Rates - mk0acecwimf55vfrtbrb.kinstacdn.com · MC6 Coincident demand billed firm (no load control)...
Transcript of Rates - mk0acecwimf55vfrtbrb.kinstacdn.com · MC6 Coincident demand billed firm (no load control)...
1
TABLE OF CONTENTS
RATE CODE DESCRIPTIONS ......................................................................................................2
RATE CODE DESCRIPTIONS (continued)...................................................................................3
RATE DESCRIPTIONS (continued) ..............................................................................................4
RATE SCHEDULE AVAILABILITY AND DISCLAIMER .........................................................5
GENERAL SINGLE-PHASE, FARM & RESIDENTIAL SERVICE............................................6
GENERAL SERVICE TIME-OF-DAY (TOD) ..............................................................................7
DAIRY FARM SERVICE ...............................................................................................................8
ELECTRIC SPACE HEATING ......................................................................................................9
ELECTRIC SPACE HEATING TIME-OF-DAY (TOD) .............................................................11
INTERRUPTIBLE - DUAL FUEL ELECTRIC SPACE HEATING ...........................................13
COMMERCIAL SERVICE (3ϕ) ...................................................................................................15
COMMERCIAL SERVICE (3ϕ) TIME-OF-DAY (TOD) ............................................................16
LARGE POWER SERVICE..........................................................................................................17
LARGE POWER SERVICE (OVER 1000 KVA) ........................................................................19
LARGE POWER ECONOMIC DEVELOPMENT (OVER 10,000 KVA) ..................................20
LARGE POWER SERVICE – TIME-OF-DAY (TOD) ...............................................................21
IRRIGATION SERVICE - NO ACEC CONTROL ......................................................................23
IRRIGATION SERVICE NO ACEC CONTROL - COINCIDENT ............................................25
IRRIGATION SERVICE OFF PEAK – ACEC CONTROLLED ................................................27
YARD LIGHT RENTAL FACILITIES ........................................................................................29
STREET LIGHT RENTAL FACILITIES .....................................................................................30
RENEWABLE GENERATION RATE – CLOSED RATE ..........................................................31
RENEWABLE GENERATION RATE – CLOSED RATE ..........................................................32
RENEWABLE GENERATION RATE – CLOSED RATE ..........................................................33
RENEWABLE GENERATION RATE .........................................................................................34
Effective dates referenced in this document indicate that the rate will be effective for all invoices
prepared on or after this date, regardless of the period being billed.
2
ADAMS-COLUMBIA ELECTRIC COOPERATIVE Rate Descriptions
Friendship, Wisconsin Effective: 9/8/14
RATE CODE DESCRIPTIONS
Type Rate Code Description Page
Residential 21 Single-phase service for full-time residential use. For accounts
with maximum demand less than 40kW.
6
Residential
TOD
T1 Single-phase time-of-day (TOD) service for full-time residential
use.
7
Residential
Resistance Heat
E1H Second-meter electric service for electric resistant heat (only) for
full-time residential use.
9
Residential
Resistance Heat
(plus)
X1H Second-meter electric service for electric resistant heat (only) for
full-time residential use where other loads have been added to the
second meter service.
9
Residential
Resistance Heat
TOD
H1T Second-meter electric service for time-of-day (TOD) electric
resistant heat (only) for full-time residential use.
11
Residential
Resistance Heat
TOD (plus)
X1T Second-meter electric service for time-of-day (TOD) electric
resistant heat (only) for full-time residential use where other loads
have been added to the second meter service.
11
Residential
Interruptible
Resistance Heat
I1H Sub-metered second-meter electric service for interruptible
electric resistant heat (only) for full-time residential use in a home
that has back up fossil fuel heat. This Is A Closed Rate (not
available for new connects)
13
Residential
Interruptible
Resistance Heat
J1H Second-meter electric service for interruptible electric resistant
heat (only) for full-time residential use in a home that has back up
fossil fuel heat.
13
General
Service
42 Single-phase service for non-full-time residential (second homes,
cottages) use, including sheds, garages, outbuildings, town halls,
churches, stock waterers and camper services). For accounts with
maximum demand less than 40kW.
6
General
Service TOD
T2 Single-phase time-of-day (TOD) service for non-full-time
residential (second homes, cottages) use, including sheds,
garages, outbuildings, town halls, churches, stock waterers and
camper services.
7
General
Service
Resistance Heat
E2H Second-meter electric service for electric resistant heat (only) for
a home for non-full-time residential (second homes, cottages) use.
9
General
Service
Resistance Heat
(plus)
X2H Second-meter electric service for electric resistant heat (only) for
non-full-time residential (second homes, cottages) use where
other loads have been added to the second meter service.
9
General
Service
Resistance Heat
TOD
H2T Second-meter electric service for time-of-day (TOD) electric
resistant heat (only) for non-full-time residential (second homes,
cottages) use.
11
3
ADAMS-COLUMBIA ELECTRIC COOPERATIVE Rate Descriptions
Friendship, Wisconsin Effective: 9/8/14
RATE CODE DESCRIPTIONS (continued)
Type Rate Code Description Page
Residential
Seasonal
Resistance Heat
TOD (plus)
X2T Second-meter electric service for time-of-day (TOD) electric
resistant heat (only) for non-full-time residential (second homes,
cottages) use where other loads have been added to the second
meter service.
11
Residential
Seasonal
Interruptible
Resistance Heat
J2H Second-meter electric service for interruptible electric resistant
heat (only) for non-full-time residential (second homes, cottages)
use in a home that has back up fossil fuel heat.
13
Dairy Farm DF Single- or three-phase service for dairy farm accounts with
maximum demand less than 40kW.
8
Small
Commercial
23 Single-phase service for commercial accounts with maximum
demand less than 40kW. Includes services like convenience
stores, small businesses, county parks, campgrounds, billboards,
grain dryers and irrigation pivot-only.
6
Small
Commercial
TOD
T3 Single-phase time-of-day (TOD) service for non-residential
accounts with maximum demand less than 40kW. Includes
services like convenience stores, small businesses, county parks,
campgrounds, billboards, grain dryers and irrigation pivot-only.
7
Small
Commercial
Resistance Heat
E3H Second-meter single-phase electric service for electric resistant
heat (only) for commercial accounts.
9
Small
Commercial Resist. Heat (plus)
X3H Second-meter single-phase electric service for electric resistant
heat (only) for commercial accounts where other loads have been
added to the second meter service.
9
Small
Commercial Resist. Heat TOD
H3T Second-meter single-phase electric service for time-of-day (TOD)
electric resistant heat (only) for non-residential accounts.
11
Small
Commercial
Interruptible
Resistance Heat
J3H Second-meter single-phase electric service for interruptible
electric resistant heat (only) for non-residential accounts that have
back up fossil fuel heat. Includes services like billboards, and
irrigation pivot-only services.
13
Commercial 34 Three-phase electric service for non-residential accounts with
maximum demand less than 40kW
15
Commercial
TOD
34T Three-phase time-of-day (TOD) electric service for non-
residential accounts with maximum demand less than 40kW
16
Large Power 63 Single-phase electric service for large commercial services with
maximum demand of 40kW or more. Demand (KW) is billed
17
Large Power
Resistance Heat
E4H Second-meter three-phase electric service for electric resistant
heat (only) in a large commercial establishment.
9
Large Power Resistance Heat TOD
H4T Second-meter three-phase electric service for time-of-day (TOD)
electric resistant heat (only) for a large commercial establishment.
11
4
ADAMS-COLUMBIA ELECTRIC COOPERATIVE Rate Descriptions
Friendship, Wisconsin Effective: 1/1/17
RATE DESCRIPTIONS (continued)
Type Rate Code Description Page
Large Power
Interruptible
Resistance Heat
J4H Second-meter three-phase electric service for interruptible electric
resistant heat (only) for a large commercial establishment that has
back up fossil fuel heat.
