R.E SB CV

5
Engr. Ghulam Abbas Cell: +923317119697, +923477772208 Email:[email protected] OBJECTIVE: ___________ _______________________________________________ To work in power organization that offers a management, creative, dynamic and professional environment. Where abilities can be utilized fully to achieve goals and to utilize experience worth’s. QUALIFICATION B.Sc. Electrical Engineering Professional Engineer PEC # ELECT/19757 Experience: _ 9+Years___________________________________________________ 1year as Assistant Engineer (O&M) 7 Years as Assistant Engineer (P&I) NTDCL Pakistan. 1year to date as Resident Engineer 500KV NTDCL (WAPDA) Pakistan. Trainings:______________________________________________________________ 32 weeks P&I training from TSG Terbela and Lahore. 15 weeks Management Training (WAPDA Staff College Islamabad). 15 weeks Technical Training (Grid Station). 03 weeks PLC training.

description

LL

Transcript of R.E SB CV

Page 1: R.E SB CV

Engr. Ghulam Abbas

Cell: +923317119697, +923477772208

Email:[email protected]

OBJECTIVE: ___________ _______________________________________________

To work in power organization that offers a management, creative, dynamic and

professional environment. Where abilities can be utilized fully to achieve goals and to

utilize experience worth’s.

QUALIFICATION

B.Sc. Electrical Engineering

Professional Engineer PEC # ELECT/19757

Experience: _ 9+Years___________________________________________________

1year as Assistant Engineer (O&M)

7 Years as Assistant Engineer (P&I) NTDCL Pakistan.

1year to date as Resident Engineer 500KV NTDCL (WAPDA) Pakistan.

Trainings:______________________________________________________________

32 weeks P&I training from TSG Terbela and Lahore.

15 weeks Management Training (WAPDA Staff College Islamabad).

15 weeks Technical Training (Grid Station).

03 weeks PLC training.

Page 2: R.E SB CV

National Transmission and dispatch company (NTDCL) PAKISTAN_____________

Position 1: Assistant Engineer P&I at 500KV G/S Multan.

Period: 01/2004 to 12/2011 (7 Years).

Position 2: Deputy Manager (Resident Engineer) 500KV Grid Station Multan.

Period: 01/2012 to date

Expertise as Protection Engineer.___________________________________________

1. Commissioning/installation/testing of all kinds of protection Schemes & control

schemes designed by TOSHIBA, GE, ALSTOM, SIEMENS, ABB, MG of

600MVA 500/220KV,450MVA 500/220KV, 160MVA 220/132KV Auto

Transformers ABB,TBEA,SIEMNS,TOSHIBA,JSHP make and 500KV,220KV

& 132KV Transmission Lines, 500KV&220KV Bus Bar used in NATIONAL

TRANSMISSION AND DESPATCH COMPANY LIMITED (NTDCL)

PAKISTAN

Having hands on Experience to designed/Modified the Breaker failure

Protection Scheme and 220KV BUS BARS 1&2 Protection Scheme

during Extension of 220KVGrid at 500KV Multan.

Having hands on Experience to Test/Modify the Control Circuit, Tripping

Circuit, AC & DC Circuits, CT Circuits, CCVT/CVT, PT Circuits and

Trip Circuit Supervision of Auto Transformers and Transmission Lines,

shunt reactors and bus bars schemes.

Have an Experience to test Temperature Gauges (Winding), CT circuit of

Transformer, Shunt Reactors etc.

Have an experience to Test Wiring of AC/DC (220 ,110 Volts )Supply

Distribution to Control Panels, Relay Panels Marshaling Kiosk and Circuit

Breakers / Isolators & Transformers /Shunt Reactor Cubical Box etc.

Have an Experience of commissioning 220V DC Battery Charger in

addition.

Have good experience of CT Circuit and rectified many times faults in the

CT circuit of Differential/Distance Protective Relays at 500KV G/S

Multan.

Page 3: R.E SB CV

2. Experience & Knowledge of Troubleshooting and root cause analysis of faults in

control circuits, CT & CCVT/CVT circuits and tripping circuits of AUTO

Transformers, Transmission Lines, BUS BARS schemes.

Have a Sound experience and knowledge about the faults related with

control circuits of Auto transformers, Bus bar , Shunt Reactors and

Transmission Lines Circuit Breakers.

Having hands on Experience about the faults related to CCVT/CVT circuit

of Distance Protective relay, Over Voltage relay installed at transmission

lines.

Troubleshoot the tripping circuits of Auto Transformers, Power

Transformers & transmission lines in case of failure of one of the main

protection installed at these equipment.

3. Testing/Commissioning/Installation of different type of protective relays of

TOSHIBA, GE, ALSTOM, SIEMENS & ABB Make for AUTO Transformers,

Shunt Reactors, and BUS BAR and Transmission lines with Universal Testing

Sets and relevant software.

Having hands on Experience of installation /commissioning /Testing of

following Protective Relays.

SrNO. Nomenclature of relays Type of relay Make

01 Differential T6o GE

02 Distance D60 GE

03 Breaker Failure C60 GE

04 Over Load/Over Current MFII GE

05 Distance OPTIMHO LZF11 ALSTOM

06 LOW Impedance MBCZ ALSTOM

Bus Bar

07 MICROMHO SHNB102 GEC

Quadramho SHPM GEC

08 Over Current MCGG, MCAG GEC

09 Over Voltage MVTU, MVTD GEC

10 Biased Differential MBCH GEC

Page 4: R.E SB CV

SrNO. Nomenclature of relays Type of relay Make

11 Breaker Failure MCTI GEC

12 Distance 7SA52 SIEMENS

13 Differential 7UT612 SIEMENS

14 Distance 7SA513 SIEMENS

15 Over Current 7SJ6000 SIEMENS

16 Distance LZ96, LZ96a ABB

17 Over Voltage UT91 ABB

18 Differential TBB7B TOSHIBA

19 Differential GBT4D TOSHIBA

Having hands on Experience of using following testing sets

SrNO. Type of Testing Set Make

01 FREJA MEGGER

02 F6150 DOBLE

03 C&DF M2HE DOBLE

04 PRIMARY INJECTION AG POWER

PT-3000

05 SECONDRY INJECTION AG POWER

MICRO TEST 860

06 TTR TEST SET DV POWER

TRT30D

07 Transformer Winding Resistance

Test Set WRM-10

08 Battery Impedance Test Set ENERVEK

BITE2

09 SF6 Gas Purity Test Set DILLO

10 TM1600

11 SF6 Gas Dew Point Meter DILLO

12 5KV MEGGER TEST MEGGER

13 AC HI-POT 130KV PROGRAMA

14 DC HI-POT 160KV BIDDLE

15 ZFB Distance Relay Test Set GEC

Page 5: R.E SB CV

4. Complete Testing of EHV&HV Substation Equipments such as Current Transformer,

Potential Transformer, Auto Transformers, and Capacitor Voltage Transformer &

Coupling Capacitor Voltage Transformer. Testing of Ear thing Mesh and HT cables etc.

Computer Skills

MS Office, Window XP, Metering Software, Relays software (DIGSI, ENERVISTA,

OPTICOM)

Other Skills

Communication ENGLISH, URDU

Personal Information_____________________________________________________

Name Ghulam Abbas

Father Name Khan Muhammad

Date &Place of Birth 10 /DEC /1977, Multan Pakistan

Marital Status Married

No of Dependents 05

Passport No AU1017922

NIC No 36102-0986792-7

References______________________________________________________________

Provided if demanded