. SECTION 313 - LIST OF TOXIC CHEMICALS (40 CFR 372) : This product contains the following substance(s), (with CAS # and % range) which appear(s) on the List of Toxic Chemicals

Hazardous Substance(s) CAS NO % (w/w) Zinc Chloride 7646-85-7 30.0 - 60.0

TOXIC SUBSTANCES CONTROL ACT (TSCA) : The substances in this preparation are included on or exempted from the TSCA 8(b) Inventory (40 CFR 710) FEDERAL WATER POLLUTION CONTROL ACT, CLEAN WATER ACT, 40 CFR 401.15 / formerly Sec. 307, 40 CFR 116.4 / formerly Sec. 311 : This product contains the following substances listed in the regulation. Additional components may be unintentionally present at trace levels.

Substance(s) Citations • Zinc Chloride

Sec. 307, Sec. 311

CLEAN AIR ACT, Sec. 112 (Hazardous Air Pollutants, as amended by 40 CFR 63), Sec. 602 (40 CFR 82, Class I and II Ozone Depleting Substances) : Substances listed under this regulation are not intentionally added or expected to be present in this product. Listed components may be present at trace levels.

WYPDES Renewal ApplicationLegacy Reserves Operating, LP

Bailey Dome - WY0027316HUC 10 - 1404020015

June 07, 2012Page 32 of 36

SAFETY DATA SHEET PRODUCT

EC6031A

EMERGENCY TELEPHONE NUMBER(S) (800) 424-9300 (24 Hours) CHEMTREC

Nalco Company 1601 W. Diehl Road • Naperville, Illinois 60563-1198 • (630)305-1000

For additional copies of an MSDS visit www.nalco.com and request access 9 / 10

CALIFORNIA PROPOSITION 65 : Substances listed under California Proposition 65 are not intentionally added or expected to be present in this product. MICHIGAN CRITICAL MATERIALS : This product contains the following substances listed in the regulation. Additional components may be unintentionally present at trace levels.

Zinc Chloride STATE RIGHT TO KNOW LAWS : The following substances are disclosed for compliance with State Right to Know Laws:

Zinc Chloride 7646-85-7 INTERNATIONAL CHEMICAL CONTROL LAWS : CANADIAN ENVIRONMENTAL PROTECTION ACT (CEPA) : The substance(s) in this preparation are included in or exempted from the Domestic Substance List (DSL). 16. OTHER INFORMATION Due to our commitment to Product Stewardship, we have evaluated the human and environmental hazards and exposures of this product. Based on our recommended use of this product, we have characterized the product's general risk. This information should provide assistance for your own risk management practices. We have evaluated our product's risk as follows: * The human risk is: Low * The environmental risk is: High Any use inconsistent with our recommendations may affect the risk characterization. Our sales representative will assist you to determine if your product application is consistent with our recommendations. Together we can implement an appropriate risk management process. This product material safety data sheet provides health and safety information. The product is to be used in applications consistent with our product literature. Individuals handling this product should be informed of the recommended safety precautions and should have access to this information. For any other uses, exposures should be evaluated so that appropriate handling practices and training programs can be established to insure safe workplace operations. Please consult your local sales representative for any further information.

REFERENCES Threshold Limit Values for Chemical Substances and Physical Agents and Biological Exposure Indices, American Conference of Governmental Industrial Hygienists, OH., (Ariel Insight™ CD-ROM Version), Ariel Research Corp., Bethesda, MD.

WYPDES Renewal ApplicationLegacy Reserves Operating, LP

Bailey Dome - WY0027316HUC 10 - 1404020015

June 07, 2012Page 33 of 36

SAFETY DATA SHEET PRODUCT

EC6031A

EMERGENCY TELEPHONE NUMBER(S) (800) 424-9300 (24 Hours) CHEMTREC

Nalco Company 1601 W. Diehl Road • Naperville, Illinois 60563-1198 • (630)305-1000

For additional copies of an MSDS visit www.nalco.com and request access 10 / 10

Hazardous Substances Data Bank, National Library of Medicine, Bethesda, Maryland (TOMES CPS™ CD-ROM Version), Micromedex, Inc., Englewood, CO. IARC Monographs on the Evaluation of the Carcinogenic Risk of Chemicals to Man, Geneva: World Health Organization, International Agency for Research on Cancer. Integrated Risk Information System, U.S. Environmental Protection Agency, Washington, D.C. (TOMES CPS™ CD-ROM Version), Micromedex, Inc., Englewood, CO. Annual Report on Carcinogens, National Toxicology Program, U.S. Department of Health and Human Services, Public Health Service. Title 29 Code of Federal Regulations, Part 1910, Subpart Z, Toxic and Hazardous Substances, Occupational Safety and Health Administration (OSHA), (Ariel Insight™ CD-ROM Version), Ariel Research Corp., Bethesda, MD. Registry of Toxic Effects of Chemical Substances, National Institute for Occupational Safety and Health, Cincinnati, OH, (TOMES CPS™ CD-ROM Version), Micromedex, Inc., Englewood, CO. Ariel Insight™ (An integrated guide to industrial chemicals covered under major regulatory and advisory programs), North American Module, Western European Module, Chemical Inventories Module and the Generics Module (Ariel Insight™ CD-ROM Version), Ariel Research Corp., Bethesda, MD. The Teratogen Information System, University of Washington, Seattle, WA (TOMES CPS™ CD-ROM Version), Micromedex, Inc., Englewood, CO. Prepared By : Product Safety Department Date issued : 01/10/2011 Version Number : 2.0

