STRUCTURAL ENGINEERING is a consultancy firm founded in Santiago, Chile in2001. The firm is managed by Raul Campos Q., Structural Engineer and Msc. Seismic Engineering at the University of Chile. (C)

With 12 years of experience, the firm provides the managing and design of structural projects in areas such as: road infrastructure, industry, mining, and energy. We can give consultancy from the conceptual stage to the construction stage.

One of the main areas developed has been the road infrastructure. So far, we have designed over 150.000 m2 of bridge deck equivalent to 40.000 linear meters. The associated investment has been over 215 million dollars, which included over 10 major viaducts and railways, and some of them were designed with seismic isolation. Our main goal is to promote and develop “joint less” bridges typology.

Our design philosophy has been the constant learning about the latest technologies in seismic protection of structures, which has allowed us to provide safe and reliable infrastructure to the community.

The firm provides stable support by 3 structural engineers, 3 structural designers, human resource and management. We have created a partners network, which allows us to provide consulting in areas such as: geotechnical, geomechanics, hydrology, road design, architecture, instrumentation, virtual modeling (render), and virtual animation (video)

RCQF I R M P R O F I L E

Page 7: Rcq ingenieria estructural  2013

N U E S T R A E M P R E S A

INGENIERIA ESTRUCTURAL es una empresa de Consultoria en Ingenieria Estructural, fundada en Santiago de Chile en el año 2001. la empresa se encuentra liderada por Raul Campos Q., Ingeniero Civil Estructural y MSC. de

la Universidad de Chile (E).

Con 12 años de experiencia, la empresa ofrece la gestion y desarrollo de proyectos de ingenieria estructural en diversas areas tales como: infraestructura vial, industria, mineria y energia. lo anterior abarca desde analisis conceptuales hasta la asesoria durante la etapa de construccion.

Una de las areas mas destacadas corresponde a infraestructura vial, en la cual hemos proyectado a la fecha mas de 150.000 m2 de puentes, equivalentes a mas de 40.000 metros lineales, y que ha implicado una inversion superior a los 215 millones de dolares. lo anterior incluye el diseño de 10 viaductos carreteros y de metro, algunos de los cuales incorporan aislacion y/o proteccion sismica. nuestra linea de trabajo en materias de infraestructura vial, es promover el uso y desarrollo de la tipologia de puentes sin juntas o “jointless” bridges.

Piedraangulardenuestrafilosofiadediseño,eslaconstanteincorporaciondelasultimastecnicas de proteccion sismica de estructuras, lo cual nos permite entregar a la comunidad infraestructuraconfiable.

La empresa cuenta con una planta estable de 3 ingenieros civiles estructurales, 3 proyectistas estructurales, y personal administrativo. ademas, hemos creado una red de colaboradores que nos permiten entregar asesoria y desarrollar proyectos en areas tales como: geotecnia y geomecanica, hidrologia, geometria vial, arquitectura, instrumentacion, maquetas y animaciones virtuales.

RCQ

Page 8: Rcq ingenieria estructural  2013

Geothecnical Engineering.

Hidrology .

Road Design.

Arquitecture. 3D Virtual Modeling.

3D Animation Modeling.

O U R S E R V I C E S

Viaducts, Bridges, Footbridges, Aqueducts, Cantilever and anchored retaining walls.

Road infrastructure:

Steel Structures Precast Structures: reinforced concrete, prestresed concrete.

Special foundations.

Review and retrofit of structures.

Consulting and inspection at the construction stage.

Seismic protection of structures: seismic isolation, energy dissipation.

Special Structural Analisys: structural dynamics, non lineal analysis, soil-structure interaction, vibrations, steel and concrete fatigue.

Page 9: Rcq ingenieria estructural  2013

Infraestructura Vial: Viaductos, Puentes, Pasarelas, Acueductos, Muros de Contencion.

Estructuras Estructuras Prefabricadas: Hormigon Armado, Pretensado y Postensado.

Fundaciones Especiales.

Revisión, diagnóstico y rehabil itación estructural.

Asesoría e inspección etapa construccion.

Protección sísmica de Estructuras: aislación sísmica, disipación de energía. Análisis Especiales: dinámica estructural, vibraciones, fatigamiento de acero y hormigón.

Ingeniería geotécnica.

Hidrología.Diseño Geométrico de caminos.

Arquitectura.Maquetas virtuales 3D.

Animaciones virtuales 3D.

N U E S T R O S S E R V I C I O S

Page 10: Rcq ingenieria estructural  2013
Page 11: Rcq ingenieria estructural  2013

P R O J E C T SP R O Y E C T O S

Page 12: Rcq ingenieria estructural  2013
Page 13: Rcq ingenieria estructural  2013

A C C E S O P O N I E N T E

L E N G H T 3 8 7 M • L O N G I T U D 3 8 7 M

V I A D U C T

E A S T A C C E S S

V I A D U C T O

Page 14: Rcq ingenieria estructural  2013

This structure located over Costanera highway and Vespucio Avenue in Santiago, Chile, is 387 m long. Its deck is made of prestressed girders, steel box girders and lightened slab. This structure withstood a strong earthquake measuring 8.8 on February 27, 2010, with no damages whatsoever.

