RDM monitoring WECS II 512 - oase-professional.com
Transcript of RDM monitoring WECS II 512 - oase-professional.com
The DMX patchgrid gives an overview of channel allocation and the DMX channel value output. The cable con-figuration of shows can be controlled and modified via Drag&Drop.
DMX patchgrid
The WECS II hardware is able to exchange data with the WEPS-RDM-monitor. So it can write, for example, DMX addresses in the devices or read out sensor data and other device-specific parameters. RDM (Remote Device Management) capable devi-ces are listed. These can be linked to the particular „Assemblies“ with Drag&Drop.
RDM monitoring
WECS II 512WECS II 1024
Water Entertainment Control System
DMX/RDM
OASE GmbH · Postfach 20 69 · 48469 HörstelTelefon: +49 5454 80-0 · Fax: +49 5454 80-9253 · [email protected] · www.oase-livingwater.com 32
628/
05G
SF
The
prod
ucts
show
n/of
fere
d ar
e de
signe
d ex
clusiv
ely f
or th
e de
scrib
ed p
urpo
se. If
the
prod
ucts
we
have
cite
d ar
e us
ed in
appr
opria
tely,
we
assu
me
no li
abili
ty w
hats
oeve
r for
def
ects
or d
amag
e th
at o
ccur
s due
to th
is cir
cum
stan
ce.
Te
xt a
nd im
age
desc
riptio
ns d
o no
t con
stitu
te a
ny a
ssur
ance
s of c
hara
cter
istics
. Min
or d
evia
tions
in o
ur p
rodu
cts d
o no
t con
stitu
te a
def
ect.
Use
of o
ur im
age
data
is o
nly p
erm
itted
afte
r obt
aini
ng p
rior w
ritte
n ap
prov
al fr
om O
ASE.
Hardware
512 channel RDM/DMX output ∞ ∞
1024 channel RDM/DMX output ∞
Easy to use front panel setup ∞ ∞
Interface 1024 channel ∞ ∞
8 digital output ∞ ∞
8 digital input ∞ ∞
DIN rail housing ∞ ∞
Audio output ∞
Stand aloneStand alone capable ∞ ∞
Stand alone micro SD card 4GB ∞ ∞
Show upload via micro SD card ∞ ∞
Stand alone calendar ∞ ∞
Connectivity Ethernet RJ45 10/100 Mbit ∞ ∞
Order no. 56491 56492
Software
Fixture library ∞ ∞
Pachting ∞ ∞
Operating & monitoring (Live page) ∞ ∞
RDM monitoring ∞ ∞
Logbook files ∞ ∞
Scene ∞ ∞
Sequences ∞ ∞
Scheduler ∞ ∞
DMX channel preview ∞ ∞
Effects: SIN, COS, RECT, SAW UP/-DOWN ∞ ∞
Matrix programming ∞ ∞
Time schedule with internal clock ∞ ∞
Media support audio ∞
WECS II 512/DMX/02 WECS II 1024/DMX/02
WECS II overview
A Any number of shows or sequences for a project can be saved on the micro SD card (4GB included).B RJ-45 EthernetC Audio 3,5 mm stereo jack, galvanically isolatedD Connection of vollage supply +24V DC for digital outputs (-/+)E 8x digital output 1A/output, galvanically isolatedF 4x connection to power supply (++/--) 15-24 V DC /8WG 2x DMX-RDM outputs, galvanically isolated H 2x grounding for digital inputs I 8x digital inputs, galvanically isolated
A B C D E
IHGF
The new generation WECS II controller is capable of bi-directional (DMX-RDM) communication. The fanless controller transmits DMX-RDM data packets to the individual components (lights, pumps, DMX-RDM controllable nozzles, motion etc.) which enable them to act accordingly. These components or devices in turn analyse the received data and send back their status signals like operating hours and temperature via the same cable. These status signals enable remote diagnosis and remote maintenance of the connected components.
All digital outputs can be used to switch relays and frequency converters directly. The digital inputs can be linked to water level sensors or external push buttons. That enables to control shows and faders from outside. Further-more, as a special feature, the OASE Wind Anemometer drives the internal wind-fader directly to control fountain heights according to the wind speed.
The WECS II 512/DMX/02 is a standalone Entertainment-Controller for 512 DMX/RDM-channels. On the other hand the WECS II 1024/DMX/02 is the new music standalone Entertainment-Controller for 1024 DMX/RDM-channels with audio file.
Remote diagnosis and remote maintenance enables to provide better and faster service to customers.
WECS II 512 WECS II 1024
The sequencer is a real time player. Lighting scenes, pump scenes, moving elements can be recorded in real time and dropped on the sequencer timeline. The easy handling of the real time show visualizer provides an effortless way to integrate the complete multimedia show. Furthermore, a sequence can be started via the external inputs or the scheduler.
User friendly Sequencer
Take full control of your shows from your Windows® tablet. A quick start of the individual shows is possible from a PC or Windows® tablet.
Microsoft and Windows are either registered trademarks of Microsoft Corporation in the United States and/or other countries.
Live page
RoUtER
With the WECS II (Water Entertainment Control System) fountain shows can be freely programmed and played synchronously to the music in a desired time schedule accurately to the second. The Software WEPS (Water Entertainment Programming Software) comes as standard with the WECS II.The WEPS software can be downloaded free of cost and a visualized fountain show can be pre-programmed with it (registration to OASE Dealer Portal required).
http://www.oase-livingwater.com/en_EN/service/download/
The WEPS-software is suitable for creating shows for small and mid-size systems. A visual overview of the system configuration enables creating different water pictures and scenes in an optical style. These can be used individually as basis for the show. The control data can be sent in real time to a connected „OASE WECS II“ system enabling „Live“ control of a show system. The finished arrangement can be played back directly from the hardware or automatically via its scheduler.
WEPS softwareWater Entertainment Control System
Full DMX RDM Output 512 channels
Water show unit standalone
Real time show visualizer
WECS II 512
Full DMX RDM Output 1024 channels
Water show unit standalone with audio
Real time show visualizer
WECS II 1024
SchedulerThis software provides a combination of different schedulers for the automation of all processes. By the combination of daily planners, weekly planners and annual planners, it is possible to design a huge number of automatedprocesses.
One software for both WECS II systems.
Programmer
Patching Single fixtures are pooled spatially to assemblies. An assembly can also consist of a single component (e.g. a pump). Afterwards, these assemblies can be moved and arranged optionally at the top view of the fixture. An advantage of this working method, for example,would be in creating a matrix. Located at the spatial point is the pump as well as the RGBW spot and allother accessories such as the nozzle type and other small items. These single fixtures can be pooled in one assembly and later positioned spatially.
The programmer has a huge number of possibilities for creating different effects.
Static scenes: In static scenes, a timely constant value can be assignedto an assembly selection in selected channels.
Dynamic scenes: A dynamic scene consists of a static scene with a further delay. The delay is splitted equally under selected assemblies and sorted in the order of selection. A static effect which can be used for all selected assemblies is started in order of election. By this, the gained water picture receives an effective dynamic.
Effect scenes: An effect scene consists of a static scene with overlayed andmathematical time function (e.g. sinus, rectangle, saw tooth ). Effect sceneschanges its value depending on time.
All three scene types can be combined in one scene.
DMX/RDM
www
SERvICE