13
Large Power 64 Three-phase electric service for large commercial services with
maximum demand of 40kW or more. Demand (kW) is billed.
17
Large Power
TOD
EBR Single- and three-phase non-irrigation time-of-day (TOD) electric
service. For accounts with maximum demand of 40kW or more.
21
Industrial Various
Three-phase electric service for very large commercial services
(requiring transformer capacity of 1000 kVA or more).
19
Industrial Economic
Development Rate Various
Three-phase electric service for very large commercial services
(requiring transformer capacity of 10,000 kVA or more).
20
Irrigation M6 Firm (no load control) irrigation service for farm irrigation pumps
of 15 HP and greater, billed 12 monthly facility charges.
23
Irrigation M66 Firm (no load control) irrigation service for farm irrigation pumps
of 15 HP and greater, billed 6 monthly facility charges but same
annual facility charges as M6.
23
Irrigation Experimental Rate Only – Not Open
MC6
Coincident demand billed firm (no load control) irrigation service
for farm irrigation pumps of 15 HP and greater, billed 12 monthly
facility charges.
25
Irrigation Experimental Rate Only
– Not Open
MC66
Coincident demand billed firm (no load control) irrigation service
for farm irrigation pumps of 15 HP and greater, billed 6 monthly
facility charges but same annual facility charges as M6.
25
Irrigation N6 Controlled irrigation service for non-farm irrigation pumps of 15
HP and greater, billed 12 monthly facility charges.
27
Irrigation N66 Controlled irrigation service for non-farm irrigation pumps of 15
HP and greater, billed 6 monthly facility charges but same annual
facility charges as N6.
27
Irrigation P6 Controlled irrigation service for farm irrigation pumps of 15 HP
and greater, billed 12 monthly facility charges.
27
Irrigation P66 Controlled irrigation service for farm irrigation pumps of 15 HP
and greater (billed 6 monthly facility charges but same annual facility charges as P6)
27
Yard Light YL Available to all members for lighting yards and other areas. 29
Street Light SL Available to Townships, unincorporated municipalities and select
members for lighting of streets, parking lots, etc.
30
Renewable
Generation
RGS Closed Rate
For members receiving service with renewable energy facilities
not greater than 20 kW connected in parallel with ACEC.
31
Renewable
Generation
RGL Closed Rate
For members receiving service with renewable energy facilities
greater than 20 kW capacity connected in parallel with ACEC.
32
Renewable
Generation
RG Closed Rate
For members receiving service with renewable energy facilities
connected in parallel with ACEC (demand & energy billed, two meters).
33
Renewable
Generation
RG1 For members receiving service with renewable energy facilities
connected in parallel with ACEC (energy billed, one meter).
34
5
RATE SCHEDULE AVAILABILITY AND DISCLAIMER
The availability of a Rate Schedule for a member is based on the member meeting
qualifications of the availability clause and other terms of the Rate Schedule. Rate
Schedules are available upon request and it shall be the member’s responsibility to
see that he/she is charged the rate for which he/she qualifies. In some cases the
member may be eligible to take service under more than one rate.
By request the Cooperative will advise the member in the selection of the rate that
will give him/her the lowest cost of service based on information provided to the
Cooperative; however, the responsibility for the selection of the rate lies with the
member. After the member has selected the rate under which he/she elects to take
service, or when the type or capacity of service(s) needed requires a change to
another rate, the member will not be permitted to change from that rate to another
rate until at least 12 months have elapsed. An exception to this elapsed time
requirement will be made if the service no longer meets the availability clause of the
Rate Schedule. Additionally, it is the responsibility of the member to notify the
Cooperative of any change that affects the rate or charge for service.
No refund will be made of the difference in charges under different rates applicable
to the same class of service.
(Source – ACEC Service Rules and Regulations)
Adams-Columbia Electric Cooperative provides Internet access to
our rate schedules for the convenience of our membership. While we
strive to keep these documents up to date, please note that the rate
schedules and details included therein are subject to change at the
discretion of the Cooperative’s board of directors. Users should note
that the schedules provided on this web site are not the official
documents and users assume responsibility for reliance upon rate
schedules in electronic format. Please contact the Cooperative with
any questions you may have.
6
ADAMS-COLUMBIA ELECTRIC COOPERATIVE Rate Codes 21, 23, 42
Friendship, Wisconsin Effective: 4/6/18
Rate Schedule: GS
GENERAL SINGLE-PHASE, FARM & RESIDENTIAL SERVICE
1. AVAILABILITY
Available to all single-phase accounts whose measured maximum demands for eleven (11) of
the past twelve (12) months has been less than 40 kW. Service is subject to the established
rules and regulations of the Cooperative.
2. TYPE OF SERVICE
Single-phase, 60 cycles at available secondary voltage
3. RATE
Facility Charge: $ 1.08 per day
Energy Charge: All energy @ 11.2 ¢ per kWh
4. MINIMUM MONTHLY BILL
The facility charge specified above, except where multiple units are served.
(See ACEC Policy #11-3).
5. POWER COST ADJUSTMENT CHARGE
Any adjustment in the Cooperative’s energy cost per kilowatt-hour in accordance with
changes in the Cooperative’s wholesale power cost will be added to or deducted from the
member’s current bill for electric service as appropriate.
6. TERMS OF PAYMENT
The above rates are net. Bills not paid by the due date are subject to a late payment charge
on the unpaid balance in accordance with the Cooperative’s Service Rules & Regulations.
7. TAXES AND FEES
The State of Wisconsin, County and local sales taxes, Non-Taxable Program Fees, and any
other legislative or regulatory fees imposed by governmental agencies will be applied to each
billing for electric services as applicable.
8. OTHER FEES
Additional charges may be added to the Facility Charge for members requiring easement
payments, line crossing charges, insurance charges or any other charge that a member may
impose on the Cooperative. These fees will be prorated to a monthly basis and added to the
Basic Facility Charge.
7
ADAMS-COLUMBIA ELECTRIC COOPERATIVE Rate Codes T1, T2, T3
Friendship, Wisconsin Effective: 4/6/18
Rate Schedule: GS-TOD
GENERAL SERVICE TIME-OF-DAY (TOD)
1. AVAILABILITY
Available to members for all single-phase uses whose measured maximum demands for
eleven (11) of the past twelve (12) months has been less than 40 kW. The capacity of
individual motors served under this schedule shall not exceed 10 HP without prior approval
of the Cooperative. Service is subject to the established rules and regulations of the
Cooperative.
2. TYPE OF SERVICE
Single-phase, 60 cycles at available secondary voltages.
3. RATE
Facility Charge: $1.08 per day
Energy Charge: On-Peak @ 25.8¢ per kWh
Off-Peak @ 7.1¢ per kWh
On-Peak:
November 1 - April 30: 5:00 p.m. to 8:00 p.m.
Monday through Friday, except Holidays
May 1 – October 31: 1:00 p.m. to 8:00 p.m.
Monday through Friday, except Holidays
Off-Peak: All other hours
4. MINIMUM CHARGE
The minimum monthly charge under the above rate shall be the calculated facility charge
noted above, except where multiple units are served. (See ACEC Policy #11-3).
5. POWER COST ADJUSTMENT CHARGE
Any adjustment in the Cooperative’s energy cost per kilowatt-hour in accordance with the
Cooperative’s wholesale power bill power cost will be added to or deducted from the
member’s current bill for electric service as appropriate.
6. TERMS OF PAYMENT
The above rates are net. Bills not paid by the due date are subject to a late payment charge
on the unpaid balance in accordance with the Cooperative’s Service Rules & Regulations.