C L I E N TSACYR CHILE S.A

W O R K Structural Design

D E S C R I P T I O NLenght: 387 mHeight: 15 m

L O C A T I O NCentenary Intersection,

North West HighwaySantiago, Chile.

Y E A R2009

Page 15: Rcq ingenieria estructural  2013

C L I E N T ESACYR CHILE S.A

T R A B A J ODiseño Estructural

D E S C R I P C I Ó NLongitud 387 m. Contínuo

Altura máxima 14 m.

U B I C A C I Ó NNudo Centenario,Radial Nororiente, Santiago, Chile.

A Ñ O2009

Esta estructura emplazada sobre Costanera Norte y Americo Vespucio, posee una longitud de 387 m. El tablero lo conforman vigas pretensadas, vigas metálicas cajón y losas aligeradas. Esta estructura fue sometida al violento sismo del 27 de Febrero de 2010, magnitud 8.8 (mw), sin presentar daños.

Page 16: Rcq ingenieria estructural  2013

P I E R V I E WE L E V A C I Ó N F R O N T A L C E P A

Page 17: Rcq ingenieria estructural  2013

L I G H T E N E D S L A B C R O S S S E C T I O NS E C C I Ó N T R A N S V E R S A L L O S A A L I G E R A D A

C O M P O S I T E D E C K C R O S S S E C T I O NS E C C I Ó N L O S A T A B L E R O M I X T O

Page 18: Rcq ingenieria estructural  2013
Page 19: Rcq ingenieria estructural  2013
Page 20: Rcq ingenieria estructural  2013
Page 21: Rcq ingenieria estructural  2013

1 4 0 M T O P H E I G H T • A L T U R A M Á X I M A 1 4 0 M

THERMOELECTR IC PLANT PETROPOWER

REFUERZO SISMICO ESTRUCTURA - DERRICK UNIDAD DE COKER

PLANTA TERMOELECTRICA PETROPOWER

SE ISMIC RE INFORCEMENT - DERRICK UNIT COKER

Page 22: Rcq ingenieria estructural  2013

CLIENTEFOSTER WHEELER CHILE

TRABAJO Análisis Dinámico y Refuerzo Sísmico

DESCRIPCIÓNAltura Total 140 m

UBICACIÓNPlanta Termoeléctrica Petropower,

Talcahuano, VIII Región del Bío-Bío,

Chile.

AÑO2010

CLIENTFOSTER WHEELER CHILE

COMPANY

WORKDynamics Analysis andSeismic Reinforcement

DESCRIPTION140 m High

LOCATIONPetropower Thermoelectric Plant,

Talcahuano City, Chile.

YEAR2010

Page 23: Rcq ingenieria estructural  2013
Page 24: Rcq ingenieria estructural  2013

Esta estructura, parte de la unidad de coker fue dañada durante el terremoto de 2010, la cual estuvo a punto de colapsar. Para establecer las reparaciones requeridas fue necesario llevar a cabo análisis dinámicos que permitieran a la estructura resistir sin daño un terremoto similar al ocurrido. La estructura llamada “Derrick”, posee una altura de 72 m, y se encuentra soportada por una estructura de 23 m de alto, con un total de 95 m sobre el terreno.

This structure is part of the coker unit, it was damaged by the 8.8 magnitude earhtquake in 2010, being very near to collapse. It was necessary to performance a complete dynamic analysis to set the reinformcement requeride to resist an earthquake like in 2010. the Derrick structure has 72 m high and is supported by another structure of about 23 m height above ground, namely, 95 m high.

23 M

72 M

95 M

Page 25: Rcq ingenieria estructural  2013

SAP2000

SAP2000 v11.0.0 - File:Mod-3D-SI-Actual-0 - Deformed Shape (MODAL) - Mode 7 - Period 0,64911 - Ton, m, C Units

8-30-10 16:30:28SAP2000

SAP2000 v11.0.0 - File:Mod-3D-SI-Actual-0 - Deformed Shape (MODAL) - Mode 8 - Period 0,57238 - Ton, m, C Units

8-30-10 16:30:55

Page 26: Rcq ingenieria estructural  2013

C U R V E O V E R M A P O C H O R I V E R

B R I D G E

LENGHT 121 M • LONGITUD 121 M

C U R V O S O B R E E L M A P O C H O

P U E N T E

Page 27: Rcq ingenieria estructural  2013
Page 28: Rcq ingenieria estructural  2013
Page 29: Rcq ingenieria estructural  2013

C L I E N TINGENIERIA EL ALBA COMPANY

W O R K Structural Design

D E S C R I P T I O N4 Curved continuous span,

121 m lenghtPost-tensioned slab lightened

L O C A T I O NNorth West,

Santiago, Chile.