WYPDES Renewal ApplicationLegacy Reserves Operating, LP

Bailey Dome - WY0027316HUC 10 - 1404020015

June 07, 2012Page 34 of 36

Access to Pad

ProducedWater

Pit

ProducedWater

Pit

SkimTanks

1000 bblsOil500 bbls

Oil400bbls

Pump

67' x 47' x 2.5'

Building

Kno

ckou

t(N

ot in

Ser

vice

)

PropaneN

ugge

tS

epar

ator

Dehydrator

Transformers

Methanoltank 11.9 bbls

Propane

HeaderBuilding

2.4 bblsEmulsionBreaker

Bldg

Tens

leep

Sep

arat

or

Tens

leep

Kno

ckou

t

Nug

get

Kno

ckou

t

Bldg

2 Unknown1.3 bbls drums

2 Corrosion Inhibitor

1.3 bbls drums

Demulsifier1.3 bbls drum

Nugget LACT(Not in Service)

ElectricalPanel

ExtraEquipment

Area

Berm Height = 2.3 Feet

99'

55'

Gat

e

Inte

rTec

h E

&E

, LLC

kand

ers@

cbm

ainc

.com

M:\P

roje

cts\

Lega

cy\B

aile

y_D

ome\

DW

G\B

aile

yD

ome

Dis

char

ge W

Y00

2731

6-00

1 20

1205

23.d

wg

Exp

lana

tion:

NE

NE

Sec

21

TW

N 2

6N -

RN

G 8

9W

Ear

then

Ber

mFe

ncin

g

1. T

he b

erm

leng

th, w

idth

, and

hei

ght a

re th

e m

inim

um b

erm

dim

ensi

ons

requ

ired

to c

onta

in th

e la

rges

t tan

k vo

lum

e pl

us fr

eebo

ard

for a

25

year

24

hour

pre

cipi

tatio

n ev

ent.

2. E

quip

men

t con

nect

ions

are

sho

wn

for p

roce

ss d

irect

ion

only

and

are

not

are

flect

ion

of a

s-pi

ped

cond

ition

s in

the

field

.D

ate

May

31,

201

2S

cale

Not

to S

cale

Not

es

Oil500 bbls

Oil400bbls

Oil400bbls

32' x 18' x 2.0'

52' x 67' x 2'

Lega

cy R

eser

ves

Ope

ratin

g, L

PB

aile

y D

ome

Dis

char

geW

Y00

2731

6-00

1

Slope

From All BaileyDome Wells

Slop Tank400 bbls(Not in

Service)

Pipe andEquipment

Pipe andEquipment

Oil400bbls

Load OutFor Tensleep

Load OutFor Nugget

SkimTanks

1000 bbls

Water

Water

Oil

Oil

Bailey Dome DischargeWYPDES PermitWY0027316-001

Load Out

Ç*Ç*

Ç*

Ç*

Ç*

Ç*_

798

11

18

19

30

15

27 26 25

202221

24

29 28

17

23

1614

10

Bailey Dome 8

Bailey Dome 4

Bailey Dome 3Bailey Dome 1

Bailey Dome Unit

Bailey Dome C-065693 10

US 287

WY 789

WY 73

T26N R89W001

293000

293000

294000

294000

295000

295000

296000

296000

297000

297000

298000

298000

299000

299000

300000

300000

4674

000

4674

000

4675

000

4675

000

4676

000

4676

000

4677

000

4677

000

4678

000

4678

000

4679

000

4679

000

InterTech E&E, [email protected]

M:\Projects\Legacy\Bailey_Dome\Projects\WY0027316_PR_20120508.mxd

Bailey DomeWYPDESRenewal

WY0027316HUC 10 - 1404020015

May 8, 2012

Ç*Ç*Ç*Ç*Ç*Ç*_

Muddy Creek

Carbon

Sweetwater

Fremont

Boggy MeadowsHUC1404020015

Bairoil

0 0.5 1Miles

Ü1:24,000

Explanation_ Outfall - Constructed

Ç* Well - Federal

Ç* Well - State

Wyoming County Roads

Interstate Highway

State/Fed Highway

DetailBoundary

T27NT26N

T26NT25N

R90W | R89W R89W | R88W