7. TAXES AND FEES
The State of Wisconsin, County and local sales taxes, Non-Taxable Program Fees, and any
other legislative or regulatory fees imposed by governmental agencies will be applied to each
billing for electric services as applicable.
8
ADAMS-COLUMBIA ELECTRIC COOPERATIVE Rate Code DF
Friendship, Wisconsin Effective: 4/6/18
Rate Schedule: DF
DAIRY FARM SERVICE
1. AVAILABILITY
Available to all active dairy farms whose measured maximum demand for eleven (11) of the
past twelve (12) months has been less than 40kW. Service is subject to the established rules
and regulations of the Cooperative.
2. TYPE OF SERVICE
Single-phase and three-phase at available secondary voltage.
3. RATE
Facility Charge: $ 1.08 per day
Energy Charge: All energy @ 11.2¢ per kWh
4. MINIMUM MONTHLY BILL
The minimum charge shall be the calculated facility charge noted above, except where
multiple units are served. (See ACEC Policy #11-3)
5. POWER COST ADJUSTMENT CHARGE
Any adjustment in the Cooperative’s energy cost per kilowatt-hour in accordance with
changes in the Cooperative’s wholesale power cost will be added to or deducted from the
member’s current bill for electric service as appropriate.
6. TERMS OF PAYMENT
The above rates are net. Bills not paid by the due date are subject to a late payment charge
on the unpaid balance in accordance with the Cooperative’s Service Rules & Regulations.
7. TAXES AND FEES
The State of Wisconsin, County and local sales taxes, Non-Taxable Program Fees, and any
other legislative or regulatory fees imposed by governmental agencies will be applied to each
billing for electric services as applicable.
8. CONDITIONS OF SERVICE
A. Dairy farms on this rate must be active dairy producing operations listed with the WI
Department of Agriculture.
B. Active dairy farms whose measured maximum demand for two (2) or more of the past
twelve (12) months has been equal to or greater than 40 kW will be billed under the
LP-1 rate.
9
ADAMS-COLUMBIA ELECTRIC COOPERATIVE Rate Codes E1H, E2H, E3H, E4H,
Friendship, Wisconsin X1H, X2H, X3H
Effective: 4/6/18
Rate Schedule: EH
ELECTRIC SPACE HEATING
1. AVAILABILITY
Available to all members who use separately metered electric energy for heating, conforming
to the specifications set forth hereunder, and who are receiving service at the same location for
other usages. Service is subject to the established rules and regulations of the Cooperative.
2. TYPE OF SERVICE
Single- or three-phase, 60 cycles at available secondary voltage, separately metered.
3. RATE
Facility Charge: $8.50 per month (second meter charge)
Energy Charge: All energy @ 10.5¢ per kWh (September – May billing periods)
All energy @ 15.7¢ per kWh (June – August billing periods)
All energy @ 11.2¢ per kWh all months for X1H, X2H, and X3H
rate codes.
4. MINIMUM CHARGE
The minimum monthly charge under above rate shall be the facility charge noted above.
5. POWER COST ADJUSTMENT CHARGE
Any adjustment in the Cooperative’s energy cost per kilowatt-hour in accordance with changes
in the Cooperative’s wholesale power cost will be added to or deducted from the member’s
current bill for electric service as appropriate.
6. TERMS OF PAYMENT
The above rates are net. Bills not paid by the due date are subject to a late payment charge on
the unpaid balance in accordance with the Cooperative’s Service Rules & Regulations.
7. CONDITIONS OF SERVICE
A. The member shall provide the complete service entrance according to the
Cooperative’s specifications necessary for the separate electric heat meter.
B. Space heating equipment shall be permanently connected and as far as practicable,
shall be 240 volt.
C. The minimum connected heating load shall be 5000 watts resistance-type heat.
D. Not more than 6000 watts of resistance-type space heating equipment shall be
controlled by a single thermostat or manually operated switch.
10
ADAMS-COLUMBIA ELECTRIC COOPERATIVE Rate Codes E1H, E2H, E3H, E4H,
Friendship, Wisconsin X1H, X2H, X3H
Effective: 4/6/18
Rate Schedule: EH
ELECTRIC SPACE HEATING
Page 2 of 2
E. Electric water heaters may not be connected to this service.
F. Supplemental resistance heating in heat pumps may be included on this rate.
G. Central heating systems such as electric furnace and systems that include air
conditioning will not be permitted on this rate; however, Schedule GS-TOD is
available.
8. TAXES AND FEES
The State of Wisconsin, County and local sales taxes, Non-Taxable Program Fees, and any
other legislative or regulatory fees imposed by governmental agencies will be applied to each
billing for electric services as applicable.
9. NON-COMPLIANCE (X1H, X2H, and X3H rate codes)
Members who had load on their electric heat panel that did not comply with the conditions of
this rate were transferred to the X rate until the non-complying load is removed.
11
ADAMS-COLUMBIA ELECTRIC COOPERATIVE Rate Codes H1T, H2T,
Friendship, Wisconsin H3T, H4T, X1T, X2T
Effective: 4/6/18
Rate Schedule: EH-TOD
ELECTRIC SPACE HEATING TIME-OF-DAY (TOD)
1. AVAILABILITY
Available to all members who use separately metered electric energy for heating, conforming
to the specifications set forth hereunder, and who are receiving service at the same location
for other usages. Service is subject to the established rules and regulations of the
Cooperative.
2. TYPE OF SERVICE
Single- and three-phase, 60 cycles at available secondary voltage, separately metered.
3. RATE
Facility Charge: $8.50 per month (second meter charge)
Energy Charges: On-Peak @ 24.6¢ per kWh
On-Peak @ 25.8¢ per kWh for X1T and X2T rate codes
Off-Peak @ 6.8¢ per kWh (September – May billing periods)
Off-Peak @ 15.7¢ per kWh (June – August billing periods)
Off-Peak @ 7.1¢ per kWh all months for X1T and X2T rate codes
On-Peak:
November 1 – April 30: 5:00 p.m. to 8:00 p.m.
Monday through Friday, except Holidays
May 1 – October 31: 1:00 p.m. to 8:00 p.m.
Monday through Friday, except Holidays
Off-Peak: All other hours
4. POWER COST ADJUSTMENT CHARGE
Any adjustment in the Cooperative’s energy cost per kilowatt-hour in accordance with
changes in the Cooperative’s wholesale power cost will be added to or deducted from the
member’s current bill for electric service as appropriate.
5. MINIMUM CHARGE
The minimum monthly charge under above rate shall be the facility charge noted above.
6. TERMS OF PAYMENT
The above rates are net. Bills not paid by the due date are subject to a late payment charge
on the unpaid balance in accordance with the Cooperative’s Service Rules & Regulations.
7. CONDITIONS OF SERVICE
A. The member shall provide the complete service entrance according to the
Cooperative’s specifications necessary for the separate electric heat meter.
B. The member shall permanently install and operate approved type electric heating
equipment.
C. Electric water heaters may not be connected to this service.
12
ADAMS-COLUMBIA ELECTRIC COOPERATIVE Rate Codes H1T, H2T,
Friendship, Wisconsin H3T, H4T, X1T, X2T
Effective: 04-6-18
Rate Schedule: EH-TOD
ELECTRIC SPACE HEATING
TIME-OF-DAY (TOD)
Page 2 of 2
8. TAXES AND FEES
The State of Wisconsin, County and local sales taxes, Non-Taxable Program Fees, and any
other legislative or regulatory fees imposed by governmental agencies will be applied to each
billing for electric services as applicable.
9. NON-COMPLIANCE (X1T and X2T rate codes)
Members who had load on their electric heat panel that did not comply with the conditions of
this rate were transferred to the time-of-day X rate until the non-complying load is removed.