Y E A R2013

C L I E N T EINGENIERIA EL ALBA

T R A B A J O Diseño Estructural

D E S C R I P C I Ó N4 Vanos Contínuos

Longitud 121 mRadio de Corvatura 73 mTablero de losa Aligerada

Postensada

U B I C A C I Ó NCarretera Costanera Norte,

Lo Barnechea, Santiago, Chile.

A Ñ O2013

Page 30: Rcq ingenieria estructural  2013
Page 31: Rcq ingenieria estructural  2013

L A U N C H G I R D E R R E I N F O R C E M E N T • R E F U E R Z O V I G A S L A N Z A D O R A S

L I N E A 4

E L E V A T E D G U I D E W A Y

L I N E 4

V I A D U C T O D E M E T R O

Page 32: Rcq ingenieria estructural  2013

C L I E N T EVSL CHILE

T R A B A J OAnálisis y Refuerzo Sísmico de Vigas Lanzadoras

D E S C R I P C I Ó NVigas Lanzadoras para montaje de Dovelas Prefabricadas

U B I C A C I Ó NLinea 4 de Metro Elevado entre La Florida y Puente Alto.Santiago, Chile. Longitud de 18,3 Km.

A Ñ O2003

C L I E N TVSL CHILE

W O R KSeismic Reinforcement of Launch Girder

D E S C R I P T I O NSegmental Precast Spans placed by Launch Girders

L O C A T I O NElevated Guideway between locations of La Florida and Puente Alto. 18,3 Km long.Santiago, Chile

Y E A R2003

Page 33: Rcq ingenieria estructural  2013
Page 34: Rcq ingenieria estructural  2013

D E A L L A U N C H G I R D E R S E I S M I C D Y N A M I C S A N A L Y S I S

Page 35: Rcq ingenieria estructural  2013

V S L L A U N C H G I R D E R S E I S M I C D Y N A M I C S A N A L Y S I S

Page 36: Rcq ingenieria estructural  2013

D E P A R T A M E N T A LE L E V A T E D G U I D E W A Y / V I A D U C T O D E M E T R O

Page 37: Rcq ingenieria estructural  2013
Page 38: Rcq ingenieria estructural  2013

C L I E N T ECONSTRUCTORA NECSO-SACYR CHILE

T R A B A J OAnálisis Dinámico YDiseño infraestructura

D E S C R I P C I Ó NLongitud 167 mAltura máxima 10 m

U B I C A C I Ó NConcesión Vespucio Sur,Santiago, Chile.

A Ñ O2005

C L I E N TCONSTRUCTORA NECSO-SACYR CHILE

W O R KDynamics analysis and Infrastructure design D E S C R I P T I O NLenght: 167 mHeight: 10 m

L O C A T I O NVespucio South Highway Santiago, Chile

Y E A R2005

Page 39: Rcq ingenieria estructural  2013

STAT ION CROSS SECT ION / SECCION T RANVERSAL ES T ACIÓN

Page 40: Rcq ingenieria estructural  2013
Page 41: Rcq ingenieria estructural  2013

4 9 M H E I G H T • A L T U R A P U E N T E 4 9 M

E L B O S Q U E D E S A N T I A G O

V I A D U C T

T H E F O R E S T O F S A N T I A G O

V I A D U C T O

Page 42: Rcq ingenieria estructural  2013

Currently, this structure is the highest urban bridge in Chile. The main girders were placed by launch girders. Its performance at the 8.8 magnitude earthquake in 2010 was without any damage whatsoever.

C L I E N TSACYR CHILE S.A

W O R K Design

D E S C R I P T I O NLenght: 261 mHeight: 50 m

L O C A T I O NNorth West Highway,

Santiago, Chile.

Y E A R2009

Page 43: Rcq ingenieria estructural  2013

C L I E N T ESACYR CHILE S.A

T R A B A J ODiseño

D E S C R I P C I Ó NLongitud 261 m. Contínuo

Altura máxima 50 m

U B I C A C I Ó NRadial Nororiente,Santiago, Chile.

A Ñ O2009

El Viaducto el Bosque de Santiago, corresponde a la estructura vial urbana mas alta de Chile. Las vigas pretensadas del tablero fueron montadas mediante viga lanzadora (freyssinet). Esta estructura fue sometida al violento sismo del 27 de Febrero de 2010, magnitud 8.8 (mw), sin sufrir daños.