13
ADAMS-COLUMBIA ELECTRIC COOPERATIVE Rate Codes I1H, I4H, J1H,
Friendship, Wisconsin J2H, J3H, J4H
Effective: 4/6/18
Rate Schedule: EH-I
INTERRUPTIBLE - DUAL FUEL ELECTRIC SPACE HEATING
1. AVAILABILITY
Restricted to areas of the Cooperative that have load management capabilities. Available to
all members in these areas who use separately metered electric energy for heating,
conforming to the specifications set forth hereunder, and who are receiving service at the
same location for other usages. Service is subject to the established rules and regulations of
the Cooperative.
2. TYPE OF SERVICE
Single- or three-phase, 60 cycles at available secondary voltage, separately metered.
3. RATE
Facility Charge: $8.50 per month (second meter charge)
Energy Charge: All energy @ 6.8¢ per kWh (September – May billing periods)
Energy Charge: All energy @ 15.7¢ per kWh (June – August billing periods)
4. POWER COST ADJUSTMENT CHARGE
Any adjustment in the Cooperative’s energy cost per kilowatt-hour in accordance with changes
in the Cooperative’s wholesale power cost will be added to or deducted from the member’s
current bill for electric service as appropriate.
5. MINIMUM CHARGE
The minimum monthly charge under above rate shall be the facility charge noted above.
6. TERMS OF PAYMENT
The above rates are net. Bills not paid by the due date are subject to a late payment charge
on the unpaid balance in accordance with the Cooperative’s Service Rules & Regulations.
7. CONDITIONS OF SERVICE
A. The member shall provide the complete service entrance according to the
Cooperative’s specifications necessary for the separate electric heat meter.
B. The member shall permanently install and operate electric home heating equipment in
conjunction with an oil or gas-fired central furnace as approved by this Cooperative. If
member wishes to use wood backup or no backup they must supply the Cooperative
with a liability waiver.
C. The electric service to the electric heat shall be interrupted during peak load periods.
D. Electric water heaters may not be connected to this service.
E. Supplemental resistance electric heat in heat pumps may be included on this rate.
14
ADAMS-COLUMBIA ELECTRIC COOPERATIVE Rate Codes I1H, I4H, J1H,
Friendship, Wisconsin J2H, J3H, J4H
Effective: 04-6-18
Rate Schedule: EH-I
INTERRUPTIBLE - DUAL FUEL
ELECTRIC SPACE HEATING
Page 2 of 2
F. Systems that include air conditioning will not be allowed on this rate; however,
schedule GS-TOD is available.
8. TAXES AND FEES
The State of Wisconsin, County and local sales taxes, Non-Taxable Program Fees, and any
other legislative or regulatory fees imposed by governmental agencies will be applied to each
billing for electric services as applicable.
15
ADAMS-COLUMBIA ELECTRIC COOPERATIVE Rate Code 34
Friendship, Wisconsin Effective: 4/6/18
Rate Schedule: PS
COMMERCIAL SERVICE (3ϕ)
1. AVAILABILITY
Available to all three-phase accounts (excluding irrigation pumping) whose measured
maximum demand for eleven (11) of the past twelve (12) months has been less than 40 kW.
Service is subject to the established rules and regulations of the Cooperative.
2. TYPE OF SERVICE
Three-phase, 60 cycles at available secondary voltage
3. RATE
Facility Charge: $2.00 per day
Energy Charge: All energy @ 11.2¢ per kWh
4. MINIMUM MONTHLY BILL
The facility charge specified above, except where multiple units are served. (See ACEC
Policy #11-3)
5. POWER COST ADJUSTMENT CHARGE
Any adjustment in the Cooperative’s energy cost per kilowatt-hour in accordance with
changes in the Cooperative’s wholesale power cost will be added to or deducted from the
member’s current bill for electric service as appropriate.
6. TERMS OF PAYMENT
The above rates are net. Bills not paid by the due date are subject to a late payment charge
on the unpaid balance in accordance with the Cooperative’s Service Rules & Regulations.
7. TAXES AND FEES
The State of Wisconsin, County and local sales taxes, Non-Taxable Program Fees, and any
other legislative or regulatory fees imposed by governmental agencies will be applied to each
billing for electric service as applicable.
8. OTHER FEES
Additional charges may be added to the Facility Charge for members requiring easement
payments, line crossing charges, insurance charges or any other charge that a member may
impose on the Cooperative. These fees will be prorated to a monthly basis and added to the
Basic Facility Charge.
16
ADAMS-COLUMBIA ELECTRIC COOPERATIVE Rate Code 34T
Friendship, Wisconsin Effective: 4/6/18
Rate Schedule: PS-TOD
COMMERCIAL SERVICE (3ϕ) TIME-OF-DAY (TOD)
1. AVAILABILITY
Available to all three-phase accounts (excluding irrigation pumping) whose measured
maximum demand for eleven (11) of the past twelve (12) months has been less than 40 kW.
Service is subject to the established rules and regulations of the Cooperative.
2. TYPE OF SERVICE
Three-phase, 60 cycles at available secondary voltage
3. RATE
Facility Charge: $2.00 per day
Energy Charge: On-Peak @ 33.7¢ per kWh
Off-Peak @ 7.9¢ per kWh
On-Peak:
November 1 – April 30: 5:00 p.m. to 8:00 p.m.
Monday through Friday, except Holidays
May 1 – October 31: 1:00 p.m. to 8:00 p.m.
Monday through Friday, except Holidays
Off-Peak: All other hours
4. MINIMUM MONTHLY BILL
The facility charge specified above, except where multiple units are served.
(See ACEC Policy #11-3)
5. POWER COST ADJUSTMENT CHARGE
Any adjustment in the Cooperative’s energy cost per kilowatt-hour in accordance with
changes in the Cooperative’s wholesale power cost will be added to or deducted from the
member’s current bill for electric service as appropriate.
6. TERMS OF PAYMENT
The above rates are net. Bills not paid by the due date are subject to a late payment charge
on the unpaid balance in accordance with the Cooperative’s Service Rules & Regulations.
7. TAXES AND FEES
The State of Wisconsin, County and local sales taxes, Non-Taxable Program Fees, and any
other legislative or regulatory fees imposed by governmental agencies will be applied to each
billing for electric service as applicable.
8. OTHER FEES
Additional charges may be added to the Facility Charge for members requiring easement
payments, line crossing charges, insurance charges or any other charge that a member may
impose on the Cooperative. These fees will be prorated to a monthly basis and added to the
Basic Facility Charge.
17
ADAMS-COLUMBIA ELECTRIC COOPERATIVE Rate Codes 63, 64
Friendship, Wisconsin Effective: 4/8/19
Rate Schedule: LP-1
LARGE POWER SERVICE
1. AVAILABILITY
For all single and three-phase non-irrigation accounts;
A. Whose measured maximum demands for two (2) or more of the past twelve (12)
months has been equal to or greater than 40 kW.
B. New accounts whose measured demands are estimated to be 40 kW or more shall
be placed on this rate until we have twelve (12) months of historical measured
demand readings.
C. For accounts that have twelve (12) consecutive months where the measured
maximum demand is less than 40 kW the Cooperative may transfer the account to
the GS or PS rate, whichever is appropriate.
D. This rate is available to any single- or three-phase non-irrigation account of less
than 40 kW peak demand, at the member’s request.
E. This rate is not available to accounts requiring 1000 kVA or more of transformer
capacity.
F. Service is subject to the established rules and regulations of the Cooperative.
2. TYPE OF SERVICE
Single-phase and three-phase, 60 cycles at available secondary voltage.
3. RATE
Facility Charge: $68.00 per month
Demand Charge: $21.38 per kW maximum demand
Energy Charge: All kWh @ 4.7¢ per kWh
4. POWER FACTOR CHARGE – At the Option of the Cooperative
20.0¢ per kVAR of maximum monthly reactive demand.
5. MINIMUM CHARGE
The minimum monthly charge is the facility charge.
6. DETERMINATION OF BILLING DEMAND
The billing demand for the month shall be the maximum recorded fifteen (15) minute demand
in kilowatts.
7. POWER COST ADJUSTMENT CHARGE
Any adjustment in the Cooperative’s energy cost per kilowatt-hour in accordance with
changes in the Cooperative’s wholesale power cost will be added to or deducted from the
member’s current bill for electric service as appropriate.
18
ADAMS-COLUMBIA ELECTRIC COOPERATIVE Rate Codes 63, 64
Friendship, Wisconsin Effective: 4/8/19
Rate Schedule: LP-1
LARGE POWER SERVICE
Page 2 of 2
8. TERMS OF PAYMENT
The above rates are net. Bills not paid by the due date are subject to a late payment charge
on the unpaid balance in accordance with the Cooperative’s Service Rules & Regulations.
9. TAXES AND FEES
The State of Wisconsin, County and local sales taxes, Non-Taxable Program Fees, and any
other legislative or regulatory fees imposed by governmental agencies will be applied to each
billing for electric services as applicable.
10. OTHER FEES
Additional charges may be added to the Facility Charge for members requiring easement
payments, line crossing charges, insurance charges or any other charge that a member may
impose on the Cooperative. These fees will be prorated to a monthly basis and added to the
Basic Facility Charge.
19
ADAMS-COLUMBIA ELECTRIC COOPERATIVE Rate Codes: ALS, BRK, ENB, FCI,
Friendship, Wisconsin GLO, HRT, KOC, MCN, UNI & UWGP
Effective: 4/8/19
Rate Schedule: LP-2
LARGE POWER SERVICE (OVER 1000 KVA)
1. AVAILABILITY
Available to all three-phase accounts requiring 1,000 kVA or more of transformer capacity. Service
is subject to the established rules and regulations of the Cooperative.
2. TYPE OF SERVICE
Three-phase, 60 cycles at available secondary voltage
3. RATE
Facility Charge: Based on cost of facilities installed by ACEC on a per
facility basis.
Firm Demand Charge: $ 25.83 per kW per month, measured at the time of
ACEC’s power supply coincident peak
Interruptible Demand Charge: $ 21.38 (special contract required)
Energy Charge: On-peak - all kWh @ 4.7¢ per kWh
Off-peak - all kWh @ 3.3¢ per kWh
On-Peak Period: 8 am – 10 pm Monday-Friday, except Holidays
Off-Peak: All other hours
4. POWER FACTOR CHARGE - At the option of the Cooperative
20.0¢ per kVAR of maximum monthly reactive demand.
5. MINIMUM CHARGE
A. The minimum monthly charge is the facility charge.
B. The minimum annual charge shall be five (5) times the maximum demand charge during the
year.
6. DETERMINATION OF BILLING DEMAND
The billing demand for the month shall be the maximum recorded fifteen (15) minute demand in
kilowatts during the hour of ACEC’s power supply coincident peak.
7. POWER COST ADJUSTMENT CHARGE
Any adjustment in the Cooperative’s energy cost per kilowatt-hour, in accordance with changes in the
Cooperative’s wholesale power cost, will be added to or deducted from the member’s current bill for
electric service as appropriate.
8. TERMS OF PAYMENT
The above rates are net. Bills not paid by the due date are subject to a late payment charge on the
unpaid balance in accordance with the Cooperative’s Service Rules & Regulations.
9. TAXES AND FEES
The State of Wisconsin, County and local sales taxes, Non-Taxable Program Fees, and any other
legislative or regulatory fees imposed by governmental agencies will be applied to each billing for
electric services as applicable.
20
ADAMS-COLUMBIA ELECTRIC COOPERATIVE Rate Code ENB2
Friendship, Wisconsin Effective: 4/8/19
Rate Schedule: LP-ED
LARGE POWER ECONOMIC DEVELOPMENT (OVER 10,000 KVA)
1. AVAILABILITY
Available to all new three-phase accounts requiring 10,000 kVA or more of transformer
capacity for a period of three years from first billing. Service is subject to the established
rules and regulations of the Cooperative.
2. TYPE OF SERVICE
Three-phase, 60 cycles at available secondary voltage
3. RATE
Facility Charge: Based on cost of facilities installed by ACEC on a
per facility basis.
Firm Demand Charge: $ 25.83 per kW per month, measured at the time of
ACEC’s power supply coincident peak
Interruptible Demand Charge: $ 21.38 (special contract required)
Energy Charge: On-peak - all kWh @ 4.2¢ per kWh
Off-peak - all kWh @ 3.0¢ per kWh
On-Peak Period: 8 am – 10 pm Monday-Friday, except Holidays
Off-Peak: All other hours
4. POWER FACTOR CHARGE - At the option of the Cooperative
20.0¢ per kVAR of maximum monthly reactive demand.
5. MINIMUM CHARGE - The minimum monthly charge is the facility charge.
6. DETERMINATION OF BILLING DEMAND
The billing demand for the month shall be the maximum recorded fifteen (15) minute
demand in kilowatts during the hour of ACEC’s power supply coincident peak.
7. HIGH LOAD FACTOR CREDIT
A credit of $0.015 per kWhr will be provided for energy greater than 40% load factor (based on
the maximum 15-minute non-coincident peak demand of that month) in each month
8. POWER COST ADJUSTMENT CHARGE
Any adjustment in the Cooperative’s energy cost per kilowatt-hour, in accordance with
changes in the Cooperative’s wholesale power cost, will be added to or deducted from the
member’s current bill for electric service as appropriate.
9. TERMS OF PAYMENT
The above rates are net. Bills not paid by the due date are subject to a late payment charge
on the unpaid balance in accordance with the Cooperative’s Service Rules & Regulations.
10. TAXES AND FEES
The State of Wisconsin, County and local sales taxes, Non-Taxable Program Fees, and any
other legislative or regulatory fees imposed by governmental agencies will be applied to each
billing for electric services as applicable.
21
ADAMS-COLUMBIA ELECTRIC COOPERATIVE Rate Code EBR
Friendship, Wisconsin Effective: 4/8/19
Rate Schedule: LP – TOD
LARGE POWER SERVICE – TIME-OF-DAY (TOD)
1. AVAILABILITY
For all single and three-phase non-irrigation accounts requesting a Time-of-Day rate;
A. Whose measured maximum demands for two (2) or more of the past twelve (12)
months has been equal to or greater than 40 kW.
B. New accounts whose measured demands are estimated to be 40 kW or more shall
be placed on this rate until twelve (12) months of historical measured demand
readings are available.
C. For accounts that have twelve (12) consecutive months where the measured
maximum demand is less than 40 kW the Cooperative may transfer the account to
the GS or PS rate, whichever is appropriate.
D. This rate is not available to accounts requiring 1000 kVA or more of transformer
capacity.
E. Service is subject to the established rules and regulations of the Cooperative.
2. TYPE OF SERVICE
Single-phase and three-phase 60 cycles at available secondary voltage.
3. RATE
Facility Charge: $85.00 per month
Demand Charge: $ 25.83 per kW per month on-peak
$ 9.19 per kW per month off-peak
Energy Charge: On-peak - all kWh @ 4.95¢ per kWh
Off-peak - all kWh @ 3.13¢ per kWh
On-Peak Period:
November 1 – April 30: 5:00 p.m. to 8:00 p.m.
Monday through Friday, except Holidays
May 1 – October 31: 10:00 a.m. to 8:00 p.m.
Monday through Friday, except Holidays
Off-Peak:
All other hours
4. POWER FACTOR CHARGE – At the option of the Cooperative
20.0¢ per kVAR of maximum monthly reactive demand.