Page 44: Rcq ingenieria estructural  2013
Page 45: Rcq ingenieria estructural  2013
Page 46: Rcq ingenieria estructural  2013
Page 47: Rcq ingenieria estructural  2013

A M E R I C O V E S P U C I O

S E I S M I C I S O L A T I O N • A I S L A C I Ó N S Í S M I C A

V I A D U C T / V I A D U C T O

Page 48: Rcq ingenieria estructural  2013

This structure has a particular geometry (''Y” shape), being the first concessioned bridge with seismic insolation and the second one in Chile, to also include seismic isolation expansion joints (swivel-joist type). Its seismic performance at the 8.8 Magnitude earthquake in 2010 was without any damage whatsoever.

CLIENTSACYR CHILE S.A

WORK Structural Design

DESCRIPTIONSeismic isolation

Long: 184 m High: 6m

LOCATION North West Highway,

Santiago,Chile.

YEAR

2009

Page 49: Rcq ingenieria estructural  2013

C L I E N T ESACYR CHILE S.A

T R A B A J ODiseño Estructural

D E S C R I P C I Ó NLongitud 184 m Contínuo

Altura máxima 16 mAsilación Sísmica

U B I C A C I Ó NNudo Centenario, Radial Nororiente,Santiago, Chile.

A Ñ O2009

Esta estructura posee una singular geometria en Y, constituyendo el primer puente concesionado con aislacion sísmica y el segundo en Chile, incorporando ademas juntas de dilatación sísmicas tipo travesaño giratorio. El Puente fue sometido al violento sismo del 27 de febrero de 2010, magnitud 8.8 (mw), sin presentar daños.

Page 50: Rcq ingenieria estructural  2013

COMPOSITE DECK CROSS SECTIONESQUEMA TABLERO MIXTO

LIGHTENED SLAB CROSS SECTIONSECCIÓN LOSA ALIGERADA

Page 51: Rcq ingenieria estructural  2013

ELASTIC DESIGN SPECTRA FOR SOIL TYPE I / ESPECTROS DE DISEÑO ELÁSTICO PARA SUELO TIPO I

No IsolationSin Aislación

With IsolationCon Aislación

VerticalVertical

Page 52: Rcq ingenieria estructural  2013
Page 53: Rcq ingenieria estructural  2013
Page 54: Rcq ingenieria estructural  2013
Page 55: Rcq ingenieria estructural  2013

L A S C A N T E R A SV I A D U C T / V I A D U C T O

Page 56: Rcq ingenieria estructural  2013

C L I E N T ESACYR CHILE S.A

T R A B A J ODiseño Estructural

D E S C R I P C I Ó NLongitud 2 x 151 m ContínuoAltura máxima 25 m

U B I C A C I Ó NRadial Nororiente,Santiago, Chile.

A Ñ O2009

C L I E N TSACYR CHILE S.A

W O R KStructural Design

D E S C R I P C T I O NLenght: 2x151 m(Continuous deck)Height: 25 m

L O C A T I O NNorth West HighwaySantiago, Chile.

Y E A R2009

Page 57: Rcq ingenieria estructural  2013
Page 58: Rcq ingenieria estructural  2013

The bridge deck was made of concrete slab supported on 4 prestressed girders. The Piers were made by a huge table support over a 2.5 m circular Hollow column. Its seismic performance at the 8.8 magnitude earthquake in 2010 was without any damage whatsover.

El tablero se estructura con lasa de hormigón apoyada sobre 4 vigas pretensadas. Las cepas se conforman por un gran dintel apoyado sobre columna hueca circular de 2.5 m de diámetro. Esta estructura fue sometida al violento sismo del 27 de febrero de 2010, magnitud 8.8 (Mw), sin presentar daños.

Page 59: Rcq ingenieria estructural  2013
Page 60: Rcq ingenieria estructural  2013
Page 61: Rcq ingenieria estructural  2013
Page 62: Rcq ingenieria estructural  2013
Page 63: Rcq ingenieria estructural  2013

E M B A L S E L A C I G Ü E N AV I A D U C T / V I A D U C T O

Page 64: Rcq ingenieria estructural  2013
Page 65: Rcq ingenieria estructural  2013

C L I E N T EESTRUCTURAS VIALES S.A

T R A B A J OAnálisis Dinámico y

Diseño infraestructural

D E S C R I P C I Ó NLongitud 200 m

Altura máxima 21 m

U B I C A C I Ó NConcesión Ruta Costera,

Cartagena,Chile.

A Ñ O2002

Esta estructura posee un longitud total de 210 m con tablero continuo conformado por vigas pretensadas. Fue sometido al violento sísmico de 2010 (Mw=8.8), sin presentar daños.

C L I E N TROAD STRUCTURES CO

W O R KDynamic Analysis and Infrastructure Design

D E S C R I P T I O NLength: 200 m Height: 21 m

L O C A T I O NCoastal Road,

Cartagena City, Chile.