5. MINIMUM CHARGE
The minimum monthly charge is the facility charge.
22
ADAMS-COLUMBIA ELECTRIC COOPERATIVE Rate Code EBR
Friendship, Wisconsin Effective: 4/8/19
Rate Schedule: LP - TOD
LARGE POWER SERVICE – TIME-OF-DAY (TOD)
Page 2 of 2
6. DETERMINATION OF BILLING DEMAND
This shall be the maximum kilowatt demand established for any fifteen (15) consecutive
minutes recorded during the established on-peak period and off-peak period during the
month for which the bill is rendered, as indicated or recorded by a time-of-day demand
meter.
7. POWER COST ADJUSTMENT CHARGE
Any adjustment in the Cooperative’s energy cost per kilowatt-hour in accordance with
changes in the Cooperative’s wholesale power cost will be added to or deducted from the
member’s current bill for electric service as appropriate.
8. TERMS OF PAYMENT
The above rates are net. Bills not paid by the due date are subject to a late payment
charge on the unpaid balance in accordance with the Cooperative’s Service Rules &
Regulations.
9. TAXES AND FEES
The State of Wisconsin, County and local sales taxes, Non-Taxable Program Fees, and
any other legislative or regulatory fees imposed by governmental agencies will be applied
to each billing for electric services as applicable.
10. OTHER FEES
Additional charges may be added to the Facility Charge for members requiring easement
payments, line crossing charges, insurance charges or any other charge that a member
may impose on the Cooperative. These fees will be prorated to a monthly basis and
added to the Basic Facility Charge.
23
ADAMS-COLUMBIA ELECTRIC COOPERATIVE Rate Codes M6, M66
Friendship, Wisconsin Effective: 4/8/19
Rate Schedule: I-1
IRRIGATION SERVICE - NO ACEC CONTROL
1. AVAILABILITY
For all services serving irrigation pumps 15 HP and over, subject to the established rules and
regulations of the Cooperative including requirements for load management controls.
2. TYPE OF SERVICE
Three-phase three-wire, three-phase four-wire, and single-phase, at available secondary
voltages.
3. RATE
Facility Charge: $1,440 per year @ $120 per month for 12 months OR $240 per
month April through September.
Demand Charges: $36.83 per kW maximum demand
Energy Charges: All energy @ 4.0¢ per kWh
4. POWER COST ADJUSTMENT CHARGE
Any adjustment in the Cooperative’s energy cost per kilowatt-hour in accordance with
changes in the Cooperative’s wholesale power cost will be added to or deducted from the
member’s current bill for electric service as appropriate.
5. MINIMUM ANNUAL CHARGE
A. The minimum annual charge shall be the facility charge.
B. Where a system or land is leased and credit with the Cooperative has not been
established, a deposit equivalent to $25.00/kW of established demand shall be paid in
advance and applied to the October bill or refunded at the end of the season.
The maximum demand used by the system for prior years is to be used for this charge;
otherwise 80% of the installed horsepower will be considered the demand in kW.
C. Any balance due on the annual facility charge will be applied to the final bill if service
is discontinued prior to the end of the billing year.
6. POWER FACTOR
The member agrees to maintain unity power factor as nearly as practicable. Power factors
may be measured at any time. Should such measurements indicate that the power factor at
the time of the member’s maximum demand is less than 85%, the demand for billing
purposes shall be the demand as indicated or recorded by the demand meter, multiplied by
85%, and divided by the percent power factor.
24
ADAMS-COLUMBIA ELECTRIC COOPERATIVE Rate Codes M6, M66
Friendship, Wisconsin Effective: 4/8/19
Rate Schedule: I-1
IRRIGATION SERVICE – NO ACEC CONTROL
Page 2 of 2
7. BILLING YEAR AND COMBINED READINGS
Energy billing will continue throughout the year under the terms and conditions of this rate.
Facility charges shall be billed each month, or if the member chooses the facility charge can
be billed over six billing periods from April through September. In the case of cranberry
marshes and where facilities other than irrigation pumps are used, facility charges shall be
billed each month from April through March. Demand charges shall be billed whenever a
demand is recorded, except as noted herein.
8. MAXIMUM DEMAND
The maximum demand shall be the maximum kilowatt demand (subject to power factor
adjustment) established for any period of fifteen (15) consecutive minutes during the month
for which the bill is rendered as indicated or recorded by a demand meter.
9. TERMS OF PAYMENT
The above rates are net. Bills not paid by the due date are subject to a late payment charge
on the unpaid balance in accordance with the Cooperative’s Service Rules & Regulations.
10. TAXES AND FEES
The State of Wisconsin, County and local sales taxes, Non-Taxable Program Fees, and any
other legislative or regulatory fees imposed by governmental agencies will be added to each
monthly bill for electric service as applicable.
25
ADAMS-COLUMBIA ELECTRIC COOPERATIVE Rate Codes MC6, MC66
Friendship, Wisconsin Effective: 4/8/19
Rate Schedule: I-2
IRRIGATION SERVICE NO ACEC CONTROL - COINCIDENT
1. AVAILABILITY – EXPERIMENTAL RATE ONLY – NOT OPEN
For all services serving irrigation pumps 15 HP and over, subject to the established rules and
regulations of the Cooperative including requirements for load management controls.
2. TYPE OF SERVICE
Three-phase three-wire, three-phase four-wire, and single-phase, at available secondary
voltages.
3. RATE
Facility Charge: $1,440 per year @ $120 per month for 12 months OR $240 per
month April through September.
Demand Charges: $25.83 per kW demand measured at the time of ACEC’s power
supply coincident peak, and
$10.70 per kW maximum demand for distribution
Energy Charges: All energy @ 4.0¢ per kWh
4. POWER COST ADJUSTMENT CHARGE
Any adjustment in the Cooperative’s energy cost per kilowatt-hour in accordance with
changes in the Cooperative’s wholesale power cost will be added to or deducted from the
member’s current bill for electric service as appropriate.
5. MINIMUM ANNUAL CHARGE
A. The minimum annual charge shall be the facility charge.
B. Where a system or land is leased and credit with the Cooperative has not been
established, a deposit equivalent to $25.00/kW of established demand shall be paid in
advance and applied to the October bill or refunded at the end of the season.
The maximum demand used by the system for prior years is to be used for this charge;
otherwise 80% of the installed horsepower will be considered the demand in kW.
C. Any balance due on the annual facility charge will be applied to the final bill if service
is discontinued prior to the end of the billing year.
6. POWER FACTOR
The member agrees to maintain unity power factor as nearly as practicable. Power factors
may be measured at any time. Should such measurements indicate that the power factor at
the time of the member’s maximum demand is less than 85%, the demand for billing
purposes shall be the demand as indicated or recorded by the demand meter, multiplied by
85%, and divided by the percent power factor.
26
ADAMS-COLUMBIA ELECTRIC COOPERATIVE Rate Codes MC6, MC66
Friendship, Wisconsin Effective: 4/8/19
Rate Schedule: I-2
IRRIGATION SERVICE NO ACEC CONTROL - COINCIDENT
Page 2 of 2
7. BILLING YEAR AND COMBINED READINGS
Energy billing will continue throughout the year under the terms and conditions of this rate.
Facility charges shall be billed each month, or if the member chooses the facility charge can
be billed over six billing periods from April through September. In the case of cranberry
marshes and where facilities other than irrigation pumps are used, facility charges shall be
billed each month from April through March. Demand charges shall be billed whenever a
demand is recorded, except as noted herein.