Y E A R2002

This structure has 210 m of continuous deck, which is made by a concrete slab on prestressed girders. Its performance at the 8.8 magnitude earthquake on 2010 was without damage whatsover.

Page 66: Rcq ingenieria estructural  2013

PUENTE SEMI INTEGRAL MÁS LARGO DE CHILE

I B A Ñ E ZB R I D G E / P U E N T E

LONGEST SEMI INTEGRAL BRIDGE (CHILE)

JOINTLESS BRIDGE

Page 67: Rcq ingenieria estructural  2013
Page 68: Rcq ingenieria estructural  2013
Page 69: Rcq ingenieria estructural  2013

C L I E N T ESACYR CHILE S.A

T R A B A J OAnálisis Dinámico y Cinemático,

Diseño Estructural

D E S C R I P C I Ó NPuente Semi Integral más largo

de Chile Longitud 80 m

U B I C A C I Ó NConcepción, Chile.

A Ñ O2013

C L I E N TSACYR CHILE S.A

W O R KDynamics and Cinematic Analysis,

Structural Design

D E S C R I P T I O NLongest Semi-integral bridge in

ChileLong: 80 m

L O C A T I O NConcepción, Chile.

Y E A R2013

Measures in meterMedidas en metros

Page 70: Rcq ingenieria estructural  2013
Page 71: Rcq ingenieria estructural  2013

8 5 M H E I G H T • A L T U R A 8 5 M

P L A N T A T E R M O E L É C T R I C A D E M E J I L L O N E S

WIND DYNAMICS EFFECTS ON PROCESS CHIMNEY

EFECTO DINAMICO DEL VIENTO EN CHIMENEA DE PROCESOS

M E J I L L O N E ' S T H E R M O E L E C T R I C P L A N T

Page 72: Rcq ingenieria estructural  2013

CLIENTEFOSTER WHEELER CHILE

TRABAJO Estudio Efectos Dinámicos del Viento

DESCRIPCIÓNAltura total 85 m. Material : Acero

UBICACIÓNCentral Térmica de Mejillones

Antofagasta, Chile.

AÑO2010

CLIENTFOSTER WHEELER CHILE

WORKDynamic Wind Effects on Process

Chimeney

DESCRIPTIONHeight: 85 m Type : Steel

LOCATIONMejillones Power Plant

Antofagasta, Chile.

YEAR2010

Page 73: Rcq ingenieria estructural  2013
Page 74: Rcq ingenieria estructural  2013
Page 75: Rcq ingenieria estructural  2013

C A R T A G E N AV I A D U C T / V I A D U C T O

Page 76: Rcq ingenieria estructural  2013
Page 77: Rcq ingenieria estructural  2013

C L I E N T EESTRUCTURAS VIALES S.A

T R A B A J OAnálisis Dinámico Y

Diseño infraestructural

D E S C R I P C I Ó NLongitud 236.5 m

Altura máxima 54.3 m

U B I C A C I Ó NConcesión Ruta Costera,

Cartagena, Chile.

A Ñ O2002

C L I E N TROAD STRUCTURES CO

W O R KDynamics analysis and

Infrastructure design

D E S C R I P T I O NLenght: 237 m

Height: 55 m

L O C A T I O NCoastal Road.

Cartagena, Chile

Y E A R2002

The Bridge deck is made with the highest prestressed girders built in Chile (2.5 m). It is 54.3 m high and 236.5 m long (continuous deck). Its performance at the 8.8 magnitude earthquake in2010 was without damage whatsover.

El Viaducto Cartagena, ubicado en la ruta costera que une Algarrobo y Cartagena, incorpora en su tablero las vigas pretensadas de mayor canto fabricadas en Chile (2.5 m). Posee una altura máxima 54.3 m y una longitud continua de 236.5 m. Esta estructura fue sometida al violento sismo del 27 de febrero de 2010, magnitud 8.8 (mw).

Page 78: Rcq ingenieria estructural  2013
Page 79: Rcq ingenieria estructural  2013

C E N T E N A R I OB R I D G E / P U E N T E

2009 ICRI AWARD OF MERIT • PREMIO AL MERITO, ICRI 2009

Page 80: Rcq ingenieria estructural  2013

CLIENTSACYR CHILE S.A.

The Centenary bridge, located above the Mapocho river in Santiago, was widened to incorporate a fourth traffic lane over the lateral cantilevers. To give enough resistance to those cantilevers, they were reinforced with FRP technique. Because of this Reinforcement, the INTERNATIONAL CONCRETE REPAIR INSTITUTE gave us the award of merit at the transportation category in 2009.

BEFORE/ANTES

DESCRIPTIONCantilever reinforcement

with FRP

WORKFEM

Analysis

LOCATIONNorth West Highway,

Santiago, Chile.