8. DETERMINATION OF BILLING DEMANDS
The power supply portion of the billing demand for the month shall be the average of the
four fifteen (15) minute demands in kilowatts during the hour of ACEC’s power supply
coincident peak and the distribution portion of the billing demand shall be the maximum
kilowatt demand established for any period of fifteen (15) consecutive minutes during the
month for which the bill is rendered, as indicated or recorded by a demand meter. Both
demands are subject to power factor adjustment.
9. TERMS OF PAYMENT
The above rates are net. Bills not paid by the due date are subject to a late payment charge
on the unpaid balance in accordance with the Cooperative’s Service Rules & Regulations.
10. TAXES AND FEES
The State of Wisconsin, County and local sales taxes, Non-Taxable Program Fees, and any
other legislative or regulatory fees imposed by governmental agencies will be added to each
monthly bill for electric service as applicable.
27
ADAMS-COLUMBIA ELECTRIC COOPERATIVE Rate Codes N6, N66, P6, P66
Friendship, Wisconsin Effective: 4/6/18
Rate Schedule: I-3
IRRIGATION SERVICE OFF PEAK – ACEC CONTROLLED
1. AVAILABILITY
For all services serving irrigation pumps 15 HP and over, subject to the established rules and
regulations of the Cooperative including requirements for load management controls.
2. TYPE OF SERVICE
Three-phase three-wire, three-phase four wire, and single-phase, at available secondary
voltages.
3. RATE
Facility Charge: $1,440 per year @ $120 per month for 12 months, OR $240 per
month April through September.
Demand Charges: $10.70 per kW billed for distribution.
Energy Charges: All energy @ 4.0¢ per kWh
4. CONDITIONS OF SERVICE
ACEC may interrupt (control) load Monday through Friday, between 8:00 a.m. to 8:00 p.m.
5. POWER COST ADJUSTMENT CHARGE
Any adjustment in the Cooperative’s energy cost per kilowatt-hour, in accordance with the
changes in the Cooperative’s wholesale power cost, will be added to or deducted
from the member’s current bill for electric service as appropriate.
6. MINIMUM ANNUAL CHARGE
A. The minimum annual charge shall be the facility charge.
B. Where a system or land is leased, and credit with the Cooperative has not been
established, a deposit equivalent to $25.00/kW of established demand shall be paid in
advance and applied to the October bill or refunded at the end of the season. .
The maximum demand used by the system for prior years is to be used for this charge;
otherwise 80% of the installed horsepower will be considered the demand in kW.
C. Any balance due on the annual facility charge will be applied to the final bill if service is
discontinued prior to the end of the billing year.
28
ADAMS-COLUMBIA ELECTRIC COOPERATIVE Rate Codes N6, N66, P6, P66
Friendship, Wisconsin Effective: 4/6/18
Rate Schedule: I-3
IRRIGATION SERVICE RATE – ACEC CONTROLLED
Page 2 of 2
7. POWER FACTOR
The member agrees to maintain unity power factor as nearly as practicable. Power factors
may be measured at any time. Should such measurements indicate that the power factor at
the time of the member’s maximum demand is less than 85%, the demand for billing
purposes shall be the demand as indicated or recorded by the demand meter, multiplied by
85%, and divided by the percent power factor.
8. BILLING YEAR AND COMBINED READINGS
Energy billing will continue throughout the year under the terms and conditions of this rate.
Facility charges shall be billed each month, or if the member chooses the facility charge can
be billed over six billing periods from April through September. In the case of cranberry
marshes and where facilities other than irrigation pumps are used, facility charges shall be
billed each month from April through March. Demand charges shall be billed whenever a
demand is recorded, except as noted herein.
9. TERMS OF PAYMENT
The above rates are net. Bills not paid by the due date are subject to a late payment charge
on the unpaid balance in accordance with the Cooperative’s Service Rules & Regulations.
10. TAXES AND FEES
The State of Wisconsin, County and local sales taxes, Non-Taxable Program Fees, and any
other legislative or regulatory fees imposed by governmental agencies will be added to each
monthly bill for electric service as applicable.
29
ADAMS-COLUMBIA ELECTRIC COOPERATIVE Rate Code: YL
Friendship, Wisconsin Effective: 4/6/18
Rate Schedule: YL
YARD LIGHT RENTAL FACILITIES
1. AVAILABILITY
Available for all members on a monthly basis upon acceptance by the Cooperative of a
signed Yard Light Lease Agreement. Service is subject to the established rules and
regulations of the Cooperative.
2. RATE
A. $11.00 per month for a lamp controlled with an electric eye and installed on an existing
Cooperative pole.
B. Other charges and conditions according to the Cooperative’s Service Rules & Regulations
i. An additional monthly charge will be applied for a pole set solely for the yard
light ($1.75 – 30’ pole, $2.00 – 35’ pole).
ii. Service over 100 feet will be installed at an additional monthly charge for each
50-foot increment ($0.50 per extra 50 feet). Closed to installations after 4-6-18
iii. An additional monthly charge shall be made where secondary voltage is not
available and a transformer must be provided ($8.00).
iv. Non-standard units (i.e., longer pole or mast arm) may be installed at additional
cost ($0.50 – 6-10’ arm, $1.00 – 12-16’ arm, $1.00 – secondary ped). Closed to
installations after 4-6-18
v. Charges for wire and pole installation, road bores, secondary pedestals, primary
(12.5kV) facilities, tree trimming, star gazer shields, guy wires or any non-
standard units including longer mast arms will be billed up front, with payment
received prior to installation. Lights are installed on the ACEC side of the meter
only. Energy charges are included in the base rate.
3. TERMS OF PAYMENT
The above rates are net. Bills not paid by the due date are subject to a late payment charge
on the unpaid balance in accordance with the Cooperative’s Service Rules & Regulations.
4. TERMS OF CONTRACT
Three-year minimum, unless otherwise specified.
5. TAXES AND FEES
The State of Wisconsin, County and local sales taxes, Non-Taxable Program Fees, and any
other legislative or regulatory fees imposed by governmental agencies will be applied to each
billing for electric services as applicable.
6. REFERENCE
Yard Light Lease Agreement - ACEC Form 3.
30
ADAMS-COLUMBIA ELECTRIC COOPERATIVE Rate Code: SL
Friendship, Wisconsin Effective: 4/6/18
Rate Schedule: SL
STREET LIGHT RENTAL FACILITIES
1. AVAILABILITY
Available for townships, unincorporated municipalities and select members on a monthly
basis upon acceptance by the Cooperative of a signed Street Light Lease Agreement. Service
is subject to the established rules and regulations of the Cooperative.
2. RATE
A. All street lights will have lamps controlled with an electric eye and installed on an
existing Cooperative pole.
100 watt $11.00 per month
150 watt $11.75 per month
250 watt $12.75 per month
400 watt $17.75 per month
B. Other charges and conditions according to the Cooperative’s Service Rules & Regulations
i. An additional monthly charge will be applied for a pole set solely for the yard
light ($1.75 – 30’ pole, $2.00 – 35’ pole).
ii. Service over 100 feet will be installed at an additional monthly charge for each
50-foot increment ($0.50 per extra 50 feet). Closed to installations after 4-6-18
iii. An additional monthly charge shall be made where secondary voltage is not
available and a transformer must be provided ($8.00).
iv. Non-standard units (i.e., longer pole or mast arm) may be installed at additional
cost ($0.50 – 6-10’ arm, $1.00 – 12-16’ arm, $1.00 – secondary ped). Closed to
installations after 4-6-18
v. Charges for wire and pole installation, road bores, secondary pedestals, primary
(12.5kV) facilities, tree trimming, star gazer shields, guy wires or any non-
standard units including longer mast arms will be billed up front, with payment
received prior to installation.
vi. Lights are installed on the ACEC side of the meter only. Energy charges are
included in the base rate.
3. TERMS OF PAYMENT
The above rates are net. Bills not paid by the due date are subject to a late payment charge
on the unpaid balance in accordance with the Cooperative’s Service Rules & Regulations.