YEAR 2009

Page 81: Rcq ingenieria estructural  2013

C L I E N T ESACYR CHILE S.A.

El Puente Centenario, ubicado sobre el rio Mapocho en Santiago, fue ampliado de 3 a 4 pistas con el objetivo de aumentar su capacidad de tránsito. Esta ampliación implicó remover los pasillos laterales sobre los voladizos, y realizar su refuerzo mediante bandas de fibra de carbono, constituyendo la aplicación más relevante en este tipo de tecnologias. El año 2009, el instituto de reparaciones de EEUU (ICRI), otorgó el premio al merito a este novedoso proyecto.

T R A B A J OModelos Elementos finitos y

Análisis tensional

D E S C R I P C I Ó NRefuerzo Voladizos exteriores con FRP

U B I C A C I Ó N Radial Nororiente,

Santiago, Chile

A Ñ O2009

AFTER/ACTUAL

Page 82: Rcq ingenieria estructural  2013

F I S C A LB R I D G E / P U E N T E

AISLACIONSISMICA • SEISMICISOLATION

Page 83: Rcq ingenieria estructural  2013

C L I E N TSACYR CHILE S.A.

W O R KDynamics Analysis including

Seismic Isolation and Structural Design

D E S C R I P T I O NBridge with Seismic Isolators

and Swivel Modular JointLenght: 180 m

L O C A T I O NLa Serena city,

Chile.

Y E A R 2013

C L I E N T ESACYR CHILE S.A.

T R A B A J OAnálisis Dinámico con

Aislación Sísmica y Diseño Estructural

D E S C R I P C I Ó N

Aislación sísmica y Juntas de Travesaño Giratorio.

Longitud 180 m.

U B I C A C I Ó NLa Serena,

Chile.

A Ñ O2013

Page 84: Rcq ingenieria estructural  2013
Page 85: Rcq ingenieria estructural  2013

M A R G A M A R G A

HEIGHEST BRIDGE WITH PRESTRESSED GIRDERS (CHILE). TOP HEIGHT: 60 MPUENTE CON VIGAS PRETENSADAS MÁS ALTO DE CHILE. ALTURA MÁX. 60 M

V I A D U C T / V I A D U C T O

Page 86: Rcq ingenieria estructural  2013

This Bridge deck include the Highest Prestressed Girders manufactured in Chile (2.5 m). Besides, we have ins-talled Seismic Swivel Joints for the first time. Its structural performance at the 8.8 magnitude earthquake in 2010 was without any damage whatsoever.

C L I E N TCONSTRUCTURA ACS SACYR CHILE

T R A B A J OStructural Consultancy at stage

construction

D E S C R I P C T I O NLength: 300 mHeight: 60 m

L O C A T I O NConcession South trunk,

Quilpué, Chile.

C O N S T R U C T I O N Y E A R2009

Page 87: Rcq ingenieria estructural  2013

Esta estructura cuenta con las vigas de mayor canto fabricadas en Chile (2.5 m), siendo el Puente con tablero de vigas pretensadas más alto de Chile. Su comportamiento durante el sismo de 200 fue sin daños. Además, por primera vez en Chile se instalaron Juntas sísmicas de Travesaño Giratorio.

C L I E N T ECONSTRUCTURA ACS SACYR CHILE

T R A B A J OAsesoría estructural etapa

construcción

D E S C R I P C I Ó NLongitud 300 m

Altura máxima 60 m

U B I C A C I Ó NConcesión troncal sur,

Quilpué, Chile.

A Ñ O2009

Page 88: Rcq ingenieria estructural  2013
Page 89: Rcq ingenieria estructural  2013
Page 90: Rcq ingenieria estructural  2013

F R O I L A N R O AU N D E R P A S S / P A S O I N F E R I O R

Page 91: Rcq ingenieria estructural  2013

C L I E N TNECSO-SACYR CHILE

COMPANY

W O R KStructural Design

D E S C R I P T I O NIntegral Bridge,

45.7 m longPost-tenssioned Lightened Slab

L O C A T I O NVespucio South Highway

Santiago,Chile.

Y E A R2003

C L I E N T ENECSO-SACYR CHILE

T R A B A J ODiseño Estructural

D E S C R I P C I Ó NPuente Integral de

losa aligerada postensada

Longitud 45.7 m

U B I C A C I Ó NConcesión

Vespucio SurSantiago, Chile.