4. TERMS OF CONTRACT
Three-year minimum, unless otherwise specified.
5. TAXES AND FEES
The State of Wisconsin, County and local sales taxes, Non-Taxable Program Fees, and any
other legislative or regulatory fees imposed by governmental agencies will be applied to each
billing for electric services as applicable.
6. REFERENCE
Street Light Lease Agreement - ACEC Form 314
31
ADAMS-COLUMBIA ELECTRIC COOPERATIVE Rate Codes RGS21, RGS23, RGS42
Friendship, Wisconsin Effective: 4/1/16
Rate Schedule: RGS
RENEWABLE GENERATION RATE – CLOSED RATE
1. AVAILABILITY
This rate is closed. No new connects will be allowed under this rate; existing accounts may
remain under this rate until 3/31/26. See rate schedule RG. A member under this rate may
transfer to rate schedule RG at any time but may not return to this rate.
2. SERVICE CHARACTERISTICS
Alternating current, 60 Hertz at available voltages and standards of the Cooperative.
3. MONTHLY SALES RATE
The facility charge and energy rate for sales to the member shall be in accordance with the
rate schedule applicable to the class of service provided.
4. MONTHLY PURCHASE RATE – SMALL DISTRIBUTED RENEWABLES (S)
Total generating capacity not to exceed 20kW single-phase or three-phase.
Net energy billing may be used with reverse registration permitted - direct metering only.
The following rate shall apply when member generation exceeds use:
Energy Credit (payment to member): Shall be in accordance with the rate the member is
charged for the connected service. For generation connected to residential services the
general service rate schedule (GS) would apply.
5. FACILITY CHARGE
If a second meter or special metering is required to properly register renewable generation a
facility charge not less than the standard second meter charge, but sufficient to cover costs
will be applied.
6. TERMS OF PAYMENT
Payment of the fixed charge and for sales to the member will be in accordance with the rate
schedule applicable to the class of service provided. Routine payment to the member for sales
to the Cooperative will be made separately, except the Cooperative may credit payment for
purchases against any past due amounts owed the Cooperative
32
ADAMS-COLUMBIA ELECTRIC COOPERATIVE Rate Code RGL23, RGL64
Friendship, Wisconsin Effective: 4/1/16
Rate Schedule: RGL
RENEWABLE GENERATION RATE – CLOSED RATE
1. AVAILABILITY
This rate is closed. No new connects will be allowed under this rate; existing accounts may
remain under this rate until 3/31/26. See rate schedule RG1. A member under this rate may
transfer to rate schedule RG1 at any time but may not return to this rate.
2. SERVICE CHARACTERISTICS
Alternating current, 60 Hertz at available voltages and standards of the Cooperative.
3. MONTHLY SALES RATE
The energy rate for sales to the member shall be in accordance with the rate schedule
applicable to the class of service provided.
4. MONTHLY PURCHASE RATE – LARGE DISTRIBUTED RENEWABLES (L)
Total generating capacity greater than 20kW.
The following rate shall apply when member generation exceeds use:
Energy Credit (payment to member): Generation supply cost
Capacity Credit (payment to member meeting qualification): LP-2 demand charge (coincident)
5. FACILITY CHARGE
Any interconnection and special metering costs not paid as aid-to-construction will be
recovered through a facility charge sufficient to cover Cooperative’s costs.
6. CAPACITY CREDIT QUALIFICATION
The monthly capacity factor of the member’s generator exceeds 70% during the Cooperative
power supplier on-peak energy periods over each of the prior 12 months.
7. TERMS OF PAYMENT
Payment of the fixed charge and for sales to the member will be in accordance with the rate
schedule applicable to the class of service provided. Routine payment to the member for sales
to the Cooperative will be made separately, except the Cooperative may credit payment for
purchases against any past due amounts owed the Cooperative
33
ADAMS-COLUMBIA ELECTRIC COOPERATIVE Rate Codes RG21, RG23, RG42, RG64
Friendship, Wisconsin Effective: 4/8/19
Rate Schedule: RG
RENEWABLE GENERATION RATE – CLOSED RATE
1. AVAILABILITY
Available to all members with qualified renewable energy conversion system facilities
connected in parallel with the Cooperative’s electric system.
2. SERVICE CHARACTERISTICS
Alternating current, 60 Hertz at available voltages and standards of the Cooperative.
3. MONTHLY RATE FOR SALES TO MEMBER
Facility Charge See below (for first meter on site)
See below (for second meter on site)
Power Supply Demand Charge: $25.83 per kW per month, measured for the hour of
ACEC’s power supply coincident peak
Distribution Demand Charge: $6.70 per kW per month of measured maximum
hourly demand.
Energy Charge: On-peak - all kWh @ 4.7¢ per kWh
Off-peak - all kWh @ 3.3¢ per kWh
4. MONTHLY PURCHASE RATE
The following rates shall apply when member supplies renewable generation to ACEC:
Facility Charge: See below
Power Supply Capacity (Credit): $25.83 per kW per month, measured for the hour of
ACEC’s power supply coincident peak
Distribution Capacity (Credit): $6.70 per kW per month of measured hourly demand
at the time ACEC’s distribution system peaks for
kW amount consistently available (currently 0 for solar).
Energy (Credit): On-peak - all kWh @ 4.7¢ per kWh
Off-peak - all kWh @ 3.3¢ per kWh
5. FACILITY CHARGE
A two meter installation will typically be required (when member has load to be served that is
separate from the requirements of the generation facility such as for a home or other building
on the property). If the member has only one meter at the energy conversion system service
point, however, the facility charge shall be the same as the first meter charge for the
residential rate class, unless such metering is insufficient and commercial service metering is
required, in which case the facility charge will be equal to the commercial or large power rate
class, as appropriate. When a second meter is used at a member location it shall be used for
the generation facility, and the facility charge for the second meter will be not less than the
standard second meter charge, but sufficient to cover the Cooperative’s costs.
6. TERMS OF PAYMENT
Payment of the fixed charge and for sales to the member will be in accordance with the rate
schedule shown above. Payment to the member for sales to the Cooperative will be identified
separately on the bill on the same bill cycle as for the load; the Cooperative may credit
payment for purchases against use by member at other locations or against any past due
amounts owed the Cooperative.
34
ADAMS-COLUMBIA ELECTRIC COOPERATIVE Rate Code RG121, RG123, RG142, RG164
Friendship, Wisconsin Effective: 4/6/18
Rate Schedule: RG1
RENEWABLE GENERATION RATE
1. AVAILABILITY
Available to all members with qualified renewable energy conversion system facilities
connected in parallel with the Cooperative’s electric system.
2. SERVICE CHARACTERISTICS
Alternating current, 60 Hertz at available voltages and standards of the Cooperative.
3. MONTHLY SALES RATE
The facility charge and energy rate for sales to the member shall be in accordance with the
rate schedule applicable to the class of service provided.
4. MONTHLY PURCHASE RATE
The following rate shall apply at any time member generation exceeds use:
Energy Credit (payment to member): Generation Supply Cost * 1.2
The Generation Supply Cost is the average cost of energy that ACEC paid to Alliant Energy
over the period of October 1 – September 30th of the prior year as shown in Attachment 4 of
ACEC’s Rules and Regulations.
5. FACILITY CHARGE
Any interconnection and special metering costs above the standard for the appropriate rate
schedule applicable to the class of service provided will be charged to the member as aid-to-
construction.
6. TERMS OF PAYMENT
Payment of the fixed charge and for sales to the member will be in accordance with the rate
schedule applicable to the class of service provided. Routine payment to the member for sales
to the Cooperative will be made separately, except the Cooperative may credit payment for
purchases against any past due amounts owed the Cooperative.