A Ñ O2003

Page 92: Rcq ingenieria estructural  2013
Page 93: Rcq ingenieria estructural  2013

WINDTURBINEOF1.5MWAND80MHIGH • AEREOGENERADOR1.5MWY80MDEALTURA

E O L I C P A R KWIND TURBINE FOUNDATIONS/FUNDACIONES AEROGENERADORES

Page 94: Rcq ingenieria estructural  2013

CLIENTESECTOR ENERGÍAS RENOVABLES

TRABAJO Diseño de Fundaciones Directas y Piloteadas

DESCRIPCIÓNAltura Total 85/95 mPotencia 1.4/3.0 MW.Material: Acero

UBICACIÓNParque Eólico,Norte de Chile

CLIENTRENEWABLE ENERGY

WORKDeep and Shallow foundations design

DESCRIPTIONHeight 85 M/ 95 mPower 1.4/3.0 MW.Material: Steel

LOCATIONEolic Park, North of Chile

Page 95: Rcq ingenieria estructural  2013

CLASS 1CLASE 1

8500

Page 96: Rcq ingenieria estructural  2013
Page 97: Rcq ingenieria estructural  2013

SPREAD FOOTING WIND TURBINEFUNDACIONES AEROGENERADOR / 95 M ALTURA

CLASS 2CLASE 2

Page 98: Rcq ingenieria estructural  2013

T R O N G O LB R I D G E / P U E N T E

Page 99: Rcq ingenieria estructural  2013

C L I E N T ECONSTRUCTORA

RUTA160 S.A

T R A B A J ODiseño

D E S C R I P C I Ó NLongitud 65 m

Altura máxima 16.2 m

U B I C A C I Ó NConseción Coronel-3

PinosArauco, Chile.

A Ñ O2011

C L I E N TRUTA 160

CONSTRUCTION

W O R KDesign

D E S C R I P T I O NLenght: 65 m

Height: 16.2 m

L O C A T I O NCoronel - tres pinos

HighwayArauco, Chile.

Y E A R2011

Page 100: Rcq ingenieria estructural  2013

B R I D G E / P U E N T EH U A S C O

A D V A N C E D C O N C E P T U A L D E S I G NDISEÑO CONCEPCTUAL AVANZADO

Page 101: Rcq ingenieria estructural  2013
Page 102: Rcq ingenieria estructural  2013
Page 103: Rcq ingenieria estructural  2013

C L I E N T ESACYR CHILE S.A

T R A B A J ODiseño estructural

nivel anteproyecto avanzado

D E S C R I P C I Ó NLongitud 200 m

Altura máxima 30 mVano central 108 M

Arco de acero con tablero superior

U B I C A C I Ó NConcesión Ruta 5,

tramo Vallenar-caldera, Chile.

A Ñ O2011

C L I E N TSACYR CHILE S.A

W O R KStructural Design

Advanced conceptual design

D E S C R I P T I O NLenght: 200 m Height: 30 m

Central span: 108 mSteel Arch with top deck

steel arch top board steel arch top boardL O C A T I O N

5 south highway, road Vallenar-caldera,

Chile.

Y E A R2011

Page 104: Rcq ingenieria estructural  2013
Page 105: Rcq ingenieria estructural  2013

C O N F L U E N C I AB R I D G E / P U E N T E

Page 106: Rcq ingenieria estructural  2013

This structure is located at the “El Teniente” Division of Codelco, in Chile. It was designed to resist heavy mining traffic and 4 major water pipings. Besides, include seis-mic isolators and Modular seismic Joint. It is 151 m long and 30 m high.

C L I E N TCODELCO CHILE COMPANY

W O R KStructural Design

D E S C R I P T I O NLenght: 154 m4 steel girdersHeight: 29 m

Seismic Isolation

L O C A T I O N"El Teniente" Division,

Chile.

Y E A R2011

Page 107: Rcq ingenieria estructural  2013

C L I E N T ECODELCO CHILE

T R A B A J ODiseño Estructural

D E S C R I P C I Ó NLongitud 154 m.

4 vigas metálicas Altura máxima. 29 m.

Aislación Sísmica

U B I C A C I Ó NDivisión El Teniente de Codelco,

Chile.

A Ñ O2011

Esta estructura, ubicada en la División El Teniente en Chile, permite el tránsito vehicular pesado de minería, así como el transporte de agua por medio de 4 tuberías. Además, incorpora aisladores sísmicos, y juntas de dilatación modulares. Posee una longitud de 151 m de tablero continuo, y una altura de 30 m sobre río Coya.

Page 108: Rcq ingenieria estructural  2013
Page 109: Rcq ingenieria estructural  2013
Page 110: Rcq ingenieria estructural  2013
Page 111: Rcq ingenieria estructural  2013

C O M P O S I T E D E C K C R O S S S E C T I O N / S E C C I O N T R A N S V E R S A L T A B L E R O

Page 112: Rcq ingenieria estructural  2013

R A M A D I L L A SV I A D U C T / V I A D U C T O

Page 113: Rcq ingenieria estructural  2013

C L I E N T ECONSTRUCTORA 160 S.A

T R A B A J ODiseño

D E S C R I P C I Ó NLongitud 280 m

Altura máxima 10 m

U B I C A C I Ó NConseción Coronel-3 Pinos,

Chile

A Ñ O2011

C L I E N TRUTA 160 CONSTRUCTION

W O R KDesign

D E S C R I P T I O NLength: 280 m

Height: 10 m

L O C A T I O NCoronel - tres pinos Highway,

Chile

Y E A R2011

Page 114: Rcq ingenieria estructural  2013
Page 115: Rcq ingenieria estructural  2013

R U T A 5 N O R T EU N D E R P A S S / P A S O S U P E R I O R

PUENTE SEMI-INTEGRAL • JOINTLESS BRIDGE

Page 116: Rcq ingenieria estructural  2013

This Under Pass, it is a Semi Integral bridge type, with no joint. During the 8.8 magnitude earthquake in 2010, the access embankments and the footbridge next to the bridge were collapsed. However, the bridge was in service all the time without structural damage whatsoever.

CLIENTSACYR CHILE S.A

WORKStructural Design

DESCRIPTIONLenght 57m

Semi-integral

LOCATION North West Highway

Santiago, Chile

YEAR

2009

Page 117: Rcq ingenieria estructural  2013

Este Paso Superior, posee la tipología Semi integral, sin juntas de dilatación. Durante el Terremoto de 2010, los terraplenes de acceso, así como la pasarela adyacente colapsaron; sin embargo, el puente resistió sin daños estructurales, permaneciendo en todo momento operativo.

C L I E N T ESACYT CHILE S.A

T R A B A J ODiseño Estructural

D E S C R I P C I Ó NLongitud 57mSemi-integral

U B I C A C I Ó NConcesión Acceso Nororiente

Santiago de Chile

A Ñ O2009

Page 118: Rcq ingenieria estructural  2013

J U A N S O L D A D OB R I D G E / P U E N T E

SEISMIC ISOLATION / AISLACION SISMICA

Page 119: Rcq ingenieria estructural  2013

C L I E N TSACYR CHILE S.A

W O R KDynamics Analysis including

Seismic Isolation and Structural Design

D E S C R I P T I O NBridge with Seismic Isolators

and Swivel Modular JointLenght 160 /Hight 38 m

L O C A T I O NLa Serena City, Chile.

Y E A R 2013

C L I E N T ESACYR CHILE S.A

T R A B A J OAnálisis Dinámico con

Aislación Sísmica y Diseño Estructural

D E S C R I P C I Ó NAislación Sísmica tipo Caucho

natural con núcleo de plomo y Juntas de Travesaño

GiratorioLongitud 160 m

Altura 38 m

U B I C A C I Ó NLa Serena, Chile.

A Ñ O2013

Page 120: Rcq ingenieria estructural  2013

L R B I S O L A T O R ( L E A D R U B B E R B E A R I N G )A I S L A D O R L R B

Page 121: Rcq ingenieria estructural  2013

F R O N T A L P I E R V I E WE L E V A C I Ó N F R O N T A L C E P A

37.70 M

Page 122: Rcq ingenieria estructural  2013

A L E S S A N D R IO V E R P A S S / P A S O I N F E R I O R

SEMI - INTEGRAL OVER PASS (JOINTLESS)

Page 123: Rcq ingenieria estructural  2013

C L I E N TDRAGADOS

W O R KStructural Design

D E S C R I P T I O NLenght: 70.7 m

semi-integral

L O C A T I O N5 South Highway,

Puerto Montt - Pargua Road Chile.

Y E A R

2011

C L I E N T EDRAGADOS

T R A B A J ODiseño Estructural

D E S C R I P C I Ó NLongitud 70.7 m.

semi-integral

U B I C A C I Ó NConcesión Ruta 5 Sur

Puerto Montt - ParguaX Región, Chile.

A Ñ O2011

Page 124: Rcq ingenieria estructural  2013
Page 125: Rcq ingenieria estructural  2013

www.rcqingenieria.cl

Page 126: Rcq ingenieria estructural  2013
Page 127: Rcq ingenieria estructural  2013

C L I E N T E SC L I E N T S

Page 128: Rcq ingenieria estructural  2013

©All rights reserved©Todos los derechos reservados

Page 129: Rcq ingenieria estructural  2013

RCQ STRUCTURAL ENGINEERINGRCQ INGENIERÍA ESTRUCTURAL

Octubre 2013October 2013

Powered by•RealizaciónMansarda Estudio

Edited by•Responsable del ProyectoFrancisco Bedwell Campos

Graphic Desing•Diseño GráficoMansarda Estudio

Layout•MaquetaciónOrielli Domínguez

Translation•TraducciónHI END LEARNING

Picture•FotografíaRCQ Ingeniería Estructural

Render•Imágenes 3DFrancisco Bedwell Campos

Post Edition•Post EdiciónOrielli Domínguez

Page 130: Rcq ingenieria estructural  2013